Catalogue
Catalogue
Catalogue
C A TA L O G U E
w w w. n e s c o . c o m . a u
NESCO
Electrical Products
TAKE A LOOK AT WHAT WE OFFER
Customer Service
Product Solutions & Systems
Distribution
Australia Wide
Distribution Network
Local Representation
Marketing
Full Colour Product Catalogue
WEB Support
Full Colour PDF Product Sheets
Fax Friendly Documents
Calibration Services
C ontents
www.nesco.com.au
2
TNT Series Options and Accessories
Specifications
Part No. Description
TNT ISOT Isolation Transformer, Fused with handle Catalogue No. TNT ISOT
socket and lead
MARTINDALE MicroPAT+
Features
Rugged design
Test results are stored in the built-in memory and by using the
optional software package test results can be downloaded
to a personal computer
RS-232 interface for barcode input and data output
Performs
Earth continuity test 0 to 19.99
100mA, 10A, 25A test current
Insulation test 0 to 19.9M
500V DC test voltage
Run test 240V mains / AC supply
Earth leakage test 0 -6mA AC
Flash test 0 - 30mA AC
1.5kV A.C. - Class I
3kV A.C. - Class II
Catalogue No. MicroPAT+
Included Accessories
Mains lead 1.7 mtr, earth continuity lead 1.5 mtr c/w heavy
duty crocodile clip, flash test gun, instruction manual,
extension lead adaptor.
Optional Accessories
1021+ Barcode scanner
WinPATS Lite Windows recording software (see page 6) Catalogue No. 1021 SER
4 The following Standards refer only to the inspection and testing method of Clause 2.3 of this Standard,
but not to the intervals of testing in Table 4 above. Refer to the appropriate
AS/NZS 3001Electrical installations Re-locatable premises (including caravans and tents) and their site installations
AS/NZS 3003Electrical installations Patient treatment areas of hospitals and medical and dental practices
and dialysing locations
Specifications
Interval between inspection and tests
Class of equipment Residual Current Devices (RCDs)
Operating Cord
Class I
Class II Push-button time and push - sets and
Type of environment and/or (protectively (double test - by user button test power
equipment earthed) insulated) Portable Fixed Portable Fixed boards
(a) (b) (c) (d) (e) (f) (g) (h)
1 Factories, workshops, places 6 12 Daily, or 6 12 12 6
of work or repair, mths mths before every mths mths mths mths
manufacturing, assembly, use, whichever
maintenance or fabrication is the longer
2 Environment where the 12 12 3 6 12 12 12
equipment or supply flexible mths mths mths mths mths mths mths
cord is subject to flexing in
normal use OR is open to
abuse OR is in a hostile
environment
3 Environment where the 5 yrs 5 yrs 3 6 2 yrs 2 yrs 5 yrs
equipment or supply cord is mths mths
NOT subject to flexing in
normal use and is NOT open
to abuse and is NOT in a
hostile environment
4 Residential type areas of: 2 yrs 2 yrs 6 2 yrs 2 yrs 2 yrs
hotels, residential institutions, mths 6
motels, boarding houses, mths
halls, hostels accommodation
houses, and the like
5 Equipment used for 6 12 3 N/A 12 N/A 12
commercial cleaning mths mths mths mths mths
6 Hire equipment:
Inspection Prior to hire Including N/A N/A Prior to
push-button hire
test by hirer
prior to hire
Test and tag 3 mths N/A 3 mths 12 mths 3mths
7 Repaired, serviced and After repair or service which could affect electrical safety, or on reintroduction
second-hand equipment to service.
If the PDA (Pocket PC) is also fitted with a barcode scanner, the entire
testing process can be virtually completely automated with no operator
data input required.
WinPATS CE E controls the TNT / TNT+ and stores the results obtained
and with the functionality of a PocketPC, all other relevant data can
be entered directly into the application rather than manual notes
Catalogue No. WinPATS CE
having to be used for entry later into a database.
WinPATS lite is the main database which provides the full record
keeping and reporting functions and can be updated either manually,
from WinPATS CE (via a PocketPC with appropriate synchronisation
software) or from any data storage type PAT unit such as the MicroPAT+.
6
AS/NZS 3760
and AS/NZS 3012 which provide guidelines for testing and should be
taken as minimum requirements for this work as these documents are
generally referred to in the relevant legislation in each of the states.
Overview Of Systems
The TNT, TNT+ and the MicroPat+ can be used as stand alone testers
or they can be part of powerful intergrated systems. These are flexible
and scaleable packages utilising modern technologies to provide
efficient and error free data entry and testing. With systems to suit
virtually every business, no matter how large or small.
Micro PAT+
This unit performs insulation and continuity tests along with a run
test, leakage test and finally a flash test. This unit performs class I,
Extension class II tests as well as extension leads and can be downloaded to
Leads a PC. This unit differs from the TNT series in that the results from up
to 1000 tests can be stored in memory for download at a later date.
This is particularly useful if the customer is constantly moving around
a site testing equipment.
FAST
Appliance Passed
PC
TT TM TA
Appliance Test Tags
WinPATS is designed for use with the Micro PAT+ . This allows the
user to capture test results from these units and assign sites, locations
within sites, asset numbers if needed as well as giving the provision
of managing and reporting on individual appliances regarding test
history fault levels and specifications. There is also the provision for
Printer reporting and certificate issue through this software.
7
www.nesco.com.au
TNT
The TNT is capable of testing insulation, earth bond and displaying the
actual test result. Polarity and mains supply connections are indicated
Portable by l.e.d.s. This unit is capable of testing class I, class II, appliances and
Appliances
also comes with an adaptor for extension leads. The unit gives an
actual test result as well as a pass/fail indication on screen and has
the facility to communicate with a PC.
TNT TNT+
The TNT+ performs the same functions as the TNT but with the added
Extension Leads advantages of being able to test and record RCD trip current and time,
as well as load testing incorporating leakage current, load current,
voltage, power factor and power in watts. As with the TNT this unit
also provides the capability of downloading test results to a PC.
Appliance
Failed
RCDs TNT+
FAST
Appliance
Passed
TT TM TA
Portable Isolation Appliance Test Tags
RCDs Transformer
TNT ISOT Socket Bar Code
Scanner
Communication
Option 1
PDA
WinPATS
Lite
1021 USB
Communication
Option 2
WinPATS
Lite
8
A p p l i a n ce Test Tag s
EELB FAST MP
Electrical Equipment Log Book Faulty appliance safety tag NESCO Marking Pen
100 Pages Pack of 50 suits all NESCO Tags.
Writes on most surfaces.
Catalogue No. EELB
TA/TN-custom
Include company logo, phone and fax numbers, e-mail and web addresses.
Box layout can be changed. Talk with our sales staff for other options.
Catalogue No. TA/TN-custom
TM-custom
Include company logo, phone and fax numbers, e-mail and web addresses.
Box layout can be changed. Sequential inspection numbers can be requested.
Talk with our sales staff for other options.
Catalogue No. TM-custom
TT/TTN-custom
Include company logo, phone and fax numbers, e-mail and web addresses.
Box layout can be changed up to three colour printing available.
Sequential inspection numbers can be requested. Talk with our sales
staff for other options.
TA/TN-series
The leading test tag for industrial and construction areas. This is an industrial
quality tag complete with marking pen and security clips. OWNER
COMPLETE WHERE APPLICABLE
NEXT TEST DUE
/ /
CAUTION
AUSTRALIAN MADE
c COPYRIGHT ALL RIGHTS RESERVED RED JAN MARCH
GREEN APR JUNE PLANT NUMBER TEST DATE
DURACK PTY. LTD.
REDG. DES. NO. 110703 BLUE JUL SEPT
/ /
NSW ONLY
TA-1 Red Jan-March TN-1 Red Jan/Sep
YELLOW OCT DEC
SIGNATURE LICENCE
COMPLETE WHERE APPLICABLE
OWNER NEXT TEST DUE
PLEASE INFORM YOUR ELECTRICAL SERVICES IF THIS APPLIANCE IS DEFECTIVE IN ANY WAY
/ /
CAUTION
AUSTRALIAN MADE
c COPYRIGHT ALL RIGHTS RESERVED RED JAN MARCH
PLANT NUMBER TEST DATE
CAUTION
AUSTRALIAN MADE
c COPYRIGHT ALL RIGHTS RESERVED RED JAN MARCH
GREEN APR JUNE PLANT NUMBER TEST DATE
DURACK PTY. LTD.
REDG. DES. NO. 110703 BLUE
YELLOW
JUL
OCT
SEPT
DEC
/ /
SIGNATURE LICENCE
CAUTION
AUSTRALIAN MADE
c COPYRIGHT ALL RIGHTS RESERVED RED JAN MARCH
GREEN APR JUNE PLANT NUMBER TEST DATE
DURACK PTY. LTD.
/ /
TA-5 Orange 6 Monthly Jan-June TN-5 White May/Dec
BLUE JUL SEPT
REDG. DES. NO. 110703
YELLOW OCT DEC
SIGNATURE LICENCE
PLEASE INFORM YOUR ELECTRICAL SERVICES IF THIS APPLIANCE IS DEFECTIVE IN ANY WAY
TM-series
OWNER OWNER OWNER OWNER
Heavy Duty tag using the highest quality adhesive. Suitable for use in all L I C N o. L I C N o. L I C N o. L I C N o.
environments. Also available as a barcode tag. TESTING COMPANY TESTING COMPANY TESTING COMPANY TESTING COMPANY
Insp.
No.
ENSURE TEST IS CURRENT
ENSURE TEST IS CURRENT
Insp.
No.
ENSURE TEST IS CURRENT
BEFORE OPERATING BEFORE OPERATING BEFORE OPERATING BEFORE OPERATING
Insp.
No.
Insp.
No.
RED JAN MARCHRED JAN MARCH RED JAN MARCH RED JAN MARCH
GREEN APR JUNE
GREEN APR JUNE GREEN APR JUNE GREEN APR JUNE
/ / / / / / / /
TM-3 Blue July -Sept TM-8 Burgundy 5 Yearly T E S T D AT E
/ /
T E S T D AT E
/ /
T E S T D AT E
/ /
T E S T D AT E
/ /
P L A N T N o. P L A N T N o. P L A N T N o. P L A N T N o.
TT/TTN-series / /
Test Date
/
Next Test Due
/
Supplied in packs of 100 with marking pen. Suitable for indoor and office use. service contact:
Licence No. / /
Plant No.
For
/ /
Next Test Due Test Date
Also available as a barcode tag. 1234567 / / / Plant /
Licence No.N o . No.
Insp.
service contact: For
Test Date Next Test Due
TT-2 Green April-June TTN-2 Blue Feb/Jul NESCO (07) 3274 2466
CAUTION
Ensure test is current
BY DURACK P/L
1234567 No.
For serviceI ncontact:
sp.
