Nexus 1262 & 1272 Catalogue
Nexus 1262 & 1272 Catalogue
Nexus 1262 & 1272 Catalogue
Accu-Measure
Auto-Calibrating
Metrology
Nexus 1272
Nexus 1262
www.electroind.com
Email on Alarms
DNP 3.0 over Ethernet
Electro Industries/GaugeTech
MV90
Compatible
standard
pulse
accuracy.
Energy and Power Accuracy to Within 0.06%
Automatic Temperature
Drift Adjustments
4 Quadrant
measurement
The unit is a full four quadrant meter and gathers hour data
CT &PTCompensation
Received
kVAh in Each Quadrant
potential transformers.
Voltage Compensation
Q Hours
Multipoint Current
Compensation
Time of Use
The
1262/1272
Compensation
Better than 0.01%
Resolution
8 TOU Schedules
4 Seasons/Year
20 Year Calendar
Transformer
or Line Loss
Compensation
Loss Compensation adjusts
for both copper and iron losses
with a simple user setup.
to Many Hours
Predictive Demand
Thermal Demand
Cumulative Demand
Received, Max/Min
kVAR Demand, Delivered &
Received, Max/Min
01 kWh
Delivered
00001.66
08/03/10 16:46:45 1
Normal Mode
kWh Delivered and Received
screens. These slots can be allocated to any view mode with any number of
kVARh and kVAR Demand Delivered and Received for Each Register
Phase Angles
Harmonic Magnitudes
Firmware Versions
Meter Status
Phasor Diagram
Watts/VARs
Control Capabilities
ElectroLogic Provides User-definable
Control Outputs
Modbus RTU/ASCII
DNP 3.0
Optional Communications
10/100BaseT Ethernet
EIGs Nexus
Ethernet/Modem combo
Combination Modem
& Web Solution
This option allows you to access the meter
through the web and through a modem for dial-up
communication. Features include:
56k Modem
10/100BaseT Ethernet
Up to 136 Measurements:
64 Binary Inputs, 8 Binary Counters,
Email on Alarm
Per-point Basis
Low-Cost/High Functionality
Standard I/O
IRIG-B 1 msec Time Synchronization to
GPS Satellite Clock
4 Internal KYZ Pulse Outputs
8 KYZ Pulse/Status Inputs
WebExplorer
(Directly Host Metering Data)
Analog Outputs
Analog Inputs
KYZ Outputs
Relay/Alarm Outputs
WebXML
Creates Real Time Data in XML Format.
WebXML allows the Nexus meter to gather data
from the Nexus Host or through other meters and
put the data directly into an XML format. This allows
you to share data through the web with multiple
applications and create custom webpages, using
WebExplorer.
4
WebExplorer
WebXML
WebReacher
Webmod
(Open Architecture 3rd Party Integration)
Addresses
Later Investigation
(WebReacher)
Customized Programming
Webdnp
WebReacher
Meter 124
WebXML provides
totalized energy usage
Internet Explorer
WebMod TCP/IP
Web
M
od T
CP/I
P
P
TC
TC
P
We
bM
od
/IP
Java applets.
P
TC
Meter 115
od
/IP
eb
W
bM
We
/IP
od
Meter 31
(Up to 32 Devices)
Meter 87
Meter 14
WebAlarm
WebMod
WebDNP
Nexus 1272 Advanced Power Quality Analysis Pinpoints Electrical Reliability Issues
The processing capability and accuracy of the Nexus 1272 makes
it possible to gather power quality information with unmatched precision.
The Nexus 1272 is ideally suited for application on all critical loads. From
health care to micro-electronics, the 1272 has what it takes to capture every
anomaly. This insures that when there is a power problem, you have the
information required to act. All Power Quality logs are time stamped to the
nearest millisecond to insure accurate recording. The meter's Advanced
Download Logic collects only new data to minimize download times.
Quantity
Outage Detection
Waveform Log
The waveform recording capability of the Nexus 1272 is unparalleled by any meter.
