0% found this document useful (0 votes)
72 views21 pages

Install Instructions - Cingoli

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 21

Use, Care, and Installation Guide

READ AND SAVE THESE INSTRUCTIONS


EN Contents page 1

English

Contents
Important safety Notice ..............................................................................................................................................3
Electrical & Installation requirements ......................................................................................................................4
Electrical requirements ....................................................................................................................................................................................4
Before installing the hood ................................................................................................................................................................................4
List of Materials...........................................................................................................................................................5
Parts supplied .................................................................................................................................................................................................5
Parts not supplied............................................................................................................................................................................................5
Dimensions and Clearances......................................................................................................................................6
Ducting Options and Examples.................................................................................................................................7
Venting methods .............................................................................................................................................................................................7
Preparation .....................................................................................................................................................................................................7
Installation ...................................................................................................................................................................8
Installation - Ducting version............................................................................................................................................................................8
Installation - Ductless (Recirculating) version ................................................................................................................................................ 12
Description of the hood & Controls ........................................................................................................................16
Controls......................................................................................................................................................................................................... 17
Maintenance ..............................................................................................................................................................19
Cleaning........................................................................................................................................................................................................ 19
Grease Filter ................................................................................................................................................................................................. 19
Replacing the light bulb ................................................................................................................................................................................. 19
Charcoal Filter............................................................................................................................................................................................... 19

APPROVED FOR RESIDENTIAL APPLIANCES


FOR RESIDENTIAL USE ONLY
READ AND SAVE THESE INSTRUCTIONS
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these Instructions for the Local Electrical Inspectors use.
INSTALLER: Please leave these Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
Safety Warning: Turn off power circuit at service panel and lock out panel, before wiring this appliance.
Requirement: 120 V AC, 60 Hz. 15 or 20 A Branch Circuit
READ AND SAVE THESE INSTRUCTIONS
Important safety Notice
CAUTION WARNING
FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO REDUCE THE RISK OF INJURY TO PERSONS, IN
TO EXHAUST HAZARDOUS OR EXPLOSIVE THE EVENT OF A RANGE TOP GREASE FIRE,
MATERIALS OR VAPORS. OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie
WARNING sheet, or other metal tray, then turn off the gas burner or
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR the electric element. BE CAREFUL TO PREVENT
INJURY TO PERSONS, OBSERVE THE FOLLOWING: BURNS. If the flames do not go out immediately,
A. Use this unit only in the manner intended by the EVACUATE AND CALL THE FIRE DEPARTMENT.
manufacturer. If you have questions, contact the b) NEVER PICK UP A FLAMING PAN - you may be
manufacturer. burned.
B. Before servicing or cleaning the unit, switch power off at c) DO NOT USE WATER, including wet dishcloths or
service panel and lock service panel disconnecting towels - a violent steam explosion will result.
means to prevent power from being switched on d) Use an extinguisher ONLY if:
accidentally. When the service disconnecting means 1) You know you have a class ABC extinguisher,
cannot be locked, securely fasten a prominent warning and you already know how to operate it.
device, such as a tag, to the service panel. 2) The fire is small and contained in the area where
C. Installation Work and Electrical Wiring Must Be Done By it started.
Qualified Person(s) In Accordance With All Applicable 3) The fire department is being called.
Codes & Standards, Including Fire-rated Construction. 4) You can fight the fire with your back to an exit.
D. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (Chimney) of fuel OPERATION
burning equipment to prevent back- drafting. Follow the a. Always leave safety grills and filters in place. Without
heating equipment manufacturers guideline and safety these components, operating blowers could catch onto hair,
standards such as those published by the National Fire fingers and loose clothing.
Protection Association (NFPA), the American Society for
Heating, Refrigeration and Air Conditioning Engineers The manufacturer declines all responsibility in the event of
(ASHRAE), and the local code authorities. failure to observe the instructions given here for installation,
E. When cutting or drilling into wall or ceiling, do not maintenance and suitable use of the product. The
damage electrical wiring and other hidden utilities. manufacturer further declines all responsibility for injury due
F. Ducted systems must always be vented to the outdoors. to negligence and the warranty of the unit automatically
expires due to improper maintenance.
CAUTION
To reduce risk of fire and to properly exhaust air, be
sure to duct air outside - do not vent exhaust air into
spaces within walls, ceilings, attics, crawl spaces, or
garages.

WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCT WORK.

Install this hood in accordance with all requirements


specified.

WARNING
To Reduce The Risk Of Fire Or Electric Shock, Do Not
Use This Hood With Any External Solid State Speed
Control Device.

WARNING
TO REDUCE THE RISK OF A RANGE TOP GREASE
FIRE.
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambeing food (I.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambe).
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate
for the size of the surface element.

3
Electrical & Installation requirements
Electrical requirements Before installing the hood
IMPORTANT 1. For the most efficient air flow exhaust, use a straight run
Observe all governing codes and ordinances. or as few elbows as possible.
CAUTION: Vent unit to outside of building, only.
It is the customers responsibility:
To contact a qualified electrical installer. 2. At least two people are necessary for installation.
To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 3. The hood is fitted with Screws and Drywall Anchors
latest edition*, or CSA Standards C22.1-94, Canadian suitable for most surfaces, consult a Qualified Installer,
Electrical Code, Part 1 and C22.2 No.0-M91 - latest check if they perfectly fit with your cabinet/wall.
edition** and all local codes and ordinances.
4. Do not use flex ducting.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the 5. COLD WEATHER installations should have an additional
ground path is adequate. backdraft damper installed to minimize backward cold air
flow and a nonmetallic thermal break to minimize
Do not ground to a gas pipe. conduction of outside temperatures as part of the
Check with a qualified electrician if you are not sure range ductwork. The damper should be on the cold air side of
hood is properly grounded. the thermal break.
Do not have a fuse in the neutral or ground circuit. The break should be as close as possible to where the
ducting enters the heated portion of the house.
IMPORTANT
Save Installation Instructions for electrical inspectors use. 6. Make up air: Local building codes may require the use of
Make-Up Air Systems when using Ducted Ventilation
The range hood must be connected with copper wire only. Systems greater than specified CFM of air movement.
The specified CFM varies from locale to locale. Consult
The range hood should be connected directly to the fused your HVAC professional for specific requirements in your
disconnect (Or circuit breaker) box through metal electrical area.
conduit.

Wire sizes must conform to the requirements of the National


Electrical Code ANSI/NFPA 70 latest edition*, or CSA
Standards C22.1-94, Canadian Electrical Code Part 1 and
C22.2 No. 0-M91 - latest edition** and all local codes and
ordinances.

A U.L.- or C.S.A.-listed conduit connector must be provided


at each end of the power supply conduit (at the range hood
and at the junction box).

Copies of the standards listed may be obtained from:

* National Fire Protection Association Batterymarch Park Quincy,


Massachusetts 02269

** CSA International 8501 East Pleasant Valley Road Cleveland,


Ohio 44131-5575

4
List of Materials
Parts supplied Parts not supplied
Removing the packaging
CAUTION! Optional Accessories
Remove carton carefully, Wear gloves to protect against Ductless Recirculating Kit
sharp edges. To be used only in the Ductless (Recirculating)
version
WARNING! includes: charcoal filter, charcoal filter support and
Remove the protective film covering the product before fixing bracket, deflector
putting into operation.
Hood structure assembly with blower, transition.
4 Lamps already installed. Tools/Materials required
1 Grease filter Wire nuts
4 Duct covers. Tape to mount template
Hardware bag with: 8" rounded metal duct length to suit installation
Ceiling Mount Template Measuring tape
Use, care and installation guide Pliers
Wood screws (4 pieces - 3/16" x 1" 3/4) Gloves
Glass Brackets, Springs, Gaskets ( 2 each ) Knife
Assembly screws (70 pieces) Safety glasses
4 Plastic Springs Electric drill with 5/16 and 3/8 Bits
Duct cover brackets (4 each) Strain relief
8 Vertical supports. Spirit level
2 Upper Ductcover supports. Duct tape
2 Horizontal supports. Screwdrivers:
Glass canopy Phillips (Posidrive) # 2
Torx # 2
Wire cutter/stripper
Masking tape
Hammer
Saw, jig saw or reciprocating saw

5
Dimensions and Clearances

6
Ducting Options and Examples
Closely follow the instructions set out in this manual.
All responsibility, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this
manual, is declined.

