TD Optiflux4000 en
TD Optiflux4000 en
The documentation is only complete when used in combination with the relevant
documentation for the signal converter.
1 Product features 3
2 Technical data 8
3 Installation 31
4 Electrical connections 40
5 Notes 43
The OPTIFLUX 4000 has a field proven and unsurpassed lifetime. This is assured by the fully
welded construction, full bore pipe construction, absence of moving parts and wear resistant
liner materials. Even for demanding applications in harsh environments or with aggressive and
abrasive media KROHNEs OPTIFLUX 4000 can offer a solution.
Examples include water injection under high pressures (2500 lbs), sub-sea installations, slurries
with very high solids contents, alkaline solutions and acids, up to chemical dosing, bleaching,
colouring, and black liquor in the paper industry. If required, a solution beyond our standard
scope can be engineered. KROHNE has in-house specialized know-how on constructions,
welding and exotic materials.
For custody transfer applications, OPTIFLUX 4000 has a wide range of certifications including
OIML R49 & R117, MI-001, MI-004 & MI-005.
Highlights
Trusted and accepted flow sensor for all process applications
Proven in use and unsurpassed lifetime
Large installed base more than 300.000 units - in virtually any industry
All welded rugged construction, to extend lifetime of equipment
Good corrosion, erosion / abrasion resistance
Wide choice of materials for housing & flanges including SS, Duplex, 6Mo
Flexibility in sizes including installation lengths, special constructions, special inner
diameters and inner thicknesses
Corrosion resistant and leak tight electrodes. Specials (materials, retractable or pointed) on
demand
External coatings for offshore or subsoil installation. Optional paint specifications acc. to ISO
12944 protective coating
Reliable measurement under very demanding conditions:
including high temperatures up to 180C / 356F, pressures up to 2500 bar, high solids
contents (up to 70%)
Bi-directional flow metering
Wide range of approvals for hazardous areas
Compliant with requirements for custody transfer OIML R49 & R117, MI-001, MI-004 & MI-
005
No grounding rings with virtual reference option on IFC 300
Extensive diagnostic capabilities
Industries
Chemicals
Pulp & Paper
Minerals & Mining
Oil & gas
Iron, Steel & Metals
Water and wastewater
Pharmaceuticals
Applications
For clean liquids
For slurries and pastes with high solids content
For abrasive and aggressive products
1.2 Options
The solution for any industry
Easy installation
Fitting the OPTIFLUX 4000 is easy with the flanged
design and standard ISO insertion lengths. To
further ease the operation, the OPTIFLUX 4000 can
be installed without filters and straighteners. Even
grounding rings are not required with the patented
"Virtual Reference" option on the IFC 300 converter.
IP68
Installation in measurement chambers subject to
(constant) flooding is possible with the IP68 rated
version. The chambers can even be completely
surpassed if the IP68 version is combined with our
special subsoil coating, allowing the OPTIFLUX 4000
to be installed directly in the ground.
Custody transfer
In combination with the IFC 300 converter the
OPTIFLUX 4000 is suitable for custody transfer
applications. It meets the requirements of OIML R49
and can be verified according to Annex MI-001 of the
Measuring Instruments Directive (MID) for cold
water and to OIML R117 and MID Annex MI-005 for
liquids other than water.
Explosion safety
In combination with the IFC 100 or IFC 300 signal
converter, the OPTIFLUX 4000 has received a wide
range of approvals for hazardous areas, including
ATEX, CSA, FM, IEC and NEPSI.
in which:
v = mean flow velocity
k = factor correcting for geometry
B = magnetic field strength
D = inner diameter of flowmeter
The signal voltage U is picked off by electrodes and is proportional to the mean flow velocity v
and thus the flow rate Q. A signal converter is used to amplify the signal voltage, filter it and
convert it into signals for totalizing, recording and output processing.
Measuring system
Measuring principle Faraday's law
Application range Electrically conductive fluids
Measured value
Primary measured value Flow velocity
Secondary measured value Volume flow
Design
Features Fully welded maintenance-free flow sensor.
Flange version with full bore flow tube.
Standard as well as higher pressure ratings.
Broad range of nominal sizes.
Industry specific insertion lengths.
Modular construction The measurement system consists of a flow sensor and a signal converter. It is
available as compact and as separate version.
