Hitec Diesel Rotary Uninterruptible Power Supply UPS

Download as pdf or txt
Download as pdf or txt
You are on page 1of 22

Diesel UPS/CPS systems

Continuous power

Uninterruptible, continuous
and conditioned power supply
for mission critical applications

Power to rely on

People to rely on

Introduction
Power quality and reliability for mission critical
infrastructures are an ongoing challenge in
todays new economy. Complex systems and
processes need continuous and clean power to
maximize uptime and profitability. Uninterruptible
power is a variable in our new economy that some
have taken for granted. However, the reality of
continuous and clean power is significantly
different from that perception.

and even endanger lives. Sudden interruptions of


power can lead to serious consequences and often
irreparable damage. Consider losing data on a
banks computer, scrapping a batch of wafers in a
semiconductor plant, dropping a phone network
system for a metropolitan area: these are all
examples of power interruptions that are
unacceptable.
For critical applications, a continuous power supply
is a necessity. This is the world of Hitec Power
Protection. Our challenge is to provide customers
with a solution for their power quality problems
before any losses occur.

Power provided by the utilities can be poor and


unreliable. This is clearly demonstrated by the
numerous power outages every year that can
damage sensitive equipment, cause financial loss

As a global supplier of uninterruptible power


supply (UPS) systems, Hitec Power Protection has
become an industry leader in providing power
quality solutions to mission critical infrastructures
and processes. Our commitment to excellence has
created an unmatched reputation and allows
companies to partner with us more easily for their
long term and ongoing power solutions.

160
140

U T I L I TY FA I L U R E S / Y E A R

120
100
80
60
40

From data centers to semiconductor fabrication,


from telecommunication sites to processing plants,
Hitec Power Protection ensures that these types of
processes and infrastructures maintain their power
reliability from the shortest interruption to even the
longest power outages.

20

0m

10

- 10

0m

100

- 50

500

ms

-1

1-

3s

3-

20

0s

>2

Over 280 utility failures occur each year in every industrial country

Hitec Power Protection:


Security that goes without saying!

Power to rely on

People to rely on

The first, the best

History

For 50 years, Hitec Power Protection has been a


market leader in providing durable and reliable
UPS/CPS systems. In 1956, we first used the
combination compound generator and reactor
(choke) as our rotating filter concept, which is at the
heart of every Hitec UPS/CPS. Today we
manufacture single module systems rated up to
3,000 kVA, which can be configured to a variety of
UPS/CPS systems.

1956
First battery rotating UPS/CPS system

1963
Merger of major dutch electrical
companies to form Holec

1000

INSTALLED BASE (MVA)

800

1969

600

First diesel UPS/CPS system (300kVA)


400

200

1995

1996

1997

1998

1999

2000

2001

2002

2003

2004

2005

2006

1974
500 kVA diesel UPS/CPS system

In the meantime we have installed over 1,100,000 kVA


of UPS/CPS systems. Our quality standards and
workmanship attest to our years of experience.
This experience has also led Hitec Power
Protection to be the market leader in providing
reliable power quality solutions.

1991
First induction coupling with
free rotating inner rotor

Assured quality
Our complete business process, from engineering
and manufacturing to commissioning and customer
support, follows strict quality requirements and is
ISO 9001 certified. Our UPS/CPS systems comply
with guidelines as set forth in IEC (BS, VDE, EN,
etc.), ANSI, UL or equivalent. Additionally, we test
each UPS/CPS system prior to shipping.
We possess the largest test facilities for UPS/CPS
systems in the world, with a total capacity of 20
MVA (50 & 60Hz)!

1998
Company name changed to
Hitec Power Protection

2006
50 years dedication to customers
around the world

System description
A UPS/CPS from Hitec Power Protection is
synonymous with reliability. It filters the utility
power continuously and protects against power
interruptions in a simple and effective manner.
The unique concept and design of Hitec Power
Protection UPS/CPS maximizes its reliability and
provides the customer with the highest available
uptime. Depending upon the size of its available
fuel resource the UPS/CPS can provide power for
an indefinite time period.

The UPS/CPS
supplied with
SWITCHGEAR.
switchgear from
of your choice.

