Product Information DIGSI 5 V07.30

Download as pdf or txt
Download as pdf or txt
You are on page 1of 48

DIGSI 5

V7.30

Product Information

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 1
Note
This Product Information contains important information about DIGSI 5 V7.30.
It is part of the product supplied. In case of uncertainties this information should be
considered more up-to-date than any other information.

Disclaimer of Liability Copyright


This document has been subjected to rigorous technical Copyright Siemens AG 2016.
review before being published. It is revised at regular All rights reserved.
intervals, and any modifications and amendments are
included in the subsequent issues. The content of this The disclosure, duplication, distribution and editing of this

document has been compiled for information purposes document, or utilization and communication of the content
only. Although Siemens AG has made best efforts to keep are not permitted, unless authorized in writing. All rights,
the document as precise and up-to-date as possible, including rights created by patent grant or registration of a

Siemens AG shall not assume any liability for defects and utility model or a design, are reserved.
damage which result through use of the information
contained herein.

Registered Trademarks
This content does not form part of a contract or of business
relations; nor does it change these. All obligations of SIPROTEC, DIGSI, SIGUARD, SIMEAS, and SICAM are

Siemens AG are stated in the relevant contractual registered trademarks of Siemens AG. Any unauthorized
use is illegal. All other designations in this document can
agreements.
be trademarks whose use by third parties for their own
Siemens AG reserves the right to revise this document purposes can infringe the rights of the owner.
from time to time.

Document Release C53000-X5050-C001-C.00


Edition 06/2016

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 2
Table of Contents
1 Contents of the Consignment .......................................................................... 5

2 Open Source Software ...................................................................................... 6

3 Hardware Requirements ................................................................................... 7

4 Software Requirements .................................................................................... 8

5 Installation ........................................................................................................ 12

6 Release Notes .................................................................................................. 19

7 Features ............................................................................................................ 19

8 Support ............................................................................................................. 24

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 3
DIGSI 5 V7.30
Dear customer,

This DVD-ROM contains DIGSI 5 in its current version V7.30, the PC program for
configuring, parameterizing, and operating SIPROTEC 5 protection, combination, and bay
devices.

With a PC or a notebook, you can parameterize the devices via the interfaces and export
and visualize the fault data. DIGSI 5 comes in different variants (Compact, Standard, and
Premium) that provide different functionalities. Please refer to the catalog to see which
variant provides the needed features:

The Single-Line Editor allows you to define a substation and the primary equipment
graphically. Connect those elements to the protection functions of your protection
devices.

The graphic display of the SIPROTEC devices can be designed and edited with the
Display Editor as well as with a graphics program. Take your single-line diagram and
convert it into a display picture. You can define your own symbols as well.

You can configure additional functions like interlocking of the devices graphically with
the CFC Editor.

The Siemens IEC 61850 System Configurator allows you to configure and parameterize
IEC 61850 stations. With this tool you to manage subnets, network communicators, and
their IP addresses and connect the information items of different communicators.

DIGSI 5 Test Suite provides a rich set of test tools that speeds up your commissioning
phase and supports you during operations. One of the test features is the possibility to
create and execute test sequences to issue device tests without external test
equipment.

SIGRA for analyzing fault records, for example those recorded by fault recorders when
there are faults in power plants, in a simple, rapid, and convenient manner.

DIGSI 5 is available in English, German, French, Portuguese, Spanish, Turkish, Russian


and Italian.

To use DIGSI 5 Standard and Premium, you need a license key for each computer you are
running DIGSI 5 on. If you execute the software without a license key, it will be always
available as DIGSI 5 Compact edition or as a Trial version for 30 days.

All other licenses are provided on USB sticks. For license key handling, see chapter 5.4.

Installation Notes
The installation notes in this document contain important information required to
install DIGSI 5. Read these notes before installing the software.

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 4
1 Contents of the Consignment
1.1 Content and Structure of the Product

DVD DIGSI 5 V7.30 Operating Program for SIPROTEC Devices

DIGSI 5 V7.30 in all variants including IEC 61850 System Configurator to parameterize
SIPROTEC 5 protection devices

Option package SIGRA (see Product Information SIGRA)

IEC 61850 Browser for displaying files according to IEC 61850

Demo version of GOOSE inspector (a tool for analyzing GOOSE network traffic)

DVD DIGSI Device Drivers and Manuals

All device drivers released by 06/2016.

All manuals released by 06/2016.

DVD SIPROTEC 5 and DIGSI 5 Tutorial

A comprehensive video tutorial introducing the features of SIPROTEC 5 and DIGSI 5 for an
easy start with the devices and their parameterization.

Content and Structure of Download Version

The content of the download version is similar to the DVD DIGSI 5 V7.30 content but
without IEC 61850 Browser and GOOSE inspector.
The download version can only be used to update an earlier DIGSI 5 installation. It cannot
be executed on a machine without earlier DIGSI 5 installation.

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 5
2 Open Source Software
Among other things, this product contains Open Source Software that was developed by
third parties and software copyrighted by Chris Maunder, 1998. The Open Source
Software included with this product and the relevant Open Source Software license
agreement can be found in Readme_OSS.

The Open Source Software program is protected by copyright. You are permitted to use the
Open Source Software according to the Open Source Software license agreement. Should
contradictions occur between the Open Source Software license conditions and the
Siemens license conditions applicable to the product, the Open Source Software license
agreement with respect to the Open Source Software shall prevail.

The Open Source Software is provided free of charge. If stipulated by the Open Source
Software license agreement, the source text of the software is available until the end of the
third year after purchasing the product. Shipping charges will apply separately. We are
liable for the product including the Open Source Software according to the license
agreement for the product. Any liability arising from the use of the Open Source Software
that exceeds the intended program flow of the product, as well as liability for defects that
were caused by changes made to the Open Source Software, is excluded. If the product
was modified, we cannot provide technical support.

DIGSI 5 also uses WindowBlinds: DirectSkin Stardock.

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 6
3 Hardware Requirements
To work with DIGSI 5 V7.30, you need a PC or laptop computer with the following minimum
specifications independent from the used operating-system version:

Intel Celeron Dual Core 2,2 GHz (Ivy/Sandy Bridge)


5 GB free disk space on the hard disk (Solid State Disk (SSD) recommended)
4 GB of RAM (8 GB recommended)
Graphic display HD ready 1280 x 1024 or 1376 x 768 Pixels
DVD-ROM drive
Keyboard and mouse
USB port

If you are dealing with comprehensive projects with several protection devices, for
example, Siemens recommends using a PC meeting the latest standards of performance.

NOTE
If you use DIGSI 5 on a laptop computer with power management, then Siemens
recommends using DIGSI 5 on that laptop computer while it is attached to an external
power outlet. This avoids power drops due to energy-saving modes of the laptop
computer running on batteries.

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 7
4 Software Requirements
4.1 Startup Environment

Operating Systems

DIGSI 5 V7.30 is an application whose functionality has been designed especially for the
following operating systems:

Microsoft Windows 7 Professional and Enterprise/Ultimate 32-bit and 64-bit with


Service Pack 1
Microsoft Windows 8.1 64-Bit
Microsoft Windows Server 2012 R2 64-bit with Service Pack 1 as workstation computer
VMWare support for virtual machines (for more details, see the following list)
Siemens recommends using 64-bit operating systems!

DIGSI 5 V7.30 has not been tested for the following operating systems:

Microsoft Windows 8 32-Bit and 64-Bit


Microsoft Windows 8.1 32-Bit
Microsoft Windows Server 2012 as workstation computer
Microsoft Windows Server 2008 R2 with Service Pack as workstation computer
If you use these operating systems with DIGSI 5 V7.30, it is at your own risk.

DIGSI 5 V7.30 cannot be installed or operated under:

Microsoft Windows XP and older Microsoft operating systems


Microsoft Windows 7 Starter, Home Basic, Home Premium
Microsoft Windows Server 2003, 2008 and 2008 R2 without Service Pack
Microsoft Windows 10

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 8
Virtual Environment
DIGSI 5 V7.30 supports the virtual environment VMWare (for more information, see
http://www.vmware.com).

The features of the Virtual Machine have been approved on the following operating
systems:
Microsoft Windows 7 Professional and Ultimate/Enterprise 32-bit and 64-bit with
Service Pack 1
Microsoft Windows 8.1 64-Bit

The performance of DIGSI 5 is not ensured under other operating systems. If you use these
operating systems, it is at your own risks.

NOTE
If you are using multiple Ethernet adaptors in your PC, you need VMWare
Workstation to select the correct Ethernet adaptor for the connection of DIGSI 5 to the
devices. If just one Ethernet adaptor is present, then the free-of-charge VMWare
Player is sufficient to run DIGSI 5.

Network Environment
DIGSI 5 V7.30 uses HTTP connections for the communication. Address conflicts and faulty
proxy settings can block this communication. For USB and the offline function chart (CFC)
analysis (debugging), following IP-address bands are used:

- USB:
Network-adaptor name: SIPROTEC 5 devices connected via USB
Address band: 192.168.2.*
Subnet mask: 255.255.255.0

- Offline function chart (CFC) analysis (debugging):


Network adaptor name: S2010_vHub
Address band: 192.168.100.*
Subnet mask: 255.255.255.0

These address bands must not be used by another active network adaptor. Otherwise, the
USB-connection to the device or the offline function chart (CFC) analysis (debugging) will
not work.

Proxy Settings

If you use a proxy, make sure that the IP-address bands named before are defined as
exceptions in the proxy settings.

In any case, make sure that the proxy settings match your network configuration. Contact
your network administrator for further assistance.

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 9
4.2 Compatibility with other Software

DIGSI 5

Projects created with DIGSI 5 versions before DIGSI 5 V3.00 are not supported by DIGSI 5
V7.30.

DIGSI 4

The usage of DIGSI 5 V7.30 and any available DIGSI 4 on the same system is possible.

