LT/HT Power &

Control Cables

Catalogue 2016
HT Power Cables upto 66kV
1.1 kV Power Cables
1.1 kV Copper Control Cables
Certication

Building customer condence by providing a wide range of quality


products and services through team work.
Havells India Ltd is a billion-dollar-plus organization, and is one of the largest & Indias fastest growing electrical and power distribution equipment
manufacturer with products ranging from Industrial & Domestic Circuit Protection Switchgear, Cables & Wires, Motors, Fans, Power Capacitors, CFL Lamps,
Luminaires for Domestic, Commercial & Industrial applications, Modular Switches, Water Heaters and Domestic Appliances covering the entire gamut of
household, commercial and industrial electrical needs.

Havells owns some of the prestigious global brands like Crabtree, Sylvania, Concord, Luminance & Standard. With 94 branches / representative offices and
over 8000 professionals in over 50 countries across the globe, the group has achieved rapid success in the past few years. Its 15 state-of-the-art
manufacturing units in India located at Haridwar, Baddi, Noida, Faridabad, Alwar, Neemrana, and 9 state-ofthe- art manufacturing plants located across
Europe, Latin America & Africa churn out globally acclaimed products. Havells is a name synonymous with excellence and expertise in the electrical industry.
Its 20000 strong global distribution network is prompt to service customers.

The company has acquired a number of International certifications, like CSA, KEMA, CB, CE, ASTA, CPA, SEMKO, SIRIUM (Malaysia), SPRING (Singapore),
TSE (Turkey), SNI (Indonesia) and EDD (Bahrain) for various products. Today, Havells and its brands have emerged as the preferred choice of electrical
products for discerning individuals and industrial consumers both in India and abroad.

In an attempt to transform itself from an industrial product company to a consumer products company, Havells launched the consumer electrical products
such as CFLs, Fans, Modular Switches Luminaires, Water Heaters and Domestic Appliances. The company has been consistent in its brand promotion with
sponsorship of Cricket events like T20 World Cup, India- Australia Series and IPL Season first, second, third, fourth & fifth.

The company has also taken the initiative to reach directly to the consumers through Havells Galaxy a one stop shop for all electrical and lighting needs.
Havells has more than 100 such Galaxies across the country.
Index
Introduction
Manufacturing Process 5
Manufacturing of Cables 6
Advantages 7
Cable ranges at a glance 8-9

LT Power & Control Cable


1.1 kV Single Core, PVC Insulated, Un-armoured Cables 12
1.1 kV Two Core, PVC Insulated, Un-armoured Cables 13
1.1 kV Three Core, PVC Insulated, Un-armoured Cables 14
1.1 kV Three & Half Core, PVC Insulated, Un-armoured Cables 15
1.1 kV Four Core, PVC Insulated, Un-armoured Cables 16

1.1 kV Single Core, PVC Insulated, Armoured Cables 17


1.1 kV Two Core, PVC Insulated, Armoured Cables 18
1.1 kV Three Core, PVC Insulated, Armoured Cables 19
1.1 kV Three & Half Core, PVC Insulated, Armoured Cables 20
1.1 kV Four Core, PVC Insulated, Armoured Cables 21

1.1 kV 1.5 sq. mm Copper Cond. PVC Insulated, Un-armoured / Armoured Cables 22
1.1 kV 2.5 sq. mm Copper Cond. PVC Insulated, Un-armoured / Armoured Cables 23

1.1 kV Single Core, XLPE Insulated, Un-armoured Cables 24


1.1 kV Two Core, XLPE Insulated, Un-armoured Cables 25
1.1 kV Three Core, XLPE Insulated, Un-armoured Cables 26
1.1 kV Three & Half Core, XLPE Insulated, Un-armoured Cables 27
1.1 kV Four Core, XLPE Insulated, Un-armoured Cables 28

1.1 kV Single Core, XLPE Insulated, Armoured Cables 29


1.1 kV Two Core, XLPE Insulated, Armoured Cables 30
1.1 kV Three Core, XLPE Insulated,Armoured Cables 31
1.1 kV Three & Half Core, XLPE Insulated,Armoured Cables 32
1.1 kV Four Core, XLPE Insulated, Armoured Cables 33

1.1 kV 1.5 sq mm Copper Cond. XLPE Insulated, Un-armoured / Armoured Cables 34


1.1 kV 2.5 sq mm Copper Cond. XLPE Insulated, Un-armoured / Armoured Cables 35

HT Power Cable
3.3 kV Single Core, XLPE Insulated, Armoured Cables - Non Screened 38
3.3 kV Three Core, XLPE Insulated, Armoured Cables - Non Screened 39

3.3 kV Single Core, XLPE Insulated, Armoured Cables - Screened 40


3.3 kV Three Core, XLPE Insulated, Armoured Cables - Screened 41

3.8/6.6 kV Single Core, XLPE Insulated, Armoured Cables 42


3.8/6.6 kV Three Core, XLPE Insulated, Armoured Cables 43

6.6/6.6 kV& 6.35/11Kv Single Core, XLPE Insulated, Armoured Cables 44


6.6/6.6 kV& 6.35/11Kv Three Core, XLPE Insulated, Armoured Cables 45

11/11kV Single Core, XLPE Insulated, Armoured Cables 46


11/11kV Three Core, XLPE Insulated, Armoured Cables 47

12.7/22 kV Single Core, XLPE Insulated, Armoured Cables 48


12.7/22 kV Three Core, XLPE Insulated, Armoured Cables 49

19/33 kV Single Core, XLPE Insulated, Armoured Cables 50


19/33 kV Three Core, XLPE Insulated, Armoured Cables 51

Basic assumption for current ratings & rating factors 52-53


Selection criteria of M/VHV cable size for primary distribution 54
Standard Drum lengths of Cables 55
Quality Control & Test 56
Selection Guide 57
Handling & Storage 58
List of Major Customer 59
Fire Survival Cables 61
Solar Cables 62

Details for BIS Licences


For PVC Cables For XLPE Cables For 66kV Cables
IS:1554 (Part-1), 1988 IS:7098 (Part-1), 1988 IS:7098 (Part- 3)
CM/L No.: 81579 82 CM/L No.: 81896 92 CM/L No : 3098967
IS:1554 (Part-2), 1988 IS:7098 (Part-2), 1985
CM/L No.: 82594 85 CM/L No.: 83683 89
Manufacturing Process
Manufacturing of Cables
Cables with Aluminium and Copper conductor and polymer insulation are Insulation Insulation screening shall consist of non-metalic
manufactured at Havells India Ltd. (Cable Works) Alwar. Essentially cables
Screen Part in combination with metalic part. Non metalic
comprise of conductors, insulation, inner-sheath, armour and outersheath.
part shall consist of either semi conducting
The brief description of the process is mentioned as under:
compound tape applied hellically or extruded layer
of semi conducting compound, applied directly
CONDUCTOR
over insulation. Over this, metalic part (copper tape)
Havells Cables are available with both aluminum and copper conductors. It shall be applied hellically with overlap as per IS:7098 part 2.
is manufactured with solid/Stranded Circular/ Shaped Aluminium / Copper
To avoid the cavities and voids formation in dielectric particularly on bending
Conductor. Stranding makes Cables exible and easy to handle while shaping
operation of cable, perfect bonding of insulation and screening is required.
makes them compact.
To ensure this Havells applying conductor screen, insulation and insulation
Compaction is provided to all stranded conductor constructions as under: screen (non-metalic part) in one operation through tripple extrusion.
1. Circular Conductor With one wire in the centre conductor contains 6, 12, LAYING UP
18, 24, 30... wire layers in either unilay or opposite helical directions. The
Cores are tested on line during production both for physical and electrical
conductor is sized upto 92% compaction.
characteristics. Control is observed within tight tolerance limits for dimensions
2. Shaped Conductors In all multicore cables from 16 Sq. mm size, in case pf PVC/XLPE insulation. For multicore cables cores are laid up on
conductors are shaped. Compaction degree in multicore power cables our latest laying up machine equipped with sector correction equipment. In
is upto 92%. case of XLPE insulated cores the same are cured so as to impart the requisite
3. Segmental Conductor As a special case Havells cables of 1600 sq. mm characteristics both electrical and mechanical and then are laid up.
are made up of segmental conductors. INNERSHEATH
The conductor is manufactured in equal segments and compacted, then laid Laid up cables are provided with inner sheath with high quality of PVC which
together. This reduces A.C. losses in the large sized conductor, which are acts as bedding for steel wire / strip armouring. Wherever required, ller cords
due to skin and proximity effects. are provided to maintain the circularity to laid up cables.
Havells has special construction of conductor to suggest to its customer for In Havells Cable-polymers used for inner sheath are softer than insulation or
meeting their specic need. outer sheath & are compatible with temperature ratings of cables & do not
Havells copper conductor cables are of the same construction that of have deleteriocus effect on any other component of cable.
cables with Aluminium conductor except for high tensile strength, superior Inner sheath is applied either with extrusion or by wrapping. In Havells Cables
conductivity, better exibility and ease of jointing, copper cables are used in though the inner sheath is closely applied on the laid up cores, same can be
control, instrumentation, winding, submarine, mining and ship wiring etc. etc stripped with ease without damaging insulation.
applications.
The inner sheath dimensions are maintained strictly in accordance with laid
All conductors for Havells cables are manufactured strictly in accordance with down specication .
National and International specications.
Specication For PVC Cables IS:1554 (Part-I & II)
National specications IS:8130
For XLPE Cables IS:7098 (Part-I & II)
International specication IEC:60228 / BS:6360
DIELECTRIC INSULATION
ARMOURING
Insulation for Havells cables is strictly as per National and International
Mechanical protection to the cable is provided with armouring. Havells single
specications.
core cables are armoured with Aluminium or Aluminium alloy wire/strips, thus
Havells cables are designed and manufactured with polymer dielectrics to avoiding magnetic hysteresis losses on A. C. System.
bear thermal and thermomechanical stresses safely at continuous normal
Multicore cables are provided with galvanised steel wire/strips.
and short circuit temperature conditions.
Havells cables are provided with galvanised wire armouring, where cables are
Havells cables are available with both thermoplastic & thermo setting
to run vertically and are subjected to stresses.
insulations.
Havells Mining cables are armoured with steel wire and tinned copper wires,
- PVC Cables Thermoplastic dielectric
so as to provide conductivity of armour more than 75% of main conductor
- XLPE Cables Thermo setting dielectric of cable.
Havells PVC cables use PVC compounds that take care of over load and Havells cables armour wires/strips are of low resistivity material and meet the
short circuit current with both coarse & ne protection systems. requirements of IS:3975.
Havells XLPE cables use XLPE compound with anti oxidant stabilizers and Havells armoured cables are with almost 95% armour coverage.
traces of aromatic polynuclear hydrocarbon. Thus improving electrical treeing
OUTER SHEATH
characteristics and mechanical strength of insulation.
All Havells Cables are provided with PVC/polymer outer sheath.
Havells cables are friendly during continuous, emergency and short circuit
conditions. Havells Cables are manufactured with various characteristics of sheathing
compounds.
Though there is no change in basic design of Havells cables yet the latest
manufacturing process gives improved reliability and compactness to cables. General purpose sheathing Compound ST1
The relative thermal expansion during short circuit between dielectric and Heat resistant Compound for sheath (H.R.) ST2
conductor is therefore limited to minimum both in PVC & XLPE, thus limiting Fire Retardant Low IEC 754 Part I
displacement of cores in cables during short circuit.
Smoke Compound IEC 60332 Part I& III
Insulation for Havells Cables are strictly manufactured and applied over
(FRLS) IEEE-383
conductor in accordance with National and International specications:
ASTM-2843
National Specication IS:5831/IS:7098
ASTM-2863
International Specications BS:6746/BS:5467/IEC:60502
Flame Retartant Compound (FR) to EIL Specn.
SCREENING
Ultra Voilet Radiations Resistance Compound to ASTM G-53.
XLPE Cables with rated voltage over 3300V shall be provided with conductor
and insulation screening as follows: Anti Rodent and Anti Termite Compound.
Conductor Conductor shall be screened with extruded PVC compounds used for Havells Cables are of various grades to meet
specications IS: 5831.
Screen Semiconducting compound as per is:7098 part 2.
Advantage
In order to be identied, Havells Cables have their name embossed/printed/ ADVANTAGES OF XLPE CABLES
indented on outersheath at regular intervals on the outer sheath of Havells
1. Higher Current Rating.
Cables, Voltage Grade, cable size, trade name & year of manufacture are
embossed, as desired. 2. Higher Short Circuit Rating.
Cables are sequentially marked for length at every metre throughout its 3. Longer Service Life.
length. 4. For a short time it can withstand maximum 130oC and is favourable to
endure short circuit stresses.
FINAL TESTING
5. It is less sensitive to the setting of the network protection.
Each Havells Cable is tested for all applicable Routine Tests.
6. Because of the thermosetting process taking place due the effect of
From a lot of Cable one cable of each type is tested for Type tests, as per cross linking, the crack resistance is increased.
relevant specications.
7. Due to the chemical cross-linking internal stresses are reduced.
Havells conduct its testing at Havells India Ltd. cable plant at Alwar for Consequently the material is less sensitive during manufacturing process
acceptance test as per specication. to the setting of the cooling gradient.
Testing of Havells Cables are carried out as per Havells Work Standards for 8. The thermal resistivity of cross-linked material is favourably low, compared
testing, besides applicable standards. to thermoplastic material.
ADVANTAGES OF PVC CABLES 9. The low dielectric loss is a signicant advantage.
1. A non-hygroscopic insulation almost unaffected by moisture. 10. The excellent mechanical features of the insulation improves the
2. Non-migration of compound permitting vertical installation. protection against external effects.
3. Complete protection against most forms of electrolytic and chemical 11. The resistance of the XLPE to acids, alkalies is outstanding and is often
corrosion. compensating the adverse environmental inuences.
4. A tough and resilient sheath with excellent re - resisting qualities.
5. Good ageing characterstics.

NABL Testing Laboratory


Havells India Ltd has emphasised on product quality by demonstrating quality evaluation for wires & cables at international level by obtaining NABL National
accreditation board for calibration & testing laborites) for testing & DSIR recognised technology center at cable division. NABL is an autonomous body which
is working under the Department of Science & Research Industry (Govt. of India).
National accreditation board for testing and calibration to boast of, it is the rst-of-its-kind private facility in india.The lab fully equipped as per international
standard to test XLPE cables upto 66 kV grade, PVC cables, Flexible cables, aerial bunched cables, photovoltaic cables, instrumentation cables, re survival
cables.
The lab cover indian standards, British standard, International electrotechnical commission (IEC) standards, TUV-Germany standards, American society
for testing and material (ASTM) standards and institute of electrical & electronics engineers (IEEE) standards along with eight type of different re test to
demonstrate re-retardant behavior in cable.
Cable range at a glance
Application Type & Size Options Cross Sectional View
Cables for Power PVC/XLPE Power cables for 1.1 Conductor - Stranded / Solid, Circular /
Supply to & 3.3 kv for Electrical Substations Shaped Aluminium / Copper Outer - Sheath

Residential, as per IS:1554-I & 2/ IS 7098-1 & 2 Insulation - PVC / HR PVC Armouring

Commercial & Sizes: Inner Sheath - PVC / HR PVC / FRLS / PVC Inner - Sheath

Insulation
Industrial units Single Core 10-1000 sq. mm Unarmoured / Armoured - G.S. Round Wire/ Aluminium/

Multicore 6-630 sq. mm Flat Strip or Aluminum Wire / Flat Strip Copper Conductor

Outer Sheath - PVC/ HR PVC/ FRLS PVC


Cables for Power PVC/XLPE Power cables for 1.1 Conductor - Stranded / Solid, Circular /
Supply to & 3.3 kv for Electrical Substations Shaped Aluminium / Copper Outer - Sheath

Armouring
Residential, as per IS:1554-I & 2/ IS 7098-1 & 2 Insulation - PVC / HR PVC
Inner - Sheath
Commercial & Sizes: Inner Sheath - PVC / HR PVC / FRLS / PVC
Insulation
Industrial units Single Core 10-1000 sq. mm Unarmoured / Armoured - G.S. Round Wire/ Aluminium/
Copper Conductor
Multicore 6-630 sq. mm Flat Strip or Aluminum Wire / Flat Strip
Outer Sheath - LSZH Compound
Heavy Duty XLPE XLPE Power cables Conductor - Circular/Shaped - Aluminum/Copper PVC Outer-Sheath

Power cables for upto 19/33 kv grade 33 kv (E) Insulation - XLPE Armouring
PVC Inner-Sheath

Power Generation as per IS:7098 - II Innersheath - PVC / HR PVC / FRLS Filler

Stranded Conductor
Distribution Sizes : Unarmoured / Armoured - G.S Round Wire / Conductor Screening
XLPE Insulation
Single Core : 25 - 1000 sq. mm Flat Strip or Aluminum Wire / Flat Strip Insulation Screening
Metallic Screening
Multicore : 25 - 400 sq. mm Outersheath - PVC / HR PVC / FRLS
Heavy Duty XLPE XLPE Power cables Conductor - Circular/Shaped - Aluminum/Copper PVC Outer-Sheath

Power cables for upto 19/33 kv grade 33 kv (E) Insulation - XLPE Armouring
PVC Inner-Sheath

Power Generation as per IS:7098 - II Innersheath - PVC / HR PVC / FRLS Filler

Stranded Conductor
Distribution Sizes : Unarmoured / Armoured - G.S Round Wire / Conductor Screening
XLPE Insulation
Single Core : 25 - 1000 sq. mm Flat Strip or Aluminum Wire / Flat Strip Insulation Screening
Metallic Screening
Multicore : 25 - 400 sq. mm Outer Sheath - LSZH Compound
Arial Bunched / PE/XLPE insulated 1.1 kv to 33 kv Conductor - Stranded Circular compacted
Bundled required as per IS:14255 & IS:7098-I & II Aluminium Outer Sheath

for over head Insulation - PE/XLPE Cu Tape Screening


Insulation Screening
power distribution Messenger conductor - All Aluminium Alloy-Bare/ XLPE Insulation
Conductor Screening
Insulated Conductor

Street Light Cond. - Stranded Circular AAA


Messenger
Compacted Aluminium, Bare/Insulated Conductor

Fire Survival Annealed electrolytic copper Conductor - Solid/Stranded, Plain /Tinned


Cables for re conductor, heat barrier, XLPE, LSZH Heat Barrier - Mica Tape Conductor
Glass Mica Tape
hazardous/ prone inner sheath G.S. wire and LSZH Insulation - XLPE Insulation

areas outer sheath as per IS 7098-I/ BS Innersheath - LSZH Compound Inner Sheath
Armour
7846 testing as per IEC 331 & Armoured - G.S. Round Wire/ Flat Strip Outer Sheath

BS 6387 Outersheath - LSZH Compound


Solar cable for Trinned cooper XLPO insulated & Conductor - Flexible trinned copper Conductor -
Flexible trinned
Solar plant LSZH sheathed 1100V AC/ 1800V Insulation - Cross linked polyolen compound copper

DC as per TUV specications Sheath - XLPO/ LSZH Compound Insulation -


XLPO linked poly

2PFG - 1169/08-2007 compound

Sheath -
XLPO/ LSZH
compound

Copper Control Annealed electrolytic copper Conductor - Solid/Stranded, Plain /Tinned


Cables for Power conductor, PVC/XLPE insulated, Insulation - PVC/HR PVC/XLPE
Switch yard PVC sheathed 650/ 1100V grade Innersheath - PVC/HR PVC/FRLS/Zero Halogen Outer Sheath

Control / Relay as per IS: 1554-I & IS: 7098-I Unarmoured / Armoured - G.S. Round Wire / Armour

Inner Sheath
Equipment Sizes : Flat Strip Conductor

1.5 / 2.5 sq. mm upto 61 core Outersheath - PVC/HR PVC/FRLS/Zero Halogen Insulation

4 & 6 Sq. mm upto 4 core Additional Option : Overall shielding with Aluminum
mylar tape with 100% coverage & 25% overlap on
laid up cores for static noise rejection.
Telecom / Switch Annealed Copper conductor, Conductor - Tinned / Plain
board cables for PVC Insulated as per DOT TEC Insulation - PVC / HR PVC / Nylon Outer Sheath

Armour
Indoor Telephones Spec No: G/WIR-06/02 Innersheath - PVC/ HR PVC/ FRLS Unarmoured / Inner Sheath

Sizes : Armoured - G.S. round wire / Flat Strip Conductor

Insulation
0.4 / 0.5 / 0.6 / 0.7 / 0.9 mm Outer sheath - PVC/HR PVC/FRLS
AdditIonal Option - Individual / Overall pair/
Shielding / Screening
Coaxial cables for Available in specied RG & UR Conductor - Plain / Tinned / Copper Clad Steel /
Telcom / icrowave Series as per MIL-C-17 / BS: 2316 Silver Plated P.E. Insulation

/ CATV / MATV / IS: 5608 / IS: 11967 Insulation - Solid / Foam / Semi air spaced
Sheath
industry Sizes : Suitable for Impedance Screen - Single / Double braid
of 50 / 75 / 100 / 125 ohms Sheath - PVC / HR PVC / FRLS / P.E Braid
Cable range at a glance
Application Type & Size Options Cross Sectional View
Flat cables for Stranded Plain copper, PVC insulated & PVC Insulation - PVC / HR PVC Insulation

Submersible sheathed of1.1kV grade as per IS: 694 Sheathing - PVC / HR PVC Conductor

Pumps & Motors Sizes : 3 core - 1.5 to 50 sq. mm Sheath

Instrumentation PVC Sheathed 225/650/ 1100 V grade Conductor - Standed / Solid, plain / tinned
Signal Cables for cables as per BS: 5308 / DIN VDE 0815 & Insulation - PVC / HR PVC / P.E / Zero Halogen
Process control & 816 / IS: 1554 / IEC: 189 Shielding - Individual Pair / over all pairs Drain Wire
Outer Sheath
Armour
Instrumentation Sizes: Drain wire - Solid Stranded Inner Sheath

Drain Wire
0.5/0.75/1.0/1.5 sq. mm Innersheath - PVC / HR PVC Zero Halogen Individual Pair Shield

Unarmoured/Armoured-G.S. Round Wire, Flat Conductor


Insulation

Strip Outersheath - PVC / HR PVC/ FRLS /


Zero Halogen Compound
Flexible & Cord Multistrand, exible, bright annealed Insulation - PVC / HR PVC / FRLS /
Cables for electrolytic copper conductor, PVC insulated Zero Halogen Conductor
Insulation

appliances, and sheathed upto 1100V as per IS:694 Unsheathed /Sheathed - PVC / HR PVC / Filler

Sheath
Machine Tools & Sizes : Single, Two, Three or FRLS
Equipment Wiring Four core upto 25 sq. mm

Wiring Cables for Multistrand Flexible, upto 1100V grade PVC Conductor - Bright Annealed Copper
Insulation
electrical industry Cables as per IS: 694 Insulation - PVC/ HR PVC/ FRLS PVC /
Sizes : Zero Halogen Conductor

Single core 1.0 - 630 sq. mm

Energy Cables PVC Flexible Cables upto 1.1kv grade Conductor - Stranded / annealed Copper
for Power Supply as per IS:694 Insulation
to Telephone Sizes : FR - Flame retardant PVC Color Skin

Exchanges / UPS / 1.0 upto 240 sq. mm Single / Multi Core Insulated industrial cables Natural PVC

Battery Backup / 1100V with S3 features Multistrand Flexible


Copper Conductor
Equipments
FR-LSH PVC Insulated
industrial cables 1100V

Energy Cables Flexible Cables upto 1.1kv grade Conductor - Stranded / annealed Copper
for Power Supply as per IS:694 Insulation-HFFR Insulated industrial cables Color Skin

to Telephone Sizes : 1100V Natural PVC

Exchanges / UPS / 1.0 upto 240 sq. mm Single / Multi Core Multistrand Flexible
Copper Conductor
Battery Backup /
Equipments

Air Field Lighting Stranded plain annealed copper, PVC Insulation - PVC / XLPE
Cables insulated & PVC sheathed of 5 kV grade Insulation

Sizes : Conductor

Single core 6 /16 sq.mm and 2 x 6, 16 & 25 Sheath

FS Wire Flexible Cables upto 450/750V Conductor - Stranded Flexible Copper Color Skin

generally to BS 7211 Insulation - Glass mica tape & HFFR Natural PVC

Sizes : Compound Glass Mica tape

1.0 upto 240 sq. mm Single Core Multistrand Flexible


Copper Conductor

Inside View - Cable Factory


LT POWER &
CONTROL CABLE

LT POWER & CONTROL CABLE


FEATURES

XLPE INSULATED CABLE PVC INSULATED CABLE


s (IGHERCURRENTRATING s (IGHDIELECTRICSTRENGTHRESISTANCETO$#VOLTAGEEFFECTS
ANDEMERGENCYOVERLOADRATING s (IGHMECHANICALSTRENGTHRESISTANCETOABRASION VIBRATIONAGEING
s 3UPEROIRSHORTCIRCUITRATING s 2ESISTANTTOMOSTACIDS ALKALIES TOTEMPORARYCONTACTWITHSOLVENTS
s ,OWDIELECTRICLOSS OILSANDLIQUIDFLUIDS
s -UCHBETTERINSULATIONRESISTANCE s &LAMERETARDANT DOESNOTSUPPORTCOMBUSTIONANDSELFEXTINGUISHING
s 2ESISTANTTOCHEMICALCORROSSIVEGASESETC
s "ETTERRESISTANCETOSURGECURRENTS
s -UCHLONGERLIFEOFTHECABLES

INSULATED MATERIAL APPLICABLE STANDARD


s 8,0% s )30ART 
s 06# s )30ART 
LT/HT Power & Control Cables

Table - 1
TECHNICAL DETAILS FOR HAVELLS 1.1 KV
SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, PVC INSULATED, UN-ARMOURED CABLES
Cable Code : AYY/YY
Physical Parameters Ref Specication : IS 1554 Part-1

Size Approx. Weight of Cable


Minimum No. of Strand in Conductor Nominal Insulation Nominal Outer Approx. Over-
(Cross Sectional With Al'm Cond. With Al'm Cond.
Thickness Sheath Thickness all Dia of Cable
Area) Aluminium Copper AYY YY
Sqmm No's No's mm mm mm Kg/Km Kg/Km
4 1/3 1/3 1.00 1.80 8 80 100
6 1/3 1/3 1.00 1.80 9 90 120
10 1/7 6 1.00 1.80 10 110 170
16 6 6 1.00 1.80 10 150 250
25 6 6 1.20 1.80 12 200 350
35 6 6 1.20 1.80 13 250 450
50 6 6 1.40 1.80 15 300 600
70 12 12 1.40 1.80 16 400 800
95 15 15 1.60 1.80 18 500 1050
120 15 18 1.60 2.00 20 600 1300
150 15 18 1.80 2.00 22 700 1600
185 30 30 2.00 2.00 24 850 1950
240 30 34 2.20 2.00 27 1100 2500
300 30 34 2.40 2.00 30 1300 3100
400 53 53 2.60 2.20 34 1700 3950
500 53 53 3.00 2.20 37 2100 5000
630 53 53 3.40 2.40 42 2700 6450
800 53 53 3.40 2.40 46 3250 8050
1000 53 53 3.40 2.60 50 3950 9950
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
1
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular, 16 Sq.mm and
above - Stranded Compacted Circular
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm and above - Stranded Compacted Circular
2 Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Colour : Black
3 Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Size Normal Current Rating Short Circuit Current
Max. Conductor Approx. Conductor Reactance of Capacitance
(Cross Rating for 1 Second
D.C.Resistance at 20 C A.C.Resistance at 70 C Cable at 50 of Cable For Aluminium Conductor For Copper Conductor
Sectional Duration
Hz (Approx.) (Approx.)
Area) Aluminium Copper Aluminium Copper Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
4 7.41 4.61 8.89 5.53 0.140 0.58 39 38 35 0.304 0.460
6 4.61 3.08 5.53 3.70 0.127 0.68 39 37 35 49 48 44 0.456 0.690
10 3.08 1.83 3.70 2.20 0.118 0.83 51 51 47 65 64 60 0.760 1.15
16 1.91 1.15 2.29 1.38 0.110 1.01 66 65 64 85 83 82 1.22 1.84
25 1.20 0.727 1.44 0.87 0.105 1.05 86 84 84 110 110 110 1.90 2.88
35 0.868 0.524 1.04 0.63 0.100 1.22 100 100 105 130 125 130 2.66 4.03
50 0.641 0.387 0.769 0.464 0.098 1.22 120 115 130 155 150 165 3.80 5.75
70 0.443 0.268 0.532 0.322 0.091 1.43 140 135 155 190 175 205 5.32 8.05
95 0.320 0.193 0.384 0.232 0.088 1.47 175 155 190 220 200 245 7.22 10.90
120 0.253 0.153 0.304 0.184 0.086 1.62 195 170 220 250 220 280 9.12 13.80
150 0.206 0.1240 0.247 0.1488 0.085 1.62 220 190 250 280 245 320 11.40 17.30
185 0.164 0.0991 0.197 0.1189 0.084 1.62 240 210 290 305 260 370 14.10 21.30
240 0.125 0.0754 0.151 0.0912 0.082 1.72 270 225 335 345 285 425 18.20 27.30
300 0.100 0.0601 0.122 0.0733 0.080 1.74 295 245 380 375 310 475 22.80 34.50
400 0.0778 0.0470 0.0961 0.0580 0.080 1.81 325 275 435 400 335 550 30.40 46.00
500 0.0605 0.0366 0.0759 0.0459 0.079 1.86 345 295 480 425 355 590 38.00 57.50
630 0.0469 0.0283 0.0610 0.0368 0.077 1.87 390 320 550 470 375 660 47.90 72.50
800 0.0367 0.0221 0.0503 0.0303 0.077 1.98 450 380 610 530 425 725 60.80 92.00
1000 0.0291 0.0176 0.0422 0.0255 0.076 2.20 500 415 680 590 740 870 76.00 115.00
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

