0% found this document useful (0 votes)
1K views8 pages

TM2500 Brochure

This document provides details on a GE TM2500 Mobile Duel Fuel/50Hz 22.5MW power generation system consisting of 5 gas turbine generator units on separate trailers. The system can operate on either natural gas or diesel fuel and includes switchgear, controls, and auxiliary systems. Each gas turbine generator unit is contained on its own trailer for transportation. The document outlines electrical and fuel interface requirements as well as dimensions and weights of the individual trailers.

Uploaded by

gustiramadani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views8 pages

TM2500 Brochure

This document provides details on a GE TM2500 Mobile Duel Fuel/50Hz 22.5MW power generation system consisting of 5 gas turbine generator units on separate trailers. The system can operate on either natural gas or diesel fuel and includes switchgear, controls, and auxiliary systems. Each gas turbine generator unit is contained on its own trailer for transportation. The document outlines electrical and fuel interface requirements as well as dimensions and weights of the individual trailers.

Uploaded by

gustiramadani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

GE TM2500 Mobile Duel Fuel/50Hz 22.

5MW Mobil Units

GE TM2500 Scope of Supply Includes:


All TM2500 Trailers and intra-trailer connection
ISO rated at 22.8 Mw @ 50HZ
Mobil 4-trailer System
Step Up Transformer and voltage interconnection, including cabling
300KW 480V auxiliary power for blackstart and aux. Power requirements

Year Manufactured- 2002


Total Hours-500

TM2500 Interface Details

Electrical
Requires 480V, 60Hz, auxiliary power to Motor Control Center main circuit breaker (250 kW)
located in control room/Auxiliary Trailer
Generator output 13.8Kv (60Hz-11.5Kv @ 50Hz)
Switchgear located at rear of main trailer

Fuel
Natural gas fuel must be supplied at 395 (+/-20) PSIG (up to 40 GPM (max) at a rate of 12,000
pph (200 mmbtu/hr or 6 mscf/day)
Must conform to GE specification MD-TM-0000-1 (Natural Gas Fuel for GE Aircraft
Derivative Gas Turbine in Industrial Applications)
Liquid Fuel (Diesel) must be supplied at 30 (+/-10) PSIG, up to 40 GPM (max)
Must conform to GE specification MD-TM-0000-2
Water for Nox Suppression must be supplied at 15PSIG (min) up to 28 GPM (max)
Must conform to GE specification MD-TM-0000-3

Inlet/Exhaust Air
Nominal Inlet air flow 15,000 CFM (120,000 turbine / 30,000 enclosure ventilation)
Exhaust stack height 20 when fully assembled
Flange dimensions 96 x 96
Exhaust gas flow 490,000-550,000 lbs/hr @ 980 degrees F

Foundation
Typically, a solid crushed gravel foundation with 1 steel plates is acceptable
Site must include adequate success and space for maneuvering the trailers, and be relatively
level (<6 per 100) well lit and secure

Controls
Advance control system and Ethernet connections allow for desktop PC control of entire start cycle
and auto-synchronization
Multiple units can be tied to a single HMI all started and brought on line simultaneously
Brush Electric Generator
Air-cooled generator with brushless excitation
Suitable for Class 1, Group D, Div 2 Areas
Minimum changes required for 50Hz conversion
Rated at 32,550 KVA @ 90fp
59 deg. F cooling air
13.8Kv
60Hz (11.5Kv @ 50Hz

Low Emissions with demineralized water injection


25 ppm Nox on gas fuel
42 ppm Nox on diesel fuel

Individual Trailers
Trailer Main Auxiliary Inlet Exhaust
Length 60-0 48-0 48-0 48-0
Width 10-0 8-0 8-0 8-0
Height 13-9 13-6 13-6 13-6
Weight (lbs) 210,000 46,000 46,000 40,000
Contains Gas Turbine, Main Circuit Filters, Cooling Turning Vanes,
Generator, L/o tanks Breaker, Fans, Heating & Silencing,
Woodward Cooling Coils, Vertical
Netcon Control Delta pressure Exhaust Stack
System, MCC, switch and alarm
Transformers,
Back-Up
Batteries

Unit 2 (20MW) TM2500PE 481-694 1,559 Borescope completed 1,174 hrs


Unit 3 (20MW) TM2500PE 481-757 1,632 Borescope completed 1,281 hrs
Unit 4 (20MW) TM2500PE 481-774 1,917 Borescope completed 1,483 hrs
Unit 5 (20MW) TM2500PE 481-364 11,237 Borescope completed 11,236 hrs
Detailed information on the Units is available at the power plant facility.
The units are being sold as an As-Is-Where-Is sale.