CoCoS-EDS

Engine Diagnostics System


Quick Reference

MAN Diesel

MAN Diesel A/S


Teglholmsgade 41
DK-2450 Copenhagen SV
Denmark
Telephone: +45 33 85 11 00
Telefax: +45 33 85 10 30
[email protected]

Copyright MAN Diesel A/S. Reg. No. 39 66 13 14


Reproduction permitted provided source is given
Subject to modification in the interest of technical progress
3520-0005-00ppr Feb 2007

 (ofDiesel
20) - a member of the MAN Group
MAN

MAN Diesel

Engine Diagnostics System


What & How:

Change to Chief or Crew Mode ..1


Make Performance Measurement ..2

Contents

CoCoS-EDS Quick Reference

Input / View Performance Data ..3


Perform Manual Diagnostics Evaluation ..4
View Diagnostic Details / History ..5
Store Line Recorder Data Dump ..6
Make Measurement from Line Recorder Zoom ..7
Calculate Fuel Oil Consumption ..8
View Load Diagram ..9
Monitor Parameters Over Time ..10
Copy Measurements to Excel ..11
Zoom with Mouse ..12
View / Set Display Attribute ..13
Print Pages to PDF..14

View System Log-Errors & Warnings ..17


Set Up New Display Group ..18
Modify Existing Display Group ..19
Export / Import Measurements ..20

Crew:
System
Overviews

Training ..21
System Overview: EDS & PMI ..22
Mode Indicators: On-line & Off-line ..23
Function & Keyboard Shortcuts ..24
Click Section to Open

CoCoS-EDS Quick Reference

Input / Adjust Operating Hours ..15


Special
Maintenance: Assign LCV, Density & Static Values ..16

 (of 20)

MAN Diesel

What & How

Change to Chief or Crew Mode

Change to Chief mode, by selecting:


System > Enter Password... in main menu
and typing Chief (not chief nor CHIEF)
Change back to standard user, i.e. Crew mode, by
selecting:
System > Passwords > Back in main menu.

Make Performance Measurement

A. Open PMI Analyzer if not already running


and make performance measurement based
on one of the following:
Recent PMI measurement In Crew
mode select:
Measurements > Read Pressure Curves
and click OK.
EDS automatically merges PMI data with
Trend data with same the time stamps.

CoCoS-EDS Quick Reference


 (of 20)

Old PMI measurement Note time stamp


of old PMI measurement and select:
Monitoring > Line Recorder
or click tool button. Next zoom in on the
line recorder measurement consistent with
date and time of old PMI measurement (i.e.
drag mouse over it as in section 12) and
click the green tool button2.
Now go to Chief mode and select:
Measurements > Read Pressure Curves1
Click Read Old Curves, select PMI
measurement and click OK.
Click OK and Add to Current.
Verify Time stamps match and click OK.

1 & 2

See Notes on next page

MAN Diesel

Note that the mode indicator has changed


colour to red in upper right corner of EDS. See
section 23.

What & How

Without PMI measurement select:


Measurements >
Manual Input > Filtered Values
EDS now returns to the off-line mode to show the
measured values in the Standard Report.

B. Input off-line values from local gauges, such as


Pump/VIT index, VIT air pressure, ship speed, etc.,
in the report by clicking in the appropriate field and
keying in the correct value from the keyboard.
i Manually input values are marked with the

adjacent sign. If a manual value is deleted its


field will be reset to its original on-line value.

C. Store measurement by selecting:


Measurements > Store Measurements...,
Go to Chief mode and key in or set correct
date and/or operating hours for the measurement and click Save followed by Close.

If the PMI measurement lies


outside the line recorder time
span, a compatible trend measurement with similar time
stamp can be chosen by clicking on its grey indicator line
in the Trend > Time Plot view.
Thereafter, select the entry in
the dialogue that is opened
and click Load.