Before operating
TT-3 Blue July -Sept TTN-3 Orange Mar/Nov NESCO (07) 3274 2466
CAUTION
BY DURACK P/L 1234567 No.
Insp.
Ensure test is current
Before operating
TT-4 Yellow Oct-Dec TTN-4 Green Apr/Aug NESCO (07) 3274 2466 BY DURACK P/L
CAU TION
Ensure test is current
Before operating
TT-5 Orange 6 Monthly Jan-June TTN-5 White May/Dec NESCO (07) 3274 2466 BY DURACK P/L
10
Test Tag Customisation Sheet
TT-Series
Please re-write clearly any text you require:
Number of
Phone packs required
Mobile (Min 5 packs per colour)
Fax Red ( )
Address Green ( )
Blue ( )
Yellow ( )
Licence No. Orange ( )
Other text White ( )
Black ( )
Burgundy ( )
(Logo to be supplied on business card, letterhead or
suitable electronic file. Photocopies cannot be used.)
TM-Series
Please re-write clearly any text you require:
Number of
Phone packs required
Mobile (Min 5 packs per colour)
Fax Red ( )
Address Green ( )
Blue ( )
Yellow ( )
Licence No. Orange ( )
Other text White ( )
Black ( )
Burgundy ( )
(Logo to be supplied on business card, letterhead or
suitable electronic file. Photocopies cannot be used.)
TM-Series
Please re-write clearly any text you require:
Number of
Phone packs required
Mobile (Min 5 packs per colour)
Fax Red ( )
Address Green ( )
Blue ( )
Yellow ( )
Licence No. Orange ( )
Other text White ( )
Black ( )
Burgundy ( )
(Logo to be supplied on business card, letterhead or
suitable electronic file. Photocopies cannot be used.)
11
www.nesco.com.au
Number of
Phone packs required
Mobile (Min 5 packs per colour)
Fax Red ( )
Address Green ( )
Blue ( )
Yellow ( )
Licence No. Orange ( )
Other text White ( )
Black ( )
Burgundy ( )
(Logo to be supplied on business card, letterhead or
suitable electronic file. Photocopies cannot be used.)
TM-Series
Please re-write clearly any text you require:
Number of
Phone packs required
Mobile (Min 5 packs per colour)
Fax Red ( )
Address Green ( )
Blue ( )
Yellow ( )
Licence No. Orange ( )
Other text White ( )
Black ( )
Burgundy ( )
(Logo to be supplied on business card, letterhead or
suitable electronic file. Photocopies cannot be used.)
TM-Series
Please re-write clearly any text you require:
Number of
Phone packs required
Mobile (Min 5 packs per colour)
Fax Red ( )
Address Green ( )
Blue ( )
Yellow ( )
Licence No. Orange ( )
Other text White ( )
Black ( )
Burgundy ( )
(Logo to be supplied on business card, letterhead or
suitable electronic file. Photocopies cannot be used.)
12
Te s t I n st r u m en t s C alib rati on
Calibration
Calibration of test eqipment is the only means of establishing and proving that measurements obtained using that
equipment are correct. This does not mean that un-calibrated test equipment is inaccurate but without any proof
of an instruments accuracy, there is no way to confirm that readings taken are in fact correct.
The process of having equipment calibrated is primarily to confirm that the equipment concerned is accurate
within the manufacturers specifications and establishes taceability to known standsards by using commensurately
higher spcification equipment to test against, all of which of course has its own calibration to confirm its status.
Traceability is established only with correct certification and effectively compares individual items against national
and international standards.
NESCO is able to offer traceable calibration certificates with virtually all instruments sold, please consult with
our sales department for additional information.
Optional
The ITC8 can also be ordered complete with a NATA traceable
calibration certificate Catalogue No.ITC8CERT
Specifications
Measuring Range Catalogue No. ITC8
0.5,
1
, 2
, 20
, 200
, 1k
, 10k
, 20k
, 100k
, 1M
, 2M
, 10M
Accuracy
MARTINDALE 250/500/1000V
Digital Insulation Tester
Large 4,000 count backlit digital display with analogue bar graph.
Measures insulation resistance, AV/DC voltage, continuity and resistance
of electrical circuits.
Automatic zero adjust removes the resistance of the test leads.
Output test voltage is displayed during testing.
For higher accuracy testing polarisation index and dielectric absorption
ratio functions are provided.
Included Accessories
Batteries, test leads, instruction manual, carry case
Specifications
Function Measuring Range
M 250V
500V
1000V
AC/DC V 600V
Continuity 0.01 40
Catalogue No. IN2103
Specifications
Function Measuring Range Scale
M 1000V 0-400M
500V 0-200M
250V 0-100M
ACV 0-600V -
Resistance 0-3 -
0-500 -
Catalogue No. 1832IN
14
In su lat io n Te sters
Included Accessories
TL-5 test leads, 6 x AA batteries, instruction manual, carry strap.
Specifications
Function Measuring Range Scale
ACV 0-600V -
Resistance 0-50 -
Included Accessories
DFK0075/A test leads, mains power supply lead, internal 12v NiCad Pack,
instruction manual
Specifications
Function Measuring Range Scale
Included Accessories
Accessory bag, test leads c/w 5kV rated hippo clips, rechargeable battery, power cord and user manual.
Model 5060 also includes Data View Lite software and cables for downloading
Specifications
Included Accessories
2 x AAA batteries
Designed to
Specifications Protection Class
IEC 61010-1
Function Measuring Range
600V
Display 10 Leds Category III
Voltage 12 .690V AC/DC
Single pole 100690V AC Catalogue No. 7090
Included Accessories
Holster, wire temp probe, 9V battery
Specifications
Function Measuring Range
Voltage 500V AC/DC
Current 200mA DC
Resistance 2M
Temperature -40C to 1000C
Continuity Buzzer Catalogue No. 7241
Included Accessories
Case holder, instruction manual
Specifications
Function Measuring Range
Voltage 500V AC/DC
Resistance 40M
Capacitance 200F
Frequency 99.99kHz
Continuity Buzzer sounds at less than 60 Catalogue No. PM3
17
www.nesco.com.au
M ultim e te rs Test In st r u m en t s
Included Accessories
TL-21 test leads, carry strap, instruction manual,
2 x AA batteries
cover closed
Specifications
Function Measuring Range
DCV 1000V
ACV 750V
DCA 0.25A
Resistance 200M
Capacitance 10F
Included Accessories
TL-21 test leads, holster, instruction manual
Optional Accessories
Catalogue No.CC1 Electromate carry case
Specifications
Function Measuring Range
ACV 750V
DCV 1000V
Resistance 2M
18
NEW
SANWA DMM with Hard Case Protection
Versatile digital multimeter
Unique clip on hard front protective cover.
Designed to
Included Accessories Protection Class
IEC 61010-1
Instruction manual
600V
Optional Accessories Category III
Specifications
Function Measuring Range
DCV 500V
ACV 600V
Resistance 40M
Capacitance 100F
Frequency 100kHz
Current 400mA AC/DC
Continuity Buzzer sounds 10 - 80
Duty 10 90%
Diode Test Open voltage approx.1.5VDC Catalogue No. CD800A
Included Accessories
Holster, TL-82 test leads, K-type thermocouple, instruction manual
Optional Accessories
Catalogue No.CC1 Electromate carry case
Test Leads, Carry Cases & Accessories (page 37 & 38)
Specifications
Function Measuring Range
Voltage 1000 AC/DCV
Current 10A AC/DC
Resistance 40M
Continuity Buzzer sounds between 5 and Designed to
120 Protection Class
IEC 61010-1
Capacitance 3000F
600V
Frequency 1MHz Category III
M ultim e te rs Test In st r u m en t s
Designed to
Protection Class
SANWA High Standard DMM PC Series IEC 61010-1
600V
Included Accessories Category III
Instruction manual, holster, TL-82 test leads, (PC510 only K-type thermocouple)
Optional Accessories
With (KB-RS2) cable and (PC Link/PC or PC Link Plus) software, measuring
data is transferred to PC through RS232 port for data logging.
(Temperature Measurement)
Designed to
Protection Class
IEC 61010-1
SANWA PC5000 4 Digit TRMS DMM Advanced Features
600V
Category III
Specifications
Function PC500 PC510 PC5000
TRMS -
Max/Min recording -
Voltage AC - -
(AC+DC)
PC-LINK
Sanwa management software
KB-RS2
Downloading cable
Included Accessories
Carrying case, instruction manual, 2 x LR44
Specifications
Function Measuring Range Resolution
A AC 30/300mA 0.01mA AC
30/300A 0.01A AC Catalogue No. 140
Included Accessories
Carrying case, instruction manual, 2 x LR44
Specifications
Function Measuring Range Resolution
A AC 20 A AC 10mA
200A AC 100mA
A DC 20 A DC 10mA
200A DC 100mA Catalogue No. 240
Included Accessories
TL-3A test leads, carrying case, instruction manual, 1 x 9V battery
Specifications
Function Measuring Range
ACA 400/1000A
DCA 400/1000A
ACV 400/600V
DCV 400/600V
2000
Buzzer Sounds less than 100 Catalogue No. 3800CL
21
www.nesco.com.au
Cl a m p M e te r s Test In st r u m en t s
SEW
W 300A AC Analogue Clamp Meter
Low cost clamp meter
Only one scale in the display window at a time to avoid reading errors.
38mm conductor size
Included Accessories
TL-3A test leads, carrying case, instruction manual, 1 x AA battery
Specifications
Function Measuring Range
ACA 6/15/60/150/300A
ACV 300/600V
DCV 75V
2000
Included Accessories
TL-82 test leads soft carry case,
instruction manual, 2 x AAA batteries
Included Accessories
TL-82 test leads (DCM60L only) soft carry case, Catalogue No. DCM60 & DCM60L
instruction manual, 2 x AAA batteries
Specifications
Function DCM400 DCM400AD DCM60 DCM60L
Current
ACA 40/400A 40/400A 20/200/600A 200/600A
Voltage
DCA - 40/400A - -
ACV 400/600V 400/600V - 600V
Frequency
(A) 20-4k 10kHz - - -
(V) 4k/40k/400k/1MHz - - -
Resistance
400 400 - 200
22
SANWA 2000A AC/DC Clamp Meter
55mm conductor size
Included Accessories
TL-82 test leads carry case, instruction manual, 2 x AAA batteries
Specifications
Function Measuring Range
AC/DCA 40/400/2000A
AC/DCV 400m/4/40/400/600V
Frequency 100/1k/10k/100k/1000kHz
Resistance 400/4k/40k/400k/4000k/40M Catalogue No. DCM2000AD
Included Accessories
Instruction manual, carry case, 2 x AAA batteries
Specifications
Function Measuring Range
AC current 0.1mA to 3000A Catalogue No. MCL-1100D
Included Accessories
Blister packaged, TL-3A test leads, 2 x AA batteries
Specifications
Function Measuring Range
Current 200A AC
Voltage 600V AC/DC
Resistance 0.1 to 40M
Capacitance 1pF to 200F
Frequency 0.001Hz to 9.999MHz
Catalogue No.DT2001
23
www.nesco.com.au
Sp e c ia l P urp o s e
Meters & Accessories Test In st r u m en t s
Included Accessories
Instruction manual, TL-EL 3 pin test lead, shoulder belt, 8 x AA batteries
Optional Accessories
TL-30 test leads
Specifications
Function Measuring Range
Fault Test Current 3-500mA
24
SEW Loop Impedance Tester
The complete electrical network can be analysed by scrolling through the results.