Venting methods
The hood is equipped with a transition B for discharge of fumes to the outside (Ducting version).
Should it not be possible to discharge cooking fumes and vapour to the outside, the hood can be used in the Ductless
(Recirculating) version. Attach a charcoal filter and the deflector F on the duct cover support bracket G. Fumes and vapors
are recycled through the top grille H by means of a duct connected to the transition B and the transition mounted on the
deflector F.
NOTE: For ductless (Recirculating) version only: purchase the Ductless Recirculating Kit.
Minimum Duct Size (Ducting/Ductless version): 8" Round Pipe.

Preparation
Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be
constructed.

Fittings material is provided to secure the hood to most types of walls/ceilings.


However, a qualified technician must verify suitability of the materials in accordance with the type of wall/ceiling.

Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.

Hood installation height above cooktop is the users preference. The lower the hood is above the cooktop, the more efficient the
capturing of cooking odors, grease and smoke.
The hood shall be installed at 24" minimum to 30" above the countertop.
Check your ceiling height and the hood height maximum before you select your hood.

7
Installation
Installation - Ducting version
1. Pre-installation calculations

K = Kitchen Height
C = Counter Height (36" standard)
P = Prefered Height of Hood
Bottom above counter (Recommended 24-30)
H = Hood height your installation
H =K C P
S = Chimney Structure Height, your installation.
S = H - 1" 3/8.

a) Select a hood preference height P that is comfortable for


the user. (from 24 to 30).
b) Calculate Hood height your installation H = K-C-P.
c) Confirm that H is within the range of min to max H found
for your model (See Dimensions and clearances
paragraph). If not adjust your installation.
d) Calculate Chimney structure height S. Save this
calculation for use later in the installation.

Ceiling Support Structures

This vent hood is heavy.


Adequate structure and support must be provided in all
types of installations.
At the hood location, install 2"x 4" cross framing between
ceiling joists as shown. (2"x 4" are required to support
the weight of the hood.)
Arrange cross framing in the ceiling to suit the existing
structure.
Your ceiling joists will be like one of the following
examples.

IMPORTANT
Framing must be capable of supporting 150lbs.

8
Place the template in the ceiling considering the Attach a second vertical support set to adjust the vertical
instructions for ceiling support structures. distance.

Mark with a pencil the hole locations for screws and duct
in the ceiling.

Insert the plastic gaskets on each side of the hood (rear


and front).

Fix the upper horizontal support with 4 wood screws.

Place the Glass Canopy onto the hood.


2 people are recommended to do this.

Attach the vertical supports (inf) (A) to the hood.


Then attach horizontal support (B) (inf).

Place glass brackets using 2 screws by side.

9
Facing the front of the range hood, remove the left knockout
Attach the assembly to the support fixed on the ceiling. and the Junction box cover and install the conduit
Assure with screws (16). connector (cULus listed) in junction box.

Connecting the ductwork


Install ductwork, making connections in the direction of
airflow as illustrated.
Push duct over the exhaust outlet.
Wrap all duct joints and the flange connections with duct
tape for an airtight seal. If not already done, install 1/2 conduit connector in j-
Make the same connection in the wall or ceiling vent box.
exit.

Electrical connection

WARNING
Electrical Shock Hazard
Warning: Turn off power circuit at the service panel
before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.