The FREE-WHEEL CLUTCH is the mechanical


interface between the induction coupling/generator
and the diesel engine. The clutch allows the shaft of
the induction coupling to rotate, while the diesel
engine is at standstill.
When the diesel engine starts and the speed of
the diesel engine reaches the speed of the
induction coupling/generator, the clutch engages
automatically and the diesel engine starts to drive
the induction coupling/generator. As a result, the
diesel engine starts and ramps up completely
without load. This ensures a fast and reliable start.

system can be
the associated
Hitec can offer
the manufacturer

The INDUCTION COUPLING is Hitec Power


Protections distinctive concept and is the heart of
the UPS/CPS. The outer rotor (red) contains a
two-pole three-phase winding that accelerates the
free-spinning inner rotor (yellow) during utility
mode. When utility fails, the UPS/CPS retrieves
power from the kinetic energy of the inner rotor by
energizing the DC winding of the outer rotor. The
amount of energy available from the inner rotor is
more than adequate to bridge the time required for
the diesel engine to start and ramp up to full speed
and power.

In utility mode, the GENERATOR acts as a


synchronous condenser (no-load over-excited AC
motor) that maintains the speed of the outer rotor
(red) of the induction coupling. It supplies reactive
power to the load and works together with the
reactor as an active filter. In the event of a utility
power failure, the generator, first driven by the
induction coupling, then by the diesel engine,
supplies power to the critical load.

Power to rely on

People to rely on

The DIESEL ENGINE sits idle in utility mode. The


engine is pre-heated and pre-lubricated to assure a
fast and reliable start. Once utility power fails or
falls outside of its tolerance, the diesel is issued a
start command and ramps up to full speed and
power.
In the meantime the induction coupling supplies the
needed power to the critical load. Total transfer
time is approximately 5...10 seconds.

The UPS/CPS is simple to operate by the digital or


analog Human Machine Interface (HMI). A complete
overview of the condition of the UPS/CPS is
provided. Remote access can be established either
through hard wiring, serial links or via Internet.

The microprocessor-based controller DiCon


performs the CONTROL of the UPS/CPS. The
DiCon is a universal controller for generator
voltage, active and reactive power, diesel speed
and induction coupling control. Its universal design
is configured by software to match all possible
systems and configurations.

The REACTOR (CHOKE) uncouples the utility


power from the load. The reactor, in conjunction
with the generator, acts as a continuous filter that
allows the UPS/CPS to maintain the output voltage
within the strictest tolerances.

Four basic principles


Hitec UPS/CPS:
Simple, sure and reliable

Hitec Power Protections unique concept for


assuring uninterruptible, continuous and clean
power rests on four basic principles. Each of them
contributes to the unprecedented advantages of
our UPS/CPS system over traditional static UPS
systems with batteries.

1. UPS/CPS = static UPS + standby generator


A traditional battery UPS system is composed of a
rectifier, batteries and inverter. The UPS provides
temporary power via its batteries and then transfers
the critical load to a standby generator that
supplements power for longer outages.
This type of system requires large areas of interior
space that are very costly. Additionally, the energy
losses generated in the battery UPS need
extensive room ventilation and the batteries
require location in a conditioned room at constant
temperature. These dedicated cooling systems
contribute heavily to the life cycle costs.

Supply side

Hitec CPS system

Our UPS/CPS system integrates this traditional


system into one. The advantages are clear. Fewer
components mean lower installation costs and
inherently higher reliability. A Hitec UPS/CPS has a
considerably smaller footprint than a battery UPS
system with standby generator. This offers
tremendous space and weight savings.

When utility power is lost, the UPS/CPS retrieves


stored kinetic energy from its induction coupling to
support the critical load until the diesel
engine takes over. This principle eliminates
environmentally unfriendly and unreliable battery
systems.

1
2

Supply side

Battery UPS + standby generator

The simplicity of our UPS/CPS vs. a battery UPS configuration


1 Double conversion power converter (static UPS)
2 Batteries (VRLA)
3 Standby generator
4 Harmonic filter

Power to rely on

People to rely on

2. Line-interactive system
Hitec Power Protection UPS/CPS systems are
line-interactive and run in parallel with the utility
power, a logical choice since, paradoxically, for the
majority of time the utility supply is of a high
quality and reliability. A line-interactive system
takes advantage of these qualities by connecting
the UPS/CPS in parallel, as opposed to series, with
the utility supply.

A traditional battery UPS continuously converts


electrical energy through rectifiers and inverters
that provide a common point of failure and reduce
its efficiency. When factoring in the energy
needed to operate a battery UPS airconditioning
requirement, a true realization of energy savings
associated with the UPS/CPS system can be
derived and realized throughout the life of your
project.

The highly efficient line-interactive system...