12
LT/HT Power & Control Cables

Table - 2
TECHNICAL DETAILS FOR HAVELLS 1.1 KV
TWO CORE, ALUMINIUM/COPPER CONDUCTOR, PVC INSULATED, UN-ARMOURED CABLES
Cable Code : AYY/YY
Physical Parameters Ref Specication : IS 1554 Part-1
Approx. Weight of Cable
Size Minimum No. of Strand in Minimum
Conductor Nominal Insulation Nominal Outer Approx. Overall
(Cross Sectional Inner Sheath With Al'm Cond. With Cu Cond.
Thickness Sheath Thickness Dia of Cable
Area) Thickness
Aluminium Copper AYY YY
Sqmm No's No's mm mm mm mm Kg/Km Kg/Km
4 1/3 1/3 1.00 0.30 1.80 13 230 280
6 1/3 1/3 1.00 0.30 1.80 15 270 350
10 1/7 6 1.00 0.30 1.80 16 330 480
16 6 6 1.00 0.30 1.80 16 350 500
25 6 6 1.20 0.30 2.00 19 450 750
35 6 6 1.20 0.30 2.00 20 550 950
50 6 6 1.40 0.30 2.00 23 700 1250
70 12 12 1.40 0.30 2.00 25 850 1650
95 15 15 1.60 0.40 2.20 29 1150 2250
120 15 18 1.60 0.40 2.20 31 1300 2700
150 15 18 1.80 0.40 2.40 33 1600 3300
185 30 30 2.00 0.50 2.40 36 1900 4100
240 30 34 2.20 0.50 2.60 42 2450 5250
300 30 34 2.40 0.60 2.80 45 2950 6500
400 53 53 2.60 0.70 3.20 51 3800 8300
500 53 53 3.00 0.70 3.40 57 4750 10550
630 53 53 3.40 0.70 3.80 64 6000 13500
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
1 Shape of Conductor : For Al'm Cond. - For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
2
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Colour : Red & Black
3
Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
4 Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Size Normal Current Rating Short Circuit Current
Max. Conductor Approx. Conductor Reactance of Capacitance
(Cross Rating for 1 Second
D.C.Resistance at 20 C A.C.Resistance at 70 C Cable at 50 of Cable For Aluminium Conductor For Copper Conductor
Sectional Duration
Hz (Approx.) (Approx.)
Area) Aluminium Copper Aluminium Copper Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
4 7.41 4.61 8.89 5.53 0.098 0.23 32 27 27 41 35 35 0.304 0.460
6 4.61 3.08 5.53 3.70 0.096 0.28 40 34 35 50 44 45 0.456 0.690
10 3.08 1.83 3.70 2.20 0.091 0.34 55 45 47 70 58 60 0.760 1.15
16 1.91 1.15 2.29 1.38 0.085 0.40 70 58 59 90 75 78 1.22 1.84
25 1.20 0.727 1.44 0.87 0.083 0.42 90 76 78 115 97 105 1.90 2.88
35 0.868 0.524 1.04 0.63 0.082 0.48 110 92 99 140 120 125 2.66 4.03
50 0.641 0.387 0.769 0.464 0.082 0.49 135 115 125 165 145 155 3.80 5.75
70 0.443 0.268 0.532 0.322 0.076 0.56 160 140 150 205 180 195 5.32 8.05
95 0.320 0.193 0.384 0.232 0.076 0.58 190 170 185 240 215 230 7.22 10.90
120 0.253 0.153 0.304 0.184 0.075 0.63 210 190 210 275 235 265 9.12 13.80
150 0.206 0.1240 0.247 0.1488 0.074 0.63 240 210 240 310 270 305 11.40 17.30
185 0.164 0.0991 0.197 0.1189 0.074 0.64 275 240 275 350 300 350 14.10 21.28
240 0.125 0.0754 0.151 0.0912 0.073 0.67 320 275 325 405 345 410 18.20 27.60
300 0.100 0.0601 0.122 0.0733 0.073 0.68 355 305 365 450 385 465 22.80 34.50
400 0.0778 0.0470 0.0961 0.0580 0.072 0.70 385 345 420 490 485 530 30.40 46.00
500 0.0605 0.0366 0.0759 0.0459 0.072 0.70 425 380 475 540 460 605 38.00 57.50
630 0.0469 0.0283 0.0610 0.0368 0.072 0.70 465 415 540 640 550 785 47.90 72.55
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

13
LT/HT Power & Control Cables

Table - 3
TECHNICAL DETAILS FOR HAVELLS 1.1 KV
THREE CORE, ALUMINIUM/COPPER CONDUCTOR, PVC INSULATED, UN-ARMOURED CABLES
Cable Code : AYY/YY
Physical Parameters Ref Specication : IS 1554 Part-1
Approx. Weight of Cable
Size Minimum No. of Strand in Minimum
Conductor Nominal Insulation Nominal Outer Approx. Overall
(Cross Sectional Inner Sheath With Al'm Cond. With Cu Cond.
Thickness Sheath Thickness Dia of Cable
Area) Thickness
Aluminium Copper AYY YY
Sqmm No's No's mm mm mm mm Kg/Km Kg/Km
4 1/3 1/3 1.00 0.30 1.80 14 250 330
6 1/3 1/3 1.00 0.30 1.80 15 310 420
10 1/7 6 1.00 0.30 1.80 17 370 580
16 6 6 1.00 0.30 1.80 18 `450 700
25 6 6 1.20 0.30 2.00 21 600 1050
35 6 6 1.20 0.30 2.00 23 700 1350
50 6 6 1.40 0.30 2.00 26 900 1750
70 12 12 1.40 0.40 2.20 29 1200 2400
95 15 15 1.60 0.40 2.20 33 1500 3200
120 15 18 1.60 0.40 2.20 36 1800 3900
150 15 18 1.80 0.50 2.40 40 2200 4800
185 30 30 2.00 0.50 2.60 43 2700 5950
240 30 34 2.20 0.60 2.80 49 3550 7750
300 30 34 2.40 0.60 3.00 54 4200 9600
400 53 53 2.60 0.70 3.40 61 5350 12200
500 53 53 3.00 0.70 3.60 69 6750 15500
630 53 53 3.40 0.70 4.00 77 8550 19900
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
1
Shape of Conductor : For Al'm Cond. - For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular, 16
Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular, 16
Sq.mm and above - Stranded Compacted Shaped
2 Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Colour : Red, Yelow & Blue
3 Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
4 Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Size Normal Current Rating Short Circuit Current
Max. Conductor Approx. Conductor Reactance of Capacitance
(Cross Rating for 1 Second
D.C.Resistance at 20 C A.C.Resistance at 70 C Cable at 50 of Cable For Aluminium Conductor For Copper Conductor
Sectional Duration
Hz (Approx.) (Approx.)
Area) Aluminium Copper Aluminium Copper Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
4 7.41 4.61 8.89 5.53 0.098 0.23 28 23 23 36 30 30 0.304 0.460
6 4.61 3.08 5.53 3.70 0.096 0.28 35 30 30 45 38 39 0.456 0.690
10 3.08 1.83 3.70 2.20 0.091 0.34 46 39 40 60 50 52 0.760 1.15
16 1.91 1.15 2.29 1.38 0.085 0.40 60 50 51 77 64 66 1.22 1.84
25 1.20 0.727 1.44 0.87 0.083 0.42 76 63 70 99 81 90 1.90 2.88
35 0.868 0.524 1.04 0.63 0.082 0.48 92 77 86 120 99 110 2.66 4.03
50 0.641 0.387 0.769 0.464 0.082 0.49 110 95 105 145 125 135 3.80 5.75
70 0.443 0.268 0.532 0.322 0.076 0.56 135 115 130 175 150 165 5.32 8.05
95 0.320 0.193 0.384 0.232 0.076 0.58 165 140 155 210 175 200 7.22 10.90
120 0.253 0.153 0.304 0.184 0.075 0.63 185 155 180 240 195 230 9.12 13.80
150 0.206 0.1240 0.247 0.1488 0.074 0.63 210 175 205 270 225 265 11.40 17.30
185 0.164 0.0991 0.197 0.1189 0.074 0.64 235 200 240 300 255 305 14.10 21.30
240 0.125 0.0754 0.151 0.0912 0.073 0.67 275 235 280 345 295 355 18.20 27.60
300 0.100 0.0601 0.122 0.0733 0.073 0.68 305 260 315 385 335 400 22.80 34.50
400 0.0778 0.0470 0.0961 0.0580 0.072 0.70 335 290 375 425 360 435 30.40 46.00
500 0.0605 0.0366 0.759 0.0459 0.072 0.70 370 320 425 470 390 520 38.00 57.50
630 0.0469 0.0283 0.0610 0.0368 0.072 0.70 405 350 480 555 470 675 47.90 72.50
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

14
LT/HT Power & Control Cables

Table - 4
TECHNICAL DETAILS FOR HAVELLS 1.1 KV, THREE & HALF CORE
ALUMINIUM/COPPER CONDUCTOR, PVC INSULATED, UN-ARMOURED CABLES
Cable Code : AYY/YY
Physical Parameters Ref Specication : IS 1554 Part-1
Approx. Weight of Cable
Size Minimum No. of Strand in Minimum
Conductor Nominal Insulation Nominal Outer Approx. Overall
(Cross Sectional Inner Sheath With Al'm Cond. With Cu Cond.
Thickness Sheath Thickness Dia of Cable
Area) Thickness
Aluminium Copper AYY YY
Sqmm No's No's mm mm mm mm Kg/Km Kg/Km
3X 25+16 6/6 6/6 1.20/1.00 0.30 2.00 23 700 1250
3X35+16 6/6 6/6 1.20/1.00 0.30 2.00 25 800 1550
3X 50+25 6/6 6/6 1.40/1.20 0.30 2.20 28 1050 2050
3X70+35 12/6 12/6 1.40/1.20 0.40 2.20 32 1400 2800
3X95 +50 15/6 15/6 1.60/1.40 0.40 2.20 36 1800 3700
3X120+70 15/12 18/12 1.60/1.40 0.50 2.40 39 2200 4700
3X150+70 15/12 18/12 1.80/1.40 0.50 2.40 43 2550 5550
3X 185+95 30/15 30/15 2.00/1.60 0.50 2.40 47 3150 6900
3X240+120 30/15 34/18 2.20/1.60 0.60 3.00 53 4050 8950
3X300+150 30/15 34/18 2.40/1.80 0.60 3.20 58 4900 11100
3X400+185 53/30 53/30 2.60/2.00 0.70 3.40 64 6150 14000
3X500+240 53/30 53/34 3.00/2.20 0.70 3.80 76 7900 18050
3X630+300 53/30 53/34 3.40/2.40 0.70 4.00 84 9900 22950
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
1 Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
Shape of Conductor : For Al'm Cond. - For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
2
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Colour : Red, Yelow, Blue & Black
3
Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
4 Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Reactance Normal Current Rating Short Circuit Current
Size Max. Conductor Approx. Conductor Capacitance
of Cable Rating for 1 Second
(Cross D.C.Resistance at 20 C A.C.Resistance at 70 C of Cable For Aluminium Conductor For Copper Conductor
at 50 Hz Duration
Sectional Area) (Approx.)
Aluminium Copper Aluminium Copper (Approx.) Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
3X25+16 1.20 0.727 1.44 0.87 0.083 0.42 76 63 70 99 81 90 1.90 2.88
3X35+16 0.868 0.524 1.04 0.63 0.082 0.48 92 77 86 120 99 110 2.66 4.03
3X50+25 0.641 0.387 0.769 0.464 0.082 0.49 110 95 105 145 125 135 3.80 5.75
3X70+35 0.443 0.268 0.532 0.322 0.076 0.56 135 115 130 175 150 165 5.32 8.05
3X95+50 0.320 0.193 0.384 0.232 0.076 0.58 165 140 155 210 175 200 7.22 10.90
3X120+70 0.253 0.153 0.304 0.184 0.075 0.63 185 155 180 240 195 230 9.12 13.80
3X150+70 0.206 0.1240 0.247 0.1488 0.074 0.63 210 175 205 270 225 265 11.40 17.30
3X185+95 0.164 0.0991 0.197 0.1189 0.074 0.64 235 200 240 300 255 305 14.10 21.30
3X240+120 0.125 0.0754 0.151 0.0912 0.073 0.67 275 235 280 345 295 355 18.20 27.60
3X300+150 0.100 0.0601 0.122 0.0733 0.073 0.68 305 260 315 385 335 400 22.80 34.50
3X400+185 0.0778 0.0470 0.0961 0.0580 0.072 0.70 335 290 375 425 360 435 30.40 46.00
3X500+240 0.0605 0.0366 0.0759 0.0459 0.072 0.70 370 320 425 470 390 520 38.00 57.50
3X630+300 0.0469 0.0283 0.0610 0.0368 0.072 0.70 405 350 480 555 470 675 47.90 72.50
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

15
LT/HT Power & Control Cables

Table - 5
TECHNICAL DETAILS FOR HAVELLS 1.1 KV
FOUR CORE, ALUMINIUM/COPPER CONDUCTOR, PVC INSULATED, UN-ARMOURED CABLES
Cable Code : AYY/YY
Physical Parameters Ref Specication : IS 1554 Part-1
Approx. Weight of Cable
Size Minimum No. of Strand in Nominal Insulation Minimum Nominal Outer Approx. Overall
(Cross Sectional Conductor With Al'm Cond. With Cu Cond.
Thickness Inner Sheath Sheath Thickness Dia of Cable
Area)
Thickness
Aluminium Copper AYY YY
Sqmm No's No's mm mm mm mm Kg/Km Kg/Km
4 1/3 1/3 1.00 0.30 1.80 15 290 400
6 1/3 1/3 1.00 0.30 1.80 17 350 510
10 1/7 6 1.00 0.30 1.80 19 440 710
16 6 6 1.00 0.30 2.00 21 550 950
25 6 6 1.20 0.30 2.00 23 750 1350
35 6 6 1.20 0.30 2.00 26 900 1700
50 6 6 1.40 0.40 2.20 29 1200 2300
70 12 12 1.40 0.40 2.20 32 1500 3100
95 15 15 1.60 0.40 2.40 37 2000 4200
120 15 18 1.60 0.50 2.40 41 2400 5150
150 15 18 1.80 0.50 2.60 45 2900 6350
185 30 30 2.00 0.60 2.80 50 3600 7900
240 30 34 2.20 0.60 3.00 56 4550 10200
300 30 34 2.40 0.70 3.40 64 5650 12750
400 53 53 2.60 0.70 3.60 70 7000 16100
500 53 53 3.00 0.70 4.00 79 8950 20550
630 53 53 3.40 0.70 4.00 89 11200 26250
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
1 Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
2 Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Colour : Red, Yelow, Blue & Black
3 Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
4 Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Size Normal Current Rating Short Circuit Current
Max. Conductor Approx. Conductor Reactance of Capacitance
(Cross Rating for 1 Second
D.C.Resistance at 20 C A.C.Resistance at 70 C Cable at 50 of Cable For Aluminium Conductor For Copper Conductor
Sectional Duration
Hz (Approx.) (Approx.)
Area) Aluminium Copper Aluminium Copper Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
4 7.41 4.61 8.89 5.53 0.098 0.23 28 23 23 36 30 30 0.304 0.460
6 4.61 3.08 5.53 3.70 0.096 0.28 35 30 30 45 38 39 0.456 0.690
10 3.08 1.83 3.70 2.20 0.091 0.34 46 39 40 60 50 52 0.760 1.15
16 1.91 1.15 2.29 1.38 0.085 0.40 60 50 51 77 64 66 1.22 1.84
25 1.20 0.727 1.44 0.87 0.083 0.42 76 63 70 99 81 90 1.90 2.88
35 0.868 0.524 1.04 0.63 0.082 0.48 92 77 86 120 99 110 2.66 4.03
50 0.641 0.387 0.769 0.464 0.082 0.49 110 95 105 145 125 135 3.80 5.75
70 0.443 0.268 0.532 0.322 0.076 0.56 135 115 130 175 150 165 5.32 8.05
95 0.320 0.193 0.384 0.232 0.076 0.58 165 140 155 210 175 200 7.22 10.90
120 0.253 0.153 0.304 0.184 0.075 0.63 185 155 180 240 195 230 9.12 13.80
150 0.206 0.1240 0.247 0.1488 0.074 0.63 210 175 205 270 225 265 11.40 17.30
185 0.164 0.0991 0.197 0.1189 0.074 0.64 235 200 240 300 255 305 14.10 21.30
240 0.125 0.0754 0.151 0.0912 0.073 0.67 275 235 280 345 295 355 18.20 27.60
300 0.100 0.0601 0.122 0.0733 0.073 0.68 305 260 315 385 335 400 22.80 34.50
400 0.0778 0.0470 0.0961 0.0580 0.072 0.70 335 290 375 425 360 435 30.40 46.00
500 0.0605 0.0366 0.0759 0.0459 0.072 0.70 370 320 425 470 390 520 38.00 57.50
630 0.0469 0.0283 0.0610 0.0368 0.072 0.70 405 350 480 555 470 675 47.90 72.50
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

16
LT/HT Power & Control Cables

Table - 6
TECHNICAL DETAILS FOR HAVELLS 1.1 KV
SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, PVC INSULATED, ARMOURED CABLES
Ref Specication : IS 1554 Part-1
Physical Parameters Cable Code : AYFaY/YFaY, AYWaY/YWaY
Flat Strip Armoured (AYFaY/YFaY) Round Wire Armoured (AYWaY/YWaY)
Size Minimum No. of Approx. Weight of Cable Approx. Weight of Cable
Nominal Nominal Minimum Nominal Minimum
(Cross Strand in Conductor Approx. With Al'm Approx. With Al'm
Insulation Armour Outer With Cu Dia of Outer With Cu
Sectional Overall Dia Overall Dia
Thickness Strip Sheath Cond. Cond. Armor Sheath Cond. Cond.
Area) of Cable of Cable
Aluminium Copper Dimension Thickness AYFaY YFaY Wire Thickness AYWaY YWaY
Sqmm No's No's mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
4 1/3 1/3 1.30 N/A N/A N/A N/A N/A 1.40 1.24 11 130 160
6 1/3 1/3 1.30 N/A N/A N/A N/A N/A 1.40 1.24 12 150 190
10 1/7 6 1.30 N/A N/A N/A N/A N/A 1.40 1.24 13 170 240
16 6 6 1.30 N/A N/A N/A N/A N/A 1.40 1.24 13 250 300
25 6 6 1.50 N/A N/A N/A N/A N/A 1.40 1.24 15 300 450
35 6 6 1.50 N/A N/A N/A N/A N/A 1.40 1.24 16 350 550
50 6 6 1.70 N/A N/A N/A N/A N/A 1.40 1.24 17 400 700
70 12 12 1.70 N/A N/A N/A N/A N/A 1.40 1.40 19 500 900
95 15 15 1.90 4 X 0.80 1.40 20 600 1150 1.60 1.40 22 700 1250
120 15 18 1.90 4 X 0.80 1.40 22 700 1400 1.60 1.40 23 800 1450
150 15 18 2.10 4 X 0.80 1.40 23 800 1700 1.60 1.40 25 900 1750
185 30 30 2.30 4 X 0.80 1.40 25 1000 2050 1.60 1.40 27 1050 2150
240 30 34 2.50 4 X 0.80 1.40 28 1200 2600 1.60 1.56 30 1350 2750
300 30 34 2.70 4 X 0.80 1.56 31 1500 3250 1.60 1.56 33 1600 3350
400 53 53 3.00 4 X 0.80 1.56 35 1850 4100 2.00 1.56 38 2050 4300
500 53 53 3.40 4 X 0.80 1.56 39 2300 5150 2.00 1.72 42 2550 5400
630 53 53 3.90 4 X 0.80 1.72 44 2900 6650 2.00 1.88 46 3200 6950
800 53 53 3.90 4 X 0.80 1.88 48 3550 8350 2.00 1.88 51 3800 8600
1000 53 53 3.90 4 X 0.80 2.04 51 4250 10250 2.50 2.04 55 4700 10700
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.
Cross-sectional view
Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Circular
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm and above - Stranded Compacted Circular
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Colour : Black
Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Armouring : Single Layer of Aluminium Round Wire / Flat Strip
Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement
Electrical Parameters
Size Normal Current Rating Short Circuit Current
Max. Conductor Approx. Conductor Reactance of Capacitance
(Cross Rating for 1 Second
D.C.Resistance at 20 C A.C.Resistance at 70 C Cable at 50 of Cable For Aluminium Conductor For Copper Conductor
Sectional Duration
Hz (Approx.) (Approx.)
Area) Aluminium Copper Aluminium Copper Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
4 7.41 4.61 8.89 5.53 0.157 0.48 31 30 27 39 38 35 0.304 0.460
6 4.61 3.08 5.53 3.70 0.148 0.56 39 37 35 49 48 44 0.456 0.690
10 3.08 1.83 3.70 2.20 0.138 0.67 51 51 47 65 64 60 0.760 1.15
16 1.91 1.15 2.29 1.38 0.128 0.81 66 65 64 85 83 82 1.22 1.84
25 1.20 0.727 1.44 0.87 0.120 0.87 86 84 84 110 110 110 1.90 2.88
35 0.868 0.524 1.04 0.63 0.114 1.00 100 100 105 130 125 130 2.66 4.03
50 0.641 0.387 0.769 0.464 0.110 1.03 120 115 130 155 150 165 3.80 5.75
70 0.443 0.268 0.532 0.322 0.103 1.21 140 135 155 190 175 205 5.32 8.05
95 0.320 0.193 0.384 0.232 0.101 1.27 175 155 190 220 200 245 7.22 10.90
120 0.253 0.153 0.304 0.184 0.096 1.42 195 170 220 250 220 280 9.12 13.80
150 0.206 0.1240 0.247 0.1488 0.094 1.42 220 190 250 280 245 320 11.40 17.30
185 0.164 0.0991 0.197 0.1189 0.092 1.44 240 210 290 305 260 370 14.10 21.30
240 0.125 0.0754 0.151 0.0912 0.090 1.53 270 225 335 345 285 425 18.20 27.60
300 0.100 0.0601 0.122 0.0733 0.088 1.56 295 245 380 375 310 475 22.80 34.50
400 0.0778 0.0470 0.0961 0.0580 0.088 1.59 325 275 435 400 335 550 30.40 46.00
500 0.0605 0.0366 0.076 0.0459 0.087 1.67 345 295 480 425 355 590 38.00 57.50
630 0.0469 0.0283 0.0610 0.0368 0.086 1.67 390 320 550 470 375 660 47.88 72.50
800 0.0367 0.0221 0.0503 0.0303 0.083 1.75 450 380 610 530 423 725 60.80 92.00
1000 0.0291 0.0176 0.0422 0.0255 0.082 1.94 500 414 680 590 471 870 76.00 115.00
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

17
LT/HT Power & Control Cables

Table - 7
TECHNICAL DETAILS FOR HAVELLS 1.1 KV
TWO CORE, ALUMINIUM/COPPER CONDUCTOR, PVC INSULATED, ARMOURED CABLE
Ref Specication : IS 1554 Part-1
Physical Parameters Cable Code : AYFY/YFY, AYWY/YWY
Flat Strip Armoured (AYFY/YFY) Round Wire Armoured (AYWaY/YWaY)
Size Minimum No. of Nominal Minimum Approx. Weight of Cable Approx. Weight of Cable
Minimum Approx. Nominal Minimum Approx.
Nominal
(Cross Strand in Conductor Insulation Inner Outer Overall With Al'm With Cu Dia of Outer Overall With Al'm With Cu
Armour Strip Cond. Cond. Cond. Cond.
Sectional Thickness Sheath Sheath Dia of Armor Sheath Dia of
Dimension
Area) Aluminium Copper Thickness Thickness Cable AYFY YFY Wire Thickness Cable AYWY YWY
Sqmm No's No's mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
4 1/3 1/3 1.00 0.30 N/A N/A N/A N/A N/A 1.40 1.24 15 460 520
6 1/3 1/3 1.00 0.30 N/A N/A N/A N/A N/A 1.40 1.24 16 530 620
10 1/7 6 1.00 0.30 N/A N/A N/A N/A N/A 1.40 1.24 18 620 780
16 6 6 1.00 0.30 4 X 0.80 1.40 17 500 700.0 1.60 1.40 18 700 850
25 6 6 1.20 0.30 4 X 0.80 1.40 19 600 950.0 1.60 1.40 21 850 1150
35 6 6 1.20 0.30 4 X 0.80 1.40 21 750 1150.0 1.60 1.40 22 950 1350
50 6 6 1.40 0.30 4 X 0.80 1.40 23 900 1450.0 1.60 1.56 25 1200 1750
70 12 12 1.40 0.30 4 X 0.80 1.56 26 1100 1900.0 1.60 1.56 27 1400 2200
95 15 15 1.60 0.40 4 X 0.80 1.56 29 1400 2500.0 2.00 1.56 32 1900 3000
120 15 18 1.60 0.40 4 X 0.80 1.56 31 1600 3000.0 2.00 1.72 34 2150 3550
150 15 18 1.80 0.40 4 X 0.80 1.72 34 1900 3650.0 2.00 1.72 36 2500 4200
185 30 30 2.00 0.50 4 X 0.80 1.88 37 2300 4450.0 2.00 1.88 40 2950 5100
240 30 34 2.20 0.50 4 X 0.80 2.04 42 2850 5700.0 2.50 2.04 46 3850 6700
300 30 34 2.40 0.60 4 X 0.80 2.20 46 3400 6950.0 2.50 2.20 49 4550 8100
400 53 53 2.60 0.70 4 X 0.80 2.36 51 4200 8750.0 3.15 2.52 56 6050 10600
500 53 53 3.00 0.70 4 X 0.80 2.68 57 5250 11050.0 3.15 2.84 62 7350 13150
630 53 53 3.40 0.70 4 X 0.80 2.84 64 6550 14050.0 4.00 3.00 70 9750 17250
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
1 Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular, 16 Sq.mm
and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
2
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Colour : Red & Black
3
Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
4
Armouring : Single Layer of Galvanized Steel Round Wire / Flat Strip
5
Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement
Electrical Parameters
Size Normal Current Rating Short Circuit Current
Max. Conductor Approx. Conductor Reactance of Capacitance
(Cross Rating for 1 Second
D.C.Resistance at 20 C A.C.Resistance at 70 C Cable at 50 of Cable For Aluminium Conductor For Copper Conductor
Sectional Duration
Hz (Approx.) (Approx.)
Area) Aluminium Copper Aluminium Copper Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
4 7.41 4.61 8.89 5.53 0.098 0.23 32 27 27 41 35 35 0.304 0.460
6 4.61 3.08 5.53 3.70 0.096 0.28 40 34 35 50 44 45 0.456 0.690
10 3.08 1.83 3.70 2.20 0.091 0.34 55 45 47 70 58 60 0.760 1.150
16 1.91 1.15 2.29 1.38 0.085 0.40 70 58 59 90 75 78 1.22 1.840
25 1.20 0.727 1.44 0.870 0.083 0.42 90 76 78 115 97 105 1.90 2.880
35 0.868 0.524 1.04 0.630 0.082 0.48 110 92 99 140 120 125 2.66 4.030
50 0.641 0.387 0.769 0.464 0.082 0.49 135 115 125 165 145 155 3.80 5.750
70 0.443 0.268 0.532 0.322 0.076 0.56 160 140 150 205 180 195 5.32 8.050
95 0.320 0.193 0.384 0.232 0.076 0.58 190 170 185 240 215 230 7.22 10.90
120 0.253 0.153 0.304 0.184 0.075 0.63 210 190 210 275 235 265 9.12 13.80
150 0.206 0.1240 0.247 0.1488 0.074 0.63 240 210 240 310 270 305 11.40 17.30
185 0.164 0.0991 0.197 0.1189 0.074 0.64 275 240 275 350 300 350 14.10 21.30
240 0.125 0.0754 0.151 0.0912 0.073 0.67 320 275 325 405 345 410 18.20 27.60
300 0.100 0.0601 0.122 0.0733 0.073 0.68 355 305 365 450 385 465 22.80 34.50
400 0.0778 0.0470 0.0961 0.0580 0.072 0.70 385 345 420 490 485 530 30.40 46.00
500 0.0605 0.0366 0.0759 0.0459 0.072 0.70 425 380 475 540 460 605 38.00 57.50
630 0.0469 0.0283 0.0610 0.0368 0.072 0.70 465 415 540 640 550 785 47.90 72.50
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

18
LT/HT Power & Control Cables

Table - 8
TECHNICAL DETAILS FOR HAVELLS 1.1 KV
THREE CORE, ALUMINIUM/COPPER CONDUCTOR, PVC INSULATED, ARMOURED CABLE
Ref Specication : IS 1554 Part-1
Physical Parameters Cable Code : AYFY/YFY, AYWY/YWY
Flat Strip Armoured (AYFY/YFY) Round Wire Armoured (AYWaY/YWaY)
Size Nominal Minimum Nominal Minimum Approx. Approx. Weight of Cable Approx. Weight of Cable
Minimum No. of Nominal Minimum Approx.
(Cross Strand in Conductor Insulation Inner Armour Outer Overall With Al'm With Cu Dia of Outer Overall With Al'm With Cu
Sectional Thickness Sheath Strip Sheath Dia of Cond. Cond. Armor Sheath Dia of Cond. Cond.
Area) Aluminium Copper Thickness Dimension Thickness Cable AYFY YFY Wire Thickness Cable AYWY YWY
Sqmm No's No's mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
4 1/3 1/3 1.00 0.30 N/A N/A N/A N/A N/A 1.40 1.24 16 460 540
6 1/3 1/3 1.00 0.30 N/A N/A N/A N/A N/A 1.40 1.24 17 530 650
10 1/7 6 1.00 0.30 N/A N/A N/A N/A N/A 1.40 1.40 19 620 840
16 6 6 1.00 0.30 4 X 0.80 1.40 19 600 900.0 1.60 1.40 21 850 1100
25 6 6 1.20 0.30 4 X 0.80 1.40 22 800 1250.0 1.60 1.40 23 1050 1500
35 6 6 1.20 0.30 4 X 0.80 1.40 23 950 1550.0 1.60 1.40 25 1200 1800
50 6 6 1.40 0.30 4 X 0.80 1.56 27 1200 2050.0 1.60 1.56 28 1500 2300
70 12 12 1.40 0.40 4 X 0.80 1.56 30 1500 2700.0 2.00 1.56 32 2000 3200
95 15 15 1.60 0.40 4 X 0.80 1.56 33 1850 3550.0 2.00 1.72 36 2450 4150
120 15 18 1.60 0.40 4 X 0.80 1.72 36 2200 4300.0 2.00 1.72 39 2800 4900
150 15 18 1.80 0.50 4 X 0.80 1.88 40 2650 5250.0 2.00 1.88 43 3350 5900
185 30 30 2.00 0.50 4 X 0.80 1.88 44 3150 6400.0 2.50 2.04 48 4300 7500
240 30 34 2.20 0.60 4 X 0.80 2.20 50 4000 8250.0 2.50 2.20 53 5250 9450
300 30 34 2.40 0.60 4 X 0.80 2.36 55 4800 10150.0 2.50 2.36 58 6150 11450
400 53 53 2.60 0.70 4 X 0.80 2.52 61 5950 12750.0 3.15 2.68 66 8200 14950
500 53 53 3.00 0.70 4 X 0.80 2.84 69 7450 16200.0 3.15 3.00 74 10000 18700
630 53 53 3.40 0.70 4 X 0.80 3.00 77 9300 20600.0 4.00 3.00 84 13150 24400
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
1
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular, 16 Sq.mm
and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
2
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Colour : Red, Yellow & Blue
3
Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
4
Armouring : Single Layer of Galvanized Steel Round Wire / Flat Strip
5
Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement
Electrical Parameters
Size Normal Current Rating Short Circuit Current
Max. Conductor Approx. Conductor Reactance of Capacitance
(Cross Rating for 1 Second
D.C.Resistance at 20 C A.C.Resistance at 70 C Cable at 50 of Cable For Aluminium Conductor For Copper Conductor
Sectional Duration
Hz (Approx.) (Approx.)
Area) Aluminium Copper Aluminium Copper Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
4 7.41 4.61 8.89 5.53 0.098 0.23 28 23 23 36 30 30 0.304 0.460
6 4.61 3.08 5.53 3.70 0.096 0.28 35 30 30 45 38 39 0.456 0.690
10 3.08 1.83 3.70 2.20 0.091 0.34 46 39 40 60 50 52 0.760 1.15
16 1.91 1.15 2.29 1.38 0.085 0.40 60 50 51 77 64 66 1.22 1.84
25 1.20 0.727 1.44 0.87 0.083 0.42 76 63 70 99 81 90 1.90 2.88
35 0.868 0.524 1.04 0.63 0.082 0.48 92 77 86 120 99 110 2.66 4.03
50 0.641 0.387 0.769 0.464 0.082 0.49 110 95 105 145 125 135 3.80 5.75
70 0.443 0.268 0.532 0.322 0.076 0.56 135 115 130 175 150 165 5.32 8.05
95 0.320 0.193 0.384 0.232 0.076 0.58 165 140 155 210 175 200 7.22 10.90
120 0.253 0.153 0.304 0.184 0.075 0.63 185 155 180 240 195 230 9.12 13.80
150 0.206 0.1240 0.247 0.1488 0.074 0.63 210 175 205 270 225 265 11.40 17.30
185 0.164 0.0991 0.197 0.1189 0.074 0.64 235 200 240 300 255 305 14.10 21.30
240 0.125 0.0754 0.151 0.0912 0.073 0.67 275 235 280 345 295 355 18.20 27.60
300 0.100 0.0601 0.122 0.0733 0.073 0.68 305 260 315 385 335 400 22.80 34.50
400 0.0778 0.0470 0.0961 0.0580 0.072 0.70 335 290 375 425 360 435 30.40 46.00
500 0.0605 0.0366 0.0759 0.0459 0.072 0.70 370 320 425 470 390 520 38.00 57.50
630 0.0469 0.0283 0.0610 0.0368 0.072 0.70 405 350 480 555 470 675 47.90 72.50
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