ELECTRICAL GROUNDING INSTRUCTIONS


THIS APPLIANCE IS FITTED WITH AN ELECTRICAL
JUNCTION BOX WITH 3 WIRES, ONE OF WHICH
Attach the vertical duct cover supports using 4 screws.
(GREEN/YELLOW) SERVES TO GROUND THE
Place each spring using a screw by side.
APPLIANCE. TO PROTECT YOU AGAINST
ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE
MUST BE CONNECTED TO THE GROUNDING WIRE
IN YOUR HOME ELECTRICAL SYSTEM, AND IT
MUST UNDER NO CIRCUMSTANCES BE CUT OR
REMOVED.
Failure to do so can result in death or electrical
shock.

10
Place upper duct covers sliding through until spring Check that the internal General ON/OFF Push button
sounds click. Switch is switched ON.
Then verify.

To get the most efficient use from your new range hood,
Place lower duct covers using one plastic bracket at read the Use and Care Information section.
each vertex (4 needed).
Keep your Installation Instructions and Use and Care
Guide close to range hood for easy reference.

The lower duct cover shall be secured to rangehood by 4


screws.

Install the grease filter and turn power on at service panel.


Check operation of the hood.

If range hood does not operate:

Check that the circuit breaker is not tripped or the house


fuse blown.
Disconnect power supply. Check that wiring is correct.

11
Installation - Ductless (Recirculating) version
1. Pre-installation calculations

K = Kitchen Height
C = Counter Height (36" standard)
P = Prefered Height of Hood
Bottom above counter (Recommended 24-30)
H = Hood height your installation
H =K C P
S = Chimney Structure Height, your installation.
S = H - 1" 3/8.

a) Select a hood preference height P that is comfortable for


the user. (from 24 to 30).
b) Calculate Hood height your installation H = K-C-P.
c) Confirm that H is within the range of min to max H found
for your model (See Dimensions and clearances
paragraph). If not adjust your installation.
d) Calculate Chimney structure height S. Save this
calculation for use later in the installation.

Ceiling Support Structures

This vent hood is heavy.


Adequate structure and support must be provided in all
types of installations.
At the hood location, install 2"x 4" cross framing between
ceiling joists as shown. (2"x 4" are required to support
the weight of the hood.)
Arrange cross framing in the ceiling to suit the existing
structure.
Your ceiling joists will be like one of the following
examples.

IMPORTANT
Framing must be capable of supporting 150lbs.

12
Place the template in the ceiling considering the Attach a second vertical support set to adjust the vertical
instructions for ceiling support structures. distance.

Mark with a pencil the hole locations for screws and duct
in the ceiling.

Insert the plastic gaskets on each side of the hood (rear


and front).

Fix the upper horizontal support with 4 wood screws.

Place the Glass Canopy onto the hood.


2 people are recommended to do this.

Attach the vertical supports (inf) (A) to the hood.


Then attach horizontal support (B) (inf).

Place glass brackets using 2 screws by side.

13
Cut the duct at the measured size.
Attach the assembly to the support fixed on the ceiling. Slip the duct onto the bottom of the deflector.
Assure with screws (16). Place the duct over the exhaust outlet from the hood.
Use duct tape to seal the deflector and at the exhaust
outlet from the hood.

Air deflector installation


Assemble the air deflector with the upper horizontal
support with 2 assembly screws.

Electrical connection

WARNING
Electrical Shock Hazard
Warning: Turn off power circuit at the service panel
before wiring this unit.
Measure from the bottom of the air deflector to the 120 VAC, 15 or 20 Amp circuit required.
bottom of the hood outlet, as shown.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN ELECTRICAL
JUNCTION BOX WITH 3 WIRES, ONE OF WHICH
(GREEN/YELLOW) SERVES TO GROUND THE
APPLIANCE. TO PROTECT YOU AGAINST
ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE
MUST BE CONNECTED TO THE GROUNDING WIRE
IN YOUR HOME ELECTRICAL SYSTEM, AND IT
MUST UNDER NO CIRCUMSTANCES BE CUT OR
REMOVED.
Failure to do so can result in death or electrical
shock.

Facing the front of the range hood, remove the left


knockout and the Junction box cover and install the
conduit connector (cULus listed) in junction box.

14
If not already done, install 1/2 conduit connector in j- Place lower duct covers using one plastic bracket at
box. each vertex (4 needed).

