PFM-42V1 Series Protocol Manual: Preliminary
PFM-42V1 Series Protocol Manual: Preliminary
2. Pin Assignment
Monitor side : D-sub 9pin (Female) Host side : D-sub 9pin (male)
1 NC 1 NC
2 RD 2 RD
3 TD 3 TD
4 NC 4 NC
5 GND 5 GND
6 NC 6 NC
7 NC 7 NC
8 NC 8 NC
9 NC 9 NC
( S t r a i g h t c o n n e c t i on is necessary)
3. Command Table
1. General Function.
(a) Mode Control
Syntax Header Category Function Data1 Data2
[a] (1-a)-[b]
Answer Header Answer Return Data Size Return Data1 Return Data2
Execute Judge 0x70 0x00 Variable Code Table Completed with Enable
(1-a)-[b] Codes
0x01 ON
0x01 Input Select 0x08 MON RGB1 Yes Yes Disable Note Note
0x02 Force Status Display 0x00 OFF Yes Yes Disable Disable Enable
0x01 ON
0x03 Audio Mute 0x00 OFF Yes Yes Disable Disable Enable
0x01 ON
0x04 Auto Status Display 0x00 ON Yes Yes Disable Disable Enable
0x01 OFF
0x05 Closed Caption 0x00 OFF Yes Yes Disable Disable Note
0x01 Caption1
0x02 Caption2
0x03 Text1
0x04 Text2
0x06 Color System 0x00 Auto Yes Yes Disable Disable Note
0x01 NTSC
0x03 PAL
0x04 SECAM
0x05 PAL-M
0x06 PAL-N
0x07 PAL60
0x07 Auto Color System 0x00 NTSC/PAL/SECAM/NTSC443 Yes Yes Disable Disable Note
0x01 NTSC/PAL-M/PAL-N
0x08 Power Saving 0x00 OFF Yes Yes Note Note Note
0x01 ON
0x09 ON/OFF Timer 0x00 OFF Timer Yes Yes Note Note Note
0x01 ON Timer
0x03 OFF
Code table (1-a)
0x0A Timer Repeat 0x00 OFF Yes Yes Enable Enable Enable
0x01 ON
0x0B Picture Inversion 0x00 OFF Yes Yes Note Note Note
0x01 AUTO
0x02 ON
0x0C Picture Orbit 0x00 OFF Yes Yes Enable Enable Enable
0x01 ON
0x0D Orbit Range 0x00 Small Yes Yes Enable Enable Enable
0x01 Middle
0x02 Large
0x0E Orbit Cycle 0x00 10 sec. Yes Yes Enable Enable Enable
0x01 30 sec.
0x02 1 min.
0x03 5 min.
0x01 English
0x02 Deutsch
0x03 Francais
0x04 Espanol
0x05 Italiano
0x10 Index Number 0x01 0xFF Yes Yes Enable Enable Enable
0x01 ON
0x02 OFF
0x12 Remote Only 0x00 OFF Yes Yes Enable Enable Enable
0x01 ON
0x13 Energy Saving 0x00 Standard Yes Yes Enable Enable Enable
0x01 Reduce
0x01 OFF
0x01 1035i
0x17 RGB Mode 0x00 DTV Yes Yes Disable Disable Enable
0x01 PC
0x18 Sync Mode 0x00 H/Comp Yes Yes Disable Disable Enable
0x01 Video
Code table (1-a)
0x19 Menu Key 0x00 On/Off Yes Yes Disable Disable Enable
0x01 Return
0x01 30 min
0x02 60 min
0x03 90 min
0x1B Clock Display 0x00 OFF Yes Yes Enable Enable Enable
0x01 ON
0x01 OFF
0x31 Active Picture 0x00 Left Yes Yes Disable Disable Enable
0x01 Right
0x02 Swap
0x32 Picture Size 0x00 0x0E Yes Yes Disable Disable Enable
(b) Color matrix
Syntax Header Category Function Data1 Data2 Data3
Control 0x8C 0x00 Code Table (1-b)- 0x02 Code Table Code Table
[a] (1-c) (1-b)-[b]
(1-c)
Answer Header Answer Return Data Size Return Data1 Return Data2
0x1D Color Matrix 0x00 YCbCr Yes Yes Disable Enable Enable
0x01 YPbPr
Format Select
0x00 480p
0x01 1080i
0x02 720p
(c) Time control
Syntax Header Category Function Data1 Data2 Data3
(1-c)
Answer Header Answer Return Data Size Return Data1 Return Data2
ON/OFF Timer
Picture Inversion
Time Set
Answer Header Answer Return Data Size Return Data1 Return Data2
Execute Judge 0x70 0x00 Variable (Data Code Table Completed with Enable
Size) (2-a)-[b] Codes
0x04 Color Temp 0x00 Cool Yes Yes Disable Disable Enable
0x01 Neutral
0x02 Warm
0x03 User1
0x04 User2
0x05 User3
0x01 Low