19
LT/HT Power & Control Cables

Table - 9
TECHNICAL DETAILS FOR HAVELLS 1.1 KV, THREE & HALF CORE
ALUMINIUM/COPPER CONDUCTOR, PVC INSULATED, ARMOURED CABLE
Ref Specication : IS 1554 Part-1
Physical Parameters Cable Code : AYFY/YFY, AYWY/YWY
Flat Strip Armoured (AYFY/YFY) Round Wire Armoured (AYWaY/YWaY)
Size Minimum No. of Nominal Minimum Nominal Minimum Approx. Approx. Weight of Cable Nominal Minimum Approx. Approx. Weight of Cable
(Cross Strand in Conductor Insulation Inner Armour Outer Overall With Al'm With Cu Dia of Outer Overall With Al'm With Cu
Sectional Thickness Sheath Strip Sheath Dia of Cond. Cond. Armor Sheath Dia of Cond. Cond.
Area) Aluminium Copper Thickness Dimension Thickness Cable AYFY YFY Wire Thickness Cable AYWY YWY
Sqmm No's No's mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
3X 25 +16 6/6 6/6 1.20/1.00 0.30 4 X 0.80 1.40 23 900 1450 1.60 1.40 25 1150 1700
3X35 +16 6/6 6/6 1.20/1.00 0.30 4 X 0.80 1.40 25 1050 1800 1.60 1.40 27 1350 2050
3X 50+25 6/6 6/6 1.40/1.20 0.30 4 X 0.80 1.56 29 1350 2350 2.00 1.56 30 1650 2600
3X70+35 12/6 12/6 1.40/1.20 0.40 4 X 0.80 1.56 32 1700 3100 2.00 1.56 34 2200 3600
3X95 +50 15/6 15/6 1.60/1.40 0.40 4 X 0.80 1.56 36 2150 4050 2.00 1.72 39 2800 4750
3X120+70 15/12 18/12 1.60/1.40 0.50 4 X 0.80 1.72 40 2550 5050 2.00 1.88 42 3300 5750
3X150+70 15/12 18/12 1.80/1.40 0.50 4 X 0.80 1.88 44 3000 6000 2.00 1.88 46 3750 6700
3X 185+95 30/15 30/15 2.00/1.60 0.50 4 X 0.80 2.04 48 3650 7400 2.50 2.04 51 4850 8650
3X240+120 30/15 34/18 2.20/1.60 0.60 4 X 0.80 2.2 53 4500 9400 2.50 2.36 57 5850 10800
3X300+150 30/15 34/18 2.40/1.80 0.60 4 X 0.80 2.36 58 5450 11650 3.15 2.52 63 7600 13800
3X400+185 53/30 53/30 2.60/2.00 0.70 4 X 0.80 2.68 64 6750 14600 3.15 2.68 69 9000 16850
3X500+240 53/30 53/34 3.00/2.20 0.70 4 X 0.80 2.84 76 8550 18700 4 3.00 83 12400 22500
3X630+300 53/30 53/34 3.40/2.40 0.70 4 X 0.80 3.00 84 10600 23700 4 3.00 91 14750 27800
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Colour : Red, Yellow, Blue & Black
Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Armouring : Single Layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Normal Current Rating Short Circuit Current
Size Max. Conductor Approx. Conductor Reactance of Capacitance
Rating for 1 Second
(Cross D.C.Resistance at 20 C A.C.Resistance at 70 C Cable at 50 of Cable For Aluminium Conductor For Copper Conductor
Duration
Sectional Area) Hz (Approx.) (Approx.)
Aluminium Copper Aluminium Copper Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
3X25+16 1.20 0.727 1.44 0.87 0.083 0.42 76 63 70 99 81 90 1.90 2.88
3X35+16 0.868 0.524 1.04 0.63 0.082 0.48 92 77 86 120 99 110 2.66 4.03
3X50+25 0.641 0.387 0.769 0.464 0.082 0.49 110 95 105 145 125 135 3.80 5.75
3X70+35 0.443 0.268 0.532 0.322 0.076 0.56 135 115 130 175 150 165 5.32 8.05
3X95+50 0.320 0.193 0.384 0.232 0.076 0.58 165 140 155 210 175 200 7.22 10.90
3X120+70 0.253 0.153 0.304 0.184 0.075 0.63 185 155 180 240 195 230 9.12 13.80
3X150+70 0.206 0.1240 0.247 0.1488 0.074 0.63 210 175 205 270 225 265 11.40 17.30
3X185+95 0.164 0.0991 0.197 0.1189 0.074 0.64 235 200 240 300 255 305 14.10 21.30
3X240+120 0.125 0.0754 0.151 0.0912 0.073 0.67 275 235 280 345 295 355 18.20 27.60
3X300+150 0.100 0.0601 0.122 0.0733 0.073 0.68 305 260 315 385 335 400 22.80 34.50
3X400+185 0.0778 0.0470 0.0961 0.0580 0.072 0.70 335 290 375 425 360 435 30.40 46.00
3X500+240 0.0605 0.0366 0.0759 0.0459 0.072 0.70 370 320 425 470 390 520 38.00 57.50
3X630+300 0.0469 0.0283 0.0610 0.0368 0.072 0.70 405 350 480 555 470 675 47.90 72.50
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

20
LT/HT Power & Control Cables

Table - 10
TECHNICAL DETAILS FOR HAVELLS 1.1 KV
FOUR CORE, ALUMINIUM/COPPER CONDUCTOR, PVC INSULATED, ARMOURED CABLES
Ref Specication : IS 1554 Part-1
Physical Parameters Cable Code : AYFY/YFY, AYWY/YWY
Flat Strip Armoured (AYFY/YFY) Round Wire Armoured (AYWaY/YWaY)
Size Minimum No. of Nominal Minimum Nominal Minimum Approx. Approx. Weight of Cable Approx. Weight of Cable
Nominal Minimum Approx.
(Cross Strand in Conductor Insulation Inner Armour Outer Overall With Al'm With Cu Dia of Outer Overall With Al'm With Cu
Sectional Thickness Sheath Strip Sheath Dia of Cond. Cond. Armor Sheath Dia of Cond. Cond.
Area) Aluminium Copper Thickness Dimension Thickness Cable AYFY YFY Wire Thickness Cable AYWY YWY
Sqmm No's No's mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
4 1/3 1/3 1.00 0.30 N/A N/A N/A N/A N/A 1.40 1.24 17 520 620
6 1/3 1/3 1.00 0.30 N/A N/A N/A N/A N/A 1.40 1.24 19 610 770
10 1/7 6 1.00 0.30 4 X 0.80 1.40 19 600 850 1.60 1.40 21 790 1060
16 6 6 1.00 0.30 4 X 0.80 1.40 21 750 1100.0 1.60 1.40 23 950 1350
25 6 6 1.20 0.30 4 X 0.80 1.40 24 950 1550.0 1.60 1.40 25 1200 1800
35 6 6 1.20 0.30 4 X 0.80 1.40 26 1150 2000.0 1.60 1.56 28 1450 2300
50 6 6 1.40 0.40 4 X 0.80 1.56 30 1450 2550.0 2.00 1.56 32 2000 3100
70 12 12 1.40 0.40 4 X 0.80 1.56 33 1850 3450.0 2.00 1.56 35 2400 4000
95 15 15 1.60 0.40 4 X 0.80 1.72 38 2350 4600.0 2.00 1.72 40 3000 5250
120 15 18 1.60 0.50 4 X 0.80 1.88 41 2800 5650.0 2.00 1.88 44 3500 6350
150 15 18 1.80 0.50 4 X 0.80 1.88 45 3300 6800.0 2.50 2.04 49 4500 7950
185 30 30 2.00 0.60 4 X 0.80 2.04 50 4000 8350.0 2.50 2.20 54 5350 9700
240 30 34 2.20 0.60 4 X 0.80 2.36 57 5100 10800.0 2.50 2.36 60 6500 12250
300 30 34 2.40 0.70 4 X 0.80 2.52 64 6200 13300.0 3.15 2.68 69 8500 15700
400 53 53 2.60 0.70 4 X 0.80 2.84 71 7650 16750.0 3.15 2.84 75 10200 19350
500 53 53 3.00 0.70 4 X 0.80 3.00 79 9600 21300.0 4.00 3.00 85 13550 25300
630 53 53 3.40 0.70 4 X 0.80 3.00 89 11700 27050.0 4.00 3.00 95 16350 31450
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Colour : Red, Yellow, Blue & Black
Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Armouring : Single Layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Size Normal Current Rating Short Circuit Current
Max. Conductor Approx. Conductor Reactance of Capacitance
(Cross Rating for 1 Second
D.C.Resistance at 20 C A.C.Resistance at 70 C Cable at 50 of Cable For Aluminium Conductor For Copper Conductor
Sectional Duration
Hz (Approx.) (Approx.)
Area) Aluminium Copper Aluminium Copper Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
4 7.41 4.61 8.89 5.53 0.098 0.23 28 23 23 36 30 30 0.304 0.460
6 4.61 3.08 5.53 3.70 0.096 0.28 35 30 30 45 38 39 0.456 0.690
10 3.08 1.83 3.70 2.20 0.091 0.34 46 39 40 60 50 52 0.760 1.15
16 1.91 1.15 2.29 1.38 0.085 0.40 60 50 51 77 64 66 1.22 1.84
25 1.20 0.727 1.44 0.87 0.083 0.42 76 63 70 99 81 90 1.90 2.88
35 0.868 0.524 1.04 0.63 0.082 0.48 92 77 86 120 99 110 2.66 4.03
50 0.641 0.387 0.769 0.464 0.082 0.49 110 95 105 145 125 135 3.80 5.75
70 0.443 0.268 0.532 0.322 0.076 0.56 135 115 130 175 150 165 5.32 8.05
95 0.320 0.193 0.384 0.232 0.076 0.58 165 140 155 210 175 200 7.22 10.90
120 0.253 0.153 0.304 0.184 0.075 0.63 185 155 180 240 195 230 9.12 13.80
150 0.206 0.1240 0.247 0.1488 0.074 0.63 210 175 205 270 225 265 11.40 17.30
185 0.164 0.0991 0.197 0.1189 0.074 0.64 235 200 240 300 255 305 14.10 21.30
240 0.125 0.0754 0.151 0.0912 0.073 0.67 275 235 280 345 295 355 18.20 27.60
300 0.100 0.0601 0.122 0.0733 0.073 0.68 305 260 315 385 335 400 22.80 34.50
400 0.0778 0.0470 0.0961 0.0580 0.072 0.70 335 290 375 425 360 435 30.40 46.00
500 0.0605 0.0366 0.0759 0.0459 0.072 0.70 370 320 425 470 390 520 38.00 57.50
630 0.0469 0.0283 0.0610 0.0368 0.072 0.70 405 350 480 555 470 675 47.90 72.50
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

21
LT/HT Power & Control Cables

Table - 11
TECHNICAL DETAILS FOR HAVELLS 1.1 KV 1.5 SQMM
COPPER CONDUCTOR, PVC INSULATED, ARMOURED / UNARMOURED CONTROL CABLES
Ref Specication : IS 1554 Part-1
Physical Parameters Cable Code : YY/YFY/YWY
Unarmoured (YY) Flat Strip Armoured (YFY) Round Wire Armoured (YWY)

No. Minimum Nominal Approx. Minimum Approx. Approx. Weight of Nominal Minimum Approx. Approx. Weight of
Approx. Dimen-
of Inner Outer Overall Dia of Outer Overall Dia of Cable Dia of Outer Overall Dia of Cable
Weight of Cable sion of
Cores Sheath Sheath Cable Sheath Cable Armour Sheath Cable
Armour
Thickness Thickness Solid Std. Soild Std. Thick- Soild Std. Soild Std. Wire Thick- Soild Std. Soild Std.
Strip
Cond. cond. Cond cond. ness Cond cond. Cond cond. ness Cond cond. Cond cond.
Nos mm mm mm mm Kg/Km Kg/Km mm mm mm mm Kg/Km Kg/Km mm mm mm mm Kg/Km Kg/Km
2 0.30 1.80 11 11 160 170 N/A N/A N/A N/A N/A N/A 1.40 1.24 13 13 340 360
3 0.30 1.80 11 12 190 200 N/A N/A N/A N/A N/A N/A 1.40 1.24 13 14 360 380
4 0.30 1.80 12 13 220 230 N/A N/A N/A N/A N/A N/A 1.40 1.24 14 14 400 420
5 0.30 1.80 13 14 260 270 N/A N/A N/A N/A N/A N/A 1.40 1.24 15 15 460 480
6 0.30 1.80 14 15 300 310 N/A N/A N/A N/A N/A N/A 1.40 1.24 16 16 510 530
7 0.30 1.80 14 15 280 300 N/A N/A N/A N/A N/A N/A 1.40 1.24 16 16 530 550
10 0.30 1.80 17 18 380 400 N/A N/A N/A N/A N/A N/A 1.40 1.40 19 20 700 740
12 0.30 1.80 18 18 430 450 4x0.8 1.24 18 19 620 640 1.60 1.40 20 21 810 850
14 0.30 1.80 18 19 490 500 4x0.8 1.40 19 20 680 730 1.60 1.40 21 22 880 940
16 0.30 1.80 19 20 540 560 4x0.8 1.40 20 21 760 780 1.60 1.40 22 23 970 1000
19 0.30 2.00 20 21 630 660 4x0.8 1.40 21 22 830 880 1.60 1.40 23 24 1060 1110
24 0.30 2.00 23 25 780 820 4x0.8 1.40 24 25 1020 1070 1.60 1.40 25 27 1220 1340
27 0.30 2.00 24 25 850 890 4x0.8 1.40 24 26 1110 1150 1.60 1.40 26 27 1360 1430
30 0.30 2.00 25 26 930 970 4x0.8 1.40 25 27 1180 1250 1.60 1.40 27 28 1450 1520
37 0.30 2.00 27 28 1100 1150 4x0.8 1.40 27 28 1380 1450 1.60 1.40 29 30 1690 1740
40 0.30 2.00 27 29 1170 1220 4x0.8 1.40 28 29 1460 1530 1.60 1.56 30 31 1780 1870
44 0.30 2.00 30 31 1290 1350 4x0.8 1.56 30 32 1630 1710 1.60 1.56 32 34 1950 2040
52 0.40 2.20 31 33 1520 1590 4x0.8 1.56 32 33 1850 1940 2.00 1.56 34 36 2390 2510
61 0.40 2.20 33 35 1740 1820 4x0.8 1.56 34 35 2090 2210 2.00 1.56 36 38 2660 2780
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
Conductor : Solid / Stranded Annealed Bare Copper as per Class-2 of IS: 8130; Options : Tinned
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Nominal Insulation Thickness : 0.80 mm
Core Identication : Upto 5 cores : By colour coding & Above 5 cores : By colour coding / Number printing on cores
as per IS : 1554 Part-1
Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Armouring : Single Layer of Aluminium Round Wire / Flat Strip
Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Normal Current Rating
Max. Reactance Short Circuit Current Rating for 1 Second
No. Approx. Conductor Capacitance For General Purpose For Heat Resisting
Conductor of Cable Duration
of A.C.Resistance of Cable Insulation Insulation
D.C.Resistance at 50 Hz
Cores (Approx.) For General Purpose For Heat Resisting
at 20 C at 70 C at 85 C (Approx.) Ground Duct Air Ground Duct Air
Insulation Insulation
No's Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
2 12.10 14.52 15.20 0.112 0.20 23 20 20 26 24 24 0.173 0.156
3 12.10 14.52 15.20 0.112 0.20 21 17 17 24 21 21 0.173 0.156
4 12.10 14.52 15.20 0.112 0.20 21 17 17 24 21 21 0.173 0.156
5 12.10 14.52 15.20 0.112 0.20 21 17 17 24 21 21 0.173 0.156
6 12.10 14.52 15.20 0.112 0.20 15 13 13 17 16 16 0.173 0.156
7 12.10 14.52 15.20 0.112 0.20 14 13 13 16 15 15 0.173 0.156
10 12.10 14.52 15.20 0.112 0.20 13 11 11 15 13 13 0.173 0.156
12 12.10 14.52 15.20 0.112 0.20 12 10 10 14 12 12 0.173 0.156
14 12.10 14.52 15.20 0.112 0.20 11 10 10 13 12 12 0.173 0.156
16 12.10 14.52 15.20 0.112 0.20 11 9 9 13 11 11 0.173 0.156
19 12.10 14.52 15.20 0.112 0.20 10 9 9 11 11 11 0.173 0.156
24 12.10 14.52 15.20 0.112 0.20 9 8 8 10 10 10 0.173 0.156
27 12.10 14.52 15.20 0.112 0.20 9 8 8 10 10 10 0.173 0.156
30 12.10 14.52 15.20 0.112 0.20 9 7 7 10 8 8 0.173 0.156
37 12.10 14.52 15.20 0.112 0.20 8 7 7 9 8 8 0.173 0.156
40 12.10 14.52 15.20 0.112 0.20 8 7 7 9 8 8 0.173 0.156
44 12.10 14.52 15.20 0.112 0.20 7 7 7 8 7 7 0.173 0.156
52 12.10 14.52 15.20 0.112 0.20 6 6 6 7 7 7 0.173 0.156
61 12.10 14.52 15.20 0.112 0.20 6 6 6 7 7 7 0.173 0.156
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

22
LT/HT Power & Control Cables

Table - 12
TECHNICAL DETAILS FOR HAVELLS 1.1 KV 2.5 SQMM
COPPER CONDUCTOR, PVC INSULATED, ARMOURED / UNARMOURED CONTROL CABLES
Ref. Spec. : IS :1554PART -1
Physical Parameters Cable Code : YY/YFY/YWY
Unarmoured (YY) Flat Strip Armoured (YFY) Round Wire Armoured (YWY)

No. Minimum Nominal Approx. Minimum Approx. Approx. Weight of Nominal Minimum Approx. Approx. Weight of
Approx. Weight of Dimen-
of Inner Outer Overall Dia of Outer Overall Dia of Cable Dia of Outer Overall Dia of Cable
Cable sion of
Cores Sheath Sheath Cable Sheath Cable Armour Sheath Cable
Armour
Thickness Thickness Solid Std. Soild Std. Thick- Soild Std. Soild Std. Wire Thick- Soild Std. Soild Std.
Strip
Cond. cond. Cond cond. ness Cond cond. Cond cond. ness Cond cond. Cond cond.
Nos mm mm mm mm Kg/Km Kg/Km mm mm mm mm Kg/Km Kg/Km mm mm mm mm Kg/Km Kg/Km
2 0.30 1.80 12 13 210 220 N/A N/A N/A N/A N/A N/A 1.40 1.24 14 14 410 440
3 0.30 1.80 13 13 250 260 N/A N/A N/A N/A N/A N/A 1.40 1.24 15 15 430 450
4 0.30 1.80 14 14 300 310 N/A N/A N/A N/A N/A N/A 1.40 1.24 16 16 500 520
5 0.30 1.80 15 15 360 360 N/A N/A N/A N/A N/A N/A 1.40 1.24 17 17 570 590
6 0.30 1.80 16 16 400 420 N/A N/A N/A N/A N/A N/A 1.40 1.24 18 18 630 660
7 0.30 1.80 16 16 390 400 N/A N/A N/A N/A N/A N/A 1.40 1.24 18 18 670 700
10 0.30 1.80 20 20 530 550 4x0.8 1.40 20 21 750 790 1.60 1.40 22 23 960 1010
12 0.30 2.00 21 21 620 650 4x0.8 1.40 21 22 820 870 1.60 1.40 23 24 1040 1100
14 0.30 2.00 21 22 700 730 4x0.8 1.40 22 23 920 970 1.60 1.40 24 24 1150 1190
16 0.30 2.00 22 23 780 810 4x0.8 1.40 23 24 1020 1050 1.60 1.40 25 26 1240 1300
19 0.30 2.00 24 25 890 930 4x0.8 1.40 24 25 1130 1190 1.60 1.40 26 27 1390 1450
24 0.30 2.00 27 29 1110 1150 4x0.8 1.40 28 29 1400 1470 1.60 1.56 30 31 1720 1790
27 0.30 2.00 28 29 1210 1260 4x0.8 1.40 28 30 1510 1580 1.60 1.56 30 32 1840 1920
30 0.30 2.00 29 30 1320 1380 4x0.8 1.56 30 31 1670 1750 1.60 1.56 31 33 1980 2060
37 0.40 2.20 32 33 1630 1700 4x0.8 1.56 32 34 1960 2050 2.00 1.56 34 36 2520 2620
40 0.40 2.20 33 34 1730 1800 4x0.8 1.56 33 35 2080 2160 2.00 1.56 36 37 2620 2740
44 0.40 2.20 35 37 1900 1980 4x0.8 1.56 36 37 2300 2380 2.00 1.56 38 40 2900 3020
52 0.40 2.20 37 38 2190 2280 4x0.8 1.56 37 39 2600 2700 2.00 1.72 40 42 3260 3400
61 0.40 2.20 39 41 2520 2620 4x0.8 1.56 40 41 2950 3050 2.00 1.72 42 44 3640 3810
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
Conductor : Solid / Stranded Annealed Bare Copper as per Class-2 of IS: 8130; Options : Tinned
Insulation Material : PVC Type-A OR HR PVC Type-C as per IS: 5831; Nominal Insulation Thickness : 0.90 mm
Core Identication : Upto 5 cores : By colour coding & Above 5 cores : By colour coding / Number printing on
cores as per IS : 1554 Part-1
Inner Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Armouring : Single Layer of Aluminium Round Wire / Flat Strip
Outer Sheath : PVC Type ST-1 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement
Electrical Parameters
Normal Current Rating
Max. Reactance Short Circuit Current Rating for 1 Second
No. Approx. Conductor Capacitance For General Purpose For Heat Resisting
Conductor of Cable Duration
of A.C.Resistance of Cable Insulation Insulation
D.C.Resistance at 50 Hz
Cores (Approx.) For General Purpose For Heat Resisting
at 20 C at 70 C at 85 C (Approx.) Ground Duct Air Ground Duct Air
Insulation Insulation
No's Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
2 7.41 8.89 9.34 0.107 0.22 32 27 27 38 32 32 0.288 0.260
3 7.41 8.89 9.34 0.107 0.22 27 24 24 30 28 28 0.288 0.260
4 7.41 8.89 9.34 0.107 0.22 27 24 24 30 28 28 0.288 0.260
5 7.41 8.89 9.34 0.107 0.22 27 24 24 30 28 28 0.288 0.260
6 7.41 8.89 9.34 0.107 0.22 21 18 18 24 21 21 0.288 0.260
7 7.41 8.89 9.34 0.107 0.22 20 17 17 22 20 20 0.288 0.260
10 7.41 8.89 9.34 0.107 0.22 18 15 15 20 16 16 0.288 0.260
12 7.41 8.89 9.34 0.107 0.22 17 14 14 19 16 16 0.288 0.260
14 7.41 8.89 9.34 0.107 0.22 16 13 13 18 15 15 0.288 0.260
16 7.41 8.89 9.34 0.107 0.22 15 13 13 17 15 15 0.288 0.260
19 7.41 8.89 9.34 0.107 0.22 14 12 12 16 14 14 0.288 0.260
24 7.41 8.89 9.34 0.107 0.22 13 11 11 14 13 13 0.288 0.260
27 7.41 8.89 9.34 0.107 0.220 12 10 10 13 12 12 0.288 0.260
30 7.41 8.89 9.34 0.107 0.22 12 10 10 13 12 12 0.288 0.260
37 7.41 8.89 9.34 0.107 0.22 11 9 9 12 10 10 0.288 0.260
40 7.41 8.89 9.34 0.107 0.22 11 9 9 12 10 10 0.288 0.260
44 7.41 8.89 9.34 0.107 0.22 10 9 9 11 10 10 0.288 0.260
52 7.41 8.89 9.34 0.107 0.22 9 8 8 10 10 10 0.288 0.260
61 7.41 8.89 9.34 0.107 0.22 8 8 8 9 9 9 0.288 0.260
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no.52 - 54

23
LT/HT Power & Control Cables

Table - 13
TECHNICAL DETAILS FOR HAVELLS 1.1 KV
SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, UN-ARMOURED CABLES
Ref Specication : IS 7098 Part-1
Physical Parameters Cable Code : A2XY/2XY
Minimum No. of Strand in
Size Approx. Weight of Cable
Conductor Nominal Insulation Nominal Outer
(Cross Sectional Approx. Overall Dia of Cable
Thickness Sheath Thickness With Al'm Cond. With Cu Cond.
Area) Aluminium Copper
A2XY 2XY
Sqmm No's No's mm mm mm Kg/Km Kg/Km
4 1/3 1/3 0.70 1.80 7 70 90
6 1/3 1/3 0.70 1.80 8 80 110
10 1/7 6 0.70 1.80 9 90 160
16 6 6 0.70 1.80 10 130 250
25 6 6 0.90 1.80 11 150 350
35 6 6 0.90 1.80 12 200 400
50 6 6 1.00 1.80 14 250 550
70 12 12 1.10 1.80 16 350 750
95 15 15 1.10 1.80 18 450 1000
120 15 18 1.20 1.80 19 500 1250
150 15 18 1.40 2.00 21 650 1500
185 30 30 1.60 2.00 24 800 1850
240 30 34 1.70 2.00 26 950 2400
300 30 34 1.80 2.00 29 1150 2950
400 53 53 2.00 2.20 33 1500 3750
500 53 53 2.20 2.20 36 1850 4750
630 53 53 2.40 2.20 40 2350 6100
800 53 53 2.60 2.40 44 2900 7750
1000 53 53 2.80 2.60 48 3600 9650
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.
Cross-sectional view
1 Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Circular
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm and above - Stranded Compacted Circular
2
Insulation Material : XLPE (Cross linked polyethylene); Colour : Natural
3
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Max. Conductor Approx. Conductor Short Circuit Current
Size Reactance Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C Rating for 1 Second
(Cross of Cable Capacitance of
Sectional at 50 Hz Cable (Approx.) For Aluminium Conductor For Copper Conductor Duration
Aluminium Copper Aluminium Copper
Area) (Approx.) Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
4 7.41 4.61 9.48 5.90 0.136 0.29 48 47 45 0.376 0.572
6 4.61 3.08 5.90 3.94 0.128 0.34 48 45 45 60 59 57 0.564 0.858
10 3.08 1.83 3.94 2.34 0.118 0.42 62 62 61 80 78 77 0.940 1.43
16 1.91 1.15 2.44 1.47 0.108 0.50 81 80 83 104 102 106 1.50 2.28
25 1.20 0.727 1.54 0.931 0.102 0.52 99 90 115 130 115 145 2.35 3.57
35 0.868 0.524 1.11 0.671 0.097 0.60 117 110 135 155 140 175 3.29 5.00
50 0.641 0.387 0.820 0.495 0.092 0.63 138 125 170 185 165 215 4.70 7.15
70 0.443 0.268 0.567 0.343 0.088 0.68 168 155 210 225 200 270 6.58 10.01
95 0.320 0.193 0.411 0.248 0.085 0.79 204 185 255 265 235 330 8.93 13.59
120 0.253 0.153 0.325 0.197 0.082 0.79 230 210 300 300 265 380 11.28 17.16
150 0.206 0.1240 0.265 0.159 0.082 0.79 265 230 342 335 300 430 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.082 0.79 295 260 385 380 335 495 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.079 0.84 340 300 450 435 385 590 22.56 34.32
300 0.100 0.0601 0.130 0.0778 0.078 0.86 390 335 519 490 430 670 28.20 42.90
400 0.0778 0.0470 0.1023 0.0618 0.077 0.88 450 380 605 550 480 780 37.60 57.20
500 0.0605 0.0366 0.0808 0.0489 0.076 0.90 500 430 700 610 530 900 47.00 71.50
630 0.0469 0.0283 0.0648 0.0391 0.075 0.94 555 485 809 680 590 1020 59.22 90.09
800 0.0367 0.0221 0.0530 0.0319 0.075 0.97 625 530 935 740 630 1140 75.20 114.40
1000 0.0291 0.0176 0.0444 0.0268 0.068 1.01 690 570 1065 780 660 1250 94.00 143.00
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