Bad contacts, old wiring or bad earth paths are quickly identified.
Included Accessories
User manual, TL-30 and TL-EL 3-pin test lead, shoulder belt, 8 x AA batteries
Specifications
Function Measuring Range
Loop Impedance L-E, L-N 0.03 to 2000
Test currents in each loop 11.76A at 230V
Voltage L-N, L-E 50 to 230V
Earth resistance 0.01 to 2000
Neutral, Line Resistance 0.01 to 2000
PSC Current L-N, L-E 6kA at 230V
Included Accessories
Instruction manual, factory calibration certificate and test leads.
Optional Accessories
HTE-LINK downloading software c/w interface cable.
Catalogue No. HT 2018
Specifications
See RCD & Loop Impedance functions in the HT2019 specification table page 29..
Sp e c ia l P urp o s e
Meters & Accessories Test In st r u m en t s
Included Accessories
Instruction manual
Catalogue No. 4620
Optional Accessories
Earth resistance and earth resistivity test kits - refer Nesco for details.
Included Accessories
Red, Yellow , Green test leads, auxiliary earth spikes,
measurement probe, instruction manual
Included Accessories
Carry case, instruction manual,
calibration certificate, 4 rods, 4 cables
Optional Accessories
EUROLINK 2000 downloading software and interface cable
The instruments will display in real time the values of all fundamental electrical quantities and the trend waveforms
of voltages and currents. Software provided with these units enlarges the potentialities of the instruments.
From simply recording maximum demands of installations and equipment to recording voltage anomalies every
10ms HT ITALIA can accommodate these requirements in their range.
Simple to use, selection of type of measurement is made by rotating a switch and pressing selection keys.
HT2020E
ENERGY TESTER designed to carry out a complete analysis of the power supply.
HT9032
Power Quality Analyser incorporates the same features as the HT2020E combined with powerful tools for
investigating anomalies and disturbance.
GSC57
Total integration of a unique range of functions in one test unit.
Incorporating the features of the HT9032 with advanced Installation Test Functions and with the addition
of accessories Environmental Testing.
Specifications
Function HT2020E HT9032 GSC57
Voltages
Currents
Phase and Total Active Power
Phase and Total Reactive Power
Phase and Total Apparent Power Catalogue No.HT2020E
Phase and Total Power Factor
Frequency
Harmonics (from the 2nd to the 49th
for Voltage and Current)
Analysis of Voltage Anomalies
Harmonic Analysis
Phase Rotation
Leakage Current to Earth
Earth Resistance & Ground Resistivity
Catalogue No.HT9032
Insulation Resistance
Continuity (Test current up to 10A)
RCD Tripping Time & Current
Line & Loop Impedance
Calculation of Prospective Short
Circuit Current
Environmental Testing (with
accessories temperature,
humidity, air speed, luminosity) Catalogue No.GSC57
27
www.nesco.com.au
Sp e c ia l P urp o s e
Meters & Accessories Te st In st r u m en t s
Installation Tester
Installation Testing is the overall term for the complete The HT2019 Combitestt distributed by NESCO Electrical
range of electrical tests which should be carried out Products provides an economical alternative to a range
on all new electrical installations and also on of separate pieces of test equipment providing the
existing installations which have had additions entire gamut of tests in a single, handheld instrument.
or alterations carried out. Low Resistance testing with >200mA test current,
insulation resistance tests (with test voltages from 50V
Most electrical workers are more than familiar with up to 1000V), multi-function RCD Testing, high current
the most common tests routinely carried out such as; Loop Impedance tests, and <15mA Loop Impedance tests
Insulation Testing & Low Resistance (Continuity), ) apart plus Phase Rotation make the HT2019 the answer.
from these there are also several other tests which are
now part of almost every electricians list of must do Not only does the HT2019 provide a complete testing
tests before signing off a job, Fault Loop Impedance, package but all results may be saved to an internal
RCD Test and on 3 Phase installations, Phase Rotation. memory and can then be transferred to a PC with an
optional download pack which includes software to
The adoption of new standards has made the enable fast and professional presentation of test reports
previously little known Fault Loop Impedance test a for customers. This also removes any doubts about the
virtual prerequisite (even though AS3000 does not call final results, which may be raised when using a manual,
this a mandatory test) and RCD Testing is equally as hand written system as the results are directly
important with these devices being commonplace. transferred from the tester to PC.
RCD AC Type
RCD Type A
RS232 Output
Included Accessories
3-pin plug lead, instruction manual, factory ca
and test leads, test probe and carry bag.
Optional Accessories
Catalogue No. HT-Link management softwa
Specifications
Voltage
Frequency Hz
20 199. 0.1
20 199.9 0.1
200 1999 1
Fault Loop Impedance (15mA test current, without RCD tripping) 1 1999 1
Sp e c ia l P urp o s e
Meters & Accessories Te st In st r u m en t s
Included Accessories
Lamps, carry case, instruction manual, fused lead, screw on alligator clip
Specifications
Function Measuring Range
ACV 240/415V
Catalogue No.STL-5
Included Accessories
Carry case, instruction manual, test leads, 1 x 9V battery
(for motor rotation function)
Catalogue No. ST-860
Included Accessories
Carry case, instruction manual, test leads
Catalogue No. ST-855PR
30
TECPEL Digital Lightmeter
Simple one hand operation
Range from 20 to 200,000 Lux
Resolution 0.01Lux
Backlit display
Max/ Data hold function
Included Accessories
Instruction manual, carry case, 4 x AAA batteries Catalogue No. DLM-530
Specifications
Temperature range 20C to 450C (-4F to 842F)
Power supply 9 volt battery
Catalogue No. 6201 Needle Point Catalogue No. 6202 Surface Probe
Sp e c ia l P urp o s e
Meters & Accessories Test In st r u m en t s
Included Accessories
Instruction manual, holster, 2 x TPK-01 bead probes, 1 x 9V battery
Specifications
Power supply 9V battery
Self test function
Indicators
Green LED battery O.K.
Yellow LED 1mW.cmsq
Red LED and audible tone microwave
leakage above safety levels
Included Accessories
Hard carry case, instruction manual, thermometer,
beaker, and detector Catalogue No. TEK500
32
SEW High Voltage Proximity Detector
The tester works by proximity; it senses that radiated field which
surrounds live conductors.
Visual and audible alert
Eight voltage detection settings -
240/2k/3.3k/6k/11k/22k/33k/66k/132k/275kV AC
Complete with sunrise fitting for hot sticks Catalogue No. 270HP
High impact plastic casing
Battery supply 3 x D batteries
Continuous self test function
Low battery indication
Also available Catalogue No. 270HP-SB (tester complete with 1.2 metre safety stick and carry bag)
Sp e c ia l P urp o s e
Meters & Accessories Te st In st r u m en t s
Amplifier probe
Is designed to identify and trace wires within a group
without damaging the insulation.
Catalogue No. 180CB
Tone generator
Provides a tone and also serves as a continuity and polarity tester.
As well as tone a three-coloured LED displays results.
Included Accessories
Instruction manual, alligator clip test leads, RJ11 test plug,
2 x 9V batteries, carry case.
Included Accessories
Soft carry bag, detector, signal generator, instruction manual
Specifications
Detector
LCD display shows signal strength, battery condition, and signal depth
34
C ab le Lo cati on &
Tr ad in g Eq u ipment
Specifications
Transmitter
Receiver
9V battery supply
Catalogue No. FD650
Included Accessories
Transmitter, detector, carry bag, 3 pin test lead, 9V battery supply (for detector).
Specifications
Transmitter
Fuse protected
Detector
Audible chirp
35
www.nesco.com.au
W i r ing Te s ter s Te st In st r u m en t s
Built in tone generator for tracing and locating cables (optional Tone
Receiver Model TRO2 is required for detection).
Included Accessories
Soft carry case, BNC pigtail cable with alligator clips, user manual,
4 x AA batteries.
Catalogue No. CA7024
Optional Accessories
Tone Receiver TRO2
Built in tone generator for tracing and locating cables (optional Tone Receiver
Model TRO2 is required for detection).
Included Accessories
Soft carry case, BCN pigtail cable with alligator clips, user manual,
4 x AA batteries. Catalogue No. CA7026
Optional Accessories
Tone Receiver Tro2
In the event of opens and shorts TDR technology is used to indicate if the
fault is at the near end or the remote end or if it is somewhere in between.
It will then indicate the distance to the fault up to 150m.
Service check function to detect telephone, 10BaseT, 100Mbit+ and token ring.
Cable length can be measured also the unit generates a tone into all
4 pairs under test that can be used for circuit tracing (optional Tone
Receiver Model TRO2 is required for detection).
Optional Accessories
Tone Receiver Tro2
Wire Mapper Pro Remote Ids (#2 to 5)
Wire Mapper Pro Remote Ids (#6 to 9)
Remote Unit
36
Electromate 1000V Fused Test Leads
Suits most multimeters
Short safety tips
500mA, 50kA fuses
Type A
1000V CATIII Catalogue No. 131301
37
www.nesco.com.au
CTWR
ALVEY Circuit Test Wire Reel
Handy test wire reel fitted with a large stud for meter test lead
connection (no cable or clip supplied)
Catalogue No. CTWR
38
Wo r k p l a c e S af et y Pr o d u ct s
Part No Description
MATRUBBER Rubber Safety Floor Matting - Black
1000mm x 1000mm x 6mm thick
650 Volt AC
Tagged and Tested to AS2978-1995
C/W Protective Carry Bag
OHLMAT Overhead Linesmans Matting Yellow
1000mm long x 350mm drop
650 Volt AC
Tested to AS4202-1994
Catalogue No. MATRUBBER
If used, the fire blanket and burns dressing must be replaced with
new items after a rescue has been effected.
Designed for the rescue of workers in live situations. Essential for all
personnel working in potentially dangerous locations. The type of
equipment you cant afford not to have, but hope you never need.