CoCoS-EDS Quick Reference

Notes:
1
EDS might prompt you to save an earlier measurement. Often it can be ignored, i.e click No to
continue.

 (of 20)

MAN Diesel

What & How

Input / View Performance Data

A. Open Performance Report sheets:


Select Reports >
1 Performance_Sheets ....
If necessary:
Use % Box in Toolbar to resize display and/or click tool button when in
Chief mode.
Click tabs shown to view other pages
in report.
B. Switch to Off-line mode by double-clicking the mode indicator in the upper right
corner of EDS see 'Mode Indicator Table',
section 23.

Off-line

EDS is now ready for manual input of measurement


data.
C. Select relevant field and input data:
Use Tab (or Shift Tab) keys to step forward (or
back) and type in text from keyboard.
i Switching back to on-line mode will not de

CoCoS-EDS Quick Reference


 (of 20)

lete nor save data. Store measurement to save it


see section 2 c.

Perform Manual Diagnostics Evaluation

A. Select:
Measurements > Measurements ...
and from the dialogue load the stored engine
performance measurement to be diagnosed.
See Note1 in section 2.
B. Select:

Measurements > Diagnostics.

EDS now evaluates the performance according to


the Instruction Book for the engine (Operation

MAN Diesel

What & How

Chapter 7) and returns to the Diagnosis overview


to give:
diagnosis headlines if any to view details see
section 5B, or
status line prompt if no irregularities
are present.

View Diagnostic Details / History

A. View current on-line diagnosis (if any)


Select:
Diagnosis > Pending,
or double-click the on-line diagnosis
status indicators at bottom right
of screen see table opposite.

B. Right-click diagnosis of interest and select one of


the following in pop-up menu to:

C. View past Diagnosis Select:


Diagnosis > Closed
for a bar view of diagnosis history.

Store Line Recorder Data Dump


A. Open the line recorder database:
System > Line Recorder Database
B. Click Add button to store new line
recorder dump.

CoCoS-EDS Quick Reference

acknowledge diagnosis, or
view diagnosis values (see Note1,
section 2), or
view Instruction Book advice for
restoring normal operation.

 (of 20)

MAN Diesel

What & How

i Manual records are coloured green,

auto-matic records are black.

C. Click the new record to select it.


D. Click in comment field, key in a suitable
description and click Update to store and
OK to close.

Make Measurement from Line Recorder Zoom

A. Open line recorder database:


System > Line Recorder Database...
B. Select desired record/dump and click
Show.
C. Define measurement period by zooming
with mouse see section 12.
D. Click green tool button.
i EDS returns to Off-line mode to show standard

report giving average values for the zoomed period. The start/stop times (period) are also stored.

E. Remember to store measurement if needed


see section 2C.

CoCoS-EDS Quick Reference


 (of 20)

Calculate Fuel Oil Consumption

A. Make Performance Measurement see section 2.


B. Open Performance Report for above
measurement and click Consumption
link or relevant page tab.

or

C. Input/verify fuel properties and flow meter/mass


counters.
D. Click Performance Sheet link to go
to Performance Report, page 1.
E. Remember to store measurement if needed
see section 2C.

MAN Diesel
9

A. Go to the Trend view:


Trend > Time Plots or click tool button.
B. Do one or both of the following:
Right-click in the view to open the
Display Attributes dialogue and
check at least one of the check
boxes opposite, or

What & How

View Load Diagram

Mouse zoom to define the period of interest


see section 12.
C. View Load Diagram:
Monitoring > Load Diagram
i The dots shown in the Load Diagram are the

points selected in the Trend view.

Monitor Parameters Over Time

10

A. Go to Trends view:
Trend > Time Plots
B. Right-click in any operating value plot to open its
Display Attributes dialogue and set up its display.

C. Click tool button to reset (i.e. un-zoom)


display and view all trend entries.

