RTU5025 GPRS 3G Gate Opener User Manual V1.5

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

GSM Gate, Barrier, Shutter, Garage

Door and Door opener


Open gate or garage door with a FREE
call from your mobile phone!
Remote switching machines with a
FREE call from your mobile phone!

GPRS/3G Gate Opener


Remote Access Control

User Manual
Ver 1.5

RTU5025 Series
Date Issued: 2015-03-25

All rights reserved by


King Pigeon Comm.Co.,Limited.
www.GSM-Gate-Opener.com
A Professional GSM 3G M2M products manufacturer
and automation solution provider, since 2005.
www.GSM-Gate-Opener.com [email protected]

Table of contents
1. Product details --------------------------------------------------------------------------3
1.1 Features------------------------------------------------------------------------------------------------------- 3
1.2 Specifications------------------------------------------------------------------------------------------- 3
1.3 Dimensions---------------------------------------------------------------------------------------------- 3
1.4 Standard Packing List and Model Tabel----------------------------------------------------------------------4
1.5 Applications------------------------------------------------------------------------------------------ 4
2. Safety Directions -----------------------------------------------------------------------4
3. Diagram -----------------------------------------------------------------------------------5
4. Typical Wiring Connection------------------------------------------------------------6
5. Setting by PC software----------------------------------------------------------------7
5.1 Basic Settings-------------------------------------------------------------------------------------------------------7
5.2 Authorized number list managerment------------------------------------------------------------------------8
5.3 Historical data----------------------------------------------------------------------------------------------------------8
6. Setting/Operating by SMS commands --------------------------------------------9
6.1 Change password----------------------------------- -------------------------------------------- 10
6.2 Authorized number managerment---------------------------------------------------------------10
6.3 Relay control parameters--------------------------------------------------------------------------11
6.4 Digital Input parameters----------------------------------------------------------------------------------12
6.5 Self-check auto report/inquiry status/historical data/IMEI code and firmware version-----13
6.6 Data function------------------------------------------------------------------------------------------ 14
7. Important information ----------------------------------------------------------------15
8. Maintenance----------------------------------------------------------------------------15
9. Warranty --------------------------------------------------------------------------------15
10. Authorized users list paper-------------------------------------------------------------16
This handbook has been designed as a guide to the installation and operation of RTU5025 Gate Opener.
Statements contained in the handbook are general guidelines only and in no way are designed to supersede the
instructions contained with other products.
We recommend that the advice of a registered electrician be sought before any Installation work commences.
King Pigeon Communication.Co.,Limited. its employees and distributors, accept no liability for any loss or damage
including consequential damage due to reliance on any material contained in this handbook.
King Pigeon Communication.Co.,Limited. its employees and distributors, accept no liability for GSM Network
upgrading or SIMCard upgrading due to the technology specifications contained in this handbook.

Caution!
Please read this user manual carefully before install/operate the Gate

Opener,basic electronic acknowledges required.


_________________________________________________________________________________________
Page 2 of 16 King Pigeon Communication Co.,Limited. Ver 1.5 File No.:RTU5025103
A Professional GSM 3G M2M products manufacturer
and automation solution provider, since 2005.
www.GSM-Gate-Opener.com [email protected]

1. Product details
The RTU5025 is an upgraded version of famous RTU5015 gate opener, a very simple device which can be used for remote control swing or sliding
gates and doors or switching devices with authorized access management(Caller-ID),well used on door access, gate control, remote switching, or
car parking systems. Actually the RTU5025 can be used in places which require to turn ON/OFF your system, machines, equipments remotely with a
FREE phone call from your mobile or fixed line telephone.
PC software for programming via USB,remote server system over TCP/IP supported*,users can easily download the access historical data anywhere
anytime.

1.1 Features:
Advantages
GSM or 3G band,distribute worldwide applications;
Up to 999 authorized phone numbers can be configured at the specified time for access control;
No call charges.Reject calls from authorized number then carries out the turn ON/OFF action on the first 'ring';
Secure Using Caller-ID for verification, unknown phone calls are ignored;
SMS confirmation of relay actions(door open) to the owner or authorized caller number.
No need remote control or keys for different users;
Up to 1,000 events log,download the operation historical dat by USB or over GPRS;
Multiple applications. (gates, bollards, barriers, garage doors, shutters and access doors or machines);

Digital Inputs
One Digital input for motion sensor or other sensors to protect your door and windows,SMS alert to owner immediately when
triggered;
One Digital input special for secure door and automatically armed when door closed, SMS alert to owner immediately when
door opened illegally.

