The document describes various types of circuit breakers and switches including their ratings, dimensions and accessories.

Inverse time circuit breakers, instantaneous trip circuit breakers, motor disconnect switches and molded case switches are described.

Dimensions are provided for the rotary drive, door interlocking handle, remote control drive, cable lug and side wall operator for type NZM 7.

Circuit Breakers

Disconnect Switches, Molded Case Switches

Return To MAIN INDEX

Overview

8/2

Instantaneous Trip Circuit Breakers, NZMH 4-...-OBI-CNA


Motor Disconnect Switches, NZMH 4-...-CNA
Accessories

8/4
8/5
8/6

Inverse time Circuit Breakers, NZM(H) 6(B)-.../ZM6A-...NA


Instantaneous Trip Circuit Breakers, NZM(H) 6(B)- OBI-CNA
Motor Disconnect Switches, NZM(H) 6(B)-../ZM6-...-CNA
Motor Disconnect Switches, N 6-...-CNA
Accessories

8/12
8/13
8/14
8/15
8/16

Inverse time Circuit Breakers, NZM(H) 9-.../ZM9A-...NA


Instantaneous Trip Circuit Breakers, NZM(H) 9-...-OBI-CNA
Motor Disconnect Switches, NZM(H) 9-../ZM9-...-CNA
Motor Disconnect Switches, N 9-...-CNA
Accessories

8/22
8/23
8/24
8/25
8/26

Inverse time Circuit Breakers, NZM 12-.../ZM12(A)(V)-...NA


Motor Disconnect Switches, N 12-...-CNA
Accessories

8/32
8/33
8/34

Overview NZM 7.....-NA


Inverse time Circuit Breakers, NZM 7(A)-...S-NA(-M8)
Molded Case Switches, NZM 7-...-NA(-M8)
Accessories

8/40
8/44
8/45
8/46

125 A

250 A

Circuit Breakers
Disconnect Switches, Molded Case Switches

80 A

1000 A

150 A

600 A

Overview NZM 10.....-NA


Inverse time Circuit Breakers, NZM 10-...(N)(S)(H)-NA
Instantaneous Trip Circuit Breakers, NZM 10-...OBI-CNA
Molded Case Switches, NZM 10-...-N/B-NA
Components for NZM 10...-NA Circuit Breakers
Accessories

8/54
8/58
8/60
8/61
8/62
8/64

Trip Curves
Technical Data

8/72
8/77

Dimensions

8/84

For Immediate Delivery call KMParts.com at (866) 595-9616

8/1

Circuit Breakers Type NZM...-(C)NA


Ratings Overview

UL / CSA / CE / IEC/EN 60 947

Inverse Time Circuit Breakers

Frame Rating

UL/ CSA Interrupting Ratings

kA RMS SYM @

Amps

240 VAC

480 VAC

600 VAC

NZM 6B-.../ZM 6A-...-NA

15 - 125

25

25

14

NZMH 6-.../ZM6A-...-NA
Fuseless Current Limiting

15 - 125

100

65

25

NZM 7A-...N-NA1)

25 - 150

65

25

NZM 9-.../ZM 9A-...-NA

70 - 250

30

25

18

NZMH 9-.../ZM9A-...-NA
Fuseless Current Limiting

70 - 250

200

85

42

NZM 10-...N/ZM 10(A)-...-NA


NZM 10-...S/ZM 10(A)-...-NA

200 - 600
200 - 600

65
100

42
65

35
42

NZM 10-...H/ZM 10(A)-...-NA


Fuseless Current Limiting

200 - 600

200

100

50

With trip delay feature


for selectivity in networks
NZM 10-...N/ZM 10V(A)-...-NA
NZM 10-...S/ZM 10V(A)-...-NA

200 - 600
200 - 600

65
100

42
65

35
42

NZM 12-.../ZM 12(A)-...-NA2)

300 - 1000

65

65

50

With trip delay feature


for selectivity in networks
NZM 12-.../ZM 12V-...-NA2)

300 - 1000

65

65

50

Thermal-Magnetic Trip
UL 489/CSA 22.2 No. 5.1; IEC/EN 60 947-2

Circuit Breakers
Disconnect Switches, Molded Case Switches

Solid State Trip


UL 489/CSA 22.2 No. 5.1; IEC/EN 60 947-2

1) Type NZM 7... currently UL/CSA only. IEC 60 947-2 Conformity in preparation.
2) Type NZM 12... UL/CSA only.
All Inverse time Circuit Breakers are UL Listed and CSA Certified, in compliance with IEC/EN 60 947-2 (Circuit Breakers) and CE Marked.
Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings.

8/2

For Immediate Delivery call KMParts.com at (866) 595-9616

UL / CSA / CE / IEC/EN 60 947

Circuit Breakers/Disconnect/Molded Case Switches


Ratings Overview

Instantaneous Trip Circuit Breakers

Frame Rating

UL/ CSA Interrupting Ratings

kA RMS SYM @

Amps

240 VAC

480 VAC

600 VAC

NZMH 4-...-OBI-CNA

2.1 - 18

NZMH 4-...-OBI-Form CDN

2.1 - 18

NZM 6B-.../ZM 6-...-OBI-CNA

0.6 - 125

NZMH 6-.../ZM 6-...-OBI-CNA

33 - 125

NZM 9-.../ZM 9-...-OBI-CNA

63 - 250

NZMH 9-.../ZM 9-...-OBI-CNA

63 - 250

NZM 10-...N/ZM-...-OBI-NA

400 - 600

NZM 10-...H/ZM-...-OBI-NA

400 - 600

UL Recognized and CSA Certified Instantaneous Trip


circuit breakers no longer carry interrupting ratings as
stand-alone devices.
Per the intent of NEC Article 430-52, an instantaneous
trip circuit breaker shall be used only if part of a listed
combination motor controller. Short circuit ratings are,
therefore, established and valid only for the listed
combination motor controller assembly and associated
housing or enclosure.
Consult Section 3 of this catalog for Combination Motor
Controller short circuit ratings as standard starters
featuring Type NZM Instantaneous Trip Circuit Breakers.
Consult Moeller Electric for Combination Motor Controller high fault short circuit ratings as Motor Control Center
unit starters featuring Type NZM Instantaneous Trip
Circuit Breakers.

Instantaneous Trip Type Circuit Breakers

UL / CSA Short Circuit Ratings

Motor Disconnect Switches


UL 508/CSA 22.2 Nr. 14, IEC/EN 60 947-2, CE
HP rated, with adjustable thermal and magnetic trips
1)

4 - 80

100

25

25

NZM 6B-.../ZM 6-...-CNA

15 - 125

25

25

14

NZMH 6-.../ZM 6-...-CNA

15 - 125

100

65

25

NZM 9-.../ZM 9-...-CNA

63 - 250

30

25

18

NZMH 9-.../ZM 9-...-CNA

63 - 250

200

85

42

NZMH 4-...-CNA

Circuit Breakers
Disconnect Switches, Molded Case Switches

UL 489/CSA 22.2 No. 5.1

Motor Disconnect Switches


UL 508/CSA 22.2 Nr. 14, IEC/EN 60 947-3, CE
HP rated, without trip elements
N6-...-CNA

150

10

10

10

N9-...-CNA

250

10

10

10

N12-...-CNA 2)

1200

42

42

42

NZM 7-...-NA(-M8)

200

25

25

18

NZM 10-...N/B-NA

600

25

25

25

Molded Case Switches


UL 1087, CSA 22.2 Nr. 5.2, IEC/EN 60 947-3, CE
Without trip elements

1) NZMH 4-...-CNA in the range 4 - 16 Amps, UL/CSA only.


2) N12-...-CNA, UL/CSA only.
Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings.

For Immediate Delivery call KMParts.com at (866) 595-9616

8/3

Molded Case Circuit Breakers - Instantaneous Trip


Type NZMH 4-...-OBI...
3

Continuous
Current
Rating

Adjustable
Magnetic Trip
Range

Type

Price

Amps

Amps

Instantaneous Trip Circuit Breakers


Up to 480 V AC, UL/CSA

Circuit Breakers
Disconnect Switches, Molded Case Switches

2.1
3.7
6.6
10
12
15
18

6...12
11...20
18 ...32
28 ...50
42 ...80
64 ...120
100... 200

NZMH 4-2, 1-12-OBI-CNA


NZMH 4-3, 7-20-OBI-CNA
NZMH 4-6, 6-32-OBI-CNA
NZMH 4-10, 50-OBI-CNA
NZMH 4-12, 80-OBI-CNA
NZMH 4-15, 120-OBI-CNA
NZMH 4-18, 200-OBI-CNA

2.1
3.7
6.6
10
12
15
18

6...12
11...20
18 ...32
28 ...50
42 ...80
64 ...120
100... 200

NZMH 4-2, 1-12-OBI-FORM CDN


NZMH 4-3, 7-20-OBI-FORM CDN
NZMH 4-6, 6-32-OBI-FORM CDN
NZMH 4-10, 50-OBI-FORM CDN
NZMH 4-12, 80-OBI-FORM CDN
NZMH 4-15, 120-OBI-FORM CDN
NZMH 4-18, 200-OBI-FORM CDN

NZMH 4-...-OBI-CNA
(18 Amps)

Instantaneous Trip Circuit Breakers


Up to 600Y/347 V AC, CSA Certified only

NZMH 4-...-OBI-Form CDN


(18 Amps)

See Price List See Price List See Price List See Price List See Price List

Frame
Rating

See Price List See Price List See Price List See Price List See Price List

UL/CSA

Type NZMH 4...-OBI... Molded Case Circuit Breakers are UL Recognized (UL 489) and CSA Certified (22.2 Nr. 5.1) Instantaneous Trip type Circuit
Breakers with an adjustable magnetic trip function.
Per NEC, they provide motor short circuit protection as part of a listed combination motor controller that includes coordinated motor overload
protection.
Short circuit interrupting ratings are, therefore, established and valid only for the listed combination motor controller assembly and associated
housing or enclosure.
The NZMH 4 instantaneous trip circuit breaker features a current limiting design contact assembly and can provide high fault short circuit current
ratings of up to 100kA @ 480VAC.
Consult Section 3 of this catalog for Combination Motor Controller short circuit ratings as standard starters featuring Type NZM Instantaneous Trip
Circuit Breakers.
Consult Moeller Electric for Combination Motor Controller high fault short circuit ratings as Motor Control Center unit starters featuring Type NZMH
Instantaneous Trip Circuit Breakers.

Ordering Information:
State type from Column 4. Example: NZMH 4-18-200-OBI-CNA
Note:
- Operating Handle supplied separately. Consult page 8/8 for available handle types.
- Consult page 8/6-11 for additional accessories.
- Line and Load field-wiring terminals for cable connection supplied as standard.

8/4

For Immediate Delivery call KMParts.com at (866) 595-9616

UL/CSA, IEC/EN 60 947-2


5

Motor rating

Type

Price

200 V 230 V 460 V 575 V


HP
HP
HP
HP

NZMH 4-...-CNA Motor Disconnect Switch


46
6 10
10 16
16 25
25 40
40 63
63 80

NZMH 4-...-CNA
(80 Amps)

40 80
60 120
100 200
160 320
260 500
400 800
600 1000

1 1/2
2
3
5
10
20
25

1 1/2
3
5
7 1/2
10
20
30

3
5
10
15
30
40
60

5
7 1/2
10
20
40
60
75

NZMH 4-6-CNA
NZMH 4-10-CNA
NZMH 4-16-CNA
NZMH 4-25-CNA
NZMH 4-40-CNA
NZMH 4-63-CNA
NZMH 4-80-CNA

Type NZMH 4...-CNA Disconnect Switches are UL recognized (UL 508) and CSA certified (22.2 Nr. 14) as 3 pole, HP rated manual motor
disconnects with built-in thermal trips for motor overload protection. An adjustable dial on the front of the switch (refer to column 2) can be set to the
Motor Full Load Current.
They also feature an adjustable magnetic trip to provide additional protection in case of short circuits. In addition they are suitable for group
applications per the intent of NEC 430-53 and CEC part 1, Rule 28-206.
NEC/CEC Group Application ratings:
Maximum Group Fuse or Circuit Breaker
Listed
Branch Circuit
Protective
Fuse

Listed
Branch Circuit
Protective
Breaker

Amps

Amps

600

600

UL/CSA Short Circuit Current Rating


RMS Sym Rating @
240VAC

480VAC

600VAC

100 kA

25 kA

25 kA

Types NZMH 4-25-CNA, NZMH 4-40-CNA, NZMH 4-63-CNA and NZMH 4-80-CNA Disconnect Switches are CE Marked and in Conformity with
IEC/EN 60 947-2 (Circuit Breakers), which makes them suitable internationally as inverse time molded case circuit breakers with adjustable thermal
and magnetic trips. Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings.

Ordering Information:
State type from Column 4. Example: NZMH 4-25-CNA
Note:
- Operating Handle supplied separately. Consult page 8/8 for available handle types.
- Consult page 8/6 - 11 for additional accessories.
- Line and Load field-wiring terminals for cable connection supplied as standard.

For Immediate Delivery call KMParts.com at (866) 595-9616

8/5

Circuit Breakers
Disconnect Switches, Molded Case Switches

Amps

See Price List

Amps

See Price List

Adjustable Adjustable
Thermal
Magnetic Trip
Range
Range
for
motor
overload
protection

See Price List

Frame
Rating

See Price List

Motor Disconnect Switches


Type NZMH 4-...-CNA

Molded Case Circuit Breakers and Disconnect Switches


Auxiliary Contacts and Accessories for NZMH 4...
1

Contacts

Type

Price

Notes

To be ordered with
device only.
Add below suffix.

See Price List

See Price List

See Price List

See Price List

Dots in each row represent the types which can


be combined together. Dashes indicate incompatibility.

+AHI-NZMH 4-NA

See Price List

VHI, AHI and RHI are supplied as


1 N.O. and 1 N.C. contact set but can be field
modified as 2 N.O. or 2 N.C.
contacts.

+RHI-NZMH 4-NA

See Price List

+NHI 22-NZM 4/6-NA

+VHI-NZMH 4-NA

11 15 13 17

Early-Make Auxiliary Contacts


35/37

31/33

36/38

32/34

Handle operated Early-Make Auxiliary Contacts

Circuit Breakers
Disconnect Switches, Molded Case Switches

25/27

21/23

26/28

22/24

Trip Indicating Auxiliary Contacts


45/47

41/43

46/48

42/44

Combination possibilities of
auxiliary contacts:
NHI
VHI
AHI

See Price List

12 16 14 18

See Price List

N.O. N.C.
Standard Auxiliary Contacts

RHI

Type NHI... are standard auxiliary contacts. They operate simultaneously with the main contacts. They can be typically used for signalling or switching auxiliary
circuits such as a control circuit.
Type VHI... are Early Make auxiliary contacts and lead the main contacts when switching ON as well as switching OFF. This makes them ideal for load shedding
purposes or in conjunction with voltage trips in control circuits.
Type AHI... are handle operated Early Make auxiliary contacts. They operate in advance of the main contacts, shortly after the handle has left the OFF position. They
can be typically used to convert the manual actuation of the switch into a control function for circuit interlocking purposes.
Type RHI... are trip indicating auxiliary contacts. They work independently of the normal ON and OFF operations of the device, switching only when the device has
tripped due to overloads, overcurrents or other tripping functions such as voltage trips.
Refer to diagrams below for further details:

NHI

VHI
Same contact position
in both OFF and Tripped
position of the device.

AHI

RHI

Position of auxiliary contacts

Same as main contacts

Main
Contacts:
Closed
Open

L1L2L3

L1L2L3

L1L2L3

L1L2L3

NHI

VHI

AHI

RHI

L1L2L3

L1L2L3

L1L2L3

L1L2L3

NHI

VHI

AHI

RHI

L1L2L3

L1L2L3

L1L2L3

L1L2L3

NHI

VHI

AHI

RHI

Switching ON
I
Switching OFF
I

Tripped position
+
I

Operates only when


Same contact position
in both ON and Tripped device is tripped
(overload, short-circuit,
position of the device.
shunt or undervoltage
trips.)

Ordering Information:
Auxiliary Contacts must be ordered with device. Add type from Column 3. Example: + VHI-NZMH 4-NA.
Note:
Field mounting of contacts is allowed with use of kits. Consult Moeller Electric for information.

8/6

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit Breakers and Disconnect Switches


Voltage Trips for the NZMH 4...
3

Rated
Control
Voltage

Type

Price

Notes

To be ordered with device only.


Add below suffix.

DC

24V

+A-NZM 4/6 (24VDC)

AC
AC
AC
AC
AC

120V 60Hz
208V 60Hz
240V 60Hz
480V 60Hz
600V 60Hz

+U-NZM 4/6 (120V 60Hz)


+U-NZM 4/6 (208V 60Hz)
+U-NZM 4/6 (240V 60Hz)
+U-NZM 4/6 (480V 60Hz)
+U-NZM 4/6 (600V 60Hz)

DC

24V

+U-NZM 4/6 (24VDC)

Undervoltage Trips
Non-delayed

See Price List

52
U <
51

Undervoltage Trips will electrically trip the


device open under power loss and can be
used for control interlocking purposes e.g.
to disconnect the main switch in Emergency-Stop circuits. They are rated for
continuous duty. Power can be applied to
the undervoltage trip using VHI early-make
auxiliary contacts in series with the
undervoltage trip coil.
Undervoltage Trips cannot be mounted
together with Shunt Trips.

Ordering Information:
Voltage trips must be ordered with device. Add type from Column 4. Example: + U-NZM 4/6(480V, 60Hz).

For Immediate Delivery call KMParts.com at (866) 595-9616

8/7

Circuit Breakers
Disconnect Switches, Molded Case Switches

+A-NZM 4/6 (480V 60Hz)


+A-NZM 4/6 (600V 60Hz)

See Price List

480V 60Hz
600V 60Hz

See Price List

AC
AC

Shunt Trips are typically used to electrically trip the device from a remote
location. They are rated for short time duty
only. Short time actuation can be achieved
by using the NHI auxiliary contact ahead in
series with the shunt trip coil.
Shunt Trips cannot be mounted together
with Undervoltage Trips.

See Price List

+A-NZM 4/6 (208V 60Hz)


+A-NZM 4/6 (240V 60Hz)

See Price List

208V 60Hz
240V 60Hz

See Price List

AC
AC

See Price List

+A-NZM 4/6 (120V 60Hz)

See Price List See Price List

120V 60Hz

See Price List

51

AC

See Price List

53

See Price List

Shunt Trips
Short-time duty rating

See Price List See Price List

V/Hz

See Price List

See Price List

Molded Case Circuit Breakers and Disconnect Switches


Accessories for NZMH 4...
1

Color
of
handle

Type
Can be used
with all devices
of Type number

Price

NZMH 4...
NZM(H) 6(B)...

H 6-SW-NA

Red/
Yellow

NZMH 4...
NZM(H) 6(B)...

RH 6-NA

NZMH 4...
NZM(H) 6(B)...

A-NZM 6

NZMH 4...
NZM(H) 6(B)...

SA-NZM 6

NZMH 4...

KV-2 NZM 4

Extension shaft
For mounting depths of 150...400 mm.
Extends shaft length by 266 mm.

Switch position indicator


Indicates position of switch when panel door is open.

Mechanical Interlock
For mechanical interlocking of two devices.
Requires two handles, one for each switch.
Order separately.

Ordering Information:
Specify Type from Column 5. Example: H6-SW-NA
If ordering with device, just add a + in front of the Type number. Example: + H6-SW-NA

8/8

For Immediate Delivery call KMParts.com at (866) 595-9616

See Price List

Black

See Price List

H 6-NA

See Price List

NZMH 4...
NZM(H) 6(B)...

See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

Degree of protection UL/NEMA 3R, 12; IEC IP 55


Door coupling rotary handle. For front mounting in
doors and covers. Can be locked in the OFF position
with up to three padlocks (hasp thickness 6 8 mm).
Door/cover interlocking supplied standard set in OFF
position. Can be field modified for setting in ON position.
3 distinct Handle positions: 0FF - + (tripped) - ON
Red -Yellow version for Emergency-Stop function.

See Price List

Gray

Handle for Cover/Door Interlocking

See Price List

H 4U-SW

See Price List

NZMH 4...

See Price List

Black

See Price List

H 4U

See Price List

NZMH 4...

See Price List

Gray

See Price List

Fastens to shaft, not padlockable

See Price List

Handle for open or panel mounted


devices

See Price List

Molded Case Circuit Breakers and Disconnect Switches


Accessories for NZMH 4...
2

Color
of
handle

Can be used Type


with
To be ordered with
device only. Add
below suffix

Type

Price

NZMH 4...

+ R-NZMH 4

Gray

NZMH 4
NZM(H) 6(B)

H 6-R-NA

Black

NZMH 4
NZM(H) 6(B)

H 6-R-SW-NA

Red/
Yellow

NZMH 4
NZM(H) 6(B)

RH 6-R-NA

ZS60-NZM 6

Main Disconnect Warning plates.


English Inscription:
Main Switch- Open only in OFF position
Silver-colored, black lettering

NZMH 4
NZM(H) 6(B)

ZS62-NZM 6

ZS...-NZM 6

Also available in other languages:


Afrikaans (81)
Finnish (66)
Italian (68)
Russian (74)

Bulgarian (64)
Czech (78)
French (63)
German (61)
Norwegian (70) Polish (71)
Serbo-Croatian (76) Spanish (77)

Danish (65)
Greek (69)
Portuguese (72)
Swedish (75)

Dutch (67)
Hungarian (80)
Romanian (73)
Turkish (79)

Insert key number into Type. Example: ZS 68-NZM 6


(Inscription in Italian language)

See Price List


See Price List
See Price List

See Price List


See Price List
See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

See Price List

NZMH 4
NZM(H) 6(B)

See Price List

Blank (for engraving or printing)

See Price List

ZSSOND-NZM 6

See Price List

See Price List

NZMH 4
NZM(H) 6(B)

See Price List

Specify desired text.


Height of letters: 3.5, 5, and 7 mm

See Price List

Legend Plate (for mounting with operating handle)


Silver-colored, black lettering

See Price List

Operating Handle for rear operation


Used with rear operation shaft.
Degree of protection: UL/NEMA 3R, 12; IEC IP 55
Can be locked in the OFF position with up to
three padlocks (hasp thickness 6 8 mm).
No cover/door interlocking provisions.
3 distinct Handle positions: 0FF - + (tripped) - ON
Red -Yellow version for Emergency-Stop function.

See Price List

Rear operation shafts


For side panel mounting where device is only
accessible from the rear (e.g. sides of enclosure
panels). Must be combined with Type H...R rear
operation handles. Factory installed only.
Order with device.

See Price List

Ordering Information:
Specify Type from Column 5. Example: H6-R-SW-NA.
If ordering with device, just add a + in front of the Type number. Example: + H6-R-SW-NA
Note:
Items in Column 4 are factory installed and must be ordered with the device.

For Immediate Delivery call KMParts.com at (866) 595-9616

8/9

Molded Case Circuit Breakers and Disconnect Switches


Accessories for NZMH 4...
1

Type

Price

Ordering Information:
Specify Type from Column 3. Example: V- NZMH 4
If ordering with device, just add a + in front of the Type number. Example: + V- NZMH 4

8/10

For Immediate Delivery call KMParts.com at (866) 595-9616

See Price List


See Price List
See Price List
See Price List
See Price List

EA-NZM 4-SW

See Price List

Kit includes:
Same as EA-NZMH 4, except that the Main Disconnect handle is
black in color with silver backing plate for standard,
non-Emergency-Stop function.

See Price List

V-NZMH 4-SW

See Price List

Kit includes:
Same as V-NZMH 4, except that the Main Disconnect handle is
black in color with silver backing plate for standard,
non-Emergency-Stop function.

See Price List

See Price List

EA-NZM 4

See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

Kit includes:
Main Disconnect handle for rear operated switches, red in color with
yellow backing plate for Emergency-Stop function, supplied with a
steel plate for panel side-mounting, terminal cover and Main Switch
marking plate

V-NZMH4

See Price List

Kit includes:
Main Disconnect handle with door/cover interlock for front mounting,
red color handle with yellow backing plate for Emergency-Stop function,
terminal cover and Main Switch marking plate.

See Price List

Type NZMH 4... switches with dual UL/CSA and IEC/EN ratings are suitable for use as Main
Disconnect switches in control panels that must be CE marked and designed to comply with
the Machinery Directive standard EN 60 204-1.
The kits shown below, ordered with the device or separately, will provide the necessary
accessories to fulfill the Main Disconnect switch function for these applications.
Note: In cases where the Main Disconnect switch also fulfills the Emergency-Stop function,
please specify kits containing red handle and yellow backing plate assemblies.

See Price List

See Price List

Main Disconnect Switch Assembly Kits for CE marked


control panels per IEC/EN 60 204-1

See Price List

Molded Case Circuit Breakers and Disconnect Switches


Accessories for NZMH 4...
1

Type

Price

Clip
For mounting NZMH 4... devices on a DIN rail. (Rail conforming to the standard
EN 50 022).

C-NZMH 4

See Price List

H-NZMH 4

See Price List

Provides shock hazard protection in the area of the field wiring power terminals. Can be
used at top or bottom, one cover per side.
Mandatory requirement on the supply side of Main Disconnect switches to provide
protection against accidental contact with line side feed.

See Price List

Terminal Cover

See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

Ordering Information:
Specify Type from Column 3. Example: V- NZMH 4
If ordering with device, just add a + in front of the Type number. Example: + V- NZMH 4

For Immediate Delivery call KMParts.com at (866) 595-9616

8/11

Inverse Time Circuit Breakers, 125 Amps


Thermal-Magnetic, Type NZM(H)6(B)...-NA
1

UL/CSA, IEC/EN 60 947-2

Fixed
Thermal
Setting

Adjustable
magnetic trip,
supplied
standard
with the
breaker

Adjustable magnetic trip,


available as a substitute to
standard ratings.
Refer to ordering info
below.

UL/CSA Interrupting
ratings (AC, 60Hz)

Type

Price

RMS Sym Amps @

Amps

65kA

25kA

NZMH 6-63/ZM 6A-15-NA


NZMH 6-63/ZM 6A-20-NA
NZMH 6-63/ZM 6A-25-NA
NZMH 6-63/ZM 6A-30-NA
NZMH 6-63/ZM 6A-35-NA
NZMH 6-63/ZM 6A-40-NA
NZMH 6-63/ZM 6A-50-NA
NZMH 6-63/ZM 6A-60-NA
NZMH 6-100/ZM 6A-70-NA
NZMH 6-100/ZM 6A-80-NA
NZMH 6-100/ZM 6A-90-NA
NZMH 6-100/ZM 6A-100-NA
NZMH 6-160/ZM 6A-125-NA

High Interrupting Rating


NZMH6-.../ZM 6A-...-NA, UL/CSA Current-Limiting circuit breaker

(125A)

15
20
25
30
35
40
50
60
70
80
90
100
125

160 320
160 320
160 320
260 500
260 500
400 800
400 800
400 800
600 1200
600 1200
600 1200
600 1200
600 1200

100 200
100 200
100 200
100 200,
100 200,
160 320,
160 320,
160 320,
260 500,
260 500,
260 500,
260 500,
400 800,

160 320
160 320
260 500
260 500
260 500
400 800
400 800
400 800
400 800
1000 2000

See

100kA

160 320
160 320
260 500
260 500
260 500
400 800
400 800
400 800
400 800
1000 2000

See Price List

NZM 6B-63/ZM 6A-15-NA


NZM 6B-63/ZM 6A-20-NA
NZM 6B-63/ZM 6A-25-NA
NZM 6B-63/ZM 6A-30-NA
NZM 6B-63/ZM 6A-35-NA
NZM 6B-63/ZM 6A-40-NA
NZM 6B-63/ZM 6A-50-NA
NZM 6B-63/ZM 6A-60-NA
NZM 6B-100/ZM 6A-70-NA
NZM 6B-100/ZM 6A-80-NA
NZM 6B-100/ZM 6A-90-NA
NZM 6B-100/ZM 6A-100-NA
NZM 6B-160/ZM 6A-125-NA

See Price List

14kA

See Price List

100 200
100 200
100 200
100 200,
100 200,
160 320,
160 320,
160 320,
260 500,
260 500,
260 500,
260 500,
400 800,

See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

160 320
160 320
160 320
260 500
260 500
400 800
400 800
400 800
600 1200
600 1200
600 1200
600 1200
600 1200

See Price List See Price List See Price List

(125A)

15
20
25
30
35
40
50
60
70
80
90
100
125

See Price List

25kA

NZM 6B-.../ZM 6A-...-NA

See Price List

25kA

Standard Interrupting Rating

See Price List

600 V Standard

See Price List

480 V

See Price List

240 V

See Price List

Amps

See Price List

Amps

Type NZM 6B-.../ZM 6A-...-NA Molded Case Circuit Breakers are UL Listed (UL 489) and CSA Certified (22.2 Nr. 5.1) Inverse Time, thermalmagnetic Circuit Breakers with a fixed thermal and adjustable magnetic trip function.
Type NZMH 6-.../ZM 6A-...-NA Molded Case Circuit Breakers are UL Listed (UL 489) and CSA Certified (22.2 Nr. 5.1) Inverse Time, thermalmagnetic Current Limiting Circuit Breakers with a fixed thermal and adjustable magnetic trip function.
Both types are CE Marked and in Conformity with IEC/EN 60 947-2 (Circuit Breakers), which also makes them suitable internationally as inverse
time molded case circuit breakers. Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings.
Ordering Information:
State type from Column 6. Example: NZM 6B-63/ZM6A-50-NA. (Magnetic Trip range per Column 3).
Optional: Select a substitute magnetic trip range from column 4. Specify it in the Type number by including the number in bold.
Example: NZM 6B-63/ZM6A-50-500-NA
Note:
- Operating Handle supplied separately. Consult page 8/18 for available handle types.
- Consult page 8/16 - 21 for additional accessories.
- Line and Load field-wiring terminals for cable connection supplied as standard.

8/12

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit Breakers- Instantaneous Trip type, 125 Amp


NZM(H)6(B)-.../ZM6-...-OBI...
3

Continuous
Current
Rating

Adjustable
Magnetic Trip
Range

Type

Price

Amps

Amps

Up to 600 V AC, UL/CSA

Standard Interrupting Ratings

33
50
60
80
100
125

100 - 200
260 - 500
400 - 800
260 - 500
600 - 1200
1000 - 2000

NZM 6B-63/ZM 6-33-200-OBI-CNA


NZM 6B-63/ZM 6-50-500-OBI-CNA
NZM 6B-63/ZM 6-60-800-OBI-CNA
NZM 6B-100/ZM 6-80-500-OBI-CNA
NZM 6B-100/ZM 6-100-1200-OBI-CNA
NZM 6B-160/ZM 6-125-2000-OBI-CNA

33
50
60
80
100
125

100 - 200
260 - 500
400 - 800
260 - 500
600 - 1200
1000 - 2000

NZMH 6-63/ZM 6-33-200-OBI-CNA


NZMH 6-63/ZM 6-50-500-OBI-CNA
NZMH 6-63/ZM 6-60-800-OBI-CNA
NZMH 6-100/ZM 6-80-500-OBI-CNA
NZMH 6-100/ZM 6-100-1200-OBI-CNA
NZMH 6-160/ZM 6-125-2000-OBI-CNA

NZM 6B-.../ZM6-...-OBI-CNA
(125 Amps)

High Fault Interrupting Ratings

NZMH6-.../ZM6-...-OBI-CNA
(125 Amps)

Circuit Breakers
Disconnect Switches, Molded Case Switches

Instantaneous Trip Circuit Breakers

See Price List See Price List See Price List See Price List See Price List See Price List

Frame
Rating

See Price List See Price List See Price List See Price List See Price List See Price List

Type NZM6B-.../ZM6-...-OBI... and NZMH6-.../ZM6-...-OBI... Molded Case Circuit Breakers are UL Recognized (UL 489) and
CSA Certified (22.2 Nr. 5.1) Instantaneous Trip type Circuit Breakers with an adjustable magnetic trip function. Per NEC, they provide motor
short circuit protection as part of a listed combination motor controller that includes coordinated motor overload protection.
Short circuit interrupting ratings are, therefore, established and valid only for the listed combination motor controller assembly and associated
housing or enclosure.
The NZMH6 instantaneous trip circuit breaker features a current limiting design contact assembly and can provide high fault short circuit current
ratings of up to 65kA @ 480VAC.
Consult Section 3 of this catalog for Combination Motor Controller short circuit ratings as standard starters featuring Type NZM Instantaneous Trip
Circuit Breakers.
Consult Moeller Electric for Combination Motor Controller high fault short circuit ratings as Motor Control Center unit starters featuring Type NZMH
Instantaneous Trip Circuit Breakers.

Ordering Information:
State type from Column 4. Example: NZM6B-63/ZM6-33-200-OBI-CNA
Note:
- Operating Handle supplied separately. Consult page 8/18 for available handle types.
- Consult page 8/16 - 21 for additional accessories.
- Line and Load field-wiring terminals for cable connection supplied as standard.
- Consult Moeller Electric for Type NZM(H)6(B) Instantaneous Breakers with lower continuous current ratings.

For Immediate Delivery call KMParts.com at (866) 595-9616

8/13

Motor Disconnect Switches


Type NZM(H)6)B)-.../ZM6-...-CNA
4

Adjustable
Thermal
Range
for
motor
overload
protection

Adjustable
Magnetic Trip
Range

Maximum HP Rating
3 Phase @

Type

Price

Amps

Amps

200 V
HP

230 V
HP

460 V
HP

575 V
HP

Standard

5
10
20
30
40

7 1/2
10
20
30
40

15
30
4000
75
100

20
40
60
100
125

NZM 6B-63/ZM 6-25-CNA


NZM 6B-63/ZM 6-40-CNA
NZM 6B-63/ZM 6-63-CNA
NZM 6B-100/ZM 6-100-CNA
NZM 6B-160/ZM 6-125-2000-CNA

5
10
20
30
40

7 1/2
10
20
30
40

15
30
40
75
100

20
40
60
100
125

NZM 6B-63/ZM 6-25-200-CNA


NZM 6B-63/ZM 6-40-320-CNA
NZM 6B-63/ZM 6-63-500-CNA
NZM 6B-100/ZM 6-100-800-CNA
NZM 6B-160/ZM 6-125-CNA

5
10
20
30
40

7 1/2
10
20
30
40

15
30
40
75
100

20
40
60
100
125

NZMH 6-63/ZM 6-25-CNA


NZMH 6-63/ZM 6-40-CNA
NZMH 6-63/ZM 6-63-CNA
NZMH 6-100/ZM 6-100-CNA
NZMH 6-160/ZM 6-125-2000-CNA

5
10
20
30
40

7 1/2
10
20
30
40

15
30
40
75
100

20
40
60
100
125

NZMH 6-63/ZM 6-25-200-CNA


NZMH 6-63/ZM 6-40-320-CNA
NZMH 6-63/ZM 6-63-500-CNA
NZMH6-100/ZM 6-100-800-CNA
NZMH 6-160/ZM 6-125-CNA

High Fault Short Circuit Ratings


NZMH6-.../ZM6-...-CNA
15 - 25
25 - 40
40 - 63
63 - 100
100 - 125

160 320
260 500
400 800
600 1200
1000 2000

See Price List

100 200
160 320
260 500
400 800
600 1200

See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

15 - 25
25 - 40
40 - 63
63 - 100
100 - 125

See Price List

with optional lower magnetic trip values:


(125 Amps)

See Price List

160 320
260 500
400 800
600 1200
1000 2000

See Price List

NZM 6B-.../ZM6-...-CNA
15 - 25
25 - 40
40 - 63
63 - 100
100 - 125

See Price List

Standard Short Circuit Ratings

See Price List

See Price List

See Price List

Frame
Rating

See Price List

UL/CSA, IEC/EN 60 947-2

with optional lower magnetic trip values:


(125 Amps)

15 - 25
25 - 40
40 - 63
63 - 100
100 - 125

100 200
160 320
260 500
400 800
600 1200

Types NZM6B-.../ZM6-...-CNA and NZMH6-.../ZM6-...-CNA Disconnect Switches are UL recognized (UL 508) and CSA certified (22.2 Nr. 14) as 3 pole, HP rated
manual motor disconnects with built-in thermal trips for motor overload protection. An adjustable dial on the front of the switch (refer to column 2) can be set to the
Motor Full Load Current.
They also feature an adjustable magnetic trip to provide additional protection in case of short circuits. Per NEC, Branch Circuit Overcurrent protection devices must
be provided separately.

Type

UL/CSA Short Circuit Current Rating


RMS Sym Rating @
240VAC
480VAC
600VAC

NZM6B-.../ZM6-...-CNA
NZMH6-.../ZM6-...-CNA

25 kA
100 kA

25 kA
65 kA

14 kA
25 kA

Types NZM6B-.../ZM6-...-CNA and NZMH6-.../ZM6-...-CNA Disconnect Switches are CE Marked and in Conformity with IEC/EN 60 947-2 (Circuit Breakers), which
makes them suitable internationally as inverse time molded case circuit breakers with adjustable thermal and magnetic trips.
Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings.

Ordering Information:
State type from Column 5. Example: NZM6B-63/ZM6-40-CNA
Note:
- Operating Handle supplied separately. Consult page 8/18 for available handle types.
- Consult page 8/16 - 21 for additional accessories.
- Line and Load field-wiring terminals for cable connection supplied as standard.

8/14

For Immediate Delivery call KMParts.com at (866) 595-9616

Continuous
Current
Rating

Maximum HP Rating
3 Phase @

Type

Price

Amps

200 V
HP

575 V
HP

20
30

25
40

50
75

60
100

40

60

100

125

Motor Disconnect Switches N6-...-CNA


63
100
150

N 6-63-CNA
N 6-100-CNA
N 6-160-CNA

(150 Amps)

See Price List

460 V
HP

See Price List

230 V
HP

See Price List

Frame
Rating

See Price List

Motor Disconnect Switches, 150 Amps


Type N6-...-CNA

Type N6...-CNA Disconnect Switches are UL recognized (UL 508) and CSA certified (22.2 Nr. 14) as 3 pole, HP rated non-automatic manual motor
disconnects without any overload or short circuit tripping elements. Their switching mechanism has 3 positions (OFF, ON, + Tripped) and they can
be equipped with voltage trip accessories such as shunt trip and undervoltage trip coils.
UL/CSA Short Circuit Rating @ 600VAC: 10 kA RMS Sym.
N6...-CNA Disconnect Switches are also CE Marked and in Conformity with IEC/EN 60 947-3 (Switch-Disconnectors), which makes them suitable
internationally as Main Disconnect switches in a broad range of industrial applications.
Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings.

Circuit Breakers
Disconnect Switches, Molded Case Switches

UL/CSA, IEC/EN 60 947-3

Ordering Information:
State type from Column 5. Example: N 6-100-CNA
Note:
- For direct-on-line switching of motors, use in combination with a listed magnetic contactor.
- Operating Handle supplied separately. Consult page 8/18 for available handle types.
- Consult page 8/16 21 for additional accessories.
- Line and Load field-wiring terminals for cable connection supplied as standard.

For Immediate Delivery call KMParts.com at (866) 595-9616

8/15

Molded Case Circuit Breakers and Disconnect Switches


Auxiliary Contacts for NZM(H)6(B)...
2

Contacts

Type

Price

Notes

+NHI 22-NZM 4/6-NA

2 Form C
(Change over)
Contacts

+VHI 002-NZM 6-NA

11 15 13 17

Early-Make Auxiliary Contacts


32 34 36 38

31

35

See Price List

25

+AHI 002-NZM 6-NA

+RHI 002-NZM 6-NA

See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

21

2 Form C
(Change over)
Contacts

See Price List

22 24 26 28

See Price List

Handle operated Early-Make Auxiliary Contacts

Trip Indicating Auxiliary Contacts


42 44 46 48

41

45

2 Form C
(Change over)
Contacts

See Price List

12 16 14 18

See Price List

N.O. N.C.
Standard Auxiliary Contacts

See Price List

To be ordered with
device only.
Add below suffix.

See Price List

Combination possibilities of
auxiliary contacts:
NHI
VHI
AHI

RHI

Dots in each row represent the types which can


be combined together. Dashes indicate incompatibility.

Type NHI... are standard auxiliary contacts. They operate simultaneously with the main contacts. They can be typically used for signalling or switching auxiliary
circuits such as a control circuit.
Type VHI... are Early Make auxiliary contacts and lead the main contacts when switching ON as well as switching OFF. This makes them ideal for load shedding
purposes or in conjunction with voltage trips in control circuits.
Type AHI... are handle operated Early Make auxiliary contacts. They operate in advance of the main contacts, shortly after the handle has left the OFF position. They
can be typically used to convert the manual actuation of the switch into a control function for circuit interlocking purposes.
Type RHI... are trip indicating auxiliary contacts. They work independently of the normal ON and OFF operations of the device, switching only when the device has
tripped due to overloads, overcurrents or other tripping functions such as voltage trips.
Refer to diagrams below for further details:

NHI

VHI
Same contact position
in both OFF and Tripped
position of the device.

AHI
Same contact position
in both ON and Tripped
position of the device.

RHI
Operates only when
device is tripped
(overload, short-circuit,
shunt or undervoltage
trips.)

Position of auxiliary contacts

Same as main contacts

Main
Contacts:
Closed
Open

L1L2L3

L1L2L3

L1L2L3

L1L2L3

NHI

VHI

AHI

RHI

L1L2L3

L1L2L3

L1L2L3

L1L2L3

NHI

VHI

AHI

RHI

L1L2L3

L1L2L3

L1L2L3

L1L2L3

NHI

VHI

AHI

RHI

Switching ON
I
Switching OFF
I

Tripped position
+
I

VHI and AHI-NZM 6 operate in similar fashion during switching ON and OFF.

Ordering Information:
Auxiliary Contacts must be ordered with device. Add type from Column 3. Example: + VHI 002-NZM 6-NA.

8/16

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit Breakers and Disconnect Switches


Voltage Trips for NZM(H)6(B)...
6

Price

Notes

V/Hz

To be ordered with device only.


Add below suffix.

AC

120V 60Hz

+A-NZM 4/6 (120V 60Hz)

AC

208V 60Hz

+A-NZM 4/6 (208V 60Hz)

AC

240V 60Hz

+A-NZM 4/6 (240V 60Hz)

AC

480V 60Hz

+A-NZM 4/6 (480V 60Hz)

AC

600V 60Hz

+A-NZM 4/6 (600V 60Hz)

DC

24V

+A-NZM 4/6 (24VDC)

AC

120V 60Hz

+U-NZM 4/6 (120V 60Hz)

AC

208V 60Hz

+U-NZM 4/6 (208V 60Hz)

AC

240V 60Hz

+U-NZM 4/6 (240V 60Hz)

AC

480V 60Hz

+U-NZM 4/6 (480V 60Hz)

AC

600V 60Hz

+U-NZM 4/6 (600V 60Hz)

DC

24V

+U-NZM 4/6 (24VDC)

52
U <
51

See Price List

Shunt Trips are typically used to electrically trip


the device from a remote location. They are
rated for short time duty only. Short time
actuation can be achieved by using the NHI
auxiliary contact ahead in series with the shunt
trip coil.
Shunt Trips cannot be mounted together with
Undervoltage Trips.

Undervoltage Trips will electrically trip the


device open under power loss and can be used
for control interlocking purposes e.g. to
disconnect the main switch in Emergency-Stop
circuits. They are rated for continuous duty.
Power can be applied to the undervoltage trip
using VHI early-make auxiliary contacts in
series with the undervoltage trip coil.
Undervoltage Trips cannot be mounted
together with Shunt Trips.

Ordering Information:
Voltage trips must be ordered with device. Add type from Column 4. Example: + U-NZM 4/6(480V, 60Hz).

For Immediate Delivery call KMParts.com at (866) 595-9616

Circuit Breakers
Disconnect Switches, Molded Case Switches

Continuous duty rating

See Price List

Undervoltage Trips

See Price List

51

See Price List

53

See Price List

Short-time duty rating

See Price List

Shunt Trips

See Price List

Rated
Control
Voltage

See Price List

Type

See Price List

See Price List

See Price List

See Price List

8/17

Molded Case Circuit Breakers and Disconnect Switches


Accessories for NZM(H)6(B)...
1

Color
of
handle

Can be used
Type
with all devices
of Type number

Price

Red/
Yellow

NZMH 4
NZM(H) 6(B)
N6....

RH 6-NA

NZMH 4
NZM(H) 6(B)
N6....

A-NZM 6

NZM(H) 6(B)
N6....

SVB-NZM 6

NZMH 4
NZM(H) 6(B)
N6....

SA-NZM 6

NZM(H) 6(B)
N6....

H6UZ

NZM(H) 6(B)
N6....

KV-2 NZM 6

Extension shaft
For mounting depths of 150 400 mm.
Extends shaft length by 266 mm. Only one
extension shaft possible. Can also be used
with the mechanical interlock.

Padlocking accessory
Enables the device to be padlocked OFF when the panel
door is open. Accommodates up to 3 padlocks (hasp
size 1/4, 6 8mm).
A limit switch (Type AT0) can also be installed for signalling
or electrical interlocking purposes.

Switch position indicator


Indicates position of switch when panel door is open.

Maintenance Handle
To actuate the device when the panel door is open.

Mechanical Interlock
For mechanical interlocking of two devices.
Requires two handles, one for each switch.
Order separately.

Ordering Information:
Specify Type from Column 5. Example: H6-SW-NA
If ordering with device, just add a + in front of the Type number. Example: + H6-SW-NA

8/18

For Immediate Delivery call KMParts.com at (866) 595-9616

See Price List

H 6-SW-NA

See Price List

NZMH 4
NZM(H) 6(B)
N6....

See Price List

Black

See Price List

H 6-NA

See Price List

NZMH 4
NZM(H) 6(B)
N6....

See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

Degree of protection UL/NEMA 3R, 12; IEC IP 55


Door coupling rotary handle. For front mounting in
doors and covers. Can be locked in the OFF position
with up to three padlocks (hasp thickness 6 8 mm).
Door/cover interlocking supplied standard set in
OFF position. Can be field modified for setting in
ON position.
3 distinct Handle positions: 0FF - + (tripped) - ON
Red -Yellow version for Emergency-Stop function.

See Price List

Gray

Handle for Cover/Door Interlocking

See Price List

H 6U-SW

See Price List

NZM(H)6(B)...
N6....

See Price List

Black

See Price List

H 6U

See Price List

NZM(H)6(B)...
N6....

See Price List

Gray

See Price List

Fastens to shaft, not padlockable

See Price List

Handle for open or panel mounted devices

See Price List

Molded Case Circuit Breakers and Disconnect Switches


Accessories for NZM(H)6(B)...
2

Color
of
handle

Can be used
with

Type

Type

Price

RH 6-R-NA

Legend Plate (for mounting with operating handle)


Silver-colored, black lettering

Specify desired text.


Height of letters: 3.5, 5, and 7 mm

NZMH 4
NZM(H) 6(B)
N6...

ZSSOND-NZM 6

Blank (for engraving or printing)

NZMH 4
NZM(H) 6(B)
N6...

ZS60-NZM 6

Main Disconnect Warning plates.


English Inscription:
Main Switch- Open only in OFF position
Silver-colored, black lettering

NZMH 4
NZM(H) 6(B)
N6...

ZS62-NZM 6

Also available in other languages:

NZMH 4
NZM(H) 6(B)
N6...

ZS...-NZM 6

Afrikaans (81)
Finnish (66)
Italian (68)
Russian (74)

Bulgarian (64)
Czech (78)
French (63)
German (61)
Norwegian (70) Polish (71)
Serbo-Croatian (76) Spanish (77)

Danish (65)
Greek (69)
Portuguese (72)
Swedish (75)

Dutch (67)
Hungarian (80)
Romanian (73)
Turkish (79)

Insert key number into Type. Example: ZS61-NZM 6


(Inscription in German language)

Circuit Breakers
Disconnect Switches, Molded Case Switches

See Price List

NZMH 4
NZM(H) 6(B)
N6...

See Price List

Red/
Yellow

See Price List

H 6-R-SW-NA

See Price List

See Price List

NZMH 4
NZM(H) 6(B)
N6...

See Price List

Black

See Price List

H 6-R-NA

See Price List

See Price List

NZMH 4
NZM(H) 6(B)
N6...

See Price List

Gray

See Price List

See Price List

+ R-NZMH 6

See Price List

NZM(H) 6(B)...
N6...

See Price List

Operating Handle for rear operation


Used with rear operation shaft.
Degree of protection: UL/NEMA 3R, 12; IEC IP 55
Can be locked in the OFF position with up to
three padlocks (hasp thickness 6 8 mm).
No cover/door interlocking provisions.
3 distinct Handle positions: 0FF - + (tripped) - ON
Red -Yellow version for Emergency-Stop function.

See Price List

Rear operation shafts


For side panel mounting where device is only
accessible from the rear (e.g. sides of enclosure
panels). Must be combined with Type H...R-NA rear
operation handles. Factory installed only.
Order with device.

To be ordered with
device only. Add
below suffix

See Price List

Ordering Information:
Specify Type from Column 5. Example: H6-R-SW-NA.
If ordering with device, just add a + in front of the Type number. Example: + H6-R-SW-NA
Note:
Items in Column 4 are factory installed and must be ordered with the device.

For Immediate Delivery call KMParts.com at (866) 595-9616

8/19

Molded Case Circuit Breakers and Disconnect Switches


Accessories for NZM(H)6(B)...
3

Type

Price

EA-NZM 6

Kit includes:
Same as V-NZM 6, except that the Main Disconnect handle is
black in color with silver backing plate for standard,
non-Emergency-Stop function.

V-NZM 6-SW

Kit includes:
Same as EA-NZM 6, except that the Main Disconnect handle is
black in color with silver backing plate for standard,
non-Emergency-Stop function.

EA-NZM 6-SW

Ordering Information:
Specify Type from Column 3. Example: V- NZM 6
If ordering with device, just add a + in front of the Type number. Example: + V- NZM 6

8/20

For Immediate Delivery call KMParts.com at (866) 595-9616

See Price List


See Price List
See Price List See Price List

Kit includes:
Main Disconnect handle for rear operated switches, red in color with
yellow backing plate for Emergency-Stop function, supplied with a
steel plate for panel side-mounting, terminal cover and Main Switch
marking plate

See Price List

V-NZM 6

See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

Kit includes:
Main Disconnect handle with door/cover interlock for front mounting,
red color handle with yellow backing plate for Emergency-Stop function,
terminal cover and Main Switch marking plate.

See Price List

Type NZM(H)6(B)-... switches with dual UL/CSA and IEC/EN ratings are suitable for use as
Main Disconnect switches in control panels that must be CE marked and designed to comply
with the Machinery Directive standard EN 60 204-1.
The kits shown below, ordered with the device or separately, will provide the necessary
accessories to fulfill the Main Disconnect switch function for these applications.
Note: In cases where the Main Disconnect switch also fulfills the Emergency-Stop function,
please specify kits containing red handle and yellow backing plate assemblies.

See Price List

Main Disconnect Switch Assembly Kits for CE marked


control panels per IEC/EN 60 204-1

See Price List

When ordered
separately
without device

See Price List

See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List

Molded Case Circuit Breakers and Disconnect Switches


Accessories for NZM(H)6(B)...
2

Type

Type

Price

To be ordered with
device only. Add
suffix shown below

See Price List


See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

See Price List


See Price List

H-NZM 6

See Price List

See Price List

Provides shock hazard protection in the area of the field wiring


power terminals. Can be used at top or bottom, one cover per side.
Mandatory requirement on the supply side of Main Disconnect
switches to provide protection against accidental contact with line
side feed.

See Price List

Terminal Cover

+ST-NA

See Price List

Supplementary terminals attached to main terminals.


3 connections top and bottom. Factory addition only, must be
ordered with device.

See Price List

Control Circuit Tap-Off Terminals

See Price List

Ordering Information:
Accessory in Column 2 can only be ordered with device. Specify Type suffix. Example: + ST-NA
Specify Type from Column 3. Example: H-NZM 6
If ordering with device, just add a + in front of the Type number. Example: + H-NZM 6

For Immediate Delivery call KMParts.com at (866) 595-9616

8/21

Inverse Time Circuit Breakers, 250 Amps


Thermal-Magnetic, Type NZM(H)9...-NA
6

Type

Price

480 V

600 V Standard

400 800
400 800
400 800
600 1200,
600 1200,
600 1200
600 1200,
600 1200,
600 1200,
600 1200,

30 kA

25 kA

18 kA NZM 9-250/ZM 9A-70-NA


NZM 9-250/ZM 9A-80-NA
NZM 9-250/ZM 9A-90-NA
NZM 9-250/ZM 9A-100-NA
NZM 9-250/ZM 9A-125-NA
NZM 9-250/ZM 9A-150-NA
NZM 9-250/ZM 9A-175-NA
NZM 9-250/ZM 9A-200-NA
NZM 9-250/ZM 9A-225-NA
NZM 9-250/ZM 9A-250-NA

Standard Interrupting Rating


NZM 9-.../ZM 9A-...-NA

(250A)

Circuit Breakers
Disconnect Switches, Molded Case Switches

70
80
90
100
125
150
175
200
225
250

600 1200
600 1200
600 1200
1000 2000
1000 2000
1000 2000
1600 2400
1600 2400
1600 2400
1600 2400

400 800
400 800
1000 2000
1000 2000
1000 2000
1000 2000

High Interrupting Rating


NZMH9-.../ZM 9A-...-NA, UL/CSA Current-Limiting circuit breaker

(250A)

70
80
90
100
125
150
175
200
225
250

600 1200
600 1200
600 1200
1000 2000
1000 2000
1000 2000
1600 2400
1600 2400
1600 2400
1600 2400

400 800
400 800
400 800
600 1200,
600 1200,
600 1200
600 1200,
600 1200,
600 1200,
600 1200,

200 kA 85 kA

400 800
400 800
1000 2000
1000 2000
1000 2000
1000 2000

42 kA NZMH 9-250/ZM 9A-70-NA


NZMH 9-250/ZM 9A-80-NA
NZMH 9-250/ZM 9A-90-NA
NZMH 9-250/ZM 9A-100-NA
NZMH 9-250/ZM 9A-125-NA
NZMH 9-250/ZM 9A-150-NA
NZMH 9-250/ZM 9A-175-NA
NZMH 9-250/ZM 9A-200-NA
NZMH 9-250/ZM 9A-225-NA
NZMH 9-250/ZM 9A-250-NA

$
See Price List

240 V

See Price List

Amps

See Price List

Amps

See Price List

Amps

See Price List

Adjustable magnetic trip,


UL/CSA Interrupting
available as a substitute to ratings (AC, 60 Hz)
standard ratings.
Refer to ordering info
RMS Sym Amps @
below.

See Price List

Adjustable
magnetic trip,
supplied
standard
with the
breaker

See Price List

Fixed
Thermal
Setting

See Price List

See Price List

See Price List

See Price List

See Price List

UL/CSA, IEC/EN 60 947-2

Type NZM 9-.../ZM 9A-...-NA Molded Case Circuit Breakers are UL Listed (UL 489) and CSA Certified (22.2 Nr. 5.1) Inverse Time, thermal-magnetic
Circuit Breakers with a fixed thermal and adjustable magnetic trip function.
Type NZMH 9-.../ZM 9A-...-NA Molded Case Circuit Breakers are UL Listed (UL 489) and CSA Certified (22.2 Nr. 5.1) Inverse Time,
thermal-magnetic Current Limiting Circuit Breakers with a fixed thermal and adjustable magnetic trip function.
Both types are CE Marked and in Conformity with IEC/EN 60 947-2 (Circuit Breakers), which also makes them suitable internationally as inverse
time molded case circuit breakers.
Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings.

Ordering Information:
State type from Column 6. Example: NZM 9-250/ZM9A-250-NA (Magnetic Trip range per Column 3).
Optional: Select a substitute magnetic trip range from column 4. Specify it in the Type number by including the number in bold.
Example: NZM 9-250/ZM9A-250-2000-NA
Note:
- Operating Handle supplied separately. Consult page 8/28 for available handle types.
- Consult page 8/26 - 31 for additional accessories.
- Line and Load field-wiring terminals for cable connection supplied as standard.

8/22

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit Breakers- Instantaneous Trip type, 250 Amp


Type NZM(H)9-.../ZM9-...-OBI...
2

Continuous
Current
Rating

Adjustable
Magnetic Trip
Range

Type

Price

Amps

Amps

400 800
600 1200
1000 2000
1600 2400
1600 2400

NZM 9-250/ZM 9-63-800-OBI-CNA


NZM 9-250/ZM 9-100-1200-OBI-CNA
NZM 9-250/ZM 9-160-2000-OBI-CNA
NZM 9-250/ZM 9-200-2400-OBI-CNA
NZM 9-250/ZM 9-250-2400-OBI-CNA

63
100
160
200
250

400 800
600 1200
1000 2000
1600 2400
1600 2400

NZMH 9-250/ZM 9-63-800-OBI-CNA


NZMH 9-250/ZM 9-100-1200-OBI-CNA
NZMH 9-250/ZM 9-160-2000-OBI-CNA
NZMH 9-250/ZM 9-200-2400-OBI-CNA
NZMH 9-250/ZM 9-250-2400-OBI-CNA

See Price List

NZMH 9-.../ZM9-...-OBI-CNA
(250 Amps)

See Price List

High Fault Interrupting Ratings

See Price List

NZM 9-.../ZM9-...-OBI-CNA
(250 Amps)

See Price List

See Price List

63
100
160
200
250

Circuit Breakers
Disconnect Switches, Molded Case Switches

Standard Interrupting Ratings

See Price List

Up to 600 V AC, UL/CSA

See Price List

Instantaneous Trip Circuit Breakers

See Price List

$
See Price List

Frame
Rating

See Price List

Type NZM9-.../ZM9-...-OBI... and NZMH9-.../ZM9-...-OBI... Molded Case Circuit Breakers are UL Recognized (UL 489) and
CSA Certified (22.2 Nr. 5.1) Instantaneous Trip type Circuit Breakers with an adjustable magnetic trip function.
Per NEC, they provide motor short circuit protection as part of a listed combination motor controller that includes coordinated motor overload
protection. Short circuit interrupting ratings are, therefore, established and valid only for the listed combination motor controller assembly and
associated housing or enclosure.
The NZMH 9 instantaneous trip circuit breaker features a current limiting design contact assembly and can provide high fault short circuit current
ratings of up to 85 kA @ 480 V AC.
Consult Section 3 of this catalog for Combination Motor Controller short circuit ratings as standard starters featuring Type NZM... Instantaneous Trip
Circuit Breakers.
Consult Moeller Electric for Combination Motor Controller high fault short circuit ratings as Motor Control Center unit starters featuring Type NZMH...
Instantaneous Trip Circuit Breakers.

Ordering Information:
State type from Column 4. Example: NZM 9-250/ZM9-250-2400-OBI-CNA
Note:
- Operating Handle supplied separately. Consult page 8/28 for available handle types.
- Consult page 8/ 26 - 31 for additional accessories.
- Line and Load field-wiring terminals for cable connection supplied as standard.

For Immediate Delivery call KMParts.com at (866) 595-9616

8/23

Motor Disconnect Switches


Type NZM(H)9-.../ZM9-...-CNA
4

Adjustable
Thermal
Range
for
motor
overload
protection

Adjustable
Magnetic Trip
Range

Maximum HP Rating
3 Phase @

Type

Price

Amps

Amps

200 V
HP

230 V
HP

460 V
HP

575 V
HP

Standard

30
50
60
75

30
60
75
75

75
125
150
150

100
150
200
225

NZM 9-250/ZM 9-100-CNA


NZM 9-250/ZM 9-160-CNA
NZM 9-250/ZM 9-200-CNA
NZM 9-250/ZM 9-250-CNA

30
60
75
75

75
125
150
150

100
150
200
225

NZM 9-250/ZM 9-100-800-CNA


NZM 9-250/ZM 9-160-1200-CNA
NZM 9-250/ZM 9-200-2000-CNA
NZM 9-250/ZM 9-250-2000-CNA

30
60
75
75

75
125
150
150

100
150
200
225

NZMH 9-250/ZM 9-100-CNA


NZMH 9-250/ZM 9-160-CNA
NZMH 9-250/ZM 9-200-CNA
NZMH 9-250/ZM 9-250-CNA

30
60
75
75

75
125
150
150

100
150
200
225

NZMH 9-250/ZM 9-100-800-CNA


NZMH 9-250/ZM 9-160-1200-CNA
NZMH 9-250/ZM 9-200-2000-CNA
NZMH 9-250/ZM 9-250-2000-CNA

High Fault Short Circuit Ratings


NZMH 9-.../ZM 9-...-CNA
63 100
100 160
160 200
200 250

600 1200
1000 2000
1600 2400
1600 2400

30
50
60
75

with optional lower magnetic trip values:


(250A)

63 100
100 160
160 200
200 250

400 800
600 1200
1000 2000
1000 2000

30
50
60
75

See Price List


See Price List

with optional lower magnetic trip values:


63 100
400 800
30
100 160
600 1200
50
160 200
60
1000 2000
200 250
75
1000 2000

See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

(250A)

600 1200
1000 2000
1600 2400
1600 2400

See Price List

63 100
100 160
160 200
200 250

See Price List

NZM 9-.../ZM 9-...-CNA

See Price List

Standard Short Circuit Ratings

See Price List

See Price List

See Price List

Frame
Rating

See Price List

UL/CSA, IEC/EN 60 947-2

Types NZM 9-.../ZM 9-...-CNA and NZMH 9-.../ZM 9-...-CNA Disconnect Switches are UL recognized (UL 508) and CSA certified (22.2 Nr. 14) as
3-pole, HP rated manual motor disconnects with built-in thermal trips for motor overload protection. An adjustable dial on the front of the switch
(refer to column 2) can be set to the Motor Full Load Current.
They also feature an adjustable magnetic trip to provide additional protection in case of short circuits. Per NEC, Branch Circuit Overcurrent protection devices must be provided separately.
Type

UL/CSA Short Circuit Current Rating


RMS Sym Rating @
240 V AC
480 V AC
600 V AC

NZM 9-.../ZM9-...-CNA
NZMH 9-.../ZM9-...-CNA

30 kA
200 kA

25 kA
85 kA

18 kA
42 kA

Types NZM 9-.../ZM 9-...-CNA and NZMH 9-.../ZM 9-...-CNA Disconnect Switches are CE Marked and in Conformity with IEC/EN 60 947-2 (Circuit
Breakers), which makes them suitable internationally as inverse time molded case circuit breakers with adjustable thermal and magnetic trips.
Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings.

Ordering Information:
State type from Column 5. Example: NZM 9-250/ZM 9-200-CNA
Note:
- For direct-on-line switching of motors, use in combination with a listed magnetic contactor.
- Operating Handle supplied separately. Consult page 8/28 for available handle types.
- Consult page 8/ 26 - 31 for additional accessories.
- Line and Load field-wiring terminals for cable connection supplied as standard.

8/24

For Immediate Delivery call KMParts.com at (866) 595-9616

Continuous
Current
Rating

Maximum HP Rating
3 Phase @

Type

Price

Amps

200 V 230 V
HP
HP

460 V
HP

575 V
HP

60

150

200

N9-...-CNA Motor Disconnect Switches


250

75

N 9-250-CNA

(250A)

See Price List See Price List

Frame
Rating

See Price List See Price List

Motor Disconnect Switches, 250 Amps


Type N9-...-CNA

Type N9...-CNA Disconnect Switches are UL recognized (UL 508) and CSA certified (22.2 Nr. 14) as 3 pole, HP rated nonautomatic manual motor
disconnects without any overload or short circuit tripping elements.
Their switching mechanism has 3 positions (OFF, ON, + Tripped) and they can be equipped with voltage trip accessories such as shunt trip and
undervoltage trip coils.
UL/CSA Short Circuit Rating @ 600 V AC: 10 kA RMS Sym.
N9...-CNA Disconnect Switches are also CE Marked and in Conformity with IEC/EN 60 947-3 (Switch-Disconnectors), which makes them suitable
internationally as Main Disconnect switches in a broad range of industrial applications.
Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings.

Circuit Breakers
Disconnect Switches, Molded Case Switches

UL/CSA, IEC/EN 60 947-3

Ordering Information:
State type from Column 5: N 9-250-CNA
Note:
- For direct-on-line switching of motors, use in combination with a listed magnetic contactor.
- Operating Handle supplied separately. Consult page 8/28 for available handle types.
- Consult page 8/ 26 - 31 for additional accessories.
- Line and Load field-wiring terminals for cable connection supplied as standard.

For Immediate Delivery call KMParts.com at (866) 595-9616

8/25

Accessories for NZM(H) 9... Molded Case Circuit Breakers and Disconnect Switches
Auxiliary Contacts

N.C.

Type

Price

Notes

To be ordered with
device only.
Add below suffix.
$

Standard Auxiliary Contacts


2

12 16 14 18

+NHI 22-NZM 9

11 15 13 17

Early-Make Auxiliary Contacts


2 Form C
+VHI 002-NZM 9
(Changeover)
Contacts

32 34 36 38

31

35

See Price List

25

2 Form C
+RHI 002-NZM 9
(Changeover)
Contacts

See Price List

21

2 Form C
+AHI 002-NZM 9
(Changeover)
Contacts

See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

22 24 26 28

See Price List

Handle operated Early-Make Auxiliary Contacts

Trip Indicating Auxiliary Contacts


42 44 46 48

41

45

See Price List

N.O.

See Price List

Contacts

See Price List

See Price List

Combination possibilities of
auxiliary contacts:
NHI
VHI
AHI
l
l

l
l

RHI

Dots in each row represent the types which can


be combined together. Dashes indicate incompatibility.

Type NHI... are standard auxiliary contacts. They operate simultaneously with the main contacts. They can be typically used for signalling or
switching auxiliary circuits such as a control circuit.
Type VHI... are Early Make auxiliary contacts and lead the main contacts when switching ON as well as switching OFF. This makes them ideal for
load shedding purposes or in conjunction with voltage trips in control circuits.
Type AHI... are handle operated Early Make auxiliary contacts. They operate in advance of the main contacts, shortly after the handle has left the
OFF position. They can be typically used to convert the manual actuation of the switch into a control function for circuit interlocking purposes.
Type RHI... are trip indicating auxiliary contacts. They work independently of the normal ON and OFF operations of the device, switching only when
the device has tripped due to overloads, overcurrents or other tripping functions such as voltage trips.
Refer to diagrams below for further details:

NHI
Same as main contacts

Position of auxiliary contacts


Main
Contacts:
Closed
Open

VHI
Same contact position
in both OFF and Tripped
position of the device.

Switching ON
I
Switching OFF
I

Tripped position
+
I

AHI
RHI
Operates only when
Same contact position
in both ON and Tripped device is tripped
(overload, short-circuit,
position of the device.
shunt or undervoltage
trips.)

L1L2L3

L1L2L3

L1L2L3

L1L2L3

NHI

VHI

AHI

RHI

L1L2L3

L1L2L3

L1L2L3

L1L2L3

NHI

VHI

AHI

RHI

L1L2L3

L1L2L3

L1L2L3

L1L2L3

NHI

VHI

AHI

RHI

Ordering Information:
Auxiliary Contacts must be ordered with device. Add type from Column 3.
Example: + VHI 002-NZM 9.

8/26

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit Breakers and Disconnect Switches


Voltage Trips for NZM(H) 9...
3

Rated
Control
Voltage

Type

Price

Notes

To be ordered with device only.


Add below suffix.

24 V

+A-NZM 9 (24V DC)

AC
AC
AC
AC
AC

120 V 60 Hz
208 V 60 Hz
240 V 60 Hz
480 V 60 Hz
600 V 60 Hz

+U-NZM 9 (120V 60Hz)


+U-NZM 9 (208V 60Hz)
+U-NZM 9 (240V 60Hz)
+U-NZM 9 (480V 60Hz)
+U-NZM 9 (600V 60Hz)

DC

24 V

+U-NZM 9 (24VDC)

Undervoltage Trips
52
U <
51

Shunt Trips are typically used to electrically


trip the device from a remote location.
The A-NZM 9... series is rated for 100%
continuous duty. If desired, automatic
disconnection of the shunt trip coil can be
achieved by using the NHI auxiliary contact in
series with the coil.
Shunt Trips cannot be mounted together with
Undervoltage Trips.

Undervoltage Trips will electrically trip the


device open under power loss and can be
used for control interlocking purposes e.g. to
disconnect the main switch in EmergencyStop circuits. They are rated for continuous
duty. Power can be applied to the
undervoltage trip using VHI early-make
auxiliary contacts in series with the
undervoltage trip coil.
Undervoltage Trips cannot be mounted
together with Shunt Trips.

Circuit Breakers
Disconnect Switches, Molded Case Switches

DC

See Price List

+A-NZM 9 (120V 60Hz)


+A-NZM 9 (208V 60Hz)
+A-NZM 9 (240V 60Hz)
+A-NZM 9 (480V 60Hz)
+A-NZM 9 (600V 60 Hz)

See Price List

120 V 60 Hz
208 V 60 Hz
240 V 60 Hz
480 V 60 Hz
600 V 60 Hz

See Price List

51

AC
AC
AC
AC
AC

See Price List

53

See Price List

100% Continuous duty rating

See Price List

Shunt Trips

See Price List

See Price List

V/Hz

See Price List

See Price List

Ordering Information:
Voltage trips must be ordered with device. Add type from Column 4. Example: + U-NZM 9 (480V, 60 Hz).

For Immediate Delivery call KMParts.com at (866) 595-9616

8/27

Molded Case Circuit Breakers and Disconnect Switches


Accessories for NZM(H) 9...
1

Color
of
handle

Type
Can be used
with all devices
of Type number

Price

Fastens to shaft, not padlockable

Gray

NZM(H) 9...
N 9...

H 9U

Black

NZM(H) 9...
N 9...

H 9U-SW

Gray

NZM(H) 9...
N 9...

H 9-NA

Black

NZM(H) 9...
N 9...

H 9-SW-NA

Red/
Yellow

NZM(H) 9...
N 9...

RH 9-NA

NZM(H) 9...
N 9...

A-NZM 9

NZM(H) 9...
N 9...

SVB-NZM 9

NZM(H) 9...
N 9...

SA-NZM 9

NZM(H) 9...
N 9...

H9UZ

NZM(H) 9...
N 9...

KV-2 NZM 9

Handle for Cover/Door Interlocking

Circuit Breakers
Disconnect Switches, Molded Case Switches

Degree of protection UL/NEMA 3R, 12; IEC IP 55


Door coupling rotary handle. For front mounting in
doors and covers.
Can be locked in the OFF position with up to three
padlocks (hasp thickness 6 8 mm). Door/cover
interlocking supplied standard set in OFF position.
Can be field modified for setting in ON position.
3 distinct Handle positions: 0FF, + (tripped), ON
Red -Yellow version for Emergency-Stop function.

Extension shaft
For mounting depths of 190...400 mm.
Extends shaft length by 223 mm. Only one
extension shaft possible. Can also be used
with the mechanical interlock.

Padlocking accessory
Enables the device to be padlocked OFF when the
panel door is open. Accommodates up to 3 padlocks
(hasp size 1/4, 6 8mm).
A limit switch (Type AT0) can also be installed for
signalling or electrical interlocking purposes.

Switch position indicator


Indicates position of switch when panel door is open.

Maintenance Handle
To actuate the device when the panel door is open.

Mechanical Interlock
For mechanical interlocking of two devices.
Requires two handles, one for each switch.
Order separately.

Ordering Information:
Specify Type from Column 5. Example: H9-SW-NA
If ordering with device, just add a + in front of the Type number. Example: + H9-SW-NA

8/28

For Immediate Delivery call KMParts.com at (866) 595-9616

See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List

Handle for open or panel mounted devices

See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List

Molded Case Circuit Breakers and Disconnect Switches


Accessories for NZM(H) 9...
1

Color
of
handle

Can be used
Type
with all devices
of Type number To be ordered with
device only. Add
below suffix

Type

Price

NZM(H) 9...
N 9...

H 9-R-SW-NA

Red/
Yellow

NZM(H) 9...
N 9...

RH 9-R-NA

Specify desired text.


Height of letters: 3.5, 5, and 7 mm

NZM(H) 9...
N 9...

ZSSOND-NZM 9

Blank (for engraving or printing)

NZM(H) 9...
N 9...

ZS60-NZM 9

NZM(H) 9...
N 9...

ZS62-NZM 9

NZM(H) 9...
N 9...

ZS...-NZM 9

Afrikaans (81)
Finnish (66)
Italian (68)
Russian (74)

Bulgarian (64)
Czech (78)
French (63)
German (61)
Norwegian (70) Polish (71)
Serbo-Croatian (76) Spanish (77)

Danish (65)
Greek (69)
Portuguese (72)
Swedish (75)

Insert key number into Type. Example: ZS68-NZM 9


(Inscription in Italian language)

See Price List

See Price List

See Price List

See Price List

See Price List

Dutch (67)
Hungarian (80)
Romanian (73)
Turkish (79)

See Price List

Also available in other languages:

See Price List

Main Disconnect Warning plates.


English Inscription:
Main Switch- Open only in OFF position
Silver-colored, black lettering

See Price List

Silver-colored, black lettering

See Price List

Legend Plate (for mounting with


operating handle)

Ordering Information:
Specify Type from Column 5. Example: H9-R-SW-NA.
If ordering with device, just add a + in front of the Type number. Example: + H9-R-SW-NA
Note:
Items in Column 4 are factory installed and must be ordered with the device.

For Immediate Delivery call KMParts.com at (866) 595-9616

8/29

Circuit Breakers
Disconnect Switches, Molded Case Switches

Black

See Price List

H 9-R-NA

See Price List

See Price List

NZM(H) 9...
N 9...

Used with rear operation shaft.


Degree of protection: UL/NEMA 3R, 12; IEC IP 55
Can be locked in the OFF position with up to
three padlocks (hasp thickness 6 8 mm).
No cover/door interlocking provisions.
3 distinct Handle positions: 0FF, + (tripped), ON
Red -Yellow version for Emergency-Stop function.

See Price List

Gray

Operating Handle for rear operation

See Price List

+R-NZM 9

See Price List

NZM(H) 9...
N 9...

See Price List

For side panel mounting where device is only accessible


from the rear (e.g. sides of enclosure panels).
Must be combined with Type H...R rear operation handles.
Factory installed only. Order with device.

See Price List

Rear operation shafts

See Price List

Molded Case Circuit Breakers and Disconnect Switches


Handle kits for NZM(H) 9...
1

Type

Price

for CE marked control panels per IEC/EN 60 204-1

Type NZM(H) 9-... switches with dual UL/CSA and IEC/EN ratings are suitable for use as Main
Disconnect switches in control panels that must be CE marked and designed to comply with the
Machinery Directive standard EN 60 204-1.
The kits shown below, ordered with the device or separately, will provide the necessary accessories to
fulfill the Main Disconnect switch function for these applications.
Note: In cases where the Main Disconnect switch also fulfills the Emergency-Stop function, please
specify kits containing red handle and yellow backing plate assemblies.

Circuit Breakers
Disconnect Switches, Molded Case Switches

Kit includes:
Main Disconnect handle with door/cover interlock for front mounting,
red color handle with yellow backing plate for Emergency-Stop function,
terminal cover and Main Switch marking plate.

Kit includes:
Main Disconnect handle for rear operated switches, red in color with
yellow backing plate for Emergency-Stop function, supplied with a
steel plate for panel side-mounting, terminal cover and Main Switch
marking plate

Kit includes:
Same as V-NZM 9, except that the Main Disconnect handle is
black in color with silver backing plate for standard,
non-Emergency-Stop function.

Kit includes:
Same as EA-NZM 9, except that the Main Disconnect handle is
black in color with silver backing plate for standard,
non-Emergency-Stop function.

V-NZM 9

EA-NZM 9

V-NZM 9-SW

EA-NZM 9-SW

Ordering Information:
Specify Type from Column 3. Example: V- NZM 9
If ordering with device, just add a + in front of the Type number. Example: + V- NZM 9

8/30

For Immediate Delivery call KMParts.com at (866) 595-9616

See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List

Main Disconnect Switch Assembly Kits

See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List

Molded Case Circuit Breakers and Disconnect Switches


Accessories for NZM(H) 9...
1

Type

Type

Price

To be ordered with
device only. Add
suffix shown below

H-NZM 9

Circuit Breakers
Disconnect Switches, Molded Case Switches

Provides shock hazard protection in the area of the field wiring


power terminals. Can be used at top or bottom, one cover per side.
Mandatory requirement on the supply side of Main Disconnect
switches to provide protection against accidental contact with line
side feed.

See Price List

Terminal Cover

See Price List

See Price List

+ST

See Price List

Supplementary terminals attached to main terminals.


3 connections top and bottom. Factory addition only, must be
ordered with device.

See Price List

Control Circuit Tap-Off Terminals

See Price List

Ordering Information:
Accessory in Column 2 can only be ordered with device. Specify Type suffix. Example: + ST
Specify Type from Column 3. Example: H-NZM 9
If ordering with device, just add a + in front of the Type number. Example: + H-NZM 9

For Immediate Delivery call KMParts.com at (866) 595-9616

8/31

Inverse Time Circuit Breakers, 1000 Amps


Solid State Trip, Type NZM 12...-NA
1

UL/CSA

Long Time
Response
Current
Setting

Adjustable
instantaneous
Pick-up
Setting

Adjustable
Short Time Delay
Pick-up setting
for selectivity in
networks

UL/CSA Interrupting
ratings (AC, 60Hz)

Type

Price

RMS Sym Amps @

Standard

65 kA

65 kA

50 kA

NZM 12-630/ZM 12A-400-NA


NZM 12-630/ZM 12A-500-NA
NZM 12-630/ZM 12A-600-NA
NZM 12-800/ZM 12A-700-NA
NZM 12-800/ZM 12A-800-NA
NZM 12-1250/ZM 12A-1000-NA

65 kA

65 kA

50 kA

NZM 12-630/ZM 12-600-NA


NZM 12-800/ZM 12-800-NA
NZM 12-1250/ZM 12-1000-NA

65 kA

65 kA

50 kA

Fixed Long Time Response Setting


Type NZM 12-.../ZM 12A-...-NA
400
500
600
700
800
1000

1200 12,000
1200 12,000
1200 12,000
1600 16,000
1600 16,000
2000 20,000

Adjustable Long Time Response Setting


Type NZM 12-.../ZM 12-...-NA
300 600
400 800
500 1000

Type NZM 12-.../ZM 12 V-...-NA

300 600
400 800
500 1000

1200 12,000
1600 16,000
2000 20,000

600 7200
800 9600
1000 12,000

NZM 12-630/ZM 12 V-600-NA


NZM 12-800/ZM 12 V-800-NA
NZM 12-1250/ZM 12 V-1000-NA

(1000 A)

See Price List

Adjustable Long Time response setting and


Short-Time Delay pick-up for selectivity

See Price List

(1000 A)

See Price List

See Price List

1200 12,000
1600 16,000
2000 20,000

See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

(1000 A)

See Price List

600 V

See Price List

480 V

See Price List

240 V

See Price List

Amps

See Price List

Amps

See Price List

Amps

See Price List

Time delay Range:


0 1000 ms

Type NZM 12-.../ZM 12(A)-...-NA Molded Case Circuit Breakers are UL Listed (UL 489) and CSA Certified (22.2 Nr. 5.1) Inverse Time, Solid State
Trip Circuit Breakers with a fixed or adjustable Long Time Response and adjustable instantaneous pick-up range.
Type NZM 12-.../ZM 12 V-...-NA are UL Listed (UL 489) and CSA Certified (22.2 Nr. 5.1) and have an additional short time delay pick-up range for
selectivity in energy distribution networks. The time delay response is adjustable from 0 to 1000 milliseconds.

Ordering Information:
State type from Column 6. Example: NZM 12-1250/ZM 12A-1000-NA.
Note:
- Operating Handle supplied separately. Consult page 8/36 for available handle types.
- Consult page 8/34 - 39 for additional accessories.
- Line and Load field-wiring terminals for cable connection supplied as standard. Refer to technical data for range of suitable conductor
cross-sections.

8/32

For Immediate Delivery call KMParts.com at (866) 595-9616

Continuous
Current
Rating

Maximum HP Rating
3 Phase @

Type

Price

Amps

200 V 230 V
HP
HP

460 V
HP

575 V
HP

200
250
250
300

450
600
600
1000

600
750
750
1000

600
800
1000
1200

250
300
300
450

N 12-630-CNA
N 12-800-CNA
N 12-1000-CNA
N 12-1200-CNA 1)

See Price List

N12-...-CNA Motor Disconnect Switches

See Price List

$
See Price List

Frame
Rating

See Price List

Motor Disconnect Switches, 1200 Amps


Type N12-...-CNA

Type N 12...-CNA Disconnect Switches are UL recognized (UL 508) and CSA certified (22.2 Nr. 14) as 3 pole, HP rated non-automatic manual
motor disconnects without any overload or short circuit tripping elements.
Their switching mechanism has 3 positions (OFF, ON, + Tripped) and they can be equipped with voltage trip accessories such as shunt trip and
undervoltage trip coils.
UL/CSA Short Circuit Rating @ 600VAC: 42 kA RMS Sym.

Circuit Breakers
Disconnect Switches, Molded Case Switches

UL/CSA, IEC/EN 60 947-3

Ordering Information:
State type from Column 4. Example: N 12-800-CNA
Note:
- For direct-on-line switching of motors, use in combination with a listed magnetic contactor.
- Operating Handle supplied separately. Consult page 8/36 for available handle types.
- Consult page 8/34 - 39 for additional accessories.
- Line and Load field-wiring terminals for cable connection supplied as standard.
1) N 12-1200-CNA is supplied standard with bolt-on connection only. Field-wiring terminals for conductor hook-up
(up to 4 x 500 kcmil, Cu or Al) can be supplied but must be ordered with the device. Add the following suffixes to the Type number.
Example: N 12 -1200-CNA
+ K 240AL-NZM 12-O (for top mounted terminals, set of three)
+ K 240AL-NZM 12-U (for bottom mounted terminals, set of three)
See price list for adder.

For Immediate Delivery call KMParts.com at (866) 595-9616

8/33

Molded Case Circuit Breakers and Disconnect Switches


Auxiliary Contacts for NZM 12...
1

Contacts

Type

Price

Notes

To be ordered with
device only.
Add below suffix.

+VHI 21-NZM 12

31 35 37

Circuit Breakers
Disconnect Switches, Molded Case Switches

Handle operated Early-Make Auxiliary Contacts


22 26 28
2
1

+AHI 21-NZM 12

21 25 27

Trip Indicating Auxiliary Contacts


42 46 48
2

+RHI 21-NZM 12

41 45 47

See Price List

32 36 38

See Price List

Early-Make Auxiliary Contacts

See Price List

11 15 13 17

See Price List

+NHI 22-NZM 12

See Price List

See Price List

12 16 14 18

See Price List

Standard Auxiliary Contacts

See Price List

N.O. N.C.
1)

Combination possibilities of
auxiliary contacts:
NHI
VHI
AHI

RHI

Dots in each row represent the types which can


be combined together. Dashes indicate incompatibility.

1) The NHI 22-NZM 12 auxiliary contact comes standard with all versions
of the NZM 12-.../ZM 12...-NA Molded Case Circuit Breakers. It is an
optional accessory only for the non-automatic N 12-...-CNA disconnect
switches and must be ordered with the device if desired.

Type NHI... are standard auxiliary contacts. They operate simultaneously with the main contacts. They can be typically used for signalling or
switching auxiliary circuits such as a control circuit.
Type VHI... are Early Make auxiliary contacts and lead the main contacts when switching ON as well as switching OFF. This makes them ideal for
load shedding purposes or in conjunction with voltage trips in control circuits.
Type AHI... are handle operated Early Make auxiliary contacts. They operate in advance of the main contacts, shortly after the handle has left the
OFF position. They can be typically used to convert the manual actuation of the switch into a control function for circuit interlocking purposes.
Type RHI... are trip indicating auxiliary contacts. They work independently of the normal ON and OFF operations of the device, switching only when
the device has tripped due to overloads, overcurrents or other tripping functions such as voltage trips.
Refer to diagrams below for further details:

NHI
Same as main contacts

Position of auxiliary contacts


Main
Contacts:
Closed
Open

VHI
Same contact position
in both OFF and Tripped
position of the device.

Switching ON
I
Switching OFF
I

Tripped position
+
I

AHI
RHI
Operates only when
Same contact position
in both ON and Tripped device is tripped
(overload, short-circuit,
position of the device.
shunt or undervoltage
trips.)

L1L2L3

L1L2L3

L1L2L3

L1L2L3

NHI

VHI

AHI

RHI

L1L2L3

L1L2L3

L1L2L3

L1L2L3

NHI

VHI

AHI

RHI

L1L2L3

L1L2L3

L1L2L3

L1L2L3

NHI

VHI

AHI

RHI

Ordering Information:
Auxiliary Contacts must be ordered with device. Add type from Column 3.
Example: + VHI 21-NZM 12.

8/34

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit Breakers and Disconnect Switches


Voltage Trips for NZM 12...
3

Rated
Control
Voltage

Type

Price

Notes

To be ordered with device only.


Add below suffix.

24 V

+A-NZM 12 (24V DC)

AC
AC
AC
AC
AC

120V 60Hz
208V 60Hz
240V 60Hz
480V 60Hz
600V 60Hz

+U-NZM 12 (120V 60Hz)


+U-NZM 12 (208V 60Hz)
+U-NZM 12 (240V 60Hz)
+U-NZM 12 (480V 60Hz)
+U-NZM 12 (600V 60Hz)

DC

24V

+U-NZM 12 (24VDC)

Undervoltage Trips
52
U <
51

Shunt Trips are typically used to electrically


trip the device from a remote location.
The A-NZM 12... series is rated for 100%
continuous duty. If desired, automatic
disconnection of the shunt trip coil can be
achieved by using the NHI auxiliary contact in
series with the coil.
Shunt Trips cannot be mounted together with
Undervoltage Trips.

Undervoltage Trips will electrically trip the


device open under power loss and can be
used for control interlocking purposes e.g. to
disconnect the main switch in EmergencyStop circuits. They are rated for continuous
duty. Power can be applied to the
undervoltage trip using VHI early-make
auxiliary contacts in series with the
undervoltage trip coil.
Undervoltage Trips cannot be mounted
together with Shunt Trips.

Circuit Breakers
Disconnect Switches, Molded Case Switches

DC

See Price List

+A-NZM 12 (120V 60Hz)


+A-NZM 12 (208V 60Hz)
+A-NZM 12 (240V 60Hz)
+A-NZM 12 (480V 60Hz)
+A-NZM 12 (600V 60Hz)

See Price List

120V 60Hz
208V 60Hz
240V 60Hz
480V 60Hz
600V 60Hz

See Price List

51

AC
AC
AC
AC
AC

See Price List

53

See Price List

100% Continuous duty rating

See Price List

Shunt Trips

See Price List

See Price List

V/Hz

See Price List

See Price List

Ordering Information:
Voltage trips must be ordered with device. Add type from Column 4.
Example: + U-NZM 12 (480V, 60Hz)

For Immediate Delivery call KMParts.com at (866) 595-9616

8/35

Molded Case Circuit Breakers and Disconnect Switches


Accessories for NZM 12...
1

Color
of
handle

Can be used
with all devices
of Type number

Type

Price

A-NZM 12

N(ZM)12...

SA-NZM 12

Circuit Breakers
Disconnect Switches, Molded Case Switches

N(ZM)12...

H 12UZ

For mechanical interlocking of two devices mounted


side by side. Requires two handles, one for each
switch. Order separately.

N(ZM)12...

KV-2 NZM 12

For mechanical interlocking of two devices not


mounted side by side. Requires two handles, one
for each switch. Order separately.

N(ZM)12...

KVA-2 NZM 12

For mechanically interlocking two main incomers with


one emergency-supply device e.g. in emergency
power supply systems. Handles ordered separately.

N(ZM)12...

KVA-3 NZM 12

For mounting depths of 240 400 mm.


Extends shaft length by 183 mm. Only one
extension shaft possible. Can also be used
with the mechanical interlock.

Switch position indicator


Indicates position of switch when panel door is open.

Maintenance Handle
To actuate the device when the panel door is open.

Mechanical Interlock

Ordering Information:
Specify Type from Column 5. Example: H 12-SW-NA
If ordering with device, just add a + in front of the Type number. Example: + H 12-SW-NA

8/36

For Immediate Delivery call KMParts.com at (866) 595-9616

See Price List

N(ZM)12...

Extension shaft

See Price List

RH 12-NA

See Price List See Price List

N(ZM)12...

See Price List

Red/
Yellow

See Price List

H 12-SW-NA

See Price List

N(ZM)12...

See Price List

Black

See Price List

H 12-NA

See Price List

N(ZM)12...

Degree of protection UL/NEMA 3R, 12; IEC IP 55


Door coupling rotary handle. For front mounting in
doors and covers.
Can be locked in the OFF position with up to three
padlocks (hasp thickness 6 8 mm). Door/cover
interlocking supplied standard set in OFF position.
Can be field modified for setting in ON position.
3 distinct Handle positions: 0FF - + (tripped) - ON
Red -Yellow version for Emergency-Stop function.

See Price List

Gray

Handle for Cover/Door Interlocking

See Price List

H 12U-SW

See Price List

N(ZM)12...

See Price List

Black

See Price List

H 12U

See Price List

N(ZM)12...

See Price List

Gray

See Price List

Fastens to shaft, not padlockable

See Price List

Handle for open or panel mounted devices

See Price List

Molded Case Circuit Breakers and Disconnect Switches


Accessories for NZM 12...
1

Color Can be used


of
with all devices
handle of Type number

Type
To be ordered with
device only. Add
below suffix

Type

Price

N(ZM) 12...

ZSSOND-NZM 12

Blank (for engraving or printing)

N(ZM) 12...

ZS60-NZM 12

Main Disconnect Warning plates.


English Inscription:
Main Switch- Open only in OFF position
Silver-colored, black lettering

N(ZM) 12...

ZS62-NZM 12

Also available in other languages:

N(ZM) 12...

ZS...-NZM 12

(for mounting with operating handle)


Silver-colored, black lettering

Afrikaans (81)
Finnish (66)
Italian (68)
Russian (74)

Bulgarian (64)
Czech (78)
French (63)
German (61)
Norwegian (70)
Polish (71)
Serbo-Croatian (76) Spanish (77)

Danish (65)
Greek (69)
Portuguese (72)
Swedish (75)

Dutch (67)
Hungarian (80)
Romanian (73)
Turkish (79)

Insert key number into Type. Example: ZS63-NZM 12


(Inscription in French language)

Circuit Breakers
Disconnect Switches, Molded Case Switches

Specify desired text.


Height of letters: 3.5, 5, and 7 mm

Legend Plate

See Price List

RH 12-R-NA

See Price List

See Price List

N(ZM) 12...

See Price List

Red/
Yellow

See Price List

H 12-R-SW-NA

See Price List

See Price List

N(ZM) 12...

See Price List

Black

See Price List

H 12-R-NA

See Price List

See Price List

N(ZM) 12...

Used with rear operation shaft.


Degree of protection:
UL/NEMA 3R, 12; IEC IP 55
Can be locked in the OFF position with up to
three padlocks (hasp thickness 6 8 mm).
No cover/door interlocking provisions.
3 distinct Handle positions: 0FF - + (tripped) - ON
Red -Yellow version for Emergency-Stop function.

See Price List

Gray

Operating Handle for rear operation

See Price List

+R-NZM 12

See Price List

N(ZM) 12...

See Price List

For side panel mounting where device is only


accessible from the rear (e.g. sides of enclosure panels).
Must be combined with Type H...R rear operation
handles.
Factory installed only. Order with device.

See Price List

Rear operation shafts

See Price List

See Price List

Ordering Information:
Specify Type from Column 5. Example: H 12-R-SW-NA.
If ordering with device, just add a + in front of the Type number. Example: + H 12-R-SW-NA
Note:
Items in Column 4 are factory installed and must be ordered with the device.

For Immediate Delivery call KMParts.com at (866) 595-9616

8/37

Molded Case Circuit Breakers and Disconnect Switches


Accessories for NZM 12...
1

Type

Type

Price

To be ordered with
device only. Add
suffix shown below

H-NZM 12

P-NZM

Circuit Breakers
Disconnect Switches, Molded Case Switches

Test Unit for NZM 12 Circuit-Breakers


Supply terminal voltage can be selected from 120/220/240 V, 50/60 Hz
The portable test unit can be used to verify that the long time,
instantaneous and short-time delayed tripping characteristics of the
circuit-breaker are operating per preset values. Various test voltages
simulate a short-circuit or an overload condition which would cause the
circuit-breaker to trip out.
All measuring and connection leads, as well as operating instructions,
are supplied with the unit.

Ordering Information:
Accessory in Column 2 can only be ordered with device. Specify Type suffix. Example: + ST
Specify Type from Column 3. Example: H-NZM 12
If ordering with device, just add a + in front of the Type number. Example: + H-NZM 12

8/38

For Immediate Delivery call KMParts.com at (866) 595-9616

See Price List See Price List See Price List See Price List

Provides shock hazard protection in the area of the field wiring


power terminals. Can be used at top or bottom, one cover per side.
Mandatory requirement on the supply side of Main Disconnect
switches to provide protection against accidental contact with line
side feed.

See Price List

Terminal Cover

See Price List

See Price List

+ST

See Price List

Supplementary terminals attached to main terminals. 3 connections


top and bottom. Factory addition only, must be ordered with device.

See Price List

Control Circuit Tap-Off Terminals

See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

Notes

For Immediate Delivery call KMParts.com at (866) 595-9616

8/39

Molded Case Circuit Breakers and Switches


Type NZM 7... Overview

UL / CSA / IEC/EN 60 947 / CE

Circuit Breakers
Disconnect Switches, Molded Case Switches

8
6
1
2

7
5

8/40

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit Breakers and Switches


Type NZM 7... Overview
Molded Case Breaker Page 8/44

480 V AC, 150 Amp rating


25 kA @ 480 VAC Interrupting rating
Field installable accessories
Supplied with terminals for cable hookup or
bolt-on connection.
UL Listed (UL 489), CSA certified (C 22.2 # 5.1)
Conformity with (Circuit Breakers) IEC/EN 60 947-2 (pending)

Molded Case Switch Page 8/45

Enables mounting of the NZM 7 on a DIN rail conforming to


EN 50 022 specifications.

Auxiliary Contacts Page 8/46

(Pictured right of toggle switch)


Type NHI... standard auxiliary contact:
For signalling ON and OFF positions
Type RHI... trip-indicating auxiliary contact:
For signalling the Tripped (+) position

Auxiliary Contacts & Voltage Trips Page 8/47...49


(Pictured left of toggle switch)
Type VHI... Early-Make auxiliary contact:
For interlocking and load shedding purposes.
To power up the undervoltage trip prior to main contact closing
Shunt Trips
AC & DC versions
With and without Early-Make auxiliary contacts
Undervoltage Trips
AC & DC versions
With and without Early-Make auxiliary contacts

Rotary Drive Mechanism Page 8/50


Converts toggle switch operation of the switch into a rotary
movement suitable for rotary style operators.
Lockable in the OFF position. (Optional)

600 VAC, 200 Amp rating


Field installable accessories
UL Listed (UL 1087), CSA certified (C 22.2 # 5.2)
Conformity with IEC/EN 60 947-3 (Switch-Disconnectors)

Clip Plate Page 8/52

Circuit Breakers
Disconnect Switches, Molded Case Switches

Rotary Handle Page 8/50


To operate switch equipped with rotary drive mechanism.

Door/Cover Interlocking Rotary Handle Page 8/50


For cover or door mounting.
Interlocking feature to prevent opening of door or cover with the switch
in the ON position.
Padlockable in the OFF or ON position with up to 3 padlocks (hasp
size: 1/4, 4 8mm). (Optional. Also comes without padlockable
feature.)
Standard color: Black. Also available in red-yellow for Emergency-Stop
function per CE and IEC/EN 60 204-1 specifications.
Degree of protection: UL/NEMA 12, IEC/EN: IP 55.

Terminal Cover Page 8/53


Provides shock hazard protection against accidental
contact with live terminals.
Mandatory use in Main Disconnect switch applications
for CE panels in conformity with IEC/EN 60 204-1

For Immediate Delivery call KMParts.com at (866) 595-9616

8/41

Molded Case Circuit Breakers and Switches


Overview of Combination Options for Type NZM 7...
Auxiliary contacts

Voltage Trips

(NHI...: Standard)
(RHI...: Trip Indicating)
(VHI...: Early-Make)

EK...
(NHI)

Circuit Breakers
Disconnect Switches, Molded Case Switches

EK...
(RHI)

VHI-NZM 7

Molded Case Circuit Breakers

NZM 7(A)...N-NA

Molded Case Switches


NZM 7...-NA

Molded Case Circuit Breakers


+ Remote Control Drive

NZM 7(A)...N-NA + R-NZM 7

Molded Case Switches


+ Remote Control Drive
NZM 7...-NA + R-NZM 7

(A...: Shunt Trip)


(AVHI...: Shunt Trip with Early-Make Auxiliary Contact)
(U...: Undervoltage Trip)
(UHI...: Undervoltage Trip with Early-Make Auxiliary Contact)

A-NZM 7

AVHI-NZM 7

U-NZM 7

or

or

or

or

or

or

or

or

or

or

Dots in each row represent the accessories which can be combined together in the types shown at left.
Circles indicate supplied as standard.

Dashes indicate incompatibility.


All accessories can be field or factory installed.

8/42

UHI NZM 7

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit Breakers and Switches


Overview of Combination Options for Type NZM 7...

RNZM 7

Handle Operators

Connection systems

Cable Terminals
(included as
standard)

Bolt-on Connection
(Optional)

Rotary
Rotary
Drive
handle
Mechanism

Cover/Door Interlocking
Rotary handle
NEMA/UL Type 12; IP 55

DA(OV)NZM 7

HU(Z)NZM 7

(R)HNZM 7

HOVNZM 7

NZM 7(A)...N-NA-M8
NZM 7 ...-NA-M8

or

or

or

or

or

or

Circuit Breakers
Disconnect Switches, Molded Case Switches

Remote
Control
Drive

For Immediate Delivery call KMParts.com at (866) 595-9616

8/43

UL/CSA, IEC/EN 60 947-21)

Inverse Time Circuit Breakers, 150 Amps, 600 VAC


Thermal-Magnetic Type NZM 7...S-NA
4

Adjustable
Thermal
Setting

Magnetic
Trip Setting
for Instantaneous
Response

UL/CSA Interrupting
ratings (AC, 60Hz)

Type

Price

Amps

Amps

240V 480V 600V

40
60
80
100
125
150

25 40
40 60
60 80
80 100
100 125
125 150

9.5 x Iu
6 12 x Iu

Fixed thermal setting and provisions for bolt-on connection


Type NZM 7A-...S-NA
40

60
80

100
125
150

25
30
35
40
50
60
70
80
90
100
125
150

Fixed:
9.5 x Iu

100kA 50kA 22kA

Adjustable Range:
6 12 x Iu

NZM 7A-25S-NA-M8
NZM 7A-30S-NA-M8
NZM 7A-35S-NA-M8
NZM 7A-40S-NA-M8
NZM 7A-50S-NA-M8
NZM 7A-60S-NA-M8
NZM 7A-70S-NA-M8
NZM 7A-80S-NA-M8
NZM 7A-90S-NA-M8
NZM 7A-100S-NA-M8
NZM 7A-125S-NA-M8
NZM 7A-150S-NA-M8

Adjustable thermal setting and provisions for bolt-on connection


Type NZM 7-...S-NA
40
60
80
100
125
150

25 40
40 60
60 80
80 100
100 125
125 150

9.5 x Iu
6 12 x Iu

100kA 50kA 22kA

NZM 7-40S-NA-M8
NZM 7-63S-NA-M8
NZM 7-80S-NA-M8
NZM 7-100S-NA-M8
NZM 7-125S-NA-M8
NZM 7-150S-NA-M8

Ordering Information: Specify Type from Column 7.


Example: NZM 7A-25S-NA
For accessories see pages 8/46 - 53 in the Main Catalog USA 2000 / 2001

1) Conformity with IEC/EN 60 947-2 pending.

8/44

For Immediate Delivery call KMParts.com at (866) 595-9616

See Price List

NZM 7-40S-NA
NZM 7-63S-NA
NZM 7-80S-NA
NZM 7-100S-NA
NZM 7-125S-NA
NZM 7-150S-NA

Pressure-wire terminals and adjustable thermal setting


Type NZM 7A-...S-NA

See Price List

100kA 50kA 22kA

Adjustable Range:
6 12 x Iu

See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

125
150

NZM 7A-25S-NA
NZM 7A-30S-NA
NZM 7A-35S-NA
NZM 7A-40S-NA
NZM 7A-50S-NA
NZM 7A-60S-NA
NZM 7A-70S-NA
NZM 7A-80S-NA
NZM 7A-90S-NA
NZM 7A-100S-NA
NZM 7A-125S-NA
NZM 7A-150S-NA

See Price List

100

100kA 50kA 22kA

See Price List

80

Fixed: 9.5 x Iu

See Price List

(150A)

See Price List

60

25
30
35
40
50
60
70
80
90
100
125
150

See Price List

40

See Price List

Pressure-wire terminals and fixed thermal setting


Type NZM 7A-...S-NA

See Price List

See Price List

Amps

See Price List

Amps

RMS Sym Amps @

See Price List

Iu

See Price List

Continuous Fixed
Thermal
Current
Setting
Rating

See Price List

See Price List

UL/CSA, IEC/EN 60 947-21)

Inverse Time Circuit Breakers, 150 Amps, 480 VAC


Thermal-Magnetic Type NZM 7...-NA
1

Continuous Fixed
Thermal
Current
Setting
Rating

Adjustable
Thermal
Setting

Magnetic
Trip Setting
for Instantaneous
Response

UL/CSA Interrupting
ratings (AC, 60Hz)

Type

Price

Amps

Amps

240 V

480 V

65 kA

25 kA

RMS Sym Amps @

Iu

40

25 40

9.5 x Iu

60
80
100
125
150

40 60
60 80
80 100
100 125
125 150

6 12 x Iu

65 kA

25 kA

NZM 7-40N-NA
NZM 7-63N-NA
NZM 7-80N-NA
NZM 7-100N-NA
NZM 7-125N-NA
NZM 7-150N-NA

Fixed thermal setting and provisions for bolt-on connection


Type NZM 7A-...N-NA

40

25
30
35
40

Fixed:
9.5 x Iu

60

50
60
70
80
90
100
125
150

Adjustable Range:
6 12 x Iu

80
100
125
150

65 kA

25 kA

NZM 7A-25N-NA-M8
NZM 7A-30N-NA-M8
NZM 7A-35N-NA-M8
NZM 7A-40N-NA-M8
NZM 7A-50N-NA-M8
NZM 7A-60N-NA-M8
NZM 7A-70N-NA-M8
NZM 7A-80N-NA-M8
NZM 7A-90N-NA-M8
NZM 7A-100N-NA-M8
NZM 7A-125N-NA-M8
NZM 7A-150N-NA-M8

Adjustable thermal setting and provisions for bolt-on connection


Type NZM 7-...N-NA
40

25 40

9.5 x Iu

60
80
100
125
150

40 60
60 80
80 100
100 125
125 150

6 12 x Iu

65 kA

25 kA

NZM 7-40N-NA-M8
NZM 7-63N-NA-M8
NZM 7-80N-NA-M8
NZM 7-100N-NA-M8
NZM 7-125N-NA-M8
NZM 7-150N-NA-M8

Ordering Information: Specify Type from Column 7.


Example: NZM 7A-25N-NA.
1) Conformity with IEC/EN 60 947-2 pending. Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings.

8/44a

For Immediate Delivery call KMParts.com at (866) 595-9616

See Price List


See Price List
See Price List

Pressure-wire terminals and adjustable thermal setting


Type NZM 7A-...N-NA

See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

125
150

See Price List

100

See Price List

80

NZM 7A-50N-NA
NZM 7A-60N-NA
NZM 7A-70N-NA
NZM 7A-80N-NA
NZM 7A-90N-NA
NZM 7A-100N-NA
NZM 7A-125N-NA
NZM 7A-150N-NA

See Price List

Adjustable Range:
6 12 x Iu

See Price List

See Price List

50
60
70
80
90
100
125
150

See Price List

60

NZM 7A-25N-NA
NZM 7A-30N-NA
NZM 7A-35N-NA
NZM 7A-40N-NA

See Price List

Fixed: 9.5 x Iu

See Price List

See Price List

25
30
35
40

See Price List

(150A)

40

See Price List

Pressure-wire terminals and fixed thermal setting


Type NZM 7A-...N-NA

See Price List

See Price List

Amps

See Price List

Amps

UL/CSA, IEC/EN 60 947-3


1

Molded Case Switches, 200Amps, 600 VAC


Type NZM 7...-NA

Ampere
Rating

Type

Price

Notes

200

NZM 7-200-NA

Molded Case Switches


With provisions for bolt-on connection
60

NZM 7-60-NA-M8

100

NZM 7-100-NA-M8

125

NZM 7-125-NA-M8

150

NZM 7-150-NA-M8

200

NZM 7-200-NA-M8

With 225 A Fuse Backup:


- 50 kA RMS Sym @ 600 VAC
With 250 A Circuit-Breaker Backup:
- 25 kA RMS Sym @ 480 VAC
- 18 kA RMS Sym @ 600 VAC

Type NZM 7(A)-...-NA(M8) Molded Case Circuit Breakers (opposite page) are UL Listed (UL 489) and CSA Certified (22.2 Nr. 5.1) Inverse Time,
150A Thermal-Magnetic Circuit Breakers that are available with either a fixed or adjustable thermal trip feature and an adjustable magnetic trip
function. (In Breakers rated 25 to 40 Amp, the magnetic trip function is fixed at 9.5 x 40A (Iu) i.e. 385A).
Type NZM 7-...-NA(-M8) Molded Case Switches (shown above) are virtually identical in construction to the Molded Case Circuit Breakers except that
they are manual, non-automatic switches without any overload or overcurrent protective features, and are rated up to 200Amps.
All Molded Case Switches are UL Listed (UL 1087) and CSA certified (C 22.2 Nr. 5.2). They also are in Conformity with IEC/EN 60 947-3 (SwitchDisconnectors) and are CE marked. (Consult the Technical Data at the end of this section and Moeller Electric for IEC/EN ratings.)
Molded Case Switches are tested to determine their acceptability for continuous operation at their marked rated load. In addition, they are tested at
six times their full ampere rating to cover motor circuit applications and are suitable for use as motor circuit disconnects per Section 430-109 of the
National Electrical Code.
Both breakers and switches are supplied as standard with pressure wire terminals to accept cable connection, but are also suitable for bolt-on
connections using crimped lugs or straight lengths of Cu busbar (Type suffix -M8).
Accessories such as voltage trips, auxiliary contacts, rotary handles etc... are common to all NZM 7 circuit breakers and molded case switches and
are UL listed and CSA certified for field installation.

Ordering Information:
Specify Type from Column 3. Example: NZM 7-60-NA.

For Immediate Delivery call KMParts.com at (866) 595-9616

8/45

Circuit Breakers
Disconnect Switches, Molded Case Switches

NZM 7-150-NA

See Price List

150

See Price List

NZM 7-125-NA

UL/CSA Short Circuit Current Rating:

See Price List

125

See Price List

NZM 7-100-NA

See Price List

100

See Price List

NZM 7-60-NA

See Price List

60

See Price List

With pressure wire terminals for cable connection

See Price List

Molded Case Switches

See Price List

Amps

Molded Case Circuit Breakers and Switches


Auxiliary Contacts for Type NZM 7...-NA
1

Contact
sequence

Type

Price

Notes

2X
E.M.

VHI-NZM 7

N.O.

EK 10

1.12

VHI

Circuit Breakers
Disconnect Switches, Molded Case Switches

Early-Make auxiliary contacts


Leading the main contacts when switching ON as well as
switching OFF. Ideal for load shedding purposes or in
conjunction with voltage trips in control circuits.

3.14 3.34

RHI
Trip-indicating auxiliary contacts
Actuating independently of the normal ON and OFF operations of the device, switching only when the device has tripped
due to overcurrents or other tripping causes such as those
initiated by voltage trips.

4.13

4.14

4.13

N.C.
EK 01

4.14

Auxiliary Contacts are field installable.

3.13 3.33

Ordering information:
Specify Type from column 4.
Example: EK 10
If ordering with device, just specify a + in front of the Type
number. Example: + EK 10

See Price List

EK 01

See Price List

1.11

See Price List

N.C.

1.14

See Price List

EK 10

See Price List

N.O.

See Price List

be typically used for signalling, interlocking or switching


auxiliary circuits such as a control circuit.

1.13

See Price List

Switching simultaneously with the main contacts. They can

See Price List

Standard auxiliary contacts

See Price List

NHI

See Price List

Two EK... NHI type contacts can be


snap fitted into the Circuit Breaker or
Molded Case Switch.

One VHI...Type contact module per


Circuit Breaker or Molded Case
Switch.
Cannot be used in conjunction with the
R-NZM 7 Remote Control Drive.

One EK... RHI type contact (either


N.O. or N.C.) can be snap fitted into
the Circuit Breaker or Molded Case
Switch for trip indication.

Auxiliary Contacts and Voltage Trips can be combined as follows:


NHI
2 x EK...

RHI
1 x EK...

VHI

AVHI

U(V)HI

Dots in each row represent the types which can be combined together. Dashes indicate
incompatibility.

8/46

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit Breakers and Switches


Remote Control Drive and Shunt Trips for Type NZM 7...-NA
2

Rated
Actuating
Voltage
(US)

Type

Price

Notes

A-NZM 7 (12V)
A-NZM 7 (24V)
A-NZM 7 (48V)
A-NZM 7 (60V)
A-NZM 7 (110-120V)
A-NZM 7 (125-130V)
A-NZM 7 (208-215V)
A-NZM 7 (220-240V)
A-NZM 7 (380-415V)
A-NZM 7 (440-480V)

AC/DC1)

12
24
48
60
110-120
125-130
208-215
220-240
380-415
440-480

AVHI-NZM 7 (12V)
AVHI-NZM 7 (24V)
AVHI-NZM 7 (48V)
AVHI-NZM 7 (60V)
AVHI-NZM 7 (110-120V)
AVHI-NZM 7 (125-130V)
AVHI-NZM 7 (208-215V)
AVHI-NZM 7 (220-240V)
AVHI-NZM 7 (380-415V)
AVHI-NZM 7 (440-480V)

C1
C2

Shunt Trips with Early-Make auxiliary contacts


C1

3.13

C2

3.14

See Price List


See Price List

L1(L+)
0
S

L1(L+)
0

70
R-NZM 7
74

H1

H1
70

71 72

71 72

R-NZM 7
74

75

N(L-, L2)

N(L-, L2)

3-wire control

2-wire control

75

L1(L+)
0

H1

RHI

70

3-wire control with automatic reset


to the OFF position after the circuitbreaker has tripped

71 72

R-NZM 7
74

75

N(L-, L2)

Field installable and suitable for mounting into


NZM 7 Circuit Breakers and Molded Case
Switches.
Shunt Trips are rated for both AC and DC voltages and can accommodate a frequency
range between 0 and 400 Hz.

Field installable and suitable for mounting into


NZM 7 Circuit Breakers and Molded Case
Switches.
Shunt Trips are rated for both AC and DC
voltages and can accommodate a frequency
range between 0 and 400 Hz.
The Shunt Trip and Early-Make contacts
operate independently of one another.
Note:
The Early-Make feature of the contact is not
effective when it is combined with the
R-NZM 7 Remote Control Drive.

Accessories are field installable.

Auxiliary Contacts and Voltage Trips can be combined as follows:

Ordering information:
Specify Type from column 3.
Example: A-NZM 7 (110-120V)

NHI
2 x EK...

RHI
1 x EK...

VHI

AVHI

U(V)HI

If ordering with device, just specify a + in front of the Type


number.
Example: + A-NZM 7 (110-120V)

Dots in each row represent the types which can be combined together. Dashes indicate
incompatibility.

1) Maximum UL/CSA DC voltage is 125 VDC.

For Immediate Delivery call KMParts.com at (866) 595-9616

8/47

Circuit Breakers
Disconnect Switches, Molded Case Switches

12
24
48
60
110-120
125-130
208-215
220-240
380-415
440-480

See Price List

1)

See Price List

AC/DC

See Price List

Shunt Trips without Auxiliary Contacts

See Price List

Shunt Trips are typically used to electrically trip the device


from a remote location. The A...- NZM 7 series is rated for
100% continuous duty. Shunt Trips cannot be mounted
together with Undervoltage Trips.

See Price List See Price List

Shunt Trips

See Price List

R-NZM 7 (110-120V)
R-NZM 7 (220-240V)
R-NZM 7 (24V)
R-NZM 7 (48-60V)

See Price List

110...120
220...240
24
48...60

See Price List

AC/DC
AC/DC
DC
DC

See Price List

Operates the NZM 7 Circuit Breaker or


Molded Case Switch electrically from a
remote location.
Switching Times: ON 100ms, OFF 100ms
Local manual operation of the switch
possible.
Field installable.

See Price List

Remote Control Drive

See Price List See Price List

See Price List

A Molded Case Circuit Breakers and Switches


Undervoltage Trips for Type NZM 7...-N
1

Rated
Actuating
Voltage
(US)

Type suffix

Price

Undervoltage Trips

125 130
208 215

440 480

U-NZM 7 (220-240V AC)


U-NZM 7 (380-415V AC)
U-NZM 7 (440-480V AC)

24

U-NZM 7 (24V DC)

48
110 120

U-NZM 7 (48V DC)


U-NZM 7 (60V DC)
U-NZM 7 (110-120V DC)

125

U-NZM 7 (125-130V DC)

220 240
380 415

DC

60

Undervoltage Trips are field installable.


Ordering information:
Specify Type from column 3.
Example: U-NZM 7 (110-120V AC)
If ordering with device, just specify a + in front of the
Type number.
Example: + U-NZM 7 (110-120V AC)

See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

U-NZM 7 (110-120V AC)


U-NZM 7 (125-130V AC)
U-NZM 7 (208-215V AC)

110 120

See Price List

U-NZM 7 (48V AC)


U-NZM 7 (60V AC)

60

See Price List

48

See Price List

U-NZM 7 (24V AC)

See Price List

D2

24

See Price List

AC

D1
U

See Price List

Undervoltage Trips without Auxiliary Contacts

See Price List

Undelayed response
Undervoltage Trips will electrically trip the device open under power
loss (when supply voltage drops below 35 70% of rated trip coil
value) and can be used for control interlocking purposes e.g. to
disconnect the main switch in Emergency-Stop circuits. They are
rated for continuous duty.
Undervoltage Trips cannot be mounted together with Shunt Trips.

Auxiliary Contacts and Voltage Trips can be combined as follows:


NHI
2 x EK...

RHI
1 x EK...

VHI

AVHI

U(V)HI

Dots in each row represent the types which can be combined together. Dashes indicate
incompatibility.

8/48

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit Breakers and Switches


Undervoltage Trips for Type NZM 7...-NA
1

Rated
Actuating
Voltage
(US)

Type suffix

Price

Undervoltage Trips

24
48
60
110 120
125

UHI-NZM 7 (24V DC)


UHI-NZM 7 (48V DC)
UHI-NZM 7 (60V DC)
UHI-NZM 7 (110-120V DC)
UHI-NZM 7 (125-130V DC)

D2 3.14

Undervoltage Trips are field installable.


Ordering information:
Specify Type from column 3.
Example: UHI-NZM 7 (110-120V AC)
If ordering with device, just specify a + in front of the Type
number.
Example: + UHI-NZM 7 (110-120V AC)

Circuit Breakers
Disconnect Switches, Molded Case Switches

DC

See Price List

UHI-NZM 7 (24V AC)


UHI-NZM 7 (48V AC)
UHI-NZM 7 (60V AC)
UHI-NZM 7 (110-120V AC)
UHI-NZM 7 (125-130V AC)
UHI-NZM 7 (208-215V AC)
UHI-NZM 7 (220-240V AC)
UHI-NZM 7 (380-415V AC)
UHI-NZM 7 (440-480V AC)

See Price List

24
48
60
110 120
125 130
208 215
220 240
380 415
440 480

See Price List

AC

See Price List

3.13

See Price List

D1

See Price List

Undervoltage Trips with Early-Make Auxiliary 1)

See Price List

See Price List

Undelayed response
Undervoltage Trips will electrically trip the device open under power
loss (when supply voltage drops below 35 70% of rated trip coil
value) and can be used for control interlocking purposes e.g. to
disconnect the main switch in Emergency-Stop circuits. They are
rated for continuous duty.
Undervoltage Trips cannot be mounted together with Shunt Trips.

Auxiliary Contacts and Voltage Trips can be combined as follows:


NHI
2 x EK...

RHI
1 x EK...

VHI

AVHI

U(V)HI

Dots in each row represent the types which can be combined together. Dashes indicate
incompatibility.

1) Cannot be used in conjunction with R-NZM 7 Remote Control Drive.

For Immediate Delivery call KMParts.com at (866) 595-9616

8/49

Molded Case Circuit Breakers and Switches


Accessories for Type NZM 7...-NA
1

Type

Price

Notes

H-NZM 7-NA

Red-yellow
For use as an Emergency-Stop Main Disconnect
switch per IEC/EN 60204-1 (CE, Machinery Directive)

RH-NZM 7-NA

Black, without padlocking feature

HOV-NZM 7-NA

Extension shaft
Can be cut to required length
For mounting depths in the range of 175 400 mm

A400-NZM 7

For mounting depths in the range of 260 600 mm

A600-NZM 7

See Price List


See Price List
See Price List
See Price List
See Price List

Black color (Standard)

See Price List

Degree of protection UL/NEMA 12; IEC IP 55


Door coupling rotary handle. For front mounting in
doors and covers.
Door/cover interlocking supplied standard set in OFF position.
3 distinct Handle positions: 0FF - + (tripped) - ON.

See Price List

Handle for Cover/Door Interlocking

See Price List

HU-NZM 7

See Price List

Black color. Rotary Drive Mechanism required.


Fastens to shaft, not padlockable

See Price List

Rotary handle for open or panel mounted switches

See Price List

DA-NZM 7

See Price List

With additional padlocking feature

See Price List

DAOV-NZM 7

See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

Without padlocking feature

See Price List

Converts ON and OFF switching from a toggle


motion to a rotary motion

See Price List

Rotary Drive Mechanism

See Price List

RT-NZM 7

See Price List

Fits around the cutout area of the panel door through


which the toggle mechanism on the front part of the
switch protrudes.

See Price List

Insulating frame for door cutout (IP 40)

See Price List

$
Fastened from the back using screws.
Can be inscribed.

Can be locked in the OFF position with up


to 3 padlocks. Hasp thickness 4 8 mm.

Note: Rotary Drive Mechanism required.

Handles can be locked in the OFF or ON


position with up to 3 padlocks. Hasp
thickness 4 8 mm.
Handle position is fixed when door or cover
is open.

Same features as the H-NZM 7-NA except


that the padlocking feature is omitted.

Ordering information
Specify Type from column 3. Example: H-NZM 7-NA
If ordering with device, just specify a + in front of the Type number. Example: + H-NZM 7-NA.

8/50

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit Breakers and Switches


Accessories for Type NZM 7...-NA
1

Type

Price

Notes

For operation on the right

EA-NZM 7-L
EA-NZM 7-R

With red-yellow rotary handle for use as Emergency-Stop devices


to IEC/EN 60204-1
For operation on the left

EA-RT-NZM 7-L

For operation on the right

EA-RT-NZM 7-R

External warning plate


English text Inscription: Main Switch Open only in OFF position

ZFS 62-NZM 7

Blank

ZFS 60-NZM 7

Other Languages

ZFS...-NZM 7

See Price List


See Price List
See Price List
See Price List

The SWA shifts the rotary movement of the


switch by 90 and permits the rotary handle to
mount and actuate the switch from the side of
the control panel enclosure.
The SWA... mechanism mounts directly on top
of the DA(OV) Rotary Drive Mechanism.
An extension shaft (280 mm) with a special
coupling piece is supplied with the unit.

For mounting the switch directly into the side


panel of the enclosure.
For use only with SWA... side wall operator
equipped switches.
These kits provide the necessary accessories
to fulfill the Main Disconnect switch function
per the Machinery Directive standard IEC 60
204-1.
Note: In cases where the Main Disconnect
switch also fulfills the Emergency-Stop
function, please specify kits containing red
handle and yellow backing plate assemblies.
V... Kits contain:
Door interlocking rotary handle
DAOV rotary drive
Extension shaft for 400 mm mounting depth
External warning plate
Black lightning symbol

EA... Kits contain:


Door coupling rotary handle
DAOV rotary drive
Side wall operator with extension shaft
Mounting brackets
External warning plate
Black lightning symbol

External warning plates available in:


61 German
72 Portuguese
63 French
73 Romanian
64 Bulgarian
74 Russian
65 Danish
75 Swedish
66 Finnish
76 Serbo-Croatia
67 Dutch
77 Spanish
68 Italian
78 Czech
69 Greek
79 Turkish
70 Norwegian
80 Hungarian
71 Polish
81 Afrikaans
To obtain warning plates in other languages,
insert the language code number into the type
reference. Example: External warning plate
in French would be, ZFS 63-NZM 7

Ordering information:
Specify Type from column 3. Example: SWA-NZM 7- L
If ordering with device, just specify a + in front of the Type number. Example: + SWA-NZM 7- L

For Immediate Delivery call KMParts.com at (866) 595-9616

8/51

Circuit Breakers
Disconnect Switches, Molded Case Switches

For operation on the left

See Price List

With black rotary handle

See Price List

For side wall installation

See Price List

V-NZM 7

See Price List

With door interlocking rotary handle. Color: Red-Yellow for


Main Disconnect switches fulfilling the Emergency-Stop function.

See Price List

V-NZM 7-SW

See Price List

With door interlocking rotary handle. Color: Black for standard


Main Disconnect function

See Price List

Main Disconnect Switch Assembly Kits


for CE marked control panels per IEC/EN 60 204-1 (Machinery Directive)

See Price List

MSWA-NZM 7

See Price List

Mounting bracket for side-panel mounting

See Price List

SWA-NZM 7-R

See Price List

For operation on the right

See Price List

SWA-NZM 7-L

See Price List

For operation on the left

See Price List

Enables actuation of the switch from its left or right side


as opposed to the front.

See Price List

Side wall operator

See Price List

Molded Case Circuit Breakers and Switches


Accessories for Type NZM 7...-NA
1

Type

Price

See Price List


See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

For interlocking two Type NZM 7... Circuit Breakers


or Molded Case Switches

For mounting two Type NZM 7... Circuit Breakers or


Molded Case Switches onto a DIN rail conforming to
EN 50 022.
Clip plate not suitable for switches equipped with
R-NZM 7 Remote Control Drives.

See Price List

C-NZM 7

See Price List

Clip plate

KV 2-NZM 7

See Price List

Mechanical interlock

See Price List

Ordering information:
Specify Type from column 3. Example: KV 2-NZM 7
If ordering with device, just specify a + in front of the Type number. Example: + KV 2-NZM 7

8/52

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit Breakers and Switches


Accessories for Type NZM 7...-NA
2

Type

Price

Type

Price

Notes

Ordered with device

See Price List

See Price List

2 Terminals per set.


Control Circuit Wire
Range: AWG 14 18
Cu only.

One piece cover. Fits over


three terminals, top or
bottom.

Circuit Breakers
Disconnect Switches, Molded Case Switches

KA 250-NZM 7

See Price List

See Price List

See Price List

+KA 250-NZM 7

See Price List

For additional protection against shock hazard.


Recommended on the supply side of Circuit Breakers
and Disconnect Switches.
Finger proof to IEC 536

See Price List

Terminal Cover

See Price List

+ST M8-NZM 7-U

See Price List

+ST M8-NZM 7-O

See Price List

For Circuit Breakers and Molded Case Switches


with bolt-on connection terminals.

See Price List

+ST 250-NZM 7-U

See Price List

+ST 250-NZM 7-O

Control Circuit

See Price List

Installed onto the upper and lower field-wiring terminals


of Circuit Breakers and Molded Case Switches.

See Price List

Control circuit Tap-off terminals

See Price List

-O = Mounted on the top


-U = Mounted on the bottom

Ordered separately

See Price List

Ordering information:
Specify Type from column 2 or 4.
Example: + ST-250-NZM 7-U

For Immediate Delivery call KMParts.com at (866) 595-9616

8/53

Molded Case Circuit Breakers and Switches, 600 Amps, 600 VAC
Type NZM 10... Overview

UL / CSA
IEC/EN 60 947 / CE

Circuit Breakers
Disconnect Switches, Molded Case Switches

8
8
9

8/54

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit Breakers and Switches, 600 Amps, 600 VAC
Type NZM 10... Overview
NZM 10
1

Molded Case Breaker Page 8/58 60


600 VAC, 600 Amp rating
Up to 100 kA @ 480 VAC Interrupting rating
Standard and fuseless current limiting versions
Solid State Trip
Field installable accessories
Supplied with terminals for cable hookup or
bolt-on connection
UL Listed (UL 489), CSA certified (C 22.2 # 5.1)
Conformity with IEC/EN 60 947-2 (Circuit Breakers)

Remote Control Drive Page 8/67


Electrical operation of the circuit breaker from a remote
location:
Remote ON/OFF
Remote Reset after Trip
Local manual operation possible
Padlockable OFF position

Rotary Handle Page 8/68


To operate switch equipped with rotary drive mechanism.

Molded Case Switch Page 8/61


600 VAC, 600 Amp rating
Field installable accessories
UL Listed (UL 1087), CSA certified (C 22.2 # 5.2)
Conformity with IEC/EN 60 947-3 (Switch-Disconnectors)

Auxiliary Contacts Page 8/64

Converts toggle switch operation of the switch into a rotary


movement suitable for rotary style operators.
Lockable in the OFF position.

Auxiliary Contacts & Voltage Trips Page 8/64 66


Type VHI... Early-Make auxiliary contact:
For interlocking and load shedding purposes.
To power up the undervoltage trip prior to main contact closing
Voltage Trips:
Shunt Trips
AC & DC versions
Undervoltage Trips
AC & DC versions

Ground Fault Trip Module Page 8/67


Plugs directly into the breaker or mounts separately.
Not fed from separate power source.
Adjustable ground fault trip and time delay settings.
Automatic Reset.

Type NHI... standard auxiliary contact:


For signalling ON and OFF positions
Type RHI... trip-indicating auxiliary contact:
For signalling the Tripped (+) position

Rotary Drive Mechanism Page 8/68

Signalling Block Page 8/64


Differentiated fault indication
Overload early warning signal for load shedding purposes
Local or remote signalling of breaker status
Local, remote or automatic reset.

Terminal Connections Page 8/


Pressure wire terminations for cable connection.
Bolt-on connection for crimped lug or busbar.
Terminal covers for additional protection against
shock hazards.