NOTE
If you install DIGSI 4.82 or earlier after DIGSI 5, you need to reinstall the latest
Automation License Manager (ALM) after installation of DIGSI 4. ALM setup is
provided on the DIGSI 5 DVD in the folder \Automation License Manager.

IEC 61850 System Configurator

DIGSI 5 V7.30 installs the IEC 61850 System Configurator V5.30.


It is possible to install IEC 61850 System Configurator versions older than 5.00 in parallel
on the same system.

SIGRA

DIGSI 5 comes with SIGRA V4.58. This version is fully compatible with the older versions
of SIGRA.

TOOLBOX II

The usage of DIGSI 5 V7.30 and TOOLBOX II V4.10 SP1 on one system is possible.

SICAM PAS

The usage of DIGSI 5 V7.30 and SICAM PAS 6.0 SP5 and SICAM PAS 7.0 on the same
system is possible.

Spectrum PowerCC IMM

The usage of DIGSI 5 V7.30 and Spectrum PowerCC IMM V4.20 on one system is
possible.

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 10
STEP7 V5.x

The usage of DIGSI 5 V7.30 and the automation software STEP 7 V5.x on the same
system is possible without restrictions.

Virus-Scanner Software

So far no incompatibilities between commercially available Malware Protection Software


and DIGSI 5 V7.30 are known. Trend Micro OfficeScan has been explicitly tested.

Hard-Disk Error-Checking Software

If you follow the following guidelines, hard-disk error-checking software can be used with
DIGSI 5 V7.30.
The license key is connected on the target disk drive with a specially marked cluster. Some
hard-disk error-checking software shows this cluster as defect. Do not try to restore this
cluster.

Hard-Disk Defragmentation Software

Hard-disk defragmentation software can be used with DIGSI 5 V7.30 if you follow the
following guidelines:
If you are using hard-disk defragmentation software that allows relocating unmovable
blocks, you can only use that option if you have transferred the license key from your hard
disk back to you license stick. Otherwise, this option will destroy the license file.

Rational ClearCase

DIGSI 5 V7.30 projects must not be stored on ClearCase drives (drives that are linked to
a ClearCase View (MVFS)).

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 11
5 Installation
5.1 General Notes on Installation

NOTE
Before installing DIGSI 5 V7.30, consider the following:
In order to upgrade existing projects including IEC 61850 from DIGSI 5 version 5.xx
and earlier to V7.xx, certain mandatory steps must be executed. These steps are
described in the document Readme_DIGSI_5_Upgrade_Guideline.pdf.
Read this guideline carefully and follow the steps described before installing DIGSI 5
V7.30. You can find the document on the DIGSI 5 V7.30 DVD or download it from the
Internet (http://www.siemens.com/digsi).

NOTE
You need administrator rights to install DIGSI 5.

If you are using Windows 7, Siemens recommends not installing DIGSI 5 to the root
directory of a drive.

If you are using Windows 7 with a Chinese language option, Siemens recommends
installing DIGSI into the directory suggested during installation (if necessary on another
drive).

For optimum display of the information during setup, Siemens recommends setting the
colors in the control panel of your computer to at least 65 536 colors.

Before starting the installer, close all applications (such as MS Word) and the control-panel
window, since you must restart your computer following the DIGSI 5 installation.

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 12
5.2 Installation of Download Version over Existing DIGSI 5
Installation
Close any running DIGSI 5 application before installing DIGSI 5 V7.30.
Decompress the files to a local folder on your PC. Keep the directory structure as it is in
the ZIP archive.
Execute Setup.exe. This will install DIGSI 5 V7.30 over your older DIGSI 5 installation.
During the setup a new USB driver is installed along with DIGSI 5. Confirm eventually
upcoming message boxes with Install.
Once the setup is completed and the machine is rebooted, you can delete the
decompressed files.

5.3 Installation of DIGSI 5 from DVD


Insert the DIGSI 5 DVD called DIGSI 5 V7.30 Operating Program for SIPROTEC
Devices in the drive. The DIGSI 5 installer will guide you through the installation. The
installer starts automatically after inserting the DIGSI 5 DVD. If you have disabled the
autorun function on your computer, start the installer with the Microsoft Windows Explorer
by double-clicking on the SETUP.EXE in the root directory of your DVD drive.

Follow the on-screen instructions of the installer:

All variants of DIGSI 5 with all necessary components will be installed on the system.
For the installation, no license key is required (it will be requested on the first start of the
DIGSI 5 application).
Select the installation path for DIGSI 5. The recommended installation path is
C:\Program Files\Siemens Energy\DIGSI 5 V7.30.
You can select any drive you want to install DIGSI 5 on. Sufficient hard-disk space must
be available.
Select a local hard-disk drive as target for the installation. It is not possible to install
DIGSI 5 on a network drive.
If you want to change the default installation path, make sure that you do not install
directly to the root directory (for example, D:) of your hard disk. Maintain at least one
subdirectory such as DIGSI 5.
Do not install DIGSI 5 in a directory whose path contains non-ASCII characters.
Click Install to start the installation.
During the setup a new USB driver is installed along with DIGSI 5. Confirm eventually
upcoming message boxes with Install (Windows 7/8.1).
Depending on the installed components, a reboot of the system might be required and
will be initiated by the installer.
Start DIGSI 5 from the Start menu. Select Start > Siemens Energy > DIGSI 5 V7.30 >
DIGSI 5 V7.30.

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 13
5.4 Installing the DIGSI 5 License

General Information about DIGSI 5 Licenses

Each ordered license allows the usage of DIGSI 5 on one system. DIGSI 5 can be ordered
with license bundles of 1, 5, and 10 licenses per bundle, therefore allowing the usage of
DIGSI 5 on 1, 5, or 10 systems at the same time.

Different licenses are available for DIGSI 5 Standard and DIGSI 5 Premium, providing
different functionality of DIGSI 5. Additionally, option packs are available, for example
SIGRA as an addition to DIGSI 5 Standard. Those option packs come also with license
keys that enable the usage of those features in DIGSI 5.

DIGSI 5 licenses are delivered on USB sticks. The license is transferred onto a system
using the so called Automation License Manager (ALM). See the next chapter for a short
introduction on how to use the Automation License Manager to transfer licenses.

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 14
How to Install DIGSI 5 Licenses

NOTE
The installed licenses can be destroyed using incompatible virus-scanner tools or
disk-defragmentation tools. Refer to the information about Compatibility with other
Software in chapter 4.2.

If a license is broken, contact the Siemens hotline


(http://support.automation.siemens.com/WW/view/de/772175) and have either your
certificate of license or your USB stick with the license ready to provide the necessary
information to the hotline to repair the license.

Each USB stick contains a certain number of Emergency licenses that can be used in
case of a broken license to continue working for 14 days. Install that Emergency
license when needed from the USB stick while the hotline is working on your license
issues, but do not use the Emergency license in any other case.

Each time DIGSI 5 starts and recognizes that no license key is installed so far, it provides
you with several options:

1. Install a license key for DIGSI 5 Standard or DIGSI 5 Premium.

2. Run as DIGSI 5 Compact, allowing a very limited set of functionality to be used.

3. Start a Trial period, which allows you to use DIGSI 5 Premium in Trial mode for 30
days on the system. After 30 days, you need either a valid license key for DIGSI 5
Standard or DIGSI 5 Premium to continue working or you can use DIGSI 5
Compact. Be aware that DIGSI 5 Compact does not provide all functionality you
might have used while working with DIGSI 5 Premium Trial.

For a detailed list of functionality available in the different DIGSI 5 variants, refer to the
SIPROTEC 5 catalog. This allows you to select the appropriate DIGSI 5 variant for your
purposes.

When you select to install a license key, the Automation License Manager is started and
allows you to install a license key, while DIGSI 5 is waiting for you to return to DIGSI 5.

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 15
Installing License from USB Stick

In order to install a license key, you simply plug the USB stick, which was packaged with
your DIGSI 5 delivery, into a USB port of your computer.

The USB stick is immediately recognized and displayed by the Automation License
Manager.

In the tree on the left, select the USB stick containing the licenses. The list of available
licenses will be displayed on the right side of the Automation License Manager.

1. Select the appropriate license with the mouse.


2. Right-click to show the context menu. Select Transfer
3. In the dialog shown, select any of your local hard drives.
4. Click OK to transfer the license to your hard disk
5. Close the Automation License Manager and return to the DIGSI 5 window.

Installing License via the Network

You can transfer licenses from a different computer using a network connection.
1. In the Edit menu in the Automatic License Manager, click on Connect Computer.
2. Under Computer Name, enter the name of a computer on the network or select
one from the list box.
To search for a computer in the network, click Browse.
3. Click OK to confirm.

The computer has been added in the navigation area. In order to transfer a license on your
computer, follow steps 1 to 5 in the chapter Installing License from USB Stick.

NOTE
On connection errors, please see the Settings toolbox in the File menu. Here you can
select to forbid or allow the transfer of licenses from or to your computer. For further
help, see the help menu.

NOTE
There are several other ways of transferring licenses between systems. Please refer
to the help menu in the Automation License Manager for a description of the other
possibilities (especially, Working with the Automation License Manager Using
License Keys in the Network / Access Protection for Automation License Manager).

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 16
Upgrading DIGSI 5 Standard to DIGSI 5 Premium

You can upgrade the license from DIGSI 5 Standard to DIGSI 5 Premium with an Upgrade
license, using the Automation License Manager (ALM).
1. Copy the Upgrade license from the USB stick to your local hard disk (see chapter
Installing License from USB Stick).

2. Select the license you want to upgrade.

3. In the menu bar, select License Keys and afterwards Upgrade

If there is only one possibility for an upgrade, it is performed without further messages and
prompts.
If there are several possibilities for upgrading, the License Key Upgrade dialog opens:
Select the upgrade to be performed and click on the Upgrade button.