Setting
SMS command or PC Software programming;
Operate from anywhere anytime, no distance limitation;

1.2 Specifications 1.3 Dimensions


GSM Frequency Quad-band 850/900/1800/1900MHz

900/2100MHz default
3G Band
850/1900MHz optional*

Digita Input 2 NC/NO dry contact

Digital Output 1 Relay, 3A/240VAC

Siren Output 12VDC/1A

DC Power supply 9~24VDC/2A


Power consumption 12V input Max. 50mA/Average 25mA
SIM Card Supporting 3V SIM Card
Antenna 50 SMA Antenna interface
Temperature range -20~+60 C
Humidity range Relative humidity 90%
Backup battery 3.7V/900mAH
Exterior dimension W130mm*D74mm*H27mm
Net Weight 260 g

_________________________________________________________________________________________
Page 3 of 16 King Pigeon Communication Co.,Limited. Ver 1.5 File No.:RTU5025103
A Professional GSM 3G M2M products manufacturer
and automation solution provider, since 2005.
www.GSM-Gate-Opener.com [email protected]

1.4. Standard Packing List


Order Table:
Gate Opener * 1 RTU5025: GSM 850/900/1800/1900MHz
Antenna * 1 RTU5025W: 2G: GSM900/1800MHz,
AC/DC Power adaptor *1, 3G WCDMA : 900/2100MHz UMTS ;
User Manual & PC Software CD x1 RTU5025C: 2G: GSM850/900/1800/1900MHz,
Packing size: 19*14*6 cm 3G: 850/1900MHz UMTS.
Gross Weight: 0.75kg
Optional Accessories:
Door contact sensor,
Motion detector,
Temperature sensor,
Infrared Beam Fence,
Vibration sensor,
Siren. and others.

1.5 Applications:
Remote open/close swing/sliding gates, doors, shutters, garage doors,locks with a free call!
Intrusion security alarm,remote ON/OFF motors, lights, pumps,generators,valves and machines.
Residential: Door,gate,garage access control, electronic fan,microwave,air-conditioner control.
Industry: Remote switch equipment, for example: street lights, solar power, motor, inverter, PLC, pumps, fans, etc.
Agriculture: Remote control pumps, etc.
Business: Remote control electronic boxes,bright billboards,LED signs,etc.

2.Safety Directions
Safe Startup
Do not use Gate Opener when using GSM equipment is prohibited or might bring disturbance or
danger.

Interference
All wireless equipment might interfere network signals of Gate Opener and influence its
performance.

Avoid Use at Gas Station


Do not use Gate Opener at a gas station. Power off Gate Opener when it near fuels or chemicals.

Power it off near Blasting Places


Please follow relevant restrictive regulations. Avoid using the device in blasting places.

Reasonable Use
Please install the product at suitable places as described in the product documentation. Avoid signal
shielded by covering the mainframe.

Use Qualified Maintenance Service


Maintenance can be carried out only by qualified maintainer.

_________________________________________________________________________________________
Page 4 of 16 King Pigeon Communication Co.,Limited. Ver 1.5 File No.:RTU5025103
A Professional GSM 3G M2M products manufacturer
and automation solution provider, since 2005.
www.GSM-Gate-Opener.com [email protected]

3. Diagram

INDICATORS

Power ON: AC/DC power supply is ON.

Alarm Flash quickly: Alarm occurance.

Relay ON: Relay closed(ON).

Flash per 1 second(quickly): registering to cellular network.


II II Flash per 2 seonds: Normal status.
OFF: cant connect to SIM card or unregistered to the cellular network

Connection Terminals

+ Power supply input,Positive wire(Red).


Power
_ Power supply input,Negative wire(Black).

DIN1,Connect to the door locks contact points(if have) or door contact


Digital Door Status
sensor,voltage free(dry contact) ports.
Input
DIN/GND DIN2,Connect to sensor/detectors, voltage free(dry contact) ports.

NO Normally Open port


Relay
COM Common port
Output
NC Normally Close port

+ 12V DC + output,connect to sirens Positive wire.


Siren
_ GND, connect to sirens Negative wire.

USB Connect to PC for configuration and reading the historical data.

ANT Connect to GSM/3G antenna.