Compact version With signal converter IFC 050: OPTIFLUX 4050 C
With signal converter IFC 100: OPTIFLUX 4100 C
With signal converter IFC 300: OPTIFLUX 4300 C
Remote version In wall (W) mount version with signal converter IFC 050: OPTIFLUX 4050 W
In wall (W) mount version with signal converter IFC 100: OPTIFLUX 4100 W
In field (F), wall (W) or rack (R) mount version with signal converterIFC 300:
OPTIFLUX 4300 F, W or R
Nominal diameter With signal converter IFC 050: DN2.5... 1200 / 1/10...48"
With signal converter IFC 100: DN2.5...1200 / 1/10...48"
With signal converter IFC 300: DN2.5...3000 / 1/10...120"
Measuring accuracy
Maximum measuring error With IFC 050 signal converter:
Standard: 0.5% of MV 1 mm/s
With signal converter IFC 100:
DN2.5...6: 0.4% of MV + 1 mm/s
DN10...1200: 0.3% of MV + 1 mm/s
With signal converter IFC 300:
DN2.5...6: 0.3% of MV + 2 mm/s
DN10...1600: 0.2% of MV + 1 mm/s
DN1800...3000: 0.3% of MV + 2 mm/s
The additional typical measuring deviation for the current output is 10 A.
The maximum measuring error depends on the installation conditions.
For detailed information refer to Measurement accuracy on page 22.
Repeatability 0.1% of MV, minimum 1 mm/s
Calibration / Verification Standard:
2 point calibration by direct volume comparison.
Optional:
Verification to Measurement Instrument Directive (MID), Annex III (MI-001).
Standard: Verification at Ratio (Q3/Q1) = 80, Q3 2 m/s
Optional: Verification at Ratio (Q3/Q1) > 80 on request
(Only in combination with signal converter IFC 300)
Long term stability 0.1% of MV
Special calibration On request.
MID Annex III (MI-001) EC-Type examination certificate to MID Annex III (MI-001)
(Directive 2004/22/EC)
(Only in combination with signal converter IFC 300)
Diameter range: DN25...1600
Forward and reverse (bi-directional) flow
Liquid temperature range: +0.1C / +50C
For detailed information refer to Legal metrology on page 16.
OIML R49 Certificate of conformity to OIML R49
(Only in combination with signal converter IFC 300)
Diameter range Class 1: DN80...500
Class 2: DN25...50
Forward and reverse (bi-directional) flow
Liquid temperature range: +0.1C / 50C
For detailed information refer to Legal metrology on page 16.
Operating conditions
Temperature
For Ex versions different temperatures are valid. Please check the relevant Ex documentation for details.
Process temperature PTFE / PFA: -40...+180C / -40...+356F for remote versions
PTFE / PFA: -40...+140C /-40...+284F for IFC 300 compact versions
PTFE / PFA: -40...+120C /-40...+248F for IFC 050 and IFC100 compact versions
ETFE: -40...+120C / -40...+248F
Hard rubber: -5...+80C / 23...+176F
PU: -5...+65C / 23...+149F
For more information about temperatures see the temperature table in the manual.
Ambient temperature Standard (with aluminium signal converter housing):
-40+65C / -40+149F
Protect electronics against self-heating with ambient temperatures above +55C /
+131F.
Option (with stainless steel signal converter housing):
-40...+55C / -40+130F
Storage temperature -50+70C / -58+158F
Measuring range -12...+12 m/s / -40...+40 ft/s
Pressure
EN 1092-1 DN2200...3000: PN2.5
DN1200...2000: PN6
DN200...1000: PN10
DN65 and DN100...150: PN16
DN2.5...50 and DN80: PN40
Other pressures on request.
ASME B16.5 1/10...40": 150 lb RF
Other pressures on request.
JIS DN50...1000: 10 K
DN2.5...40: 20 K
Other pressures on request.
ISO insertion length Optional for DN15...600
Vacuum load For detailed information refer to Vacuum load on page 30.