Waveform records of this quality have historically been reserved only for transmission
lines. The power of the Nexus 1272 now makes this quality available to your critical
customers.
E xtraordinary Resolution through
16 bit A/D Input
Sample Rates from 16 to 512
Samples per Cycle
Total Recording Times over 100
Up to Six Channels
Voltage and Current Triggers
E xternal Event Trigger
Voltage Surge/Sag Recording
Current Fault Analysis
Seconds
CBEMA/ITIC Log
The separate CBEMA/ITIC Log captures all voltage transients
that fall outside these standards. The onboard log holds 1024 events.
AiReports
PQ Analysis
Communicator EXT
Fault Analysis
Records
Measures Waveform Traces
Nexus Monitor
At The Interchange
Point
The Nexus meter gives you
Recommends Corrective
Actions or Solutions
Prepares and Formats Report
At The Customer
Test Protective
Equipment
Formats
Accuracy
FORM
RATED VOLTAGE
HOOKUP
9S
0 to 277V
L-N
36S
0 to 277V
L-N
2 E, 4W, Wye
with Neutral
45S
0 to 480V
L-L
SWB2
0 to 277V
9A
0 to 277
L-N
Programmable
(Universal Forms)
A Base Form
PARAMETER ACCURACY
Voltage 0.02%
Current
0.05%
Frequency
0.001Hz
kW
0.06%
0.06%
0.10%
kVAR
0.10%
kVA
0.10%
PF
0.10%
Power Up
Power Down
Password Access
Password Modification
Two Historical
Trend Logs
or DNP)
Historical Trending
Energy)
I/O parameters.
Duration of Event
Millisecond Resolution
Replace Conventional
Chart Recorders
Events
Logging Specifications
Model
Memory
Historical
Log 11
Historical
Log 2 1
CBEMA /
ITIC 2
Out of Limit
Log 2
Waveform
Log 3
Output Log 2
Input
Log 2
System
Events 2
1272
1272
Standard
Advanced
85 Days
555 Days
133 Days
133 Days
512
512
1024
1024
63
95
256
256
1024
1024
1024
1024
1262
1262
Standard
Advanced
69 Days
480 Days
32 Days
133 Days
N/A
N/A
512
512
N/A
N/A
512
512
1024
1024
1024
1024
1
2
Event
Meter
Dials Out
on Event
with notification of events. When the modem option card is installed, the meter
also includes a gateway port. This allows the meter to act as a master for up to 7
additional meters and dial out on alarm for any of these meters.
RS485
Connection
Telephone
Dial-out
Modem
INP2
Server
Receives
Alarm
Server Provides:
Alarm Notification
Logging &
Download
Automated Alerts
Visual Alarm
Email Notification
Paging Notification
Dial-In Settings
Dial-Out Logic
9
Nexus 1262/1272
Switchboard Case Back View
Y K Z
CH1
4.38
(11.11
cm)
9.25
(23.5
cm)
K Z Y K Z Y K Z
| Y CH2
| CH3 | CH4 |
S (-) (+)
COM4
8.5
(21.6
cm)
S (1) (+)
Gateway
8 7 6 5 4 3 2 1 C
HIGH SPEED
L N PE
Power In
9.0
(22.9
cm)
Vc
Ia - Hi
0.19
(.048
cm)
6.85" (17.4
(173.99cm)
mm)
6.85
Nexus 1262/1272
Front View
Ib - Hi
Va
Ic - Hi
Vn
Lo
Lo
Lo
Vb
Nexus 1262/1272
Side View
1.10 (2.8cm)
0.63 (1.60cm)