_________________________________________________________________________________________
Page 5 of 16 King Pigeon Communication Co.,Limited. Ver 1.5 File No.:RTU5025103
A Professional GSM 3G M2M products manufacturer
and automation solution provider, since 2005.
www.GSM-Gate-Opener.com [email protected]

4. Typical wiring connection:

1. RTU5025 for Gate opener:


Connect the door sensor to DIN1 for door status detection,
and siren for alarm sound,the lock switched ON/OFF by
phone call,power gain from the same AC/DC adaptor.

2. RTU5025 for remote switching pump:


Connect the water level sensor to DIN2 for level detection, and
siren for alarm sound,the pump switched ON/OFF by phone
call. Pumps power gain from the grid/electrocity.
_________________________________________________________________________________________
Page 6 of 16 King Pigeon Communication Co.,Limited. Ver 1.5 File No.:RTU5025103
A Professional GSM 3G M2M products manufacturer
and automation solution provider, since 2005.
www.GSM-Gate-Opener.com [email protected]

5. Setting by PC software instructions (recommend):


1) Open the unit's back side cover and insert the SIM card.
2) Connect the unit's power supply.
3) Send SMS command pwdTELphone number of the RTU5025# to RTU5025 for adjust the time.
for example:1234TEL001911#, this step is MUST.
4) Connect the RTU5025 to computer by USB cable.
5) On compurters desktop,right click "My Computer" >>> "Property" >>>"Hardware" >>"Device Manager".
6) Find "Ports (COM & LPT)",check the port number of "Silicon Labs CP210x USBto UART Bridge",
for example:COM3. (Click here to know how to find out the COM Port on your computer)
7) Run this configurate software,select the COM Port number,for example:COM3.click"Open",the downside
"COM Port" status indicates to Green,connection successful.
8) Click "Log in",default password is 1234. Fill the new password if you had changed before.
9) Click "Read Settings". Configurate the parameters as per you need.
10) Click "Save Settings".
11) After finished the configuration,disconnect the USB cable,restart the unit for enter to working status.

1) Basic settings

Read Settings: Read the basic parameter settings from RTU5025 to PC software.
Save Settings: Save the basic parameter settings to the RTU5025.
Import profile: Import .xls profile, this can use for a number of RTU5025 with similar settings.
Export profile: Export the parameter settings as .xls format to the PC,under the /configuration folder.

_________________________________________________________________________________________
Page 7 of 16 King Pigeon Communication Co.,Limited. Ver 1.5 File No.:RTU5025103
A Professional GSM 3G M2M products manufacturer
and automation solution provider, since 2005.
www.GSM-Gate-Opener.com [email protected]

2) Edit Authorized Number List

Read: Read the authorized number list from RTU5025 to the PC software.
Save: Save the authorized number list to RTU5025.
Import .xls: Import authorized number list (.xls format) profile from PC folder to the software.
Export .xls: Export the authorized number list (.xls format) to the PC,under the /configuration folder.
Export .csv: Export the authorized number list (.csv format) to the PC,under the /configuration folder.
All Always: Select all the numbers as Always can call in to the RTU5025 for access control.
Delete all: Delete all the numbers on the list, after click this button, then click Save button, all the numbers on the RTU5025
will be deleted(Caution to use!).
3) Historical Data

Read data: Read all historical data from RTU5025 to PC software.


Filter: Filter data from the Start-End time.
Export .xls: Export the historical data (.xls format) to the PC,under the /configuration folder.
Export .csv: Export the historical data (.csv format) to the PC,under the /configuration folder.
Deleta all: Click this button will deleta/earse all of the historical data on the RTU5025 (Caution to use!)

_________________________________________________________________________________________
Page 8 of 16 King Pigeon Communication Co.,Limited. Ver 1.5 File No.:RTU5025103
A Professional GSM 3G M2M products manufacturer
and automation solution provider, since 2005.
www.GSM-Gate-Opener.com [email protected]

6. Setting by SMS commands(not recommend,for remote setting only)


Notice:
1. The default Password is 1234.
2. You can program the RTU5025 with SMS commands using your phone. It is safe to do so because in
addition to the fact that other people may not know the number of the SIM inserted in it, we also use a
Password that makes it impossible for others who doesn't know it, to access the system by chance, and
all the action will be recorded.
3. The relay output will change the close or open status by every call in, please note it. Means the first time
call it, it will close the relay to switch on the lock, if the second call in is in the setting time, then the unit
will ignore the setting time, and open the relay, to switch off the lock.
4. Remember that commands must be CAPITAL LETTERS. It is AA not aa, EE not Ee etc. Don't add
spaces or any other character on the SMS commands.
5. The pwd in the command means the password,like 1234 or 5678 if you changed.
6. If the RTU5025 used for gate access only,all you need to do is to change the default password and add
the authorized numbers.
7. If you cannot call to control the RTU5025 or cannot send or receive any SMS message from it.please try
to add + in front of the country code or the phone numbers:

For example:

In China, the country code is 0086The user cell phone number is 13570810254 and has been assigned as
the SMS Alert number, the simcard number in the panel is 13512345678.

