0% found this document useful (0 votes)
27 views23 pages

Controles Practicas

This document contains information about the design of a building foundation including: 1. The foundation will be 648.90 square meters and support a total load of 4812.485 tons. 2. Settlement calculations determine the foundation will settle 0.6180 centimeters, within acceptable limits. 3. The majority of the foundation area, over 75%, will be a slab or raft foundation.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
27 views23 pages

Controles Practicas

This document contains information about the design of a building foundation including: 1. The foundation will be 648.90 square meters and support a total load of 4812.485 tons. 2. Settlement calculations determine the foundation will settle 0.6180 centimeters, within acceptable limits. 3. The majority of the foundation area, over 75%, will be a slab or raft foundation.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 23

n =5

At = 20.00 m
P servicio = 1250 kg/m
f'c = 210 kg/cm
Acol= 1323 cm

1350
1. Capacidad portante
(+)/

AREA 484
Tipo de
qa = 7.50 t/m cimentacion 134%
Pedif = 4345.280 t
Pcim = 521.434 t
Acim 648.90 m

2. Asentamientos
=/(1) Rango de asentamiento tolerables
S0
C1 = 1200.0 t/m COEFICIENTE DE BALA S1
Acim = 648.90 m S2
Ptotal = 4812.485 t S3
St = 0.6180 cm
AREA CIMENT TIPO DE CIMEN

<50% ZAPATAS AISLADAS 943670.4


VIGAS T INVERTIDA O
50-75% ZAPATA COMBINADA 273800
>75% LOSA O PLATEA DE CIM. 317608
21904
1556982.4

e asentamiento tolerables
St = 0
St 0.5 cm
0.5< St 1 cm
1< St 1.5 cm
ALTURAS H PARA PSE. COLUMNAS MUROS
CANTIDAD 24 4 21.6
DIMENSIONES 0.3 0.9 3 0.2 0.3 0.4
1er PISO 3.5 3.375 52488 19440 6220.8
2Do PISO 3.25 1.625 25272 9360 6220.8
77760 28800 12441.6

ALTURAS COLUMNAS MUROS


CANTIDAD 8 16
DIMENSIONES 0.5 0.5 4 0.3
1er PISO 5 77760 28800
2do PISO 3.5 54432 20160
3er PISO 3.5 54432 20160
4to PISO 3.5 54432 20160
5to PISO 3.5 54432 20160
6to PISO 3.5 54432 20160

VIGAS
Nmero Longitud Dimen. Peso
V1 X-X 16 3.75 0.5 0.3 21600
V2 X-X 4 6 0.5 0.3 8640
V3 X-X 4 5.5 0.5 0.3 7920
total 38160

Aligerados Espesor Losa Superior N Paos LX LY rea


1 Direccin A 20 5 4 3 3 36
1 Direccin B 20 5 6 4 3 72
1 Direccin C 20 5 2 3 5 30
1 Direccin D 20 5 3 4 5 60
198
PESO SISMICO EFECTICO

VIGAS LOSAS CM
16.8 18.8 9.4 37.2
0.3 0.4 0.3 0.5 0.3 0.5 0.3 0.5
4838.4 6768 3384 13392 41580 148111.2
4838.4 6768 3384 13392 41580 110815.2
9676.8 13536 6768 26784 83160 258926.4

PESO TOTAL DE LA ESTRUCTURA

VIGAS LOSAS CM

0.5 0.3
38160 41580 186300
38160 41580 154332
38160 41580 154332
38160 41580 154332
38160 41580 154332
38160 41580 154332
957960

m/m Peso
0.0875 7560
0.0875 15120
0.0875 6300
0.0875 12600
41580
CV entrepiso CV TECHO CM tabiques CM ENTREP CM CV

500 300 59400 207511.2 99000


200 300 59400 170215.2 39600
118800 377726.4 138600
P.S.E.
ZUCS/R
V

CV entrepiso CV TECHO CM tabiques CM CV

500 370 259560 99000


500 370 227592 99000
500 370 227592 99000
500 370 227592 99000
500 370 227592 99000
100 100 174132 19800
PESO TOTAL
PESO SISMICO PESO TOTAL
EFECTICO
257011.2 306511.2 338720
180115.2 209815.2 687680

437.126 Tn 516326.4
0.2652
115.9259 Tn

PESO SISMICO PESO TOTAL


EFECTICO
358560 358560
326592 326592
326592 326592
326592 326592
326592 326592
193932 193932
1858.860 Tn
METODO RAPIDO
SISMO EN X FUERZA SISMO EN Y
COLUMNAS 10.4753 1.27% COLUMNAS
MUROS 814.0939 98.73% MUROS
TOTAL 824.5692 TOTAL
824.56

