0% found this document useful (0 votes)
5K views

Manual Rfid Access Control

This document provides instructions for an RFID access control system. It allows access via RFID card, card and password, or password. The system stores information for 500 users and has functions like door monitoring, alarms, and anti-tampering. It can be set up for different access modes and parameters like open duration. Installation involves wiring the system and programming user access and settings using the control panel.

Uploaded by

dovito72
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
5K views

Manual Rfid Access Control

This document provides instructions for an RFID access control system. It allows access via RFID card, card and password, or password. The system stores information for 500 users and has functions like door monitoring, alarms, and anti-tampering. It can be set up for different access modes and parameters like open duration. Installation involves wiring the system and programming user access and settings using the control panel.

Uploaded by

dovito72
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 11

RFID

Access Control System

Users Manual

Please read this manual thoroughly before installation.


1. Brief Product Introduction:

This product is RFID access control system, which is currently one of the advanced

access systems. It uses the latest central process unit (CPU) and memory chip of large capacity.

There will be of no information loss even in case of power failure. It takes the latest

HOMMARD technology, with strong power of three ways to open door: open by card read,

open by card read adding with password, and open by password.

The perfect security functions let the users feel much more safe, which include door state

monitoring, alarm output, safety mode, anti dismantling, RFID card and password. While its

functions of opening button, close notification, door bell, to be connected with NO. and NC.

locks bring more operating easiness to the users.

This product provides access control mode, which is safe and fully automatic, it is an

ideal device for business organizations, offices, factories, residences and communities.

2. Technical Features

No. Item Specification

1 Power supply DC: Voltage 12V10%; current < 0.1A


2 Max load Alarm output: 100mA Electrolock output:

5A

3 Dimension 116mm116mm20mm

4 Weight 180g

5 Ambient temp. -2060

6 RH 20%90%

7 Memory capacity Information of 500 user card, and 500

passwords

8 Induction distance 515CM

9 Car type EM or EM compatible card

Status Indications:

LED Indicators

Status Red LED Green LED

Normal state Flash

Valid card Light

Invalid card Light


Open Light

Key Press Light

Program Mode Light Flash frequent

Set OK Light Light

Alarm Flash

Buzzer

Status Description Buzz

Valid card Two short beeps BiBi

Invalid card Long beep once Bi

Key Press Short beep once Bi

Input valid Two short beeps BiBi

password

Input wrong Long beep once Bi

password

Alarm state Continuous long beeps BiBiBi


4. Setup:
1. Default value: Login password 9 9 9 9 ,User password 1 2 3 4

2. Enter programming mode:

Press * Login password # enter programming mode.

3. Function setup (should be in programming mode):

1). Modify login password.

Press 0 new password # confirm new password #

Note: the new password should be any 4-8 figures.

2). Add user card.

Press 1 read card Input code #

Note: the code should be three figures from 001 to 500, which

should not duplicate. The code must be input, otherwise the card will

be invalid. If add more than one cards, read the second card directly

after the first three-digit code is put in before pressing # .

3). Delete user card (three ways):

A. Press 2 0 0 0 0 # to delete all user cards.

B. Press 2 read card # to delete the corresponding card


C. Press 2 input code # to delete lost card.

4) Set open mode:

Press 3 0 0 # by valid card only.

Press 3 0 1 # by valid card and password.

Press 3 0 2 # by valid card or password.

Note: factory setting is valid card.

Since the initial password can not be used to open door, If set to

valid card or password mode, password for use should be

modified.

5). Set the length of open time:

Press 4 X X # .

Note: XX is from 00-99, unit is second, factory setting is 6

seconds.

6). Set the length of alarm time:

Press 5 X X # .

Note: XX is from 00-99, unit is minute, factory setting is 3

minutes.

7) Set door state monitoring mode:


Press 6 0 0 # to disable this function.

Press 6 0 1 # to enable this function.

Note: to enable door state monitoring, reed switches must be

installed, when this function is enabled, the following two

functions can also be enabled at the same time:

A. If the user put in the correct password to open the door,

then forget to close the door, the buzzer will give

audible sound to note the user.

B. If the door is opened illegally, the system will activate

alarm signal output, at the same time, buzzer emits sound

alarm.

8). Set safety mode:

Press 7 0 0 # to disable this function.

Press 7 0 1 # to read 10 invalid cards or valid cards,

then enter 4 wrong passwords successively, the system is locked for

10 minutes.

Press 7 0 2 # to read 10 invalid cards or valid cards,

then enter 4 wrong passwords successively, the system activates


alarm signal output.

Note: factory setting this function is disabled.

9) Save the settings and exit programming mode:

Press * .

Note: * should be pressed within 1 minute to save the setting when

any of the above operation is completed.

4. Modify user password (no need in programming mode): after pressing * to read

user card, the green LED flashes, input user password then press

# to enter password modifying mode. Now input new password of 4

figures, press # and input the new password again, press # to

save the setting.

5. How to use:

1). In normal work mode, can be open by one valid card.

2). When valid card and password mode, can be open if the correct

password is put in within 10 seconds after card swiping.

3). If the password of a card is forgotten, the information of this

card in the system should be deleted first, then add this card to the
system again to modify the password.

4). If program password is forgotten, you can use jumper

switchRESETat the main board to restore factory setting. First,

power off. Then set jumper switch toONposition. Power on. Shift

the jumper switch back to OFFposition after three beeps of the

buzzer, now the factory setting is restored.


Attachment: wiring diagram for installation

NOTE: 1. Power off before installation wiring, hot line work is forbidden!!
2. Normally, electrolock is connected out from power controller.