...compared to the traditional double conversion concept

The UPS/CPS is like a lifeguard that is always alert


and ready to jump in if necessary when utility power
fails or falls outside specified tolerances. There is
no conversion of electrical energy flowing from
utility to the critical load, making our UPS/CPS the
most efficient and reliable system available.

Line-interactive: Life guarding


your mission critical applications

3. Active filter
Outstanding qualities of the active filter:
Compensation of utility voltage deviations
Filtering of utility borne harmonic voltages
Filtering of load borne harmonic currents
No UPS/CPS borne harmonic currents / voltages
Input power factor close to unity (>0.98)

The combination of the reactor (choke) and


synchronous generator acts as a filter to clean the
incoming utility supply. This is achieved by setting
the position of the tapping so that the equivalent
circuit impedances of the generator and the reactor
give a zero impedance path (Xd + Xc = 0).
Hitecs UPS/CPS system does not utilize any
power electronics to generate, condition or convert
the output voltage, so it does not produce any
harmonics itself, unlike conventional UPSs. Instead
it acts as a harmonic filter to both supply and load
borne harmonics. Additionally, the generator
supplies the reactive power drawn by the load. The
result is that the utility power factor is always close
to unity.

Rotating filter: No load - utility


interdependencies

Reactor
(Choke)
Xb

Xa
Xc
Utility

Load

X"d

Electrical equivalent diagram of the active filter

A Hitec UPS/CPS acts as a filter for all sorts of utility disturbances

Q3
1

Q1

Q2

4
2

1 Voltage peaks

5 Radio frequency interferences

2 Frequency variations

6 Harmonic distortions

3 Brown-outs / voltage drops

7 Continuous quality power

4 Black-outs / outages

4. Battery-free solution
The UPS/CPS system from Hitec Power Protection
uses stored kinetic energy to bridge the diesel start
time upon a utility power failure. It is a battery-free
concept, which was invented and patented by
Hitec Power Protection in 1969 and continues to be
in successful commercial operation throughout the
world.

The heart of a battery UPS is also its weak link. The


huge batteries required constitute a sizeable
problem that, to the users frustration, only
becomes apparent after several years of operation.

Some typical battery associated


weaknesses illustrated

Battery-free: Problem-free

110
100
90

9
ACTUAL LIFETIME (YEARS)

80

LIFETIME EXPECTANCY (%)

70
60
50
40
30
20
10

5
25/77

30/86
35/95
Temperature (oC/oF)

40/104

45/113

50/122

55/131

A batterys lifetime expectancy drops fast at higher ambient

10
15
Theoretical Lifetime
Expectancy (Years)

The difference between theoretical and actual battery lifetime!

temperatures

Battery related issues you wont face with a Hitec UPS/CPS:


Lifetime expectancy
Battery lifetime theoretically is 5 to 15 years;
practically they last for 3 to 5 years. Economic
lifetime of a battery UPS is 10-15 years; a Hitec
UPS/CPS last for 25 years!

Environmental effects
Batteries contain environmentally harmful
materials; used batteries are chemical waste.
Disposal costs are high!

Temperature sensitivity
Battery capacity decreases significantly at low
temperatures, while lifetime halves every 10C
(18F) above 20C (68F). Installation in
conditioned rooms is a must!

Maintenance
The only sound method to monitor battery
capacity is discharge testing, which is time
consuming (battery must be disconnected from
the UPS)!

System operation

Dependent system load


Speed (rpm)

3n

1
Time

Utility mode
Q3

In utility mode, the reactor and the generator


function as an active filter that prevents any
disturbance from the utility reaching the critical
load. The generator runs as a motor and drives the
outer rotor of the induction coupling at a speed of
1500/1800 rpm. Through excitation of the two pole
three-phase winding in the outer rotor, the inner
rotor reaches a speed of 3000/3600 rpm relative to
the outer rotor. As a result, kinetic energy is stored
in the inner rotor. The outer rotor of the induction
coupling is isolated from the standby diesel engine
by the free-wheel clutch.

Q1

Change-over to diesel mode


In case of a power interruption or an unacceptable
deviation in the supply of utility power, the circuit
breaker Q1 opens. The induction couplings
DC windings are then excited, thus allowing a
transfer of stored kinetic energy from the inner rotor
to the outer rotor. The speed of the generator
remains constant at 1500/1800 rpm.

