3003s Regulador Honda
3003s Regulador Honda
3003s Regulador Honda
40.2
Built-in constant current type overcurrent, overvoltage and thermal protection circuits
0.5
7.9 0.2
TO-220 equivalent full-mold package
16.9 0.3
a
2 max
Absolute Maximum Ratings b 2.6 0.15
(Ta =25C)
Parameter Symbol Ratings Unit Conditions
(13.5)
+0.2
2 0.85 0.1
Output current IO 0.8 * A
DRIVE
Dropout voltage VDIF
1.0 V IO 0.8A TSD DET
ERR
Line regulation VO LINE 30 mV VIN =8 to 16V
Notes:
*1. Since P D (max) = (VIN VO) IO =22 (W), VIN (max) and IO (max) may be limited depending on operating
conditions. Refer to the Ta P D curve to compute the corresponding values.
*2. Refer to the dropout voltage. Standard Circuit Diagram
*3. IS1 rating shall be the point at which the output voltage VO (VIN=14V, I O=0.5A) drops to 5%.
D1 *2
1 5
SI-3003S
2 4
DC input + *1 N.C 3 N.C + DC output
C2 CO
VIN C1 VO
8
Io vs VDIF Characteristics Line Regulation Load Regulation
0.5 5.1 5.1
0.4
Dropout voltage VDIF (V)
5.0
0 0 0
0 0.2 0.4 0.6 0.8 0 5 10 15 20 25 30 35 0 0.2 0.4 0.6 0.8
Output current IO (A) Input voltage VIN (V) Output current IO (A)
4.9 0 0
50 0 50 100 150 0 2 4 6 8 10 0 5 10 15 20 25 30 35
Ambient temperature Ta (C) Input voltage VIN (V) Input voltage VIN (V)
4 4 (2.3C/W)
Output voltage VO (V)
15
100 100 2mm
3 3 (5.2C/W)
10
2 VIN =6V 2 75 75 2mm
14V (7.6C/W)
1 5
35V 1
Without heatsink
25V
0 0 0
0 0.5 1.0 1.5 2.0 2.5 120 140 160 180 200 40 0 40 80 100
9
This datasheet has been downloaded from: