TM 10 6670 277 13 and P
TM 10 6670 277 13 and P
TM 10 6670 277 13 and P
TECHNICAL MANUAL
TM 106670-277-13&P
Department of the Army forms and procedures used for equipment maintenance will be those described
by DA Pam 738750, The Army Maintenance Management System.
12.
You can help improve this manual. If you find any mistakes or if you know of a way to improve the
procedures, please let us know. Mail your letters, DA Form 2028 (Recommended Changes to
Publications and Blank Forms), or DA Form 20282 located in the back of this manual, directly to:
Commander, U.S. Army Troop Support Command, ATTN: AMSTR-MCTS, 4300 Goodfellow Blvd.,
St. Louis, MO 63120-1798. A reply will be furnished to you.
1-3.
Refer to TM 750-244-3 for instructions covering the destruction of Army Material to prevent enemy use.
1-4. Administrative Storage of Equipment.
a. Placement of equipment in administrative storage should be for short periods of time when a
shortage of maintenance effort exists. Items should be in mission readiness within 24 hours or within the
time factors as determined by the directing authority. During the storage period appropriate maintenance
records will be kept.
b. Before placing equipment in administrative storage, current preventive maintenance checks and
services should be completed. Shortcomings and deficiencies should be corrected, and all modification
work orders (MWOs) should be applied.
C.
Storage site selection. Inside storage is preferred for items selected for administrative storage. If
inside storage is not available, trucks, vans, conex containers and other containers may be used.
i/(ii Blank)
Sartorius Analytic.
A 200 S.
Electronic Analytic Balance
Installation and Operating
Instructions
sartorius
1 Pan
8 CAL button
2 Protective ring
3 Shield plate
11 Tare bar
5 Level indicator
12 Weight display
6 Leveling screw
13 Manufacturers label
7 ON/OFF button
-1-
Sortorius analytic.
A 200 S.
With this Sartonus toploader you have acquired a sophisticated, top-of-the-line electronic balance, which will help
lighten your daily workload.
Please read these installation and operating instructions carefully before operating your new toploader.
Technical data.
Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A 200 S
Weighing range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Readability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tare range (by subtraction) . . . . . . . . . . . . . . . . . . . . . .
Standard deviation . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Max. linearity deviation . . . . . . . . . . . . . . . . . . . . . . . . .
Stabilization time (typical) . . . . . . . . . . . . . . . . . . . . . . .
Display update rate . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adaption to environment
and application
requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
g
g
g
g
g
s
s
202
0.0001
202
<+ 0.0001
<+ 0.0002
3
0.1 -0.8 (selectable)
by selection of one of
four digital filter levels
Stability range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d . . . . . . . . . . . . . . . . . selectable from 0.25...64
Ambient temperature range.... . . . . . . . . . . . . . . . . . . K . . . . . . . . . . . . . . . . . 283...313
<+ 0.0001
builtin, standard
90
257
200 x 184 x 265
230 x 291 x 343
7.5
100/120V or 220/240 V,
depending on the power
supply (adapter) being used
Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VA . . . . . . . . . . . . . . . . 9
Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RS 232 C/V24-V28,
RS 423/V10; 7-bit;
party: even, mark, odd,
space; transmission
rates 150...9600 Baud
-2-
Installation
instructions.
Choose a suitable installation site largely free of
heat radiation
corrosive substances
vibrations
- drafts.
Despite unfavorable operating conditions, your MP8 balance will deliver accurate weight results. Simply adapt it to
your requirements by programming the appropriate codes via the balance operating program. For this purpose,
please refer to the final pages of the English section.
After connection to line power, allow for >30 minutes warmup.
Important!
Pull out the power supply unit (AC/LDC adapter) prior to connecting or disconnecting peripherals.
Accessories (optional)
Carrying case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . YDB01 A
Theft prevention lock . . . . . . . . . . . . . . . . . . . . . . . . . . . 6087
Data output . . . . . . . . . . . . . . . . . . . . . . . . . YDO 0 1 A
Integratable keyboard
Data Input
with F for formulation . . . . . . . . . . . . . . . . . . . . . . . . . . . YDI 0 1 A- * *F
Printer Data Print . . . . . . . . . . . . . . . . . . . . . . . . . . . . . YDP 0 1
Complete
Consignment.
Please complete the guarantee card, indicating the installation date, and return the card to your Sartonus dealer.
Complete consignment
A complete consignment consists of the illustrated components plus a dust cover.
-3-
Startup.
Install components (3 1) in the weighing chamber one at a time in the indicated sequence.
Your balance is supplied via the power supply unit. Please check if the voltage printed on this adapter is identical to
that of your local line voltage.
Make the power connection. Secure the connection with the threaded ring. Now connect the power supply unit to a
line outlet.
At the point of use, level the balance using the leveling screws (6) such that the air bubble is centered in the circle of
the level indicator (5).
-4-
Operation.
The weight display provides the following special messages for your information:
BUSY
The processor is still busy processing other information and will not accept other functions at this time.
STANDBY
The balance was switched off with the ON/OFF function and is now in the STANDBY mode.
POWER OFF
The balance was separated from line power (fresh power connection, power failure).
CAL
The calibration function has been called.
Use the ON/OFF button (7) for switching on or off. You can also switch on with the tare bar (11).
After connection to line power, only the weight display will go off whenever you switch the balance off. The electronic
circuits remain power-supplied (STANDBY). This feature provides for instant operability the moment you switch on,
without having to wait for warmup.
After power-on, there is an automatic test of all electronic functions. Successful completion of the test is signaled by
0.0000 g in the weight display.
-5-
You must zero the display prior to weighing, if you are using a container or if the weight display does not read 0.0000
g (or the equivalent with the weight unit of your choice).
Calibration.
Internal Calibration:
Clear the pan and zero the display. Once the display reads 0.0000 g, push the CAL button (8). The display now
reads C. If YOU get CE, zero the display and push the CAL button again.
After a few seconds, the display will read CC, followed by 0.0000 g. A beeper confirms successful completion of
calibration.
-6-
External calibration:
This requires an accurate calibration weight.
Clear the pan and depress the tare button for at least three seconds until the calibration weight appears in the
display.
Place the calibration weight on the pan.
Now the weight unit symbol appears and a beeper sounds to signal completion of calibration.
You can lock both the external and the internal calibration function see Balance operating program. Both
functions are active whenever the balance operating program has been unlocked with the access switch.
In addition to grams, this balance gives you a variety of other international weight unit options to work with.
Select the weight unit you need from the table in the balance operating program, and set the appropriate code as
described in section Balance operating program.
Activate the ON/OFF button while at the same time depressing the tare bar.
-7-
After completion of the automatic power-on test, the status of the balance operating program appears in the weight
display: L stands for the list mode. In this mode, you can only verify the code setting, but you cannot program new
codes. If you want to change a program code, you must first unlock the program access.
To do so, slide the unlocking switch (10) at the forward right of your balance in the arrow direction.
The display will signal C representing the change mode, and you can now proceed to make the necessary code
changes.
After the balance operating program has been called, the display will show a continuous numerical sequence from 0
to 5 representing the page selection, in addition to the status signal L or C. When your selected number for the
page appears, push the tare bar. The page code number is now fixed in the display, and the cycle for the line
starts. Again confirm your selected number with the tare bar, and your selection will be fixed. Next the word cycle
appears,
When the 0symbol apears, this marks the actual setting.
To make changes (C mode), press the tare bar when the appropriate code appears.
Brief display of BUSY and the osymbol confirms your selection, followed by return to the zero representing the
line.
To return to the weighing program:
push the tare bar each time a 0 appears in the numerical cycle (word, line, page). If you have made code changes,
your code entry is stored as soon as the display returns to the weighing mode. Lock the balance program with the
menu access switch (display L) and replace the protective cap.
-8-
Auto-zero
This balance has an automatic zero tracking function. Any change off zero <2
digits per second will be set to zero automatically.
Additional parameters for the data output format and for calculator programs are
available on request. Please refer to Accessories.
- 9 -
ADDENDUM A
This addendum to the Sartorius Publication Number WA6002 m7/86 covers the Sartorius Analytic Balance
Model A 200 S and contains the following information:
Title
Paragraph
1
Troubleshooting
3
4
-1-
1.
Preventive Maintenance Checks and Services for Sartorius Analytic Balance ( Model A 200 S).
Routine maintenance ensures troublefree operation. Checks and services listed below should be conducted daily
and prior to each use.
Check/Service
Note
2.
Troubleshooting. Troubleshooting this equipment consists of observing results of normal operations and
results of running both the external and internal calibration checks. It also includes a thorough visual inspection of
the measuring cell and all electrical connections.
a.
b.
If you find:
error message in the display
display dark or display segments missing
you are very likely dealing with an electronic error.
3.
-2-
CAUTION
Do not touch the screen with your fingers. It is coated with a protective film.
c. Unplug connection (5).
d. Remove the eight screws (6). Carefully take off display panel.
e. Replace display panel in reverse order.
e.
b. Remove three clamps (1). Remove overlay from the display panel.
c. Take off the protective cover from the new overlay with touchpad.
d. Insert tare key overlay with the three ground connections in the display panel and fix it with glue. Place the
three clamps for the contact of the ground connection tare key overlay-display panel. Check new tare key
overlay. Use perenator to seal the joint around the tare key overlay and allow for several hours drying time.
4.
Part Number
Description
Quantity
69 13019
69 A20007-4
69 A200201
69 A20023-6
6970920
69709170-0
Leveling Screw
Overlay with Switch
Front Glass Plate
Rear Glass Plate
AC/DC Adapter (115V) (US)
LC-Display (A 200 S)
1 ea
1 ea
1 ea
1 ea
1 ea
1 ea
-3-
TM 10-6670-277-13&P
APPENDIX A
REFERENCES
A1. Scope. This appendix contains all forms, pamphlets and technical manuals referenced in both
the Air mobile and Semitrailer mounted Laboratories.
A2. Forms.
Recommended Changes to Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DA Form 2028
DA Form 20282
SF 368
Quality Deficiency Report . . . . . . . . . . . . .
Equipment Inspection and Maintenance Work Sheet . . . . . . . . . . .... .. . . . . DA Form 2404
DA Form 2062
Hand Receipts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
.......
A-1
TM 10-6670-277-13&P
Precision High Temperature Bronze Block Gum Bath . . . . . . . . . . . . . . . . TM 10-6630-234-13&P
A--6.
Miscellaneous Publications.
A-2
TM 106670-27713&P
APPENDIX B
MAINTENANCE ALLOCATION CHART
Section I. INTRODUCTION
B1.
General.
a. This section provides a general explanation of all maintenance and repair functions authorized at
various maintenance categories.
b. The Maintenance Allocation Chart (MAC) in Section II designates overall authority and
responsibility for the performance of maintenance functions on the identified end item or component. The
application of the maintenance functions to the end item or component will be consistent with the
capacities and capabilities of the designated maintenance categories.
c. Section Ill lists the tools and test equipment (both special tools and common tool sets) required for
each maintenance function as referenced from Section Il.
d. Section IV contains supplemental instructions and explanatory notes for a particular maintenance
function.
B2. Maintenance Functions. Maintenance functions will be limited to and defined as follows:
a. Inspect. To determine the serviceability of an item by comparing its physical, mechanical, and/or
electrical characteristics with established standards through examination (e.g., by sight, sound, or feel).
b. Test. To verify serviceability by measuring the mechanical, pneumatic, hydraulic, or electrical
characteristics of an item and comparing those characteristics with prescribed standards.
C. Service. Operations required periodically to keep an item in proper operating Condition i.e., to
clean (includes decontaminate, when required), to preserve, to drain, to paint, or to replenish fuel,
lubricants, chemical fluids, or gases.
d. Adjust. To maintain or regulate, within prescribed limits, by bringing into proper or exact position,
or by setting the operating characteristics to specified parameters.
e. Align. To adjust specified variable elements of an item to bring about optimum or desired
performance.
f. Galibrate. TO determine and cause corrections to be made or tO be adjusted on instruments Or
test, measuring, and diagnostic equipments used in precision measurement. Consists of comparisons of
two instruments, one of which is a certified standard of knob accuracy, to detect and adjust any
discrepancy in the accuracy of the instrument being compared.
g. Remove/Install To remove and install the same item when required to perform service or other
maintenance functions. Install maybe the act of emplacing, seating, or fixing into position a spare, repair
part, or module (component or assembly) in a manner to allow the proper functioning of an equipment or
system.
h. Replace. To remove an unserviceable item and install a serviceable counterpart in its place.
Replace is authorized by the MAC and is shown as the third position code of the SMR code.
B1
TM 10-6670-277-13&P
B3.
a. Column 1. Group Number. Column 1 lists functional group code numbers, the purpose of which is
to identify maintenance significant components, assemblies, subassemblies, and modules with the next
higher assembly. End item group number shall be 00.
b. Column 2. Component/Asse mbly. Column 2 contains the names of components, assemblies,
subassemblies, and modules for which maintenance is authorized.
c. Co/umn 3. Maintenance Function. Column 3 lists the functions to be performed on the item listed
in column 2. (For a detailed explanation of these functions, see paragraph B2.)
d. Column 4. Maintenance Cateaory. Column 4 specifies, by the listing of a work time figure in the
appropriate subcolumn(s), the category of maintenance authorized to perform the function listed in
column 3. This figure represents the active time required to perform that maintenance function at the
indicated category of maintenance. If the number or complexity of the tasks within the listed maintenance
function vary at different maintenance categories, appropriate work time figures will be shown for each
category. The work time figure represents the average time required to restore an item (assembly,
subassembly, component, module, end item, or system) to a serviceable condition under typical field
operating conditions. This time includes preparation time (including any necessary disassembly/
assembly time), troubleshooting/fault location time, and quality assurance/quality control time in addition
to the time required to perform the specific tasks identified for the maintenance functions authorized in the
maintenance allocation chart. The symbol designations for the various maintenance categories are as
follows:
1
Fault Iocate/troubleshoot the process of investigating and detecting the cause of equipment malfunctioning; the act
of isolating a fault within a system or unit under test (UUT).
Disassemble/assemble encompasses the step-by-step taking apart (or breakdown) of a spare/functional group
coded item to the/eve/of its/east componency identified as maintenance significant (i. e., assigned an SMR code) for
the category of maintenance under consideration.
B-2
TM 106670-27713&P
C . . . . . . . . . . . . . . . . . . . . . Operator/Crew
O
. . . . . . . . . . . . . . . . . . . . Unit Maintenance
B-4. Explanation Of Columns In Tool And Test Equipment Requirements, Section Ill.
a. Column 1. Reference Code. The tool and test equipment reference code correlates with a code
used in the MAC, section II, column 5.
b. Column 2. Maintenance Category. The lowest category of maintenance authorized to use the tool
or test equipment.
c.
d.
Column 4 . National Stock Number. The National stock number of the tool or test equipment.
e.
B5.
a.
b. Column 2. Remarks. This column lists information pertinent to the maintenance function being
performed as indicated in the MAC, section Il.
(2)
COMPONENT/
ASSEMBLY
ANALYTIC BALANCE
(3)
MAINTENANCE
FUNCTION
(5)
(4)
TOOLS AND
MAINlTENAN CE LEVEL
DS GS DEPOT EQUIPMENT
UN IT
D
C
O F
H
INSPECT
REPLACE
REPAIR
0.2
(6)
REMARKS
0.5
1.0
1,2
B-3
TM10-6670-277-13&P
SECTION III. TOOL AND TEST EQUIPMENT REQUIREMENTS
MAINTENANCE ALLOCATION CHART
(1)
TOOL/TEST
EQUIP.
REF CODE
(2)
(3)
(4)
(5)
MAINTENANCE
CATEGORY
NOMENCLATURE
NSN
TOOL
NUMBER
5180-00-177-7033
(50980)
SC5180-90CL-N26
MULTIMETER, 0-500V
6625-00-691-2453
B-4
TM 10-6670-277-13&P
APPENDIX C
COMPONENTS OF END ITEM AND BASIC ISSUE ITEMS LISTS
Section I. INTRODUCTION
C1. Scope.