Problems with Lost or Damaged Licenses

If you have the problem that the license(s) cannot be found by DIGSI 5 or SIGRA, refer to
the log view of the Automation License Manager (ALM) to see if someone moved the
license(s) off your computer:

1. In the Automation License Manager click on View Log.

2. On the left, select an adequate period, for example, Last 100 entries.

3. On the right the previous transfers of licenses from, to, and on your computer are
displayed.

If the problems still exist, contact the Siemens hotline


(http://support.automation.siemens.com/WW/view/de/772175). Keep either your certificate
of license or your USB stick with the license ready to provide the necessary information to
the hotline to repair the license.

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 17
5.5 Installation of DIGSI Device Drivers
In order to work with SIPROTEC 5 devices, DIGSI 5 needs so-called DIGSI device
drivers. These device drivers are located on the DVD called DIGSI Device Drivers and
Manuals.

When DIGSI 5 is started it checks if you have already installed any device drivers. If not,
DIGSI 5 asks you to do so and directly guides you to the installation dialog.

NOTE
You can always reach that device-driver installation dialog through the main menu of
DIGSI 5 (Tools > Import device driver) if you need to add any device drivers later.

1. In the Import device driver dialog, select all device driver files you want to be
available within DIGSI 5. To do so, select all *.DDD files you need and click OK.

2. The device drivers you have selected are analyzed and a tree of available
device-driver versions is presented.

3. Select the elements from the tree you want to install (a maximum of 15 is allowed
per import) and click Install.

4. In order to install the DIGSI device drivers, DIGSI 5 must restart at the end of the
process. Therefore, any open project is saved, closed and after the restart of
DIGSI 5 reopened.

Now you are ready to work with DIGSI 5.

5.6 Deinstallation
With the Windows uninstaller, you can remove DIGSI 5 with all optional components from
your PC. During deinstallation, the installer of DIGSI 5 removes all program files installed.
The user-specific data like projects remain unaffected.

Select Control Panel in the Windows Start menu and open Programs >
Uninstall a program.

In the list, select Siemens DIGSI 5 V7.30.

Click Remove to start the deinstallation. Follow the installation instructions.

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 18
6 Release Notes
6.1 Additional Orders
If you want to install components of DIGSI 5, that you have not ordered before, order these
components with specification of the license key: You will receive a new license key that
enables the additional components. A reinstallation of DIGSI 5 is not required.

7 Features
For a list of the features of DIGSI 5 please refer to the SIPROTEC 5 System Overview
catalog (E50001-K4605-A011-A1-7600).

7.1 New Features and Modifications in DIGSI 5 V7.30


1. Support of the new SIPROTEC 5 V7.30 device version
DIGSI 5 V7.30 supports SIPROTEC 5 devices from firmware version V1.xx to V7.30.
2. Copy/paste of functions and function groups
Functions and function groups can now be copied within a device as well as between
different devices.
3. CFC subcharts and templates
CFC charts can be created as subcharts and reused as part of other plans within the same
device or across different devices. This leads to a significant reduction of complexity when
working with large CFC charts. In addition, CFC subcharts can be stored as templates in
user-defined libraries and transferred to other projects or DIGSI 5 installations.
4. Trend view/dynamic display for CFC analysis
The offline and online analysis functions for Continuous Function Charts (CFC) now
support the monitoring of selected binary and analog CFC signals over time. The state
changes are shown in a diagram which simplifies the understanding of logical flows and
debugging of complex CFC charts. Alternatively, the current values of selected CFC
signals can be easily monitored in a new tabular view.
5. Cross-reference list of all signals used in CFC
List of all signals used in a CFC within the current project. A double-click on a particular list
entry will open the respective CFC plan and highlight the selected signal.
6. Write protection for CFCs
New protection level to enable read-only access to selected CFCs.
7. Enhanced device comparison
The device comparison function now also considers name differences, for example, for
signal and function-group names, and offers various usability improvements.
8. Display of short product code for SIPROTEC 5 devices
The device information section in DIGSI 5 and the HMI on SIPROTEC 5 devices now also
display the short product code.

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 19
9. Significant reduction of project size with respect to logs
For DIGSI 5 projects containing a large amount of log data, the project size on disk has
been significantly reduced.
10. TEA-X enhancements and improvements
The XML-based data exchange format TEA-X now also includes information from IEC
61850 flexible engineering. Furthermore, the TEA-X import dialog has been redesigned in
order to improve usability.
11. Several other minor improvements and error corrections

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 20
7.2 Known Problems and Limitations
1. Number of devices

Situation DIGSI 5 V7.30 has been successfully tested with up to 200 devices in one
project. Depending on the device configuration and the RAM it is possible
to work with even more devices, but this is not tested.

2. Print

Situation When printing a complete project with over 100 devices DIGSI requires up
to 50GB hard disk space on drive C:\, otherwise it will crash.

Solution Make disk space available or print single devices.

3. Project conversion

Situation When trying to upgrade a project which has been created with DIGSI 5
V3.00 or earlier, an error message related to an invalid path name is
displayed.

Solution Due to technical limitations, it is not possible to directly upgrade projects


created with DIGSI 5 V3.00 or earlier versions to DIGSI 5 V6.00 or higher.

In order to open such a project, you must first perform an upgrade with
DIGSI 5 V4.00 or V5.00. After successful upgrade to one these versions,
you can open and upgrade the same project with DIGSI 5 V6.00 or higher.

4. Multiple receiving of GOOSE messages

Situation A GOOSE signal can only be received in one logical node per device.

5. GOOSE messages in different subnetworks

Situation It is only possible to send GOOSE messages over subnetworks to which


all devices are connected which shall receive these messages.

When importing SCL files this restriction is also valid. In some cases
GOOSE messages will be deleted from single subnetworks.

6. USB connection

Situation If the USB connection fails and you receive the error message Unable to
connect to device via USB. Check the connection and network
settings and try again, there is an IP-address conflict.

Solution Follow the general hints for the network configuration described in chapter
4.1 Software Environment. After solving the address conflict, reconnect
your device.

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 21
7. USB connection to devices with firmware version V3.00 or earlier (for example
7ST85)

Situation The SIPROTEC 5 device is connected to the PC via USB but the entry
SIPROTEC 5 devices connected via USB is not visible in the DIGSI 5
Online access area.
In addition, the Initialize device context menu item for the respective
offline device is disabled.

Solution Close DIGSI 5 and download the USB device driver package named
DIGSI_5_USB_DRIVER_RNDIS.zip from the DIGSI 5 product internet
site (http://www.siemens.com/digsi5). Follow the steps described in the
enclosed document to install the USB device driver.
After opening DIGSI 5 again, the entry SIPROTEC 5 devices connected
via USB is now visible in the Online access area of the project tree. In
addition, the Initialize device context menu item for the respective offline
device is enabled.

8. Offline function chart (CFC) analysis (debugging)

Situation If you receive the error message Simulation environment for offline
analysis of function charts (CFC) is started in unknown mode. Try
again., the reason might be an IP-address conflict.

Solution Follow the general hints for the network configuration described in chapter
4.1 Software Environment. After solving the address conflict you have to
configure the IP address of the network adaptor S2010_vHub manually:
IP Address: 192.168.100.100
Subnet mask: 255.255.255.0

9. Device upgrade

Situation Depending on the changes between two versions, a device upgrade can
/Solution lead to inconsistencies that require manual adaptation afterwards.
After upgrade check the configuration of subnets, network redundancy
protocols and user defined labels for LEDs.

10. Scan for accessible devices under Windows 2008 R2 Standard

Situation This problem occurs only under Windows Server 2008 R2 64-bit standard
edition!
If you scan for accessible devices via the main menu/toolbar button and
you have connected more than 5 devices via Ethernet, DIGSI 5 may not
find any device.

Solution In this particular case scan for devices only via the network adapters
under Online access in the Project tree.

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 22
11. Import from older DIGSI 5 versions

Situation Not all files (scd, dex, teax) that were exported with a previous version of
DIGSI 5 can be imported into DIGSI 5 V7.30.

Solution If you need to exchange data from an older DIGSI 5 project into a DIGSI 5
V7.30 project, first convert the older DIGSI 5 project to V7.30 and then
export the file again. Afterwards you can import it into any other DIGSI 5
V7.30 project.

12. Function group Analog Units

Situation If the corresponding hardware is configured, the function group Analog


units is created automatically by DIGSI 5.

This function group can only be deleted if it does not contain any functions
and if the SUP protocol (Serial / Ethernet) has not been selected as
communication protocol in the Hardware and protocols editor.

13. DIGSI 5 Installation

Situation On one machine, the installation of the Prerequisites failed during


DIGSI 5 setup.

Solution If you face this problem, check if the Windows Update Service is running
on your machine. This service is sometimes required for the installation.

14. Saving Devices as Master Copies in User-Defined Libraries

Situation It is not possible to save a device in a user-defined library in order to use


this device as a master copy.

Solution By default, user-defined libraries are opened with activated write


protection. To change this default setting, close the corresponding library.
Deactivate the option Open as read-only in the Open global library
dialog before opening the library again.

15. Displaying User-Defined Function Blocks in the IEC 61850 Structure Editor

Situation A user-defined function block is not displayed correctly in the IEC 61850
Structure Editor in the SIPROTEC 4 similar view.

Solution In the IEC 61850 Structure Editor, use the corresponding list box to switch
to the SIPROTEC 5 view and then, switch back to the SIPROTEC 4 similar
view.

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 23
16. Adding devices with CPU type CP200

Situation Devices equipped with the CPU type CP200 according to the product
code cannot be added in the Devices and networks editor via drag and
drop from the hardware catalog.

When trying to add such a device, the Add new device dialog doesnt
show any application templates in the respective selection list and the OK
button remains deactivated.

Solution Select Add new device in the project tree and enter the short or long
product code of the device in the following dialog. After adding the device
to the project, the CPU type will be displayed in the Device information of
the project tree.