For Immediate Delivery call KMParts.com at (866) 595-9616

Circuit Breakers
Disconnect Switches, Molded Case Switches

8/55

Molded Case Circuit Breakers and Switches


Type NZM 10... Overview of Combination Options
Type

Solid State
Trip Modules

Solid State
Trip Modules
with pick-up
delay for selectivity

Auxiliary contacts
(NHI...: Standard)
(RHI...: Trip Indicating)
(VHI...: Early-Make)

Signalling
Block

ZM(A)-...-NA
250 400 600

ZMV(A)-...-NA
250 400 600

NHIRHIVHI-NZM 10
NZM 10 NZM 10 Not in conjunction with
R-NZM 10

MNZM 10

Molded Case Circuit Breakers


NZM 10-...(N)(S)/ZM(V)(A)...-NA

or

NZM 10-...H/ZM(A)...-NA

Circuit Breakers
Disconnect Switches, Molded Case Switches

Molded Case Switches


NZM 10-...N/B-NA

Circuit Breakers equipped with Remote Control


Drive
or

NZM 10-...(N)(S)/ZM(V)(A)...-NA
+R-NZM 10

NZM 10-...H/ZM(A)...-NA
+ R-NZM 10

With
ZM(V)

Molded Case Switches equipped with Remote


Control Drive
NZM 10-...N/B-NA
+R-NZM 10

Circuit Breaker Switch blocks without Trip


Modules
NZM 10-400N-NA
NZM 10-400S-NA
NZM 10-400H-NA
NZM 10-600N-NA
NZM 10-600S-NA
NZM 10-600H-NA

8/56

Options for combination


Included as standard

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit Breakers and Switches


Type NZM 10... Overview of Combination Options

ANZM 10

Terminals
Bolt connection included as standard

UNZM 10

TVNZM 10

RNZM 10

DNZM 10

H 10UNZM 10

(R)H 10NZM 10

Bolt-on
connection

Cable
Terminals

or

or

or

or

or

or

or

or

or

or

or

or

or

or

or

or

or

or

or
or
or
or
or
or

or
or
or
or
or
or

or
or
or
or
or
or

or
or
or
or
or
or

or
or
or
or
or
or

For Immediate Delivery call KMParts.com at (866) 595-9616

Circuit Breakers
Disconnect Switches, Molded Case Switches

Voltage Trips
Ground-Fault Remote
Rotary Drive Mechanism
Trip
Control
Rotary
Handle
(A...: Shunt Trip)
Drive
Door coupling rotary handle
(U...: Undervoltage Trip)

8/57

Inverse Time Circuit Breakers, 600 Amps, 600V AC


Solid State Trip, Type NZM 10...-NA
4

Adjustable
instantaneous
Pick-up
Setting

Adjustable
Short Time Delay
Pick-up setting
for selectivity in
networks

Type

Price

Amps

Adjustable Long Time response settings for Type NZM 10-... N/ZM-...-NA
200 400
300 600

400 4800
600 7200

NZM 10-400 N/ZM-400-NA


NZM 10-600 N/ZM-600-NA

Fixed Long Time response settings for Type NZM 10-.../ZMVA-...-NA


with Short-Time Delay pick-up for Selectivity
200
225
250
300
350
400
500
600

1000 9000
1000 9000
1000 9000
1000 9000
1000 9000
1000 9000
1000 9000
1000 9000

2 12 x Ir
2 12 x Ir
2 12 x Ir
2 12 x Ir
2 12 x Ir
2 12 x Ir
2 12 x Ir
2 12 x Ir

NZM 10-400 N/ZMVA-200-NA


NZM 10-400 N/ZMVA-225-NA
NZM 10-400 N/ZMVA-250-NA
NZM 10-400 N/ZMVA-300-NA
NZM 10-400 N/ZMVA-350-NA
NZM 10-400 N/ZMVA-400-NA
NZM 10-600 N/ZMVA-500-NA
NZM 10-600 N/ZMVA-600-NA

Adjustable Long Time response settings for Type NZM 10-.../ZMV-...-NA


with Short-Time Delay pick-up for Selectivity
200 400
300 600

1000 9000
1000 9000

400 4800
600 7200

NZM 10-400 N/ZMV-400-NA


NZM 10-600 N/ZMV-600-NA

See Price List

NZM 10-400 N/ZMA-200-NA


NZM 10-400 N/ZMA-225-NA
NZM 10-400 N/ZMA-250-NA
NZM 10-400 N/ZMA-300-NA
NZM 10-400 N/ZMA-350-NA
NZM 10-400 N/ZMA-400-NA
NZM 10-600 N/ZMA-500-NA
NZM 10-600 N/ZMA-600-NA

See Price List

See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

400 2400
450 2700
500 3000
600 3600
700 4200
800 4800
1000 6000
1200 7200

See Price List

(600A)

200
225
250
300
350
400
500
600

See Price List

Fixed Long Time response settings for Type NZM 10-... N/ZMA-...-NA

See Price List

$
See Price List

Amps

42 kA @ 480 VAC

See Price List

Amps

Time delay Range:


0 1000 ms

See Price List

(Ir)

(N) Normal Level


Interrupting:

See Price List

Long Time
Response
Current
Setting

See Price List

See Price List

UL/CSA, IEC/EN 60 947-2, CE

Type NZM 10-...(N)(S)/ZM(A)-...-NA Molded Case Circuit Breakers are UL Listed (UL 489) and CSA Certified (22.2 Nr. 5.1) Inverse Time, Solid State
Trip Circuit Breakers with a fixed or adjustable Long Time Response and adjustable instantaneous pick-up range.
Type NZM 10-...(N)(S)/ZMV(A)-...-NA are UL Listed (UL 489) and CSA Certified (22.2 Nr. 5.1) and have an additional short time delay pick-up range
for selectivity in energy distribution networks. The time delay response is adjustable from 0 to 1000 milliseconds.
Type NZM 10-...H/ZM(A)-...-NA Molded Case Circuit Breakers are UL Listed (UL 489) and CSA Certified (22.2 Nr. 5.1)
Current Limiting Inverse Time, Solid State Trip Circuit Breakers with a fixed or adjustable Long Time Response and adjustable instantaneous pick-up
range.

Ordering Information:
State type from Column 5, 7 or 9. Example: NZM 10-600 H/ZMA-500-NA.
Note:
- NZM 10 Circuit Breakers and Molded Case Switches are supplied with toggle operator. Consult page 8/68 for additional handle types.
- Consult pages 8/62 71 for additional accessories.
- NZM 10 Circuit Breakers and Molded Case Switches are supplied standard with bolt-on connection. For Line and Load field-wiring terminals for
cable connection, refer to page 8/70 71 for details on available terminals.

8/58

For Immediate Delivery call KMParts.com at (866) 595-9616

UL/CSA, IEC/EN 60 947-2, CE

Inverse Time Circuit Breakers, 600 Amps, 600 VAC


Solid State Trip, Type NZM 10...-NA

10

Type

Price

Type

Price

(S) Super Level


Interrupting:

(H) Highest Level


Interrupting:

65 kA @ 480 VAC

Fuseless Current Limiting


Circuit Breaker
100 kA @ 480 VAC
$

UL/CSA Interrupting ratings


(AC, 60Hz)
Type

Circuit Breakers
Disconnect Switches, Molded Case Switches

See Price List


See Price List
See Price List
See Price List

See Price List


See Price List
See Price List

See Price List

See Price List

See Price List

NZM 10-400 H/ZM-400-NA


NZM 10-600 H/ZM-600-NA

See Price List

NZM 10-400 H/ZMA-200-NA


NZM 10-400 H/ZMA-225-NA
NZM 10-400 H/ZMA-250-NA
NZM 10-400 H/ZMA-300-NA
NZM 10-400 H/ZMA-350-NA
NZM 10-400 H/ZMA-400-NA
NZM 10-600 H/ZMA-500-NA
NZM 10-600 H/ZMA-600-NA

See Price List

See Price List


See Price List
See Price List
See Price List
See Price List

See Price List


See Price List
See Price List

See Price List

NZM 10-400 S/ZMV-400-NA


NZM 10-600 S/ZMV-600-NA

See Price List

NZM 10-400 S/ZMVA-200-NA


NZM 10-400 S/ZMVA-225-NA
NZM 10-400 S/ZMVA-250-NA
NZM 10-400 S/ZMVA-300-NA
NZM 10-400 S/ZMVA-350-NA
NZM 10-400 S/ZMVA-400-NA
NZM 10-600 S/ZMVA-500-NA
NZM 10-600 S/ZMVA-600-NA

See Price List

NZM 10-400 S/ZM-400-NA


NZM 10-600 S/ZM-600-NA

See Price List

NZM 10-400 S/ZMA-200-NA


NZM 10-400 S/ZMA-225-NA
NZM 10-400 S/ZMA-250-NA
NZM 10-400 S/ZMA-300-NA
NZM 10-400 S/ZMA-350-NA
NZM 10-400 S/ZMA-400-NA
NZM 10-600 S/ZMA-500-NA
NZM 10-600 S/ZMA-600-NA

11

3
3
3

Accessories

Page

1
2
3
4

8/64
8/65, 66
8/69
8/71

Auxiliary contacts
Voltage Trips
Handles and operators
Terminals

Features of ZMV(A)...Trip Modules used for Selectivity:


RMS Sym kAmps @
240 V

NZM 10-... N/ ZM(V)(A)-...-NA 65


NZM 10-... S/ ZM(V)(A)-...-NA 100
NZM 10-... H/ ZM(A)-...-NA
200

480 V

600 V

42
65
100

35
42
50

Fixed (ZMVA...) or adjustable (ZMV...) long time response current.


Adjustable time delay (2 20 sec.) for current levels at 6 x the long
time response current (Ir).
Long time response current can be disconnected.
Adjustable time delay (0 1000 ms) pick-up setting.
Adjustable instantaneous pick-up response.

For Immediate Delivery call KMParts.com at (866) 595-9616

8/59

Molded Case Circuit Breakers - Instantaneous Trip type, 600 Amp


NZM 10-.../ZM-...-OBI...-CNA
2

Continuous
Current
Rating

Adjustable
Instantaneous Trip
Response
Range

Type

Price

Amps
Solid State Instantaneous Trip Circuit Breakers
600 V AC, UL/CSA
(N) Normal Level Short circuit Rating

Circuit Breakers
Disconnect Switches, Molded Case Switches

Amps

400

800...4800

NZM 10-400 N/ZM -400-OBI-CNA

600

1200...7200

NZM 10-600 N/ZM -600-OBI-CNA

400

800...4800

NZM 10-400 H/ZM -400-OBI-CNA

600

1200...7200

NZM 10-600 H/ZM -600-OBI-CNA

NZM 10-...N/ZM-...-OBI-CNA
(600 Amps)
Solid State Instantaneous Trip Circuit Breakers
600 V AC, UL/CSA
(H) High Level Short circuit Rating

NZM 10-...N/ZM-...-OBI-CNA
(600 Amps)

See Price List See Price List See Price List See Price List See Price List See Price List

Frame
Rating

See Price List See Price List See Price List See Price List See Price List See Price List

Type NZM10-...N/ZM-...-OBI...-CNA and NZM10-...H/ZM-...-OBI...-CNA Molded Case Circuit Breakers are UL Recognized (UL 489) and CSA
Certified (22.2 Nr. 5.1) Instantaneous Trip type Circuit Breakers with an adjustable instantaneous trip function.
Per NEC, they provide motor short circuit protection as part of a listed combination motor controller that includes coordinated motor overload
protection. Short circuit interrupting ratings are, therefore, established and valid only for the listed combination motor controller assembly and
associated housing or enclosure.
The NZM 10...H instantaneous trip circuit breaker features a current limiting design contact assembly and can provide high fault short circuit current
ratings for motor starters of up to 65kA @ 480VAC.
Consult Moeller Electric for Combination Motor Controller high fault short circuit ratings as Motor Control Center unit starters featuring Type
NZM10...N and NZM10...H Instantaneous Trip Circuit Breakers.

Ordering Information:
State type from Column 4. Example: NZM 10-600 H/ZM-600-OBI-CNA
Note:
- NZM 10 Circuit Breakers and Molded Case Switches are supplied with toggle operator. Consult page 8/69 for additional handle types.
- Consult page 8/67 for additional accessories.
- NZM 10 Circuit Breakers and Molded Case Switches are supplied standard with bolt-on connection. For Line and Load field-wiring terminals
for cable connection, refer to page 8/71 for details on available terminals.

8/60

For Immediate Delivery call KMParts.com at (866) 595-9616

UL/CSA, IEC/EN 60 947-3, CE

Type

Price

Notes

NZM 10-400 N/B-NA

600

NZM 10-600 N/B-NA

See Price List

See Price List

See Price List

See Price List

See Price List

400

UL/CSA
Short Circuit Current Rating:
25 kA RMS Sym @ 600 VAC

Type NZM 10-...N/B-NA Molded Case Switches are virtually identical in construction to NZM 10 Molded Case Circuit Breakers except that they are
manual, non-automatic switches without any overload or overcurrent protective features. They are equally rated up to 600 Amps.
All Molded Case Switches are UL Listed (UL 1087)/ CSA certified (C 22.2 Nr. 5.2), in conformity with IEC/EN 60 947-3 (Switch-Disconnectors) and
CE marked.
Molded Case Switches are tested to determine their acceptability for continuous operation at their marked rated load. In addition, they are tested at
six times their full ampere rating to cover motor circuit applications and are suitable for use as motor circuit disconnects per Section 430-109 of the
National Electrical Code.
Accessories such as voltage trips, auxiliary contacts, rotary handles etc. are common to all NZM 10 circuit breakers and molded case switches and
are UL listed and CSA certified for field installation.

Ordering Information:
Specify Type from Column 3. Example: NZM 10-400 N/B-NA.
Note:
- NZM 10 Circuit Breakers and Molded Case Switches are supplied with toggle operator. Consult page 8/69 for additional handle types.
- Consult page 8/67 for additional accessories.
- NZM 10 Circuit Breakers and Molded Case Switches are supplied standard with bolt-on connection. For Line and Load field-wiring terminals
for cable connection, refer to page 8/71 for details on available terminals.

For Immediate Delivery call KMParts.com at (866) 595-9616

8/61

Circuit Breakers
Disconnect Switches, Molded Case Switches

With provisions for bolt-on connection

See Price List

Molded Case Switches

See Price List

Amps

See Price List

Ampere
Rating

See Price List

See Price List

Molded Case Switches, 600 Amps, 600 VAC


Type NZM 10...-NA

Inverse Time Circuit Breaker Components, 600 Amps, 600VAC


Type NZM 10...-NA Switch Blocks, Solid State Trip Modules
1

The NZM 10 Inverse Time Molded Case


Breaker is made up of a Switch Block and
a protective Trip Module.
Switch Blocks and Trip Modules can be
ordered separately and combined per the
charts and columns shown here to suit
any particular application.
Refer to chart at bottom of page for
resultant interrupting ratings.

Switch Block
Ratings

Trip Module Ratings

Continuous
Current
(Iu)

Long Time
Response
Current
Setting
(Ir)

Adjustable
instantaneous
Pick-up
Setting

UL/CSA, IEC/EN 60 947-2, CE

Adjustable
Short Time Delay
Pick-up setting
for selectivity in
networks
Time delay range:
0 1000 ms

Compatibility of Switch Block


with Trip Module
Dots () in each row indicate
which Trip Module (Refer to
column 7) can be used with the
Switch Block type shown below.
Dashes ( )indicate incompatibility.

Amps

Amps

Amps

NZM10-400...

NZM10-600...

Fixed Long Time Response

200
225
250
300
350
400
500
600

400 2400
450 2700
500 3000
600 3600
700 4200
800 4800
1000 6000
1200 7200

Adjustable Long Time Response

200 400
300 600

400 4800
600 7200

Fixed Long Time Response

200
225
250
300
350
400
500
600

1000 9000
1000 9000
1000 9000
1000 9000
1000 9000
1000 9000
1000 9000
1000 9000

2 12 x Ir
2 12 x Ir
2 12 x Ir
2 12 x Ir
2 12 x Ir
2 12 x Ir
2 12 x Ir
2 12 x Ir

Adjustable Long Time Response

200...400
300...600

1000...9000
1000...9000

400...4800
600...7200

Amps
Switch Blocks, Suitable for insertion of Trip Modules

Circuit Breakers
Disconnect Switches, Molded Case Switches

400
400
400
600
600
600
Solid State Trip Modules

Solid State Trip Modules for Selectivity in networks

UL/CSA Interrupting ratings


(AC, 60Hz)
Type

RMS Sym kA @
240 V 480 V 600 V

NZM 10-... N/ ZM(V)(A)-...-NA


NZM 10-... S/ ZM(V)(A)-...-NA
NZM 10-... H/ ZM(A)-...-NA

65
100
200

8/62

42
65
100

35
42
50

Type NZM 10... Molded Case Circuit Breakers can be ordered complete
(consult p. 8/58,59), or assembled from components by combining Switch Blocks
and protective Trip Modules.
Example: NZM10-600N-NA (Switch Block) +ZMA-500-NZM 10-NA (Trip Module)
= NZM 10-600 N/ZMA-500-NA Molded Case Circuit Breaker

For Immediate Delivery call KMParts.com at (866) 595-9616

UL/CSA, IEC/EN 60 947-2, CE


7

Type

Price

Notes

Inverse Time Circuit Breaker Components, 600 Amps, 600VAC


Type NZM 10...-NA Switch Blocks, Solid State Trip Modules
10

NZM 10 Switch Blocks make up a complete breaker


minus the protective Trip Module.
Add a Trip Module from below to complete the
breaker assembly. Refer to Column 6 for
compatibility information on Switch Blocks and Trip
Modules.
Refer to chart at bottom of opposite page for
resultant circuit breaker interrupting ratings.

ZMA solid state trip modules have a fixed long time


response and an adjustable instantaneous pick-up
range.
3
3
3

ZM solid state trip modules have an adjustable long


time response and an adjustable instantaneous
pick-up range.

Accessories

Page

1
2
3
4

8/64
8/65, 66
8/69
8/71

Auxiliary contacts
Voltage Trips
Handles and operators
Terminals

Features of ZMV(A)... Trip Modules used for


Selectivity:
Fixed (ZMVA...) or adjustable (ZMV...) long time
response current.
Adjustable time delay (2 20 sec.) for current levels
at 6 x the long time response current (Ir).
Long time response current can be disconnected.
Adjustable time delay (0 1000 ms) pick-up setting.
Adjustable instantaneous pick-up response.
Note: ZMVA... and ZMV Trip Modules cannot be
combined with NZM 10-400 H-NA and
NZM 10-600 H-NA Switch Blocks.

Ordering Information: Specify Type from column 7. Example: NZM 10-600 N-NA
Note:
- Compatible Trip Modules will easily fit into the front part of the switch block. Incompatible Trip Modules and Switch Block combinations are
mechanically blocked to prevent creation of improper combinations. (Refer to columns 6 & 7)
- NZM 10 Switch Blocks are supplied with toggle operator. Consult page 8/69 for additional handle types.
- Consult page 8/67 for additional accessories.
- NZM 10 Circuit Breakers and Molded Case Switches are supplied standard with bolt-on connection. For Line and Load field-wiring terminals
for cable connection, refer to page 8/71 for details on available terminals.

For Immediate Delivery call KMParts.com at (866) 595-9616

8/63

Circuit Breakers
Disconnect Switches, Molded Case Switches

See Price List


See Price List
See Price List
See Price List
See Price List

See Price List

See Price List


See Price List

See Price List

ZMV-400-NZM 10-NA
ZMV-600-NZM 10-NA

See Price List

ZMVA-200-NZM 10-NA
ZMVA-225-NZM 10-NA
ZMVA-250-NZM 10-NA
ZMVA-300-NZM 10-NA
ZMVA-350-NZM 10-NA
ZMVA-400-NZM 10-NA
ZMVA-500-NZM 10-NA
ZMVA-600-NZM 10-NA

See Price List

ZM-400-NZM 10-NA
ZM-600-NZM 10-NA

See Price List

ZMA-200-NZM 10-NA
ZMA-225-NZM 10-NA
ZMA-250-NZM 10-NA
ZMA-300-NZM 10-NA
ZMA-350-NZM 10-NA
ZMA-400-NZM 10-NA
ZMA-500-NZM 10-NA
ZMA-600-NZM 10-NA

See Price List

NZM 10-400N-NA
NZM 10-400S-NA
NZM 10-400H-NA
NZM 10-600N-NA
NZM 10-600S-NA
NZM 10-600H-NA

See Price List

Molded Case Circuit Breakers and Switches


Auxiliary Contacts, Signalling Unit for Type NZM 10...-NA
1

Contact sequence

Type

Price

NHI standard auxiliary contacts


Switching simultaneously with the main contacts. They can be typically
used for signalling, interlocking or switching auxiliary circuits such
as a control circuit.

NHI-NZM 10

1.13 1.21 1.43 1.31

1.14 1.22 1.44 1.32

VHI Early-Make auxiliary contacts


Typically used for powering up the undervoltage trip prior to closing
of main contacts and for control circuit interlocking tasks.
Cannot be used in conjunction with R-NZM 10 Remote Control Drive

Circuit Breakers
Disconnect Switches, Molded Case Switches

RHI trip-indicating auxiliary contacts


Actuating independently of the normal ON and OFF operations of
the device, switching only when the device has tripped due to
overcurrents or other tripping causes such as those initiated by
voltage trips.

VHI-NZM 10

3.13 3.33 3.21

3.14 3.34 3.22

RHI-NZM 10

4.13 4.21 4.43 4.31

4.14 4.22 4.44 4.32

Signalling Block
Differential fault indication and visual display of breaker operating
states

Mounts directly onto lower portion of circuit-breaker


Supply voltage necessary:
24 230 V, AC or DC

(2)

(3)

N.O. N.C.

N.O. N.C.

5.53 5.61 5.33 5.41 5.13 5.21

5.54 5.62 5.34 5.42 5.14 5.22

100 % Ir

M-NZM 10

Each function signals via a pair of contacts (1 N.O. & 1 N.C.)

N.C.

}
}

(1) Tripping due to short-circuit.


(2) Tripping due to overload and general trip condition.
(3) Overload early warning signal in the event that the long time
response setting is about to be exceeded (i.e. useful for load
shedding purposes)

(1)
N.O.

I>

Auxiliary Contacts and Signalling Blocks are field installable.

Ordering information:
Specify Type from column 3.
Example: NHI-NZM 10
If ordering with device, just specify a + in front of the Type number. Example: + NHI-NZM 10

8/64

For Immediate Delivery call KMParts.com at (866) 595-9616

See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List

Auxiliary Contacts

See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List

Molded Case Circuit Breakers and Switches


Shunt Trips for Type NZM 10...-NA
2

Rated Actuating
Voltage
(US)

Type

Price

AC/DC 24

A-NZM 10 (24V)

48

A-NZM 10 (48V)

60

A-NZM 10 (60V)

110 120

A-NZM 10 (110-120V)

125 130

A-NZM 10 (125-130V)

208 215

A-NZM 10 (208-215V)

220 240

A-NZM 10 (220-240V)

380 415

A-NZM 10 (380-415V)

440 480

A-NZM 10 (440-480V)

500

A-NZM 10 (500V)

600

A-NZM 10 (600V)

Field installable and suitable for mounting


into NZM 10 Molded Case Circuit Breakers and Switches.
Shunt Trips are rated for both AC and DC
voltages and can accommodate a frequency range between 0 and 400 Hz.

Circuit Breakers
Disconnect Switches, Molded Case Switches

See Price List


See Price List
See Price List
See Price List
See Price List

C2

See Price List

C1

See Price List

Shunt Trips are typically used to electrically trip


the device from a remote location.
The A...- NZM 10 series is rated for 100%
continuous duty. Shunt Trips cannot be
mounted together with Undervoltage Trips.

See Price List

Shunt Trips

See Price List

$
each

See Price List

Shunt trips are field installable.

Ordering information:
Specify Type from column 3.
Example: A-NZM 10 (110-120V)
If ordering with device, just specify a + in front of the Type number.
Example: + A-NZM 10 (110-120V)

For Immediate Delivery call KMParts.com at (866) 595-9616

8/65

Molded Case Circuit Breakers and Switches


Undervoltage Trips and Ground Fault Trip Module for Type NZM 10...-NA
1

Rated Actuating
Voltage
(US)

Type

Price

Attached directly to the breaker or mounted separately

In
6.14 6.22

Ground Fault Trip Module is attached to the circuit-breaker:


Ground fault trip current is signalled directly to the breaker electronic
circuitry.

TV-NZM 10

Ground Fault Trip Module is mounted separately:


Ground fault trip current is signalled directly to a shunt or undervoltage
trip via auxiliary contacts 6.13 6.14 or 6.21 6.22

TV-NZM 10/E

Accessories are field installable.

Ordering information:
Specify Type from column 3.
Example: U-NZM 10 (110-120V)
If ordering with device, just specify a + in front of the Type number.
Example: + U-NZM 10 (110-120V)

8/66

For Immediate Delivery call KMParts.com at (866) 595-9616

See Price List


See Price List
See Price List
See Price List

6.13 6.21

See Price List

See Price List

No outside power source necessary, ground fault trip current adjustable in


steps:
In = 80, 100,130, 160, 200, 240, 280, 320, 360, 400 A
With an adjustable delay time:
tv = 0, 60, 150, 200, 300, 500, 750, 1000 ms

See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

Ground Fault Trip Module

See Price List

U-NZM 10 (24V DC)


U-NZM 10 (48V DC)
U-NZM 10 (60V DC)
U-NZM 10 (110-120V DC)
U-NZM 10 (125-130V DC)
U-NZM 10 (208-215V DC)
U-NZM 10 (220-240V DC)

See Price List

24
48
60
110 120
125 130
208 215
220 240

See Price List

DC

D2

See Price List

U-NZM 10 (24V AC)


U-NZM 10 (48V AC)
U-NZM 10 (60V AC)
U-NZM 10 (110-120V AC)
U-NZM 10 (125-130V AC)
U-NZM 10 (208-215V AC)
U-NZM 10 (220-240V AC)
U-NZM 10 (380-415V AC)
U-NZM 10 (440-480V AC)
U-NZM 10 (500V AC)
U-NZM 10 (600V AC)

See Price List

24
48
60
110 120
125 130
208 215
220 240
380 415
440 480
500
600

See Price List

AC

See Price List

D1
U

See Price List

Undelayed response
Undervoltage Trips will electrically trip the device open under power loss
(when supply voltage drops below 35 70% of rated trip coil value) and
can be used for control interlocking purposes e.g. to disconnect the main
switch in Emergency-Stop circuits. They are rated for continuous duty.
Undervoltage Trips cannot be mounted together with Shunt Trips.