Copy Measurements to Excel


A. Go to the Performance Table view:
Monitoring > Performance Tables
and select appropriate page tab.

11

CoCoS-EDS Quick Reference

As an example select Value option


opposite to see how the magnitude
deviates from the nominal value over
time or set Ambient Conditions as
shown to see equivalent ISO values.

 (of 20)

MAN Diesel

What & How

B. Right-click with mouse in any field to open Measurement ... dialogue.


C. Use the mouse to select one or more individual
measurements:
Left-click to select single entry
Press Shift and left-click start and end
to select group of entries, or
Press Ctrl plus left-click to select non
adjacent entries.
D. Click Load button to display selected data
in the performance table.
E. Press Ctrl + C to copy.
i EDS copies all values in performance table to

clipboard in comma separated format (CSV).

F.

Open an Excel sheet, press Ctrl + V or choose


Edit > Paste to paste copied data directly into the
sheet.

Zoom with Mouse


The Zoom function works with:

CoCoS-EDS Quick Reference


10 (of 20)

Line Recorder (Sideways & Up/Down)


Model Curves (Sideways & Up/Down)
Trends (Sideways & Up/Down)
Pressure Curves
Load Diagram (Sideways & Up/Down)
Bar Charts (Up/Down only)
Closed Diagnosis (Sideways only)

12

MAN Diesel
A. Click and hold down left mouse button
while moving mouse:
sideways for zooming time period, or
up or down for zooming magnitude.
B. Release mouse button to magnify (i.e. zoom in) on
defined area.

What & How

To zoom:

Click tool button to zoom out and restore


view to original size.

View / Set Display Attributes

13

In most views right-clicking the mouse within a


curve opens a Display Attributes dialogue box.
Examples of some of the attributes that may be
chosen are shown below, but may differ to suit the
particular view:
Monitor particular cylinders,
T/Cs or bearings, etc.

Set display limits.

Show Actual or ISO corrected


ambient conditions.

CoCoS-EDS Quick Reference

View time as running hours or


calendar time.

11 (of 20)

MAN Diesel

What & How

Show Actual values or deviation


from nominal.
i Trend data are often most relevant in devia

tion from nominal (Act/Nom. Delta) value.

Print Pages to PDF


A. Select:

14

System > Print ...

B. Select a PDF Printer / Writer in the


'Print' dialogue.
i The Cute PDF Writer is supplied as standard

with EDS. It is freeware available from www.


cutepdf.com.

C. Click Print and select or create a folder for


the pdf file in the 'Save PDF File' dialogue.
Next type in a name for the file or accept the default file name 'EDS_ Printing pdf'.

CoCoS-EDS Quick Reference


12 (of 20)

D. Click Save to copy the current measurement or report sheet that is displayed to the
specified folder ready to be archived or sent
as e-mail.

Continued >

MAN Diesel
15

A. Change to Chief mode and open Operating


Hours dialogue:
Tools > Setup > Operating Hours...
B. Key in operating Hours plus minutes and
click OK.
C. Verify that the counter at the bottom left of
the screen shows the same operating hours.

Assign LCV, Density & Static Values

16

Special Maintenance

Input / Adjust Engine Operating Hours

A. Change to Chief mode and open Static Values


dialogue:
Tools > Setup > Static Values....
B. Click '+' symbols to open main parameter lists at
top of dialogue. Double-click individual parameters to select and add them to the static value list.
C. The appropriate static values may now be
keyed-in in the static value list at the bottom
of the dialogue. Press the Enter key at the
end of each entry.
D. Click OK to save your data and exit.

i Static values are marked by a Padlock

symbol.

View System Log Errors & Warnings


A. Check for errors and warnings:
Look for status line prompts at bottom
right-hand corner of screen, e.g.

17

CoCoS-EDS Quick Reference

E. Click the Standard Report tool button and


verify that the correct static values have
been input in the Standard Report.