24
LT/HT Power & Control Cables

Table - 14
TECHNICAL DETAILS FOR HAVELLS 1.1 KV
TWO CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, UN-ARMOURED CABLES
Ref Specication : IS 7098 Part-1
Physical Parameters Cable Code : A2XY/2XY
Minimum No. of Strand in
Size Nominal Minimum Inner Approx. Weight of Cable
Conductor Nominal Outer Approx. Overall
(Cross Sectional Insulation Sheath
Sheath Thickness Dia of Cable With Al'm Cond. With Cu Cond.
Area) Aluminium Copper Thickness Thickness
A2XY 2XY
Sqmm No's No's mm mm mm mm Kg/Km Kg/Km
4 1/3 1/3 0.70 0.30 1.80 12 180 240
6 1/3 1/3 0.70 0.30 1.80 13 220 300
10 1/7 6 0.70 0.30 1.80 15 280 420
16 6 6 0.70 0.30 1.80 14 250 450
25 6 6 0.90 0.30 2.00 18 400 700
35 6 6 0.90 0.30 2.00 19 450 900
50 6 6 1.00 0.30 2.00 21 600 1150
70 12 12 1.10 0.30 2.00 24 750 1550
95 15 15 1.10 0.40 2.20 27 950 2100
120 15 18 1.20 0.40 2.20 29 1150 2550
150 15 18 1.40 0.40 2.20 31 1350 3100
185 30 30 1.60 0.50 2.40 35 1700 3850
240 30 34 1.70 0.50 2.60 40 2150 5000
300 30 34 1.80 0.60 2.80 43 2650 6200
400 53 53 2.00 0.60 3.00 48 3300 7850
500 53 53 2.20 0.70 3.40 54 4200 10000
630 53 53 2.40 0.70 3.80 59 5200 12750
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
1 Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
2 16 Sq.mm and above - Stranded Compacted Shaped
3 Insulation Material : XLPE (Cross linked polyethylene); Colour : Red & Black
4
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Max. Conductor Approx. Conductor Short Circuit Current
Size Reactance Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C Rating for 1 Second
(Cross of Cable Capacitance of
Sectional at 50 Hz Cable (Approx.) For Aluminium Conductor For Copper Conductor Duration
Aluminium Copper Aluminium Copper
Area) (Approx.) Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
4 7.41 4.61 9.48 5.90 0.098 0.11 34 28 30 44 37 39 0.376 0.572
6 4.61 3.08 5.90 3.94 0.090 0.13 43 37 40 55 47 50 0.564 0.858
10 3.08 1.83 3.94 2.34 0.084 0.16 57 48 53 74 61 67 0.940 1.43
16 1.91 1.15 2.44 1.47 0.080 0.18 78 61 70 94 78 85 1.50 2.29
25 1.20 0.727 1.54 0.931 0.080 0.20 95 80 99 120 100 125 2.35 3.58
35 0.868 0.524 1.11 0.671 0.080 0.23 116 94 117 145 120 155 3.29 5.01
50 0.641 0.387 0.820 0.495 0.078 0.24 140 110 140 170 145 190 4.70 7.15
70 0.443 0.268 0.567 0.343 0.077 0.26 170 140 176 210 175 235 6.58 10.01
95 0.320 0.193 0.411 0.248 0.074 0.29 200 165 221 250 210 290 8.93 13.59
120 0.253 0.153 0.325 0.197 0.072 0.29 225 185 258 285 240 330 11.28 17.16
150 0.206 0.1240 0.265 0.159 0.072 0.29 255 210 294 315 270 375 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.072 0.29 285 235 339 355 300 435 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.072 0.31 325 270 402 410 350 510 22.56 34.32
300 0.100 0.0601 0.130 0.0778 0.071 0.33 370 305 461 460 390 590 28.20 42.90
400 0.0778 0.0470 0.1023 0.0618 0.070 0.33 435 350 542 520 440 670 37.60 57.20
500 0.0605 0.0366 0.0808 0.0489 0.070 0.34 481 405 624 580 480 750 47.00 71.50
630 0.0469 0.0283 0.0648 0.0391 0.069 0.36 537 470 723 680 575 875 59.22 90.09
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

25
LT/HT Power & Control Cables

Table - 15
TECHNICAL DETAILS FOR HAVELLS 1.1 KV
THREE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, UN-ARMOURED CABLES
Ref Specication : IS 7098 Part-1
Physical Parameters Cable Code : A2XY/2XY
Minimum No. of Strand in
Size Nominal Minimum Inner Approx. Weight of Cable
Conductor Nominal Outer Approx. Overall
(Cross Sectional Insulation Sheath
Sheath Thickness Dia of Cable With Al'm Cond. With Cu Cond.
Area) Aluminium Copper Thickness Thickness
A2XY 2XY
Sqmm No's No's mm mm mm mm Kg/Km Kg/Km
4 1/3 1/3 0.70 0.30 1.80 13 200 280
6 1/3 1/3 0.70 0.30 1.80 14 250 360
10 1/7 6 0.70 0.30 1.80 16 310 510
16 6 6 0.70 0.30 1.80 17 350 650
25 6 6 0.90 0.30 2.00 20 500 950
35 6 6 0.90 0.30 2.00 22 600 1250
50 6 6 1.00 0.30 2.00 24 800 1600
70 12 12 1.10 0.40 2.20 28 1050 2250
95 15 15 1.10 0.40 2.20 31 1300 3000
120 15 18 1.20 0.40 2.20 34 1600 3700
150 15 18 1.40 0.50 2.40 38 1950 4550.70
185 30 30 1.60 0.50 2.60 42 2450 5650
240 30 34 1.70 0.60 2.80 47 3100 7350
300 30 34 1.80 0.60 3.00 52 3800 9100
400 53 53 2.00 0.70 3.20 58 4750 11550
500 53 53 2.20 0.70 3.60 65 6000 14750
630 53 53 2.40 0.70 3.80 73 7500 18800
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
1
Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
2
Insulation Material : XLPE (Cross linked polyethylene); Colour : Red, Yellow & Blue
3 Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
4 Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Max. Conductor Approx. Conductor Short Circuit Current
Size Reactance Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C Rating for 1 Second
(Cross of Cable Capacitance of
Sectional at 50 Hz Cable (Approx.) For Aluminium Conductor For Copper Conductor Duration
Aluminium Copper Aluminium Copper
Area) (Approx.) Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
4 7.41 4.61 9.48 5.90 0.098 0.11 34 28 30 44 37 39 0.376 0.572
6 4.61 3.08 5.90 3.94 0.090 0.13 43 37 40 55 47 50 0.564 0.858
10 3.08 1.83 3.94 2.34 0.084 0.16 57 48 53 74 61 67 0.940 1.43
16 1.91 1.15 2.44 1.47 0.080 0.18 78 61 70 94 78 85 1.50 2.29
25 1.20 0.727 1.54 0.931 0.080 0.20 95 80 99 120 100 125 2.35 3.58
35 0.868 0.524 1.11 0.671 0.080 0.23 116 94 117 145 120 155 3.29 5.01
50 0.641 0.387 0.820 0.495 0.078 0.24 140 110 140 170 145 190 4.70 7.15
70 0.443 0.268 0.567 0.343 0.077 0.26 170 140 176 210 175 235 6.58 10.01
95 0.320 0.193 0.411 0.248 0.074 0.29 200 165 221 250 210 290 8.93 13.59
120 0.253 0.153 0.325 0.197 0.072 0.29 225 185 258 285 240 330 11.28 17.16
150 0.206 0.1240 0.265 0.159 0.072 0.29 255 210 294 315 270 375 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.072 0.29 285 235 339 355 300 435 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.072 0.31 325 270 402 410 350 510 22.56 34.32
300 0.100 0.0601 0.130 0.0778 0.071 0.33 370 305 461 460 390 590 28.20 42.90
400 0.0778 0.0470 0.1023 0.0618 0.070 0.33 435 350 542 520 440 670 37.60 57.20
500 0.0605 0.0366 0.0808 0.0489 0.070 0.34 481 405 624 580 480 750 47.00 71.50
630 0.0469 0.0283 0.0648 0.0391 0.069 0.36 537 470 723 680 575 875 59.22 90.09
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

26
LT/HT Power & Control Cables

Table - 16
TECHNICAL DETAILS FOR HAVELLS 1.1 KV, THREE & HALF CORE
ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, UN-ARMOURED CABLES
Ref Specication : IS 7098 Part-1
Physical Parameters Cable Code : A2XY/2XY
Minimum No. of Strand in
Size Nominal Minimum Inner Approx. Weight of Cable
Conductor Nominal Outer Approx. Overall
(Cross Sectional Insulation Sheath
Sheath Thickness Dia of Cable With Al'm Cond. With Cu Cond.
Area) Aluminium Copper Thickness Thickness
A2XY 2XY
Sqmm No's No's mm mm mm mm Kg/Km Kg/Km
3X25 +16 6/6 6/6 0.90/0.70 0.30 2.00 21 600 1150
3X35 +16 6/6 6/6 0.90/0.70 0.30 2.00 24 700 1400
3X 50+25 6/6 6/6 1.00/0.90 0.30 2.00 26 900 1850
3X70+35 12/6 12/6 1.10/0.90 0.40 2.20 30 1200 2600
3X95 +50 15/6 15/6 1.10/1.00 0.40 2.20 34 1500 3450
3X120+70 15/12 18/12 1.20/1.10 0.40 2.20 37 1800 4350
3X150+70 15/12 18/12 1.40/1.10 0.50 2.40 41 2250 5250
3X 185+95 30/15 30/15 1.60/1.10 0.50 2.60 46 2800 6600
3X240+120 30/15 34/18 1.70/1.20 0.60 2.80 50 3550 8500
3X300+150 30/15 34/18 1.80/1.40 0.60 3.00 55 4300 10500
3X400+185 53/30 53/30 2.00/1.60 0.70 3.40 62 5450 13350
3X500+240 53/30 53/34 2.20/1.70 0.70 3.60 72 6900 17050
3X630+300 53/30 53/34 2.40/1.80 0.70 4.00 80 8700 21750
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view

1 Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130


Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
2
Insulation Material : XLPE (Cross linked polyethylene); Colour : Red, Yellow, Blue & Black
3 Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
4
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Max. Conductor Approx. Conductor Short Circuit Current
Reactance Normal Current Rating
Size D.C.Resistance at 20 C A.C.Resistance at 90 C Capacitance Rating for 1 Second
of Cable
(Cross Sectional of Cable For Aluminium Conductor For Copper Conductor Duration
at 50 Hz
Area) Aluminium Copper Aluminium Copper (Approx.)
(Approx.) Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
3X25+16 1.20 0.727 1.54 0.931 0.080 0.20 95 80 99 120 100 125 2.35 3.58
3X35+16 0.868 0.524 1.11 0.671 0.080 0.23 116 94 117 145 120 155 3.29 5.01
3X50+25 0.641 0.387 0.820 0.495 0.078 0.24 140 110 140 170 145 190 4.70 7.15
3X70+35 0.443 0.268 0.567 0.343 0.077 0.26 170 140 176 210 175 235 6.58 10.01
3X95+50 0.320 0.193 0.411 0.248 0.074 0.29 200 165 221 250 210 290 8.93 13.59
3X120+70 0.253 0.153 0.325 0.197 0.072 0.29 225 185 258 285 240 330 11.28 17.16
3X150+70 0.206 0.1240 0.265 0.159 0.072 0.29 255 210 294 315 270 375 14.10 21.45
3X185+95 0.164 0.0991 0.211 0.127 0.072 0.29 285 235 339 355 300 435 17.39 26.46
3X240+120 0.125 0.0754 0.162 0.0976 0.072 0.31 325 270 402 410 350 510 22.56 34.32
3X300+150 0.100 0.0601 0.130 0.0778 0.071 0.33 370 305 461 460 390 590 28.20 42.90
3X400+185 0.0778 0.0470 0.1023 0.0618 0.070 0.33 435 350 542 520 440 670 37.60 57.20
3X500+240 0.0605 0.0366 0.0808 0.0489 0.070 0.34 481 405 624 580 480 750 47.00 71.50
3X630+300 0.0469 0.0283 0.0648 0.0391 0.069 0.36 537 470 723 680 575 875 59.22 90.09
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

27
LT/HT Power & Control Cables

Table - 17
TECHNICAL DETAILS FOR HAVELLS 1.1 KV
FOUR CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, UN-ARMOURED CABLES
Ref Specication : IS 7098 Part-1
Physical Parameters Cable Code : A2XY/2XY
Minimum No. of Strand in
Size Nominal Minimum Inner Approx. Weight of Cable
Conductor Nominal Outer Approx. Overall
(Cross Sectional Insulation Sheath
Sheath Thickness Dia of Cable With Al'm Cond. With Cu Cond.
Area) Aluminium Copper Thickness Thickness
A2XY 2XY
Sqmm No's No's mm mm mm mm Kg/Km Kg/Km
4 1/3 1/3 0.70 0.30 1.80 14 230 340
6 1/3 1/3 0.70 0.30 1.80 15 290 430
10 1/7 6 0.70 0.30 1.80 17 360 630
16 6 6 0.70 0.30 1.80 19 450 800
25 6 6 0.90 0.30 2.00 22 600 1200
35 6 6 0.90 0.30 2.00 24 750 1600
50 6 6 1.00 0.30 2.00 27 950 2000
70 12 12 1.10 0.40 2.20 31 1300 2900
95 15 15 1.10 0.40 2.20 35 1700 3900
120 15 18 1.20 0.50 2.40 39 2100 4900
150 15 18 1.40 0.50 2.60 43 2550 6000
185 30 30 1.60 0.50 2.80 48 3150 7450
240 30 34 1.70 0.60 3.00 54 4000 9700
300 30 34 1.80 0.70 3.20 61 4950 12050
400 53 53 2.00 0.70 3.60 68 6250 15350
500 53 53 2.20 0.70 3.80 75 7800 19450
630 53 53 2.40 0.70 4.00 84 9800 24850
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.
Cross-sectional view
Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : XLPE (Cross linked polyethylene); Colour : Red, Yellow & Blue
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Max. Conductor Approx. Conductor Short Circuit Current
Size Reactance Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C Rating for 1 Second
(Cross of Cable Capacitance of
Sectional at 50 Hz Cable (Approx.) For Aluminium Conductor For Copper Conductor Duration
Aluminium Copper Aluminium Copper
Area) (Approx.) Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
4 7.41 4.61 9.48 5.90 0.098 0.11 34 28 30 44 37 39 0.376 0.572
6 4.61 3.08 5.90 3.94 0.090 0.13 43 37 40 55 47 50 0.564 0.858
10 3.08 1.83 3.94 2.34 0.084 0.16 57 48 53 74 61 67 0.940 1.43
16 1.91 1.15 2.44 1.47 0.080 0.18 78 61 70 94 78 85 1.50 2.29
25 1.20 0.727 1.54 0.931 0.080 0.20 95 80 99 120 100 125 2.35 3.58
35 0.868 0.524 1.11 0.671 0.080 0.23 116 94 117 145 120 155 3.29 5.01
50 0.641 0.387 0.820 0.495 0.078 0.24 140 110 140 170 145 190 4.70 7.15
70 0.443 0.268 0.567 0.343 0.077 0.26 170 140 176 210 175 235 6.58 10.01
95 0.320 0.193 0.411 0.248 0.074 0.29 200 165 221 250 210 290 8.93 13.59
120 0.253 0.153 0.325 0.197 0.072 0.29 225 185 258 285 240 330 11.28 17.16
150 0.206 0.1240 0.265 0.159 0.072 0.29 255 210 294 315 270 375 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.072 0.29 285 235 339 355 300 435 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.072 0.31 325 270 402 410 350 510 22.56 34.32
300 0.100 0.0601 0.130 0.0778 0.071 0.33 370 305 461 460 390 590 28.20 42.90
400 0.0778 0.0470 0.1023 0.0618 0.070 0.33 435 350 542 520 440 670 37.60 57.20
500 0.0605 0.0366 0.0808 0.0489 0.070 0.34 481 405 624 580 480 750 47.00 71.50
630 0.0469 0.0283 0.0648 0.0391 0.069 0.36 537 470 723 680 575 875 59.22 90.09
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

28
LT/HT Power & Control Cables

Table - 18
TECHNICAL DETAILS FOR HAVELLS 1.1 KV
SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-1
Physical Parameters Cable Code : A2XFaY/2XFaY, A2XWaY/2XWaY
Flat Strip Armoured (A2XFaY/2XFaY) Round Wire Armoured (A2XWaY/2XWaY)
Size Nominal Approx. Weight of Cable Approx. Weight of Cable
Minimum No. of Nominal Minimum Nominal Minimum
Approx. With Alm With Cu Approx. With Al'm With Cu
(Cross Strand in Conductor Insulation Armour Outer Dia of Outer
Overall Dia Cond. Cond. Overall Dia Cond. Cond.
Sectional Thickness Strip Sheath Armor Sheath
of Cable of Cable
Area) Aluminium Copper Dimension Thickness A2XFaY 2XFaY Wire Thickness A2XWaY 2XWaY
Sqmm No's No's mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
4 1/3 1/3 1.00 N/A N/A N/A N/A N/A 1.40 1.24 10 120 150
6 1/3 1/3 1.00 N/A N/A N/A N/A N/A 1.40 1.24 11 130 170
10 1/7 6 1.00 N/A N/A N/A N/A N/A 1.40 1.24 12 150 220
16 6 6 1.00 N/A N/A N/A N/A N/A 1.40 1.24 12 200 300
25 6 6 1.20 N/A N/A N/A N/A N/A 1.40 1.24 14 250 400
35 6 6 1.20 N/A N/A N/A N/A N/A 1.40 1.24 15 300 500
50 6 6 1.3 N/A N/A N/A N/A N/A 1.40 1.24 16 360 650
70 12 12 1.40 N/A N/A N/A N/A N/A 1.40 1.24 18 450 850
95 15 15 1.40 4 X 0.80 1.40 19 500 1100 1.60 1.40 21 600 1150
120 15 18 1.50 4 X 0.80 1.40 21 600 1300 1.60 1.40 22 700 1400
150 15 18 1.70 4 X 0.80 1.40 23 700 1600 1.60 1.40 24 800 1650
185 30 30 1.90 4 X 0.80 1.40 25 900 1950 1.60 1.40 26 950 2050
240 30 34 2.00 4 X 0.80 1.40 27 1050 2500 1.60 1.40 29 1150 2600
300 30 34 2.10 4 X 0.80 1.56 30 1300 3100 1.60 1.56 32 1400 3200
400 53 53 2.40 4 X 0.80 1.56 34 1650 3900 2.00 1.56 36 1850 4100
500 53 53 2.60 4 X 0.80 1.56 37 2000 4900 2.00 1.56 40 2200 5100
630 53 53 2.80 4 X 0.80 1.72 42 2520 6300 2.00 1.72 44 2750 6500
800 53 53 3.10 4 X 0.80 1.72 46 3150 7950 2.00 1.88 49 3450 8250
1000 53 53 3.30 4 X 0.80 1.88 50 3850 9850 2.50 2.04 54 4300 10300
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Circular
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm and above - Stranded Compacted Circular
Insulation Material : XLPE (Cross linked polyethylene); Colour : Natural
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Armouring : Single Layer of Aluminium Round Wire / Flat Strip
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement
Electrical Parameters
Max. Conductor Approx. Conductor Short Circuit Current
Size Reactance Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C Rating for 1 Second
(Cross of Cable Capacitance of
Sectional at 50 Hz Cable (Approx.) For Aluminium Conductor For Copper Conductor Duration
Aluminium Copper Aluminium Copper
Area) (Approx.) Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
4 7.41 4.61 9.48 5.90 0.152 0.22 48 47 45 0.376 0.572
6 4.61 3.08 5.90 3.94 0.144 0.26 45 45 40 60 59 57 0.56 0.858
10 3.08 1.83 3.94 2.34 0.133 0.31 59 62 53 80 78 77 0.94 1.43
16 1.91 1.15 2.44 1.47 0.122 0.40 76 80 73 104 102 106 1.50 2.29
25 1.20 0.727 1.54 0.931 0.116 0.40 99 90 115 130 115 145 2.35 3.58
35 0.868 0.524 1.11 0.671 0.110 0.47 117 110 140 155 140 175 3.29 5.01
50 0.641 0.387 0.820 0.495 0.103 0.50 138 125 170 185 165 215 4.70 7.15
70 0.443 0.268 0.567 0.343 0.099 0.55 168 155 210 225 200 270 6.58 10.01
95 0.320 0.193 0.411 0.248 0.097 0.64 204 185 255 265 235 330 8.93 13.59
120 0.253 0.153 0.325 0.197 0.093 0.67 230 210 300 300 265 380 11.28 17.16
150 0.206 0.1240 0.265 0.159 0.091 0.67 265 230 342 335 300 430 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.090 0.67 295 260 385 380 335 495 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.086 0.72 340 300 450 435 385 590 22.56 34.32
300 0.100 0.0601 0.130 0.0778 0.085 0.75 390 335 519 490 430 670 28.20 42.90
400 0.0778 0.0470 0.1023 0.0618 0.085 0.75 450 380 605 550 480 780 37.60 57.20
500 0.0605 0.0366 0.0808 0.0489 0.083 0.77 500 430 700 610 530 900 47.00 71.50
630 0.0469 0.0283 0.0648 0.0391 0.082 0.81 555 485 809 680 590 1020 59.22 90.09
800 0.0367 0.0221 0.0530 0.0319 0.081 0.88 625 530 935 740 630 1140 75.20 114.40
1000 0.0291 0.0176 0.0444 0.0268 0.081 0.88 690 570 1065 780 660 1250 94.00 143.00
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

29
LT/HT Power & Control Cables

Table - 19
TECHNICAL DETAILS FOR HAVELLS 1.1 KV
TWO CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-1
Physical Parameters Cable Code : A2XFY/2XFY, A2XWY/2XWY
Flat Strip Armoured (A2XFY/2XFY) Round Wire Armoured (A2XWY/2XWY)
Size Nominal Minimum Nominal Minimum Approx. Approx. Weight of Cable Approx. Weight of Cable
Minimum No. of Nominal Minimum Approx.
(Cross Strand in Conductor Insulation Inner Armour Outer Overall With Al'm With Cu Dia of Outer Overall With Al'm With Cu
Sectional Thickness Sheath Strip Sheath Dia of Cond. Cond. Armor Sheath Dia of Cond. Cond.
Area) Aluminium Copper Thickness Dimension Thickness Cable A2XFY 2XFY Wire Thickness Cable A2XWY 2XWY
Sqmm No's No's mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
4 1/3 1/3 0.70 0.30 N/A N/A N/A N/A N/A 1.40 1.24 14 370 470
6 1/3 1/3 0.70 0.30 N/A N/A N/A N/A N/A 1.40 1.24 15 460 550
10 1/7 6 0.70 0.30 N/A N/A N/A N/A N/A 1.40 1.24 17 530 700
16 6 6 0.70 0.30 N/A N/A N/A N/A N/A 1.40 1.40 17 550 750
25 6 6 0.90 0.30 4 X 0.80 1.40 18 550 850.0 1.60 1.40 20 750 1050
35 6 6 0.90 0.30 4 X 0.80 1.40 20 650 1050.0 1.60 1.40 21 850 1250
50 6 6 1.00 0.30 4 X 0.80 1.40 22 750 1350.0 1.60 1.40 23 1000 1550
70 12 12 1.10 0.30 4 X 0.80 1.56 25 1000 1800.0 1.60 1.56 26 1250 2050
95 15 15 1.10 0.40 4 X 0.80 1.56 27 1250 2350.0 2.00 1.56 30 1700 2800
120 15 18 1.20 0.40 4 X 0.80 1.56 30 1450 2850.0 2.00 1.56 32 1950 3350
150 15 18 1.40 0.40 4 X 0.80 1.72 32 1700 3450.0 2.00 1.72 35 2250 4000
185 30 30 1.60 0.50 4 X 0.80 1.72 35 2050 4200.0 2.00 1.88 38 2700 4850
240 30 34 1.70 0.50 4 X 0.80 1.88 40 2550 5400.0 2.50 2.04 44 3550 6350
300 30 34 1.80 0.60 4 X 0.80 2.04 43 3000 6550.0 2.50 2.20 47 4100 7650
400 53 53 2.00 0.60 4 X 0.80 2.36 49 4000 8300.0 2.50 2.36 52 4950 9500
500 53 53 2.20 0.70 4 X 0.80 2.52 54 4650 10450.0 3.15 2.68 59 6500 12300
630 53 53 2.40 0.70 4 X 0.80 2.68 60 5700 13200.0 3.15 2.84 64 7800 15350
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : XLPE (Cross linked polyethylene); Colour : Red & Black
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Armouring : Single Layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement
Electrical Parameters
Max. Conductor Approx. Conductor Short Circuit Current
Size Reactance Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C Rating for 1 Second
(Cross of Cable Capacitance of
Sectional at 50 Hz Cable (Approx.) For Aluminium Conductor For Copper Conductor Duration
Aluminium Copper Aluminium Copper
Area) (Approx.) Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
4 7.41 4.61 9.48 5.90 0.098 0.11 34 28 30 44 37 39 0.376 0.572
6 4.61 3.08 5.90 3.94 0.090 0.13 43 37 40 55 47 50 0.564 0.858
10 3.08 1.83 3.94 2.34 0.084 0.16 57 48 53 74 61 67 0.940 1.43
16 1.91 1.15 2.44 1.47 0.080 0.18 78 61 70 94 78 85 1.50 2.29
25 1.20 0.727 1.54 0.931 0.080 0.20 95 80 99 120 100 125 2.35 3.58
35 0.868 0.524 1.11 0.671 0.080 0.23 116 94 117 145 120 155 3.29 5.01
50 0.641 0.387 0.820 0.495 0.078 0.24 140 110 140 170 145 190 4.70 7.15
70 0.443 0.268 0.567 0.343 0.077 0.26 170 140 176 210 175 235 6.58 10.1
95 0.320 0.193 0.411 0.248 0.074 0.29 200 165 221 250 210 290 8.93 13.59
120 0.253 0.153 0.325 0.197 0.072 0.29 225 185 258 285 240 330 11.28 17.16
150 0.206 0.1240 0.265 0.159 0.072 0.29 255 210 294 315 270 375 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.072 0.29 285 235 339 355 300 435 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.072 0.31 325 270 402 410 350 510 22.56 34.32
300 0.100 0.0601 0.130 0.0778 0.071 0.33 370 305 461 460 390 590 28.20 42.90
400 0.0778 0.0470 0.1023 0.0618 0.070 0.33 435 350 542 520 440 670 37.60 57.20
500 0.0605 0.0366 0.0808 0.0489 0.070 0.34 481 405 624 580 480 750 47.00 71.50
630 0.0469 0.0283 0.0648 0.0391 0.069 0.36 537 470 723 680 575 875 59.22 90.09
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

30
LT/HT Power & Control Cables

Table - 20
TECHNICAL DETAILS FOR HAVELLS 1.1 KV
THREE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-1
Physical Parameters Cable Code : A2XFY/2XFY, A2XWY/2XWY
Flat Strip Armoured (A2XFY/2XFY) Round Wire Armoured (A2XWY/2XWY)
Size Nominal Minimum Nominal Minimum Approx. Approx. Weight of Cable Approx. Weight of Cable
Minimum No. of Nominal Minimum Approx.
(Cross Strand in Conductor Insulation Inner Armour Outer Overall With Al'm With Cu Dia of Outer Overall With Al'm With Cu
Sectional Thickness Sheath Strip Sheath Dia of Cond. Cond. Armor Sheath Dia of Cond. Cond.
Area) Aluminium Copper Thickness Dimension Thickness Cable A2XFY 2XFY Wire Thickness Cable A2XWY 2XWY
Sqmm No's No's mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
4 1/3 1/3 0.70 0.30 N/A N/A N/A N/A N/A 1.40 1.24 15 400 490
6 1/3 1/3 0.70 0.30 N/A N/A N/A N/A N/A 1.40 1.24 16 460 580
10 1/7 6 0.70 0.30 N/A N/A N/A N/A N/A 1.40 1.24 17 540 750
16 6 6 0.70 0.30 4 X 0.80 1.24 18 550 850.0 1.60 1.40 20 700 1000
25 6 6 0.90 0.30 4 X 0.80 1.40 20 700 1150.0 1.60 1.40 22 900 1350
35 6 6 0.90 0.30 4 X 0.80 1.40 22 850 1450.0 1.60 1.40 24 1050 1700
50 6 6 1.00 0.30 4 X 0.80 1.40 25 1000 1850.0 1.60 1.56 27 1300 2100
70 12 12 1.10 0.40 4 X 0.80 1.56 29 1350 2550.0 2.00 1.56 31 1800 3000
95 15 15 1.10 0.40 4 X 0.80 1.56 31 1600 3300.0 2.00 1.56 34 2150 3800
120 15 18 1.20 0.40 4 X 0.80 1.56 34 1900 4000.0 2.00 1.72 37 2550 4650
150 15 18 1.40 0.50 4 X 0.80 1.72 38 2350 4950.0 2.00 1.88 41 3000 5600
185 30 30 1.60 0.50 4 X 0.80 1.88 42 2850 6050.0 2.50 2.04 46 3950 7150
240 30 34 1.70 0.60 4 X 0.80 2.04 47 3500 7750.0 2.50 2.20 51 4800 9000
300 30 34 1.80 0.60 4 X 0.80 2.20 52 4250 9550.0 2.50 2.36 56 5600 10900
400 53 53 2.00 0.70 4 X 0.80 2.52 59 5350 12250.0 3.15 2.68 64 7450 14200
500 53 53 2.20 0.70 4 X 0.80 2.68 65 6550 15300.0 3.15 2.84 70 8900 17600
630 53 53 2.40 0.70 4 X 0.80 2.84 73 8150 19450.0 4.00 3.00 79 11800 23100
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : XLPE (Cross linked polyethylene); Colour : Red,Yellow & Blue
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Armouring : Single Layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Max. Conductor Approx. Conductor Short Circuit Current
Size Reactance Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C Rating for 1 Second
(Cross of Cable Capacitance of
Sectional at 50 Hz Cable (Approx.) For Aluminium Conductor For Copper Conductor Duration
Aluminium Copper Aluminium Copper
Area) (Approx.) Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
4 7.41 4.61 9.48 5.90 0.098 0.11 34 28 30 44 37 39 0.376 0.572
6 4.61 3.08 5.90 3.94 0.090 0.13 43 37 40 55 47 50 0.564 0.858
10 3.08 1.83 3.94 2.34 0.084 0.16 57 48 53 74 61 67 0.940 1.43
16 1.91 1.15 2.44 1.47 0.080 0.18 78 61 70 94 78 85 1.50 2.29
25 1.20 0.727 1.54 0.931 0.080 0.20 95 80 99 120 100 125 2.35 3.58
35 0.868 0.524 1.11 0.671 0.080 0.23 116 94 117 145 120 155 3.29 5.01
50 0.641 0.387 0.820 0.495 0.078 0.24 140 110 140 170 145 190 4.70 7.15
70 0.443 0.268 0.567 0.343 0.077 0.26 170 140 176 210 175 235 6.58 10.01
95 0.320 0.193 0.411 0.248 0.074 0.29 200 165 221 250 210 290 8.93 13.59
120 0.253 0.153 0.325 0.197 0.072 0.29 225 185 258 285 240 330 11.28 17.16
150 0.206 0.1240 0.265 0.159 0.072 0.29 255 210 294 315 270 375 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.072 0.29 285 235 339 355 300 435 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.072 0.31 325 270 402 410 350 510 22.56 34.32
300 0.100 0.0601 0.130 0.0778 0.071 0.33 370 305 460 460 390 590 28.20 42.90
400 0.0778 0.0470 0.1023 0.0618 0.070 0.33 435 350 542 520 440 670 37.60 57.20
500 0.0605 0.0366 0.0808 0.0489 0.070 0.34 481 405 624 580 480 750 47.00 71.50
630 0.0469 0.0283 0.0648 0.0391 0.069 0.36 537 470 723 680 575 875 59.22 90.09
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