Pressure ranges for secondary For DN25...150:
containment
Pressure resistant up to 40 bar / 580 psi
Burst pressure up to approx. 160 bar / 2320 psi
Pressure loss Negligible
Chemical properties
Physical condition Electrically conductive liquids
Electrical conductivity Water: 20 S/cm
Standard: 1 S/cm
Permissible gas content (volume) IFC 050: 3%
IFC 100: 5%
IFC 300: 5%
Permissible solid content IFC 050: 10%
(volume)
IFC 100: 10%
IFC 300: 70%
Installation conditions
Installation Assure that the flow sensor is always fully filled.
For detailed information refer to Installation on page 31.
Flow direction Forward and reverse.
Arrow on flow sensor indicates positive flow direction.
Inlet run 5 DN
Outlet run 2 DN
Dimensions and weights For detailed information refer to Dimensions and weights on page 24.
Materials
Flow sensor housing DN2.5...15: stainless steel 1.4408
DN20: GTW-S 30
DN25...3000: sheet steel
Other materials on request.
Measuring tube Austenitic stainless steel
Flanges Standard: carbon steel
Other materials on request.
Liner Standard
DN2.5...15: PFA
DN20: PTFE
DN25...150: PFA
DN200...1800: ETFE
Option
DN25...600: PTFE
DN200...1800: PU
DN200...3000: Hard rubber (Ex only)
Other materials on request.
Protective coating On exterior of the meter: flanges, housing, signal converter (compact version) and /
or connection box (field version)
Standard coating
Connection box Only for remote versions
Standard: die-cast aluminium
Option: stainless steel
Measuring electrodes Standard: Hastelloy C
Option: platinum, stainless steel, titanium, tantalum, low noise
Other materials on request.
Grounding rings Standard : stainless steel
Option: Hastelloy C, titanium, tantalum
Grounding rings can be omitted with virtual reference option for the signal
converter IFC 300.
Reference electrode (optional) Standard: Hastelloy C
Option: platinum, stainless steel, titanium, tantalum, low noise
Other materials on request.
Process connections
Flange
EN 1092-1 DN2.5...3000 in PN2.5...40
ASME 1/10...120" in 150...2500 lb RF
JIS DN2.5...1000 in JIS 10...20 K
Design of gasket surface RF
Other sizes or pressure ratings on request.
Electrical connections
For full detail refer to the relevant documentation of the signal converter.
Signal cable (remote versions only)
Type A (DS) In combination with the signal converter IFC 050, IFC 100 and IFC 300
Standard cable, double shielded.
Max. length: 600 m / 1968 ft (dep. on electrical conductivity and flow sensor).
Type B (BTS) Only in combination with the signal converter IFC 300
Optional cable, triple shielded.
Max. length: 600 m / 1968 ft (dep. on electrical conductivity and flow sensor).
I/O For full details of I/O options, including data streams and protocols, see technical
datasheet of the relevant signal converter.
The OPTIFLUX 4300 meets the requirements for water meters of accuracy class 1 and 2.
Q1 = Q3 / R
Q2 = Q1 * 1.6
Q3 = Q1 * R
Q4 = Q3 * 1.25
Figure 2-1: ISO flow rates added to figure as comparison towards OIML
X: Flow rate
Y [%]: Maximum measuring error
1 3% for class 1, 5% for class 2 devices
2 1% for class 1, 2% for class 2 devices
For DN65 to DN1600; same values (DN, R, Q1, Q2, Q3, Q4) as for OIML R49 class 1 are applicable.
The OPTIFLUX 4300 has an EC-type examination certificate and can be verified to the MID Annex
III (MI-001) for water meters with diameter DN25...DN1800. The conformity assessment
procedure followed for OPTIFLUX 4300 is Module B (Type Examination) and Module D (Quality
Assurance of the Production Process).
The maximim permissible error on volumes delivered between Q2 (transitional) flow rate and Q4
(overload) flow rate is 2%.
The maximum permissible error on volumes delivered between Q1 (minimum) flow rate and Q2
(transitional) flow rate is 5%.