17. Changing the IP address of a COM module

Situation After changing the IP address of a COM module, for example


ETH-BA-2EL, via the editor Devices and networks and loading the
configuration to the device, the respective COM module is not responding
and cannot be reached over the network using ICMP Echo Requests
(Ping).

Solution Perform a manual restart of the device by means of a power cycle


(switching the device off and on). Alternatively, a manual restart can also
be triggered via the Device information editor in DIGSI 5 or directly from
the device HMI.

8 Support
For questions about DIGSI 5, please contact the Siemens Customer Support Center.

Fon: +49 (0) 180 524 7000


Fax: +49 (0) 180 524 2471

E-mail: [email protected]
Internet: http://www.siemens.com/energy-support

DIGSI 5 - Product Information


C53000-X5050-C001-C, Release 06/2016 24
DIGSI 5
V7.30

Produktinformation

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 1
Hinweis
Diese Produktinformation enthlt wichtige Informationen zu DIGSI 5 V7.30.
Sie ist Bestandteil des gelieferten Produkts. Im Zweifelsfall hat diese
Produktinformation Gltigkeit vor allen anderen Informationen.

Haftungsausschluss Copyright
Dieses Dokument wurde vor seiner Herausgabe einer Copyright Siemens AG 2016.
sorgfltigen technischen Prfung unterzogen. Es wird in Alle Rechte vorbehalten.
regelmigen Abstnden berarbeitet und entsprechende
nderungen und Ergnzungen sind in den nachfolgenden Weitergabe sowie Vervielfltigung, Verbreitung und
Ausgaben enthalten. Der Inhalt dieses Dokuments wurde Bearbeitung dieses Dokuments, Verwertung und
ausschlielich fr Informationszwecke konzipiert. Obwohl Mitteilung des Inhaltes sind unzulssig, soweit nicht
die Siemens AG sich bemht hat, das Dokument so schriftlich gestattet. Alle Rechte fr den Fall der
przise und aktuell wie mglich zu halten, bernimmt die Patenterteilung, Geschmacks- oder
Siemens AG keine Haftung fr Mngel und Schden, die Gebrauchsmustereintragung sind vorbehalten.
durch die Nutzung der hierin enthaltenen Informationen
entstehen.

Eingetragene Marken
Diese Inhalte werden weder Teil eines Vertrags oder einer
Geschftsbeziehung noch ndern sie diese ab. Alle SIPROTEC, DIGSI, SIGUARD, SIMEAS und SICAM sind
eingetragene Marken der Siemens AG. Jede nicht
Verpflichtungen der Siemens AG gehen aus den
entsprechenden vertraglichen Vereinbarungen hervor. autorisierte Verwendung ist unzulssig. Alle anderen
Bezeichnungen in diesem Dokument knnen Marken sein,
Die Siemens AG behlt sich das Recht vor, dieses deren Verwendung durch Dritte zu eigenen Zwecken die
Dokument von Zeit zu Zeit zu ndern. Rechte des Inhabers verletzen kann.

Dokumentversion C53000-X5050-C001-C.00
Ausgabe 06/2016

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 2
Inhaltsverzeichnis
1 Lieferumfang ...................................................................................................... 5

2 Open Source Software ...................................................................................... 6

3 Hardware-Voraussetzungen ............................................................................. 7

4 Software-Voraussetzungen .............................................................................. 8

5 Installation ........................................................................................................ 12

6 Benutzungshinweise ....................................................................................... 19

7 Produktmerkmale ............................................................................................ 19

8 Support ............................................................................................................. 24

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 3
DIGSI 5 V7.30
Lieber Kunde,

mit dieser DVD-ROM erhalten Sie DIGSI 5, das PC-Programm zur Konfiguration,
Parametrierung und Bedienung von SIPROTEC 5 Schutz-, Kombi- und Feldgerte, in der
aktuellen Version V7.30.

ber einen PC oder Notebook knnen Sie die Gerte ber die Schnittstellen parametrieren
und die Strfalldaten exportieren. DIGSI 5 ist in verschiedenen Varianten (Compact,
Standard und Premium) mit unterschiedlichen Funktionalitten verfgbar. Welche Variante
den bentigten Funktionsumfang bereitstellt entnehmen Sie bitte dem Katalog:

Mit dem Single-Line-Editor knnen Sie eine Unterstation und die Primrtechnik
grafisch definieren. Verbinden Sie diese Elemente mit den Schutzfunktionen Ihrer
Schutzgerte.
Die grafische Anzeige der SIPROTEC-Gerte kann mit dem Display-Editor oder mit
einem Grafikprogramm gestaltet und bearbeitet werden. Nehmen Sie Ihr
Single-Line-Diagramm und wandeln Sie es in ein Displaybild um. Sie knnen auch
eigene Symbole definieren.
Zustzliche Funktionen, wie beispielsweise die Verriegelung der Gerte, knnen Sie
grafisch mit dem CFC-Editor projektieren.
Mit dem Siemens IEC 61850 Systemkonfigurator knnen Sie IEC 61850-Stationen
konfigurieren und parametrieren. Mit diesem Tool verwalten Sie Subnetze,
Netzteilnehmer und ihre IP-Adressen und verknpfen die Informationen verschiedener
Teilnehmer.
Die DIGSI 5 Test Suite bietet umfangreiche Testwerkzeuge, die Ihre
Inbetriebnahmephase beschleunigen und Sie bei der Bedienung untersttzen. Mit
einer der Testfunktionen knnen Sie Prfablufe erstellen und ausfhren, um Gerte
ohne externe Prfmittel zu prfen.
SIGRA 4 zur einfachen, schnellen und komfortablen Analyse von Strschrieben, wie
sie beispielsweise bei Strfllen in Kraftwerken von Strschreibern aufgezeichnet
werden.

Fr DIGSI 5 sind folgende Sprachen verfgbar: Englisch, Deutsch, Franzsisch,


Portugiesisch, Spanisch, Trkisch, Russisch und Italienisch.

Zur Nutzung von DIGSI 5 Standard und Premium bentigen Sie einen Lizenzschlssel fr
jeden Rechner, auf dem Sie mit DIGSI 5 arbeiten mchten. Wenn Sie die Software ohne
Lizenzschlssel ausfhren, ist sie immer als DIGSI 5 Compact-Edition oder als 30 Tage
gltige Testversion verfgbar.

Alle anderen Lizenzen werden auf USB-Sticks bereitgestellt. Der Umgang mit den
Lizenzschlsseln wird in Kapitel 5.4 beschrieben.

Installationshinweise
Die Installationshinweise enthalten wichtige Informationen, die Sie fr die Installation
von DIGSI 5 bentigen. Lesen Sie diese Hinweise bitte vor Installation der Software.

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 4
1 Lieferumfang
1.1 Inhalt und Struktur des Produkts

DVD DIGSI 5 V7.30 Operating Program for SIPROTEC Devices

DIGSI 5 V7.30 in allen Varianten inklusive IEC 61850 Systemkonfigurator zur


Parametrierung von SIPROTEC 5-Schutzgerten
Optionspaket SIGRA (siehe Produktinformation SIGRA)
IEC 61850-Browser zur Darstellung von Dateien gem IEC 61850
Demoversion des GOOSE Inspectors (Tool zur Analyse des
GOOSE-Netzwerkverkehrs)

DVD DIGSI Device Drivers and Manuals

Alle bis 06/2016 freigegebenen Gertetreiber.


Alle bis 06/2016 freigegebenen Handbcher.

DVD SIPROTEC 5- und DIGSI 5-Tutorial

Umfangreiches Videotutorial, in dem die Funktionen und Merkmale von SIPROTEC 5 und
DIGSI 5 vorgestellt werden, um so einen einfachen Start mit den Gerten und deren
Parametrierung zu ermglichen.

Inhalt und Struktur der Download-Version

Der Inhalt der Download-Version entspricht dem Inhalt der DVD DIGSI 5 V7.30, jedoch
ohne IEC 61850 Browser und GOOSE Inspector.
Sie knnen die Download-Version nur verwenden, um eine frhere DIGSI 5- Installation zu
aktualisieren. Auf einem Rechner ohne frhere DIGSI 5-Installation ist diese Version nicht
ablauffhig.

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 5
2 Open Source Software
Dieses Produkt beinhaltet unter anderem auch Open Source Software, die von Dritten
entwickelt wurde. Die in diesem Produkt enthaltene Open Source Software und die
entsprechenden Open-Source-Software-Lizenzbedingungen finden Sie in der
Readme_OSS.

Die Open-Source-Software-Programme sind urheberrechtlich geschtzt. Sie sind


berechtigt, die Open Source Software gem den jeweiligen
Open-Source-Software-Lizenzbedingungen zu nutzen. Bei Widersprchen zwischen den
Open-Source-Software-Lizenzbedingungen und den fr das Produkt geltenden Siemens
Lizenzbedingungen gelten in Bezug auf die Open Source Software die
Open-Source-Software-Lizenzbedingungen vorrangig.

Die Open Source Software wird unentgeltlich berlassen. Den Quelltext der Software
knnen Sie soweit die einschlgigen Open-Source-Software-Lizenzbedingungen dies
vorsehen gegen Zahlung der Versandkosten bei Ihrem Siemens Vertriebsbeauftragten
zumindest bis zum Ablauf von 3 Jahren ab Erwerb des Produkts anfordern. Wir haften fr
das Produkt einschlielich der darin enthaltenen Open Source Software entsprechend den
fr das Produkt gltigen Lizenzbedingungen. Jegliche Haftung fr die Nutzung der Open
Source Software ber den von uns fr das Produkt vorgesehenen Programmablauf hinaus
sowie jegliche Haftung fr Mngel, die durch nderungen der Open Source Software
verursacht wurden, ist ausgeschlossen. Wir leisten keine technische Untersttzung fr das
Produkt, wenn dieses gendert wurde.