31
LT/HT Power & Control Cables

Table - 21
TECHNICAL DETAILS FOR HAVELLS 1.1 KV, THREE & HALF CORE
ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-1
Physical Parameters Cable Code : A2XFY/2XFY, A2XWY/2XWY
Flat Strip Armoured (A2XFY/2XFY) Round Wire Armoured (A2XWY/2XWY)
Minimum Minimum Approx. Weight of Cable Approx. Weight of Cable
Size Minimum No. of Nominal Nominal Approx. Nominal Minimum Approx.
Inner Outer
(Cross Strand in Conductor Insulation Armour Overall With Al'm With Cu Dia of Outer Overall With Al'm With Cu
Sheath Sheath Cond. Cond. Cond. Cond.
Sectional Thickness Strip Dia of Armor Sheath Dia of
Thick- Thick-
Area) Aluminium Copper Dimension Cable A2XFY 2XFY Wire Thickness Cable A2XWY 2XWY
ness ness
Sqmm No's No's mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
3X25 +16 6/6 6/6 0.90/0.70 0.30 4 X 0.80 1.40 22 800 1350 1.60 1.40 23 1000 1550
3X35 +16 6/6 6/6 0.90/0.70 0.30 4 X 0.80 1.40 24 950 1650 1.60 1.40 26 1200 1900
3X 50+25 6/6 6/6 1.00/0.90 0.30 4 X 0.80 1.40 27 1150 2150 1.60 1.56 28 1450 2400
3X70+35 12/6 12/6 1.10/0.90 0.40 4 X 0.80 1.56 31 1500 2850 2.00 1.56 33 2000 3400
3X95 +50 15/6 15/6 1.10/1.00 0.40 4 X 0.80 1.56 34 1850 3800 2.00 1.56 36 2400 4350
3X120+70 15/12 18/12 1.20/1.10 0.40 4 X 0.80 1.72 38 2250 4750 2.00 1.72 40 2900 5400
3X150+70 15/12 18/12 1.40/1.10 0.50 4 X 0.80 1.72 41 2650 5600 2.00 1.88 44 3400 6400
3X 185+95 30/15 30/15 1.60/1.10 0.50 4 X 0.80 1.88 46 3200 7000 2.50 2.04 50 4450 8200
3X240+120 30/15 34/18 1.70/1.20 0.60 4 X 0.80 2.04 50 4000 8900 2.50 2.2 54 5250 10200
3X300+150 30/15 34/18 1.80/1.40 0.60 4 X 0.80 2.2 55 4800 11000 2.50 2.36 59 6200 12400
3X400+185 53/30 53/30 2.00/1.60 0.70 4 X 0.80 2.52 62 5950 13850 3.15 2.68 66 8200 16050
3X500+240 53/30 53/34 2.20/1.70 0.70 4 X 0.80 2.68 72 7500 17650 3.15 2.84 77 10150 20250
3X630+300 53/30 53/34 2.40/1.80 0.70 4 X 0.80 3.00 80 9300 22400 4.00 3.00 86 13250 26300
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : XLPE (Cross linked polyethylene); Colour : Red, Yellow, Blue & Black
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Armouring : Single Layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Max. Conductor Approx. Conductor Short Circuit Current
Size Reactance Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C Capacitance Rating for 1 Second
(Cross of Cable
of Cable For Aluminium Conductor For Copper Conductor Duration
Sectional at 50 Hz
Aluminium Copper Aluminium Copper (Approx.)
Area) (Approx.) Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
3X25+16 1.20 0.727 1.54 0.931 0.080 0.20 95 80 99 120 100 125 2.35 3.58
3X35+16 0.868 0.524 1.11 0.671 0.080 0.23 116 94 117 145 120 155 3.29 5.01
3X50+25 0.641 0.387 0.820 0.495 0.078 0.24 140 110 140 170 145 190 4.70 7.15
3X70+35 0.443 0.268 0.567 0.343 0.077 0.26 170 140 176 210 175 235 6.58 10.01
3X95+50 0.320 0.193 0.411 0.248 0.074 0.29 200 165 221 250 210 290 8.93 13.59
3X120+70 0.253 0.153 0.325 0.197 0.072 0.29 225 185 258 285 240 330 11.28 17.16
3X150+70 0.206 0.1240 0.265 0.159 0.072 0.29 255 210 294 315 270 375 14.10 21.45
3X185+95 0.164 0.0991 0.211 0.127 0.072 0.29 285 235 339 355 300 435 17.39 26.46
3X240+120 0.125 0.0754 0.162 0.0976 0.072 0.31 325 270 402 410 350 510 22.56 34.32
3X300+150 0.100 0.0601 0.130 0.0778 0.071 0.33 370 305 461 460 390 590 28.20 42.90
3X400+185 0.0778 0.0470 0.1023 0.0618 0.070 0.33 435 350 542 520 440 670 37.60 57.20
3X500+240 0.0605 0.0366 0.0808 0.0489 0.070 0.34 481 405 624 580 480 750 47.00 71.50
3X630+300 0.0469 0.0283 0.0648 0.0391 0.069 0.36 537 470 723 680 575 875 59.22 90.09
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

32
LT/HT Power & Control Cables

Table - 22
TECHNICAL DETAILS FOR HAVELLS 1.1 KV
FOUR CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-1
Physical Parameters Cable Code : A2XFY/2XFY, A2XWY/2XWY
Flat Strip Armoured (A2XFY/2XFY) Round Wire Armoured (A2XWY/2XWY)
Size Nominal Minimum Nominal Minimum Approx. Approx. Weight of Cable Approx. Weight of Cable
Minimum No. of Nominal Minimum Approx.
(Cross Strand in Conductor Insulation Inner Armour Outer Overall With Al'm With Cu Dia of Outer Overall With Al'm With Cu
Sectional Thickness Sheath Strip Sheath Dia of Cond. Cond. Armor Sheath Dia of Cond. Cond.
Area) Aluminium Copper Thickness Dimension Thickness Cable A2XFY 2XFY Wire Thickness Cable A2XWY 2XWY
Sqmm No's No's mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
4 1/3 1/3 0.70 0.30 N/A N/A N/A N/A N/A 1.40 1.24 16 440 560
6 1/3 1/3 0.70 0.30 N/A N/A N/A N/A N/A 1.40 1.24 17 520 670
10 1/7 6 0.70 0.30 N/A N/A N/A N/A N/A 1.40 1.40 19 620 900
16 6 6 0.70 0.30 4 X 0.80 1.40 20 650 1000 1.60 1.40 21 850 1200
25 6 6 0.90 0.30 4 X 0.80 1.40 22 850 1450 1.60 1.40 24 1100 1700
35 6 6 0.90 0.30 4 X 0.80 1.40 25 1000 1850 1.60 1.40 26 1300 2100
50 6 6 1.00 0.30 4 X 0.80 1.56 28 1300 2400 1.60 1.56 29 1550 2700
70 12 12 1.10 0.40 4 X 0.80 1.56 32 1650 3250 2.00 1.56 34 2200 3800
95 15 15 1.10 0.40 4 X 0.80 1.56 35 2000 4250 2.00 1.72 38 2700 4900
120 15 18 1.20 0.50 4 X 0.80 1.72 39 2500 5300 2.00 1.88 42 3200 6000
150 15 18 1.40 0.50 4 X 0.80 1.88 43 2950 6400 2.50 2.04 47 4100 7550
185 30 30 1.60 0.50 4 X 0.80 2.04 48 3600 7950 2.50 2.20 52 4850 9150
240 30 34 1.70 0.60 4 X 0.80 2.20 54 4500 10200 2.50 2.36 58 5950 11600
300 30 34 1.80 0.70 4 X 0.80 2.36 61 5500 12600 3.15 2.52 66 7750 14850
400 53 53 2.00 0.70 4 X 0.80 2.68 68 6850 15900 3.15 2.84 73 9350 18400
500 53 53 2.20 0.70 4 X 0.80 2.84 75 8500 20100 4.00 3.00 82 12400 24000
630 53 53 2.40 0.70 4 X 0.80 3.00 84 10550 25650 4.00 3.00 91 14750 30000
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
Conductor Material : Aluminium / Copper as per Class-2 of IS: 8130
Shape of Conductor : For Al'm Cond. - 4, 6 & 10 Sq.mm Solid / Stranded Non Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
For Cu Cond. - 4 & 6 Sq.mm Solid / Stranded Non Compacted Circular, 10 Sq.mm - Stranded Compacted Circular,
16 Sq.mm and above - Stranded Compacted Shaped
Insulation Material : XLPE (Cross linked polyethylene); Colour : Red,Yellow, Blue & Black
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Armouring : Single Layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Max. Conductor Approx. Conductor Short Circuit Current
Size Reactance Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C Rating for 1 Second
(Cross of Cable Capacitance of
Sectional at 50 Hz Cable (Approx.) For Aluminium Conductor For Copper Conductor Duration
Aluminium Copper Aluminium Copper
Area) (Approx.) Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
4 7.41 4.61 9.48 5.90 0.098 0.11 34 28 30 44 37 39 0.376 0.572
6 4.61 3.08 5.90 3.94 0.090 0.13 43 37 40 55 47 50 0.564 0.858
10 3.08 1.83 3.94 2.34 0.084 0.16 57 48 53 74 61 67 0.940 1.43
16 1.91 1.15 2.44 1.47 0.080 0.18 78 61 70 94 78 85 1.50 2.29
25 1.20 0.727 1.54 0.931 0.080 0.20 95 80 99 120 100 125 2.35 3.58
35 0.868 0.524 1.11 0.671 0.080 0.23 116 94 117 145 120 155 3.29 5.01
50 0.641 0.387 0.820 0.495 0.078 0.24 140 110 140 170 145 190 4.70 7.15
70 0.443 0.268 0.567 0.343 0.077 0.26 170 140 176 210 175 235 6.58 10.01
95 0.320 0.193 0.411 0.248 0.074 0.29 200 165 221 250 210 290 8.93 13.59
120 0.253 0.153 0.325 0.197 0.072 0.29 225 185 258 285 240 330 11.28 17.16
150 0.206 0.1240 0.265 0.159 0.072 0.29 255 210 294 315 270 375 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.072 0.29 285 235 339 355 300 435 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.072 0.31 325 270 402 410 350 510 22.56 34.32
300 0.100 0.0601 0.130 0.0778 0.071 0.33 370 305 460 460 390 590 28.20 42.90
400 0.0778 0.0470 0.1023 0.0618 0.070 0.33 435 350 542 520 440 670 37.60 57.20
500 0.0605 0.0366 0.0808 0.0489 0.070 0.34 481 405 624 580 480 750 47.00 71.50
630 0.0469 0.0283 0.0648 0.0391 0.069 0.36 537 470 723 680 575 875 59.22 90.09
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

33
LT/HT Power & Control Cables

Table - 23
TECHNICAL DETAILS FOR HAVELLS 1.1 KV 1.5 SQMM
COPPER CONDUCTOR, XLPE INSULATED, ARMOURED / UNARMOURED CONTROL CABLES
Ref Specication : IS 7098 Part-1
Physical Parameters Cable Code : 2XY/2XFY/2XWY
Unarmoured (2XY) Flat Strip Armoured (2XFY) Round Wire Armoured (2XWY)

No. Minimum Nominal Approx. Minimum Approx. Approx. Weight of Nominal Minimum Approx. Approx. Weight of
Approx. Dimen-
of Inner Outer Overall Dia of Outer Overall Dia of Cable Dia of Outer Overall Dia of Cable
Weight of Cable sion of
Cores Sheath Sheath Cable Sheath Cable Armour Sheath Cable
Armour
Thickness Thickness Solid Std. Soild Std. Thick- Soild Std. Soild Std. Wire Thick- Soild Std. Soild Std.
Strip
Cond. cond. Cond cond. ness Cond cond. Cond cond. ness Cond cond. Cond cond.
Nos mm mm mm mm Kg/Km Kg/Km mm mm mm mm Kg/Km Kg/Km mm mm mm mm Kg/Km Kg/Km
2 0.30 1.80 10 10 150 150 N/A N/A N/A N/A N/A N/A 1.40 1.24 12 13 320 350
3 0.30 1.80 11 11 170 200 N/A N/A N/A N/A N/A N/A 1.40 1.24 13 13 330 350
4 0.30 1.80 12 12 200 200 N/A N/A N/A N/A N/A N/A 1.40 1.24 14 14 370 400
5 0.30 1.80 12 13 230 250 N/A N/A N/A N/A N/A N/A 1.40 1.24 14 15 420 450
6 0.30 1.80 13 14 260 300 N/A N/A N/A N/A N/A N/A 1.40 1.24 15 16 460 500
7 0.30 1.80 13 14 250 250 N/A N/A N/A N/A N/A N/A 1.40 1.24 15 16 470 500
10 0.30 1.80 16 16 340 350 N/A N/A N/A N/A N/A N/A 1.40 1.24 18 19 640 650
12 0.30 1.80 17 17 380 400 N/A N/A N/A N/A N/A N/A 1.40 1.40 19 20 750 800
14 0.30 1.80 17 18 420 450 N/A N/A N/A N/A N/A N/A 1.40 1.40 20 21 800 850
16 0.30 1.80 18 19 470 500 4x0.8 1.40 19 20 660 700 1.60 1.40 21 22 860 900
19 0.30 1.80 19 20 550 550 4x0.8 1.40 20 21 750 750 1.60 1.40 21 22 940 1000
24 0.30 2.00 22 23 680 700 4x0.8 1.40 23 24 920 950 1.60 1.40 24 25 1140 1200
27 0.30 2.00 23 24 730 750 4x0.8 1.40 23 24 970 1000 1.60 1.40 25 26 1210 1300
30 0.30 2.00 23 25 800 850 4x0.8 1.40 24 25 1030 1100 1.60 1.40 25 27 1290 1350
37 0.30 2.00 25 26 940 1000 4x0.8 1.40 25 27 1200 1250 1.60 1.40 27 29 1510 1600
40 0.30 2.00 26 27 1030 1080 4x0.8 1.40 26 28 1310 1380 1.60 1.40 28 29 1590 1680
44 0.30 2.00 28 30 1130 1170 4x0.8 1.40 28 30 1420 1490 1.60 1.56 31 32 1760 1850
52 0.30 2.00 29 31 1290 1340 4x0.8 1.56 30 32 1640 1710 1.60 1.56 32 33 1950 2050
61 0.40 2.20 31 33 1520 1580 4x0.8 1.56 32 34 1860 1940 2.00 1.56 34 36 2410 2520
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view

1 Conductor : Solid / Stranded Annealed Bare Copper as per Class-2 of IS: 8130; Options : Tinned
2 Insulation Material : XLPE as per IS: 5831; Nominal Insulation Thickness : 0.70 mm
Core Identication : Upto 5 cores : By colour coding & Above 5 cores : By colour coding / Number printing on cores
as per IS : 7098 Part-1
3
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
4 Armouring : Single Layer of Aluminium Round Wire / Flat Strip
5 Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Max. Conductor Normal Current Rating for XLPE Insulation Short Circuit Current
Number of Approx. Conductor Reactance of Cable Capacitance of
D.C.Resistance at Rating for 1 Second
Cores A.C.Resistance at 50 Hz (Approx.) Cable (Approx.) Ground Duct Air
20 C Duration
No's Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps K.amps
2 12.10 15.49 0.102 0.09 33 29 29 0.215
3 12.10 15.49 0.102 0.09 25 22 22 0.215
4 12.10 15.49 0.102 0.09 25 22 22 0.215
5 12.10 15.49 0.102 0.09 24 21 21 0.215
6 12.10 15.49 0.102 0.09 22 19 19 0.215
7 12.10 15.49 0.102 0.09 21 18 18 0.215
10 12.10 15.49 0.102 0.09 18 16 16 0.215
12 12.10 15.49 0.102 0.09 17 15 15 0.215
14 12.10 15.49 0.102 0.09 16 14 14 0.215
16 12.10 15.49 0.102 0.09 16 14 14 0.215
19 12.10 15.49 0.102 0.09 15 13 13 0.215
24 12.10 15.49 0.102 0.09 13 12 12 0.215
27 12.10 15.49 0.102 0.09 13 11 11 0.215
30 12.10 15.49 0.102 0.09 12 11 11 0.215
37 12.10 15.49 0.102 0.09 11 10 10 0.215
40 12.10 15.49 0.102 0.09 11 9 9 0.215
44 12.10 15.49 0.102 0.09 11 9 9 0.215
52 12.10 15.49 0.102 0.09 10 9 9 0.215
61 12.10 15.49 0.102 0.09 9 8 8 0.215
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

34
LT/HT Power & Control Cables

Table - 24
TECHNICAL DETAILS FOR HAVELLS 1.1 KV 2.5 SQMM
COPPER CONDUCTOR, XLPE INSULATED, ARMOURED / UNARMOURED CONTROL CABLES
Ref Specication : IS 7098 Part-1
Physical Parameters Cable Code : 2XY/2XFY/2XWY
Unarmoured (2XY) Flat Strip Armoured (2XFY) Round Wire Armoured (2XWY)

No. Minimum Nominal Approx. Approx. Minimum Approx. Approx. Weight of Nominal Minimum Approx. Approx. Weight of
Dimen-
of Inner Outer Overall Dia of Weight of Cable Outer Overall Dia of Cable Dia of Outer Overall Dia of Cable
sion of
Cores Sheath Sheath Cable Sheath Cable Armour Sheath Cable
Armour
Thickness Thickness Solid Std. Soild Std. Thick- Soild Std. Soild Std. Wire Thick- Soild Std. Soild Std.
Strip
Cond. cond. Cond cond. ness Cond cond. Cond cond. ness Cond cond. Cond cond.
Nos mm mm mm mm Kg/Km Kg/Km mm mm mm mm Kg/Km Kg/Km mm mm mm mm Kg/Km Kg/Km
2 0.30 1.80 11 12 180 200 N/A N/A N/A N/A N/A N/A 1.40 1.24 13 13 370 400
3 0.30 1.80 12 12 210 220 N/A N/A N/A N/A N/A N/A 1.40 1.24 14 14 390 410
4 0.30 1.80 13 13 250 270 N/A N/A N/A N/A N/A N/A 1.40 1.24 15 15 440 460
5 0.30 1.80 14 14 300 310 N/A N/A N/A N/A N/A N/A 1.40 1.24 15 16 500 520
6 0.30 1.80 15 15 350 360 N/A N/A N/A N/A N/A N/A 1.40 1.24 16 17 560 580
7 0.30 1.80 15 15 330 340 N/A N/A N/A N/A N/A N/A 1.40 1.24 16 17 590 610
10 0.30 1.80 18 19 450 470 4x0.8 1.24 19 20 650 690 1.60 1.40 20 21 850 880
12 0.30 1.80 19 20 530 550 4x0.8 1.40 19 20 700 750 1.60 1.40 21 22 920 950
14 0.30 1.80 20 21 590 610 4x0.8 1.40 20 21 790 830 1.60 1.40 22 23 1000 1030
16 0.30 2.00 21 22 660 680 4x0.8 1.40 21 22 880 900 1.60 1.40 23 24 1080 1130
19 0.30 2.00 22 23 750 780 4x0.8 1.40 22 23 970 1010 1.60 1.40 24 25 1200 1260
24 0.30 2.00 25 26 930 960 4x0.8 1.40 25 27 1190 1240 1.60 1.40 27 29 1480 1540
27 0.30 2.00 25 27 1020 1050 4x0.8 1.40 26 27 1300 1320 1.60 1.40 28 29 1580 1640
30 0.30 2.00 26 28 1110 1150 4x0.8 1.40 27 28 1410 1470 1.60 1.40 29 30 1690 1770
37 0.30 2.00 29 30 1370 1410 4x0.8 1.40 30 31 1690 1720 1.60 1.56 31 32 1980 2050
40 0.30 2.00 29 31 1450 1500 4x0.8 1.56 31 32 1800 1870 1.60 1.56 32 33 2110 2210
44 0.40 2.20 32 34 1630 1690 4x0.8 1.56 32 34 1990 2070 2.00 1.56 35 37 2520 2650
52 0.40 2.20 33 35 1870 1940 4x0.8 1.56 34 36 2250 2340 2.00 1.56 36 38 2810 2920
61 0.40 2.20 35 37 2150 2220 4x0.8 1.56 36 38 3160 2640 2.00 1.56 38 40 3160 3280
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.
** Refer page no. 55 for normal delivery lengths & packing details.

Cross-sectional view
1 Conductor : Solid / Stranded Annealed Bare Copper as per Class-2 of IS: 8130; Options : Tinned
2 Insulation Material : XLPE as per IS: 5831; Nominal Insulation Thickness : 0.70 mm
Core Identication : Upto 5 cores : By colour coding & Above 5 cores : By colour coding / Number printing on cores
as per IS : 7098 Part-1
3
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
4
Armouring : Single Layer of Aluminium Round Wire / Flat Strip
5 Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Max. Conductor Normal Current Rating for XLPE Insulation Short Circuit Current
Number of Approx. Conductor Reactance of Cable Capacitance of
D.C.Resistance at Rating for 1 Second
Cores A.C.Resistance at 50 Hz (Approx.) Cable (Approx.) Ground Duct Air
20 C Duration
No's Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps K.amps
2 7.41 9.48 0.100 0.10 39 32 32 0.358
3 7.41 9.48 0.100 0.10 34 30 30 0.358
4 7.41 9.48 0.100 0.10 34 30 30 0.358
5 7.41 9.48 0.100 0.10 31 28 28 0.358
6 7.41 9.48 0.100 0.10 29 26 26 0.358
7 7.41 9.48 0.100 0.10 27 25 25 0.358
10 7.41 9.48 0.100 0.10 24 21 21 0.358
12 7.41 9.48 0.100 0.10 22 20 20 0.358
14 7.41 9.48 0.100 0.10 21 19 19 0.358
16 7.41 9.48 0.100 0.10 20 18 18 0.358
19 7.41 9.48 0.100 0.10 19 17 17 0.358
24 7.41 9.48 0.100 0.10 17 16 16 0.358
27 7.41 9.48 0.100 0.10 16 16 16 0.358
30 7.41 9.48 0.100 0.10 16 14 14 0.358
37 7.41 9.48 0.100 0.10 15 13 13 0.358
40 7.41 9.48 0.100 0.10 14 13 13 0.358
44 7.41 9.48 0.100 0.10 14 13 13 0.358
52 7.41 9.48 0.100 0.10 13 12 12 0.358
61 7.41 9.48 0.100 0.10 12 11 11 0.358
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

35
HT POWER CABLE

HT POWER CABLE

36
FEATURES

HT POWER CABLE
s (IGHCONTINUOUSCURRENTRATING s &REEFROMHEIGHTLIMITATIONMAINTENANCE
s (IGHERSHORTCIRCUITRATING s 2ESISTANTTOVIBRATION MOISTURE CHEMICALCORROSSIVEGASES
s (IGHEMERGENCYLOADCAPACITY s -UCHLONGERLIFEOFTHECABLE
s ,OWDIELECTRICLOSS
s ,ONGERCHARGINGCURRNETS

APPLICABLE STANDARD
s )30ART 

37
LT/HT Power & Control Cables

Table - 25
TECHNICAL DETAILS FOR HAVELLS 3.3 KV
SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Physical Parameters Cable Code : A2XWaY/2XWaY (3.3KV - EARTHED / UNEARTHED)
Approx. Weight of Cable
Size Nominal Insulation Nominal Dia of Armor Minimum Outer Sheath Approx. Overall Dia of
(Cross Sectional Area) Thickness Wire Thickness Cable With Al'm Cond. With Cu Cond.
A2XWaY 2XWaY
Sqmm mm mm mm mm Kg/Km Kg/Km
25 2.50 1.40 1.24 17 350 500
35 2.50 1.40 1.24 18 400 600
50 2.50 1.40 1.40 19 500 750
70 2.50 1.60 1.40 21 600 1000
95 2.50 1.60 1.40 23 700 1250
120 2.50 1.60 1.40 24 800 1500
150 2.50 1.60 1.40 26 900 1800
185 2.50 1.60 1.40 27 1050 2150
240 2.50 1.60 1.56 30 1300 2700
300 2.50 1.60 1.56 32 1500 3300
400 2.60 2.00 1.56 36 1900 4200
500 2.80 2.00 1.56 41 2300 5250
630 3.00 2.00 1.72 45 2850 6650
800 3.30 2.00 1.88 51 3550 8450
1000 3.50 2.50 2.04 56 4450 10600
- Tabulated approx. net weights of cables are only for guidelines for transportation / loading/ unloading purpose.

Cross-sectional view

Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
Insulation Material : XLPE (Cross linked polyethylene); Colour : Natural
Armouring : Single Layer of Aluminium Round Wire
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Max. Conductor Approx. Conductor Short Circuit Current
Size Reactance Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C Rating for 1 Second
(Cross of Cable Capacitance of
Sectional at 50 Hz Cable (Approx.) For Aluminium Conductor For Copper Conductor Duration
Aluminium Copper Aluminium Copper
Area) (Approx.) Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
25 1.20 0.727 1.54 0.931 0.133 0.25 100 91 110 130 115 145 2.35 3.58
35 0.868 0.524 1.11 0.671 0.126 0.29 120 110 135 155 140 175 3.29 5.00
50 0.641 0.387 0.82 0.495 0.122 0.33 140 125 165 185 165 215 4.70 7.15
70 0.443 0.268 0.567 0.343 0.116 0.38 175 155 210 225 200 270 6.58 10.00
95 0.32 0.193 0.41 0.248 0.111 0.44 205 185 255 265 235 330 8.93 13.59
120 0.253 0.153 0.325 0.197 0.106 0.49 235 210 295 300 265 380 11.28 17.16
150 0.206 0.124 0.265 0.159 0.103 0.53 260 230 335 335 300 430 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.100 0.58 295 260 390 380 335 495 17.39 26.45
240 0.125 0.0754 0.162 0.0976 0.097 0.67 340 300 460 435 385 590 22.56 34.32
300 0.10 0.0601 0.130 0.0778 0.095 0.73 385 335 530 490 430 670 28.20 42.90
400 0.0778 0.047 0.1023 0.0618 0.093 0.84 440 380 620 550 480 780 37.60 57.20
500 0.0605 0.0366 0.0808 0.0489 0.091 0.86 495 430 730 610 530 900 47.00 71.50
630 0.0469 0.0283 0.0648 0.0391 0.090 0.88 560 485 840 680 590 1020 59.22 90.10
800 0.0367 0.0221 0.053 0.0319 0.088 0.94 620 530 960 740 630 1140 75.20 114.40
1000 0.0291 0.0176 0.0444 0.0268 0.086 0.99 670 570 1070 780 660 1250 94.00 143.00
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

38
LT/HT Power & Control Cables

Table - 26
TECHNICAL DETAILS FOR HAVELLS 3.3 KV
THREE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Physical Parameters Cable Code : A2XFY/2XFY, A2XWY/2XWY (3.3KV - EARTHED / UNEARTHED)
Flat Strip Armoured (A2XFY/2XFY) Round Wire Armoured (A2XWY/2XWY)
Size Approx. Weight of Cable Approx. Weight of Cable
Nominal Minimum Nominal Minimum Minimum
(Cross Approx. Nominal Dia Approx.
Insulation Inner Sheath Armour Outer With Al'm With Cu Outer With Al'm With Cu
Sectional Overall Dia of Armor Overall Dia
Thickness Thickness Strip Sheath Cond. Cond. Sheath Cond. Cond.
Area) of Cable Wire of Cable
Dimension Thickness A2XFY 2XFY Thickness A2XWY 2XWY
Sqmm mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
25 2.20 0.30 4 x 0.80 1.40 27 1000 1450 1.60 1.56 30 1300 1750
35 2.20 0.30 4 x 0.80 1.56 29 1200 1800 1.60 1.56 33 1500 2100
50 2.20 0.40 4 x 0.80 1.56 31 1400 2250 2.00 1.56 35 1900 2750
70 2.20 0.40 4 x 0.80 1.56 34 1650 2900 2.00 1.56 38 2250 3450
95 2.20 0.40 4 x 0.80 1.72 37 2000 3700 2.00 1.72 42 2650 4300
120 2.20 0.50 4 x 0.80 1.72 40 2350 4450 2.00 1.88 45 3050 5150
150 2.20 0.50 4 x 0.80 1.88 43 2700 5300 2.50 2.04 48 3750 6400
185 2.20 0.50 4 x 0.80 2.04 46 3150 6450 2.50 2.04 51 4300 7600
240 2.20 0.60 4 x 0.80 2.2 51 3850 8150 2.50 2.20 56 5050 9400
300 2.20 0.60 4 x 0.80 2.2 55 4350 9900 2.50 2.36 60 5800 11250
400 2.20 0.70 4 x 0.80 2.36 61 5400 12350 3.15 2.68 67 7700 14600
- Tabulated approx. net weights of cables are only for guidelines for transportation / loading/ unloading purpose.