Load
METODO EXACTO Story Pier Case/Comb Location
o

SE VERIFICA asignando a Story1 PLACA 1 SISMO EX 1 Top


todas las placas su pier y Story1 PLACA 2 SISMO EX 1 Top
luego en tables-analisis- Story1 PLACA 3 SISMO EX 1 Top
results-wall results- piers Story1 PLACA 4 SISMO EX 1 Top
y listo se verifica la
direccion y nada mas

Load
Story Pier Case/Comb Location
o

Story1 PLACA 1 SISMO EY 1 Top


Story1 PLACA 2 SISMO EY 1 Top
Story1 PLACA 3 SISMO EY 1 Top
Story1 PLACA 4 SISMO EY 1 Top

Story Load Case/C Direction Drift

Story5 DERIVA Max Y 0.005475


Story4 DERIVA Max Y 0.00544
Story5 DERIVA Max X 0.005337
Story4 DERIVA Max X 0.005316
Story6 DERIVA Max Y 0.005274
Story6 DERIVA Max X 0.005132
Story3 DERIVA Max Y 0.004964
Story3 DERIVA Max X 0.004862
Story2 DERIVA Max Y 0.003864
Story2 DERIVA Max X 0.003795
Story1 DERIVA Max Y 0.001806
Story1 DERIVA Max X 0.001781
FUERZA
6.9893 4.28%
156.2016 95.72%
163.1909

P V2 V3 T M2 M3

tonf tonf tonf tonf-m tonf-m tonf-m


9.0129 0.1737 -3.264 -0.0395 4.3516 -0.4597
9.0129 0.1737 -3.264 0.0395 4.3516 0.4597
-9.0129 0.1737 -3.264 0.0395 4.3516 -0.4597
-9.0129 0.1737 -3.264 -0.0395 4.3516 0.4597

placas en x 0.6948 1%
V total 111.5902 100%

P V2 V3 T M2 M3

tonf tonf tonf tonf-m tonf-m tonf-m


0.9228 25.9151 -0.0012 -0.018 0.0029 -12.1223
-0.9228 25.9151 0.0012 -0.018 -0.0029 -12.1223
-0.9228 25.9151 -0.0012 0.018 0.0029 -12.1223
0.9228 25.9151 0.0012 0.018 -0.0029 -12.1223

placas en Y 103.6604 93%


V total 111.5902 100%

Label X Y Z
m m m
5 0 14.8 16.5
5 0 14.8 13.25
25 14.8 14.8 16.5
25 14.8 14.8 13.25
5 0 14.8 19.75
25 14.8 14.8 19.75
5 0 14.8 10
25 14.8 14.8 10
5 0 14.8 6.75
25 14.8 14.8 6.75
5 0 14.8 3.5
25 14.8 14.8 3.5
DISTRIBUCIN DE FUERZA CORTANTE BASAL EN ANALISIS ESTTICO CON PERIODO FUNDAMENTAL T0.7 s

ZUCS/R= 0.2011
V= 87.9061 t Fuerza Cortante basal
T = 0.2944
k = 1.0000 k = 0.75+0.5T; para T 0.5 s
Fuerzas
entrepiso

Nivel hi (m) P (tf) Pxhik (Pxhik)/(Pxhik) fi (tf)


2 6.75 180.115 1215.778 57.47% 50.524
1 3.5 257.011 899.539 42.53% 37.382
SUMA= 437.126 2115.317 100.00% 87.906
Donde:
fi: Fuerza cortante
Fi: Fuerza cortante de nivel

Momento actuante
7.3 Momento de Volteo Ma 472
Toda estructura y su cimentacin debern ser
diseadaspara resistir el momento de volteo que produce Momento resistente
un sismo,segn los numerales 4.5 o 4.6. El factor de brazo 6
seguridad calculado con las fuerzas que se obtienen en Mr 2623
aplicacin deesta Norma deber ser mayor o igual que
1,2.
Factor de Seguridad al Volteo
FS 5.6 OK
FUNDAMENTAL T0.7 s

F cortante de
nivel
Fi (tf) o Vpor
piso di PiXdi2 fixdi Masa de Etabs (kg)
50.5240 0.0033 0.0019 0.1646 180115.2
87.9061 0.0018 0.0009 0.0689 257011.2
0.0028 0.2335