13 (of 20)

MAN Diesel

Special Maintenance

B. Open system log:


Select Tools > System Log or doubleclick status line error or warning prompt.
C. Copy and send details:
Make screen capture of system/warning
log by pressing Prt Scr key on keyboard
and pasting via clip board into word
processing or paint application.
Copy SYSTEM_ERROR.EDS file in EDS
directory.
Send above information to MBD if troubleshooting is necessary.
D. Acknowledge error and warnings:
Right-click within error/warning
details field and click pop-up button to acknowledge and close.

Set Up New Display Group


A. Select the view requiring a new
display group, e.g. Line Recorder,
Standard Report, Trend, etc.

CoCoS-EDS Quick Reference


14 (of 20)

B. Change to Chief mode and open


'Display Groups' dialogue:
Tools > Customise
> Display Groups
C. In Operating values field, doubleclick one or more parameters of
interest in turn to highlight them and
click the Select button.
A new group is created at the bottom
of Display Groups field.

18

MAN Diesel

Modify Existing Display Group


A. To edit a Display Group:
Select (click) any group other than the
one to be modified.
B. Change to Chief mode and open Display
Group dialogue:
Tools > Customise > Display Groups...

19

Special Maintenance

D. Click the Ready button to close the


dialogue and use the Page Up/Down
keys or tabs to select the last page
containing the new display group.

C. Click the group to be modified in the Display group field and click the Edit button.
D. To add new parameters:
Double-click one or more items in turn in
the Operating value field above the 'Display group' and click the Add button.
The parameters are added to the appropriate group in the Display group field.

Alternatively, to delete an entire group


click OK to return to the group selection view, click the group to be deleted
and then click the Delete button.
F.

Click the Ready button to close the


dialogue and use the Page Up/Down
keys or tabs to select the page containing the modified display group.

i EDS cannot change the active display group indicated by a red page number. To change group you
must select another page.

CoCoS-EDS Quick Reference

E. To remove parameters:
Click to select a parameter in the Display
group field and click the Delete button.

15 (of 20)

MAN Diesel

Special Maintenance

Export / Import Measurements

20

A. Open Import/Export dialogue:


Measurements
> Import/Export Measurements ...
B. Open/Create archive:
Open existing Archive file, or
Create new one by clicking New button.
Key in relevant file name for archive and
click Save button.
i For easy location save the file in the root of

the CoCoS EDS directory.

C. Export/Import measurements:
Export single or all measurements from
EDS (left-field) to Archive (right-field) by
clicking buttons opposite
Import single or all measurements from
archive to EDS to Archive by clicking ...
D. Click OK button to finish.

CoCoS-EDS Quick Reference


16 (of 20)

Continued >

MAN Diesel
21

Operating values shown in standard report


User Access levels/password (Chief & Crew level)
Check limits (alarm limits), Display limits
Actual and nominal values (from model curves)
EDS filtering
On-line and off-line modes of EDS
Transfer on-line to off-line data (i.e. store measurements)

2.

Views
Engine Overview, Standard Report, Line Recorder
Characteristic Maps (Model Curves / Nominal Values)
Bar Charts, Load Diagram, Performance Curves
and Tables
Display groups, attributes, customising groups

3.

Trend operation
Short trend, Long trend
Diagnostic trend & Manual trends (measurements)

4.

Measurements
Line recorder zoom, filtered and non filtered values
Updating measurements with local readings and
PMI data
Storing and loading measurements
Printing measurements
Exporting to file, exporting to Excel

5.

Adjusting values
Fuel oil properties and static values
Engine running hours

6.

Line recorder measurement dumps

7.

Diagnosis
Pending, closed
Triggering and acknowledgement
Measurement forced diagnostic calculation

8.

Backup and restoration of data

CoCoS-EDS Quick Reference

1.