Q3
Q1

People to rely on

Q2

Simultaneously, the diesel engine starts and ramps


up to 1500/1800 rpm in less than 2 seconds, after
which the free-wheel clutch engages automatically.
For the next few seconds the diesel engine
together with the induction coupling drive the
generator to ensure a proper supply of power to the
critical load. Within 5..10 seconds the diesel engine
is the sole provider of power to the load.

Power to rely on

Q2

Diesel mode
When in diesel mode, the three-phase winding of
the outer rotor is re-energized causing the inner
rotor to ramp up to 3000/3600 rpm again. The
speed of the diesel engine is monitored and
digitally controlled to ensure a constant output
frequency. While in diesel mode, the output
frequency remains within narrow tolerances, even if
the system encounters high load steps, since the
induction coupling will be utilized to support the
diesel engine.

Q3
Q1

Q2

Back to utility mode


After utility power has stabilized, the UPS/CPS
synchronizes with utility power and closes Q1. The
diesel engine then ramps down to 1450/1750 rpm,
and as a result the free-wheel clutch disengages.
Simultaneously, the generator returns to its motor
operation and maintains the speed of the outer
rotor of the induction coupling at 1500/1800 rpm.
The diesel engine will continue to run for a short
time in a no-load condition to cool down. After the
diesel has completed its cool-down run it will shut
down and return to standby mode.

Q3
Q1

Q2

Critical and non-critical load


Once the diesel engine has reached normal
operating conditions, the non-critical load will be
switched to the output of the UPS/CPS system by
closing Q6 (Q5 has opened in the meantime).
Within approximately 10 seconds the non-critical
load will be energized again.

A single brief utility power failure can have


disastrous consequences for many mission critical
applications, i.e. data center computers, Internet
servers, etc. Other components that make up these
critical environments can be without power for
several seconds, i.e., airconditioning, lighting, etc.
One single UPS/CPS system can provide power to
both types of loads in our dual output
configuration.

Q3
Q1
Q2

Critical load

The generator of a Hitec UPS/CPS system is


always sufficiently overrated to ensure adequate
short circuit capacity to clear any downstream
faults quickly, while also being able to regulate the
output voltage closely during a utility brown-out.
When in diesel mode this excess power can be
utilized to supply non-critical loads. To enable this
option, the diesel engine rating is increased to
supply both the critical and non-critical loads. This
configuration is known as dual output.
The non-critical load is not typically connected to
the UPS/CPS output. When utility fails, the
UPS/CPS supplies uninterrupted clean power to
the critical load while the diesel engine ramps up.

Q6

Non-critical load

Q5
A dual output system optimally capitalizes UPS/CPS capacity
1 Total power rating 2 Critical load rating 3 Total power rating

With the dual output configuration you can


optimize your reliability, design and achieve a
reduced footprint. Our dual output configuration is
the most common design manufactured for our
UPS/CPS systems.

Dual output:
Optimal use of resources!

10

The unprecedented advantages of UPS/CPS


3. Line-interactive without power electronics

The simplicity of the UPS/CPS design offers


unique
characteristics
and
numerous
advantages. As the exclusive worldwide supplier,
Hitec Power Protection is able to bundle several
critical aspects together into one reliable system
that distinguishes itself from the traditional
battery UPS / standby generator combination.
Therefore, a UPS/CPS system from Hitec Power
Protection is the first and only choice!

The unique line-interactive concept of a Hitec


Power Protection UPS/CPS leads to significant
benefits. The CPS does not perform a double
energy conversion that battery UPS must execute
even when reliable utility power is available. No
power electronics are utilized; instead Hitec
incorporates a synchronous generator to supply
the load.

1. Battery-free solution!
1.0

No batteries are used in a Hitec UPS/CPS system;


instead kinetic energy is used to bridge diesel start
time. The system is not sensitive to the variety of
problems associated with the use of batteries.

Hitec Power Protections UPS/CPS concept is


simple and efficient when compared to the battery
UPS + standby generator concept: harmonic
filters, rectifiers, battery banks, inverters, static
switches, standby generator, etc ... The Hitec
Power Protection UPS/CPS integrates all these
functions into one system.