Problem 1: Alarm but the user hasnt received the SMS Alert.

Solution: Please plus the country code while you setup the 13570810254 as SMS Alert number, means setup
008613570810254 instead of the 13570810254.

Problem 2: The user number can receive the SMS Alert message from alarm panel, but the alarm panel can
not receive the commands from the user number.

Solution: Please add country code to the simcard number in the alarm panel. Means send sms commands to
008613512345678 instead of 13512345678.

Solution 3: Use mobile phone A to call mobile phone B, the number displayed on B is which you should set
as the dial number; Use mobile phone A send SMS to mobile phone B, the number displayed on B is which
you should set as the SMS alert number; sometimes you may need to use the 00 to replace the + or use the +
to replace the 00 on front of the country code.

8. Export the Authorized number list to .xls/.csv file and keep it for reference in further.
9. Fo security purpose, the RTU5025 will note return any SMS if command error,so please make sure and
check the SMS Commands, or add the country code before the telephone number or check the input is
in ENGLISH INPUT METHOD and CAPS LOCK.
10.The SMS commands that you will certainly use in the RTU5025 are the following:

_________________________________________________________________________________________
Page 9 of 16 King Pigeon Communication Co.,Limited. Ver 1.5 File No.:RTU5025103
A Professional GSM 3G M2M products manufacturer
and automation solution provider, since 2005.
www.GSM-Gate-Opener.com [email protected]

6.0 Start ( this step is MUST):


Send pwdTELphone number of the RTU5025# to the RTU5025 for adjust the time.
E.g.: 1234TEL00861351015# if the SIM card number inside the RTU5025 is 00861351015.
RTU5025 Reply: Set Suces!

6.1 Change Password


1234Pnew password

RTU5025 return: Password changed tonew password, please remember it carefully.if sucessfully.
E.g.: 1234P6666 for change the new password to 6666.

6.2 Authorized number managerment


6.2.0 Add authorized number:

pwdAserial number#authorized number#start time#end time#


A:command code.
serial number: the authorized numbers position,from 001-999.
start time:yy(year)mm(month)dd(day)hh(hour)mm(minute).the start time of this number can call in to control.
end time: yy(year)mm(month)dd(day)hh(hour)mm(minute).the end time of this number can call in to control.
Without start time and end time means: Always can call in to control.
E.g.: 1234A003#123456# to set the phone no.123456 at the 3rd position and always can call in to control.
E.g.: 1234A016#123456#1502050800#1502051000# to set the phone number 123456 at the 16th position,
this number can call in to control during Feb 5th 8:00a.m.(1502050800) to Feb 5th 10:00a.m.(1502051000).

Note: 1. The authorized number means the one who can dial the RTU5025 to control the relay.
2. The Serial Number is the position to store the authorized users, from 001~999.
3. The 1st ~6th position number should be Mobile number because of the alarm message will send to these
6 numbers, and the power failure alarm SMS send to the 1st postion number only.

6.2.1 Inquiry the Authorized numbers position(serial):


pwdAserial number#

E.g.: 1234A002# to check the number on the 2nd position(serial number2).

6.2.2 Inquiry batch users number

pwdALserial number start#serial number end#


!
E.g.: 1234AL002#050# to inquiry the authorized numbers from the 2nd to the 50th,RTU5025 return serval
SMS with the numbers list(10 numbers on each SMS).
6.2.3 Delete the Authorized Number(or you can overwrite this postion with another number).

pwdAserial number##
!
E.g.: 1234A002## to delete the 2nd authorized number.