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 6
3 Hardware-Voraussetzungen
Um mit DIGSI 5 V7.30 zu arbeiten, bentigen Sie einen PC oder Notebook mit den
folgenden Mindestvoraussetzungen, die unabhngig von der Version des verwendeten
Betriebssystems sind:

Intel Celeron Dual Core 2,2 GHz (Ivy/Sandy Bridge)


5 GB freier Festplattenspeicher (Empfehlung: Solid State Disk (SSD))
4 GB RAM (Empfehlung: 8 GB)
Grafik-Display HD Ready 1280 x 1024 oder 1376 x 768 Pixel
DVD-ROM-Laufwerk
Tastatur und Maus
USB-Port

Wenn Sie umfangreiche Projekte mit z.B. mehreren Schutzgerten bearbeiten, empfiehlt
Siemens den Einsatz eines Rechners mit der zurzeit gngigen Leistungsfhigkeit.

Hinweis
Wenn Sie DIGSI 5 auf einem Notebook mit Energie-Management verwenden,
empfiehlt Siemens, DIGSI 5 auf diesem Notebook zu verwenden, whrend es an eine
Steckdose angeschlossen ist. Damit wird ein Stromabfall durch Energiesparmodi des
Notebooks im Akkubetrieb vermieden.

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 7
4 Software-Voraussetzungen
4.1 Ablaufumgebung

Betriebssysteme

Die Funktionalitt der Applikation DIGSI 5 V7.30 ist speziell fr die folgenden
Betriebssysteme ausgelegt:

Microsoft Windows 7 Enterprise/Ultimate und Professional 32-Bit und 64-Bit mit


Service Pack 1
Microsoft Windows 8.1 64-Bit
Microsoft Windows Server 2012 R2 64-Bit mit Service Pack 1 als Arbeitsplatzrechner
VMWare-Support fr virtuelle Maschinen (nhere Informationen finden Sie in der
folgenden Liste)
Siemens empfiehlt die Verwendung von 64-Bit Betriebssystemen!

DIGSI 5 V7.30 wurde nicht fr folgende Betriebssysteme getestet:

Microsoft Windows 8.0 32-Bit und 64-Bit


Microsoft Windows 8.1 32-Bit
Microsoft Windows Server 2012 als Arbeitsplatzrechner
Microsoft Windows Server 2008 R2 mit Service Pack als Arbeitsplatzrechner
Der Einsatz dieser Betriebssysteme mit DIGSI 5 V7.30 erfolgt auf eigene Verantwortung.

DIGSI 5 V7.30 ist nicht installierbar und somit nicht ablauffhig unter:

Microsoft Windows XP und ltere Microsoft Betriebssysteme


Microsoft Windows 7 ohne Service Pack, Starter, Home Basic, Home Premium
Microsoft Windows Server 2003, 2008 und 2008 R2 ohne Service Pack
Microsoft Windows 10

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 8
Virtuelle Maschinen
DIGSI 5 V7.30 untersttzt virtuelle Maschinen der Firma VMWare (weitere Informationen
finden Sie unter http://www.vmware.com).

Die Funktionen der virtuellen Maschine wurden fr die folgenden Betriebssysteme


zugelassen:
Microsoft Windows 7 Ultimate/Enterprise and Professional 32-Bit und 64-Bit mit
Service Pack 1
Microsoft Windows 8.1 64-Bit

Die Leistungsfhigkeit von DIGSI 5 ist bei anderen Betriebssystemen nicht gewhrleistet.
Der Einsatz dieser Betriebssysteme erfolgt auf eigene Verantwortung.

Hinweis
Wenn Sie mehrere Ethernet-Adapter an Ihrem Rechner verwenden, bentigen Sie
VMWare Workstation, um den richtigen Ethernet-Adapter fr den Anschluss von
DIGSI 5 an die Gerte auszuwhlen. Bei nur einem Ethernet-Adapter reicht der
kostenlose VMWare Player aus, um DIGSI 5 zu verwenden.

Netzwerk
DIGSI 5 V7.30 verwendet zur Kommunikation HTTP-Verbindungen. Adresskonflikte und
fehlerhafte Netzwerkeinstellungen knnen diese Kommunikation verhindern. Fr USB und
die Offline-Funktionsplan (CFC)-Analyse (Debugging) werden folgende feste
IP-Adressbnder verwendet:

- USB:
Netzwerkadapter-Name: SIPROTEC 5 devices connected via USB
Adressband: 192.168.2.*
Subnetzmaske: 255.255.255.0

- Offline-Funktionsplan (CFC)-Analyse (Debugging):


Netzwerkadaptername: S2010_vHub
Adressband: 192.168.100.*
Subnetzmaske: 255.255.255.0

Diese Adressbnder drfen auf dem DIGSI-Rechner nicht von einem anderen aktiven
Netzwerkadapter verwendet werden. Andernfalls wird die USB-Verbindung zum Gert
oder die Offline-Funktionsplan (CFC)-Analyse (Debugging) nicht funktionieren.

Proxy-Einstellungen

Wenn Sie einen Proxy verwenden, mssen Sie sicherstellen, dass die im vorherigen
Abschnitt genannten IP-Adressbnder als Ausnahme in den Proxy-Einstellungen
eingetragen sind.

Vergewissern Sie sich, dass die Proxy-Einstellungen zu Ihrer Netzwerkkonfiguration


passen. Bei weiteren Fragen wenden Sie sich an Ihren Netzwerkadministrator.

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 9
4.2 Kompatibilitt mit anderer Software

DIGSI 5

Projekte, die mit DIGSI 5 Versionen kleiner V3.00 erstellt wurden, werden von DIGSI 5
V7.30 nicht untersttzt.

DIGSI 4

Die Verwendung von DIGSI 5 V7.30 und jeder verfgbaren DIGSI 4-Version auf demselben
System ist mglich.

HINWEIS
Wenn Sie DIGSI 4.82 oder eine frhere Version nach DIGSI 5 installieren, mssen
Sie den neuesten Automation License Manager (ALM) nach der Installation von
DIGSI 4 neu installieren. Das Setup des ALM befindet sich auf der DIGSI 5-DVD im
Verzeichnis \Automation License Manager.

IEC 61850 Systemkonfigurator

DIGSI 5 V7.30 installiert den IEC 61850 Systemkonfigurator in der Version V5.30. Eine
parallele Installation von IEC 61850 Systemkonfigurator-Versionen kleiner V5.00 auf
demselben System ist mglich.

SIGRA

DIGSI 5 V7.30 wird mit SIGRA V4.58 geliefert. Diese Version ist vollstndig mit lteren
SIGRA-Versionen kompatibel.

TOOLBOX II

Die Verwendung von DIGSI 5 V7.30 und TOOLBOX II V4.10 SP1 auf einem System ist
mglich.

SICAM PAS

Die Verwendung von DIGSI 5 V7.30 und SICAM PAS 6.0 SP5 und SICAM PAS 7.0 auf
demselben System ist mglich.

Spectrum PowerCC IMM

Die Verwendung von DIGSI 5 V7.30 und Spectrum PowerCC IMM V4.20 auf einem
System ist mglich.

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 10
STEP7 V5.x

Die Verwendung von DIGSI 5 V7.30 und der Automatisierungssoftware STEP7 V5.x auf
demselben System ist ohne Einschrnkungen mglich.

Virenscanner

Bisher sind keine Unvertrglichkeiten zwischen handelsblichen Virenscanner und


DIGSI 5 V7.30 bekannt. Trend Micro OfficeScan wurde ausfhrlich getestet.

Programme zur Prfung auf Festplattenfehler

Wenn Sie folgende Richtlinien beachten, knnen Programme zur Prfung auf
Festplattenfehler zusammen mit DIGSI 5 V7.30 verwendet werden.
Der Lizenzschlssel ist auf dem Ziellaufwerk mit einem speziell gekennzeichneten Cluster
verbunden. Einige Programme zur Prfung auf Festplattenfehler zeigen diesen Cluster als
Defekt an. Versuchen Sie nicht, diesen Cluster wiederherzustellen.

Programme zur Defragmentierung der Festplatte

Programme zur Defragmentierung der Festplatte knnen zusammen mit DIGSI 5 V7.30
verwendet werden, wenn Sie folgende Richtlinien beachten:
Wenn Sie ein Programm zur Defragmentierung der Festplatte verwenden, mit dem nicht
verschiebbare Blcke verschoben werden knnen, knnen Sie diese Option nur einsetzen,
wenn Sie den Lizenzschlssel von Ihrer Festplatte zurck auf den Stick mit der Lizenz
bertragen haben. Diese Option fhrt sonst zur Zerstrung der Lizenzdatei.

Rational ClearCase

DIGSI 5 V7.30-Projekte drfen nicht auf ClearCase-Laufwerken (Laufwerke, die mit einer
ClearCase-View verbunden sind (MVFS)) gespeichert werden.

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 11
5 Installation
5.1 Allgemeine Installationshinweise

HINWEIS
Bercksichtigen Sie Folgendes vor der Installation von DIGSI 5 V7.30
Um existierende Projekte mit einer Version 5.xx oder kleiner, die eine IEC
61850-Konfiguration enthalten, auf V7.xx hochzursten, mssen zwingend einige
Schritte befolgt werden. Diese Schritte sind im Dokument
Readme_DIGSI_5_Upgrade_Guideline.pdf beschrieben. Lesen Sie diese
Anleitung sorgfltig, bevor Sie DIGSI 5 V7.30 installieren und befolgen Sie die
Schritte! Sie finden die Anleitung auf der DIGSI 5 V7.30 DVD oder im Internet
(http://www.siemens.de/digsi).

HINWEIS
Fr die Installation von DIGSI 5 sind Administratorrechte erforderlich.

Wenn Sie Windows 7 verwenden, empfiehlt Siemens, DIGSI 5 nicht in das


Wurzelverzeichnis eines Laufwerks zu installieren.

