Electrovalvula DKI, DKU y DKOR

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Atos spa Table E020-11/E

21018 Sesto Calende, Italy - Fax 0331 920005

Solenoid directional valves type DKI, DKU, DKOR


direct operated, ISO 4401 size 10

DKI,DKU and DKOR are spool type,


three or four way, two or three position
BLEED SCREW direct operated solenoid valves desi-
connector
gned to operate in oil hydraulic
systems.
They are operated by wet and pressure
sealed solenoid  with manual overri-
de:
AI solenoid suitable for AC supply;
DKI AU solenoid for DC supply with
DKU
improved performance;
AOR solenoid for DC supply with
high performance.
BLEED SCREW Moving parts are protected, lubricated
and cushioned in oil.
connector
Shell-moulding casting  are 5 cham-
bers machined by transfer lines and
then cleaned by thermal deburring.
Optimized flow paths largely cored with
extrawide channels to tank for low
pressure drops.
DKOR
Interchangeable spools  available in
a wide variety of configurations.
DKU and DKOR valves can be sup-
1 MODEL CODE
plied with optional devices for control
DKI 1 63 1/2 /A - X 24 DC ** /* of switching times.
Directional control valves ISO 4401 size 10 Synthetic fluids Standard electric/electronic connectors
WG =water glycol
DKI-1 = solenoid AI for AC supply
PE= phosphate ester  able to satisfy the requirements of
DKU-1 = solenoid AU for DC supply
DKOR-1= solenoid OO for DC supply modern machines for electric interfa-
Design number ces characteristics.
Valve configuration, see table 
61 = single solenoid, center plus external position, Coils are fully encapsulated (class H).
spring centered External supply voltage see section 
63 = single solenoid, 2 external positions, spring offset 00 = valve without coils (only for DKI and
In DKI and DKU coils are easily repla-
67 = single solenoid, center plus external position, DKU). ceable without the aid of tools.
spring offset
70 = double solenoid, 2 external positions, without Rugged execution suitable for outdoor
springs
71 = double solenoid, 3 positions, spring centered X = without connector use.
75 = double solenoid, 2 external positions, with detent See note 2 at section  for available connectors,
77 = double solenoid, center plus external position, to be ordered separately Surface mounting ISO 4401 size 10.
without springs
Other configurations are available on request. Max flow up to 100 l/min for DKI/DKU
Spool type, see table .
and up to 120 l/min for DKOR.
Options, see note 1 at section .
Max pressure: 315 bar.

2 CONFIGURATION

-171* -1700/2 -1750/2 -1630/2 -161* -167*


-1701/2 -1751/2 -1631/2

-1630/2/A -161*/A -167*/A -177*


-1631/2/A Where the symbol doesn't show the hydraulic con-
nection (*), it depends on the central configuration of
the spool; see table .

3 SPOOLS - for intermediate passages, see tab. E001.

0 1 2
0/2 3 4 5 5/1 6
1/2 2/2

7 8 90 09 91 19 93 39

94 49 16 17 58
See note 3 at section .

E020
4 MAIN CHARACTERISTICS OF DKI, DKU AND DKOR DIRECTIONAL VALVES

Assembly position / location Any position for all valves except for type - 170* (without springs) that must be installed with horizontal
axis if operated by impulses
Commissioning For correct AC operation, the valve must be full of hydraulic fluid, otherwise some vibrations may
occur. In this case fill the valve with oil by opening the screw , see sketch at section 10 and 11 .
A check valve on T line aids to keep valve full.
Subplate surface finishing Roughness index flatness ratio 0,01/100 (ISO 1101).
Ambient temperature from -20C to +70C.
Fluid Hydraulic oil as per DIN 51524 .... 535; for other fluids see section .
Recommended viscosity 15 100 mm2/s at 40C (ISO VG 15 100).
Fluid contamination class ISO 19/16, achieved with in line filters at 25 m value to 25 75 (recommended).
Fluid temperature -20C +60C (standard and /WG seals) -20C +80C (/PE seals)
Flow direction As shown in the symbols of tables  and .
Operating pressure Ports P,A,B: 315 bar;
Port T: 120 bar for DKI; 160 bar for DKU and 210 bar for DKOR; 315 bar for option Y.
For versions with proximity switches (/FI/NC and /FI/NO versions) port Y must be drained
Rated flow See diagrams Q/p at section .
Maximum flow 100 l/min for DKI and DKU; 120 l/min for DKOR, see operating limits at section .
4.1 Coils characteristics
Insulation class H (180C) Due to the occuring surface temperatures of the solenoid coils, the European standards
EN563 and EN982 must be taken into account
Connector protection degree IP 65
Relative duty factor 100%
Supply voltage and frequency See electric feature 
Supply voltage tolerance 10%

