Particle Size Distribution by Hydrometer Analysis

This document summarizes the results of a hydrometer analysis test conducted on a soil sample from a boring in Jakarta, Indonesia. The test measured the particle size distribution of the soil over time as larger particles settled out of suspension. Most of the soil particles (98.2%) were smaller than 0.425 mm, with 93.2% passing a #200 sieve (0.075 mm). The hydrometer readings showed that after 1440 minutes, 17.42% of particles had diameters smaller than 0.0011 mm.

Uploaded by

sunartililik
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views1 page

Particle Size Distribution by Hydrometer Analysis

This document summarizes the results of a hydrometer analysis test conducted on a soil sample from a boring in Jakarta, Indonesia. The test measured the particle size distribution of the soil over time as larger particles settled out of suspension. Most of the soil particles (98.2%) were smaller than 0.425 mm, with 93.2% passing a #200 sieve (0.075 mm). The hydrometer readings showed that after 1440 minutes, 17.42% of particles had diameters smaller than 0.0011 mm.

Uploaded by

sunartililik
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

PARTICLE SIZE DISTRIBUTION BY HYDROMETER ANALYSIS

Lab Ref. : Gs Soil 2.64


Date Tested : a 1.002
Project : TANJUNG PRIOK ACCES ROAD SECTION - E Ws (gr) 50.00
Location : JL. CACING, JAKARTA W (gr) 50.92
Boring : BH-A-1 (L) % Passing # 10 98.20
Depth 12.00-12.50 M
Soil Description : % Passing # 200 93.20
======== ========== ========== ========== ========= ========== ============= ============== ============
Hydrometer Equiv. Particle % of Particle
Time TemperatureElapsed Time REading Zr Factor Diameter r-rw Finer Diameter
(R'h) (F) (D) in mm (N)
======== ========== ========== ========== ========= ========== ============= ============== ============
28.00 0.50 49.00 9.60 0.01250 0.0548 49.50 90.79
28.00 1 45.00 10.30 0.01250 0.0401 45.50 83.45
28.00 2 41.00 10.90 0.01250 0.0292 41.50 76.12
28.00 5 36.00 7.30 0.01250 0.0151 36.50 66.94
28.00 15 31.00 8.10 0.01250 0.0092 31.50 57.77
28.00 30 27.00 8.75 0.01250 0.0068 27.50 50.44
28.00 60 24.00 9.20 0.01250 0.0049 24.50 44.94
28.00 120 21.00 9.70 0.01250 0.0036 21.50 39.43
28.00 180 18.00 10.20 0.01250 0.0030 18.50 33.93
29.00 240 15.00 10.65 0.01235 0.0026 15.50 28.43
29.00 300 13.00 11.00 0.01235 0.0024 13.50 24.76
29.00 360 12.00 11.15 0.01235 0.0022 12.50 22.93
28.00 1440 9.00 11.65 0.01250 0.0011 9.50 17.42
======== ========== ========== ========== ========= ========== ============= ============== ============

19.000
9.500
4.750 100.0
2.000 98.2
1.180 97.2
0.425 95.8
0.250 94.8
0.106 93.6
0.075 93.2
0.0548 90.79
0.0401 83.45
0.0292 76.12
0.0151 66.94
0.0092 57.77
0.0068 50.44
0.0049 44.94
0.0036 39.43
0.0030 33.93
0.0026 28.43
0.0024 24.76
0.0022 22.93
0.0011 17.42