Leading

Diesel mode
(utility out of tolerance)

2. UPS/CPS = static UPS + standby generator

Power factor

Diesel mode
(utility out of tolerance)

0.98

Lagging

Utility voltage
90 %

100 %

110 %

Power factor is always close to unity (>0.98)

Features & benefits

Power to rely on

Battery-free solution

Line-interactive without power electronics

No re-investments every 3-5 years for new


batteries
No need for a dedicated climate controlled
battery room
Reduced floor space requirements
No battery disposal costs every 3-5 years
(chemical waste!)
No need for costly spill containment systems

No double energy conversion; higher efficiency


No power conversion; higher MTBF and
availability figures
No generation of harmonic currents / voltages
Long technical lifetime compared to systems
with power electronics
(25 compared to 15 years)

UPS/CPS = Static UPS + standby generator

Reactor + generator = active filter

Fewer components thus inherently more


reliable design
Higher MTBF and availability figures
Lower installation and commissioning costs
Smaller overall dimensions and floor space
requirements
Only 1 output ACB required at your supply
switchboard
Simplicity; easier to operate and maintain

High short circuit output capacity. The system


does not need to go to by-pass (use the utility)
to clear an output fault
Reactive output power supplied by generator
(pf > 0.98)
Dips and spikes on the utility voltage are blocked
Compensation of prolonged deviations of the
utility voltage
Filtering of utility borne harmonic voltages
Filtering of load side borne harmonic currents

People to rely on

11

4. Reactor + generator = active filter


The magnetically coupled tapped reactor (choke)
and generator act as an active filter, efficiently
cleaning the utility voltage from all disturbances
before reaching the load.
Additionally, our generator is able to provide a high
short circuit current of up to 14x its nominal output
current. This is another key advantage over
traditional based systems. If a short circuit occurs
downstream from the UPS/CPS, the UPS/CPS will
100

clear the fault while remaining in utility mode.


Traditional battery UPS systems are forced to
transfer to bypass and hope the utility clears the
fault. If utility power is not available during this
event, the load will be unprotected and susceptible
to a load loss. The fact that a Hitec UPS/CPS does
not transfer to bypass in this situation should not be
underestimated.

Conclusion

1100

Hitec Power Protections UPS/CPS has various


advantages over traditional UPS systems. These
advantages include reduced footprint, lower
installation costs, annual utility savings, elimination
of climate control systems, elimination of
environmentally unfriendly batteries, reduced
structural weight on your building, elimination of
compatibility problems with standby generators,
higher reliability and elimination of large
capital expenditures associated with battery
replacements.

Battery UPS
+ Standby Generator
80

880

60

660

800

1000

1200

1600

400

FLOOR SPACE (FT )

20

Hitec CPS System

FLOOR SPACE (M )

40

440

220

1800

Output Rating (kVA)

Floor space requirement of a Hitec UPS/CPS


versus a battery UPS

Lowest life cycle cost - guaranteed!


Higher output, smaller footprint, no battery
replacements, less structural weight, higher
efficiency and elimination of airconditioning
requirements result in the Hitec UPS/CPS lower
life cycle cost.
Price estimation model
Hitec Power Protection has developed a model to
estimate the life cycle cost for both a Hitec
UPS/CPS system as well as for a battery UPS +
standby generator. The model not only considers
the initial investment, but also re-investments and
yearly operating costs. We would be more than
pleased to show you the difference!

Financial lease:
Hitec Power Protection can offer you a tailored
financial lease option. For a fixed amount per year,
we can install a Hitec UPS/CPS system at your
facility. Leave the responsibility of maintenance and
service to us. They can all be included in the lease
contract!

Various lease options


To substantiate our statement of lowest life cycle
cost even further, we can offer you a variety of lease
options.
Operational lease:
Electrical energy ensured by Hitec Power
Protection up to the highest reliability at a fixed
price. We supply, install, and maintain the
UPS/CPS system. You pay us per month and leave
your worries to us!

With the variety of options to obtain a Hitec Power


Protection UPS/CPS, coupled with lower life cycle
costs, it is easier than ever to address your power
protection needs at the highest possible return on
your investment!

12

Unit configuration features


UPS/CPS systems can be delivered in a variety of
configurations. Each configuration can be tailored
to your specific needs; from a single module
UPS/CPS to a distributed redundant dual output
configuration.

Single Systems

Low voltage (LV)


UPS/CPS units:

Simplest means of providing


complete conditioning and
protection to all critical
loads.

Medium voltage
(MV) UPS/CPS
units:

Simple means of providing


complete conditioning and
protection to large loads
where LV solutions are not
ideal.

Dual output
UPS/CPS units
(LV and MV):

Removes the need for


separate gensets for
non-critical loads.

Single Output UPS/CPS System

Q3
Utility

Q2

Q1

Critical load

In a single output configuration all components


(generator, induction coupling, diesel engine and
reactor) are rated to provide continuous and clean
power to the critical load.