Wo r kp lace Saf et y Pr o d u ct s
Part No Description
RWKIT Kit components can be selected to suit specific
applications
40
NESCO Workplace First Aid Kits
Government Workplace Health & Safety Advisory Standard for First
Aid in the Workplace.
Contents of a First Aid Kit where the risk of injury or illness is MODERATE
Wo r kp lace Saf et y Pr o d u ct s
Harnesses
Part No Description
Harnesses
Elite Full Body harness with multiple attachement
points: ie rear buttock strap, extended dorsal,
side and front D-rings. Suitable for linesman,
riggers, tower workers & E.W.P work.
480S General Purpose harness, with adjustable leg and
sholder straps, dorsal D-ring, breathable triangular
back. Standard type harness for poletop work.
Can be worn comfortabley all day.
Pole Straps
136 Webbing pole strap and double action snap
hooks with 15mm opening and 90 degree twist
1.8 meter length.
148 As above complete with length adjustment,
by adjuster hook and toggle. 2.4meter length.
Lanyards
176WSA Two No 35 (15mm gap) hooks, 35mm webbing,
c/w shock absorber 1.8 meter length
176SA Two No 35 (15mm gap) hooks, 12mm rope,
c/w shock absorber 1.8 meter length
Catalogue No. Elite
Kit includes
16 x DANGER 240 VOLTS (74mm x 105mm)
8 x DANGER 415 VOLTS (74mm x 105mm)
2 x DANGER HIGH VOLTAGE (148mm x 105mm)
2 x LIVE WIRES (148mm x 105mm)
1 x SWITCHROOM (104mm x 210mm)
1 x DANGER ELECTRICAL EQUIPMENT
42
NESCO Safety Signs
4 convenient sizes to choose from see table below
Water, chemical & U.V. resistant
Prompt delivery
Size Measurement
A 400mm x 280mm
B 195mm x 280mm
C 195mm x 135mm
D 135mm x 92.5mm
Note: To order quote A, B, C or D after the part number relevant to the sign
Wo r kp lace Saf et y Pr o d u ct s
44
Rotating Electrical Plug Lockouts
Outward/Inward Rotation Allows for Easier Application & Storage
Surrounds the electrical plug; protects against accidental reconnection
Unique, patent-pending rotating design allows for easier installation
in confined space applications
Each size roatates into istself to fit effectively into safety lockout application
Red lockout colour identifies the safety lockout application
Complete with high-visability permanent safety labels
Tough, lightweight, dielectric Xenoy thermoplastic bodies
withstand chemicals; perform effectively in extreme conditions
[temperature range -50F (-46C) to +350F (117C)]
Pneumatic Lockout
Prevents Access to Compressed Air
Isolates equipment from compressed air sources
Device is applied to the male fitting, and accommodates most 1/4, 3/8 and
1/2 fittings
Wo r kp lace Saf et y Pr o d u ct s
Lock Outs
Part No Description
Safety Lockout HASP
Lockout Padlocks
47
www.nesco.com.au
Wo r kp lace Saf et y Pr o d u ct s
477 Heavy Steel Ball Valve Lockout Device 1-1/4 to 3 Catalogue No.476
Catalogue No.477
479 Adaptor Arm for 3-, 4- and 5-way valves 1-1/4 thick x
1-5/8 wide
** When properly applied. Complete the lockout with a Master Lock safety padlock.
48
Circuit Breaker Switch Padlock
Provides the flexibility to effectively lock out breaker switches
Flexible steel cable shackle allows padlock to properly lock all types of
circuit breaker lockout devices
Flexi-cable allows the lock body to be moved out of the way, and panel
door to be closed properly
Fits the tight space constraints within circuit breaker shutoff boxes
Numerous key changes are available to minimize the possibility of
unwanted key duplication
Wo r kp lace Saf et y Pr o d u ct s
Specifications
Composition: Natural rubber specifically formulated to ensure high dielectric properties.
RG17000360-11 17000 Volt Working 20000 Volt tested 360 long insulating glove size 11
General Description
The Nesco and Electromate remote control product ranges are basic
wireless switching systems used to operate almost anything.
Lights, gates, security systems, pumps, in fact any device that can be
switched on or off through an electrical circuit can be switched remotely.
Through walls, across paddocks, over car parks, use it where running a
switch wire is impractical or impossible.
With over one million units sold world wide, these systems are well
proven, economical and reliable.
The most basic system must consist of at least one transmitter and one
receiver. The actual components selected will be determined by the
Pump Control
application. Always consult with a Nesco sales consultant if in doubt with
your selected application.
Application Notes
All distances are quoted as line of sight. Although these units will operate
out of sight of each other, they are more effective and reliable when in
visual contact. Receivers must not be mounted near equipment that emits
radio interference, machinery such as variable frequency controllers, DC
motors and controllers, transformers, magnets etc. When using in an
industrial application, always chose a clean circuit to wire the receiver
into. Do not leave transmitters near equipment containing induction coils
such as stereo speakers as this will de-tune the transmitter.
Never use this type of remote control switching device on life endangering
equipment such as overhead cranes, hoists and conveyor belts. There is Industrial Monitoring & Control
specialist equipment designed for these applications.
Garden Lighting
51
www.nesco.com.au
Remote Control A u t o m at io n Pr o d u ct s
NESCO FM Series
First generation remote equipment. Operates on 27MHz with a 12 way
digital decoding footprint. Coding system is user-operated dipswitches on
both the transmitter and receiver. To enable a transmitter to talk to a
receiver the dipswitches in the transmitter must be in identical positions
to the dip switches on the receiver. At least one third of the dipswitches
should be in the on position.
A 27MHz antenna is generally required for successful switching, however FMT PET
in ideal conditions or over short distances a piece of building wire 500mm
long may be sufficient. Maximum transmission time of all fixed
transmitters is 5 minutes.
Transmitters
FMT 302
Specifications
Part Number Description
Receivers
Specifications
Part Number Description
52
NESCO Gigalink Series
The Gigalink is the second-generation remote control, offering more
power, smaller units and increased options. Although the increase in
power will not increase the operating distance, it will make the system
more reliable in poor reception areas. The transmitters are physically
smaller and designed for easy use. The receivers offer more user
programmable options.
GLT-2704
Specifications
Part Number Description
GLT-2701 Single channel
GLT-2708
GLT-2702 Two channel
GLT-2704 Four channel
GLT-2708 Eight channel
GLT-2712E Single channel
12V DC power required
Switching device and antenna required
3km operating distance
GLT-2712E
Receivers
Specifications
Part Number Description
GLR 2701 1028 Volt AC/DC power required
Single channel, *5amp 240-volt relay output non continuous
Programmable output modes
GLR 2702 10-28 Volt AC/DC power required
Two channels, *5 amp 240-volt relay output non continuous
Programmable output modes
GLR 2704 12 or 24 Volt AC/DC power supply required
4 channels, *5 amp 240volt relay output non continuous
Programmable output modes
GLR 240 240-Volt AC power supply required
One channel, 10-amp 240-volt relay output
Programmable output modes
GLR 2708R 12 or 24 Volt AC/DC power required
8 channel, *5 amp 240 volt relay output non continuous
All Gigalink receivers supplied as cards only
Remote Control A u t o m at io n Pr o d u ct s
The GLR 2702 and GLR 2704 have two dipswitches allowing the user
to select momentary, latching or flip flop modes for all channels.
Accessories
Catalogue No. C160
Specifications
Part Number Description Catalogue No. QM150
Antenna
Specifications
Part Number Description
ANT 27S 30cm Long, supplied with mounting socket, requires
a ground plane.
ANT 27M 1.2m Long, supplied with 2m of coax and a universal
mounting base. Does not require a ground plane
ANT 27L 2m Long, marine grade antenna supplied with 2m of
coax and universal mounting base. Does not require
a ground plane
Mounting the antenna for maximum reception is important, follow the
diagrams for recommended mounting positions.
Catalogue No. ANT-27M
Antenna Installation
54
Remote Control Systems
NESCO manufactures and assembles customised REMOTE CONTROL SYSTEMS
for special applications.
Gigalink Kit
This kit contains a GLT2701 transmitter c/w 9V battery and GLR240 receiver
mounted in a C160 IP55 P.V.C. enclosure. It has an operating distance line of site
up to 50 meters without a fixed antenna and up to 150 meters with an antenna.
The kit has been designed for rapid and easy installation and useful for a variety
of applications such as operating pool pumps, outside lighting, warning sirens
and bells. Catalogue No. GLRK-240
240Vac
Antenna
Connection
Block
A
240V
Antenna N
N/C To your
FMR240 control
FMT312E Antenna 10A/240V N/O
PSU1202 circuit
Transmitter
Regulator Shield Switching
12Vdc voltage
C
A N
+ -
Earth
55
www.nesco.com.au
Fl o a t S w itc h e s A u t o m at io n Pr o d u ct s
The AT 920 series is designed for applications like sump pumps, water storage
tanks and clean dams. They do not operate effecively in fluids which are fast
flowing, turbulent, or have large amounts of suspended solids.
56
Timers
Specifications
Name Description
AH3-RA
Features
Multiple time ranges programmable by dip switches
Time ranges from 1 second to 10 minutes
24/240V AC/DC operating voltage
One timed and one user selectable set of contacts
Supplied with Base
Surface mounting kit available [Y40]
Specifications
Name Description
57
www.nesco.com.au
Timers A u t o m at io n Pr o d u ct s
Specifications
Name Description
AH3-RE
Features
Multiple time ranges programmable by dip switches
Time ranges from 3 minutes to 30 hours
24/240V AC/DC operating voltage
One timed and one user selectable set of contacts
Supplied with Base
Surface mounting kit available [Y40]
Specifications
Name Description
58
Off Delay Timer AH5F
Features
True off delay timer
Times out after power is removed
One set of change over contacts
Specifications
Name Description
Rated Voltage 240 Volts AC
Time Range 60 seconds or 30 minutes
Contact 1 change over
Contact rating 5 amps
Reset time 0.3 seconds
Size 48mm X 48mm X 84mm
Catalogue No. AH5F
Base PF085A
Specifications
Name Description
Time range 0-30 seconds
Rated voltage 240 to 415 volts AC
Contact rating 5 Amps resistive
Change over time 0.1 seconds
Reset time 0.3 seconds
Base 8PFA
Size 61mm x 49mm x 70mm Catalogue No. TRD-N
Specifications
Name Description
Rated voltage 240 volts AC
Operating voltage 8 volts AC
Operating resistance 4K
Response time 80 milli-seconds max
Contact rating 5 amps resistive
Base 8PFA
Size 61mm x 49mm x 70mm Catalogue No. AFR-1
59
www.nesco.com.au
Timers A u t o m at io n Pr o d u ct s
ATDV-NC
Features
Asymmetrical cyclic timing
Time ranges from 6 seconds to 60 minutes
110 & 240 Volt AC operation
On & off times independently adjustable
Catalogue No. ATDV-NA
ATDV-NE
Features
Asymmetrical cyclic timing
Time ranges from 3 minutes to 30 hours
110 & 240 Volt AC operation
On & off times independently adjustable
Specifications
Name Description
ATDV
Full time range 1s,10s,1m, 10m
Rated voltage 110/240V AC
Contact rating 5 Amps resistive
Reset time 0.2 seconds
Power consumed 2VA
Mounting base 8PFA
Catalogue No. ATDV-NC
Size 61mm x 49mm x 70mm
ATDV-NC
Full time range 6s, 60s, 6m, 60m
Rated voltage 110/240V AC
Contact rating 5 Amps resistive
Reset time 0.2 seconds
Power consumed 2VA
Mounting base 8PFA
Size 61mm x 49mm x 70mm
ATDV-NE
Full time range 3m, 30m, 3h, 30h
Rated voltage 110/240V AC
Contact rating 5 Amps resistive
Reset time 0.2 seconds
Power consumed 2VA
Mounting base 8PFA Catalogue No. ATDV-NE
Size 61mm x 49mm x 70mm
60
ANLY 3-Phase Sequence Voltage Relay ASM-170-415
Characteristic
Only operational with correct power source voltage and phase sequence.