1.31 (3.33cm)
6.96
(17.68
cm)
2.20
(5.6cm)
3.68 (9.35cm)
6.16 (15.64cm)
6.00 (15.24cm)
Nexus 1262/1272
A Base Front View
3.40
(8.63cm)
Nexus 1262/1272 A Base
Side View
0.87 (2.21cm)
4.23
(10.74cm)
10.17
(25.83cm)
2.00
(5.08cm)
7.00 (17.8cm)
10
6.18 (15.7cm)
Specifications
Wiring Diagrams
FORM: 9S (TRANSFORMER RATED)
SERVICE: WYE, 4WIRE
3 PTs, 3 CTs
Switchboard Mount
LINE
1
SERVICE: WYE, 4WIRE
3 PTs, 3 CTs
2
Y K Z
CH1
K Z Y K Z Y K Z
| Y CH2
| CH3 | CH4 |
S (-) (+)
COM4
S (1) (+)
Gateway
8 7 6 5 4 3 2 1 C
HIGH SPEED
L N PE
Power In
Vc
Ia - Hi
Ib - Hi
Va
Ic - Hi
Vn
Lo
Lo
Lo
Vb
LINE
Hi
lc Lo
Hi
CTs
lb Lo
Hi
la Lo
PTs
LOAD
LINE
Switchboard Mount
3
Y K Z
CH1
K Z Y K Z Y K Z
| Y CH2
| CH3 | CH4 |
S (-) (+)
COM4
8 7 6 5 4 3 2 1 C
HIGH SPEED
L N PE
Power In
Vc
Ia - Hi
S (1) (+)
Gateway
Ib - Hi
Va
Ic - Hi
Vn
Lo
Lo
Lo
Vb
LINE
Hi
lc Lo
Hi
CTs
la Lo
PTs
LOAD
LOAD
11
Specifications
SENSE INPUTS:
CURRENT (ac)
Transformer (CT) rated
2 or 3 current inputs depending on Form
(Ia, Ib, Ic)
Class 2 1A nominal, burden [email protected]
Class 10, 20 5A nominal, burden
0.0125VA@25A
0.1% of nominal pickup current
120% over range of Meter Class
Current surge withstand (at 23C) - 100 Amps
for 10 seconds, 300 Amps for 3 seconds,
500 Amps for 1 second
VOLTAGE (ac)
Blade powered unit, standard voltage (option S):
480V max Phase to reference (Va, Vb, Vc to Vref).
Burden total 12VA max (including power supply)
600V max Phase to Phase (Va to Vb, Vb to Vc,
Vc to Va)
Blade powered unit low voltage (option LV):
69V max between Vref and Va, Vb, Vc inputs.
Burden total 12VA max (including power supply)
120V max between Va, Vb, Vc inputs
Externally powered units (options SE, DE):
480V max between Vref and Va, Vb, Vc inputs.
Burden 0.33VA@576V
600V max between Va, Vb, Vc inputs
Input impedance 1Mohm/phase
20% over range of rated voltage
2V pickup voltage
STANDARD COMMUNICATIONS
LCD Display
IR Port
Two RS485 Serial Ports
Modbus RTU, Modbus ASCII, DNP 3.0
Data Speeds of up to 115k bps
Eight High-Speed Input Channels
INTERNAL 4ch
SOLIDSTATEOUTPUTS (kyz)
Type: Form A or C
On Resistance: 23-35
Peak Voltage: 350V DC
Continuous Load Current: 120mA
Peak Load Current: 350mA (10ms)
Ordering Information
APPROVALS
IEC 60687 - KEMA Certified
IEC 62053-22 - KEMA Certified
California ISO
NY State Public Service Commission
USDA Technical Standards Committee Rural
Development Unit
NMi - Brazil
CEEE - Brazil
Union Fenosa - Spain
CAM - Endesa Chile
China EPRI
North China EPRI
Northwest China EPRI
East China EPRI
ATS - Korea
CLOCK TIMING
Internal Clock Crystal - Accuracy Better than
2 Minutes per Month
IRIG-B Input for Synchronizing to External GPS
