Module - 8 Lecture Notes - 2 Water Distribution Systems
Module - 8 Lecture Notes - 2 Water Distribution Systems
Module - 8 Lecture Notes - 2 Water Distribution Systems
Distribution Systems
Pipes: These are the principal elements in the system. The flow or velocity is usually
described using Hazen Williams equation
(1)
where V is the average flow velocity. CHW is the Hazen Williams roughness
coefficient, R is the hydraulic radius and Sf is the slope.
In terms of headloss hL, the above equation can be expressed as,
hL
KLQ1.852
1.852 4.87
CHW
D
K p Q1.852
(2)
where L is the length of the pipe, D is the diameter and Q is the flow rate.
Headloss can also be determined using Darcy Weisbach equation as
hL
L V2
D 2g
8 fL
Q2
2
gD 2
K pQ 2
(3)
where f is the friction factor (determined from Moodys diagram) and g is the
acceleration due to gravity.
M8L2
Water Resources Systems Planning and Management: Water Resources Systems Modeling Water
Distribution Systems
(ii)
Node: Junction nodes are connections of pipes to transfer the water. The diameter of
pipe is changed at these nodes. Fixed grade nodes is where pressure and elevation are
fixed i.e., reservoirs, tanks etc.
(iii) Valves: These are used to vary the head loss or to control the flow.
(iv) Tanks: It stores water and acts as a buffer by storing water at low demands and
releasing at high demands.
(v)
SIMULATION OF NETWORK
The flow distribution through a network should satisfy the conservation of mass and
conservation of energy. Consider the network structure in Figure 1 with 6 pipes and 5 nodes.
750
200
1
Loop 1
Loop 2
350
200
Fig. 1
Conservation of mass: Flow at each junction nodes must be conserved
Q in
out
Qext
(4)
where Qin and Qout are the flows in and out of the node respectively and Qext is the external
supply or demand.
Conservation of energy: For each loop, energy must be conserved i.e., sum of head losses
should be zero.
hL i . j
D Nagesh Kumar, IISc, Bangalore
H pump
(5)
M8L2
Water Resources Systems Planning and Management: Water Resources Systems Modeling Water
Distribution Systems
where hLi,j is the head loss in the pipe connecting nodes i and j and Hpump is the energy added
by the pump (if any). hLi,j can be determined using either eqn. 2 or 3.
Energy must be conserved between the fixed grade nodes which are points of known head
(elevation plus pressure head).
EF
hLi , j
H pump
(6)
If the number of pipes in the network is NL, number of junction nodes is NJ and number of
fixed grade nodes is NF, then total number of equations will be NL + NJ + (NF -1).
The set of equations obtained can be solved by any iterative techniques like Hardy-Cross
method, linear theory method and Newton - Raphson method.
Hardy-Cross method
In this method, the loop equation (eqn. 5) in terms of flow is used. The loop equations are
transformed into so called Q equations in the form
K p ,i , j Qi , j
Qi , j
(7)
i,j
hL ,i , j
K p ,i , j Qi , j
Qi , j sign Qi , j
Qi , j
(8)
i,j
K p ,i , j Qi , j
i, j
Qp
nK p ,i , j Qi , j
n 1
(9)
i, j
First a flow distribution is assumed across the network. Then the correction Q as given in
eqn. 9 is applied in a particular loop p. The numerator in eqn. 9 is the algebraic sum of
headloss in loop p taking care of the sign of the flow. If clockwise flows are taken positive,
then the corresponding headlosses are positive. The same is applicable while applying
M8L2
Water Resources Systems Planning and Management: Water Resources Systems Modeling Water
Distribution Systems
correction also i.e., Qp is added to flows in the clockwise direction and subtracted from
flows in counterclockwise direction.
Example:
Consider the pipe network shown below. The friction factor = 0.2. Determine the flow rate in
each pipe.
L = 1500 m; D = 0.6 m
L = 1200 m;
D = 0.7 m
L = 1200 m;
D = 0.7 m
L = 1500 m; D = 0.8 m
1 m3/s
E L = 1500 m; D = 0.7 m
L = 1500 m; D = 0.7 m
0.5 m3/s
L = 1200 m;
D = 0.7 m
2.5 m3/s
1 m3/s
Solution:
Step 1: Determine the K values in eqn. 3
hL
8 fL
Q2
2
2
gD
KAB = 3.88;
KQ 2 where K
8 fL
2
gD 2
Loop 1
1 m3/s
1 m3/s
Loop 2
0.5 m3/s
0.5 m3/s
1 m3/s
1.5 m3/s
0.5 m3/s
2.5 m3/s
0.5 m /s
1 m3/s
D
1 m3/s
M8L2
Water Resources Systems Planning and Management: Water Resources Systems Modeling Water
Distribution Systems
Q1
2
1 K AF Q AF
2 K AF Q AF
2
K FE QFE
K FE QFE
2
K BE QBE
K BE QBE
2
K AB Q AB
K AB Q AB
2
2
2
2
1 4.05 1 5.06 1 4.05 0.5 3.88 1.5
2 4.05 1 5.06 1 4.05 0.5 3.88 1.5
0.0187
Q2
2
2
2
2
1 4.05 0.5 5.06 0.5 4.05 0.5 6.89 1
2 4.05 0.5 5.06 0.5 4.05 0.5 6.89 1
0.2088
M8L2
Water Resources Systems Planning and Management: Water Resources Systems Modeling Water
Distribution Systems
750
200
1
Loop 1
3
5
Loop 2
2
3
350
200
M8L2
Water Resources Systems Planning and Management: Water Resources Systems Modeling Water
Distribution Systems
These 2 eqns. along with the 4 mass conservation eqns. can be solved to obtain 5 unknown
discharges.
OPTIMIZATION OF WATER DISTRIBUTION SYSTEMS
Simulation of distribution networks as discussed above helps to determine the hydraulic
parameters such as pressure heads, tank levels etc. These models are unable to determine the
optimal or minimum cost system. In addition to the cost minimization, the typical goals of
water distribution systems problem in designing pipe system can be:
A) Meeting the household demands.
B) Meeting the required water pressure at all nodes of the distribution system.
C) Optimal positioning of valves.
Therefore, designing water distribution system is a multiobjective problem, which is also
characterized by nonlinearity resulting from the simulation model.
Since the main purpose of a water distribution system is to supply according to the demands
with adequate pressure, a typical optimization problem will be to minimize the systems cost
while meeting the demands at required pressures. Hence optimization problem can be stated
as:
Minimize : Total cost (Capital cost + Energy cost for pumping water throughout the system)
Subject to:
(i)
Hydraulic constraints
(ii)
M8L2