Cross-sectional view

Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
Insulation Material : XLPE (Cross linked polyethylene); Colour : Red, Yellow & Blue
Inner Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Armouring : Single Layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other Colour as per requirement

Electrical Parameters
Max. Conductor Approx. Conductor Short Circuit Current
Size Reactance Normal Current Rating
D.C.Resistance at 20 C A.C.Resistance at 90 C Rating for 1 Second
(Cross of Cable Capacitance of
Sectional at 50 Hz Cable (Approx.) For Aluminium Conductor For Copper Conductor Duration
Aluminium Copper Aluminium Copper
Area) (Approx.) Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
25 1.20 0.727 1.54 0.931 0.098 0.25 94 80 99 120 100 125 2.35 3.58
35 0.868 0.524 1.11 0.671 0.094 0.29 115 95 120 145 120 155 3.29 5.00
50 0.641 0.387 0.82 0.495 0.086 0.33 135 110 145 170 145 190 4.70 7.15
70 0.443 0.268 0.567 0.343 0.084 0.38 165 140 185 210 175 235 6.58 10.01
95 0.32 0.193 0.41 0.248 0.081 0.44 195 165 225 250 210 290 8.93 13.59
120 0.253 0.153 0.325 0.197 0.078 0.49 220 185 255 285 240 330 11.28 17.16
150 0.206 0.124 0.265 0.159 0.076 0.53 245 210 295 315 270 375 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.075 0.58 280 235 340 355 300 435 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.073 0.67 320 270 400 410 350 510 22.56 34.32
300 0.1 0.0601 0.13 0.0778 0.072 0.73 360 305 460 460 390 590 28.20 42.90
400 0.0778 0.047 0.1023 0.0618 0.071 0.84 410 350 535 520 440 670 37.60 57.20
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

39
LT/HT Power & Control Cables

Table - 27
TECHNICAL DETAILS FOR HAVELLS 3.3 KV
SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Physical Parameters Cable Code : A2XFaY/2XFaY, A2XWaY/2XWaY (3.3KV - EARTHED / UNEARTHED)
Flat Strip Armoured (A2XFaY/2XFaY) Round Wire Armoured (A2XWaY/2XWaY)
Approx. Weight of Approx. Weight of
Size Nominal Minimum Nominal Minimum Approx. Cable Cable
(Cross insulation Inner Nominal dia Minimum Approx.
Armour Outer Overall With Alm With Cu With Alm With Cu
Sectional thickness Sheath of armor wire Outer Sheath Overall Dia
Strip Sheath Dia of Cond. Cond. Cond. Cond.
Area) Thickness Thickness of Cable
Dimension Thickness Cable A2XFaY 2XFaY A2XWaY 2XWaY
Sqmm mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
25 2.50 0.30 4 X 0.80 1.40 18 450 550 1.60 1.40 20 500 650
35 2.50 0.30 4 X 0.80 1.40 19 500 650 1.60 1.40 21 550 750
50 2.50 0.30 4 X 0.80 1.40 21 550 800 1.60 1.40 22 650 900
70 2.50 0.30 4 X 0.80 1.40 22 650 1050 1.60 1.40 24 750 1150
95 2.50 0.30 4 X 0.80 1.40 24 750 1300 1.60 1.40 25 850 1400
120 2.50 0.30 4 X 0.80 1.40 25 850 1550 1.60 1.40 27 950 1650
150 2.50 0.30 4 X 0.80 1.40 27 1000 1800 1.60 1.56 29 1100 1950
185 2.50 0.30 4 X 0.80 1.56 29 1150 2200 1.60 1.56 30 1250 2300
240 2.50 0.40 4 X 0.80 1.56 31 1400 2750 2.00 1.56 34 1550 2950
300 2.50 0.40 4 X 0.80 1.56 33 1600 3300 2.00 1.56 36 1800 3550
400 2.60 0.40 4 X 0.80 1.56 37 1900 4100 2.00 1.72 40 2200 4450
500 2.80 0.40 4 X 0.80 1.72 42 2400 5200 2.00 1.72 44 2650 5550
630 3.00 0.50 4 X 0.80 1.88 46 3000 6600 2.00 1.88 49 3250 7000
800 3.30 0.50 4 X 0.80 1.88 51 3650 8300 2.50 2.04 55 4100 8900
1000 3.50 0.60 4 X 0.80 2.04 56 4400 10250 2.50 2.20 59 4950 10950
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Cross-sectional view
1. Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
2. Conductor Screening : Extruded Semiconductor Compound
3. Insulation Material : XLPE (Cross linked polyethylene)
4. Insulation Screening : Extruded Semiconducting Compound followed by helically wrapped
Copper Tape
5. Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
6. Armouring : Single layer of Aluminium Round Wire / Flat Strip
7. Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : FR Type/FRLS Type
Colour of Outer Sheath : Black or any other color as per requirement
Electrical Parameters
Max. Conductor Approx. Conductor
Size D.C.Resistance at A.C.Resistance at Normal Current Rating Short Circuit Current
Reactance Capacitance Rating for 1 Second
(Cross 20 C 90 C
of Cable at of Cable Duration
Sectional
50 Hz (Approx.) For Aluminium Conductor For Copper Conductor
Area) Aluminium Copper Aluminium Copper (Approx.) Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
25 1.20 0.727 1.54 0.931 0.133 0.25 100 91 110 130 115 145 2.35 3.58
35 0.868 0.524 1.11 0.671 0.126 0.29 120 110 135 155 140 175 3.29 5.01
50 0.641 0.387 0.820 0.495 0.122 0.33 140 125 165 185 165 215 4.70 7.15
70 0.443 0.268 0.567 0.343 0.116 0.38 175 155 210 225 200 270 6.58 10.01
95 0.320 0.193 0.410 0.248 0.111 0.44 205 185 255 265 235 330 8.93 13.59
120 0.253 0.153 0.325 0.197 0.106 0.49 235 210 295 300 265 380 11.28 17.16
150 0.206 0.124 0.265 0.159 0.103 0.53 260 230 335 335 300 430 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.100 0.58 295 260 390 380 335 495 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.097 0.67 340 300 460 435 385 590 22.56 34.32
300 0.100 0.0601 0.130 0.0778 0.095 0.73 385 335 530 490 430 670 28.20 42.90
400 0.0778 0.0470 0.1023 0.0618 0.093 0.84 440 380 620 550 480 780 37.60 57.20
500 0.0605 0.0366 0.0808 0.0489 0.091 0.86 495 430 730 610 530 900 47.00 71.50
630 0.0469 0.0283 0.0648 0.0391 0.090 0.88 560 485 840 680 590 1020 59.22 90.10
800 0.0367 0.0221 0.0530 0.0319 0.088 0.94 620 530 960 740 630 1140 75.20 114.40
1000 0.0291 0.0176 0.0444 0.0268 0.086 0.99 670 570 1070 780 660 1250 94.00 143.00
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

40
LT/HT Power & Control Cables

Table - 28
TECHNICAL DETAILS FOR HAVELLS 3.3 KV
THREE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Physical Parameters Cable Code : A2XFY/2XFY, A2XWY/2XWY (3.3KV - EARTHED / UNEARTHED)
Flat Strip Armoured (A2XFY/2XFY) Round Wire Armoured (A2XWaY/2XWaY)
Approx. Weight of Approx. Weight of
Size Nominal Minimum Nominal Minimum Approx. Cable Cable
Minimum Approx.
(Cross insulation Inner Armour Outer Overall Nominal dia
With Alm With Cu Outer Sheath Overall Dia With Alm With Cu
Sectional thickness Sheath Strip Sheath Dia of of armor wire
Cond. Cond. Thickness of Cable Cond. Cond.
Area) Thickness Dimension Thickness Cable
A2XFY 2XFY A2XWY 2XWY
Sqmm mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
25 2.20 0.40 4 X 0.80 1.56 32 1450 1850 2.00 1.56 35 2000 2400
35 2.20 0.40 4 X 0.80 1.56 35 1700 2250 2.00 1.72 37 2300 2850
50 2.20 0.40 4 X 0.80 1.72 38 2000 2750 2.00 1.72 40 2650 3350
70 2.20 0.50 4 X 0.80 1.72 41 2350 3500 2.00 1.88 44 3100 4200
95 2.20 0.50 4 X 0.80 1.88 45 2800 4350 2.50 2.04 49 3950 5500
120 2.20 0.50 4 X 0.80 2.04 48 3250 5200 2.50 2.04 52 4500 6350
150 2.20 0.60 4 X 0.80 2.04 52 3700 6150 2.50 2.20 56 5000 7400
185 2.20 0.60 4 X 0.80 2.20 56 4300 7350 2.50 2.36 60 5750 8750
240 2.20 0.60 4 X 0.80 2.36 61 5150 9200 2.50 2.36 64 6600 10600
300 2.20 0.70 4 X 0.80 2.52 66 6050 11100 3.15 2.68 71 8350 13350
400 2.20 0.70 4 X 0.80 2.68 73 7300 13800 3.15 2.84 78 9850 16300
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Cross-sectional view
Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
Conductor Screening : Extruded Semiconductor Compound
Insulation Material : XLPE (Cross linked polyethylene )
Insulation Screening : Extruded Semiconducting Compound followed by helically wrapped Copper Tape
Filler : PVC Filler
Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Armouring : Single layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other color as per requirement

Electrical Parameters
Max. Conductor Approx. Conductor
Size D.C.Resistance at A.C.Resistance at Reactance Normal Current Rating Short Circuit Current
Capacitance Rating for 1 Second
(Cross 20 C 90 C of Cable at
of Cable Duration
Sectional 50 Hz
(Approx.) For Aluminium Conductor For Copper Conductor
Area) Aluminium Copper Aluminium Copper (Approx.)
Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
25 1.20 0.727 1.54 0.931 0.098 0.25 94 80 99 120 100 125 2.35 3.58
35 0.868 0.524 1.11 0.671 0.094 0.29 115 95 120 145 120 155 3.29 5.01
50 0.641 0.387 0.820 0.495 0.086 0.33 135 110 145 170 145 190 4.70 7.15
70 0.443 0.268 0.567 0.343 0.084 0.38 165 140 185 210 175 235 6.58 10.01
95 0.320 0.193 0.410 0.248 0.081 0.44 195 165 225 250 210 290 8.93 13.59
120 0.253 0.153 0.325 0.197 0.078 0.49 220 185 255 285 240 330 11.28 17.16
150 0.206 0.124 0.265 0.159 0.076 0.53 245 210 295 315 270 375 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.075 0.58 280 235 340 355 300 435 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.073 0.67 320 270 400 410 350 510 22.56 34.32
300 0.100 0.0601 0.130 0.0778 0.072 0.73 360 305 460 460 390 590 28.20 42.90
400 0.0778 0.0470 0.1023 0.0618 0.071 0.84 410 350 535 520 440 670 37.60 57.20
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

41
LT/HT Power & Control Cables

Table - 29
TECHNICAL DETAILS FOR HAVELLS 3.8/6.6 KV
SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Physical Parameters Cable Code : A2XFaY/2XFaY, A2XWaY/2XWaY (6.6KV EARTHED)
Flat Strip Armoured (A2XFaY/2XFaY) Round Wire Armoured (A2XWaY/2XWaY)
Approx. Weight of Approx. Weight of
Size Nominal Minimum Nominal Minimum Approx. Cable Cable
(Cross insulation Inner Nominal dia Minimum Approx.
Armour Outer Overall With Alm With Cu With Alm With Cu
Sectional thickness Sheath of armor wire Outer Sheath Overall Dia
Strip Sheath Dia of Cond. Cond. Cond. Cond.
Area) Thickness Thickness of Cable
Dimension Thickness Cable A2XFaY 2XFaY A2XWaY 2XWaY
Sqmm mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
25 2.80 0.30 4 X 0.80 1.40 19 450 600 1.60 1.40 21 550 650
35 2.80 0.30 4 X 0.80 1.40 20 500 700 1.60 1.40 22 600 800
50 2.80 0.30 4 X 0.80 1.40 21 600 850 1.60 1.40 23 650 950
70 2.80 0.30 4 X 0.80 1.40 23 700 1050 1.60 1.40 24 750 1150
95 2.80 0.30 4 X 0.80 1.40 24 800 1300 1.60 1.40 26 900 1450
120 2.80 0.30 4 X 0.80 1.40 26 900 1550 1.60 1.40 27 1000 1700
150 2.80 0.30 4 X 0.80 1.40 27 1000 1850 1.60 1.56 29 1150 2000
185 2.80 0.30 4 X 0.80 1.56 30 1200 2200 1.60 1.56 31 1300 2350
240 2.80 0.40 4 X 0.80 1.56 32 1400 2750 2.00 1.56 34 1600 3000
300 3.00 0.40 4 X 0.80 1.56 34 1650 3350 2.00 1.56 37 1850 3650
400 3.30 0.40 4 X 0.80 1.56 38 2000 4200 2.00 1.72 41 2300 4550
500 3.50 0.50 4 X 0.80 1.72 43 2550 5300 2.00 1.88 46 2800 5700
630 3.50 0.50 4 X 0.80 1.88 47 3050 6700 2.00 1.88 50 3350 7100
800 3.50 0.50 4 X 0.80 1.88 52 3700 8300 2.50 2.04 55 4150 8950
1000 3.60 0.60 4 X 0.80 2.04 56 4450 10250 2.50 2.20 59 4950 11000
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Cross-sectional view
1. Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
2. Conductor Screening : Extruded Semiconductor Compound
3. Insulation Material : XLPE (Cross linked polyethylene )
4. Insulation Screening : Extruded Semiconducting Compound followed by hellically
wrapped Copper Tape
5. Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
6. Armouring : Single layer of Aluminium Round Wire / Flat Strip
7. Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other color as per requirement
Electrical Parameters
Max. Conductor Approx. Conductor
Size D.C.Resistance at A.C.Resistance at Normal Current Rating Short Circuit Current
Reactance Capacitance Rating for 1 Second
(Cross 20 C 90 C
of Cable at of Cable Duration
Sectional
50 Hz (Approx.) For Aluminium Conductor For Copper Conductor
Area) Aluminium Copper Aluminium Copper (Approx.) Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
25 1.20 0.727 1.54 0.931 0.149 0.21 100 90 120 130 115 155 2.35 3.58
35 0.868 0.524 1.11 0.671 0.142 0.24 120 105 145 155 140 185 3.29 5.01
50 0.641 0.387 0.820 0.495 0.133 0.27 140 125 170 185 160 220 4.70 7.15
70 0.443 0.268 0.567 0.343 0.127 0.31 175 155 215 225 195 275 6.58 10.01
95 0.320 0.193 0.410 0.248 0.121 0.36 205 180 260 265 235 340 8.93 13.59
120 0.253 0.153 0.325 0.197 0.116 0.39 235 205 305 300 265 390 11.28 17.16
150 0.206 0.124 0.265 0.159 0.113 0.43 260 230 345 335 295 440 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.109 0.47 295 260 395 380 330 510 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.105 0.53 340 300 470 435 380 600 22.56 34.32
300 0.100 0.0601 0.130 0.0778 0.104 0.54 385 335 540 490 425 680 28.20 42.90
400 0.0778 0.0470 0.1023 0.0618 0.102 0.57 440 380 630 550 480 790 37.60 57.20
500 0.0605 0.0366 0.0808 0.0489 0.100 0.60 495 430 730 610 530 910 47.00 71.50
630 0.0469 0.0283 0.0648 0.0391 0.096 0.67 560 480 840 680 580 1030 59.22 90.10
800 0.0367 0.0221 0.0530 0.0319 0.094 0.76 620 530 960 740 630 1140 75.20 114.40
1000 0.0291 0.0176 0.0444 0.0268 0.092 0.82 680 580 1070 790 670 1250 94.00 143.00
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

42
LT/HT Power & Control Cables

Table - 30
TECHNICAL DETAILS FOR HAVELLS 3.8/6.6 KV
THREE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Physical Parameters Cable Code : A2XFY/2XFY, A2XWY/2XWY (6.6KV EARTHED)
Flat Strip Armoured (A2XFY/2XFY) Round Wire Armoured (A2XWaY/2XWaY)
Approx. Weight of Approx. Weight of
Size Nominal Minimum Nominal Minimum Approx. Cable Cable
Minimum Approx.
(Cross insulation Inner Armour Outer Overall Nominal dia
With Alm With Cu Outer Sheath Overall Dia With Alm With Cu
Sectional thickness Sheath Strip Sheath Dia of of armor wire
Cond. Cond. Thickness of Cable Cond. Cond.
Area) Thickness Dimension Thickness Cable
A2XFY 2XFY A2XWY 2XWY
Sqmm mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
25 2.80 0.40 4 X 0.80 1.56 35 1650 2050 2.00 1.56 38 2300 2650
35 2.80 0.40 4 X 0.80 1.72 38 1900 2450 2.00 1.72 40 2550 3050
50 2.80 0.50 4 X 0.80 1.72 41 2200 2950 2.00 1.72 43 2950 3650
70 2.80 0.50 4 X 0.80 1.88 44 2600 3700 2.00 1.88 47 3350 4400
95 2.80 0.50 4 X 0.80 1.88 48 3050 4600 2.50 2.04 51 4250 5750
120 2.80 0.60 4 X 0.80 2.04 51 3500 5450 2.50 2.04 55 4800 6700
150 2.80 0.60 4 X 0.80 2.20 55 4000 6450 2.50 2.20 58 5350 7750
185 2.80 0.60 4 X 0.80 2.20 58 4550 7600 2.50 2.36 62 6050 9050
240 2.80 0.70 4 X 0.80 2.36 64 5450 9450 3.15 2.36 69 7700 11650
300 3.00 0.70 4 X 0.80 2.52 69 6450 11550 3.15 2.68 74 8950 13900
400 3.30 0.70 4 X 0.80 2.84 78 8000 14450 4.00 2.84 85 11850 18200
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Cross-sectional view

Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
Conductor Screening: Extruded Semiconducting Compound
Insulation Material: Crosslinked Polyethylene (Xlpe)
Insulation Screening: Extruded Semiconducting Compound Followed By Helically Wrapped Copper Tape.
Pvc Fillers
Inner Sheath: Extruded Pvc
Armouring: Single Layer Of Galvanized Flat Strip/ Round Wires.
Outer Sheath: Pvc Type St-2 Of Is: 5831 Options: Pvc Type St-2/ Fr Type/ Frls Type
Colour Of Outer Sheath: Black. Options: Any Other Colours As Per Requirement

Electrical Parameters
Max. Conductor Approx. Conductor
Size D.C.Resistance at A.C.Resistance at Reactance Normal Current Rating Short Circuit Current
Capacitance Rating for 1 Second
(Cross 20 C 90 C of Cable at
of Cable Duration
Sectional 50 Hz
(Approx.) For Aluminium Conductor For Copper Conductor
Area) Aluminium Copper Aluminium Copper (Approx.)
Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
25 1.20 0.727 1.54 0.931 0.126 0.21 95 82 105 120 105 135 2.35 3.58
35 0.868 0.524 1.11 0.671 0.120 0.24 115 97 125 145 125 165 3.29 5.01
50 0.641 0.387 0.820 0.495 0.114 0.27 130 115 150 170 150 195 4.70 7.15
70 0.443 0.268 0.567 0.343 0.107 0.31 160 140 190 210 180 240 6.58 10.01
95 0.320 0.193 0.410 0.248 0.102 0.36 190 165 230 250 215 295 8.93 13.59
120 0.253 0.153 0.325 0.197 0.098 0.39 220 190 260 280 240 335 11.28 17.16
150 0.206 0.124 0.265 0.159 0.095 0.43 245 210 295 310 270 380 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.093 0.47 275 240 335 350 305 430 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.090 0.53 315 275 395 400 350 500 22.56 34.32
300 0.100 0.0601 0.130 0.0778 0.090 0.54 355 310 450 445 390 570 28.20 42.90
400 0.0778 0.0470 0.1023 0.0618 0.087 0.57 400 350 520 500 440 650 37.60 57.20
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

43
LT/HT Power & Control Cables

Table - 31
TECHNICAL DETAILS FOR HAVELLS 6.6/6.6KV & 6.35/11 KV
SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Physical Parameters Cable Code : A2XFaY/2XFaY, A2XWaY/2XWaY (6.6KV UNEARTHED / 11KV EARTHED GRADE)
Flat Strip Armoured (A2XFaY/2XFaY) Round Wire Armoured (A2XWaY/2XWaY)
Approx. Weight of Approx. Weight of
Size Nominal Minimum Nominal Minimum Approx. Cable Cable
(Cross insulation Inner Nominal dia Minimum Approx.
Armour Outer Overall With Alm With Cu With Alm With Cu
Sectional thickness Sheath of armor wire Outer Sheath Overall Dia
Strip Sheath Dia of Cond. Cond. Cond. Cond.
Area) Thickness Thickness of Cable
Dimension Thickness Cable A2XFaY 2XFaY A2XWaY 2XWaY
Sqmm mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
25 3.60 0.30 4 X 0.80 1.40 21 500 650 1.60 1.40 22 600 750
35 3.60 0.30 4 X 0.80 1.40 22 600 750 1.60 1.40 23 650 850
50 3.60 0.30 4 X 0.80 1.40 23 650 900 1.60 1.40 25 750 1000
70 3.60 0.30 4 X 0.80 1.40 24 750 1100 1.60 1.40 26 850 1250
95 3.60 0.30 4 X 0.80 1.40 26 900 1400 1.60 1.40 28 950 1500
120 3.60 0.30 4 X 0.80 1.40 27 950 1650 1.60 1.56 29 1100 1800
150 3.60 0.30 4 X 0.80 1.56 29 1100 1950 1.60 1.56 31 1250 2100
185 3.60 0.40 4 X 0.80 1.56 31 1300 2300 2.00 1.56 34 1500 2550
240 3.60 0.40 4 X 0.80 1.56 34 1500 2850 2.00 1.56 36 1700 3100
300 3.60 0.40 4 X 0.80 1.56 35 1700 3400 2.00 1.56 38 1950 3700
400 3.60 0.40 4 X 0.80 1.72 39 2100 4250 2.00 1.72 41 2350 4600
500 3.60 0.50 4 X 0.80 1.72 44 2550 5300 2.00 1.88 46 2850 5750
630 3.60 0.50 4 X 0.80 1.88 48 3100 6700 2.00 1.88 50 3350 7100
800 3.60 0.50 4 X 0.80 1.88 52 3700 8300 2.50 2.04 55 4200 9000
1000 3.60 0.60 4 X 0.80 2.04 50 4450 10250 2.50 2.20 60 5000 11000
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Cross-sectional view
1. Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
2. Conductor Screening : Extruded Semiconductor Compound
3. Insulation Material : XLPE (Cross linked polyethylene)
4. Insulation Screening : Extruded Semiconducting Compound followed by hellically
wrapped Copper Tape
5. Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
6. Armouring : Single layer of Aluminium Round Wire / Flat Strip
7. Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other color as per requirement
Electrical Parameters
Max. Conductor Approx. Conductor
Size D.C.Resistance at A.C.Resistance at Normal Current Rating Short Circuit Current
Reactance Capacitance Rating for 1 Second
(Cross 20 C 90 C
of Cable at of Cable Duration
Sectional
50 Hz (Approx.) For Aluminium Conductor For Copper Conductor
Area) Aluminium Copper Aluminium Copper (Approx.) Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
25 1.20 0.727 1.54 0.931 0.164 0.18 100 90 120 130 115 155 2.35 3.58
35 0.868 0.524 1.11 0.671 0.156 0.20 120 105 145 155 140 185 3.29 5.01
50 0.641 0.387 0.820 0.495 0.147 0.22 140 125 170 185 160 220 4.70 7.15
70 0.443 0.268 0.567 0.343 0.139 0.26 175 155 215 225 195 275 6.58 10.01
95 0.320 0.193 0.410 0.248 0.133 0.29 205 180 260 265 235 340 8.93 13.59
120 0.253 0.153 0.325 0.197 0.127 0.32 235 205 305 300 265 390 11.28 17.16
150 0.206 0.124 0.265 0.159 0.124 0.35 260 230 345 335 295 440 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.120 0.38 295 260 395 380 330 510 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.117 0.43 340 300 470 435 380 600 22.56 34.32
300 0.100 0.0601 0.130 0.0778 0.113 0.46 385 335 540 490 425 680 28.20 42.90
400 0.0778 0.0470 0.1023 0.0618 0.110 0.53 440 380 630 550 480 790 37.60 57.20
500 0.0605 0.0366 0.0808 0.0489 0.107 0.59 495 430 730 610 530 910 47.00 71.50
630 0.0469 0.0283 0.0648 0.0391 0.104 0.66 560 480 840 680 580 1030 59.22 90.10
800 0.0367 0.0221 0.0530 0.0319 0.100 0.74 620 530 960 740 630 1140 75.20 114.40
1000 0.0291 0.0176 0.0444 0.0268 0.098 0.82 680 580 1070 790 670 1250 94.00 143.00
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

44
LT/HT Power & Control Cables

Table - 32
TECHNICAL DETAILS FOR HAVELLS 6.6/6.6KV & 6.35/11 KV
THREE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Physical Parameters Cable Code : A2XFY/2XFY, A2XWY/2XWY (6.6KV UNEARTHED / 11KV EARTHED GRADE)
Flat Strip Armoured (A2XFY/2XFY) Round Wire Armoured (A2XWaY/2XWaY)
Approx. Weight of Approx. Weight of
Size Nominal Minimum Nominal Minimum Approx. Cable Cable
Minimum Approx.
(Cross insulation Inner Armour Outer Overall Nominal dia
With Alm With Cu Outer Sheath Overall Dia With Alm With Cu
Sectional thickness Sheath Strip Sheath Dia of of armor wire
Cond. Cond. Thickness of Cable Cond. Cond.
Area) Thickness Dimension Thickness Cable
A2XFY 2XFY A2XWY 2XWY
Sqmm mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
25 3.60 0.40 4 X 0.80 1.72 39 1950 2350 2.00 1.72 41 2600 2950
35 3.60 0.50 4 X 0.80 1.72 41 2250 2750 2.00 1.88 44 2950 3450
50 3.60 0.50 4 X 0.80 1.88 44 2550 3250 2.50 2.04 48 3650 4350
70 3.60 0.50 4 X 0.80 1.88 48 2900 4000 2.50 2.04 51 4100 5150
95 3.60 0.60 4 X 0.80 2.04 52 3450 4950 2.50 2.20 55 4750 6250
120 3.60 0.60 4 X 0.80 2.20 55 3900 5850 2.50 2.36 58 5250 7200
150 3.60 0.60 4 X 0.80 2.20 58 4350 6800 2.50 2.36 62 5850 8200
185 3.60 0.70 4 X 0.80 2.36 62 5050 8050 3.15 2.52 67 7250 10200
240 3.60 0.70 4 X 0.80 2.52 67 5950 9950 3.15 2.68 73 8300 12200
300 3.60 0.70 4 X 0.80 2.68 72 6850 11900 3.15 2.84 77 9400 14400
400 3.60 0.70 4 X 0.80 2.84 79 8200 14650 4.00 3.00 86 12100 18450
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Cross-sectional view
Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
Conductor Screening : Extruded Semiconductor Compound
Insulation Material : XLPE (Cross linked polyethylene)
Insulation Screening : Extruded Semiconducting Compound followed by helically wrapped Copper Tape
Filler : PVC Filler
Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Armouring : Single layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other color as per requirement

Electrical Parameters
Max. Conductor Approx. Conductor
Size D.C.Resistance at A.C.Resistance at Reactance Normal Current Rating Short Circuit Current
Capacitance Rating for 1 Second
(Cross 20 C 90 C of Cable at
of Cable Duration
Sectional 50 Hz
(Approx.) For Aluminium Conductor For Copper Conductor
Area) Aluminium Copper Aluminium Copper (Approx.)
Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
25 1.20 0.727 1.54 0.931 0.133 0.18 95 82 105 120 105 135 2.35 3.58
35 0.868 0.524 1.11 0.671 0.126 0.20 115 97 125 145 125 165 3.29 5.01
50 0.641 0.387 0.820 0.495 0.118 0.22 130 115 150 170 150 195 4.70 7.15
70 0.443 0.268 0.567 0.343 0.116 0.26 160 140 190 210 180 240 6.58 10.01
95 0.320 0.193 0.410 0.248 0.107 0.29 190 165 230 250 215 295 8.93 13.59
120 0.253 0.153 0.325 0.197 0.102 0.32 220 190 260 280 240 335 11.28 17.16
150 0.206 0.124 0.265 0.159 0.099 0.35 245 210 295 310 270 380 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.097 0.38 275 240 335 350 305 430 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.084 0.43 315 275 395 400 350 500 22.56 34.32
300 0.100 0.0601 0.130 0.0778 0.083 0.46 355 310 450 445 390 570 28.20 42.90
400 0.0778 0.0470 0.1023 0.0618 0.089 0.53 400 350 520 500 440 650 37.60 57.20
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

45
LT/HT Power & Control Cables

Table - 33
TECHNICAL DETAILS FOR HAVELLS 11/11 KV
SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Physical Parameters Cable Code : A2XFaY/2XFaY, A2XWaY/2XWaY (11KV UNEARTHED GRADE)
Flat Strip Armoured (A2XFaY/2XFaY) Round Wire Armoured (A2XWaY/2XWaY)
Approx. Weight of Approx. Weight of
Size Nominal Minimum Nominal Minimum Approx. Cable Cable
(Cross insulation Inner Nominal dia Minimum Approx.
Armour Outer Overall With Alm With Cu With Alm With Cu
Sectional thickness Sheath of armor wire Outer Sheath Overall Dia
Strip Sheath Dia of Cond. Cond. Cond. Cond.
Area) Thickness Thickness of Cable
Dimension Thickness Cable A2XFaY 2XFaY A2XWaY 2XWaY
Sqmm mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
25 5.50 0.30 4 X 0.80 1.40 24 700 800 1.60 1.40 26 800 900
35 5.50 0.30 4 X 0.80 1.40 26 750 900 1.60 1.56 27 850 1050
50 5.50 0.30 4 X 0.80 1.40 27 800 1100 1.60 1.56 29 950 1200
70 5.50 0.30 4 X 0.80 1.56 29 950 1300 1.60 1.56 30 1050 1450
95 5.50 0.30 4 X 0.80 1.56 30 1100 1600 2.00 1.56 32 1200 1850
120 5.50 0.40 4 X 0.80 1.56 32 1200 1900 2.00 1.56 34 1400 2100
150 5.50 0.40 4 X 0.80 1.56 34 1350 2150 2.00 1.56 36 1550 2400
185 5.50 0.40 4 X 0.80 1.56 35 1500 2500 2.00 1.56 38 1700 2800
240 5.50 0.40 4 X 0.80 1.56 37 1750 3100 2.00 1.72 40 2000 3400
300 5.50 0.40 4 X 0.80 1.72 40 2000 3700 2.00 1.72 42 2250 4000
400 5.50 0.50 4 X 0.80 1.72 43 2400 4550 2.00 1.88 46 2700 4950
500 5.50 0.50 4 X 0.80 1.88 48 2900 5650 2.50 2.04 51 3300 6200
630 5.50 0.50 4 X 0.80 1.88 51 3400 7000 2.50 2.04 55 3900 7600
800 5.50 0.60 4 X 0.80 2.04 56 4100 8700 2.50 2.20 60 4650 9450
1000 5.50 0.60 4 X 0.80 2.20 60 4850 10650 2.50 2.36 64 5400 11450
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Cross-sectional view
1. Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
2. Conductor Screening: Extruded Semiconducting Compound
3. Insulation Material : XLPE (Cross linked polyethylene)
4. Insulation Screening : Extruded Semiconducting Compound followed by hellically
wrapped Copper Tape
5. Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
6. Armouring : Single layer of Aluminium Round Wire / Flat Strip
7. Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other color as per requirement
Electrical Parameters
Max. Conductor Approx. Conductor
Size D.C.Resistance at A.C.Resistance at Normal Current Rating Short Circuit Current
Reactance Capacitance Rating for 1 Second
(Cross 20 C 90 C
of Cable at of Cable Duration
Sectional
50 Hz (Approx.) For Aluminium Conductor For Copper Conductor
Area) Aluminium Copper Aluminium Copper (Approx.) Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
25 1.20 0.727 1.54 0.931 0.164 0.14 100 90 120 130 115 155 2.35 3.58
35 0.868 0.524 1.11 0.671 0.156 0.16 120 105 145 155 140 185 3.29 5.01
50 0.641 0.387 0.820 0.495 0.147 0.17 140 125 170 185 160 220 4.70 7.15
70 0.443 0.268 0.567 0.343 0.139 0.20 175 155 215 225 195 275 6.58 10.01
95 0.320 0.193 0.410 0.248 0.132 0.21 205 180 260 265 235 340 8.93 13.59
120 0.253 0.153 0.325 0.197 0.126 0.23 235 205 305 300 265 390 11.28 17.16
150 0.206 0.124 0.265 0.159 0.124 0.25 260 230 345 335 295 440 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.120 0.26 295 260 395 380 330 510 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.116 0.29 340 300 470 435 380 600 22.56 34.32
300 0.100 0.0601 0.130 0.0778 0.112 0.32 385 335 540 490 425 680 28.20 42.90
400 0.0778 0.0470 0.1023 0.0618 0.109 0.35 440 380 630 550 480 790 37.60 57.20
500 0.0605 0.0366 0.0808 0.0489 0.105 0.39 495 430 730 610 530 910 47.00 71.50
630 0.0469 0.0283 0.0648 0.0391 0.102 0.43 560 480 840 680 580 1030 59.22 90.10
800 0.0367 0.0221 0.0530 0.0319 0.097 0.50 620 530 960 740 630 1140 75.20 114.40
1000 0.0291 0.0176 0.0444 0.0268 0.096 0.56 680 580 1070 790 670 1250 94.00 143.00
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

46
LT/HT Power & Control Cables

Table - 34
TECHNICAL DETAILS FOR HAVELLS 11/11 KV
THREE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Physical Parameters Cable Code : A2XFY/2XFY, A2XWY/2XWY (11KV UNEARTHED GRADE)
Flat Strip Armoured (A2XFY/2XFY) Round Wire Armoured (A2XWaY/2XWaY)
Approx. Weight of Approx. Weight of
Size Nominal Minimum Nominal Minimum Approx. Cable Cable
Minimum Approx.
(Cross insulation Inner Armour Outer Overall Nominal dia
With Alm With Cu Outer Sheath Overall Dia With Alm With Cu
Sectional thickness Sheath Strip Sheath Dia of of armor wire
Cond. Cond. Thickness of Cable Cond. Cond.
Area) Thickness Dimension Thickness Cable
A2XFY 2XFY A2XWY 2XWY
Sqmm mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
25 5.50 0.50 4 X 0.80 1.88 48 2700 3050 2.50 2.04 51 3900 4200
35 5.50 0.50 4 X 0.80 2.04 50 3000 3500 2.50 2.20 54 4250 4700
50 5.50 0.60 4 X 0.80 2.20 53 3400 4100 2.50 2.20 57 4700 5400
70 5.50 0.60 4 X 0.80 2.20 57 3850 4900 2.50 2.36 61 5300 6300
95 5.50 0.60 4 X 0.80 2.36 61 4400 5900 3.15 2.52 66 6600 8000
120 5.50 0.70 4 X 0.80 2.52 65 4950 6850 3.15 2.52 69 7200 9050
150 5.50 0.70 4 X 0.80 2.52 68 5500 7850 3.15 2.68 72 7800 10150
185 5.50 0.70 4 X 0.80 2.68 71 6100 9100 3.15 2.84 76 8650 11550
240 5.50 0.70 4 X 0.80 2.84 76 7100 11050 3.15 3.00 81 9800 13700
300 5.50 0.70 4 X 0.80 3.00 81 8100 13100 4.00 3.00 88 12000 16900
400 5.50 0.70 4 X 0.80 3.00 88 9400 15800 4.00 3.00 95 13600 19900
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Cross-sectional view
Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
Conductor Screening : Extruded Semiconductor Compound
Insulation Material : XLPE (Cross linked polyethylene)
Insulation Screening : Extruded Semiconducting Compound followed by helically wrapped Copper Tape
Filler : PVC Filler
Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Armouring : Single layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other color as per requirement