See Price List

Undervoltage Trips

See Price List

See Price List

Type NZM 10...-NA Molded Case Circuit Breakers and Switches


Remote Control Drives and Accessories
2

Contact diagram

Rated
Actuating
Voltage
(US)
50/60 Hz

Type

Price

For both Circuit Breakers and Molded Case Switches


Switching times: ON 60 ms, OFF 30 ms
Manual switching possible

L1(L+)
0

70

H1

R-NZM 10
74

70

75

70

71 72

R-NZM 10
74

H1

RHI

H1

71 72

110 120 AC R-NZM 10 (110-120V AC)

L1(L+)

L1(L+)
0
S

R-NZM 10
74

75

75

N(L-, L2)

N(L-, L2)

N(L-, L2)

3-wire control

2-wire control

3-wire control with


automatic reset to the
OFF position after the
switch has tripped.

Mounts on top of NZM 10 Circuit Breakers and


Molded Case Switches

220 240 AC R-NZM 10 (220-240V AC)

71 72

380 415 AC R-NZM 10 (380-415V AC)


24

DC R-NZM 10 (24V DC)

48 60

DC R-NZM 10 (48-60V DC)

100 130 DC R-NZM 10 (100-130V DC)


220 240 DC R-NZM 10 (220-240V DC)

Pushbutton operator
For manual ON-OFF switching of encapsulated NZM 10 breakers and switches equipped with
a remote control drive. Not for use in conjunction with KVR2-NZM 10 mechanical interlock.

Mounting depth 250 285 mm

MD-NZM 10

Mounting depth 285 400 mm

MDV-NZM 10

IP 54 Protective cover for door cutout area


Transparent cover to provide a panel cutout area with IP 54 protection
For use where the Remote Control Drive protrudes from the cutout area
of the enclosure door.

RTR-NZM 10

Sealing plate
To block off manual switching access of the remote control drive at the device.
Electrical switching from a remote location and manual tripping of the circuit breaker
(push to trip feature) are not affected.

PL-NZM 10

Ordering information: Specify Type from column 4. Example: R-NZM 10 (110-120V AC)
If ordering with device, just specify a + in front of the Type number.
Example: + R-NZM 10 (110-120V AC)

For Immediate Delivery call KMParts.com at (866) 595-9616

8/67

Circuit Breakers
Disconnect Switches, Molded Case Switches

Remote Control Drive

See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List

$
See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List

Molded Case Circuit Breakers and Switches


Accessories for Type NZM 10...-NA
1

Type

Price

Notes

SVB-NZM 10

Insulating cutout frame


RT-NZM 10

Circuit Breakers
Disconnect Switches, Molded Case Switches

Rotary Drive Mechanism


D-NZM 10

Rotary Handle, for open or panel mounted devices


H10U-SW

Extension shaft

For mounting depths 175 400 mm

A-NZM 10

For mounting depths 260 600 mm

A600-NZM 10

Maintenance Handle
To actuate the device when the panel door is open.

For Type A-NZM 10 Extension shafts

H10UZ

For Type A600-NZM 10 Extension shafts

H12UZ

See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List

Toggle switch interlock

See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List

Permits the OFF position of the


toggle operator to be locked with up
to 3 padlocks (hasp thickness 6 8
mm)
For use where the toggle switch
protrudes from the enclosure.
Provides degree of protection
IP 40. Affixed from the rear with
screws. Can be inscribed.

Converts ON and OFF switching


from a vertical toggle movement to a
rotary motion.
Required for the use of rotary and
door coupling/interlocking rotary
handles. Can be locked in the OFF
position with up to 3 padlocks. Hasp
thickness, 4 8 mm.

Black color. Suitable for open mount


switches. No door interlocking or
padlocking provisions. Requires
Rotary Drive mechanism.

Can be cut to required length.

For panel mounted switches


Push-fits onto the extension shaft

Ordering information:
Specify Type from column 2. Example: D-NZM 10
If ordering with device, just specify a + in front of the Type number.
Example: + D-NZM 10

8/68

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit Breakers and Switches


Type NZM 10...-NA Accessories
1

Type

Price

Black color: For standard Main Disconnect Switch applications

H 10-SW-NA

Red-yellow color:
Enables the switch to be used as the Emergency-Stop Disconnect

RH 10-NA

Switch position indicator


Indicates position of switch (OFF, tripped or ON) when panel door is open.

SA-NZM 10

Main Disconnect Switch Assembly Kits


for CE marked control panels per IEC/EN 60 204-1
Type NZM 10-...-NA breakers and switches have dual UL/CSA and IEC/EN
ratings. They are suitable for use as Main Disconnect Switches in control panels
that must be CE marked and designed to comply with the Machinery Directive
standard EN 60 204-1.
Kit includes:
Door interlocking rotary handle, color Black
Rotary Drive Mechanism
Extension shaft for 400 mm mounting depth
External warning plate
Black lightning symbol
Same as above, but with red-yellow door interlocking rotary handle.
For use when Main Disconnect also fulfills Emergency-Stop function per
IEC/EN 60204-1
Main Disconnect Warning plates
English Inscription: Main Switch Open only in OFF position

V-NZM 10-SW

V-NZM 10

ZS 62-NZM 10

Warning plates also available in other languages:


61 German
63 French
64 Bulgarian
65 Danish
66 Finnish

67 Dutch
68 Italian
69 Greek
70 Norwegian
71 Polish

72 Portuguese 77 Spanish
73 Romanian
78 Czech
74 Russian
79 Turkish
75 Swedish
80 Hungarian
76 Serbo-Croatia 81 Afrikaans

To obtain warning plates in other languages, insert the language code number
into the type reference.
Example: External warning plate in Spanish would be: ZS 77-NZM 10

ZS..-NZM 10

Blank plate (for engraving or printing)

ZS 60-NZM 10

Ordering information:
Specify Type from column 3.
Example: H 10-SW-NA
If ordering with device, just specify a + in front of the Type number.
Example: + H 10-SW-NA

For Immediate Delivery call KMParts.com at (866) 595-9616

8/69

Circuit Breakers
Disconnect Switches, Molded Case Switches

Degree of protection UL/NEMA 3R/12; IEC IP 55


With cover interlocking and padlocking feature
Rotary Drive Mechanism required.
Can be locked in the OFF or ON position with up to 3 padlocks
3 distinct Handle positions: OFF- +(tripped)- ON

See Price List See List Price See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List

Handle for Cover/Door Interlocking

See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List

Molded Case Circuit Breakers and Switches


Accessories for Type NZM 10...-NA
1

Type

Price

Incomer 2

0 = OFF
V = Interlocked
1 = ON

Ordering information:
Specify Type from column 3.
Example: KV2-NZM 10

8/70

For Immediate Delivery call KMParts.com at (866) 595-9616

See Price List


See Price List
See Price List

Emergency

See Price List

KVA3-NZM 10

Incomer 1

See Price List

Possible switching positions:

See Price List

For emergency power supplies:


Mechanically interlocking two incoming supply circuit breakers with one emergency supply
breaker. Fits toggle operators or rotary drive mechanisms.

See Price List

See Price List

KV3-NZM 10

See Price List

KVR2-NZM 10

See Price List

Circuit Breakers
Disconnect Switches, Molded Case Switches

For mechanically interlocking three NZM 10 Circuit Breakers or Molded Case Switches
mounted in a panel.
Fits toggle operators or rotary drive mechanisms

KV2-NZM 10

See List Price

For two circuit-breakers equipped with R-NZM 10 Remote Control


Drives. (R-NZM 10 must be electrically interlocked at the
same time)

See Price List

For two circuit breakers

See Price List

For mechanically interlocking two NZM 10 Circuit Breakers or Molded Case Switches
mounted in a panel.
Fits toggle operators or rotary drive mechanisms

See Price List

See Price List

Mechanical interlocks

See Price List

Molded Case Circuit Breakers and Switches


Terminals for Type NZM 10...-NA
5
1)

Type suffix
Price
Sets of three terminals
ordered with breaker or
molded case switch:
O = Mounted on Top
U = Mounted on Bottom $

Terminals

2 x AWG 2 500 kcmil


Cu/Al

+ K2X240IP-NZM 10-O

600

2 x AWG 2 500 kcmil


Cu/Al

Supplied with 1 terminal cover


(Type H-NZM 10)

600

2 x AWG 2 500 kcmil


Cu/Al

Single cable clamp terminal.


Not supplied with terminal
cover. Suitable terminal cover
is Type HH-NZM 10

350

250 500 kcmil


Cu only

+ K300-NZM 10-O

Double cable clamp terminal.


Not supplied with cover.
Suitable terminal cover is
Type HH-NZM 10

500

2 x AWG 3/0 250 kcmil


Cu only

+K2x120-NZM 10-O

Supplied with 3 terminal


covers (Type H-NZM 10) and
an insulating plate onto which
the circuit breaker is mounted.

600

Supplied with 1 terminal cover


(Type H-NZM 10) and an
insulating plate onto which the
circuit breaker is mounted.

+ K2X240IP-NZM 10-U

+ K300-NZM 10-U

+K2x120-NZM 10-U

Terminal Covers
Single pole terminal cover.
Supplied standard with Type
K2x240(IP) terminals.
Can be used for bolt-on or
cable lug connection.

+H-NZM 10-O

One piece, 3 pole terminal


cover.
Suitable for use with Type
K300 or K2x120 terminals.

+HH-NZM 10-O

+H-NZM 10-U

+HH-NZM 10-U

Type

Price

Individual
terminals supplied
separately for field
mounting
$

K2X240IP-NZM 102)

K2X240-NZM 102)

K300-NZM 10

K2x120-NZM 10

H-NZM 10

HH-NZM 10

NZM 10 Circuit Breakers and Molded Case Switches are supplied standard with bolt-on connection. For Line and Load field-wiring terminals for
cable connection, select from information specified above.
All terminals can be ordered factory installed with the device (Column 4) or separately for field installation (Column 6).
Ordering information:
Specify Type from Columns 4 or 6. Example: + K2 x 240IP-NZM 10-O

1) When ordering with the device (Column 4), the Type suffix specifies which side should be equipped with terminals:
Suffix O - Denotes a set of three terminals and covers mounted on the top.
Suffix U - Denotes a set of three terminals and covers mounted on the bottom.
Note: All Moeller Electric Molded Case Circuit Breakers, including the NZM 10, are UL listed and CSA certified for reverse
feed connection and can therefore be fed optionally from top or bottom.
2) Complete set of three (for top or bottom) Type K2x240(IP) terminals for field installation (column 6) consists of the following:
- Qty. of one K2x240IP terminal, which is supplied with one H-NZM 10 terminal cover and one insulating plate.
- Qty. of two K2x240 terminals, which are supplied each with one H-NZM 10 terminal cover.

For Immediate Delivery call KMParts.com at (866) 595-9616

8/71

Circuit Breakers
Disconnect Switches, Molded Case Switches

Amps

See Price List See Price List See Price List See Price List See Price List See List Price See Price List See Price List

Conductor
Cross-section
Range and Material

See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List

Maximum
Rated
Current

See Price List See Price List See Price List See Price List See Price List See List Price See Price List See Price List

See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List

General info

Circuit-Breakers, NZM... 4, 6, 9, 12
Tripping Characteristics
16

2h
100

25 40 63 80 100 A

Setting current
NZMH 4-...

Minutes

Tripping time

40
10
4
1
40
Seconds

Tripping characteristics
The tripping characteristics show the tripping time of the
breakers in relation to the response current.
The mean values of the tolerance bands are indicated at an
ambient temperature of 20C, starting from cold.
The tripping time of overload releases at operational temperature reduces to approximately 1/4 of that shown.

10
4
1
200

100

Milliseconds

800

320

400

1000

500

100
40
10
4
Minimum command time

1
6

10

20

40

100

200

400

1000 2000 3000

25 40

2h
100

125 200
63 100 160
A

Setting current
NZM(H) 6(B)-.../ZM 6-...
Tripping time

Minutes

10
4

4
1

160
100

260

400

300

190

600

1150

10
4

10
4
1

1900

1000
760

475

NZM(H) 9-.../ZM 9-...

1
40
Seconds

10

400

320

400

2400

260

Milliseconds

Milliseconds

40
10
4

20

40

100

200

400

200

400

t r Ein

Minutes

2000 4000

10000 20000
A rms

NZM 12-.../ZM 12 V-...


Ser.-No. 02

10
4

t r On

1
40

Seconds

10

1000

400 630 1000 1600


315 500 800 1250
A Setting current

40

10
4

Minimum command time


100

2h
100

Tripping time

Minutes

10

40

Setting current

1
40

Seconds

40

10000
A rms

NZM 12-.../ZM 12-...


Ser.-No. 02

40

Tripping time

4000

1600

100

1000 2000 4000

400 630 1000 1600


315 500 800 1250
A

2h
100

10
4
630

1
2000

400

3200

1260
1600

2500

25000
12600
16000

400

Delay
time tv
10 ms...1000 ms

20000

100

Milliseconds

Milliseconds

1000

4
Minimum command time

40
10
4

100

800
1000

2...12 x I r

15000
7560
19200
9600
12000

1250

25000

40
2...20 x I u

10
4

Minimum command time

Minimum command time

1
100

8/72

2400

1200
600

400

100

2000

800
500

1500

A Setting current

40

1
40

Seconds

Tripping time

40

160 250
63 100 200 315

2h
100
Minutes

Circuit Breakers
Disconnect Switches, Molded Case Switches

A rms

200

400

1000

2000 4000

10000 20000

500000
A rms

100

200

400

1000 2000 4000

For Immediate Delivery call KMParts.com at (866) 595-9616

10000 20000

50000
A rms

Circuit-Breakers NZMH 4, 6, 9
Let-Through Characteristics
Let-through energy I2t
2

i dt
2
[A s]

NZMH 4-...

2.
I cc

4
3

40
63/80/100 A

2
1.5

15

40 A

10 6
8
6

10
8

16/25 A

30
20

40 A

2
1.5

10 A

10

16/25 A

8
6

3
6A

2
1.5
1

63/80/100 A

4
3

6
4

fw

60

10 7
8 NZMH 4-...
6

1 st
hal

100
80

D
[kA]

a ve

Let-through current D

4
3

Ue =380/415 V
1

1.5 2

6 8 10

15 20

30 40

10 A

6A

2
1.5

60 80 100

10 4

Icc [kArms]

Ue = 380/415 V
1

1.5 2

8 10 15 20 30

40 60 80 100

i dt 10 7
2
[A s]
8
6

4
3

4
3

2
1.5

2
1.5

160 A

4
3

125 A

2
1.5

100 A

cc

Breaking Capacity

10
8
6
4
3

2
1.5

60 A

Ue = 480 V 60 Hz

60 A
40 A

10 5
8
6
4
3

2
1.5
1

Breaking Capacity

4
3

100 A

fw

10 6
8
6

8
6

hal

10

NZMH 6-.../ZM 6

irst

[kA]

ave

8 NZMH 6-.../ZM 6...


6

i 2t f

Ue = 480 V 60 Hz

1.5 2

8 10

15 20

30 40

10 4

60 80 100

1.5 2

8 10 15 20 30 40

Icc [kArms]

60 80 100
Icc [kArms]

i dt 10 8
2
[A s]
8
6

10 2
8
6

10 7
8
6

250 A

4
3

175 A
100 A

I cc

250 A
200 A
175 A
100 A

2
1.5

10 1
8
6
4
3

4
3

Ue = 480 V 60 Hz

2
1.5
1

10 6
8
6
4
3

Ue = 480 V 60 Hz

Breaking Capacity

2
1.5

ave

2
1.5

fw

2
1.5

hal

4
3

irst

4
3

NZMH 9-.../ZM 9...

i 2t f

8 NZMH 9-.../ZM 9...


6

Breaking Capacity

[kA]

2
1.5
1

Circuit Breakers
Disconnect Switches, Molded Case Switches

Icc [kArms]

2
1.5
1

1.5 2

8 10

15 20

30 40

60 80 100
Icc [kArms]

10 5
1

1.5 2

8 10 15 20 30 40

For Immediate Delivery call KMParts.com at (866) 595-9616

60 80 100
Icc [kArms]

8/73

Circuit-Breakers, NZM 7
Tripping Characteristics, Let-Through Characteristics
Tripping characteristics, System protection
63 100 160 250 A Rated uninterrupted current

Time t
Minutes

10
4

1
40

1
40

10
4

NZM 7-...

10

10
4

400

400

100

100

Milliseconds

Milliseconds

80 125 200 A Rated uninterrupted current

2h 40
100
40

NZM 7-...

Seconds

Minutes
Seconds

Time t

2h
100
40

40
10
4

40
10
4

1
40

100

200

400

1000

10000 A rms

2000 4000

40

100

200

400

1000

10000 A rms

2000 4000

i 2 dt
(A 2 s) 10 7

D
(kA) 100
NZM 7-...N

NZM 7-...N

ave

80

60

1st

hal

f-w

6
4
2 .
Icc

Circuit Breakers
Disconnect Switches, Molded Case Switches

Let-through energy I2t

Let-through current D

40

2
1.5

30

1) NZM 7-250 N
2) NZM 7-160 N

10 6

1) NZM 7-250 N
2) NZM 7-160 N

20

6
15

4
U e = 400415 V AC

10
10

15

20

30

40

60

80

100

Icc [kArms]

8/74

U e = 400 415 V AC

2 . 10 5
8

10

15

20

30

For Immediate Delivery call KMParts.com at (866) 595-9616

40

60

80

100

Icc [kArms]

Circuit-Breakers, NZM 10
Tripping Characteristics
Inverse time and Instantaneous response
125 250

Setting current

4
1
40

Minutes

Tripping time

10

10
4
2
1

400

Setting current

NZM 10-400 N , S, H/ZM-400

10
4
1
40
10
4
1

400

400

100

I rm = (2...12) x I r

Milliseconds

40
10

100

Irm = (2...12) x I r

40
10
4

1
40

100 150

300 500 1000


250

2000 4000
3000

10000 20000
A rms

40

100

200

400

1000 2000 4000

10000 20000
A rms

Circuit Breakers
Disconnect Switches, Molded Case Switches

Milliseconds

200

2h
100
40

NZM 10-....N , S, H/ZM-250

Seconds

Seconds

Tripping time
Minutes

2h
100
40

With selectivity settings


125

Setting current

Tripping time
Minutes

4
2
1
40
12
10
6
4

t r = 2...20 s

Seconds

10

200

2h
100
40

NZM 10-400N , S/ZMV-250

400

Setting current

NZM 10-400 N , S/ZMV-400

10
4
1
40
10

t r = 2...20 s

4
1

1
600
400

Milliseconds

250

400

t v = 0....
1000 ms

100
Irmv = (2...12) x I r

40
10
4

I rm = 1....6 kA

Milliseconds

Seconds

Tripping time
Minutes

2h
100
40

t v = 0...
1000 ms

100

I rmv = (2...12) x I r

40
10

I rm = 1...9 kA

4
1

1
40

100 150 300 500


250

1000 2000 4000 10000 20000


A rms
1500 3000 6000

40

100

200

400

1000 2000 4000

For Immediate Delivery call KMParts.com at (866) 595-9616

10000 20000
A rms

8/75

Circuit-Breakers, NZM 10
Tripping Characteristics
With selectivity settings

Inverse time and Instantaneous response


300

Setting current

Minutes

10
4

630

A Setting current
NZM 10-630N , S/ZMV-630

10
4

Seconds

1
40

10
4
1

10

t r = 2...20 s

4
1

400

400

100

100

Milliseconds

Milliseconds

300

2h
100
40

NZM 10-630N , S, H/ZM-630

Tripping time

Minutes

630

1
40
Seconds

Tripping time

2h
100
40

I rm = (2...12) x I r

40
10
4

t v = 0...
1000 ms
I rm = (2...12) x I r

40
10
I rmv = 1...9 kA

1
40

100

200

400

1000 2000 4000

10000 20000
A rms

40

100

200

400

1000 2000 4000

10000 20000
A rms

Circuit Breakers
Disconnect Switches, Molded Case Switches

The tripping characteristics show the tripping time of the breakers in relation to the response current.
The mean values of the tolerance bands are indicated at an ambient temperature of 20C, starting from cold.

8
Let-through energy I2t

Let-through current D

i 2 dt
[A 2 s]

NZM 10 H

alf

-cy

cle

1H
alf-c
ycle

NZM 10 H

ID(kA)

107
9
8

1H

100
90
80
70

600 V

480 V

480 V

60

240 V

600 V

50

40

30

20

15

1.5

240 V

106

10
10

15

20

30

40

50

60 80 100

150

200

10

15

20

30

40

50

60 80 100

Icc [kArms]

8/76

For Immediate Delivery call KMParts.com at (866) 595-9616

150

200
Icc [kArms]

Molded Case Circuit Breakers, Disconnect Switches


Technical Data for NZM H4, NZM(H)6(B), NZM(H)9, NZM 12
1

Molded Case Circuit Breakers

3-pole

Frame Size

NZMH 4
...-CNA

1)

80

NZM 6B...
/ZM6A...NA

NZM H6...
/ZM6A...NA

NZM 9...
/ZM9A...NA

NZMH 9...
/ZM9A...NA

NZM 12...2)
/ZM(A)...NA

125

125

250

250

1000

IEC 60 947-2 Circuit Breaker Electrical Ratings


Rated impulse withstand voltage Uimp
Rated operational voltage Ue 50/60 Hz
Rated short-circuit making capacity Icm
Short Circuit Interrupting Ratings:

V
V
kA

8000
500
220

8000
690
275

8000
690
275

8000
690
73

8000
690
220

kA
cos
kA
cos
kA
cos
kA
cos
kA
cos
kA
cos
kA
cos
kA
cos

100
0.2
75
0.2
100/65
0.2
50/33
0.25
20
0.3
10
0.5

125
0.2
95
0.2
100/90
0.2
50/45
0.25
35
0.25
18
0.3
20
0.3
5
0.7

125
0.2
95
0.2
100/90
0.2
50/45
0.25
35
0.25
18
0.3
20
0.3
5
0.7

35
0.25
18
0.3
35
0.25
18
0.3
25
0.25
13
0.3
10
0.5
10
0.5

100
0.2
75
0.2
100/90
0.2
75/68
0.2
65
0.2
33
0.25
28
0.25
14
0.3

kA
kA
kA

30
20
12

30
20
12

30
20
12

25
20
15

35
30
25

kA
kA
kA

25
25
14

100
65
25

30
25
18

200
85
42

65
65
50

Icu IEC/EN 60 947 Test cycle O-t-CO


Ics IEC/EN 60 947 Test cycle O-t-CO-t-CO
Icu
Icu
380-400/415 V 50/60 Hz

Icu
Ics

500 V 50/60 Hz

Icu
Ics

660/690 V 50/60 Hz

Icu
Ics

DC voltage T 15 ms
110 V DC
250 V DC
440 V DC

Circuit Breakers
Disconnect Switches, Molded Case Switches

220 240 V 50/60 Hz

UL 489/CSA 5 Short Circuit Interrupting Ratings


240 V 60 Hz
480 V 60 Hz
600 V 60 Hz

General technical data


Mounting position

Standards

UL 489, CSA 22.2 # 5.1


IEC/EN 60 947-2, VDE 0660

Climatic proofing

Damp heat, constant, to IEC 60 068-2-3


Damp heat, cyclic, to IEC 60 068-2-30

90
901 )

Ambient temperature, min./max. C


Open
25/+55 (Lower temperatures on request)
Enclosed
25/+40 (Lower temperatures on request)
90

Mechanical shock resistance

90

25 g (shock duration 20 ms)

1) Type NZMH 4-...-CNA Thermal-Magnetic devices (16 80 Amps) are rated as circuit breakers per IEC/EN 60 947-2 only. Consult page 8/ 5 for further info.
2) Type NZM 12-...- NA circuit breakers are UL/CSA only. Consult Moeller Electric for IEC/EN rated versions.

For Immediate Delivery call KMParts.com at (866) 595-9616

8/77

Molded Case Circuit Breakers, Disconnect Switches


Technical Data for NZM H4, NZM(H)6(B), NZM(H)9, NZM 12
1

Frame Size

Amps

NZMH4...CNA1)
80

NZM 6B...
/ZM6A...NA
125

NZM 9...
/ZM9A...NA
250

NZMH 9...
/ZM9A...NA
250

NZM 12...
/ZM(A)...NA2)
1000

Overload Trips
Bimetal Type (directly heated)
Solid State Type
Temperature compensation residual error in
the range 25/+55 C (reference 20 C)

Amps
Amps
%/K

4 80

0.3

15 125

0.7

15 125

0.7

63 250

0.3

63 250

0.3

300 1000

Undervoltage Trips
Pull-in Voltage range
Dropout voltage range
Minimum command time
Inrush Rating AC
Sealing AC
Inrush Rating DC
Sealing DC

%Us
%Us
ms
VA
VA
W
W

85 110
70 35
10 15
6.5
3.5
2.8
2.8

85 110
70 35
10 15
6.5
3.5
2.8
2.8

85 110
70 35
10 15
6.5
3.5
2.8
2.8

85 110
70 35
10 15
40
7
1.9
1.9

85 110
70 35
10 15
40
7
1.9
1.9

85 110
70 35
10 15
100
12
160
3.6

Shunt Trips
Pull-in Voltage range
Minimum command time
Inrush Rating AC
Sealing AC
Inrush Rating DC (intermittent duty operation)

% Us
ms
VA
VA
W

70 110
10 15
50

40

70 110
10 15
50

40

70 110
10 15
50

40

70 110
10 15
150
15
120

70 110
10 15
150
15
120

70 110
10 15
350
20
200

Switching times
Tripping in the event of a short-circuit
Minimum command time
Opening delay
Total opening delay

ms
ms
ms

2
0.3
5

3
0.3
6

3
0.3
6

4
6
20

4
0.3
6

6
12
25

Opening delay with:


Shunt Trips (100% of rated coil voltage)
Undervoltage Trips

ms
ms

10 20
15 20

10 20
15 20

10 20
15 20

10 20
15 20

10 20
15 20

15 25
20 25

A
A
A
A
A
A
A

6
6
4
1
0.8
0.7
0.3

6 (1)
6 (1)
4 (1)
1 (1)
0.8 (0.4)
0.7 (0.2)
0.3 (0.1)

6 (1)
6 (1)
4 (1)
1 (1)
0.8 (0.4)
0.7 (0.2)
0.3 (0.1)

6 (1)
6 (1)
4 (1)
1 (1)
0.8 (0.4)
0.7 (0.2)
0.3 (0.1)

6 (1)
6 (1)
4 (1)
1 (1)
0.8 (0.4)
0.7 (0.2)
0.3 (0.1)

6
6
4
1
0.8
0.7
0.3

Ops.
Ops.