Q1 = Q3 / R
Q2 = Q1 * 1.6
Q3 = Q1 * R
Q4 = Q3 * 1.25
Figure 2-2: ISO flow rates added to figure as comparison towards MID
X: Flow rate
Y [%]: Maximum measuring error
2.2.5 MI-005
MI-005
DN Qmax [m3/h] Qmin [m3/h] MMQ[m3] Accuracy
Class
15 5.4 0.27 0.002 0.5
25 20 1.0 0.01 0.3
32 31.3 1.6 0.5 0.3
40 31.3 1.6 0.5 0.3
50 50 2.5 0.5 0.3
65 125 6.3 2 0.3
80 200 10 2 0.3
100 312.5 15.6 2 0.3
125 500 25 5 0.3
150 500 25 5 0.3
200 1250 62.5 10 0.3
250 2000 100 20 0.3
300 3125 156 50 0.3
350 3125 156 50 0.3
400 5000 250 50 0.3
450 5000 250 50 0.3
500 7875 787.5 100 0.3
Reference conditions
Medium: water
Temperature: +5...+35C / +41...+95F
Operating pressure: 0.1...5 barg / 1.5...72.5 psig
Inlet section: 5 DN
Outlet section: 2 DN
Accuracy
Flow sensor diameter Signal converter type Accuracy Curve
1
DN2.5...6 / /10..." IFC 300 0.3% of mv + 2 mm/s 2
Accuracy
Flow sensor diameter Signal converter type Accuracy Curve
DN2.5...6 / 1/ ..." IFC 100 0.4% of mv + 1 mm/s 4
10
All data given in the following tables are based on standard versions of the flow sensor only.
Especially for smaller nominal sizes of the flow sensor, the signal converter can be bigger
than the flow sensor.
Note that for other pressure ratings than mentioned, the dimensions may be different.
For full information on signal converter dimensions see relevant documentation.
EN 1092-1
Nominal size Dimensions [mm] Approx.
weight [kg]
DN PN [bar] L H W
DIN ISO
2.5...6 40 130 - 142 90 3
10 40 130 1 - 106 90 6
15 40 130 1 200 106 95 6
20 40 150 200 158 105 7
25 40 150 200 140 115 4
32 40 150 200 157 140 5
40 40 150 200 166 150 5
50 40 200 200 186 165 9
65 16 200 200 200 185 9
80 40 200 200 209 200 12
100 16 250 250 237 220 15
125 16 250 250 266 250 19
150 16 300 300 300 285 27
200 10 350 350 361 340 34
250 10 400 450 408 395 48
300 10 500 500 458 445 58
350 10 500 550 510 505 78
400 10 600 600 568 565 101
450 10 600 - 618 615 111
500 10 600 - 671 670 130
600 10 600 - 781 780 165
700 10 700 - 898 895 248
800 10 800 - 1012 1015 331
900 10 900 - 1114 1115 430
1000 10 1000 - 1225 1230 507
1200 6 1200 - 1417 1405 555
1400 6 1400 - 1619 1630 765
1600 6 1600 - 1819 1830 1035
1800 6 1800 - 2027 2045 1470
2000 6 2000 - 2259 2265 1860
1 150 mm for construction according to order code VN03 (contact sales).
150 lb flanges
Nominal size Dimensions [inch] Approx. weight
[lb]
ASME PN [psi] L H W
1/10" 284 5.12 5.59 3.50 6
1/8" 284 5.12 5.59 3.50 6
" 284 5.12 5.59 3.50 6
3/8" 284 5.12 1 5.08 3.50 12
" 284 5.12 1 5.08 3.50 12
" 284 5.91 5.28 3.88 18
1" 284 5.91 5.39 4.25 7
1 " 284 5.91 5.98 4.62 7
1 " 284 5.91 6.10 5.00 11
2" 284 7.87 7.05 5.98 18
2 " 284 7.87 7.72 7.00 24
3" 284 7.87 8.03 7.50 26
4" 284 9.84 9.49 9.00 40
5" 284 9.84 10.55 10.0 49
6" 284 11.81 11.69 11.0 64
8" 284 13.78 14.25 13.5 95
10" 284 15.75 16.3 16.0 143
12" 284 19.69 18.78 19.0 207
14" 284 27.56 20.67 21.0 284
16" 284 31.50 22.95 23.5 364
18" 284 31.50 24.72 25.0 410
20" 284 31.50 26.97 27.5 492
24" 284 31.50 31.38 32.0 675
1 5.91" for construction according to order code VN03 (contact sales).