5 NOTES
1 Options
A = Solenoid mounted at side of port B (only for single solenoid valves). In standard versions, solenoid is mounted at side of port A.
WP = prolonged manual override protected by rubber cap (standard for DKOR models).
L, L1, L2, L3, LR, see sec. 10 = device for switching time control (only for DKU and DKOR models).
Not available for valves with connectors E-SA or E-SE. For spools 4, 4/8, 5/1 only device L1 is available.
F * = with proximity switch for monitoring spool position: see tab. E110.
Y = external drain - not available for DKI-163* and DKI-175* (standard for versions with proximity switches /F*)
2 Type of electric/electronic connector with connector DIN 43650 to be ordered separately
SP-666 = standard connector IP-65 for direct connection to electric supply source.
SP-667 = as SP-666, but with built-in signal led.
SP-669 = with built-in rectifier bridge for supplying DC coils by alternate current (AC 110V and 230V - Imax 1A).
E-SA = electronic connector (only for DKI and DKU valves) which improves performances and give faster shifting times for DC solenoid supplied by AC power.
E-SE = electronic connector (only for DKI and DKU valves) which improves performances and reduces power consumption for DC solenoid sup-
plied by DC power.
E-SR = electronic connector which permits switching of solenoid valves by a low power signal (max 20mA).
E-SD = electronic connector which eliminates electric disturbances when solenoid valves are de-energized.
Note: disturbance suppressor devices, similar to E-SD are, standard, built in all E-SA, E-SE, E-SR.
3 Spools
- spools type 0/2, 1/2, 2/2 are only used for two position valves: single solenoid valves, type DK*-163*/2; double solenoid valves type DK*-170*/2
and DK*-175*/2.
- spools type 0 and 3 are also available as 0/1 and 3/1 that, when in centre position, oil passage from ports to tank are restricted.
- spools type 1,4 and 5 are also available as 1/1, 4/8 and 5/1. They are properly shaped to reduce water-hammer shocks during the swiching.
Note that the configuration of spool 5/1 is inverted in respect with spool 5: see section .
- spools type 1,3 and 1/2 are also available as 1P, 3P and 1/2P to limit valve leackage.
- Other types of spools can be supplied on request.