This appendix lists components of end item and basic issue items for the Analytic Balance to help you
inventory items required for safe and efficient operation.
C2. General.
The Components of End Item and Basic Issue Items Lists are divided into the following sections:
a. Section Il. Components of End Item. This listing is for informational purposes only, and is not
authority to requisition replacements. These items are part of the end item, but are removed and
separately packaged for transportation or shipment. As part of the end item, these items must be with the
end item whenever it is issued or transferred between property accounts. Illustrations are furnished to
assist you in identifying the items.
b. Section Ill. Basic Issue Items. These are the minimum essential items required to place the
Analytic Balance in operation, to operate it, and to perform emergency repairs. Although shipped
separately packaged, BII must be with the shelter during operation and whenever it is transferred
between property accounts. The illustrations will assist you with hardtoidentify items. This manual is
your authority to request/requisition replacement BIl, based on TOE/MTOE authorization of the end item.
C3. Explanation of Columns.
The following provides an explanation of columns found in the tabular listings:
a. Column (1 ) Illustration Number (Illus Number). This column indicates the number of the
illustration in which the item is shown.
b. Column (2) National Stock Number. Indicates the National stock number assigned to the item
and will be used for requisitioning purposes.
c. Column (3) Description. Indicates the Federal item name and, if required, a minimum
description to identify and locate the item. The last line for each item indicates the CAGEC (in
parentheses) followed by the part number.
d. Column (4) Unit of Measure (U/M). Indicates the measure used in performing the actual
operational/maintenance function.
abbreviation (e.g., ea, in, pr).
e. Column (5) Quantity required (Q TY RQR). Indicates the quantity of the item authorized to be
used with/on the equipment.
C-1
TM10-6670-277-13&P
SECTION II. COMPONENTS OF END ITEM
(1)
ILLUS
(2)
NATIONAL STOCK
NUMBER
(3)
DESCRIPTION
CAGEC AND PART NUMBER
(4)
(5)
U/M
QTY
7920-00-205-0565
EA
6670-00-803-9680
SE
C-2
USABLE
ON CODE
TM 106670-277-13&P
APPENDIX D
ADDITIONAL AUTHORIZATION LIST
NOT APPLICABLE
D-1/(D-2 Blank)
TM 10-6670-277-13&P
APPENDIX E
EXPENDABLE/DURABLE SUPPLIES AND MATERIALS LIST
Section I. INTRODUCTION
E1. Scope. This listing is for informational purposes only and is not authority to requisition the listed
items. These items are authorized to you by CTA 50-970, Expendable/Durable Items (except medical,
class V, repair parts, and heraldic items).
- Operator/Crew
- Unit Maintenance
Direct Support Maintenance
General Support Maintenance
c. Column (3) - National Stock Number. This is the National stock number assigned to the item; use
it to request or requisition the item.
cf. Column (4) Description. Indicates the Federal item name, and, if required, a description to
identify the item. The last line for each item indicates the Commercial and Government Entity Code
(CAGEC) in parentheses followed by the part number.
e. Column (5) Unit of Measure (W/M). Indicates the measure used in performing the actual
maintenance function. This measure is expressed by a two-character alphabetical abbreviation (e.g.,
EA, IN, PR). If the unit of measure differs from the unit of issue, requisition the lowest unit of issue that will
satisfy your requirements.
Section II. EXPENDABLE/DURABLE SUPPLIES AND MATERIALS LIST
(1)
(2)
Level
(3)
National Stock
Number
6145-00-299-5186
Item
Number
(5)
U/M
(4)
Description
WIRE, ELECTRICAL: COPPER ; SOFT
MATERIAL; SOLID CONDUCTOR; RED;
No. 16 AWG; UNCOATED; 875.20 OHMS
PER MILE - I LB.; 20C; QQ-W-343, TYPES
LB
E-1/(E-2 Blank)
TM 10-6670-277-13&P
Temperature (Exact)
PIN:046568-000
Sincerely
Igor Chudov
http://igor.chudov.com/
Chicago Machinery Movers