Electrical Parameters
Max. Conductor Approx. Conductor
Size D.C.Resistance at A.C.Resistance at Reactance Normal Current Rating Short Circuit Current
Capacitance Rating for 1 Second
(Cross 20 C 90 C of Cable at
of Cable Duration
Sectional 50 Hz
(Approx.) For Aluminium Conductor For Copper Conductor
Area) Aluminium Copper Aluminium Copper (Approx.)
Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
25 1.20 0.727 1.54 0.931 0.145 0.14 95 82 105 120 105 135 2.35 3.58
35 0.868 0.524 1.11 0.671 0.138 0.16 115 97 125 145 125 165 3.29 5.01
50 0.641 0.387 0.820 0.495 0.129 0.17 130 115 150 170 150 195 4.70 7.15
70 0.443 0.268 0.567 0.343 0.124 0.20 160 140 190 210 180 240 6.58 10.01
95 0.320 0.193 0.410 0.248 0.116 0.21 190 165 230 250 215 295 8.93 13.59
120 0.253 0.153 0.325 0.197 0.112 0.23 220 190 260 280 240 335 11.28 17.16
150 0.206 0.124 0.265 0.159 0.108 0.25 245 210 295 310 270 380 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.105 0.26 275 240 335 350 305 430 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.102 0.29 315 275 395 400 350 500 22.56 34.32
300 0.100 0.0601 0.130 0.0778 0.0999 0.32 355 310 450 445 390 570 28.20 42.90
400 0.0778 0.0470 0.1023 0.0618 0.0954 0.35 400 350 520 500 440 650 37.60 57.20
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

47
LT/HT Power & Control Cables

Table - 35
TECHNICAL DETAILS FOR HAVELLS 12.7/22 KV
SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Physical Parameters Cable Code : A2XFaY/2XFaY, A2XWaY/2XWaY (22KV EARTHED GRADE)
Flat Strip Armoured (A2XFaY/2XFaY) Round Wire Armoured (A2XWaY/2XWaY)
Approx. Weight of Approx. Weight of
Size Nominal Minimum Nominal Minimum Approx. Cable Cable
(Cross insulation Inner Nominal dia Minimum Approx.
Armour Outer Overall With Alm With Cu With Alm With Cu
Sectional thickness Sheath of armor wire Outer Sheath Overall Dia
Strip Sheath Dia of Cond. Cond. Cond. Cond.
Area) Thickness Thickness of Cable
Dimension Thickness Cable A2XFaY 2XFaY A2XWaY 2XWaY
Sqmm mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
25 6.00 0.30 4 X 0.80 1.40 25 700 850 1.60 1.40 27 800 950
35 6.00 0.30 4 X 0.80 1.40 26 800 950 1.60 1.56 28 900 1100
50 6.00 0.30 4 X 0.80 1.56 28 900 1150 1.60 1.56 30 1000 1250
70 6.00 0.30 4 X 0.80 1.56 30 1000 1400 1.60 1.56 31 1100 1500
95 6.00 0.40 4 X 0.80 1.56 31 1150 1700 2.00 1.56 34 1350 1900
120 6.00 0.40 4 X 0.80 1.56 33 1300 1950 2.00 1.56 35 1500 2150
150 6.00 0.40 4 X 0.80 1.56 35 1400 2200 2.00 1.56 37 1600 2450
185 6.00 0.40 4 X 0.80 1.56 36 1550 2600 2.00 1.72 39 1800 2900
240 6.00 0.40 4 X 0.80 1.56 38 1800 3150 2.00 1.72 41 2050 3450
300 6.00 0.40 4 X 0.80 1.72 41 2100 3800 2.00 1.72 43 2300 4100
400 6.00 0.50 4 X 0.80 1.88 45 2500 4650 2.00 1.88 47 2750 5000
500 6.00 0.50 4 X 0.80 1.88 49 2950 5750 2.50 2.04 52 3400 6300
630 6.00 0.50 4 X 0.80 2.04 53 3500 7100 2.50 2.04 56 3950 7700
800 6.00 0.60 4 X 0.80 2.04 57 4200 8800 2.50 2.20 61 4750 9550
1000 6.00 0.60 4 X 0.80 2.20 61 4950 10750 2.50 2.36 65 5550 11550
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Cross-sectional view
1. Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
2. Conductor Screening : Extruded Semiconductor Compound
3. Insulation Material : XLPE (Cross linked polyethylene)
4. Insulation Screening : Extruded Semiconducting Compound followed by hellically
wrapped Copper Tape
5. Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
6. Armouring : Single layer of Aluminium Round Wire / Flat Strip
7. Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other color as per requirement
Electrical Parameters
Max. Conductor Approx. Conductor
Size D.C.Resistance at A.C.Resistance at Normal Current Rating Short Circuit Current
Reactance Capacitance Rating for 1 Second
(Cross 20 C 90 C
of Cable at of Cable Duration
Sectional
50 Hz (Approx.) For Aluminium Conductor For Copper Conductor
Area) Aluminium Copper Aluminium Copper (Approx.) Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
25 1.20 0.727 1.54 0.931 0.166 0.13 100 90 120 130 115 155 2.35 3.58
35 0.868 0.524 1.11 0.671 0.158 0.15 120 105 145 155 135 185 3.29 5.01
50 0.641 0.387 0.820 0.495 0.149 0.16 140 120 175 180 155 225 4.70 7.15
70 0.443 0.268 0.567 0.343 0.140 0.18 170 150 220 215 190 280 6.58 10.01
95 0.320 0.193 0.410 0.248 0.134 0.20 200 175 265 255 220 335 8.93 13.59
120 0.253 0.153 0.325 0.197 0.130 0.22 225 195 300 285 245 380 11.28 17.16
150 0.206 0.124 0.265 0.159 0.126 0.23 250 215 340 310 270 430 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.122 0.25 280 240 385 345 300 485 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.118 0.27 315 275 450 390 335 560 22.56 34.32
300 0.100 0.0601 0.130 0.0778 0.113 0.30 345 300 500 420 360 620 28.20 42.90
400 0.0778 0.0470 0.1023 0.0618 0.110 0.32 385 330 570 455 395 690 37.60 57.20
500 0.0605 0.0366 0.0808 0.0489 0.107 0.36 415 360 640 480 415 750 47.00 71.50
630 0.0469 0.0283 0.0648 0.0391 0.103 0.40 450 385 720 510 440 820 59.22 90.10
800 0.0367 0.0221 0.0530 0.0319 0.0997 0.46 485 415 790 540 460 840 75.20 114.40
1000 0.0291 0.0176 0.0444 0.0268 0.0970 0.52 510 435 850 550 475 940 94.00 143.00
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

48
LT/HT Power & Control Cables

Table - 36
TECHNICAL DETAILS FOR HAVELLS 12.7/22 KV
THREE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Physical Parameters Cable Code : A2XFY/2XFY, A2XWY/2XWY (22KV EARTHED GRADE)
Flat Strip Armoured (A2XFY/2XFY) Round Wire Armoured (A2XWaY/2XWaY)
Approx. Weight of Approx. Weight of
Size Nominal Minimum Nominal Minimum Approx. Cable Minimum Approx. Cable
(Cross insulation Inner Nominal dia
Armour Outer Overall With Alm With Cu Outer Sheath Overall Dia With Alm With Cu
Sectional thickness Sheath of armor wire
Strip Sheath Dia of Cond. Cond. Thickness of Cable Cond. Cond.
Area) Thickness Dimension Thickness Cable A2XFY 2XFY A2XWY 2XWY
Sqmm mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
25 6.00 0.50 4 X 0.80 2.04 50 2900 3250 2.50 2.20 54 4200 4500
35 6.00 0.60 4 X 0.80 2.04 52 3200 3750 2.50 2.20 56 4600 5050
50 6.00 0.60 4 X 0.80 2.20 56 3350 4350 2.50 2.36 60 5050 5700
70 6.00 0.60 4 X 0.80 2.36 59 3850 5200 2.50 2.36 63 5600 6600
95 6.00 0.60 4 X 0.80 2.36 63 4700 6150 3.15 2.52 68 7000 8350
120 6.00 0.70 4 X 0.80 2.52 66 5250 7150 3.15 2.68 71 7550 9400
150 6.00 0.70 4 X 0.80 2.68 70 5800 8150 3.15 2.68 75 8200 10500
185 6.00 0.70 4 X 0.80 2.68 73 6400 9400 3.15 2.84 79 9100 11950
240 6.00 0.70 4 X 0.80 2.84 78 7400 11400 4.00 3.00 85 11350 15200
300 6.00 0.70 4 X 0.80 3.00 83 8350 13350 4.00 3.00 90 12350 17250
400 6.00 0.70 4 X 0.80 3.00 90 9700 16150 4.00 3.00 97 14100 20400
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Cross-sectional view

Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
Conductor Screening : Extruded Semiconductor Compound
Insulation Material : XLPE (Cross linked polyethylene)
Insulation Screening : Extruded Semiconducting Compound followed by helically wrapped Copper Tape
Filler : PVC Filler
Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Armouring : Single layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other color as per requirement

Electrical Parameters
Max. Conductor Approx. Conductor
Size D.C.Resistance at A.C.Resistance at Reactance Normal Current Rating Short Circuit Current
Capacitance Rating for 1 Second
(Cross 20 C 90 C of Cable at
of Cable Duration
Sectional 50 Hz
(Approx.) For Aluminium Conductor For Copper Conductor
Area) Aluminium Copper Aluminium Copper (Approx.)
Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
25 1.20 0.727 1.54 0.931 0.148 0.13 90 85 110 120 100 135 2.35 3.58
35 0.868 0.524 1.11 0.671 0.141 0.15 110 100 130 145 120 165 3.29 5.01
50 0.641 0.387 0.820 0.495 0.132 0.16 130 115 155 170 150 200 4.70 7.15
70 0.443 0.268 0.567 0.343 0.125 0.18 160 140 190 205 180 245 6.58 10.01
95 0.320 0.193 0.410 0.248 0.119 0.20 190 170 230 245 215 300 8.93 13.59
120 0.253 0.153 0.325 0.197 0.114 0.22 215 190 265 275 245 340 11.28 17.16
150 0.206 0.124 0.265 0.159 0.111 0.23 240 215 300 305 275 385 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.107 0.25 270 240 340 345 305 435 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.104 0.27 310 275 400 395 350 510 22.56 34.32
300 0.100 0.0601 0.130 0.0778 0.102 0.30 350 310 455 440 390 580 28.20 42.90
400 0.0778 0.0470 0.1023 0.0618 0.097 0.32 395 355 530 495 440 660 37.60 57.20
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

49
LT/HT Power & Control Cables

Table - 37
TECHNICAL DETAILS FOR HAVELLS 19/33 KV
SINGLE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Physical Parameters Cable Code : A2XFaY/2XFaY, A2XWaY/2XWaY (33KV EARTHED GRADE)
Flat Strip Armoured (A2XFaY/2XFaY) Round Wire Armoured (A2XWaY/2XWaY)
Approx. Weight of Approx. Weight of
Size Nominal Minimum Nominal Minimum Approx. Cable Cable
(Cross insulation Inner Nominal dia Minimum Approx.
Armour Outer Overall With Alm With Cu With Alm With Cu
Sectional thickness Sheath of armor wire Outer Sheath Overall Dia
Strip Sheath Dia of Cond. Cond. Cond. Cond.
Area) Thickness Thickness of Cable
Dimension Thickness Cable A2XFaY 2XFaY A2XWaY 2XWaY
Sqmm mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
25 8.80 0.40 4 X 0.80 1.56 32 1050 1150 2.00 1.56 34 1250 1400
35 8.80 0.40 4 X 0.80 1.56 33 1150 1300 2.00 1.56 35 1350 1500
50 8.80 0.40 4 X 0.80 1.56 34 1200 1450 2.00 1.56 37 1450 1700
70 8.80 0.40 4 X 0.80 1.56 36 1350 1700 2.00 1.56 38 1550 1950
95 8.80 0.40 4 X 0.80 1.56 37 1500 2000 2.00 1.72 40 1750 2300
120 8.80 0.40 4 X 0.80 1.72 39 1650 2300 2.00 1.72 41 1900 2550
150 8.80 0.40 4 X 0.80 1.72 40 1800 2600 2.00 1.72 43 2050 2900
185 8.80 0.50 4 X 0.80 1.72 42 2000 3000 2.00 1.72 45 2300 3300
240 8.80 0.50 4 X 0.80 1.88 45 2300 3650 2.00 1.88 47 2550 3950
300 8.80 0.50 4 X 0.80 1.88 47 2550 4250 2.50 2.04 50 3000 4750
400 8.80 0.50 4 X 0.80 2.04 50 2950 5100 2.50 2.04 54 3400 5650
500 8.80 0.60 4 X 0.80 2.04 55 3500 6250 2.50 2.20 59 4050 6900
630 8.80 0.60 4 X 0.80 2.20 59 4100 7700 2.50 2.36 63 4700 8400
800 8.80 0.60 4 X 0.80 2.36 63 4850 9450 2.50 2.36 67 5400 10200
1000 8.80 0.70 4 X 0.80 2.36 67 5650 11400 3.15 2.52 72 6550 12550
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Cross-sectional view
1. Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
2. Conductor Screening : Extruded Semiconductor Compound
3. Insulation Material : XLPE (Cross linked polyethylene)
4. Insulation Screening : Extruded Semiconducting Compound followed by hellically wrapped Copper Tape
5. Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
6. Armouring : Single layer of Aluminium Round Wire / Flat Strip
7. Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour of Outer Sheath : Black or any other color as per requirement

Electrical Parameters
Max. Conductor Approx. Conductor
Size D.C.Resistance at A.C.Resistance at Normal Current Rating Short Circuit Current
Reactance Capacitance Rating for 1 Second
(Cross 20 C 90 C
of Cable at of Cable Duration
Sectional
50 Hz (Approx.) For Aluminium Conductor For Copper Conductor
Area) Aluminium Copper Aluminium Copper (Approx.) Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
25 1.20 0.727 1.54 0.931 0.175 0.10 100 90 120 130 115 155 2.35 3.58
35 0.868 0.524 1.11 0.671 0.169 0.11 120 105 145 155 135 185 3.29 5.01
50 0.641 0.387 0.820 0.495 0.161 0.12 140 120 175 180 155 225 4.70 7.15
70 0.443 0.268 0.567 0.343 0.152 0.14 170 150 220 215 190 280 6.58 10.01
95 0.320 0.193 0.410 0.248 0.145 0.15 200 175 265 255 220 335 8.93 13.59
120 0.253 0.153 0.325 0.197 0.140 0.16 225 195 300 285 245 380 11.28 17.16
150 0.206 0.124 0.265 0.159 0.135 0.18 250 215 340 310 270 430 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.130 0.19 280 240 385 345 300 485 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.126 0.21 315 275 450 390 335 560 22.56 34.32
300 0.100 0.0601 0.130 0.0778 0.122 0.23 345 300 500 420 360 620 28.20 42.90
400 0.0778 0.0470 0.1023 0.0618 0.117 0.25 385 330 570 455 395 690 37.60 57.20
500 0.0605 0.0366 0.0808 0.0489 0.113 0.27 415 360 640 480 415 750 47.00 71.50
630 0.0469 0.0283 0.0648 0.0391 0.111 0.29 450 385 720 510 440 820 59.22 90.10
800 0.0367 0.0221 0.0530 0.0319 0.105 0.34 485 415 790 540 460 840 75.20 114.40
1000 0.0291 0.0176 0.0444 0.0268 0.102 0.37 510 435 850 550 475 940 94.00 143.00
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

50
LT/HT Power & Control Cables

Table - 38
TECHNICAL DETAILS FOR HAVELLS 19/33 KV
THREE CORE, ALUMINIUM/COPPER CONDUCTOR, XLPE INSULATED, ARMOURED CABLES
Ref Specication : IS 7098 Part-2
Physical Parameters Cable Code : A2XFY/2XFY, A2XWY/2XWY (33KV EARTHED GRADE)
Flat Strip Armoured (A2XFY/2XFY) Round Wire Armoured (A2XWaY/2XWaY)
Approx. Weight of Approx. Weight of
Size Nominal Minimum Nominal Minimum Approx. Cable Minimum Approx. Cable
(Cross insulation Inner Nominal dia
Armour Outer Overall With Alm With Cu Outer Sheath Overall Dia With Alm With Cu
Sectional thickness Sheath of armor wire
Strip Sheath Dia of Cond. Cond. Thickness of Cable Cond. Cond.
Area) Thickness Dimension Thickness Cable A2XFY 2XFY A2XWY 2XWY
Sqmm mm mm mm mm mm Kg/Km Kg/Km mm mm mm Kg/Km Kg/Km
25 8.80 0.70 4 X 0.80 2.36 63 4350 4650 3.15 2.52 68 6600 6800
35 8.80 0.70 4 X 0.80 2.52 66 4750 5200 3.15 2.68 71 7050 7400
50 8.80 0.70 4 X 0.80 2.52 69 5150 5800 3.15 2.68 74 7550 8100
70 8.80 0.70 4 X 0.80 2.68 72 5700 6700 3.15 2.84 77 8250 9200
95 8.80 0.70 4 X 0.80 2.84 76 6350 7800 3.15 3.00 81 9050 10450
120 8.80 0.70 4 X 0.80 2.84 79 6900 8700 4.00 3.00 86 10800 12500
150 8.80 0.70 4 X 0.80 3.00 83 7550 9850 4.00 3.00 89 11550 13750
185 8.80 0.70 4 X 0.80 3.00 86 9000 11100 4.00 3.00 93 12300 15100
240 8.80 0.70 4 X 0.80 3.00 91 9100 13000 4.00 3.00 97 13500 17250
300 8.80 0.70 4 X 0.80 3.00 96 10100 15050 4.00 3.00 102 14700 19550
400 8.80 0.70 4 X 0.80 3.00 103 11600 17950 4.00 3.00 109 16400 22600
* Tabulated Approx. Weight of Cable are only for the purpose of guideline for transportation, loading & unloading purpose.

Cross-sectional view

Conductor : Stranded Compacted Circular Aluminum / Copper as per Class-2 of IS: 8130
Conductor Screening : Extruded Semiconductor Compound
Insulation Material : XLPE (Cross linked polyethylene)
Insulation Screening : Extruded Semiconducting Compound followed by helically wrapped Copper Tape
Filler : PVC Filler
Inner Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Armouring : Single layer of Galvanized Steel Round Wire / Flat Strip
Outer Sheath : Extruded PVC Type ST-2 as per IS: 5831; Options : PVC Type ST-2/FR Type/FRLS Type
Colour Of Outer Sheath: Black. Options: Any Other Colours As Per Requirement

Electrical Parameters
Max. Conductor Approx. Conductor
Size D.C.Resistance at A.C.Resistance at Reactance Normal Current Rating Short Circuit Current
Capacitance Rating for 1 Second
(Cross 20 C 90 C of Cable at
of Cable Duration
Sectional 50 Hz
(Approx.) For Aluminium Conductor For Copper Conductor
Area) Aluminium Copper Aluminium Copper (Approx.)
Ground Duct Air Ground Duct Air Aluminium Copper
Sqmm Ohm/Km Ohm/Km Ohm/Km Ohm/Km Ohm/Km F/Km Amps Amps Amps Amps Amps Amps K.amps K.amps
25 1.20 0.727 1.54 0.931 0.160 0.10 90 85 110 120 100 135 2.35 3.58
35 0.868 0.524 1.11 0.671 0.153 0.11 110 100 130 145 120 165 3.29 5.01
50 0.641 0.387 0.820 0.495 0.146 0.12 130 115 155 170 150 200 4.70 7.15
70 0.443 0.268 0.567 0.343 0.138 0.14 160 140 190 205 180 245 6.58 10.01
95 0.320 0.193 0.410 0.248 0.130 0.15 190 170 230 245 215 300 8.93 13.59
120 0.253 0.153 0.325 0.197 0.125 0.16 215 190 265 275 245 340 11.28 17.16
150 0.206 0.124 0.265 0.159 0.122 0.18 240 215 300 305 275 385 14.10 21.45
185 0.164 0.0991 0.211 0.127 0.118 0.19 270 240 340 345 305 435 17.39 26.46
240 0.125 0.0754 0.162 0.0976 0.113 0.21 310 275 400 395 350 510 22.56 34.32
300 0.100 0.0601 0.130 0.0778 0.111 0.23 350 310 455 440 390 580 28.20 42.90
400 0.0778 0.0470 0.1023 0.0618 0.106 0.25 395 355 530 495 440 660 37.60 57.20
Note: Normal current ratings are given in standard conditions (as given in page no 52, 53), if site conditions are different, current rating should be multiplied by
rating factor as given in page no. 52 - 54

51
BASIC ASSUMPTION FOR CURRENT RATINGS & RATING FACTORS
SCOPE
The current ratings of cables as indicated in various tables have been calculated on certain assumed conditions.
In actual practice these conditions may be different. Therefore to determine the actual current ratings as per installation conditions, the tabulated
ratings shall be multiplied with appropriate factors
a) Basic assumption for current ratings
I) Maximum permissible temperature - 90C for XLPE insulation, 70C for general purpose PVC, 85C for HR PVC
ii) Ground/Duct temperature - 30C
iii) Ambient temperature - 40C
iv) Thermal resistivity of soil - 150C cm/W
v) Thermal resistivity of Dielectric 650C cm/W for PVC, 350C cm/W for XLPE
vi) Single core cables installed in one circuit in following arrangement Voltage Grade Depth of Laying
OR
vi) Multicore cables installed in single circuit 1.1KV cables 750mm
3.3KV to 11KV 900mm

b) Rating Factors More than 11KV 1050mm


i) Rating factors related to variation in ambient air temperature
Air Temperature in Deg. 20 25 30 35 40 45 50 55
Normal PVC 1.32 1.25 1.16 1.09 1.00 0.90 0.80 0.80
Rating factors HR PVC 1.22 1.17 1.12 1.06 1.00 0.94 0.87 0.80
XLPE 1.20 1.16 1.11 1.06 1.00 0.95 0..88 0.82

ii) Rating factors related to variation in ground temperature

Air Temperature in Deg. 15 20 25 30 35 40 45 50


Normal PVC 1.17 1.12 1.06 1.00 0.94 0.87 0.79 0.71
Rating factors HR PVC 1.13 1.09 1.04 1.00 0.95 0.90 0.85 0.80
XLPE 1.12 1.08 1.04 1.00 0.96 0.91 0..87 0.82

iii) Rating factors related to variation in ground thermal resistivity of soil for 3 single core cables laid direct in ground. (Average value)

Thermal Res. in oC.Cm/W 100 120 150 200 250 300


Rating factors 1.20 1.10 1.00 0.90 0.81 0.74

iv) Rating factors related to variation in ground thermal resistivity of soil for multi core cables laid direct in ground. (Average value)
Thermal Res. in oC.Cm/W 100 120 150 200 250 300
Rating factors 1.16 1.08 1.00 0.90 0.82 0.76

v) Rating factors related to variation in depth of laying for 1.1kv cables


1. For cross-sectional area of conductor < 25sqmm
Depth of laying (cm) > 75 90 105 120 150 180 & Above
Rating factors 1.00 0.99 0.98 0.97 0.96 0.95

2. For cross-sectional area of conductor 25 to 300sqmm


Depth of laying (cm) > 75 90 105 120 150 180 & Above
Rating factors 1.00 0.98 0.97 0.96 0.94 0.93

3. For cross-sectional area of conductor above 300sqmm


Depth of laying (cm) > 75 90 105 120 150 180 & Above
Rating factors 1.00 0.97 0.96 0.95 0.92 0.91

vi) Rating factors related to variation in depth of laying for 3.3kv to 11kv cables

Depth of laying (cm) > 75 90 105 120 150 180 & Above
Rating factors - 1.00 0.99 0.98 0.96 0.95

vii) Rating factors related to variation in depth of laying for above 11kv cables

Depth of laying (cm) > 75 90 105 120 150 180 & Above
Rating factors - - 1.00 0.99 0.98 0.96

52
BASIC ASSUMPTION FOR CURRENT RATINGS & RATING FACTORS
Group Rating Factors
1. Cable laid direct in Ground
No of cables/
Multicore cables in horizontal formation Single cables in horizontal formation
circuits in groups
Touching S=15CM S=30CM S=45CM S=60CM Touching S=15CM S=30CM S=45CM S=60CM
2 0.80 0.84 0.87 0.90 0.91 0.80 0.85 0.90 0.92 0.95
3 0.68 0.74 0.79 0.83 0.86 0.70 0.78 0.85 0.88 0.91
4 0.62 0.69 0.75 0.80 0.83 0.64 0.73 0.81 0.86 0.89
5 0.58 0.65 0.72 0.77 0.80 0.59 0.70 0.79 0.84 0.88
6 0.55 0.62 0.69 0.75 0.78 0.55 0.67 0.77 0.83 0.87
7 0.52 0.59 0.67 0.73 0.77 0.53 0.65 0.76 0.82 0.86
8 0.50 0.57 0.66 0.72 0.75 0.51 0.64 0.76 0.82 0.86
9 0.48 0.55 0.65 0.71 0.75 0.49 0.63 0.74 0.81 0.85
10 0.46 0.54 0.64 0.70 0.74 0.48 0.63 0.74 0.81 0.85
11 0.45 0.53 0.63 0.70 0.74 0.47 0.62 0.73 0.80 0.84
12 0.44 0.52 0.62 0.69 0.73 0.46 0.61 0.73 0.80 0.84

S = axial spacing of cable


No. of cables/
No. of Tier Multicore cables in Tier formation
circuits in groups
Touching S=15CM S=30CM S=45CM S=60CM
2 1 0.80 0.84 0.87 0.90 0.91
3 1 0.68 0.74 0.79 0.83 0.86
4 2 0.60 0.66 0.73 0.77 0.79
5 2 0.55 0.61 0.68 0.71 0.73
6 2 0.51 0.57 0.63 0.67 0.69
7 3 0.48 0.54 0.59 0.63 0.64
8 3 0.46 0.51 0.56 0.60 0.61
9 3 0.44 0.48 0.53 0.57 0.58
10 4 0.42 0.47 0.52 0.55 0.56
11 4 0.41 0.46 0.50 0.54 0.55
12 4 0.40 0.45 0.49 0.53 0.54
2. Cable laid direct in open racks in air
(i) Multicore Cables in open racks in air

No. of racks

No. of racks No. of cables per rack No. of cables per rack
1 2 3 6 9 1 2 3 6 9
1 1.00 0.98 0.96 0.93 0.92 1.00 0.84 0.80 0.75 0.73
2 1.00 0.95 0.93 0.90 0.89 1.00 0.80 0.76 0.71 0.69
3 1.00 0.94 0.92 0.89 0.88 1.00 0.78 0.74 0.70 0.68
6 1.00 0.93 0.90 0.87 0.86 1.00 0.76 0.72 0.65 0.66

(ii) Single Core Cables In open racks In air

No. of Racks No. of Circuit Racks (3 single cores) per rack


1 2 6
1 1 0.98 0.96
2 1 0.95 0.93
3 1 0.94 0.92
4 1 0.93 0.9

53
S = axial spacing of cable
No. of cables/
No. of Tier Multicore cables in Tier formation
circuits in groups
Touching S=15CM S=30CM S=45CM S=60CM
2 1 0.80 0.84 0.87 0.90 0.91
3 1 0.68 0.74 0.79 0.83 0.86
4 2 0.60 0.66 0.73 0.77 0.79
5 2 0.55 0.61 0.68 0.71 0.73
6 2 0.51 0.57 0.63 0.67 0.69
7 3 0.48 0.54 0.59 0.63 0.64
8 3 0.46 0.51 0.56 0.6 0.61
9 3 0.44 0.48 0.53 0.57 0.58
10 4 0.42 0.47 0.52 0.55 0.56
11 4 0.41 0.46 0.50 0.54 0.55
12 4 0.40 0.45 0.49 0.53 0.54
Multicore cables (spacing of cable S/core cables in trefoil touching formation
No. of cables/ Multicore cable (Touching)
equal to dia meter of cable No of spacing between circuits equal to twice the
circuits in groups No of cables in racks
cables in racks diameter of cable) No of cables in racks
1 2 3 4 1 2 3 4 1 2 3 4
1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
2 0.84 0.80 0.78 0.76 0.98 0.95 0.94 0.93 0.98 0.95 0.94 0.93
3 0.80 0.76 0.74 0.72 0.96 0.93 0.92 0.90 0.96 0.93 0.92 0.90
4 0.76 0.71 0.70 0.68 0.93 0.90 0.89 0.87

Estimated Voltage Drops * Selection criteria of MV/HV


in PVC/XLPE Aluminium Cables For cable size for primary distribution
A.C. System SCOPE
The conductor size in the cables for any installation is also governed by its ability to carry short circuit current of system.
(Voltage drop - Volts/Km/Amps)
For L.V. distribution cable may be selected on the basis of continuous load current. But in case of MV/HV distribution it is
Nominal always safer to select the cable on the basis of ability of conductor to carry expected short circuit current. Short circuit
area of current rating of cable should in line with short circuit capacity of damping apparatus such as circuit breakers, Transformers
P.V.C. Cable XLPE Cable
conductor & reactor etc. beside its capacity to carry desired load current. Short circuit ratings of cables each size are given in relevant
(sq. mm) tables & have been calculated on the basis of IEC-949 & IEC-986 & on the following assumption
Single Three Single Three
a) Temperature of conductor just prior to short circuit
Phase Phase Phase System
i) With XLPE insulation - 90 Deg. C ii) With PVC insulation - 70 Deg. C
1.5 43.44 37.62 46.34 40.13
b) Maximum permissible conductor temperature during short circuit
2.5 29.04 25.15 30.98 26.83
i) With XLPE insulation - 250 Deg. C ii) With PVC insulation - 160 Deg. C
4 17.78 15.40 18.98 16.44
6 11.06 9.58 11.80 10.22 c) Volumetric specic heat of the conductor
i) With Aluminium conductor - 2.5 x 10-3J/Deg. C/MM3
10 7.40 6.41 7.88 6.82
ii) With Copper conductor - 3.45 x 10-3J/Deg. C/MM3
16 4.58 3.97 4.90 4.24 d) Reciprocal of temperature co-efcient of resistance at 9 Deg. C
25 2.89 2.50 3.08 2.67 i) With Aluminium conductor - 228 ii) With Copper conductor - 234.5
35 2.10 1.80 2.23 1.94 Short circuit current rating at different duration may be calculated as
50 1.55 1.30 1.65 1.44 Ish (for t duration) = Ish (for 1Sec.) Ish for 1 Sec. Duration is given in relevant tables in KA
70 1.10 0.94 1.15 1.00 t t = Time duration required tobe calculated of short circuit in Sec.
95 0.79 0.68 0.83 0.70 SELECTION CRITERIA OF H.V./MV CABLES FOR PRIMARY DISTRIBUTION
120 0.63 0.55 0.66 0.56 REQUIRED DATAS FOR EXAMPLE
150 0.52 0.46 0.55 0.48 1) Nominal System voltage at H.T. Side 11KV
185 0.42 0.37 0.44 0.40 2) Short circuit level for H.T. system 25KA
240 0.34 0.30 0.35 0.30 3) Fault withstand time for H.T. CBs 0.5 SEC
300 0.28 0.26 0.30 0.26 4) Formula for calculating H.T. cable size
With Aluiminium cond./XLPE insulated cable = Ish X t = 25 X0.5
400 0.24 0.22 0.24 0.22
0.094 0.094
500 0.23 0.20 0.23 0.20 = 188
630 0.20 0.18 0.21 0.18
800 0.19 - 0.20 - Hence nearest higher size 240sqmm is required
1000 0.18 - 0.18 - With Copper cond./XLPE insulated cable = Ish X t = 25 X 0.5
**Above voltage drops (volts/km/amps) shall be multiplied 0.143 0.143
with rated current & length of Cable in K.M. to calculate = 124
total voltage drop in particular length and size of cables. Hence nearest higher size 150 sqmm is required