Clock Signal - Accuracy Better than 1 msec
per Month
Line Sync - Accuracy Better than 1 Second
per Month
ENVIRONMENTAL
Operating Temperature: (-40 to +85)C
Display Temperature: (-20 to +60)C
Raintight Lexan Cover (Socket)
Temperature Specifications to Indirect Light
SENSING
Accu-Measure Technology
16 bit A/D Inputs
True RMS
8 Channel Sample & Hold
MEMORY
All Meter Setup Parameters, Measurements
& Logs Contained in Nonvolatile RAM
SECURITY
Hardware Lock Secures Meter Settings
Two 10-Character Passwords
One Password Controls Access to Read
Meter Digitally
Separate Password Controls Access to
Program Meter
OPTIONAL COMMUNICATIONS
56K Modem with Dial-Out Capabilities
Internal 10/100BaseT Rapid ResponseEthernet
Modem/Ethernet Combo Card
Modbus TCP and DNP LAN/WAN
COMPLIANCE standards
ANSIC12.20
Accuracy
ANSI/IEEE C37.90.1 Surge Withstand
ANSI C62.41
Surge Immunity
IEC/CISPR 14-1
Continuous EM Disturbance
IEC 61000-4-2 (EN 61000-4-2 / IEC 801-2):
Electrostatic Discharge
IEC 61000-4-3 (EN 61000-4-3 / IEC 801-3):
Radiated EM Field Immunity
IEC 61000-4-4 (EN 61000-4-4 / IEC 801-4):
Electric Fast Transient
IEC 61000-4-5 (EN 61000-4-5 / IEC 801-5):
Surge Immunity
IEC 61000-4-6 (EN 61000-4-6 / IEC 801-6):
Conducted Immunity
IEC687
Voltage Dips and Interruptions
IEC60687
Class 0.2 Accuracy
IEC62053-22
Class 0.2 Accuracy
IEC62052-11
General Requirements,
Mechanical Properties,
Climactic Influences
Weight:
Socket: 10 Lbs
Switchboard: 16 Lbs
Dimensions:
Socket: 13" x 10" x 11" Switchboard: 16" x 14" x 11"
Model
Memory
Form
Class (Amps)
Frequency
Power Supply1
Optional
Communication
Option
Numbers:
Example:
1272
1272
45S
S
9S
Std
20
2
Amps
50
DE
INP200
50
50 Hz
S
Std Blade Powered
X
No Optional Com
1262
A
36S
10
60
Adv
Amps
60 Hz
SE
Std Ext
102-270V AC/DC
INP2
Modem
with Dial-Out
45S
20
DE
Amps
DC Ext
18-60VDC
INP200
10/100BaseT Ethernet
SWB2
LV INP202
(Switchboard) 69VAC
Modem &
Blade Powered
Ethernet Combo
(No Dial-Out)
9A
(A Base)
1 Switchboard Meter Only Supports SE or DE Options.
Accessory Options
O PTIO N A L I / O M OD UL E S
1mAON4
4 Analog Outputs, 0-1mA
8 Analog Outputs, 0-1mA
1mAON8
4 Analog Outputs, 4-20mA
20mAON4
8 Analog Outputs, 4-20mA
20mAON8
4RO1
4 Relay Outputs
4 Solid State Pulse Outputs
4PO1
8AI1
+/- 0-1mA, 8 Analog Inputs
8AI2
+/- 0-20mA, 8 Analog Inputs
8AI3
+/- 0-5VDC, 8 Analog Inputs
8AI4
+/- 0-10VDC, 8 Analog Inputs
8DI1
8 Status Inputs, Wet/Dry
POWE R OP TI O NS
PSIO
BAT1
S O F TWARE O P TI O NS
COMEXT3.1C
Communicator EXT 3.0 for Windows
Single-Computer License (One Site)
COMEXT3.MC
AIEXT.1C
M OU N T ING O P TI O NS
MBIO
AIEXT.MC
DISEXT.1C
Electro Industries/GaugeTech
DISEXT.MC
Dial-In Server Multi-Computer License
(One Site)