Wenn Sie Windows 7 mit der Sprachoption Chinesisch verwenden, empfiehlt Siemens,
DIGSI in das whrend der Installation vorgeschlagene Verzeichnis zu installieren
(gegebenenfalls auf einem anderen Laufwerk).

Zur optimalen Darstellung der Informationen whrend des Setups empfiehlt Siemens, die
Farbpalette in der Systemsteuerung Ihres Rechners auf mindestens 65 536 Farben
einzustellen.

Schlieen Sie vor dem Starten des Installationsprogramms alle Anwendungen (wie zum
Beispiel MS Word), da Ihr Rechner nach der Installation von DIGSI 5 neu gestartet werden
muss.

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 12
5.2 Installation der Download-Version ber eine existierende
DIGSI 5-Installation
Schlieen Sie DIGSI 5, bevor Sie mit der DIGSI 5 V7.30 Installation beginnen.
Entpacken Sie die Dateien in einen lokalen Ordner auf Ihrem Rechner. Behalten Sie
dabei die Verzeichnisstruktur wie im ZIP-Archiv vorgegeben bei.
Fhren Sie das Installationsprogramm Setup.exe aus. Dieses Programm installiert
DIGSI 5 V7.30 ber Ihre ltere DIGSI 5-Installation.
Whrend des Setups wird auch ein neuer USB-Treiber installiert. Besttigen Sie
etwaig angezeigte Dialoge mit Installieren.
Nachdem die Installation abgeschlossen ist und der Rechner neu gestartet wurde,
knnen Sie die entpackten Dateien des ZIP-Archivs lschen.

5.3 Installation von DIGSI 5 von DVD


Legen Sie die DIGSI 5-DVD mit der Beschriftung DIGSI 5 V7.30 Operating Program for
SIPROTEC Devices in das Laufwerk ein. Die Installation von DIGSI 5 erfolgt ber ein
benutzergefhrtes Setup. Das Installationsprogramm startet automatisch nach dem
Einlegen der DIGSI 5-DVD. Wenn Sie die Autorun-Funktion auf Ihrem Rechner deaktiviert
haben, starten Sie das Installationsprogramm mit dem Microsoft Windows Explorer, indem
Sie auf SETUP.EXE im Wurzelverzeichnis Ihres DVD-Laufwerks doppelklicken.

Folgen Sie den Anweisungen des Installationsprogramms auf dem Bildschirm:

Alle Varianten von DIGSI 5 mit allen bentigten Komponenten werden auf dem System
installiert. Fr die Installation wird kein Lizenzschlssel bentigt (dieser wird beim
ersten Start der Applikation DIGSI 5 abgefragt).
Whlen Sie den Installationspfad fr DIGSI 5. Der empfohlene Installationspfad lautet
C:\Program Files\Siemens Energy\DIGSI 5 V7.30.
Das Laufwerk, auf dem Sie DIGSI 5 installieren, kann frei gewhlt werden. Es muss
ausreichend Festplattenspeicher verfgbar sein.
Whlen Sie eine lokale Festplatte als Ziel fr die Installation aus. DIGSI 5 kann nicht
auf Netzlaufwerken installiert werden.
Wenn Sie den vorgeschlagenen Installationspfad ndern mchten, stellen Sie sicher,
dass die Installation nicht direkt in das Wurzelverzeichnis (z.B. D:) Ihrer Festplatte
erfolgt. Sie sollten mindestens ein Unterverzeichnis beibehalten, wie z.B. DIGSI 5.
Installieren Sie DIGSI 5 nicht in einem Verzeichnis, dessen Pfad Nicht-ASCII-Zeichen
enthlt.
Klicken Sie auf Installieren, um die Installation zu starten.
Whrend des Setups wird auch ein neuer USB-Treiber installiert. Besttigen Sie
etwaig angezeigte Dialoge mit Installieren.
Abhngig von den installierten Komponenten ist mglicherweise ein Neustart des
Systems erforderlich, der vom Installationsprogramm veranlasst wird.
Starten Sie DIGSI 5 aus dem Startmen heraus. Whlen Sie Start > Siemens Energy >
DIGSI 5 V7.30 > DIGSI 5 V7.30.

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 13
5.4 Installation der DIGSI 5-Lizenz

Allgemeine Informationen zu DIGSI 5-Lizenzen

Mit jeder bestellten Lizenz kann DIGSI 5 auf einem System verwendet werden. DIGSI 5
kann mit Lizenzpaketen von 1, 5 oder 10 Lizenzen pro Paket bestellt werden. Damit kann
DIGSI 5 auf 1, 5 oder 10 Systemen gleichzeitig verwendet werden.

Fr DIGSI 5 Standard und DIGSI 5 Premium stehen verschiedene Lizenzen zur Verfgung,
die verschiedene Funktionsumfnge von DIGSI 5 bereitstellen. Des Weiteren gibt es
Optionspakete als Ergnzung zu DIGSI 5 Standard, zum Beispiel SIGRA. Diese
Optionspakete werden ebenfalls mit Lizenzschlsseln ausgeliefert, die diese Funktionen in
DIGSI 5 verfgbar machen.

DIGSI 5-Lizenzen werden auf USB-Sticks ausgeliefert. Die Lizenz wird unter Verwendung
des Automation License Managers (ALM) auf ein System bertragen. Das nchste Kapitel
gibt eine kurze Einfhrung zur bertragung von Lizenzen mit dem Automation License
Manager.

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 14
Installieren von DIGSI 5-Lizenzen

HINWEIS
Die installierten Lizenzen knnen durch die Verwendung inkompatibler Virenscanner
oder nicht kompatibler Programme zur Defragmentierung der Festplatte zerstrt
werden. Nhere Informationen zur Kompatibilitt mit anderer Software finden Sie in
Kapitel 4.2.

Im Fall einer beschdigten Lizenz wenden Sie sich bitte an die Siemens-Hotline
(http://support.automation.siemens.com/WW/view/de/772175) und halten Sie
entweder Ihr Lizenzzertifikat oder Ihren USB-Stick mit der Lizenz bereit, um der
Hotline die zur Wiederherstellung der Lizenz erforderlichen Informationen zu geben.

Jeder USB-Stick enthlt eine bestimmte Anzahl an Emergency-Lizenzen, die im Fall


einer beschdigten Lizenz verwendet werden knnen und mit denen 14 Tage lang
weitergearbeitet werden kann. Installieren Sie die Emergency-Lizenz bei Bedarf von
Ihrem USB-Stick, whrend die Hotline Ihr Lizenzproblem bearbeitet. Verwenden Sie
die Emergency-Lizenz jedoch nur in diesem Fall.

Jedes Mal, wenn DIGSI 5 startet und feststellt, dass bisher kein Lizenzschlssel installiert
wurde, stehen mehrere Optionen zur Auswahl:

1. Installieren Sie einen Lizenzschlssel fr DIGSI 5 Standard oder DIGSI 5 Premium.

2. Fhren Sie das Programm als DIGSI 5 Compact aus, wobei ein sehr beschrnkter
Funktionsumfang zur Verfgung steht.

3. Starten Sie eine Trial-Phase, whrend der Sie DIGSI 5 Premium 30 Tage lang im
Trial-Modus auf Ihrem System nutzen knnen. Nach 30 Tagen bentigen Sie
entweder einen gltigen Lizenzschlssel fr DIGSI 5 Standard oder DIGSI 5
Premium, um weiterarbeiten zu knnen oder Sie verwenden DIGSI 5 Compact.
Bitte beachten Sie, dass DIGSI 5 Compact nicht den gesamten Funktionsumfang
bereitstellt, den Sie mglicherweise beim Einsatz von DIGSI 5 Premium Trial
verwendet haben.

Eine detaillierte Liste mit dem Funktionsumfang der verschiedenen DIGSI 5-Varianten
finden Sie im SIPROTEC 5-Katalog. Damit knnen Sie die fr Ihre Zwecke geeignete
DIGSI 5-Variante auswhlen.

Wenn Sie sich fr die Installation eines Lizenzschlssels entscheiden, startet der
Automation License Manager und erlaubt Ihnen die Installation eines Lizenzschlssels,
whrend DIGSI 5 darauf wartet, dass Sie wieder zu DIGSI 5 zurckkehren.

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 15
Installation von Lizenzen vom USB-Stick

Zur Installation eines Lizenzschlssels stecken Sie den im Lieferumfang von DIGSI 5
enthaltenen USB-Stick einfach in einen USB-Port Ihres Rechners.

Der USB-Stick wird sofort erkannt und vom Automation License Manager angezeigt.

Whlen Sie im linken Baum den USB-Stick mit Ihren Lizenzen aus. Die Liste der
verfgbaren Lizenzen wird rechts im Automation License Manager angezeigt.

1. Markieren Sie die entsprechende Lizenz mit der Maus.


2. Drcken Sie die rechte Maustaste, um das Kontextmen anzuzeigen. Whlen Sie
Transfer
3. Whlen Sie im angezeigten Dialog eine Ihrer lokalen Festplatten aus.
4. Klicken Sie auf OK, um die Lizenz auf Ihre Festplatte zu bertragen.
5. Schlieen Sie den Automation License Manager und kehren Sie zum Fenster von
DIGSI 5 zurck.

Installation von Lizenzen ber das Netzwerk

ber eine Netzwerkverbindung knnen Sie Lizenzen von einem anderen Rechner
bertragen.
1. Klicken Sie im Men Edit im Automatic License Manager auf Connect Computer.
2. Tragen Sie unter Computer Name den Namen eines Rechners im Netzwerk ein
oder whlen Sie einen Namen aus der Auswahlliste aus.
Klicken Sie auf Browse, um nach einem Rechner im Netzwerk zu suchen.
3. Klicken Sie auf OK zur Besttigung.