Suitable for main power source and motor starter circuit to prevent
damage from insufficient phases or phase reversal.
Specifications
Operating Voltage 415V AC
Allowable operating 85~110% of rated operating voltage
voltage range
Rated frequency 50/60 Hz
Contact rating 250VAC 5A resistive load
Reset time 300~600mS
Power Consumption Approx. 2VA
Life Mechanical: 5,000,000 times
Electrical: 100,000 times
Ambient temperature -10 ~ +50C
Ambient humidity Max 85% RH
Catalogue No. ASM-170-415
Base 11 Pin PF113A
Size 80.5 x 35 x 73.3
Specifications
Operating Voltage AC(V) 415
Allowable operating 5% ~ 20% of rated operating voltage
voltage range
Rated frequency 50/60 Hz
Detecting method detect from supply voltage
Reset time AVR 172: 0~10sec adjustable
Contact rating 250VAC 5A (resistive load)
Power consumption Approx. 3VA
Life Mechanical: 5,000,000 times Catalogue No. AVR 172-IIT
Electrical: 100,000 times
Ambient temperature -10 ~ +50C
Ambient humidity Max 85% RH
61
www.nesco.com.au
Timers A u t o m at io n Pr o d u ct s
Specifications
Operating Voltage AC/DC(V): 12~48 or 100~240
Allowable operating 85~110% of rated operating voltage
voltage range
Rated frequency 50/60 Hz
Contact rating 250VAC 5A (resistive load)
Reset time Max 0.1S
Catalogue No. H5CLR
Specifications
Model Sensor Input Control Output Dimensions
AT-501-PR Pt 100 Relay 5A 250VAC 48mm x 48mm
AT-701-PR Pt 100 Relay 5A 250VAC 72mm x 72mm
AT-501-KR K Thermocouple Relay 5A 250VAC 48mm x 48mm
AT-701-KR K Thermocouple Relay 5A 250VAC 72mm x 72mm
Specifications
Name Description
Alarm output 250VAC 5A
Control method PID, PI, P, ON/OFF
Catalogue No. AT-501
Setting Digital setting using front panel keys
Indicator 7 segment display and LED
Operating voltage AC(V): 90~260
Rated frequency 50/60 Hz
Power consumption Approx. 3VA
Measuring accuracy Within 0.3% of present value or 2C
whichever is greater
Proportional band (P) Up to maximum allowable setting by sensor
input type
Integral time (I) 0~1999sec (1 second units)
Derivative time (D) 0~1999sec (1 second units)
Control period 0~65sec (1 second units)
Sampling period 250ms Catalogue No. AT-701
62
To g g le Switches
Mounting Bases
Accessories
Part No. Description
8PFA 8 pin base Din rail or surface mounting hold Catalogue No. 8PFA & PF083A
down clips raised center section
PF083A 8 pin base Din rail or surface mounting raised
center section
PF085A 8 pin base Din rail or surface mounting
recessed center section
P3G-08 8 pin socket reverse pin for surface mounting
Catalogue No. PF085A & P3G-08
recessed center section
APS-3 Probe holder for use wih AFR-1 Holds 3
probes threaded to 6mm
Swi tc he s C o n t r o l Pr o d u ct s
IRS-101-A IRS-201-1A
On-Off, 10 Amp 240V, SPST 3Pin On-Off, 15 Amp 240V, DPST 4Pin
IRS-101-1B IRS-201-2A
On-Off, 10 Amp 240V, SPST 3Pin On-Off, 15 Amp 240V, DPST 4Pin
IRS-101-2B IRS-203-1A
On-Off, 15 Amp 240V, SPST 3Pin On-Off-On, 15 Amp 240V, DPDT 6Pin
IRS-101-3B IRS-2101-2C
On-Off, 15 Amp 240V, SPST 3Pin On-Off, 15 Amp 240V, DPST 4Pin
IRS-101E-1C IRS-101E-1O
On-Off, 15 Amp 240V, SPST 3Pin On-Off, 10 Amp 240V, SPST 3Pin
65
www.nesco.com.au
Swi tc he s C o n t r o l Pr o d u ct s
MRS-101
On-Off, 6 Amp 240V, SPST 2Pin
MWS-01
MRS-201-3 MRS-101-2 MOM(On)-On, 10 Amp 240V,
On-Off, 6 Amp 240V, DPST 4Pin On-Off, 6 Amp 240V, SPST 2Pin SPDT 3Pin
PBS
Specifications
Name Description
Rating AC125V 3A; AC 250V 1A
Contact R; 20M max PBS-11A
On-Off, 1 Amp 240V
Insulation R; DC 500V 100M min
Dielectric Strength AC 1000V, 1 minute
Electrical Life 50,000 cycles
EFH01
Fuse holder 10AMP 240V 6 x 30mm
Specifications
6 x 30mm
20M (max)
DC500V100M
AC2000V/minute
66
VASS Common Plug-In Take Off Boxes
Single Phase
When ordering single phase take off boxes specify phase A, B or C.
Specifications
Rating Order Code
HRC Fuse
20A S1/20/HRC
32A S1/32/HRC
Catalogue No. SI/32/HRC
(HRC Fuse Links available if required)
Cord Clamp S/CC - To grip flexible cables. Fits all Take Off Boxes.
Circuit Breaker
10A S1/10/CB
16A S1/16/CB
20A S1/20/CB
25A S1/25/CB
32A S1/32/CB
Earth Leakage
10A S1/10/ELCB
16A S1/16/ELCB
20A S1/20/ELCB
25A S1/25/ELCB
Catalogue No. SI/20/CB
32A S1/32/ELCB
A C
N B
67
www.nesco.com.au
C o n t r o l Pr o d u ct s
HRC Fuse
20A S4/20/HRC
32A S4/32/HRC
63A S4/63/HRC
100A S4/100/HRC
200A S4/200/HRC
Circuit Breaker
Catalogue No. S4/63/HRC
10A S4/10/CB
16A S4/16/CB
20A S4/20/CB
25A S4/25/CB
32A S4/32/CB
40A S4/40/CB
50A S4/50/CB
63A S4/63/CB
100A S4/100/CB
125A S4/125/CB
160A S4/160/CB
200A S4/200/CB
16A S4/16/ELCB
20A S4/20/ELCB
25A S4/25/ELCB
32A S4/32/ELCB
40A S4/40/ELCB
50A S4/50/ELCB
63A S4/63/ELCB
80A S4/80/ELCB
100A S4/100/ELCB
If the protectors are being installed in the panel where the Neutral to Earth link is, then one protector should be
provided from each phase conductor to neutral (i.e. one protector is required for single phase, and three protectors are
required for three phase). If they are being installed in a panel without the N-E link (e.g. a sub-panel), then an extra
protector should be provided from N-E.
With the exception of the high energy 100kA product, the protectors feature replaceable modules. This allows a failed
protector to be replaced without disturbing the wiring. In addition, the DSD1401SR275 product features alarm contacts.
These provide a changeover contact set, that allows remote monitoring of the protector status.
Specifications
DSD1401SR275 40kA Main Panel, lower lightning area, or unexposed Yes DSD1401SR275M
site, or sub panel in high lightning area
Common specifications
Module Width: 17.5mm
Terminals: up to 35 mm2 (solid), 25 mm2 (stranded)
Maximum Continuous Operating Voltage: 275Vac
DSD1401S275M DSD1101S275M
69
www.nesco.com.au
C o n t r o l Pr o d u ct s
CRITEC
Plug-in Protection
These Power Line Filters are used to provide the final stage of surge protection to electrical and electronic equipment
that connects via an AC power plug. The effectiveness of this simple-to-install protection is assured by virtue of it being
installed close to the equipment to be protected. The product is not the cheapest available, but it does offer excellent
surge ratings combined with series filtering.
The product provides a very solid 20kA surge rating in each of the three modes possible at an outlet (L-N, L-E, and N-E).
The protection in each of these modes uses MOVs in combination with robust thermal disconnects to provide increased
safety of the product.
In addition to the regular shunt protection that is used to divert the surge current to earth, this protector features series
filtering. This filtering further reduces the transient voltage getting through to the equipment, but also slows down the
rate of rise of that voltage, further protecting the equipment.
User convenience is built into this product, with LEDs indicating correct product operation, and mounting flanges
allowing wall mounting if required.
Where the equipment being protected has a telephone connection, it is very important that transient protection is
provided for both the AC power connection and the telephone connection. The PLFA2 RJ11 products provides this
combined protection. The telephone circuitry is approved and complies with ACA requirements. The telephone circuitry
is protected to the same rugged 20kA level as the AC power circuit. As well as a rugged gas arrester, the circuitry
features a solid state thyristor to provide instantaneous clamping of telephone line surges to low values, and
automatically resetting solid state fuses in series with each wire to provide overcurrent protection.
