Terminations
Terminations Low and Medium Voltage
15
Terminations for paper and polymeric insulated cables 1 kV
L2
L1
L3
16
Selection tables for polymeric insulated cables 1 kV
Dimension L see table (L min = 450 mm) EPKT Termination only for MI cables
19
Indoor terminations for screened, paper insulated cables (MIND) with one metal
sheath per phase 10 kV, 20 kV and 35 kV
20
Outdoor terminations for screened, paper insulated cables (MIND) with one metal
sheath per phase 10 kV, 20 kV and 35 kV
Note: The solderless earth connection kit must be ordered separately. The EAKT kit includes roll springs, earth leads and protection
tubing or a breakout. The SMOE kit includes a Ligarex connection system (see also tools at page 109).
21
Indoor terminations for screened, paper insulated cables (MI) with one metal sheath
per phase 10 kV and 20 kV
min. 550
22
Long term testing of 10 kV paper cables
accessories type GUSJ and GUST at
Raychem products development
laboratories
23
Indoor terminations for flexible, screened, rubber insulated cables 6 kV
24
Outdoor terminations for flexible, screened, rubber insulated cables 6 kV
25
Indoor terminations for unscreened, 3-core polymeric insulated cables 6 kV and 10 kV
Solderless earth connection for cables with armour or copper tape shield
Nominal voltage Cross section Ordering description
Uo /U (kV) (mm2)
16 95 SMOE-60805
3,5/6
120 300 SMOE-60873
16 SMOE-60805
6/10 25 95 SMOE-60873
120 300 SMOE-62176
Note: The solderless earth connection kit must be ordered separately. It includes a roll spring and an earth lead.
Terminations for motor connection boxes are available on request.
26
Outdoor terminations for unscreened, 3-core polymeric insulated cables 6 kV and 10 kV
Solderless earth connection for cables with armour or copper tape shield
Nominal voltage Cross section Ordering description
Uo /U (kV) (mm2)
16 95 SMOE-60805
3,5/6
120 300 SMOE-60873
16 SMOE-60805
6/10 25 95 SMOE-60873
120 300 SMOE-62176
Note: The solderless earth connection kit must be ordered separately. It includes a roll spring and an earth lead.
27
Indoor terminations for screened, 3-core polymeric insulated cables 10 kV, 20 kV and 35 kV
Solderless earth connection for copper tape shielded cables with or without armour
Nominal voltage Cross section Ordering description for cables with tape shield
Uo /U (kV) (mm2) without armour with tape armour with wire armour
10 50 EAKT-1655
35 120 EAKT-1656 EAKT-1675-CEE01
6/10 95 240 EAKT-1657 EAKT-1676-CEE01 EAKT-1657 + EAKT-1643
240 500 EAKT-1658 EAKT-1677-CEE01 EAKT-1658 + EAKT-1645
25 70 EAKT-1656 EAKT-1675-CEE01
12/20 50 150 EAKT-1657 EAKT-1676-CEE01 EAKT-1657 + EAKT-1643
120 400 EAKT-1658 EAKT-1677-CEE01 EAKT-1658 + EAKT-1645
50 150 EAKT-1658 EAKT-1677-CEE01 EAKT-1658 + EAKT-1644
20/35 50 300 EAKT-1658 EAKT-1677-CEE01 EAKT-1658 + EAKT-1645
300 500 EAKT-1659
Note: The solderless earth connection kit must be ordered separately. It includes 3 roll springs and 3 earth leads, for cables with tape
armour in addition one larger roll spring. For cables with wire armour, the kit includes clamping rings, an earth lead and a sealing sleeve.
28
Outdoor terminations for screened, 3-core polymeric insulated cables
10 kV, 20 kV and 35 kV
Design of termination
The design and installation is the same as
D
for indoor terminations. In addition skirts
are installed onto the tubing (see table).
Solderless earth connections for cables
with tape shield or armour have to be
ordered separately.
Kits with the modification code -13
include mechanical lugs with a busbar
L connection hole for M12 connection
bolts, with code -17 for M16 bolts.
29
Indoor terminations for screened, 1-core polymeric insulated cables
10 kV, 20 kV and 35 kV
Design of termination
The design and installation is the same as
for indoor terminations. In addition skirts
are installed onto the tubing (see table).
Solderless earth connections can be
ordered separately. Kits with the modifi-
D
cation code -13 include mechanical
lugs with a busbar connection hole for
M12 connection bolts, with code -17
for M16 bolts.
Terminations for other cross sections, voltages and cable types are available on request.
32
Elastomeric outdoor terminations for screened, 1-core polymeric insulated cables
with wire screen 10 kV, 15 kV, 20 kV and 35 kV
Terminations for other cross sections, voltages and cable types are available on request.
33
Terminations for screened, polymeric insulated Filter Cables up to 150 kV D.C.
34
Terminations for screened, polymeric insulated cables for electrified Railway systems
25 kV A.C.