6 ELECTRIC FEATURES

External supply Power Code of spare coil


(1) Coil can be supplied also with 60 Hz of volta-
Type of Colour of
Valve nominal voltage consumption ge frequency: in this case the performances
connector DKI DKU coil label
10% (2) are reduced by 1015% and the power
6 DC - SP-CAU-6DC/ 80 brown consumption is 90 VA.
9 DC - SP-CAU-9DC /80 light blue
12 DC - SP-CAU-12DC /80
(2) Average values based on tests performed at
green
14 DC - SP-CAU-14DC /80 brown nominal hydraulic condition and ambient/coil
18 DC - SP-CAU-18DC /80 blue temperature of 20C.
24 DC 52 W - SP-CAU-24DC /80 red (3) In a cycle, where solenoid is energized/dee-
28 DC - SP-CAU-28DC /80 silver
48 DC - SP-CAU-48DC /80
nergized in 1 second (1 Hz), the average
silver
110 DC SP-666 - SP-CAU-110DC /80 gold power consumption is 13 W; for longer cycles,
125 DC or - SP-CAU-125DC /80 blue the power consumption is lower.
220 DC SP-667 - SP-CAU-220DC /80 black When solenoid is energized the inrush current
24/50 AC
SP-CAI-24/50/60AC /80 (1) - is 9 A at 12 VDC and 6 A at 24 VDC correspon-
24/60 AC
DKI 48/50 AC ding to power consumption peak of 130 W.
DKU 48/60 AC SP-CAI-48/50/60AC /80 (1) - These current peaks persist for a period
110 VA
110/50 AC (5) SP-CAI-110/50/60AC /80 (1) yellow shorter than 100 msec and they must be
120/60 AC SP-CAI-120/60AC /80 -
white
considered when electric circuit is designed.
230/50 AC SP-CAI-230/50/60AC /80 (1) light blue
230/60 AC SP-CAI-230/60AC /80 -
silver (4) When solenoid is energized the inrush cur-
12 DC - SP-CAU-6DC /80 rent is 7 A at 110 VAC and 3,5 A at 230 VAC;
E-SE 13 W (3) green
24 DC - SP-CAU-12DC /80 the power consumption peak is 800 VA;
110/50 AC 105 VA
- SP-CAU-24DC /80 red these current peaks persist for a period shor-
120/60 AC E-SA 95 VA
230/50 AC (4) 105 VA ter than 40 msec and they must be conside-
- SP-CAU-48DC /80 silver
230/60 AC 95 VA red when electric circuit is designed.
110/50 AC 58 VA (5) When solenoid is energized, the inrush cur-
- SP-CAU-110RC /80 gold
120/60 AC 53 VA
SP-669 rent is approx 3 times the holding current.
230/50 AC 58 VA
- SP-CAU-230RC /80 blue Inrush current values correspond to a power
230/60 AC 53 VA
consumption of about 350 VA.
External supply Power External supply Power
Type of Type of
Valve nominal voltage consumption Valve nominal voltage consumption
connector connector
10% (2) 10% (2)
12 DC 110/50 AC 46 W
SP-666 40 W
DKO 24 DC DKOR 120/60 AC 42 W
or SP-669
110 DC 230/50 AC 46 W
SP-667 46 W
220 DC 230/60 AC 42 W
7 Q/P DIAGRAMS based on mineral oil ISO VG 46 at 50C DKI - DKU DKOR
D D
Flow direction
PA PB AT BT PT C

Valve pressure drop p [bar]

Valve pressure drop p [bar]


Spool type
C
0, 2, 3 B B B B
B
0/2, 1, 8 B B A A
B
A
1/2, 2/2 C C B B
A
4, 5, 9* D D D D C

6 B B A B

7 B B B A
Flow rate [l/min] Flow rate (l/min)

8 OPERATING LIMITS based on mineral oil ISO VG 46 at 50C


The diagrams have been obtained with warm solenoids and power supply at lowest value (Vnom - 10%). The curves refer to application with symmetrical flow
through the valve (i.e. PA and BT). In case of asymmetric flow and if the valves have the devices for controlling the switching times the operating limits
must be reduced.
DKI DKU DKOR

X M

M S
Inlet pressure [bar]

Inlet pressure [bar]


Inlet pressure [bar]

M T
S V
V T
V
Y
Y

Flow rate [l/min] Flow rate [l/min] Flow rate [l/min]

M = Spools 0, 1, 1/2, 3. X = Spools 0, 0/2, 1, 1/2, 3, 6, 7, 8 with E-SA or E-SE M= Spools 0, 0/2, 1, 1/2, 8.
Y = Spools 0/2, 4, 5, 6, 7. connector. S= Spools 3, 6, 7.
V = Spools 2, 2/2, *9, 9*. M = Spools 0, 1, 1/2, 8. V= Spools 2, 2/2, *9, 9*
S = Spools 0/2, 3, 6, 7. T= Spools 4, 5.
Y = Spools 2, 2/2, *9, 9* with E-SA or E-SE connectors.
V = Spools 2, 2/2, *9, 9*.
T = Spools 4, 5.

9 SWITCHING TIMES (average values in msec)


DKI DKU DKOR
Valve Switch-on Switch-on Switch-off Valve Switch-on Switch-on Switch-off Valve Switch-on Switch-on Switch-off
AC DC AC DC AC DC
DKU + SP-666
SP-667 60 30 SP-666
DKI + SP-666 35 60 30 DKOR +
SP-667
65 35
SP-667 DKU + SP-669 60 90
DKU + E-SA 25 45 DKOR + SP-669 65 95
DKU + E-SD 60 60 E-SD
E-SR DKOR + 65 65
DKU + E-SE 40 40 E-SR

DKU-*/L* 75-150 45-150 DKOR-1**/L* 75-150 50-150


Test conditions:

- 50 l/min; 150 bar


- nominal voltage
- 2 bar of counter pressure on port T
- mineral oil ISO VG 46 at 50C

The elasticity of the hydraulic circuit and the variations of the hydraulic characteristics and temperature affect the response time.