Specifications
AC Protection
Model : PRF A2
Nominal voltage: 240 Vac
Catalogue No. PLF A2
Maximum Continuous Operating Voltage: 275 VAC
Maximum Line Current: 10 A
Surge rating: 20 kA 8/20us in each of L-N, L-E, and N-E modes
Aggregate surge material: 80 kA
Dimensions: 275 mm x 100 mm x 72 mm
Weight: approx. 1.5 kg
Connection: Power cord, 2 m
70
ERITECH SYSTEM 2000
Item Description Rod length Rod Pack U/M Unit Weight
Diameter Size Weight Units
CAR0510 AIR TERMINAL,CU,10x500mm - 711080 500 10 1 EA 0.48 KG
Catalogue No. ATBC Catalogue No. RSC Catalogue No. TTRC Catalogue No. CBR
71
www.nesco.com.au
C o n t r o l Pr o d u ct s
Downconductors Fixings
Item Description Suit Tape Pack U/M Unit Weight
Size Size Weight Units
DCC253 CLIP,TAPE,CU,25X3MM,DCC - 711220 25 x 3 50 EA 0.06 KG
72
Downconductors Fixing Clamps
Item Description Suit Tape Pack U/M Unit Weight
Size Size Weight Units
STC253 CLAMP,TAPE,CU,25X3MM, SQUARE - 711410 25 x 3 5 EA 0.2 KG
C o n t r o l Pr o d u ct s
Notes: LPC122 compliant with AS1768-1991 table 4.4. Suitable for use as a main current carrying conductor, for air
terminations and downconductors.
LPC516 CLAMP,CABLE,SMOOTHWEAVE 1 EA 2 OZ
PARALLEL,BRONZE
Catalogue No. LPC595 Catalogue No. LPC810 Catalogue No. LPC804 Catalogue No. LPC516
74
O v e r h e a d a nd Un d er g r o u n d
Specifications
Part No Description Length Width Depth
75
www.nesco.com.au
O v e r h ead an d Un d er g r o u n d
Specifications
Part No Description Length Width Depth
Accessories
Catalogue No. EMARKER Catalogue No. TMARKER Catalogue No. DANGER SIGN
76
Underground Residential Distribution
The all weather polyethylene construction requires no painting or maintenance, as protection against
corrosion/moisture is not an issue.
The strong but light base and turret allow easy transport and installation. The turret is easily and simply
secured to the base with D head stainless steel screws. The panels are resilient and easily drilled.
Accessories
Part No Description
URDQ1 Complete Short Turret Assembly - includes Turret, Base, Blank Type X panel & 4 D Head bolts
URDQ2 Complete Tall Turret Assembly - includes Turret, Base, Blank type X panel & 4 D Head bolts
URDQ1-3F Complete Short Turret Assembly - includes Turret, Base, 3 Fuse panel fitted with 3 fuse holders
& 1 neutral link & 4 D Head bolts
URDQ2-6F Complete Tall Turret Assembly - includes Turret, Base, 6 Fuse panel fitted with 6 fuse holders
& neutral link & 4 D Head bolts
*For beige add b after above P/N
Turrets
UTSMALL 315 235 300 1.9
UTTALL 550 230 295 2.9
Matching Base
UTBASE 350 550 510 3.6
Accessories
Part No Description
Bolts
DHB10M Stainless Steel D Head bolt M10 x 30mm length
Panels
CTC280 Blank Type X switchboard panel 280 h x 205 w
CTC495 Blank Type X switchboard panel 495 h x 205 w
3F-MPS-AS-SQ 3 fuse panel fitted with 3 x fuse holders & neutral link
6F-MPM-AS-SQ 6 fuse panel fitted with 6 x fuse holders & neutral link
Shrouds
ISP-BK-LG-5mm Termination shroud Black fire retardant PVC
150mm long x 90mm O.D.
ISP-BK-SM-5mm Termination Shroud Black fire retardant PVC Catalogue No. 3F-MPS
90mm long x 66 mm O.D.
D-Head
Bolt Spanners
DSC-M10 D Head Drill Socket attachment
3F-MPS T-handle spanner 780mm length suits all D Head bolts
77
www.nesco.com.au
O v e r h ead an d Un d er g r o u n d
Accessories
Part No Description
FPBNF1V Fibreglass pillar vented
Pillar Dimensions 760H x 450W x 33D
FPBNF1V1D Fibreglass pillar vented single door
Pillar Dimensions 760H x 450W x 33D
FPBNF1V2D Fibreglass pillar vented two door
Pillar Dimensions 760H x 450W x 33D
FPBNF2V1D Fibreglass pillar vented single door
Pillar dimensions 1300H x 450W x 330D
FPBNF2V2D Fibreglass pillar vented two door
Pillar dimensions 1300H x 450W x 330D
GSFPNF1 Type X S/Panel Blank/Frame Assembly (to suit FPBNF1 series)
700H x 410W x 10mm
GSFPNF2 Type X S/Panel Blank/Frame Assembly (to suit FPBNF2 series)
1200H x 410W x 10mm
CBNF1 Lightweight concrete base to suit FPB series
310H x 565W x 335D colour neutral
PSFB2 Security bolts & washers 4 per pillar G304 stainless steel
SLP1 Locking plate to suit padlock 1 per pillar G304 stainless steel
SLB1 Locking bolt for SLP1 1 per pillar G304 stainless steel
Accessories
Part No Description
FPB3CD1D Fibreglass pillar single door
Pillar dimensions 1280H x 710W x 280D
FPB3CD2D Fibreglass pillar two door
Pillar dimensions 1280H x 710W x 280D
GSFP3 Type X S/Panel Blank/Frame Assembly
1100H x 625W x 10mm
CB3 Lightweight concrete base
400H x 960W x 500D colour neutral
PSFB2 Security bolts & washers 4 per pillar G304 stainless steel
78
Earthing Rods & Accessories
Part No Description
Domestic Non-Extendable Earth Rods
BC15 Coupling
Note: The above is a rationalisation of the entire earth rod range. For other
configurations please consult sales office.
79
www.nesco.com.au
O v e r h ead an d Un d er g r o u n d
ECA
Part No Rod Dia. Cable Range Weight (kg)
ECR
ECR5 13 - 15 10 - 50mm2 0.115
ECH
ECH 1914 15 - 19 50 - 120mm2 0.350
Type ECH 1914 takes two cables at right angles to rod. Catalogue No. ECP 1514
Castings are in copper alloy. U-bolt, nuts and spring
washers are stainless steel.
ECX
ECX 1909 13 - 19 16 - 50mm2 0.300
80
Compression Earth Clamps
Made from high conductivity copper. Used where copper earth wire
is looped so as not to cut the earth wire, ensuring continuity of the
Earthing System. Suits a vast range of conductors and earth rods,
12mm to 15mm dia. inclusive.
Specifications
Part No Rod Dia. Cable Size Die
CO/16 12 to 15mm 16 sq mm Profile 6
CO/25 12 to 15mm 25 sq mm
CO/35 12 to 15mm 35 sq mm U-997
CO/50 12 to 15mm 50 sq mm or
CO/70 12 to 15mm 70 sq mm DU1315
CO/95 12 to 15mm 95 sq mm Profile C
CO/120 12 to 15mm 120 sq mm
Specifications
Part No Rod Dia. Cable Size Die
C35/70 12mm 25 sq mm U-O/DUOT
C70/95 12 to 15mm 50 - 70 - 95 U-997/
sq mm DU1315
Earth Rod is compressed with hexagonal die prior to connection of clamp
to avoid radial turning of clamp after earth connection is completed.
Specifications
Part No Cable Run Cable Tap Die Size
E50/70 50 sq mm 50 sq mm
70 sq mm 50 sq mm U-O
70 sq mm 70 sq mm
81
www.nesco.com.au
O v e r h ead an d Un d er g r o u n d
Part No Description
ERB1 Aluminium Alloy casting 76mm high x 120mm wide x
120mm depth features a hinged lid
Part No Description
Earthit 20kg bag Mixture of Bentonite, Gypsum and Sodium Sulphate
Earth Mats
Part No Description
EMAT Galvanised mild steel 1525mm x 915mm
Catalogue No. EMAT
Earth Bond
Part No Description
C70 For Commercial earthing installations - The earthing bond
system provides an earth connection to the steel reinforcement,
offering a virtually indestructible, stable and low resistance
path to earth
Bonding cable - 70mm
3 sec current rating - 10kA
Lug dia - 10mm
Terminal thread - M10
Thread depth - 20mm
Catalogue No. C70
82
Copper Tape
Part No Description
TCEC253050 Tape, copper - 25 x 3mm (50m roll)
Profile 6
Part No Current Rating No of Braids
FCB1-100/300 100 Amps 1
FCB1-200/300 200 Amps 2
FCB1-275/300 275 Amps 3
FCB1-350/300 350 Amps 4
FCB1-425/300 425 Amps 5
FCB1-500/300 500 Amps 6
Note: Standard length is 300mm. Other lengths are available upon request.
FBCB1 prefix denotes a single hole. For 2-hole use prefix FCB2
Catalogue No. FCB1
Part No Description
RCB3-670S 670 amp 315mm in length
83
www.nesco.com.au
O v e r h ead an d Un d er g r o u n d
Step 4 Close the cover and ignite with flint gun. Open the mould
after 10 seconds, when meal has solidified.
84
Closed Tubular Single Eye and Double Eye
These are for light to medium hauling of communication and power cable.
Specifications
Part No Suit cable Max S.W.L. Max
Single & Double O.D. Length in kN Tensile
in mm in mm Load in Kg
Specifications
Part No Suit cable Max S.W.L. Max
O.D. Length in kN Tensile
in mm in mm Load in Kg
O v e r h ead an d Un d er g r o u n d
Swivels
The swivels have been manufactured with sealed bearings and are
precision machined from high-grade steel. They have been NATA
certified for a 3:1 safety factor.
Part No Description
SWI-16 6kN Swivel Clevis to Clevis
A range of fuses from 0.6kN to 62kN are available for the SWI-16 through to SWI-60.
The tolerances on the fuses have been rated at 10%. By removing the high tensile
bolt from the center, and replacing it with the fuse of your choice, you can convert
the swivels into a Breakaway Fused Swivel.
Catalogue No. SWI
Specifications
Part No Height Width Depth Wt-kg
86
Fiberglass Duct/Conduit Rod Tigerod
The fiberglass rod is supplied with detachable pulling eyes. TIGEROD
is detachable and comes in 4mm, 6mm, and 8mm rod. All methods of tracing
conduit from the ground will work with TIGEROD.
All rod has a 1mm sheath of yellow HPDE to render it more noticeable and to
protect the fiberglass from wear. The tigerod dispensing units come with a hand
brake and are strong and durable. The pay-off mechanism on the dispenser has
a double set of rollers to reduce wear on the sheath and rod. The rod is supplied
with the dispenser units. They are short enough to be stored in the back of panel
vans and other small, enclosed vehicles.
The rod comes standard with a 1mm copper tracer wire. Simply energize the rod
with your transmitter and locate your pipe with the aid of a receiver.
O v e r h ead an d Un d er g r o u n d
Features
Fully insulated and waterproof.
Plug in HSCs providing bi-metal connection of service
cables and consumer mains.
Base is suitable for rear entry of consumer mains.