Medium Voltage System


For higher power ratings, medium voltage (MV)
systems can be offered. Hitec Power Protection
offers two types of medium voltage configurations.
The first option incorporates a low voltage power
module with an additional step up transformer; the
other incorporates a MV power module. Circuit
breakers and the reactor will always be configured
at the medium voltage level.

Dual Output UPS/CPS System


To ensure sufficient short circuit capacity and
guaranteeing narrow voltage tolerances, the
UPS/CPS generator is overrated. This excess
power can be used to supply non-critical loads.
The diesel engines rating must then be increased
to supply both the critical and non-critical loads.
This configuration is known as the dual output
system. When the utility fails, the UPS/CPS will
protect the critical load. As soon as the diesel
engine has started and has stabilized the critical
load, the UPS/CPS then assumes the non-critical
load by closing Q6. Virtually no additional cost or
space is required.

Single output, dual output and MV systems are


available in a variety of configurations.

Q3
Q2

Q1

Q3
Critical load

Q1

Q2

Critical load

Q6

Non-critical load

MV

Utility
Utility

LV
Q6

Non-critical load

Q5

Q5

CPS

Power to rely on

People to rely on

Dual output

13

Parallel / Parallel Redundant


Configurations

Master-Slave Configuration

Parallel Configuration
For load requirements over our largest single
module unit (3,000 kVA) parallel configurations can
be designed for increased output. Paralleling units
is also considered when redundancy is required.
The most common redundant configuration is N + 1.

An alternative configuration for two parallel units is


the master-slave configuration. This option is more
appropriate if two groups of critical outputs are
separated without a common point of coupling. The
control system maintains synchronization between
both units ensuring that the tying breaker (Q13)
can be closed at any time due to failure or
maintenance. No common point of failure is
present.

When two units are required to supply the critical


load, another unit will be installed to provide back
up should a unit fail. The total number of units,
which can be installed in parallel, is limited by the
total output current/short circuit current. Currents
over 6,000 A are not practical, i.e. total output
power is limited to approx. 4,000/5,000 kVA at
380/480 V.

A-system
Q1

Q3
Q2

Critical load

Q6

Non-critical load

Q5
Utility

B-system
Q1

Q13
Q3
Q2

Critical load

Q6

Non-critical load

Q5

Q3
1Q1

1Q2

2Q1

2Q2

3Q1

3Q2

Master-slave configuration

Q4

Critical load

Q6

Non-critical load

Utility

Q5

Parallel configuration

CPS

Dual output

14

Cross-Link Configuration

In the parallel configuration, the total critical load is


connected to one output bus. In situations where
there are two separate independent loads a
cross-link (or Q29) configuration can be used. As in
a parallel system the redundancy is N+1 over the
total amount of units, but during normal operation
the system acts as two independent parallel
systems. The redundancy however is shared
between the two systems and in case one of the
two parallel systems is overloaded closing the Q29
breaker will make use of the surplus of power
available in both of the systems. When in Q29
mode a output bus failure occurs it will be limited to
the bus causing the fault; the other system will be
disconnected by opening Q29.
Redundancy is only shared between critical loads;
non-critical loads do not have a cross-link
connection.
The cross-link therefore virtually eliminates single
points of failure in the bus-structure.
The limitations of the system are equal to that of a
parallel system.

AQ3
A1Q1

Critical load

A1Q2
AQ4

AQ6
A2Q1

A2Q2
AQ5

Non-critical load
(option)

Utility
Q29
B1Q1

B1Q2
BQ6

BQ5
B2Q1

Non-critical load
(option)

B2Q2
BQ4
Critical load
BQ3

Cross-link configuration

Systems configurations features:


Advantages
System configuration

Characteristics

Parallel Redundant (PR)

Simplest and most compact means of achieving


redundancy between UPS units and of
supporting very large or multiple loads.

Master - Slave (MS)

Eliminates a common UPS output bus-bar.

Cross - Link (CL)

Virtually eliminates the common output bus-bar.


On multi-UPS unit systems, far less UPS units
required to achieve required redundancy than in
an MS system.

Isolated - Parallel (IP)

No common output bus-bar due to additional tie


breakers and isolating chokes.
Efficient and flexible use of the system redundant
capacity.

Isolated - Redundant (IR)

No common output bus-bar due to separation of


loads and UPS unit outputs.
Fewer breakers and chokes required than in an
IP system.