20000
5000

20000
5000

20000
5000

20000
7500

20000
7500

10000
2500

A gL

PKZM 02.5
10

PKZM 02.5
10

PKZM 02.5
10

PKZM 02.5
10

PKZM 02.5
10

PKZM 02.5
10

A 600/P 600
C 300

A 600/P 600

A 600/P 600
C 300

A 600/P 600
C 300

A 600
A 600

Molded Case Circuit Breakers

Circuit Breakers
Disconnect Switches, Molded Case Switches

NHI, VHI, AHI, RHI auxiliary contacts 3)


IEC/EN 60 947 Ratings
Rated operational current Ie
AC-15
115 V 50 Hz
230 V 50 Hz
400 V 50 Hz
DC-13 (L/R 200 ms) 24 V DC
60 V DC
110 V DC
220 V DC
Lifespan, electrical
to AC-15
to DC-13
Short-circuit rating without welding
(contacts closed)
Fuseless
Fuses
UL/CSA Pilot Duty Ratings
Type NHI
Type VHI, AHI, RHI

Pilot Duty A 600/P 600


C 300

NZM H6...
/ZM6A...NA
125

1) Type NZMH 4-...-CNA Thermal-Magnetic devices (16 80 Amps) are rated as circuit breakers per IEC/EN 60 947-2 only. Consult page 8/5 for further info.
2) Type NZM 12-...- NA circuit breakers are UL/CSA only. Consult Moeller Electric for IEC/EN rated versions.
3) For IEC/EN 60 947 ratings, values which appear in parenthesis apply to VHI, AHI, and RHI contacts. Otherwise, values apply to all contacts.

8/78

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit Breakers, Disconnect Switches


Technical Data for NZM H4, NZM(H)6(B), NZM(H)9, NZM 12
1

UL/CSA Motor Disconnect Switches with


adjustable thermal and magnetic trips
IEC/EN Molded Case Circuit Breakers

3-pole

NZMH 4-...-CNA

NZM(H)6(B)/ZM6-..CNA NZM(H)9/ZM 9-...CNA

Frame Size

Amps

80

125

250

Page 8/77
Page 8/77, 78

Page 8/77
Page 8/77, 78

Page 8/77
Page 8/77, 78

Amps
HP

4 80
Page 8/5
Page 8/78

15 125
Page 8/14
Page 8/78

63 250
Page 8/24
Page 8/78

UL/CSA Motor Disconnect Switches without


adjustable thermal and magnetic trips
IEC/EN Switch-Disconnectors

3-pole

N 6-..CNA

N 9-...CNA

N 12-...CNA

Frame Size

Amps

150

250

1200

Page 8/77

Page 8/77

Page 8/77

8000
3
20000
60
10
5
1

8000
7
20000
60
10
5
0.5

8000
20
30000
60
10
5
0.5

Page 8/15
Page 8/78

Page 8/25
Page 8/78

Page 8/33
Page 8/78

Motor Disconnect Switches without


adjustable thermal and magnetic trips
General Technical Data
IEC/EN 60 947-3 Switch Disconnector Ratings:
Rated Impulse Withstand Voltage
Rated short-time withstand current Icw (1 s current)
Lifespan, mechanical
Maximum operating frequency
Lifespan, electrical
AC-1
AC-2, AC-3
DC-2, DC-5
UL 508/CSA 22.2 # 14 Motor Disconnect switches
HP Ratings
Auxiliary Contacts, Voltage Trips
Mounting Position

V
kA
Ops.
Ops./h
Ops. x 103
Ops. x 103
Ops. x 103

Circuit Breakers
Disconnect Switches, Molded Case Switches

Motor Disconnect Switches with


adjustable thermal and magnetic trips
General Technical Data
IEC/EN 60 947-2 Circuit Breaker Ratings
UL 508/CSA 22.2 # 14 Motor Disconnect switches
Adjustable range of thermal overload trips
HP Ratings
Auxiliary Contacts, Voltage Trips

90
901 )

90

90

For Immediate Delivery call KMParts.com at (866) 595-9616

8/79

Molded Case Circuit Breakers, Disconnect Switches


Technical Data for NZM H4, NZM(H)6(B), NZM(H)9, NZM 12
Type
Maximum continuous
current

Field Wiring Terminals


Conductor Cross-Section

NZMH 4-...-OBI-CNA

NZMH 4-...-CNA

NZM(H)6(B).../ZM 6(A)...-(C)NA
NZM(H)6(B).../ZM 6...-OBI-CNA

NZM(H)6(B)-160/ZM 6(A)-125-(C)NA
NZM(H)6(B)-160/ZM 6-125-OBI-CNA

18

80

100

125

1 Conductor:
AWG 14 3
Cu Only

1 Conductor:
AWG 14 3
Cu Only

1 Conductor:
AWG 14 1/0
Cu Only
Up to 90A, 60/75C Cable
100A, 60C Cable

1 Conductor:
AWG 4 3/0
Cu Only
125A, 60C Cable

10

15

Terminal Torque Rating Nm 4

Type

Circuit Breakers
Disconnect Switches, Molded Case Switches

Maximum continuous
current

Field Wiring Terminals


Conductor Cross-Section

Terminal Torque Rating

NZM12-..../ZM 12(V)(A)-....-NA

250

800

1 Conductor:
AWG 8 Kcmil 300
Cu only

1 Conductor:
Kcmil 250 600
2 Conductors:
AWG 3/0 Kcmil 500
3 Conductors:
Kcmil 250 400
Cu + Al

4 Conductors:
AWG 2 Kcmil 500
Cu + Al

50

50

N 9-...-CNA

N 12-...-CNA

Nm 40

Type
Maximum continuous
current

NZM(H) 9.../ZM 9(A)...-(C)NA


NZM(H) 9.../ZM 9...-OBI-CNA

N 6-...-CNA
A

1000

100

150

250

800

1000

1200

1 Conductor:
AWG 14 1/0
Cu Only
75C Cable

1 Conductor:
AWG 4 3/0
Cu Only
75C Cable

1 Conductor:
AWG 8 Kcmil 300
Cu Only

1 Conductor:
Kcmil 250 600
2 Conductors:
AWG 3/0 Kcmil 500
3 Conductors:
Kcmil 250 400
Cu + Al

4 Conductors:
AWG 2 Kcmil 500
Cu + Al

4 Conductors:
AWG 2 Kcmil 500
Cu + Al

15

40

50

50

50

Field Wiring Terminals


Conductor Cross-Section

Terminal Torque Rating Nm 10

Note:
All devices shown above except Types NZM 12-... are dual rated UL/CSA and IEC/EN.
Consult Moeller Electric for IEC/EN Conductor Cross-section information.

8/80

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit Breakers,


Technical Data for NZM 7..., NZM 10...
1

Molded Case Circuit Breakers

NZM

Frame Size

7(A)...N-NA1)

NZM 10-...N-NA

NZM 10-...S-NA

NZM 10-...H-NA

Amps

150

600

600

600

V
V

8000
690
III/3

8000
690
III/3

8000
690
III/3

8000
690
III/3

kA

94.5

143

220

440

kA
kA

45
45

65
33

100
50

200
100

Rated impulse withstand voltage Uimp


Rated operational voltage Ue 50/60 Hz
Overvoltage category/pollution degree
Short Circuit Interrupting Ratings:
Rated short-circuit making capacity Icm
Rated short-circuit breaking capacity Icn
Icu IEC/EN 60 947 Test cycle O-t-CO
Ics IEC/EN 60 947 Test cycle O-t-CO-t-CO
230 V AC
Icu
Ics
400/415 V AC

Icu
Ics

kA
kA

35
35

45
23

65
33

100
50

440 V AC

Icu
Ics

kA
kA

25
19

45
23

55
28

85
43

500 V AC

Icu
Ics

kA
kA

12
9

30
15

42
21

65
33

690 V AC

Icu
Ics

kA
kA

6
6

20
10

25
13

30
15

kA
kA
kA

65
25

65
42
35

100
65
42

200
100
50

Circuit Breakers
Disconnect Switches, Molded Case Switches

IEC 60 947-2 Circuit Breaker Electrical Ratings

UL 489/CSA 5 Short Circuit Interrupting Ratings


240 V 60 Hz
480 V 60 Hz
600 V 60 Hz

General technical data

Mounting

Standards

UL 489, CSA 22.2 # 5.1


IEC/EN 60 947-2, VDE 0660

Shock Hazard Protection

Finger-Safe, Back of Hand safe

Climatic proofing

Damp heat, constant, to IEC 60 068-2-3


Damp heat, cyclic, to IEC 60 068-2-30

Ambient temperature
Min/Max C

25/+40 (At 100% loading )

Mechanical shock resistance

20 g (shock duration 20 ms)

From a vertical position, up to 90


in any direction

90

90
90

90

1) Type NZM 7(A)-...-N-NA molded case circuit breaker UL/CSA only. Conformity with data shown per IEC/EN 60 947-2 pending. Consult Moeller Electric for IEC/EN version.

For Immediate Delivery call KMParts.com at (866) 595-9616

8/81

Molded Case Circuit Breakers


Technical Data for NZM 7..., NZM 10...
1

Molded Case Circuit Breakers

AC = 50/60 Hz

NZM 7...

NZM 10...

EK...(NHI/RHI)

VHI

NHI/RHI/VHI

A
A
A
A
A
A
A
A

6
6
4
2
6
3
1
0.5

4
4
2
1
3
1.5
0.5
0.2

6
6
3
1.5
1
0.8
0.7
0.3

Short-circuit protection: Max. Fuse, IEC Type


Max. Miniature Circuit Breaker

A
A

10
10

10
6

6
6

Terminal capacity: IEC/EN: 1 or 2 conductors, solid or stranded


UL/CSA

mm2
AWG

0.75 2.5
18 14

0.75 2.5
18 14

0.5 2.5
18 14

A 600/ P 300

C 300/ Q 300

10A @ 600 VAC


.5A @ 125 VDC
.25A @ 250 VDC1)

Auxiliary contact types


IEC/EN 60 947 Electrical Ratings
Rated operational current Ie
AC-15

DC-13

Circuit Breakers
Disconnect Switches, Molded Case Switches

115 V
230 V
400 V
500 V
24 V
60 V
110 V
220 V

UL/ CSA Electrical Ratings


Pilot Duty Ratings AC/DC
Current Ratings

Voltage Trips
Shunt Trip
Operational voltage rating Ue
Operating range (Us = Rated Control Voltage)
Rating
Pull-in
Sealing

AC/DC
AC/DC

Undervoltage Trips
Operational voltage rating Ue
Operating range:
Rating:

Dropout
Pickup
Pull-in
Sealing

AC/DC
DC/DC
AC/DC
AC/DC

Terminal capacity
IEC/EN: 1 or 2 conductors, solid or stranded
UL/CSA
Remote Control Drives
Rated Control Voltage Us

V AC
V DC
AC
DC

12 480
12 125
0.7 1.1 x Us
0.7 1.1 x Us

24 600
24 600
0.7 1.1 x Us
0.85 1.1 x Us

VA/W
VA/W

2/2

5/3
3/3

V AC
V DC
VA/W
VA/W

24 480
24 125
0.7 0.35 x Us
0.85 1.1 x Us
2/2
2/2

24 600
24 600
0.7 0.35 x Us
0.85 1.1 x Us
5/3
5/3

mm2
AWG

0.75 2.5
18 14

0.5 2.5
18 14

V AC
V DC

48 240
24 240
0.85 1.1 x Us
0.85 1.1 x Us

110 415
24 240
0.8 1.1 x Us
0.85 1.1 x Us

Operating range

AC
DC

Power Draw

110/120 V AC
220/240 V AC
380/415 V AC
24 V DC
48/60 V DC
100/130 V DC
110/120 V DC
220/240 V DC

VA
VA
VA
W
W
W
W
W

400
400
1000
350
400

400
400

240
320
440
240
240
240

240

Operations

ms
Ops.
Ops./h

100
20000
20

60/30
10000
20

mm2
AWG

0.75 2.5
18 14

0.5 2.5
18 14

Total closing/opening time


Lifespan, mechanical
Maximum operating frequency
Terminal capacity: IEC/EN: 1 or 2 conductors, solid or stranded
UL/CSA
1) Above 150 VDC, same polarity

8/82

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Switches, NZM 7... and 10...


Technical Data, Terminal Capacity
1

NZM 7-...-NA

NZM 10...N/B-NA

200

600

Refer to p. 8/45

Refer to p. 8/61

Ops.
Ops./h

8000
3.5
III/3
20000
120

8000
8
III/3
20000
60

Ops.

3000/2000

10000

UL/CSA Molded Case Switches


IEC/EN Switch-Disconnectors
A

Frame Size
General Technical Data
UL 1087/ CSA 22.2 # 5.2 Molded Case Switches
IEC/EN 60 947-3 Switch Disconnector Ratings:
Rated Impulse Withstand Voltage
Rated short-time withstand current Icw (1 s current)
Overvoltage category/pollution degree
Lifespan, mechanical
Maximum operating frequency
Lifespan, electrical
AC-1
400 V/690 V

V
kA

Type

NZM 7(A)-...N-NA
Molded Case Circuit Breaker

NZM 7-...-NA
Molded Case Switch

NZM 10...-NA
Molded Case Circuit Breakers and Switches

150

200

1 Conductor:
AWG 14...250 kcmil
Cu Only

1 Conductor:
AWG 14...250 kcmil
Cu Only

14

14

NZM 7(A)-...N-NA-M8
Molded Case Circuit Breaker

NZM 7-...-NA-M8
Molded Case Switch

M8

M8

Maximum continuous current

Field Wiring Terminals


Conductor Cross-Section

Terminal Torque Rating Nm

Bolt-on Connection size

Refer to Page 8/71

Let-Through Values for UL/CSA Fuseless Current Limiting Circuit Breakers


1

Type

NZMH 6-.../ZM 6A-...-NA

NZMH 9-.../ZM 9A-...-NA

NZM 10H-.../ZM 10(A)-...-NA

125

250

600

Maximum continuous current

Current Limiting Values @

Circuit Breakers
Disconnect Switches, Molded Case Switches

Terminal Capacity

240V

480V

600V

240V

480V

600V

240V

480V

600V

Threshold Current
RMS Sym
kA
Peak
kA
I2t x 103
A2s

7.5
9
350

7.5
10
430

7.5
10.6
468

16.25
18
1500

16.25
21
2000

16.25
23
2204

39
34
2800

39
42
5500

39
40
5500

Intermediate Current
RMS Sym
kA
Peak
kA
I2t x 103
A2s

50
22
800

42
26
1300

14
16
1000

100
36
1800

50
38
5000

30
32
5000

125
50
3500

65
52
6600

42
45
7200

High Interrupting Capacity


RMS Sym
kA
Peak
kA
I2t x 103
A2s

100
30
1000

65
35
2100

25
21
1590

200
42
3200

85
48
6000

42
39
6300

200
55
4000

100
61
8000

50
48
8000

For Immediate Delivery call KMParts.com at (866) 595-9616

8/83

Molded Case Circuit-Breakers and Disconnect Switches


Dimensions for Type NZMH 4, 6 and 9
Circuit-breakers
+A-NZMH 4
+U-NZMH 4
90
82
58

+h
58

Drilling Template

20

95

82

138
160

98

+R

98

75

75

12

16

12
12

NZMH 4-...-OBI-CNA
NZMH 4-...-CNA

30.5

4.3

30,5

16

3 M 4 50
50

+h

Type

N 6-...-CNA

NZMH 6/ZM 6(A)-(C)NA 210


NZM 6 B/ZM 6(A)-(C)NA 210

a1

133

109
109
109

180
180

125

92
112
112

95
95
95

106
126
126

7
7
7

1)

55

110

16

15

15

12

+h

Drilling Template

+A-NZM
+U-NZM

b
g
66

a1
e
h

58

10

+R

d
a

4.5

6
38

38

55

SVB
~40

70

+h
+2 M 4 45

144
32.5

N94,NZM 94

64
42

18

+h

+A-NZM
+U-NZM

11

b1
b
84
42

18
16

N 9-...-CNA
NZM 9/ZM 9(A)-...(C)NA
NZMH 9/ZM 9(A)-...(C)NA
NZMH 9/ZM 9-OBI-CNA

45

58

206

45

26

3 M5 40

X5

+R

279

279
285
322

211

206

Type
240
217
211

SVB
~40

+ MV
+h

Notes: Safety vertical clearance between upper edge of


NZM circuit-breakers and conductive materials
with a different potential:

Type
NZM 4
NZM 6
NZM 9

8/84

59

126
10

Circuit Breakers
Disconnect Switches, Molded Case Switches

N6-...-CNA
NZMH 6/ZM 6(A)-(C)NA
NZM 6B/ZM 6(A)-(C)NA
NZM(H)6B/ZM 6-OBI-CNA

4.2

4 M5 40
126

+R: When switch shaft extended to the rear: provide


20 mm diameter hole in mounting plate for switch shaft.
Front switch shaft is then omitted except for frame sizes 4
and 6.

40 mm
60 mm
100 mm

For Immediate Delivery call KMParts.com at (866) 595-9616

b1

N 9-...CNA
140
NZM 9/ZM9...-NA 140
NZMH 9/ZM9.-NA 140

Molded Case Circuit-Breakers and Disconnect Switches


Dimensions for Type NZM 12
N12...-CNA (630, 800)
NZM 12-.../ZM 12 (A)(V)-...-NA (630, 800)

N 12-1000-CNA
NZM 12-1250/ZM (V)-1000-NA

190
+h

319
197

79

59
166.2
184

118

65
65

M6
M8

60

40

60

248
296

516

537

99
65

65

12

69
118

420
320
142

32

79 79

N12...

109

112

79

276

+R

99

197

588

319
516

32
+R

537

99

12

65

69
118

420
320
142

588

94

276

25

46

40

94
a

+h
+K300

112

25

46

190
276

248

N12...

296

NZM12...

6
59

10
166.2
184

6 M6 x 20/
4 M8 x 20

Type

Terminal bolts
M16 x 50

630
1000

800

1250

NZM 12

a
b

8
8.5

10
8.5

10
8.5

ZM 12

10

10

15

Circuit Breakers
Disconnect Switches, Molded Case Switches

NZM12...

N 12-1200-CNA
+K 240AL-NZM

525

474

105

79

15

79

Notes: Safety vertical clearance between upper edge of NZM


circuit-breakers and conductive materials with a different potential:
Type
NZM 12

180 mm

For Immediate Delivery call KMParts.com at (866) 595-9616

8/85

Molded Case Circuit-Breakers and Disconnect Switches


Dimensions for Type NZMH 4, 6, 9 and 12
Standard handle

Door coupling rotary handle


b

Handle for switch shaft extended to


rear

d = 68 mm
b = min. 36 mm

For NZM 4
H 6(-NA)
55.5

35

Mounting opening as on left, but turned


clockwise through 90

104107

11
5

70

25
3644

60

52

60

33

H 6 R(-NA)

84

15

+ 1

84

11

0
15

2830.5

50

70

H4U

51

25

60
51

H6U

H 6(-NA)
55.5

40

60

38

H 6 R(-NA)
Mounting opening as on left, but turned
clockwise through 90
11

25
3644

117122
5

70

2830.5

70

11

70

84

+ 1

84

52

60

0
15

15

60
51

51
25

For NZM 9
H9U

H 9(-NA)
4.55

52
50

H 9 R(-NA)
4045
58

155163

90

90

60

67

11

4
10

60
93

25

15

60

3840

25

10
4

18

5
11

63
63

For NZM 12
H 12(-NA)

H 12 R(-NA)

60
58

5254

55.5

H 12 U

76
25

11

114

194209

114

76

60

87

19

15

5
11

+ 1

0
19

4045

0
21

16

0 +1

62

Circuit Breakers
Disconnect Switches, Molded Case Switches

For NZM 6

25
60

8/86

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit-Breakers and Disconnect Switches


Dimensions for Type NZMH 4, 6, 9 and 12
K(V), KU coupling kits

25

KV-2 NZM

a
a

Type

NZM 4
NZM 6

125
125

145185
150190

NZM 9
NZM 12

150
300

190240
240300

Circuit Breakers
Disconnect Switches, Molded Case Switches

For Immediate Delivery call KMParts.com at (866) 595-9616

8/87

Molded Case Circuit Breakers and Switches


Dimensions for Type NZM 7...
Circuit Breakers, Molded Case Switches

35

23

29.5

28

22.5

60

129.5
105

4.5

1)

NZM 7.....-NA

62

130
139
175
184

13
6

44.5

35

SW 5
105

M4 x 50

Shunt Trips, undervoltage Trips


and Early-Make auxiliary contacts
A-, U-, VHI-NZM 7

26.5

34

93.5

Circuit Breakers
Disconnect Switches, Molded Case Switches

140

20.3

18

8
Insulating frame
RT-NZM 7
Mounting opening for insulating frame

93

40
69

131.5

107
122

3.5
28
10

8/88

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit Breakers and Switches


Dimensions for Type NZM 7...
Rotary drive/rotary handle for open mounted breakers and switches
DA(OV)-NZM 7

HU-NZM 7
27

46
15

87.5

1.5

66

DA(OV)-NZM 7

45.5

,5

90

52

HU-NZM 7

32.5

140

Up to 3 padlocks
can be fitted

52.5
105

Circuit Breakers
Disconnect Switches, Molded Case Switches

d = 48 mm
b = min. 34 mm

Extension shaft
A400-NZM = mounting depth 175400 mm
A600-NZM = mounting depth 260600 mm

282 mm (A400-NZM 7)
482 mm (A600-NZM 7)

A400(600)-NZM 7

15

8
Door interlocking handle for base mounted breakers and switches
(R)H-NZM 7
HOV-NZM 7
52.5

Mounting opening for


door coupling rotary handle

14
20

48

40
[

d = 48 mm
b = min. 34 mm

64

150

90
.0

64

18

Up to 3 padlocks
can be fitted

48

25
6
62

For Immediate Delivery call KMParts.com at (866) 595-9616

8/89

Molded Case Circuit Breakers and Switches


Dimensions for Type NZM 7
Mechanical interlock
KV-2 NZM 7

54

approx. 45

125

Rotary drive

Clip plate

35

17

105

Cable lug/cable lug cover KA 250-NZM 7

M8

53

281

M8

105
140

8/90

56,5

53

Circuit Breakers
Disconnect Switches, Molded Case Switches

130
169

C-NZM 7

64,5

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit-Breakers and Switches


Dimensions for Type NZM 7...
Side wall operator
SWA-NZM 7

88

36

NZM 7-...-NA

154

134

36

Type

25
63

50270

14

Mounting bracket for side wall operator


Mounting aperture for rotary handle

MSWA-NZM7

SWA-NZM7-L

X 7

48

100

175

Circuit Breakers
Disconnect Switches, Molded Case Switches

MSWA-NZM 7

X 7

48

139.5
157

48
83

189.5

198

Remote Control Drive

R-NZM 7
Type

NZM 7(A)-...N-NA
NZM 7-...-NA

232.2

251

98

90
109

279

d
16

58

175

65

d = 48 mm
b = min. 34 mm
Up to 3 padlocks
can be fitted

R-NZM 7 (tilted)

For Immediate Delivery call KMParts.com at (866) 595-9616

8/91

Molded Case Circuit Breakers and Switches


Dimensions for Type NZM 10...
Circuit Breakers, Molded Case Switches
NZM 10-...-NA

23

105

37

fr M6 50
70

16

18.5

M12

19

153

105

35

70

75
1)
max.45

When mounting devices side by side, 15mm


clearance is required between them.

1) Safety clearance is required to conductive


materials having a different potential; does not
apply to connected stripped conductors.

286

87

254

245
250

197

46

44

70

70
28

70
210

M-NZM 10(4)

280
K2 240

K300

Rotary drive
D-NZM 10
200
105

43
30

151

34

46
48,7

56,5

30

OFF
TRIP
ON

H 10 U
D-NZM 10

27

286

13

30

7
34
NZM 10(4)-...
P 10(4)-...

150
210

Door Interlocking handle


(R)H 10-NA

158-165

19.5
9.8
4.55

8
0
R1

11

3840

15

5
11
19.7
4.7

180

0
R3

90

14

11
5

67
R

11
5

67

60

4.55

Drilling template
(R)H 10-NA

3840

Circuit Breakers
Disconnect Switches, Molded Case Switches

K2 120

64.5
2-5

8/92

For Immediate Delivery call KMParts.com at (866) 595-9616

Molded Case Circuit Breakers and Switches


Dimensions for Type NZM 10...
Pushbuttons for enclosed breakers/switches operated with a remote control drive
MD-NZM 10
MDV-NZM 10

Mounting opening for pushbuttons


22

250285

285400

22

67

34
44

66

5.5

35

10

90

25

Protective cover for door cutout


RTR-NZM 10

Mounting opening
83

90

83

X 5.5

80

200205

268

24

15

80

90

229

262.5

21

30

25

235

61.8

Ground Fault Trip Unit

130

131

M12 35

46

19

87.5

82.5

37.5

TV-NZM 10

37
70
75
70

28
105

M-NZM 10

70
210
280