ELECTRICAL FORMULAS FOR CALCULATING A.C. LOAD CURRENT


for Single phase (A.C.) for Three phase (A.C.)
Load current in Amps when KVA is given KVA X1000 KVA X1000
V 1.732 X V
for Single phase (A.C.) for Three phase (A.C.)
Load current in Amps when Kilo Watt is given KW X1000 KW X1000
VXpf 1.732 X V X pf
for Single phase (A.C.) for Three phase (A.C.)
Load current in Amps when H.P. is given H.P. X746 H.P. X746
V X %EFf X pf 1.732 X V X %Eff X pf
V = Nominal system voltage in Volts, pf = Power factor, KVA = Kilo Volts Ampere, H.P. = Horse Power

54
Standard drum lengths of cables
STANDARD LENGTH (MTS) WITH 5% TOLERANCE
DESCRIPTION OF CABLE UN-AR-
STRIP ARMOURED ROUND WIRE ARMOURED
MOURED

1.1KV PVC/XLPE CABLES


WITH ALUMINIUM

UP TO 150SQMM-1000 UP TO 150SQMM-1000 UP TO 150SQMM-1000


~ SINGLE CORE
185 TO 1000sqmm-500 185 to 1000sqmm-500 185 to 1000sqmm-500

UP TO 50SQMM-1000, 70 TO
UP TO 50SQMM-1000 UP TO 50SQMM-1000
~ TWO CORE 500sqmm
70 to 630sqmm-500 70 to 630sqmm-500
500, 630sqmm-250

UP TO 50SQMM-1000 UP TO 50SQMM-1000, 70 TO
UP TO 50SQMM-1000
~ THREE CORE 70 to 500sqmm-500 300sqmm
70 to 630sqmm-500
630sqmm-250 500, 500 to 630sqmm-250

UP TO 50SQMM-1000 UP TO 50SQMM-1000, 70 TO
UP TO 50SQMM-1000
~ THREE & HALF CORE 70 to 400sqmm-500 300sqmm
70 to 630sqmm-500
500 to 630sqmm-250 500, 400-630sqmm-250

UP TO 50SQMM-1000 UP TO 50SQMM-1000 UP TO 50SQMM-1000, 70 to


FOUR CORE 70 to 500sqmm-500 70 to 400sqmm-500 240sqmm
630sqmm-250 500 to 630sqmm-250 500, 300 to 630sqmm-250

1.1KV PVC/XLPE CABLES


WITH COPPER CONDUCTOR

UP TO 150SQMM-1000 UP TO 150SQMM-1000 UP TO 150SQMM-1000


~ SINGLE CORE 185 TO 630sqmm-500 185 to 630sqmm-500 185 to 630sqmm-500
800 to 1000sqmm-250 800 to 1000sqmm-250 800 to 1000sqmm-250

UP TO 10SQMM-1000 UP TO 10SQMM-1000 UP TO 10SQMM-1000, 70 TO


~ TWO CORE 16 to 300sqmm-500 16 to 300sqmm-500 500sqmm 500,
400 to 630sqmm-250 400 to 630sqmm-250 500, 300 to 630sqmm-250

UP TO 10SQMM-1000, 16 TO
UP TO 10SQMM-1000
UP TO 10SQMM-1000 185sqmm
~ THREE CORE 16 to 240sqmm-500
300 to 400sqmm-250 16 to 185sqmm-500
240sqmm-400sqmm-250
500, 240 to 400sqmm-250

UP TO 10SQMM-1000, 16 TO
UP TO 10SQMM-1000
UP TO 10SQMM-1000 150sqmm
~ THREE & HALF CORE 16 to 240sqmm-500
300 to 400sqmm-250 16 to 185sqmm-500
240 to 400sqmm-250
500, 185 to 400sqmm-250

UP TO 10SQMM-1000 UP TO 10SQMM-1000 UP TO 10SQMM-1000, 16 to


FOUR CORE 16 to 240sqmm-500 16 to 150sqmm-500 150sqmm
300 to 400sqmm-250 240 to 400sqmm-250 500, 185 to 400sqmm-250

- Control cables more than FOUR CORES shall be supplied in 500 mts length

DESCRPITON OF CABLE 6.35/11KV GRADE 1/11KV GRADE 19/33KV GRADE

H.T. XLPE CABLES WITH ALUMINIUM CONDUCTOR

UP TO 150SQMM-1000 UP TO 150SQMM-1000 UP TO 150SQMM-1000


~ SINGLE CORE-A2XWaY
185 to 1000sqmm-500 185 to 1000sqmm-500 185 to 1000sqmm-500

25 TO 300SQMM-500 25 TO 185SQMM-500 25 TO 95SQMM-500


~ THREE CORE-A2XFY
400sqmm-250 240 to 400sqmm-250 120 to 400sqmm-250

25 TO 150SQMM-500 25 TO 95SQMM-500 25 TO 50SQMM-250


~ THREE CORE-A2XWY 185 to 300sqmm-250 120 to 240sqmm-250 70 to 120sqmm-250
400sqmm-200 300 to 400sqmm-200 185 to 400sqmm-200

55
Quality Control
It has been rightly said that Quality is never an accident, it is Test
always the result of intelligent efforts.
The tests on cables have been classied broadly in four categories
In the manufacture of cables, intelligent efforts are incorporated
to achieve quality. For a quality end products, control starts from as follows:
proper design of the product. All raw materials are selected Routine Tests:
carefully and only materials of high quality are used in production.
Having done this, stage wise inspection is done to ensure Tests carried out on each cable to check the requirements which
conformity with the requirements of relevant Indian Standards are likely to vary during production.
where these apply.
Type Tests:
Stage - Wise Inspection
Tests carried out to prove conformity with the specication.
i) Wire-Drawing : Wire diameter
Surface These are intended to prove the general qualities and design of a
Shape given type of cable.
Quality of joints in the wire
Acceptance Tests:
ii) Stranding of Wires: : Quality of joints in the wires Tests carried out on samples taken from a lot for the purpose of
Compaction of conductor acceptance of the lot.
Shape of Conductor
Dimensions Optional Tests:
Resistance of Conductor
Special tests to be carried out when required by agreement
iii) Insulation : : Dimension over Insulation, between the purchaser and the manufacturer.
Thickness of Insulation,
Special tests required for FRLS Cables can also be carried out at
iv) Curing : Hot set test, Tensile strength & our works i.e. Halogen gas generation test to IEC - 754 Part - I,
(for XLPE Insulation) elongation test. Smoke generation test to ASTMD 2843, Oxygen index test and
Temperature index test to ASTMD - 2863, Flammability test to (1)
v) Screening : Dimension over screen, thick of IEC-332-1, (2) Swedish Chimney test to SS-4241475 Class F3 &
(for H.T. Screened cables) screen visual examination of (3) IEC-332-3, Flame resistance test to IEEE-383.
surface/defects.
Together with the most advanced equipment available, we are
v) Laying Up : Sequence of Cores able to offer to our valued customers assurances of highest
Direction of lay quality and strict adherence to the required specication. As a
Diameter over laid up cores third party guarantee, our cables have passed rigorous tests at
Circularity
various Government recogonized test laboratories such as CPRI,
vi) Inner Sheath : Thickness of Sheath Shri Ram Test House, ERDA Baroda, National Test House, ERTL,
Diameter over Sheath RTC.
Surface Uniformity
Routine Tests, Type Tests, Acceptance Tests and Optional Tests
Circularity
Porosity as per the Indian Standard Specication for Power and Control
Cables with PVC insulation, Cross linked Polyethylene insulation
vii) Armouring : Diameter of Wires/ and Special Tests are given in the Annexure.
Dimensions of Strips
Direction of lay
Coverage
Quality of Joints of Wires
Tensile Testing Machine
viii) Outer Sheath : Thickness of Sheath Diameter
over Sheath Tightness of Sheath
Eccentricity Porosity, Embossing

RM Testing Lab

56
Selection Guide
List of Tests as per IS:1554(Part - I): 1988, IS:1554 For selection of a cable, a rst hand knowledge of the system
(Part- II):1988, IS:7098 (Part - I):1988 and IS:7098 in which the cable is to be used, and the installation conditions
(Part-II) : 1985 under which the cable has to operate, is necessary. A knowledge
of statutory restrictions and the manufacturing facilities available
1. Routine Tests: in the country will help in nding out as to what type of cable will
a) Conductor Resistance Test be available for particular usage. The environmental conditions
b) High Voltage Test under which the cable has to operate will decide its protective
c) Armour Resistance Test for mining Type Cables covering. Thus once voltage grade of the cable, number of cores,
d) Partial Discharge test (for H.T. Screened cable) conductor material, type of insulation and protective coverings
are known, size of conductor remains to be decided. The rst
2. Type Tests: and foremost criteria for the size of conductor is continuous
a) Tensile Test (for Aluminium Conductor) current rating for the present load. There after the same should
b) Wrapping Test (for Aluminium Conductor) be checked for short circuit, voltage drop, over load capacities
c) Annealing Test (for Copper Conductor) and future expansions. Once decided the selection of next higher
d) Conductor Resistance Test size compared to what is essential for the requirement, will always
e) Test for Armour Wires/Strips be worthwhile.
f) Test for thickness of Insulation & Sheath
g) Physical Test for Insulation & Outer Sheath
Economic considerations are also necessary.
h) Insulation Resistance Test
i) High Voltage Test
j) Flammability Test INFORMATION REQUIRED WITH ENQUIRY & ORDER
k) Hot Set Test - (For XLPE Insulation only) The following information should be included in an enquiry:
l) Partial Discharge test (for H.T. Screened cable)
i) Voltage Grade.
m) Bending test (for H.T. Screened cable)
n) Dielectric Power factor test (for H.T. Screened cable ii) Whether cable is to be used on Earthed or Unearthed
with rated voltage 6.35/11KV & above) system (for voltages above 3.3 KV).
o) Heating cycle test (for H.T. Screened cable) iii) Type of installation whether in air or in ducts or in ground.
p) Impulse withstand test (for H.T. Screened cable) iv) If cables are grouped together, then number of cables in
group and vertical and horizontal spacing between them.
3 Acceptance Tests: v) Required value and duration of short circuit current.
a) Tensile Test (For Aluminium Conductor)
b) Wrapping Test (For Aluminium Conductor) Following further informations are also required for offering the
c) Annealing Test (For Copper Conductor) exact type of cable for any specic purpose:
d) Conductor Resistance Test a) The normal ambient or operating temperature.
e) Test for thickness of Insulation & Sheath b) The maximum temperature to which the PVC will be ex
f) High Voltage Test posed and the duration and frequency of such exposures.
g) Insulation Resistance Test
c) The material with which the PVC will be in contact i.e.
h) Tensile Strength & Elongation at break test for
oil, gases, acids, alkalies etc. at normal and maximum
Insulation and Sheath
temperature.
I) Hot Set Test - (for XLPE Insulation only)
j) Partial Discharge test (for H.T. Screened cable) d) If special ame retardent property is required.
e) If any special electrical characteristics needed.
4. Optional Tests:
a) Cold Bend Test
b) Cold Impact Test
c) Armour Resistance Test
(for other than Mining Type Cables)

5. Special Tests (As Applicable):


a) Oxygen Index Test as per ASTMD - 2863-77
b) Temp. Index Test as per ASTMD - 2863-77
c) Smoke Generation Test as per ASTMD - 2843-77
d) Acid Gas Generation Test as per IEC - 754-1
e) Flammability Test as per IEC - 332-1, IEEE-383,
SS-4241475 Class F3 and IEC - 332-3
g) Water absorption test (by Electrical Method)
h) Ultra voilet resistance to ASTM-G-53
i) Die electric Strength retention test
j) Test for Antirodent & Antitermite property

57
Handling & Storage
Handling (Unloading at site) : On receipt of cable drums visual inspection n case of multicore power cables, cables shall be laid side by side, with
of drums should be made ensuring drum packing is original. While spacings not less than one cable diameter. However derating factors for
unloading the cables certain precautions are to be taken to ensure the cables laid on trenches are to be referred.
safety of the cables. Multicore power cables and single core D.C. circuits may be clamped
1. The cable drums should not be dropped or thrown from rail way by means of galvanised mild steel saddles but 1.1 KV single core cables
wagons or trucks during unloading operations as the shock may should be clamped by means of non-magnetic saddles. The saddles
cause serious damage to cable layers. A crane should be used shall not be placed at intervals more than 1500 mm. for horizontal and
for unloading cable drums. When lifting drums with the crane, it is 1200 mm. for vertical runs.
3. Multicore control cables can be laid touching each other on cable
recommended that the lagging should be kept in place to prevent
racks and wherever required may be taken in two layers. They
the anges from curshing on to the cable. If the crane is not available,
should be clamped by means of PVC straps both for horizontal
a ramp should be prepared with approximate inclination of 1:3 or
and vertical runs (alternatively, fabricated aluminium clamps may be
1:4. The cable drum should be rolled over the ramp by means of
used) at regular intervals.
ropes and winches. Additionally a sand bed at the foot of the ramp 4. a) If the cables are buried directly in ground I.S. 1255 is to be followed
may be prepared to brake the rolling the cable drum. for code of practice. However, generally cables are laid 1000 mm.
2. Cable should not be dragged along the earth surface. below nished ground level at any point of cable run and 75 mm. of
3. Cable ends should always be sealed by means of suitable end sand cushioning to be provided.
sealing materials to prevant moisturisation of cores and armour. 4. b) In loose soil concrete pillar should be provided for as support and
4. Drums should be rolled in direction of arrow marked on the drum. hence pipes are recommended to the used for cable path.
5. If there is a possibility of mechanical damage, cables should be
Roll this way
Storage: protected by means of mild steel covers placed on racks.
Cables should be stored in a dry covered place to prevent exposure 6. While laying cables, special care to be taken at bends. Followings
to climatic conditions and wear and tear of wooden drums and it are the recommended bending radius for power and control cables.
should preferably on a concrete surface/rm surface which will not
cause the drums to sink and thus lead to ange rot and extreme PVC and XLPE Cables
Voltage Rating KV
difculty in moving the drums. Single Core Multi Core
All drums should be stored in such a manner as to leave sufcient Upto 1.1 Above 1.1 but upto 15 D 12 D
space between them for air circulation. It is desirable for drums to 11 K.V. 15 D 15 D
stand on battens placed directly under the anges. Above 11 K.V. 20 D 15 D
In no case should the drums be stored, On the Flat, i.e., with ange
horizontal. Where D is overall R
diameter of cable.

7. Maximum safe pulling force (when pulled by pulling eye) Aluminium


Laying: Conductor Cables : 3.0 Kg/mm2 Copper Conductor Cables : 5.0
For laying of cables special cares to be taken to prevent sharp bending, Kg/mm2 Proper method of pulling of cable should be used.
kinking, twisting. Cable should be unwound from drum by proper TESTING
mounting the cable drum on a cable wheel making sure the spindle INSULATION RESISTANCE MEASUREMENT OF CABLE
The voltage rating of I.R. Tester (Megger) should be chosen as following
is strong enough to carry the weight without bending and that it is
table :
lying horizontally in the bearings so as to prevent the drum creeping
to one side or the other while it is rotating. Rating of IR Rating of IR
Voltage grade Voltage grade
Tester (Megger) Tester
of cable of cable
of cable (Megger)
1.1 KV 500 V 11 KV 1000 V
Provision should be made to break the
drum to avoid further rolling & buckling
3.3 KV 1000 V 22 KV 2500 V
of cable during sudden stop. A simple 6.6 KV 1000 V 33 KV 2500 V
wooden plank can server this purpose
Testing during laying :
All new cables shall be megger-tested before jointing. After
This is incorrect way of pulling the cable & will Cable must be jointing is completed all LV Cables shall be megger-tested.
cause kinks & twist in cable. Shall be avoided at all puled from the top
End Terminations & Jointing :
Termination and jointing of Power & Control Cables shall be done
by means of compression methods using solderless tinned copper/
Aluminium terminal lugs. For control cables terminations, ring tongue or
reducer pin type terminal lug can also be used to suit the purpose.

Cable must be pulled accross hard & Overhead/Outdoor Termination


sharp objects to avoid the damage to ve
covering & insulation
XLPE insulation should be protected from direct solar rays or else ultra
Cable must be laid in ducts or trenches violet resistant sleeving / tapping must be provided on exposed XLPE
as shown in Fig. insulation at the Termination to avoid degradation / cracking due to direct
exposer of solar rays.
However, following salient points are to be considered during laying
procedure of cables laid in racks and in built-in trenches.
1. For laying of cables power cables to be placed at the bottom most
layer and control cables at top most layer.
2. Single core power cable for use on A.C. system shall be laid in delta
formation supported by non-magnetic material. Trefoil clamps of
suitable size are to be placed at regular intervals but preferably not
more than 800 mm. Axial spacing of two circuits in delta formation
shall not be less than 4 times the cable dia.
A view of dispatch yard

58
LIST OF MAJOR CUSTOMER
SECTOR -1 GOVERNMENT ORGANIZATION
S. No. Name of Customer S. No. Name of Customer
1 Engineers India Ltd 11 Department of Atomic Energy
2 NTPC 12 Airport Authority of India
3 NHPC 13 Electricity Department, UT Chandigarh
4 BHEL 14 NDMC
5 Power Grid Corporation of India Ltd. 15 EPIL
6 Steel Authority Of India 16 Electricity Department, Pondicherry
7 Eastern Railway, Fairlie Place, Kolkata 17 NTECL Vallor
8 Nuclear Power Corporation Ltd. 18 Aravali Power Corporation Ltd. (IGSTPP)
9 BEST Bombay 19 Durgapur Power Ltd.
10 Damodar Valley Corporation, kolkata

STATE ELECTRICITY BOARD


S. No. Name of Customer S. No. Name of Customer
1 Jaipur Vidhyut Vitran Nigam Limited 19 Uttarkhand Power Corporation Ltd.
2 Jodhpur Vidhyut Vitran Nigam Limited 20 MVVNL, Lucknow
3 Rajasthan Rajya Vidhyut Vitran Nigam Limited 21 PUVVNL , Varanasi
4 Ajmer Vidhyut Vitran Nigam Limited 22 PVVNL, Meerut
5 Kerela State Electricity Board 23 DVVNL, Agra
6 Madhya Pradesh State Electricity Board 24 CPDCL of AP ltd, Hyderabad
7 Gujrat Energy Transmission Corporation ltd. 25 APGENCO of AP ltd, Hyderabad
8 Uttar Gujrat Vij company ltd. 26 EPDCL of AP ltd, Vishakhapatnam
9 Dakshin Gujrat Vij company ltd. 27 NPDCL of AP ltd, Warangal
10 Paschim Gujrat Vij company ltd. 28 DPDCL of AP ltd, Triputi
11 Madhya Gujrat Vij company ltd. 29 WBSECL
12 Maharastra State electricity Distribution Corporation ltd. 30 North Delhi Power Limited, New Delhi
13 Maharastra State electricity Generation Corporation ltd. 31 CESC Limited
14 Maharastra State electricity Transmisssion Corpn. 32 TANGEDCO
15 Uttar Haryana Bijli Vitran Nigam, Ltd. 33 BSES Limited
16 Dakshin Haryana Bijli Vitran Nigam, Ltd. 34 HPSEB
17 BESCOM , Bangalore 35 NTECL , Chennai
18 Noida Power Corporation Ltd.

SECTOR - 2 OIL & GAS CORPORATION


S. No. Name of Customer S. No. Name of Customer
1 Indian Oil Corporation Ltd 10 MRPL , Mangalore
2 IOCL- PIPE LINE PROJECT 11 CPCL, Chennai
3 IOCL - REFINERY (8 Cities) 12 Boingaigaon Renery & Petro Ltd. Assam
4 Gas Authority of India Ltd. 13 Haldia Perto Chemicals
5 Bharat Petroleum Corporation Ltd. 14 Reliance Industries ltd.
6 Hindustan Petroleum Corporation Ltd. 15 Reliance Petroleum ltd.
7 Mittal Petroleum 16 Kochi Petroleum ltd.
8 Oil India Ltd. 17 ESSAR Oil
9 Numaligarh Renery Ltd.

SECTOR - 3 CEMENT
S. No. Name of Customer S. No. Name of Customer
1 ACC cement 7 Aditya birla Cement
2 Amrit Cement 8 Adhunik Cement
3 Vicat Sagar Cement 9 Mysore Cement
4 Raghuram Cement 10 L & T Cement
5 Ultratec Cement 11 Grasim Cement
6 JP Cement 12 Shree Cement, Beawar, Ajmer

59
SECTOR - 4 CORPORATE HOUSES
S. No. Name of Customer S. No. Name of Customer
1 Reliance Energy 8 JSW Steel
2 Jai Prakash Industries Ltd. , New Delhi 9 TATA Steel
3 Monenet Ispat & Energy Ltd. 10 VISA Steel
4 Grasim Industries Ltd. 11 INDUS BUILDWELL ltd.
5 Jindal Steel & Power 12 Schneider electric
6 BILT graphics paper products ltd. 13 Adani Group
7 Welspun, Mumbai

SECTOR - 5 PROMINENT EXPORT CUSTOMERS


S. No. Name of Customer S. No. Name of Customer
1 Ethio Cement, Ethiopia 11 Yangaon Transformers, Myanmar
2 Mohan Exports 12 UB Engineering, Dubai
3 Angelique International, 13 Kinyara Sugar, Uganda
4 Inter Trade Commercial services TANESCO, Tanzania 14 Silver Spring, Uganda
5 Afghan Solar, Afghanistan 15 Supereme Electricals, Kolkata (for Nigeria)
6 VEETEK Nigeria 16 Roongs & Rolling mills , Uganda
7 Nimra Jeddah Electric Est Saudi Arabia 17 Sameer Agriculture Kenya
8 True Liberty Electrical & Contracting Company, Kuwait 18 SESCO, Saudi Arabia
9 African Commodities Dubai (for Nigeria) 19 NIPP/PHCN, Nigeria
10 Duraplast INC, Liberia 20 Polygroup, Ghana

SECTOR - 6 EPC CONTRACTORS


S. No. Name of Customer S. No. Name of Customer
1 ABB Limited 7 Alstom - Power Automation Systems
2 Larsen & Toubro - ECC 8 ESSAR Projects
3 Siemens 9 Sterling & Willson
4 Mcnally Bharat 10 Punj Lloyd
5 Sudhir Power projects Ltd. 11 Areva T & D Ltd.
6 A 2 Z maintainence and constuctions 12 Thyssenkrupp, Pune

SECTOR - 7 FERTILIZER
S. No. Name of Customer S. No. Name of Customer
1 National Fertilizer Ltd. 4 IFFCO
2 ESSAR ( Fertilizer) 5 Kanpur Fertilizers
3 Matrix

60
Fire Survival Cables

Introduction
Need of ensuring safe operation of critical circuits is essential in todays installations. Normal cables
used in such installations render useless in re incidences. At Havells, your safety is our concern. Havells
has now developed special type Fire Survival Cables through research. These cables - also known as
CIRCUIT INTEGRITY CABLES & are designed to sustain the high temperatures for a dened minimum
period of time under direct re. These cables are useful to maintain their integrity during the dened period
of re. The construction of these cables is different if compared with ordinary cables. The conductor is
manufactured with a specially designed heat barrier and re resistant insulation which resists the re to
reach conductor surface. The cable continues to remain into operation at high temperatures like 650C,
750C and 950C as per various conditions of operation and applications.
Wires offering same properties are also available.
Specication
These cables are manufactured and tested in accordance with BS 7846, IS 7098(P-1), IEC 69331 and
BS 6387 for required temperatures and duration - depending upon the application of cable and site
conditions.
Constituents
HAVELLS FS CABLES are manufactured with the following materials.
1. Annealed Plain Copper Conductor
2. Heat Barrier Over the Conductor
3. Cross Linked Polyethylene
4. Galvanised Steel Armour
5. Zero Halogen & Low Smoke Compound
The ZHLS compound ascertains the least smoke and hence increased light transmission during burning
of cables. The circuit integrity of HAVELLS FS cables at high temperatures remains unaltered for the
required time period as per the specication dened.
Constructions

Conductor
made of high conductivity
annealed plain copper Heat Barrier
high temperature
Insulation sustaining tape
fire resistant cross
linked polyethylene Inner Sheath
Zero halogen &
low smoke compound
Armour
galvanised steel

Outer Sheath
Zero halogen &
low smoke compound

61
Solar Cables

Introduction
Solar photovoltaic industry gets more attention as the most promising environment- friendly industry, and it is expected to have the
signicant role in resolving the earths energy problem. As production costs diminish, users increasingly view these energy sources as
clean, cheap and reliable. In this background, the demand for SOLAR CABLE, which is the current transmission medium of solar energy
power generation, is expected to increase with the expansion of market.

Special Properties of Solar Cables


s Lifetime reliability: lasts up to 30 years even under tough external conditions.
s Outdoor durability: resists extreme temperatures (-40C to 120C maximum at the core) and ozone resistant.
s UV resistance: full protection against ultraviolet rays.
s Halogen-free: Low Smoke Emission & Low Toxicity/Corrosivity during re.
s Properties against re: ame retardant, re retardant.
s Flexibility and stripability: for fast and easy installation.
s Fully recyclable: in accordance with new environmental regulations.
s Easy installation with color identication (blue, red).
s Suitable to common connector types.
s 46CERTIlED

Constituents
Havells solar cables are manufactured with the following materials.
1. Annealed Tinned Copper Conductor
2. Cross Linked Polyolen Compound
3. Zero Halogen Polyolen Compound

Construction of solar cable

Flexible tinned copper stranded class -5


conductors as per IEC-60228

Insulation Cross linked


Polyolefin, Natural Color*

Outer sheath Halogen free


Polyolefin Black Color

*can be manufactured with Red/Black colour


Required Features of Solar cable
CHEMICAL FEATURES ELECTRICAL FEATURES
s 7EATHERRESISTANT s 6OLTAGERATING +6$# +6!#
s 2ESISTANTTOMINERALOILS s (IGHVOLTAGETEST+6$#FORMINUTES
s 2ESISTANTTOACIDSALKALINE MECHANICAL FEATURES
THERMAL FEATURES s 2ESISTANTTO)MPACT TEARABRASION
s -AXIMUMCONDUCTORTEMPERATUREOFOPERATION # s -INIMUMBENDINGRADIUSnTIMESOFOVERALLDIAMETER
during 20000 hours.
s 3AFEPULLINGFORCE .SQMM
s -INIMUMOPERATINGTEMPERATURE #

62
Regional & Branch Ofces

NORTH - REGIONAL OFFICE:


Corporate Ofce : QRG Towers, 2D, Sector-126, Expressway, Noida-201304, Tel: 0120-3331000
Delhi: Tel : 011-47676700, 23888200
Chandigarh: Tel : 0172-4232400-401
Dehradun: Tel: 0135-6670202
Noida / Haryana: Tel: 0120-3331000
Ludhiana: Tel: 0161-4676000 / 24
Jammu: Tel: 0191-2478330, 2479330
Sri Nagar: Tel: 0194-2490431
Jaipur: Tel: 0141-3914645, 3988210
Jodhpur: Tel: 0291-9214201640 / 45
Lucknow: Tel: 0522-6672100
Kanpur: Tel: 0512-6710400, 6710409

EAST - REGIONAL OFFICE:


Kolkata: ICC Tower, 5th Floor, 4 India Exchange Place, Kolkata-700001, Tel: 033-40129851 / 52
Bhubaneshwar: Tel: 0674-6668101/102/103/104
Guwahati: Tel: 0361-213452, 2458923, 2460355
Siliguri: Tel: 0353-2525907
Jamshedpur: Tel: 0657-6542492, 09234369436
Patna: Tel: 0612-2207221, 2207222, 2207223, 2655518

WEST - REGIONAL OFFICE:


Mumbai: 301, Everest House, 3rd Floor, 6, Suren Road, Chakala, Andheri (E). Mumbai - 400 093, Tel: 022-67298600-602
Ahmedabad: Tel: 079-40061111, 40060738-740
Indore: Tel: 0731-2572340-41, 4009998
Rajkot: Tel: 0281-2481112, 2921212
Nagpur: Tel: 0712-2240932, 2242692, 2242699
Pune: Tel: 020-64016413 / 14
Raipur: Tel: 0771-4243400 / 01
Surat: Tel: 0261-2350137, 9979890137
Jabalpur: Tel: 0761-4064491

SOUTH - REGIONAL OFFICE:


Chennai: Sigapi Achi Building, No. 18 / 3, 6th Floor, Rukmani Lakshmipathy Road, Egmore, Chennai-600008,
Tel: 044-42280600, 605
Bangalore: Tel: 080-49075000
Coimbatore: Tel: 0422-2305767, 2306199, 2305199
Hyderabad: Tel: 040-27533372, 27533355, 27533632, 66320407/0408/6401/6402
Kochi: Tel: 0484-4099000
Vishakapatnam: Tel: 0891-6514339
Vizag: Tel: 0891-6514339
Vijayawada: Tel: 91+9247058847/57
Calicut: Tel: 09895855499
Madurai: Tel: 09994493242
Trivandrum: Tel: 09633817795
Hubli: Tel: 09448146028
Trichy: Tel: 09944460160

2EPRESENTATIVE/FlCESs'OAs3OLAPURs'WALIORs+ATHMANDUs"HOPAL
ZHCMC00001/SEP14/JAN15

Although every effort has been made to ensure accuracy in the compilation of the technical detail within this publication.
Specications and performance data are constantly changing. Current details should therefore be checked with Havells Group.

Havells India Ltd.


Corp Ofce: QRG Towers, 2D, Sector-126, Expressway, Noida-201304 (U.P.)
Ph. +91-120-3331000, E-mail: [email protected], www.havells.com
Consumer Care No.: 1800 11 0303 (Tolfree), 1800 103 1313 (All Connections), 011-4166 0303 (Landline)
Join us on Facebook at www.facebook.com/havells and share your ways to save the planet!