0x02 Mid
0x03 High
Code table (2-a)
0x01 Off
0x0E Gamma Correct 0x00 High Yes Yes Disable Disable Enable
0x01 Mid
0x02 Low
0x10 Picture Mode 0x00 Standard Yes Yes Disable Disable Enable
0x01 Vivid
0x02 User1
0x03 User2
0x04 User3
0x01 Hall
0x02 Simulate
(b) Color temperature
Syntax Header Category Function Data1 Data2 Data3
Control 0x8C 0x10 Code Table (2-b)- 0x02 Code Table Code Table
[a] (2-c) (2-b)-[b]
(2-c)
Answer Header Answer Return Data Size Return Data1 Return Data2
0x05 Red Gain 0x00 0x1E Yes Yes Disable Disable Disable
0x06 Green Gain 0x00 0x1E Yes Yes Disable Disable Disable
0x07 Blue Gain 0x00 0x1E Yes Yes Disable Disable Disable
Format Select
0x03 User1
0x04 User2
0x05 User3
(c) Color temperature name
Syntax Header Category Function Data1 Data2 Data3 to Data8
Control 0x8C 0x10 0x08 0x07 Code Table (2-c) 0x00 0xFF
Temp Select
Temp Select
Control 0x8C 0x20 Code Table (3-a)- 0x02 Code Table Code Table
[a] (3-a)-[b] (3-a)-[b]
Answer Header Answer Return Data Size Return Data1 Return Data2
0x0A H Total Pixel 0x0190 0x09C4 (default +/- 50) Yes Yes Disable Disable Disable
Answer Header Answer Return Data Size Return Data1 Return Data2
(3-b)-[b]
Execute Judge 0x70 0x00 Variable (Data Size) Code Table Command Disable
(3-b)-[b]
0x04 Zoom Mode 0x00 Expd. 4:3 Yes Yes Disable Disable Note
0x02 16:9
0x03 Subtitle
0x04 4:3
0x05 Zoom size 0x00 Standard Yes Yes Disable Disable Note
0x01 X2
0x02 X3
0x03 X4
0x06 Auto Pixel Adjust 0xFF Execute Yes No Disable Disable Enable
0x07 Dot Phase 0x00 0x1F Yes Yes Disable Disable Enable
0x08 Auto Wide 0x00 Off Yes Yes Disable Disable Note
0x01 On
0x09 4:3 Mode 0x00 4:3 Yes Yes Disable Disable Enable
Format Select
0x20 PFM-42V1
Answer Header Answer Return Data Size Return Data1 Return Data2 Return Data3 Return Data4
Enquiry 0x70 0x00 0x04 Upper 8bit Middle Middle Lower 8bit Completed
Data Upper Data Lower Data Data
Answer Header Answer Return Data Size Return Data1 Return Data2 Return Data3 Return Data4
Enquiry 0x70 0x00 0x04 Upper 8bit Middle Middle Lower 8bit Completed
Answer Header Answer Return Data Size Return Data1 Return Data2
Answer Header Answer Return Data Size Return Data1 Return Data2
Control 0x8C 0x40 0x02 0x07 Code Table (5-b) Character Data
(0x00 0xFF)
Memory Number
Normal code
0x01 Limit over The packet was received normally, but the data value was over the upper limit.
Forcedly the monitor adjusted the data to maximum value.
0x02 Limit under The packet was received normally, but the data value was under the lower limit.
Forcedly the monitor adjusted the data to minimum value.
0x03 Command cancelled The packet was received normally, but the command was cancelled because
0x05 Fail The packet was received normally, but the command was cancelled.
Please retry.
Error code
0x00 No function error Packet header, category or function codes do not exist in this protocol.
0x02 Data number error The data value in Data num area of received packet was different from the functions
own number
0x06 Mode error The monitor is already in the service mode via remote commander operation.
(The service mode through IR remote has priority over the serial remote command.)
0x07 Time out Packet communications are interrupted by some error, and did not return to normal
communication within 2 seconds.