Eliminates UV degradation of PVC consumer mains.
Heavy duty polymide UV stabilised construction.
IP66 rated.
Clear markings.
All connections made with 13mm across flats hexagon headed spanner.
Cover allows for easy exit of bonding tail HSC435/1
Specifications
Part No Description
Features
Flexible joints providing the ultimate barrier to moisture ingression.
Insulation piercing on all positions. No stripping necessary.
Nickel plated interior body.
Ideal for pillar-box or underground pit.
Totally insulated and waterproof. Catalogue No. MUCI SERIES
Use RPS spanner see page 14
TTD Series
Part No No of Connections Cable Range Bolt Head Size AVAILABLE
MUCI2/650 2 6-50mm 13
QUEENSLAND
MUCI3/650 3 6-50mm 13 ONLY
MUCI4/650 4 6-50mm 13
88
SICAME Insulated Line Systems
House Service Connectors
House side connection - Stripped copper consumer mains
Features
Shear heads on both connections.
Fully insulated, waterproof and bi-metallic.
Easily fits into Mains Boxes. Catalogue No. HSC435/1
Optional model available with insulated bonding tail and lug.
Use RPS spanner see page 14
Specifications
Part No Consumer Mains House side only Service Side Tap Copper Earth Tail Bolt Head Size
side mm strip length Range mm
Features
Range of brackets to suit all installations including replacement.
Insulation piercing connections on line and load sides.
Insulated top mounting M8 shear head bolts.
Takes up to 100 amp BS style cartridge (57mm x 22mm).
U.V. Stabilised polymeric body.
Gangable to three phase.
Specifications
Part No Description
AVAILABLE
QUEENSLAND
ONLY
Catalogue No. PF100
89
www.nesco.com.au
O v e r h ead an d Un d er g r o u n d
TTD Series
Mains - Insulated copper or Aluminium Tap - Insulated Copper or Aluminium
Features
Easy and safe to fit on energised cable. Shear heads on all bolts.
No live metal parts are accessible and Tightening bolts are potential free.
there is no need to strip the insulation.
Simultaneous piercing on main and tap. End cap for protection of tap
Completely waterproof. Use RPS spanner see page 14
Withstands 6kV in water.
NTD Series
Mains - Bare Copper or Aluminium Tap - Insulated Copper or Aluminium
TTD Series
Part No Mains Cable mm2 Branch Cable mm2 No of bolts
TTD051FAX 16-95 1.5-10 1
TTD101FAX 6-54 4-35 1
TTD151FAX 25-95 6-35 1
TTD201FAX 35-95 25-95 1
TTD231FAX 25-95 10-50 1
TTD241FAX 50-150 6-35 1
TTD251FAX 50-150 35-95 1
TTD301FAX 35-95 35-95 2
TTD341FAX 50-150 6-35 2
TTD351FAX 50-150 35-95 2
Catalogue No. TTD
TTD401FAX 50-185 50-150 2
TTD431FAX 70-240 16-95 2
TTD451FAX 70-240 50-185 2
NTD Series
Part No Bare Cable Type Bare Conductor mm Insulated Cable
NTD101F Cu 7-54 6-35
NTD151F Cu 35-95 6-35
NTD241F Cu 50-150 6-35
NTD301FA Cu 7-95 35-95
NTD351F Cu 50-150 35-95
NTD401F Cu 50-150 50-150
NTD101AF Alu 7-54 6-35
NTD151AF Alu 35-95 6-35
NTD241AF Alu 50-150 6-35 Catalogue No. NTD
NTD301AF Alu 7-95 35-95
NTD351AFA Alu 50-150 35-95
NTD401AF Alu 50-150 50-150 AVAILABLE
CCW Series
CAW Series
Features
Aluminium cast rollers
Piercing on all tap connectors
Conforms to Australian Standard AS4396
Catalogue No. CAW235 Catalogue No. CAW35
Disconnection of service by easy removal
of the connecctor from the mains
Bi-metallic tap section
Simple M8 socket operation
Two tap (CAW235) available
Use RPS spanner see page 14
Specifications
Part No Mains Range O.D. mm Tap Range Shear
Heads
Suspension Clamps
Features
Suitable for angles up to 30 degrees
Hinged aluminium alloy body with stainless steel fasteners
Reinforced hanging eye to stop wear through vibration
Specifications
Part No Cable Size mm
SC450 50
SC470 95 70 AVAILABLE
SC495 95
QUEENSLAND
ONLY
SC4150 150
91
www.nesco.com.au
O v e r h ead an d Un d er g r o u n d
Simple to install
Simple to install
Aluminium strap
Aluminium strap
AVAILABLE
QUEENSLAND
ONLY
92
Installation Accessories
Part No Description Features
6707BC Running Sheave Sheave can be used for all sizes of mains cable
for LV ABC and including 4 x 95 & 4 x 150mm cable on
bare conductor intermediate, angle or end poles.
Cast aluminium construction.
Can be mounted vertically or can be suspended.
Working Load 1134kg (2500lbs).
Safe and easy to adjust and use.
RPS13/17-6H Ratchet Spanner 13mm across flats and 17mm across flats in one
260mm length spanner.
RPS13/17-6HSH
Ratchet Spanner Reversible ratchet.
200mm length
Suits all sizes of insulation piercing connectors for
cables 1.5mm2 up to 240mm2, most strain clamps
and suspension clamps.
6 point hex (double sided).
Comfortable grip.
Well balanced, lightweight.
93
www.nesco.com.au
O v e r h ead an d Un d er g r o u n d
Specifications
Part No Mains Cable Size mm Die A/F mm
MJPT25CG 25 25 17.3
MJPT35-25CG 35 25 17.3
MJPT35CG 35 35 17.3
MJPT50-25CG 50 25 17.3
MJPT50-35CG 50 35 17.3
MJPT50CG 50 50 17.3
MJPT70-35CG 70 35 17.3
MJPT70-50CG 70 50 17.3
MJPT70CG 70 70 17.3
MJPT95CG 95 95 17.3
MJPT95CG 95 95 21.5
MJPT120CG 120 120 21.5
Catalogue No. MJPT SERIES
MJPT150CG 150 150 21.5
CPTAU16 16 87 14.0
CPTAU25 25 87 14.0
CPTAU35 35 92 17.3
CPTAU50 50 92 17.3
CPTAU70 50 92 17.3
CPTAU95 95 92 17.3
AVAILABLE
QUEENSLAND
ONLY
94
Photo Electric Outdoor Lighting Controls
Built in time delay prevents false cycling caused by lightning flashes
or stray headlights.
Specifications
Housing: UV stabilized high-impact polypropylene
Photocell: I inch cadmium sulfide light sensitive
Turn-On: 1 to 3 foot candles
Turn-on/Turn-off Ratio:
Switch type: Single pole, single throw. Contact position at night normally closed.
Temperature Range: -40degree to 170degree F.
Power consumption: 1.1 watts average at 120 VAC.
Rated life: 5,000 operations minimum at rated load.
Voltage: 208-277
Rating: 1800VA
Specifications
Part No Description
Twisted Conductors
Conductor
Area (sq mm) Construction Core Part No. Standard Pack Colour Code
6 2, 3 & 4 GSG-160-DI-19
10 red
10 2 GSG-160-DI-19
10 2, 3 & 4 GSG-180-DI-19
10 white
16 2 GSG-180-DI-19
95
www.nesco.com.au
O v e r h ead an d Un d er g r o u n d
Part No Description
*Please indicate the colour required by adding the relevant suffix to the
catalogue number.
Standard Colours
W = White
Y = Yellow
R = Red
O = Orange
They are designed to terminate primary, secondary and neutral wire conductors.
AAC/AAAC ACSR Cond. Dia. (mm) Part No. Standard Pack Colour Code
7/1.75 - 5.25 AFG-053 50 purple
96
Fittings for Galvanised Conductors
Rated Holding Strengths: The UTS of the steel fitting approximates that of their equivalent conductors.
1/3.15 3.15 50
GFG--031-CL red
1/3.24 3.24
7/3.25 9.75 20
GFG-100-CL yellow/orange
19/2.00 10.00
Conductor Stranding Conductor O.D. (mm) Part No. Standard Pack Colour Code
3/2.00 4.31 GFS-043 30 yellow
97
www.nesco.com.au
O v e r h ead an d Un d er g r o u n d
98
Fittings for Agricultural Net Support Systems
Steel Line Splice
Specially designed splices give optimum strength while making them easy
to work with, as no special tools are required.
Specifications
Part No Conductor O.D. mm Colour Code Box Quantity
Note:
Dimensions & Performance characteristics in accordance with AS3608, 1989.
Threads in accordance with AS2947.3, 1989.
Dimensions
Part No Voltage Creepage A B C D E Thread Pin Min F.L
P22 22kV 420 168 228 113 R13 R16 Patt C C150/11 11kN
P33 33kV 534 194 279 113 R13 R16 Patt C C/200/11 11kN
Note:
Dimensions and Performance characteristics in accordance with AS2947, 1989.
Thread and Insulator Pin in accordance with AS1154, Part 2, 1985.
O v e r h ead an d Un d er g r o u n d
Note:
Dimensions and Performance characteristics in accordance with AS1137, Part 4 1981 AS3609, 1989.
Note:
Dimensions in accordance with AS2947, 1989.
1515-OH 11 4 315 70
2515-OH 22 6 440 70
3515-OH 33 10 525 70
10 0
Bus-Bar Insulators
Material
Stand off insulators are moulded from, recognised flame resistant fibreglass
reinforced polyester compound. They feature shatter resistance and height
tolerance closer than commonly available in porcelain insulators. Moisture
and heat resistance of insulators is higher than conventional plastic insulators.
Cantilever Strength
One end of the insulator is bolted to a flat plate and a force is applied to the
insert on the other end in a direction parallel to the end at a distance from the SM51
plate equal to the insulators height.
SM76
NOTE: the voltage rating is only meant to be a guide for indoor service. Insulators SM35
mounted within a suitable electrical cabinet are considered indoors even though
the cabinet is outdoors. An insulator will withstand its rated voltage continuously
but industry standards or other specifications may require a different spacing
from conductors of ground for a particular voltage. Wet or dirty conditions may
require derating an insulator.
Styles
Specifications SM35 SM51 SM76
Voltage withstand 10 15 25
Screw (mm) 8 8 10
Weight 55 90 240
Insulator Pins
Shank Stem
Diameter Length Thread Thread
Length Length
Min
Part No Failure A B C J
Load
B100 3.5kN 16 140 50 98 B
101
www.nesco.com.au
O v e r h ead an d Un d er g r o u n d
150 EB16X150
200 EB16X200
250 EB16X250
2000 EB20X2000
Catalogue No. EB
250 EB16250T
350 EB16350T
450 EB16450T
650 EB16650T
250 OEB16X250
450 OEB16X450
Catalogue No. OEB
10 2
Service Hooks / J Hooks JHOOKCE
Specifications
Part No Description
JHOOKTTH M12 x 150 J Hook with thread & 2 nuts & Earth Tag JHOOKT
Hook Bracket
Possible applications
Intermediate, angle or strain poles:
- banded to concrete poles with strainless steel strap
- bolted timber poles
Temporarily attached to concrete or timber pole with strap and ratchet
buckle assembly to support running sheave.