Distributed Redundant (DR)

No common output bus-bar due to separation of


loads and UPS unit outputs.
Fewer breakers and chokes required than in an
IP system.
Efficient and flexible use of the system redundant
capacity.

Isolated Parallel System Configuration

Isolated Redundant Configuration

The isolated parallel system configuration


combines the fault-tolerance of redundant systems
with the load sharing capabilities of a parallel
system.

Traditionally, a parallel redundant configuration


would be used if redundancy were required. With
an isolated redundant configuration, redundancy is
created on the basis of standard single units.

The isolated parallel configuration connects multiple


units together, thereby creating redundancy, while
maintaining isolation between units at the same
time. Active power can then be shared between
units, while load faults will be kept isolated from
each other. A fault on one load will therefore not
influence other loads.

All individual units support their individual critical


loads. In an N+1 configuration, these systems
have one redundant unit as a backup. The backup
unit normally operates in a no-load condition. In the
event that one unit fails or is taken off-line, the
critical loads are automatically transferred to the
redundant unit (closing Q3A) via closed transition
instead of going to bypass.
Additionally, the non-critical load can be
connected to the redundant unit utilizing the
available UPS/CPS power. In case of maintenance
or failure of one module, the non-critical load will be
transferred back to the utility supply and your
critical load will be maintained.

Line interactive choke


1Q1

Isolated redundant configuration

1Q1

1Q2

1Q6

1Q5
Line interactive choke
2Q1

Line interactive choke

1Q5

2Q3B

2Q3A
Critical load A

Critical
load 2

2Q6

Non-critical load A

Non-critical
load 2

2Q5

Utility

3Q3B

Star
bus

3Q3A

3Q2

Critical load B

3Q6

Non-critical load B

Utility

Critical
load 3
Non-critical
load 3

Line interactive choke

Non-critical load C
(Optional)

2Q2

Star
bus

3Q1

3Q5

3Q5

Isolating choke

nQ2

nQ3
nQ6

nQ5

People to rely on

Non-critical
load 1

Isolating choke

3Q6

Power to rely on

1Q6

3Q2

3Q3

nQ1

Critical
load 1

2Q1

2Q5

1Q2

Utility

2Q2

2Q6

3Q1

Star
bus

Isolating choke

2Q3

Utility

1Q3

Isolating choke

1Q3

Redundant
bus-bar

Isolated parallel system configuration

Star
bus

All circuit breakers in this configuration need to be


rated to each units nominal output current. This
configuration can be used for much higher power
ratings as compared to the parallel redundant
configurations.

Critical
load n
Non-critical
load n

15

Distributed Redundant Configuration

QMS remote monitoring

In the isolated redundant configuration, the


redundant unit is normally supplementing a
non-critical load or running at no load at all. This
can be overcome with the distributed redundant
design.

Hitec Power Protection offers QMS, a powerful


software tool for the monitoring, supervision and
maintenance support of UPS/CPS systems. QMS
is a multi-purpose user-friendly software tool that
runs on a pc with Windows. The status, event
history and electrical parameters are gathered,
stored and conveniently arranged on the pc screen
for easy reading and printing.

Distributed redundant systems are normally


designed for N+1 redundancy. No single module
is assigned as a redundant unit. Instead, this role is
shared equally among all modules.
In the event of a single unit failure, its load will be
shared proportionately over the remaining units.
The load transfers are accomplished through
automatic transfer switches (ATS). The advantages
are the elimination of single point failures and equal
load sharing among all units.
Distributed redundant configuration
Redundant bus-bar
ABC
1Q3
1Q1

ATS

Critical
load A1

ATS

Critical
load A2

1Q2

Utility

1Q6

Monitoring your UPS/CPS systems at a glance with QMS software

Non-critical load A

1Q5

Easy access
2Q3
2Q1

ATS

Critical
load B1

ATS

Critical
load B2

2Q2

Utility

2Q6

The pc running the QMS software can be


connected to the UPS/CPS system either at site
through a dedicated serial link, remotely through a
modem connection, or over the Internet.

Non-critical load B

Detailed information

2Q5

3Q3
3Q1

ATS

Critical
load C1

ATS

Critical
load C2

3Q2

Utility

3Q6

The program provides detailed information on the


UPS/CPS status to make supervision easier.
Voltage and current readings, circuit breaker status,
operating hours, number of diesel starts, diesel
running time, and various other data are shown.

