VCD 20

The document discusses different types of directional valves: - SD5/1-N has one working section and can be used where carry-over is not required. Controls and positioning refer to parallel circuits. - SD5/1-D has one working section and can be used where carry-over is required. Controls and positioning refer to parallel circuits. - SD5-S has 2-6 sections and can be used where downstream sections must work with upstream sections simultaneously. Carry-over circuits are not available. Controls and positioning refer to parallel circuits. - SD5-SP has 2-6 sections and can be used where downstream sections are prohibited from working when upstream sections are engaged, for security

Uploaded by

chethan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
203 views5 pages

VCD 20

The document discusses different types of directional valves: - SD5/1-N has one working section and can be used where carry-over is not required. Controls and positioning refer to parallel circuits. - SD5/1-D has one working section and can be used where carry-over is required. Controls and positioning refer to parallel circuits. - SD5-S has 2-6 sections and can be used where downstream sections must work with upstream sections simultaneously. Carry-over circuits are not available. Controls and positioning refer to parallel circuits. - SD5-SP has 2-6 sections and can be used where downstream sections are prohibited from working when upstream sections are engaged, for security

Uploaded by

chethan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Other executions

SD5/1- N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 70
Its available only with one working section and it can be used in hydraulic cir-
cuits where carry--over doesnt required.
H For controls, spool positioning and valves, refer to directional valve with paral-
lel circuit.

SD5/1- D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 71
Its available only with one working section and it can be used in hydraulic cir-
cuits where carry--over is required.
H For controls and spool positioning refer to directional valve with parallel circuit.
H Configurations with service and auxiliary valves arent available

SD5- S: with series circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 72


Available from 2 to 6 sections, it can be used in systems wich one downstream
section from series connection must work with upstream ones at the same time.
H On the same body are possible more than one connection.
H Its not available the carry--over circuit.
H For controls, spool positioning and valves, refer to directional valve with paral-
lel circuit.

SD5- SP: with tandem circuit . . . . . . . . . . . . . . . . . . . . . . . . . page 74


Available from 2 to 6 sections, for security reasons it can be used in systems
which is required to prohibit engagement of downstream sections from tandem
connection when the upstream sections are working.
H On the same body are possible more than one connection.
H For controls, spool positioning and valves, refer to directional valve with paral-
lel circuit.
Dimensional data

105.5 63.5 5
4.15 2.50 0.20
14 73 45
0.55 2.87 1.77

0.33
8.5
1.34
34

3.19
103
4.06
81
7.32
186

2.01
51

spool out
45.5
1.79

1
24
0.45

0.79
11.5

20

15
0
1.81
46

15
24
M8
2

24.5 30 27 24.5
0.96 1.18 1.06 0.96 3
90 spool in
3.54

Hydraulic circuit Performance data


Pressure drop curve
A1 B1
15 (psi)
(bar) 200

10 150
P PA(B)
T
Pressure

100
PT
5
50

A(B)T
0
0 15 30 45 60
Flow (l/min)
Dimensional data (parallel circuit)

Carry--over 63,5 5
20,5 2.50 0.20
12,5 0.81 45
0.06 1.77

0.33
8,5
1.34
34

4.06
3.19
103
7.32

81
186

2.01
51

spool out
45,5
1.79

3
0.45
11,5

1
24
0.79
20

15
0
1.77
45

M8 15
24
2
23 30 37 27 24,5
0.91 1.18 1.46 1.06 0.96
90 3
3.54 spool in

E F Weight E F Weight
TYPE TYPE
mm in mm in kg lb mm in mm in kg lb
SD5/1--P 100.5 3.96 73 2.87 3.5 7.7 SD5/5--P 248.5 9.78 221 8.70 10.1 22.3

SD5/2--P 137.5 5.41 110 4.33 5.2 11.5 SD5/6--P 285.5 11.24 258 10.16 11.7 25.8

SD5/3--P 174.5 6.87 147 5.79 6.9 15.2 SD5/7--P 322.5 12.70 295 11.61 13.2 29.1

SD5/4--P 211.5 8.33 184 7.24 8.1 17.9


Outlet port options
Its possible to have open centre, closed centre and carry--over.
Unloader valves are available: these valves need special bodies with appropriate cavity on lateral outlet port, the tank connection
T must be on top.

AET: open centre (standard)


See page 9.

AE: with carry-- over AEK: closed centre

Wrench 22 --42 Nm / 31 lbft

Allen wrench 8 --42 Nm / 31 lbft


G3/8

20.5 2.5
0.81 0.1

A1 B1 A2 B2 A1 B1 A2 B2

T T

P P

120 120
1750 1750

Description example: SD5/2--P(KG3--120)/18L/18L/AE Description example: SD5/2--P(KG3--120)/18L/18L/AEK

With hydraulic pilot unloader valve type L


For safety reasons its provided with pilot port plugged.
T
Pressure drop curve A2 B2
10 12
0.39 (psi)
(bar)
150
X
9
Pressure

X 100
6
G1/4

3 50

Wrench 24
42 Nm / 31 lbft 0
0 10 20 30 40 45
Flow (l/min)
Operating features Description example:
Internal leakage . . . . . . . . . . . . . . . . . : 10 cm3/min a 100 bar SD5/2--P(JG3--120)/18L/18L/AET--L
: 0.61 in3/min at 1450 psi
Working conditions

This catalogue shows technical specifications and diagrams measured with mineral oil of 46 mm2/s -- 46 cSt viscosity at 40C tempera-
ture.

Nominal flow rating 45 l/min


Operating pressure (max.) parallel pr tandem circuit 315 bar 4600 psi
series circuit 250 bar 3600 psi
Max. back pressure on outlet port T 25 bar 360 psi
Internal leakage A(B)T p=100 bar -- 1450psi with fluid and valve at 40C 3 cm3/min 0.18 in 3/min
Hydraulic fluid Mineral base oil
Fluid temperature with NBR seals from --20 to 80C
with FPM seals from --20 to 100C
Viecosity operating range from 15 to 75 mm2/s from 15 to 75 cSt
minimum 12 mm2/s 12 cSt
maximum 400 mm2/s 400 cSt
Max. level of contamination 19/16 -- ISO 4406
with mechanical, pneumatic and hydraulic devices from --40 to 60C
Ambient temperature
with electric devices from --20 to 60C
NOTE -- For different conditions please contact Sales Dept.

Standard threads

REFERENCE STANDARDS
BSP UN--UNF METRIC NPTF
THREAD ISO 228/1 ISO 263 ISO 262 ANSI B1.20.3
ACCORDING TO BS 2779 ANSI B1.1 unified

CAVITY ISO 1179 11926 9974--1


ACCORDING TO SAE J1926 J2244 J476a
DIN 3852--2 3852--1
shape X o Y shape X o Y

PORTS THREAD
MAIN PORTS BSP UN--UNF METRICA
IInlet P and carry--over C G 3/8 3/4--16 (SAE 8) M18x1,5
Ports A and B G 3/8 9/16--18 (SAE 6) M18x1,5
G 3/8 M18x1,5
Outlet T 3/4--16 (SAE 8)
G 1/2 * M22x1,5 *
CONTROL PILOT PORTS
Pneumatics NPTF 1/8--27 NPTF 1/8--27 NPTF 1/8--27
Hydraulics G 1/4 9/16--18 (SAE 6) G 1/4
(*) -- Only for series circuit..