Der Rechner wurde im Navigationsbereich hinzugefgt. Um eine Lizenz auf Ihrem Rechner
zu bertragen, fhren Sie bitte die im Kapitel Installation von Lizenzen vom USB-Stick
beschriebenen Schritte 1 bis 5 aus.

HINWEIS
Bei Verbindungsfehlern berprfen Sie bitte die Symbolleiste Settings im
Datei-Men. Hier knnen Sie festlegen, ob die bertragung von Lizenzen von Ihrem
Rechner oder auf Ihren Rechner erlaubt sein soll oder nicht. Weitere Hilfe finden Sie
im Men Hilfe.

HINWEIS
Es gibt verschiedene andere Wege, Lizenzen zwischen Systemen zu bertragen.
Das Men Hilfe des Automation License Managers enthlt eine Beschreibung der
weiteren Mglichkeiten (vor allem: Arbeiten mit dem Automation License Manager
License Keys im Netz nutzen / Access Protection for Automation License Manager).

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 16
Upgrade von DIGSI 5 Standard auf DIGSI 5 Premium

ber eine Upgrade-Lizenz knnen Sie mithilfe des Automation License Managers ein
Upgrade der Lizenz von DIGSI 5 Standard auf DIGSI 5 Premium durchfhren.
1. Kopieren Sie die Upgrade-Lizenz vom USB-Stick auf die lokale Festplatte (siehe
Kapitel Installation von Lizenzen vom USB-Stick).

2. Whlen Sie die Lizenz, fr die Sie ein Upgrade mchten.

3. Whlen Sie License Keys in der Menleiste und anschlieend Upgrade.

Wenn es nur eine Mglichkeit zum Upgrade gibt, wird diese ohne weitere Meldungen und
Eingabeaufforderungen ausgefhrt.
Wenn es mehrere Mglichkeiten zum Upgrade gibt, ffnet sich der Dialog License Key
Upgrade:
Whlen Sie das gewnschte Upgrade und klicken Sie auf die Schaltflche
Upgrade.

Probleme mit verlorenen und beschdigten Lizenzen

Wenn Sie das Problem haben, dass die Lizenz(en) von DIGSI 5 oder SIGRA nicht
gefunden werden, gehen Sie zur Log-Ansicht des Automation License Managers (ALM),
um festzustellen, ob jemand Ihre Lizenz(en) von Ihrem Rechner entfernt hat:

1. Klicken Sie im Automation License Manager auf View Log.

2. Whlen Sie auf der linken Seite einen angemessenen Zeitraum aus, zum Beispiel
Last 100 entries.

3. Auf der rechten Seite werden die bisherigen Lizenzbertragungen von, zu und auf
Ihrem Rechner angezeigt.

Wenn das Problem nicht behoben werden kann, wenden Sie sich bitte an die
Siemens-Hotline (http://support.automation.siemens.com/WW/view/de/772175). Halten
Sie entweder Ihr Lizenzzertifikat oder Ihren USB-Stick mit der Lizenz bereit, um der Hotline
die zur Wiederherstellung der Lizenz erforderlichen Informationen zu geben.

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 17
5.5 Installation der DIGSI-Gertetreiber
Um mit SIPROTEC 5-Gerten zu arbeiten, bentigt DIGSI 5 Gertetreiber (DIGSI Device
Driver). Diese Gertetreiber befinden sich auf der DVD mit der Beschriftung DIGSI Device
Drivers and Manuals.

Nach dem Start prft DIGSI 5, ob Sie bereits Gertetreiber installiert haben. Wenn nicht,
fordert Sie DIGSI 5 nun dazu auf und fhrt Sie direkt zum Installationsdialog.

HINWEIS
Wenn Sie zu einem spteren Zeitpunkt weitere Gertetreiber hinzufgen mchten,
erreichen Sie den Dialog fr die Installation der Gertetreiber immer ber das
Hauptmen von DIGSI 5 (Werkzeuge > Gertetreiber importieren).

1. Whlen Sie im Dialog Gertetreiber importieren alle Gertetreiberdateien, die in


DIGSI 5 verfgbar sein sollen. Whlen Sie dazu die bentigten *.DDD-Dateien und
klicken Sie auf OK.

2. Die von Ihnen ausgewhlten Gertetreiber werden analysiert und ein Baum mit
den verfgbaren Versionen der Gertetreiber wird angezeigt.

3. Whlen Sie aus dem Baum die Elemente aus, die Sie installieren mchten
(maximal 15 pro Import) und klicken Sie auf Installieren.

4. Um die DIGSI-Gertetreiber zu installieren, muss DIGSI 5 am Ende des Vorgangs


neu gestartet werden. Deshalb wird jedes Projekt gespeichert, geschlossen und
nach dem Neustart von DIGSI 5 wieder geffnet.

Sie knnen nun mit DIGSI 5 arbeiten.

5.6 Deinstallation
Mit dem Deinstallationsprogramm von Windows knnen Sie DIGSI 5 mit allen optionalen
Komponenten von Ihrem Rechner entfernen. Whrend der Deinstallation entfernt das
Installationsprogramm von DIGSI 5 alle installierten Programmdateien. Die
benutzerspezifischen Daten, wie beispielsweise Projekte, bleiben davon unberhrt.

Whlen Sie Systemsteuerung im Windows-Startmen und ffnen Sie Programme >


Programme und Funktionen.

Whlen Sie in der Liste Siemens DIGSI 5 V7.30 aus.

Klicken Sie auf Entfernen, um die Deinstallation zu starten. Folgen Sie den
Installationsanweisungen.

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 18
6 Benutzungshinweise
6.1 Nachbestellung
Wenn Sie nachtrglich Komponenten von DIGSI 5 installieren mchten, die Sie nicht
bestellt haben, knnen Sie diese unter Angabe des Lizenzschlssels bestellen. Sie
erhalten einen neuen Lizenzschlssel, der die zustzlichen Komponenten aktiviert. Eine
Neuinstallation von DIGSI 5 ist nicht erforderlich.

7 Produktmerkmale
Eine Liste der Funktionen von DIGSI 5 finden Sie im SIPROTEC 5-Systemkatalog
(E50001-K4605-A011-A1-7600).

7.1 Neuerungen und nderungen in DIGSI 5 V7.30


1. Untersttzung der neuen SIPROTEC 5 V7.30-Gerteversion
DIGSI 5 V7.30 untersttzt SIPROTEC 5-Gerte in den Versionen V1.xx bis V7.30.
2. Kopieren und Einfgen von Funktionen und Funktionsgruppen
Funktionen und Funktionsgruppen knnen sowohl innerhalb eines Gertes als auch
gertebergreifend kopiert werden.
3. CFC-Teilplne und Vorlagen
CFC-Teilplne knnen erstellt werden, die in anderen CFC-Plnen wiederverwendet
werden knnen, sowohl innerhalb eines Gertes als auch gertebergreifend. Dies fhrt zu
einer deutlich verringerten Komplexitt und erhhten bersichtlichkeit beim Arbeiten mit
groen CFC-Plnen. Darber hinaus ermglicht die Ablage von CFC-Teilplnen in
benutzerdefinierten Bibliotheken auch eine projektbergreifende Wiederverwendung.
4. Trend View/dynamische Werteanzeige fr CFC-Analyse
Die Funktionen zur Offline- und Online-Analyse von CFC-Plnen untersttzen nun die
berwachung von im CFC ausgewhlten Binrsignalen und analogen Signale ber die
Zeit. Um die logischen Ablufe besser zu verdeutlichen und die Fehlersuche in
umfangreichen CFC-Plnen zu vereinfachen, wird der Werteverlauf der einzelnen Signale
dabei grafisch in einem Diagramm angezeigt. Darber hinaus lassen sich die aktuellen
Werte von ausgewhlten CFC-Signalen auch in einer tabellarischen Darstellung
berwachen.
5. Querverweisliste mit CFC-Signalen
Gesamtliste mit allen Signalen, die in einem CFC-Plan im aktuellen Projekt verwendet
werden. Bei Doppelklick auf einen bestimmten Listeneintrag wird der entsprechende
CFC-Plan geffnet und das ausgewhlte Signal hervorgehoben.
6. Schreibschutz-Modus fr CFC-Plne
CFC-Plne knnen ber ein Passwort mit einem Schreibschutz versehen werden.
Entsprechend geschtzte Plne knnen zwar weiterhin angezeigt werden, lassen sich
aber nicht mehr ndern.
7. Verbesserungen beim Gertevergleich
Die Funktion zum Gertevergleich bercksichtigt nun auch Namensunterschiede, zum
Beispiel bei Signal- und Funktionsgruppenbezeichnungen. Des Weiteren wurde die
allgemeine Bedienbarkeit verbessert.

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 19
8. Anzeige des kurzen Produkt-Codes von SIPROTEC 5-Gerten
In der Gerteinformation in DIGSI 5 und auf dem Gerte-HMI wird nun auch der kurze
Produkt-Code angezeigt.
9. Reduzierung der Projektgre in Bezug auf Logs
Bei DIGSI 5-Projekten mit einer groen Anzahl von Log-Dateien konnte die Projektgre
signifikant reduziert werden.
10. Mehrere TEA-X-Erweiterungen und -Verbesserungen
Das XML-basierte Datenaustauschformat TEA-X enthlt nun auch die Informationen aus
dem IEC 61850-Struktureditor. Des Weiteren wurde der TEA-X-Importdialog im Hinblick
auf die Bedienbarkeit grundlegend berarbeitet.
11. Verschiedene andere kleine Verbesserungen und Fehlerbehebungen

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 20
7.2 Bekannte Probleme und Beschrnkungen
1. Anzahl der Gerte

Situation DIGSI 5 V7.30 wurde erfolgreich mit bis zu 200 Gerten in einem Projekt
getestet. Das Arbeiten mit mehr Gerten ist abhngig von
Gertekonfiguration und Arbeitsspeicher mglich, wurde jedoch nicht
getestet.