T= 0.219095453 modo 1
T'= 0.219095453 modo 2
Nivel Peso (t)
2 180.115
1 257.011
P = 437.126 t
DISTRIBUCIN DE FUERZA CORTANTE BASAL EN ANALISIS ESTTICO CON PERIODO FUNDAMENTAL T0.7 s

ZUCS/R= 0.2681
V= 117.1936 t Fuerza Cortante basal
T = 0.3690
k = 1.0000 k = 0.75+0.5T; para T 0.5 s
Fuerzas
entrepiso

Nivel hi (m) P (tf) Pxhik (Pxhik)/(Pxhik) fi (tf)


2 6.75 180.115 1215.778 57.47% 67.357
1 3.5 257.011 899.539 42.53% 49.837
SUMA= 437.126 2115.317 100.00% 117.194
Donde:
fi: Fuerza cortante
Fi: Fuerza cortante de nivel

Momento actuante
7.3 Momento de Volteo Ma 629
Toda estructura y su cimentacin debern ser
diseadaspara resistir el momento de volteo que produce Momento resistente
un sismo,segn los numerales 4.5 o 4.6. El factor de brazo 6
seguridad calculado con las fuerzas que se obtienen en Mr 2623
aplicacin deesta Norma deber ser mayor o igual que
1,2.
Factor de Seguridad al Volteo
FS 4.2 OK
FUNDAMENTAL T0.7 s

F cortante de
nivel
Fi (tf) o Vpor
piso di PiXdi2 fixdi Masa de Etabs (kg)
67.3570 0.0008 0.0001 0.0506 180115.2
117.1936 0.0003 0.0000 0.0165 257011.2
0.0001 0.0671

T= 0.088264564 modo 1
T'= 0.088264564 modo 2
Nivel Peso (t)
2 180.115
1 257.011
P = 437.126 t
Story Load Case/C Direction Drift
6 Story6 DERIVA Max X 0.003734 0.3734
5 Story5 DERIVA Max X 0.003909 0.3909
4 Story4 DERIVA Max X 0.003942 0.3942
3 Story3 DERIVA Max X 0.003705 0.3705
2 Story2 DERIVA Max X 0.003087 0.3087
1 Story1 DERIVA Max X 0.001526 0.1526
0 0

LIMITES DE DERIVAS

2; 6 1; 6

3; 5 2; 5

4; 4 3; 4

5; 3 4; 3

6; 2 5; 2

7; 1 6; 1

8; 0 7; 0

DERIVAS
LIMITE DER.
Story Load Case/C Direction Drift
0.7 Story2 DERIVA Max X 0.004635
0.7 Story1 DERIVA Max X 0.005811
0.7
0.7 Story Load Case/C Direction Drift
0.7 Story2 DERIVA Max Y 0.001043
0.7 Story1 DERIVA Max Y 0.000693
0.7
EL T TENEMOS Q UBICARLO PARA SABER EL VAOR DE K EN EL ESPECTRO
EL T NO TIENE Q SER NADA PARECIDO A LOS VALORES DE TP Y TS , ESTO PARA EVITAR TENER EL MISM
SI EN CASO ES IGUAL ESTA SE CAMBIA MODIFICANDO LA ESTRUCTURACION OSEA HACIE
- SE VERIFICA EL T Y QUE LA SUMA DE LAS MASAS DE ESTE PASE EL 90%
TO PARA EVITAR TENER EL MISMO PERIODO Q EL SUELO Y ASI EVITAR RESONANCIA
ESTRUCTURACION OSEA HACIEDNO MAS RIGIDA LA ESTRUCTURA MAS PERALTE EN TOO
TE PASE EL 90%
Tabla N . Escalamiento para diseo

Peso SISMICO EFECTIVO de la edific. 437.1264 tf


Coeficiente de cortante basal X (zucs/R) 0.2011
Coeficiente de cortante basal Y (zucs/R) 0.2681
Cortante basal de sismo esttico X 87.9061 tf
Cortante basal de sismo esttico Y 117.1936 tf
80% Cortante de sismo esttico X 70.3249 tf
80% Cortante de sismo esttico Y 93.7549 tf
Cortante basal de sismo dinmico XX 653.0357 tf
Cortante basal de sismo dinmico YY 609.2031 tf
Factor a escalar XX 0.10768920479
Factor a escalar YY 0.15389755941
0.9 PARA IRREGULAR
0.8 PARA REGULAR