Specifications
Part No Description
IBHB12 Hook Bracket 16mm O.D. 12kN Failing Load Catalogue No. IBHB
IBHB24 Hook Bracket 20mm O.D. 24kN Failing Load
Eye Nuts
Specifications
Part No Description
Crossarm Braces
Specifications
Part No Description
O v e r h ead an d Un d er g r o u n d
Gain Blocks
For mounting crossarms
Specifications
Part No Description
Pole Steps
Specifications
Part No Description
Coachscrews
Specifications
Part No Description
10 4
Shackle Straps
Specifications
Part No Description
O v e r h ead an d Un d er g r o u n d
Scratch Brushes
The use of a suitable scratch brush to remove any existing oxide film, dirt
or grease from the conductor is essential to ensure a sound electrical connection.
Specifications
Part No Description
Width
Part No. Max Conductor Size of Slot Std Pack
Electro Area Area
Natural Brass Tinned mm mm
Conductor Range
Run Tap
Weight
Part No. Stranding Overall Dia. Stranding Overall Dia. Each kg
APC 112 19/3.75 to 61/3.25 18.8 to 29.3 7/3.75 to 37/3.00 11.3 to 21.0 0.936
APC 1122 19/3.75 to 61/3.25 18.8 to 29.3 19.3.75 to 61/3.25 18.8 to 29.3 1.22
Conductors
Part No. Run and Tap Diameter Length mm Weight kg
TOD-7/19
.475
TOD-7/19 SP 7/2.50 to 19.3.75 7mm to 19mm 95
.5
TODSC-7/19
Conductor Range
Run Tap
Weight
Part No. Stranding Overall Dia. Stranding Overall Dia. Fig. Lmm Each kg
AL43 7/1.70 to 7/3.75 5.10 to 11.3 7/1.70 to 7/3.75 5.10 to 11.3 1 35 0.085
ALD58 7/1.75 to 7/4.50 5.25 to 13.5 7/1.75 to 7/4.50 5.25 to 13.5 2 70 0.142
ALD75 7/2.5 to 19/3.75 7.5 to 19.0 7/2.5 to 19/3.75 7.5 to 19.0 3 95 0.330
107
www.nesco.com.au
O v e r h ead an d Un d er g r o u n d
Type CBC-X
A three-piece bonding clamp. the central spacer separates run and tap cables. Provides high contact pressure and
confines the cable strands. Castings are high copper alloy. hardware is stainless steel.
Conductor Range
Run Tap
Weight
Part No. Area mm2 Overall Dia. Area mm2 Overall Dia. Each kg
CBC3 70 to 95 10.70 to 12.60 4 to 95 2.5 to 12.60 0.23
Conductor Range
Weight
Part No. Area mm2 Overall Dia. Length Bolt Size No. of Bolts Each kg
CPG 2595 25 to 95 6.42 to 12.60 60 M10 2 .350
NOTE: The above range is for tap connections. When used for parallel connections the range
is 10mm2 to 95mm2 (4.05 to 12.60mm)
109
www.nesco.com.au
O v e r h ead an d Un d er g r o u n d
Cable Range
Main Tap
Area OD Area OD
Part No. Min Max Min Max Min Max Min Max
RV3 50 95 8.90 12.60 50 95 8.90 12.60
RV4 120 240 14.21 20.25 16 35 5.10 7.65
RV5 120 300 14.21 22.68 35 95 7.65 12.60
RV6 120 240 14.21 20.25 120 240 14.21 20.25
Catalogue No. RV SERIES
RV8 300 800 22.68 37.05 35 150 7.65 15.75
Dimensions
Part No. Fig. B H J W
RV3 1 46 58 10 48
RV4 1 38 58 8 50
RV5 1 45 58 10 48
RV6 2 54 70 10 57
RV8 1 49 77 10 65
11 0
Distribution & Transmission Switchgear Dropout Fuses
Expulsion Type C
Standard Base Units & Accessories
Rated
Rated Rates Arc
Type Breaking Creepage to
Part No Voltage Current Bill kV. Shortening
Designation Capacity Earth mm.
(U) k V. (in) AMP Rod
kA. (sym)
72297/12 XS108 12 100 8/6 125 300 YES
Accessories
Part No Description
69196 Mounting Bracket - Standard Z
69196/3 Mounting Bracket - ZWA
69195 Mounting Bracket - NEMA
69194 Mounting Bracket - Direct to Pole
70584 Earth Support Kit. - Top M10 x 150mm Lg Stainless Steel.
69341/2 Earth support Kit. - Top M10 x 200mm Lg Steel HDG
69894/2 Earth Support Kit. - Bottom M10 x 120mm Lg Steel HDG
70450 Earthing Stirrup Kit. - Bottom
69961 Spark Gap Assembly
72906/12 Fuse Holder - 12/24kV 8/6kA 100A 366mm Lg.
(with ARC Shortening Rod)
72906/24 Fuse Holder - 24/36kV 6/4kA 100A 458mm Lg.
(with ARC Shortening Rod)
70410 Disconnect Blade - 12/24kV 300A 383mm Lg
71846/12 Replacement 12kV Fuse Holder for Older RE Style Dropouts
71846/24 Replacement 24kV Fuse Holder for Older RE Style Dropouts
Disconnector (Isolator)
Rocking Insulator Disconnector
3 Phase Open Airbreak Switch Type PR3
Accessories
Part No Description
69118 PR3 12kV 630 amp with Flicker Arcing Horns
Requires 21636 Crossarm Kit plus Operating Kit
69119 PR3 24kV 630 Amp with Flicker Arcing Horns
Requires 18590 Crossarm Kit plus Operating Kit
69120 PR3 36kV 630 Amp with Flicker Arcing Horns
Requires 24296 Crossarm Kit plus Operating Kit
Catalogue No. PR3
111
www.nesco.com.au
O v e r h ead an d Un d er g r o u n d
Accessories
Part No Description
Part No. Timber Steel Flicker Duogap Top Mtg Pole Voltage Normal BIL kV
Blade Mtg (U) kV
70209/1 12 630A 125
11 2
Fuselinks AK1 Expulsion fuselinks
Certificate of conformance to AS 1033.1 - 1990 Class AK1 @ 12kV & 24kV in
NGK STANGER C type Dropouts. Also suitable for use up to 36kV in single
& Dual Vented Dropout Units.
Specifications
AMPS Type K Speed AMPS Type K Speed
Description & Part No Description & Part No
1 ZXC705-01BK37 20 ZXC705-20BK37
2 ZXC705-02BK37 25 ZXC705-25BK37
3 ZXC705-03BK37 31 ZXC705-31BK37
5&6 ZXC705-06BK37 40 ZXC705-40BK37
8 ZXC705-08BK37 50 ZXC705-50BK37
10 ZXC705-10BK37 63 ZXC705-63BK37
12 ZXC705-12BK37 80 ZXC705-80BK37
16 ZXC705-16BK37 100 ZXC705-100BK37
AMPS Dual Range Surgeproof & Part No
3/10 (C) ZXC705-310BK37
6/20 (F) ZXC705-620BK37
10/30 (J) ZXC705-1030BK37
Note: Flexible Head Adaptors Part No69231/1 (for 1-32 Amp Fuselinks) or 69231/2
(for 40-100 Amp Fuselinks) must be used with older style Top-Latched Dropouts Units.
O v e r h ead an d Un d er g r o u n d
Sectionising
connection and disconnection of network sections
connection of overhead to underground
Single Phase
Part No Description Features
Three Phase
FSD160-3 160 amp Assembled as 3 Phase Gang Operated Disconnector
415V Fuse IPC terminal for 6-95mm2 Al/Cu Cable
Switch Hinged lid accepts DIN (NH) size 00 fuse links AS 2005.21.1 and can be operated
Disconnector using a standard hook stick
Corrosion proof and water resistant
11 4
HSFEKIT House Service Fuse Extractor Kit - The Extractor
Features
For The extraction of House Service Fuses
Also used for disconnecting dropout fuses, isolators & fuse
switch disconnectors.
Can be used to attach the HP-275 proximity tester (page no ??)
The kit consists of 3 x 1.8 metre fibreglass Sticks
1 x 1.2 metre fibreglass sticks with sunrise fitting
1 x fuse extractor head
1 x 4 pocket yellow carry bag
Head section is rated at 100kV per 300mm and complies with IEC 855
Australian made
Catalogue No. HSFEKIT
Hot Sticks can be used for many applications on overhead powerlines and
a wide variety of specialised fittings and tools are available to suit the
sunrise head attachment.
Accessories
Part No Description
P10044 Disconnect hook for attachment to sunrise fitting
Other accessories available upon request
Catalogue No. P10044
Features
The highly visible stripe design of yellow and black is recognisable
as a caution sign.
Its resistant against all types of weather.
Polyethylene ensures complete electric insulation. Catalogue No. TORAEA
Special shape and special-processed joint assure the permanent connection.
Any desired length can be achieved.
Easily coupled together
Accessories
Part No Description
TORAEA Tiger Tail Yellow & Black, 2.5 meter in length
35mm in diameter, Tested to 15kV
115
www.nesco.com.au
O v e r h ead an d Un d er g r o u n d
Ordering Information
Specifications
Part No Extended Length Retracted Length Weight Storage Case
(Nominal Meters) (Nominal Meters) Part No
Accessories
Accessories
Part No Description
5455-10PTU Pig Tail Pole Fuse Extractor Head for use with
telescopic sticks
P10044 Disconnect hook for attachment to sunrise fitting
Catalogue No. P10044
11 6
Barrier Fencing Mesh
Re-usable, high durability barrier fencing Mesh.
Features
Manufactured from polypropylene
UV stabilised Catalogue No. BMO
Bagged for protection/storage
Specifications
Colour Size Weight Part Number
Features
Material - High quality linear low density polyethylene.
Lead free pigments with virgin grade film.
Excellent chemical resistance.
Elongation - Machine direction 350% min - Transverse direction 300% min
Tensile Strength - Machine direction 20N/mm2 - Transverse direction
20N/mm (nominal)
Specifications
Text Colour Size Part Number
Other Texts available include Gas, Irrigation, Sewer, Water, Diesel & Fibre Optic.
NESCO
Electrical Products
Western Australia