_________________________________________________________________________________________
Page 10 of 16 King Pigeon Communication Co.,Limited. Ver 1.5 File No.:RTU5025103
A Professional GSM 3G M2M products manufacturer
and automation solution provider, since 2005.
www.GSM-Gate-Opener.com [email protected]

6.3 Relay Control setting


6.3.1 Allow all numbers can call in to control:
pwdALL#

6.3.2 Allow only the authorized numbers can call in to control(Caller-ID for security,default):

pwdAUT#

6.3.3 How long time the relay keep close(ON) after phone call in (unit: second)
pwdGOTclose time#

close time=000~999. Unit:Second


close time=000: relay close 0.5 second then open (use the relay as Latch).
close time=999: relay will always keep close(ON) after call in untill the next call in.
Eg: 1234GOT030# to set relay close 30 seconds(ON) and then open(OFF) after call in.

6.3.4 Who will receive the confirmation SMS when the relay is ON/OFF

pwdGONab#content# for relay ON, pwdGOFFab#content# for relay OFF.


st
ab: the ID code of the 1 number(a) and the caller number(b), =0 means disable, =1 means enable.
content: confirmation SMS content.
ID code RTU5025 send notify SMS to
a b The 1st number Caller number
0 0
0 1
1 0
1 1
Eg: 1234GON11#Door Open#
The 1st number & the caller number receive confirmation SMS when relay is ON(door opened).
Eg: 1234GOFF00#Door Close#
The 1st number & the caller number will not receive confirmation SMS when relay is OFF(door closed)..

6.3.5 No need confirmation SMS when the relay is ON/OFF.


pwdGON## pwdGOFF##

6.3.6 Control the relay ON/OFF by SMS command

pwdCC Return SMS: Relay ON (or the SMS confirmation content which you modified before)

pwdDD Return SMS: Relay OFF(or the SMS confirmation content which you modified before)

The relay close timer according to the before setting 6.3.3: pwdGOTclose time#

_________________________________________________________________________________________
Page 11 of 16 King Pigeon Communication Co.,Limited. Ver 1.5 File No.:RTU5025103
A Professional GSM 3G M2M products manufacturer
and automation solution provider, since 2005.
www.GSM-Gate-Opener.com [email protected]

6.4 Digital Input.


The RTU5025 equips 2 digital inputs.
DIN1 special for secure door and automatically armed when door closed, SMS alert send to the 1st~6th positon
number immediately when door opened illegally.
DIN2 for motion/smoke or other sensors to protect your assets, SMS alert send to the 1st~6th positon number
when there have any alarm occurance.
On alarming situation,after alert SMS send out,RTU5025 will call the 1st number and next number if there have no
answering.

6.4.1 Arm: pwdAA Disarm: pwdBB


! !

6.4.2 Define the DIN1/ DIN2 type.

pwdDIN1NC(NO)# pwdDIN2NC(NO)#
! !
Eg:1234DIN2NO# ,define the DIN2 as NO(Normally Open) type.

6.4.3 Modify the Alert SMS content when inputs alarm(Max. 32 characters).

pwdM1(2)#sms conenton#
#
E.g.: 1234M2#Window open alarm!# Modify the DIN2 alert SMS content to Window open alarm!
DIN1 default alert SMS content: Door opened illegally.
DIN2 default alert SMS content: DIN2 Alarm.

6.4.4 Inquiry the NC/NO type and Alert SMS content of DIN1(2).

pwdMQ#

6.4.5 Digital alarm conditions.


The DIN1/DIN2 will trigger an alarm only under the below two coditions
RTU5025 under the Armed Mode
10mins after the last call in from the authorized numbers. (10mins default,users can modify the time period by
SMS command:

pwdDxxx#
xxx=000~999, unit:minute
!
xxx=000: RTU5025 will always disarm untill arm by SMS command.

_________________________________________________________________________________________
Page 12 of 16 King Pigeon Communication Co.,Limited. Ver 1.5 File No.:RTU5025103
A Professional GSM 3G M2M products manufacturer
and automation solution provider, since 2005.
www.GSM-Gate-Opener.com [email protected]

6.5 Others:
6.5.1 Power failure alarm (unit:minute)

pwdACxxx#

xxx=000~999
xxx=000: power failure alarm SMS to the 1st number once the AC/DC power supply lost.
xxx=999: default, no power failure alarm SMS to be send.

6.5.2 Self-check auto report SMS to the 1st number. (unit:hour)

pwdT#xxx#

xxx=000~999
xxx=000, default,no self-check auto report.
Auto report SMS including:
Arm/Disarm Status;
DIN1/2 status;
Relay status;
GSM signal value(full is 31,cellular signal weak if lower than 14)
AC/DC power supply status.