The lower duct cover shall be secured to rangehood by 4


screws.

Attach the vertical duct cover supports using 4 screws.


Place each spring using a screw by side.

Install the grease filter and turn power on at service panel.


Check operation of the hood.

If range hood does not operate:

Check that the circuit breaker is not tripped or the house


fuse blown.
Place upper duct covers sliding through until spring Disconnect power supply. Check that wiring is correct.
sounds click.
Then verify.
Check that the internal General ON/OFF Push button
Switch is switched ON.

To get the most efficient use from your new range hood,
read the Use and Care Information section.

Keep your Installation Instructions and Use and Care


Guide close to range hood for easy reference.

15
Description of the hood & Controls

1. Blower and light controls


2. Lamp housings
3. Grease filter Handle
4. Grease filter
5. Canopy
6. Duct covers
7. Louver holes (Only for Recirculating version)

16
Controls
Use the high suction speed in cases of concentrated kitchen vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes approximately
after terminating cooking.
Note: Hood retains last speed setting when aspiration switch is turned off.

Description of control panel

1. Light Button
Press lamp button to turn ON the light on High Intensity (Lamp state previously OFF).
Press lamp button to turn ON the light on Low Intensity (Lamp state previously ON).
Press lamp button to turn OFF the light (Lamp state previously ON).
2. Timer Button
The default timer setting is 10 minutes, and it can be adjusted between 60 minutes and 1 minute.
After pressing the timer button, the control enters to a timer setup mode, and user can adjust the timer countdown time
with the + and - buttons within 5 seconds. The timer can be initiated immediately pressing the timer button, after
setting the timer duration or pressing the timer button twice (default 10 minutes setting).
If no action occurs within 5 seconds, the countdown will start.
During the timer setup the + and - buttons are dedicated to the timer and no motor action will occur.
Once the timer is initiated, it can be cancelled by pressing the timer button again.
3. Display
Shows the hood settings.
4. - Button. Speed Decrease / OFF
This button is used to decrease the fan speed, or turn OFF the fan.
The fan will turn OFF if the - button is pressed and the hood was in the first speed.
If the fan is at second speed and the - button is pressed, the fan will be set to first speed.
If the fan is at third speed and the - key is pressed, the fan will be set to second speed.
If the fan is at fourth speed and the - button is pressed, the fan will be set to third speed.
If the fan is OFF and the - button is pressed, the control backlight will light up.
5. + Button. Speed Increase / ON
This button is used to increase the fan speed, or turn ON the fan.
The fan will turn ON if the + button is pressed and the hood was OFF.
If the fan is at first speed and the + button is pressed, the fan will be set to second speed.
If the fan is at second speed and the + button is pressed, the fan will be set to third speed.
If the fan is at third speed and the + button is pressed, the fan will be set to fourth speed.
If the fan is at fourth speed and the + button is pressed, a beep will sound.
Clock programming
The clock can be reprogrammed at any time except during an active timed function.
The clock can be displayed in a twelve hour format and valid clock times are from 1:00 to 12:59.
The clock can be reprogrammed pressing the Timer button for 3 seconds, and after, the clock can be adjusted with the +
and - buttons. Colon : will flash indicating clock programming mode.
The user can have minute increments / decrements of 1 minute, but if the user keep pressing the + / - buttons for more
than 1 second, the increments / decrements will be of 5 minutes.
During this option the control will round to the nearest 5 minutes.
The user can finish on reprogramming the clock pressing the Timer button.
After 1 minute of no button pressed the control will accept the programmed clock time and will add one minute to the set
clock.
Grease filter saturation alarm (Optional)
After thirty fan functional hours, the display will show Grease Filter if the fan is active.
When this icon is shown in the display, the grease filters installed are required to be washed.
To reset the grease filter saturation alarm the user must press the + button for 5 seconds, after this action the icon Grease
filter is not displayed, and the hood has the normal display operation.
17
Charcoal filter saturation alarm (Optional)
After one hundred and twenty functional hours of the fan, the display will show Charcoal Filter if the fan is active. When
this icon flashes on display, the charcoal filters installed are required to be replaced or reactivated.
To reset the charcoal filter saturation indication the user must press the - button for 5 seconds, after this time the icon
Charcoal filter is not displayed and the hood has the normal display operation.
Audible signal activation and deactivation
The audible signals can be activated or deactivated pressing the Light button for 5 seconds.
If the audible signal is activated, a tone must sound and the Snd symbol must appear on the display for 3 seconds.
If the audible signal is deactivated, the Snd symbol must appear on the display for 3 seconds and no tone must sound.
Charcoal filter inclusion and exclusion (Recirculating accessories)
The charcoal filter inclusion or exclusion can be set by pressing the + and - buttons at the same time for 5 seconds.
The Inclusion or exclusion of charcoal filter must be selected while the lamps and the motor are OFF.
When the charcoal filter has been excluded, the charcoal filter alarm is disabled.
Heat sensor
The control is equipped with a heat sensor that will turn on the blower at second speed if excessive heat occurs (over 158 F
or 70C) surrounding the control area.
If the blower is OFF or if it is operating at first or second speed, the blower will be set automatically to third speed, the
display shows the word "CArE" to indicate that heat sensor has detected an excessive heat.
During this state, the user may raise the blower speed to fourth speed but can not decrease the speed.
When the temperature level on the hood drops to normal, the blower will operate in the setting defined by the user before the
alarm occured.