10 DEVICES FOR SWITCHING TIME CONTROL


These devices are only available for DKU and DKOR without E-SA or E-SE and can
check the switching time and therefore reduce the coil hammering in the circuit. The
different types available are shown in the figure.
The functionality of the device depends on the type of regulating element.
- L : checks and regulates the switching time in both moving directions of the spool:
regulation is carried out by screwing/unscrewing the element itself (regulating
choke);
- L1/L2/L3: checks the switching time in both moving directions of the spool with fixed
regulation of this time (gauged flow)
L1 = 1,25 mm; L2 = 1 mm; L3 = 0,75 mm;
- LR checks and regulates the switching time in the ba direction of the spool move-
ment. The device does not intervene in the control of the switching time (standard
time) in the opposite direction ab of the spool movement.

In all cases where it is necessary to obtain damped switching, pair these devices with SPOOL DIRECTION
progressive spools (1/1, 4/8, 5/1) which in the intermediate passages are properly sha-
ped to reduce reversal shocks. a b = sol. energizing a / sol. de-energizing b
The passage in which the regulating element is inserted must be completely full of fluid a b = sol. energizing b / sol. de-energizing a
for it to function properly, see also commissioning at section .

E020
11 INSTALLATION DIMENSIONS [mm]

Mounting surface
ISO 4401-AC-05-4 size 10
Fastening bolts: 4 socket head screws M6x40
Seals: 5 OR 2050.1 OR 108
Ports P,A,B,T: = 11.5 mm (max)
Ports Y: = 5 mm

P = PRESSURE PORT
A, B = USE PORT
T = TANK PORT
Y = DRAIN PORT (only for option /Y)
For the max pressures on ports, see section

DKI-16 DKI-17
DKU-16 DKU-17

Mass: 3,8 kg Mass: 4,4 kg

DKOR-16 DKOR-17

Mass: 4,9 kg Mass: 6,1 kg

Overall dimensions refer to valves with connectors type SP-666

12 ELECTRIC/ELECTRONIC CONNECTORS ACCORDING TO DIN 43650 - The connectors must be ordered separately

SP-666, SP-667 SP-669 E-SA (for AC supply) E-SR/DC (for DC supply) E-SD/AC
(for AC or DC supply) (for AC supply) E-SE (for DC supply) (for AC supply)
E-SD/DC E-SR/AC (for AC supply)
(for DC supply)
BLUE
RED
YELLOW
WHITE

CONNECTOR WIRING
SP-666, SP-667 SP-669 E-SA Power supply VDC: Pilot signal VDC: 1,2 = Supply voltage VAC
1 = Positive 1,2 = Supply voltage VAC 1,2 = Supply voltage VAC RED = Positive YELLOW = Positive +24VDC
2 = Negative 3 = Coil ground 3 = Coil ground BLUE = Ground WHITE = Negative
= Coil ground E-SE
1 = Positive 2 = Negative
E-SR/AC
1,2 = Supply voltage VAC
3 = Coil ground
4 = Negative pilot signal VDC
5 = Positive pilot signal +24VDC Supplied with 5 m long cable.

SUPPLY VOLTAGES
SP-666 SP-667 E-SD-DC E-SA E-SE E-SR-AC
AC or DC 110/50 AC 110/50 AC 12 DC All 12 DC All AC voltages
All 24 All DC 120/60 AC 120/60 AC 24 DC voltages 24 DC
voltages 110 voltages 230/50 AC 230/50 AC
220 230/60 AC 230/60 AC

13 MOUNTING SUBPLATES

Counterbore
GAS Ports Mass
Model Ports location [mm]
A-B-P-T (X-Y) [kg]
A-B-P-T (X-Y)

BA-308 (/Y) Ports A, B, P, T (X, Y) underneath 1/2" (1/4") 30 (21,5) 2,5

BA-428 (/Y) Ports A, B, P, T (X, Y) underneath 3/4" (1/4") 36,5 (21,5) 5,5

BA-434 (/Y) Ports P, T, (X, Y) underneath; Ports A, B on lateral side 3/4" (1/4") 36,5 (21,5) 8,5
09/04
The subplates are supplied with 4 fastening bolts M6x40. Also available are multi-station subplates and modular subplates. For further details see table K280.