Inquiry the self-check and auto-report time

pwdT#

6.5.3 Inquiry current status

pwdEE

6.5.4 Inquiry the historical data through SMS

pwdL#yymmdd#yymmdd#

Eg: 1234L#150101#150105# to inquiry the historical data from Janurary 1 to Janurary 5,2015.

6.5.5 Inquiry the GSM modules IMEI code and firmware version

pwdIMEI#

6.5.6 RESET the password


Press and hold the RESET button(closed to the SIM card holder), then power ON,after 6 seconds later, the
RTU5025 will restart,then release the RESET button.
This operation will reset the password to default 1234 only, other parameters reset must be reset by PC software.

6.5.7 Device ID
RTU5025 will create an ID according to the SIM Card number(the last of 8 digits).

_________________________________________________________________________________________
Page 13 of 16 King Pigeon Communication Co.,Limited. Ver 1.5 File No.:RTU5025103
A Professional GSM 3G M2M products manufacturer
and automation solution provider, since 2005.
www.GSM-Gate-Opener.com [email protected]

6.6 Data function: GPRS/UMTS/HSDPA Parameters


RTU5025 can send historical data to remote Central Management System(CMS) server software over mobile
network TCP/IP,users have to build their own remote server system according to the RTU5025 data
protocol.---The CMS software can be server based($500~$800usd) or web based(~12,000usd),due to the high
cost, this function for customer who purchased more than 100pcs RTU5025 only,for small project we suggest
client using PC software to configurate or read historical data via USB cable or SMS.

6.6.1 Enable data function


pwdGPRSON

Disable data function

pwd+GPRSOFF

6.6.2 APN(call your mobile operator to ask the Access Point Name, private APN supported)
pwdG#apn name*user*password#

Eg: 1234Geverywhere*eesecure*secure#
(the example APN name:everywhere, user: eescure, password: secure supported by Orange UK)

6.6.3 CMS Server IP address(or DNS/DDNS) and server port


pwdIPserver IP address or DNS/DDNS name*server port#

Eg: 1234IP175.164.49.20*4006#
When data connection failure or parameters setting wrong,RTU5025 send SMS to the 1st number:
GPRS connect failure.

5.6.5 Data upload to CMS interval time:

pwdGONxxxx#

xxxx=0000~9999, (unit:minute)
xxxx=0000, data function always on,RTU5025 can receive and send data over GRPS/UMTS/HSDPA.
xxxx=9999, default,disable data upload function.

_________________________________________________________________________________________
Page 14 of 16 King Pigeon Communication Co.,Limited. Ver 1.5 File No.:RTU5025103
A Professional GSM 3G M2M products manufacturer
and automation solution provider, since 2005.
www.GSM-Gate-Opener.com [email protected]

7. Important information
1) Please read the User Manual carefully before you install and control the RTU5025.
2) Install the RTU5025 in a hidden place.
3) Avoid getting water into the RTU5025.
4) Have a secure connection to the main power supply.

8. Maintenance
1) In case of failure, please contact the distributor or manufacturer.
2) If the RTU5025 works but fail to send SMS texts, switch the power off and on again after one minute. Test it
after few minutes later,or ensure and check the settings are correct and the cellular signal strong enough.
3) If the RTU5025 works well with sensors but cannot send SMS texts, please change a SIM Card from another
Mobile Operators, and then testing again.
4) Please contact the distributor or manufacturer if the problem cant solved.

9. Warranty
1) The RTU5025 is warranted to be free of defects in material and workmanship for one year from the date of
purchase.
2) This warranty does not extend to any defect, malfunction or failure caused by abuse or misuse by the
Operating Instructions. In no event shall the manufacturer be liable for any alarm system altered by
purchasers.

The End!

Any questions please help to contact us feel free.

_________________________________________________________________________________________
Page 15 of 16 King Pigeon Communication Co.,Limited. Ver 1.5 File No.:RTU5025103
A Professional GSM 3G M2M products manufacturer
and automation solution provider, since 2005.
www.GSM-Gate-Opener.com [email protected]

10. Authorized users list (print this page and fill in for record)
Position User Phone number User Name Always Specific time access

1
2
3
4
5
6

200

_________________________________________________________________________________________
Page 16 of 16 King Pigeon Communication Co.,Limited. Ver 1.5 File No.:RTU5025103

You might also like