Energy Savings by Waste Water Heat Recovery System

This document discusses how waste water heat recovery systems and heat recovery water heating can save a significant amount of energy and money. Up to 90% of the energy used for water heating is wasted when warm water goes down the drain. A waste water heat recovery system can capture this wasted energy and generate annual cost savings of Rs. 8,393 to Rs. 27,452 depending on the system and configuration. Heat recovery water heating uses the wasted heat rejected from air conditioner condensers, which can heat water and reduce water heating costs substantially, especially for commercial locations that require lots of hot water. Savings come from both utilizing free waste heat and improving air conditioner efficiency.

Uploaded by

Hamza Nawaz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
96 views2 pages

Energy Savings by Waste Water Heat Recovery System

This document discusses how waste water heat recovery systems and heat recovery water heating can save a significant amount of energy and money. Up to 90% of the energy used for water heating is wasted when warm water goes down the drain. A waste water heat recovery system can capture this wasted energy and generate annual cost savings of Rs. 8,393 to Rs. 27,452 depending on the system and configuration. Heat recovery water heating uses the wasted heat rejected from air conditioner condensers, which can heat water and reduce water heating costs substantially, especially for commercial locations that require lots of hot water. Savings come from both utilizing free waste heat and improving air conditioner efficiency.

Uploaded by

Hamza Nawaz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

Energy Savings by Waste water Heat

recovery system
The cost of heating water is the largest energy expense but most of this
water ends up going down the drain. Warm drain water is a source of
potential energy savings often ignored. In fact, approximately 90% of the
energy used for water heating is wasted down the drain. In North America
alone this loss represents about $40 billion each year.

A Power-Pipe Drain Water Heat Recovery (DWHR) System can recover a


large portion of that energy and generate significant cost savings in a broad
range of commercial applications, while reducing greenhouse gas emissions.

What can we save with DWHR :

Natural gas water heater + DWHR

Annual cost savings: 8393.75 Rs to 13726.25 Rs

Oil water heater + DWHR

Annual cost savings: 13133.75 Rs to 21428.75 Rs

Electric water heater + DWHR

Annual cost savings: 16886.25 Rs to 27452.50 Rs

Savings depend on DWHR model and configuration.

Heat Recovery Water Heating

Heat recovery water heating is the heating of heating domestic hot water
with the waste heat from the air conditioning system. This heat is rejected
from the air conditioner's condenser to the atmosphere. By recovering this
wasted heat and utilizing it to heat water, it is possible to substantially
reduce water-heating costs.

Recovery:

An air conditioning system with a water-cooled condenser, while producing a


ton of refrigeration or 12,000 BTU per hour of cooling capacity rejects
approximately 15,000 BTU per hour of heat to the atmosphere. An air
conditioning system with an air-cooled condenser rejects about 16,000-
17,000 BTU per hour of heat for each ton of capacity. 3,000-5,000 BTU per
hour per ton is relatively easy to recover with a very nominal investment in
equipment. This is virtually free heat.

A residence with a three-ton air conditioner could expect from 15-to-25


gallons of hot water raised from 70 to-140 F every hour the air conditioner is
running. With a five ton air conditioner a, possible 25-to-40 gallons could be
recovered. This hot water would be available during the summer months
when the air conditioner is running fairly consistently. As the outdoor
temperatures decrease the air conditioner will run less thereby making less
hot wafer available. With heat pump, hot water from the heat recovery
system is available during the winter as well as the summer months.

Even greater savings can be realized in some type of commercial


establishments where the hot water requirements are heavy and there is a
high internal heat gain from lights and people in the public area causing the
air conditioner to run even during the winter months. Some restaurants,
motels and Laundromats have been able to obtain 100% of their hot water
during the cooling season from the heat recovery system.

It can be seen that during periods when the air conditioning system is
operating, the waste heat can produce sizeable amounts of hot water.
Additional savings are realized from reduced costs of operating the air
conditioning system because of the improved condensing action of the heat
exchanger.