300 lb flanges
Nominal size Dimensions [inch] Approx. weight
[lb]
ASME PN [psi] L H W
1/10" 741 5.12 5.59 3.75 6
1/8" 741 5.12 5.59 3.75 6
" 741 5.12 5.59 3.75 6
3/8" 741 5.12 1 5.24 3.75 15
" 741 5.12 1 5.24 3.75 15
" 741 5.91 5.67 4.62 20
1" 741 5.91 5.71 4.87 11
1 " 741 7.87 6.65 6.13 13
2" 741 9.84 7.32 6.50 22
3" 741 9.84 8.43 8.25 31
4" 741 11.81 10.00 10.0 44
6" 741 12.60 12.44 12.5 73
8" 741 15.75 15.04 15.0 157
10" 741 19.69 17.05 17.5 247
12" 741 23.62 20.00 20.5 375
14" 741 27.56 21.65 23.0 474
16" 741 31.50 23.98 25.5 639
20" 741 31.50 28.46 30.5 937
24" 741 31.50 33.39 36.0 1345
1 5.91" for construction according to order code VN03 (contact sales).
Please note that the specified values only refer to the flanges. The maximum value for the
flowmeter can further be limited by the maximum value for other materials (i.e. the liner)
[mm] [bar] 40C 60C 70C 80C 90C 100C 120C 140C 180C
Liner in PTFE
DN10...20 50 0 0 0 0 0 0 500 750 1000
DN200...300 50 500 750 1000 1000 1000 1000 1000 1000 1000
DN350...600 50 800 1000 1000 1000 1000 1000 1000 1000 1000
Liner in PFA
DN2.5...150 50 0 0 0 0 0 0 0 0 0
Liner in ETFE
DN200...2000 150 100 100 100 100 100 100 100 - -
Liner in Hard rubber
DN200...300 150 250 400 400 400 - - - - -
DN350...3000 150 500 600 600 600 - - - - -
Liner in PU
DN200...1800 1500 500 600 - - - - - - -
[inch] [psi] 104F 140F 158F 176F 194F 212F 248F 284F 356F
Liner in PTFE
3/8...3/4" 725 0 0 0 0 0 0 7.3 10.9 14.5
8...12" 725 7.3 10.9 14.5 14.5 14.5 14.5 14.5 14.5 14.5
14...24" 725 11.6 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5
Liner in PFA
1/10...6" 725 0 0 0 0 0 0 0 0 0
Liner in ETFE
8...72" 2176 1.5 1.5 1.5 1.5 1.5 1.5 1.5 - -
Liner in Hard rubber
8...12" 2176 3.6 5.8 5.8 5.8 - - - - -
14...120" 2176 7.3 8.7 8.7 8.7 - - - - -
Liner in PU
8...72" 21756 7.3 8.7 - - - - - - -
The manufacturer is not liable for any damage resulting from improper use or use for other than
the intended purpose.
Do a check of the packing list to make sure that you have all the elements given in the order.
Look at the device nameplate to ensure that the device is delivered according to your order.
Check for the correct supply voltage printed on the nameplate.
3.2.1 Vibration
Figure 3-4: Inlet when using 2 and/or 3 dimensional bends in front of the flowmeter
Inlet length: using bends in 2 dimensions: 5 DN; when having bends in 3 dimensions: 10 DN
3.3.3 T-section
3.3.4 Bends
3.3.7 Pump
Mount flow sensor either with signal converter aligned upwards or downwards.
Install flow sensor in line with the pipe axis.
Pipe flange faces must be parallel to each other.
3.4 Mounting
3.4.1 Torques and pressures
Tightening of bolts
Always tighten the bolts uniformly and in diagonally opposite sequence.
Do not exceed the maximum torque value.
Step 1: Apply approx. 50% of max. torque given in table.
Step 2: Apply approx. 80% of max. torque given in table.
Step 3: Apply 100% of max. torque given in table.
Observe without fail the local occupational health and safety regulations. Any work done on the
electrical components of the measuring device may only be carried out by properly trained
specialists.
Look at the device nameplate to ensure that the device is delivered according to your order.
Check for the correct supply voltage printed on the nameplate.
4.2 Grounding
The device must be grounded in accordance with regulations in order to protect personnel
against electric shocks.
Minimum requirements:
Size: DN10
Electrical conductivity: 200 S/cm
Signal cable: max. 50 m / 164 ft, type DS
Pressure
Process Analysis
Services