Crew Training

Crew Training

17 (of 20)

MAN Diesel

M/E

TDC,
Trigg

To ECS1

TDC,
Trigg

#2

ECR PC

Software:
CoCoS-EDS
PMI

CoCoS-EDS Quick Reference

M/E: Main Engine


A/E: Auxiliary Engine
EDS: Engine Diagnostics System
PMI: Pressure Measurement Instrumentation
CoCoS: Computer Controlled Surveillance

Converter BOX

MAN B&W Diesel A/S

System Connections CoCoS-EDS and PMI


AMS Console
MOP A*

AMS: Alarm Monitoring System


ECS: Engine Control System1
MOP: Main Operating Panel
ER: Engine Room
ECR: Engine Control Room

MOP B1

AMS PC(s)

ER ECR

AlphaLub (if appl)

Encoder

#1

#n

Optional MAN B&W A/E

ME engines only

A/E

1
2

System Overviews

18 (of 20)

22
System Overview: CoCoS-EDS with PMI

MAN Diesel

Mode Indicator

Mode indicator
Stored File name
on right of EDS title bar
on
/Directory
double-click Non-Filtered
Disk
On-line

Non-Filtered

23

> Filtered > Off-line

Latest values: data acquisitioned, calculated and static

No

CM.eds

Off-line

Manual Measurement from


non filtered, filtered or blank

No

Cycle memory
measurement

Manual measurement from


Line Recorder Zoom

No

Line recorder
measurement

Manual measurement with


Zoom from Line Recorder
dump, i.e. from "emergency
stop"

No

Pressure
measurement

Measurement updated from


PMI database

No

PM.eds

Line recorder
measurement

Static Line Recorder Dump


View so-called "Base line" or
"Cycle memory" dump

Yes

/Linerec

Measurement from Measurement Trend database

Yes

MT/
MT.eds

Measurement

No

Diagnosis
measurement

Auto generated measurements


with operating values from a
Diagnosis

Yes

diag.eds

Short-Trend
entry

Auto generated measurements


with Short-Trend operating
values from Trend view

Yes

/ST

Long-Trend
entry

Auto generated measurements


with Long-Trend operating
values from Trend view

Yes

/LT

Reference
curve point

Measurements for model


curves generation loaded from
Characteristic Map view

Yes

MC.eds

CoCoS-EDS Quick Reference

Filtered values acquisitioned,


calculated and static according to EDS filter function

Off-line

Filtered

System Overviews

Mode Indicators: On-line & Off-line

19 (of 20)

MAN Diesel
Function & Keyboard Shortcuts

24

Ctrl

Alt

Esc
F1

F2

F3
F4

Pending
Diagnosis

Trend
Curves

F7

F8

Acknowledge
System Error

Emerg. Stop Analysis


=
Line Recorder Database

System Log

Run
Diagnostics

Acknowledge
Diagnosis

View
Closed
Diagnosis

Store
Measurement

Measurements
Database

Line
Recorder
Zoom

Exit
EDS*

Print

F5
F6

Arrange
Windows
Vertical
View
Grid
Restore
View
Engine
Overview

F9

Cascade Windows

Arrange
Icons

Open
New View

Filtered Values

Off-line Values

Filtered

Off-line

Non Filtered
Values
Non-Filtered

Next
Window

Bar
Charts

Standard
Report

View
Pressure
Curves

Restore
Previous
Zoom
Performance
Tables

F11

Installation
Report
User's
Guide

Close
Engine*

Arrange
Windows
Horizontal

F10

F12

Shift
Toggle Full Screen

Setup Engine
Operating Hours*

Line
Recorder
Read
Pressure
Curves
Model
Curves

Performance
Report
Channel Cal.*
(1st data Acquisition
Protocol)

Setup
Static
Values

* <Chief> mode only


Example: Press Ctrl + F2 to Run Diagnostics on Performance Measurement

Copyright MAN Diesel A/S. Reg. No. 39 66 13 14


3520-0005-00ppr Feb 2007

You might also like