Isweek SprintIR CO2 Sensor
Isweek SprintIR CO2 Sensor
Isweek SprintIR CO2 Sensor
3.3V supply
SprintIR Sensor
10000
Instantaneous Concentration
8000
6000
(ppm)
4000
2000
0
0 1 2 3 4
Time (s)
Specifications
CO2 Measurement
Sensing Method Non-dispersive infrared (NDIR) absorption
Patented Gold-plated optics
Patented Solid-state source and detector
Sample Method Diffusion(Standard) / Flow through (with flow-through adapter)
Measurement Range 0-5%, 0-20%, 0-60%, 0-100%
Accuracy 70 ppm +/- 5% of reading1
Measurement Noise <10% of reading with no digital filtering
Non Linearity < 1% of FS
Pressure Dependence 0.1% of reading per mbar in normal atmospheric conditions
Operating Pressure Range 950 mbar to 10 bar2
General Performance
Warm-up Time < 1 minute
Operating Conditions 0C to 50C (Standard)
-25C to 55C (Extended range)
0 to 95% RH, non-condensing
Recommended Storage -30C to +70C
Electrical/ Mechanical
Power Input 3.2 to 5V. (3.3V recommended)
Peak current 100mA
Average Current <15mA
Power Consumption 35 mW
Output UART only
Dimensions and Wiring Connections
2x5 0.1 header. Pin 1 is identified on the dimensional drawing.
The zeroing options are for hardware zeroing (both active low). These functions can also be
implemented by sending a serial command (recommended).
Typical connections for digital interface are GND, 3.3V, Rx and Tx. Note that the Vh for the serial
Tx line will be 3V regardless of the supply voltage.
Note 1: All measurements are at STP unless otherwise stated.
Note 2: External Pressure calibration required.
Note 3: User Configurable Filter Response.
This documentation is provided on an as-is basis and no warranty as to its suitability or accuracy for any particular purpose is either made or
implied. Gas Sensing Solutions Ltd will not accept any claim for damages howsoever arising as a result of use or failure of this information. Your
statutory rights are not affected. This information is not intended for use in any medical appliance, device or system in which the failure of the
product might reasonably be expected to result in personal injury. This document provides preliminary information that may be subject to change
without notice.