18
Maintenance
ATTENTION! Before performing any maintenance operation, isolate the hood from the electrical supply by switching off at the
connector and removing the connector fuse.
Or if the appliance has been connected through a plug and socket, then the plug must be removed from the socket.

Cleaning
The cooker hood should be cleaned regularly (at least with
the same frequency with which you carry out maintenance
of the fat filters) internally and externally. Clean using the
Replacing the light bulb
cloth dampened with neutral liquid detergent. Do not use CAUTION
abrasive products. DO NOT USE ALCOHOL! Before replacing the lamps, switch power off at service
Warning: panel and lock service panel disconnecting means to
Failure to carry out the basic cleaning recommendations of prevent power from being switched on accidentally.
the cooker hood and replacement of the filters may cause
fire risks. NOTE: Turn off the lights and fan. Allow the lights to
Therefore, we recommend oserving these instructions. cool before handling. If new lights do not operate be
The manufacturer declines all responsibility for any damage sure lights are inserted correctly before calling service.
to the motor or any fire damage linked to inappropriate
maintenance or failure to observe the above safety
recommendations.

Grease Filter
Traps cooking grease particles.
This must be cleaned once a month using non aggressive
detergents, either by hand or in the dishwasher, which must
be set to a low temperature and a short cycle. When
washed in a dishwasher, the grease filter may discolour
slightly, but this does not affect its filtering capacity.
To remove the grease filter, pull the spring release handle.

Replace Lights
Remove the inner lamp lens cover by inserting a small
flat blade screwdriver into each of the three slots and
gently prying it free.
NOTE: Do not remove the outer trim ring (lamp
assembly).
Grasp the bulb and pull it straight out.
Replace with 12 volt, 20 watt halogen bulbs with a G4
base SUITABLE FOR USE IN OPEN LUMINAIRES.
Follow package directions, wear gloves, do not
touch bulb with your bare fingers.
Replace inner cover by inserting the three retaining tabs
into the three slots and pressing them firmly in place.

Charcoal Filter
If the model is not vented to the outside, the air will be
recirculated through disposable charcoal filters that help
remove smoke and odors.
The charcoal filters cannot be cleaned.
They must be replaced.
The charcoal filters are clipped inside of each metal grease
filter.
The charcoal filters should be replaced every 4-6 months
(depending on hood usage).
NOTE: DO NOT rinse, or put charcoal filters in an automatic
dishwasher.
NOTE: Charcoal filters are not included with the hood.
They must be ordered from your supplier.
Order the needed kit specifying your hood model and width
size.

19
20

You might also like