2. Drucken

Situation Beim Ausdrucken eines kompletten Projekts mit ber 100 Gerten
bentigt DIGSI bis zu 50 GB Festplattenspeicher auf Laufwerk C:\, sonst
strzt das Programm ab.

Lsung Schaffen Sie Speicherplatz oder drucken Sie einzelne Gerte aus.

3. Projektkonvertierung

Situation Beim Versuch ein Projekt hochzursten, das mit DIGSI 5 V3.00 erstellt
wurde, erscheint eine Fehlermeldung mit Hinweis auf eine ungltige
Pfadangabe.

Lsung Projekte, die mit DIGSI 5 V3.00 oder frher erstellt wurden, lassen sich
aus technischen Grnden nicht direkt in DIGSI 5 V6.00 oder hher ffnen
bzw. hochrsten.

Ein solches Projekt mssen Sie zunchst mit DIGSI 5 V4.00 oder V5.00
hochrsten. Im Anschluss knnen Sie das konvertierte Projekt mit DIGSI
5 V6.00 oder hher hochrsten und weiter bearbeiten.

4. Mehrfaches Empfangen von GOOSE Meldungen

Situation Ein GOOSE-Signal kann pro Gert nur in einem Logical Node empfangen
werden.

5. GOOSE Meldungen in verschiedenen Subnetzen

Situation Es ist nur mglich GOOSE-Meldungen ber Subnetzwerke zu


verschicken, mit denen alle Gerte verbunden sind, die die Meldung
empfangen sollen.

Beim Import von SCL Dateien trifft diese Einschrnkung ebenfalls zu und
wird notfalls durch Lschen von GOOSE-Meldungen in einzelnen
Subnetzwerken erzwungen.

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 21
6. USB-Verbindung

Situation Wenn die USB Verbindung fehlschlgt und Sie die Fehlermeldung
Verbindung zum Gert ber USB konnte nicht aufgebaut werden.
Prfen Sie die Verbindung und die Netzwerkeinstellungen und
versuchen Sie es erneut. erhalten, liegt ein IP-Adresskonflikt vor.

Lsung Beachten Sie die Hinweise zur Netzwerkkonfiguration im Kapitel 4.1


Ablaufumgebung. Nach Auflsen des IP-Adresskonfliktes verbinden Sie
das Gert neu.

7. USB-Verbindung zu Gerten mit Firmware-Version V3.00 oder frher (z.B. 7ST85)

Situation Obwohl das SIPROTEC 5-Gert ber USB mit dem PC verbunden ist,
wird der Eintrag SIPROTEC 5-Gerte ber USB verbunden im Bereich
Online-Zugnge der Projektnavigation nicht angezeigt. Darber hinaus
ist der Eintrag Gert initialisieren im Kontextmen des entsprechenden
Offline-Gertes deaktiviert.

Lsung Schlieen Sie DIGSI 5 und laden Sie den USB-Gertetreiber mit dem
Namen DIGSI_5_USB_DRIVER_RNDIS.zip von der DIGSI 5
Produktseite im Internet (http://www.siemens.com/digsi5). Beachten Sie
die notwendigen Schritte zur Installation des USB-Treibers wie im
beiliegenden Dokument beschrieben.
Nach dem erneuten ffnen von DIGSI 5 wird nun der Eintrag SIPROTEC
5-Gerte ber USB verbunden im Bereich Online-Zugnge der
Projektnavigation angezeigt. Darber hinaus ist der Eintrag Gert
initialisieren im Kontextmen des entsprechenden Offline-Gertes
aktiviert.

8. Offline-Funktionsplan (CFC)-Analyse (Debugging)

Situation Wenn whrend der Offline-Funktionsplan (CFC)-Analyse (Debugging) die


Fehlermeldung Die Simulationsumgebung fr die Offline-Analyse der
Funktionsplne (CFC) wurde in unbekanntem Modus gestartet.
Versuchen Sie es erneut. erscheint, kann die Ursachen ein
IP-Adresskonflikt sein.

Lsung Beachten Sie die Hinweise zur Netzwerkkonfiguration im Kapitel 4.1


Ablaufumgebung. Nach Auflsung des Konfliktes muss die IP-Adresse fr
den Netzwerkadapter S2010_vHub manuell konfiguriert werden:
IP-Adresse: 192.168.100.100 Subnetzmaske: 255.255.255.0

9. Gerte-Upgrade

Situation Abhngig von den nderungen zwischen zwei Versionen kann ein
/Lsung Gerte-Upgrade zu Inkonsistenzen fhren, die manuell behoben werden
mssen.
berprfen Sie nach dem Upgrade zustzlich die Konfiguration der
Subnetze, die Netzwerkredundanzprotokolle und benutzerdefinierte
Namen fr LEDs.

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 22
10. Erreichbare Teilnehmer unter Windows 2008 R2 Standard

Situation Dieses Problem tritt nur unter Windows Server 2008 R2 64-bit Standard
auf!
Wenn Sie ber Ethernet zu mehr als 5 Gerten verbunden sind ber das
Hauptmen/Toolbar nach erreichbaren Teilnehmern suchen, kann es
vorkommen, dass DIGSI 5 keines der Gerte findet.

Lsung Verwenden Sie in der beschriebenen Konstellation ausschlielich die


Suche ber die Netzwerkadapter unter Online-Zugnge in der
Projektnavigation, um nach erreichbaren Gerten zu suchen.

11. Import aus lteren DIGSI 5 Versionen

Situation Nicht alle Dateien (scd, dex, teax), die mit einer frheren DIGSI 5 Version
exportiert wurden, lassen sich in DIGSI 5 V7.30 importieren.

Lsung Wenn Sie Daten aus einem lteren DIGSI 5 Projekt in ein DIGSI 5 V7.30
Projekt importieren mssen, konvertieren Sie zuerst das ltere Projekt
nach V7.30 und exportieren Sie die Daten anschlieend erneut. Danach
lsst sich die Datei in jedes DIGSI 5 V7.30 Projekt importieren.

12. Funktionsgruppe FG Analoge Umformer

Situation Die Funktionsgruppe FG Analoge Umformer wird von DIGSI 5


automatisch angelegt, wenn die entsprechende Hardware konfiguriert
wird.
Diese Funktionsgruppe kann nur gelscht werden, wenn sie keine
Funktionen enthlt und das SUP-Protokoll (seriell/Ethernet) im Hardware
und Protokolle Editor nicht als Kommunikationsprotokoll ausgewhlt ist.

13. DIGSI 5 Installation

Situation Auf einem Rechner schlug die Installation der Prerequisites von DIGIS 5
fehl.

Lsung Wenn dieses Problem bei Ihnen auftritt, berprfen Sie, ob der Windows
Update Service luft. Dieser wird teilweise fr die Installation bentigt.

14. Ablage von Gerten als Kopiervorlage in benutzerdefinierten Bibliotheken

Situation Es ist nicht mglich ein Gert zur Verwendung als Kopiervorlage in einer
benutzerdefinierten Bibliothek abzulegen.

Lsung Benutzerdefinierte Bibliotheken werden standardmig mit aktiviertem


Schreibschutz geffnet. Um diese Voreinstellung zu ndern, schlieen
Sie die entsprechende Bibliothek. Deaktivieren vor dem erneuten ffnen
der Bibliotheksdatei die Option Schreibgeschtzt ffnen im Dialog
Globale Bibliothek ffnen.

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 23
15. Anzeige von benutzerdefinierten Funktionsblcken im IEC 61850-Struktureditor

Situation Ein benutzerdefinierter Funktionsblock wird im IEC 61850-Struktureditor


in der SIPROTEC 4-hnlichen Sicht nicht korrekt angezeigt.

Lsung Wechseln Sie im IEC 61850-Struktureditor ber die entsprechende


Auswahlliste zunchst in die SIPROTEC 5-Sicht und dann wieder zurck
in die SIPROTEC 4-hnliche Sicht.

16. Hinzufgen von Gerten mit CPU-Typ CP200

Situation Gerte, die laut Produktcode mit dem CPU-Typ CP200 ausgestattet sind,
knnen im Editor Gerte und Netze nicht per Drag & Drop aus dem
Hardware-Katalog angelegt werden.

Beim Versuch ein solches Gert hinzuzufgen, werden im Dialog Neues


Gert hinzufgen keine Applikationsvorlagen zur Auswahl angezeigt und
die Schaltflche OK bleibt deaktiviert.

Lsung Whlen Sie Neues Gert hinzufgen in der Projektnavigation und geben
Sie im folgenden Dialog den kurzen oder langen Produktcode des
Gertes ein. Nach dem Hinzufgen wird der CPU-Typ in der
Gerteinformation des entsprechenden Gertes angezeigt.

17. nderung der IP-Adresse bei einem Kommunikationsmodul

Situation Nach nderung der IP-Adresse eines Kommunikationsmoduls,


beispielsweise vom Typ ETH-BA-2EL, ber den Editor Gerte und Netze
und anschlieendem Laden der Konfiguration in das Gert, ist das
Kommunikationsmodul nicht mehr im Netzwerk erreichbar (unter anderem
ber Ping).

Lsung Fhren Sie einen manuellen Neustart des betreffenden Gertes durch,
indem Sie es zunchst aus- und dann wieder einschalten. Alternativ
knnen Sie einen Neustart auch ber die Gerteinformation in DIGSI 5
oder direkt ber die Benutzeroberflche am Gert auslsen.

8 Support
Bei Fragen zu DIGSI 5, wenden Sie sich bitte an das Siemens Customer Support Center.

Telefon: +49 (0) 180 524 7000


Fax: +49 (0) 180 524 2471

E-Mail: [email protected]
Internet: http://www.siemens.com/energy-support

DIGSI 5 - Produktinformation
C53000-X5050-C001-C, Freigabe 06/2016 24

You might also like