Non-critical load C

The software not only provides the user with real


time information but also provides a historical
overview of state changes and events over the last
half year. This overview is shown either as a list of
events, or as a mimic movie. The software is a
very powerful tool to help users and technicians
understand the UPS/CPS operation and thereby
greatly extends the operational, service and
maintenance possibilities of your UPS/CPS system.

3Q5

CPS

Dual output

Many of these readings can also be displayed as a


strip chart of events, which is especially useful
when viewing multi-module systems.

16

Installation & commissioning

Customer support

To install and commission a Hitec UPS/CPS system


is relatively easy and simple. It is very similar to
installing a standby generator.

The Hitec Power Protection name is synonymous


with reliability, quality and excellent service. We
believe that the best technology is only as good as
the service that supports it.

When comparing a UPS/CPS system to the


installation and commissioning of a battery UPS +
standby generator, a Hitec UPS/CPS eliminates the
installation of a battery UPS, batteries, harmonic
filters and all the inter-connecting electrical wiring
and synchronizing equipment.

We have therefore established a network of


qualified service organizations.

The main service organizations can


Provide Help Desk Services - available
24 x 7 x 365 - for operational questions, remote
monitoring / support, troubleshooting, etc.
Provide remote monitoring and diagnostic
support. Our service department can access
your UPS/CPS system through the Internet or a
modem connection, thus assisting with
operational issues, offering maintenance advice,
providing troubleshooting, etc.
Provide training programs at various skill levels
for the operation and maintenance of our
systems.
Rent containerized UPS/CPS units up to
1,000 kVA for disaster recovery, high-risk
maintenance periods, temporary power needs,
etc.

The power module comes pre-mounted on a


robust base frame. As an option, split frames can
be supplied to aid any site-specific difficulties
with lifting and installing.
Mounting engine exhaust, fuel and cooling
systems are identical to the installation works
required for a standby generator.
Room ventilation is similar for a Hitec UPS/CPS
system as for a standby generator.
The associated switchgear is standard
equipment, avoiding any special installation and
commissioning procedures.
The human machine interface provides easy and
clear access to all system parameters. It is a
powerful information tool for a simple & fast
commissioning of the UPS/CPS system.

We can arrange the


complete installation of
your UPS/CPS systems

Power to rely on

People to rely on

17

Technical specifications
Input:

Other:

Input voltage:

LV
MV

Voltage tolerance:
Power factor:

380...480 V 50/60 Hz
Up to 24 kV 50/60 Hz
+/- 10%
> 0.98

Color scheme:
RAL 7032 (Light Grey):
RAL 5012 (Blue):
Diesel engine:

Output:
Output voltage:

LV
MV

Voltage deviation:
Voltage asymmetry:
Harmonic distortion:
Harmonic filtering:
Frequency deviation:
Short circuit current:
Nominal power factor:

380...480 V 50/60 Hz
Up to 24 kV 50/60 Hz
+/- 1%
< 2%
< 3.5%
(with linear load)
> 95%
(in both directions)
< 0.5% ... 2.5%
Up to 14x
Nominal Current
0.8

Environmental (standard):
Degree of protection:
Operating altitude:
Ambient temperature:

IP21
(or higher as option)
< 150 m above
sea level
0...40 C (32 ... 104 F)

Options:
Remote monitoring via Internet or modem
connection
Other non-standard environmental conditions,
power ratings, voltages etc.
Silencing canopies
Medium voltage configurations
Containerized designs
Vibration monitoring
Bearing vibration monitoring

System:
Efficiency:
Crest factor:
RFI level:

Base frame & panels


Induction coupling
& generator
Manufacturers
standard

Up to 97%
3
Class A (EN 55.011)

Contact Hitec for other options

Some examples of available models


Max. output rating (kVA)
Type
UPS/CPS

Critical load

Approx. dimensions*

Critical + non-critical load


50 Hz

60 Hz

lxwxh

Approx.
weight)*

mm (inch)

kg (lbs)

50 Hz

60 Hz

600

500

600

1.000

1.200

5,900 x 1,600 x 2,100

8.000

(230 x 65 x 85)

(17.700)

1200

1.000

1.200

2.000

2.400

7,200 x 1,900 x 2,100

13.000

(285 x 75 x 85)

(28.700)

1800

1.700

1.800

2.250

2.500

8,600 x 1,900 x 2,400

21.500

(340 x 75 x 95)

(47.400)

2200

2.000

2.200

2.900

3.000

8,600 x 1,900 x 2,400

24.750

(340 x 75 x 95)

(54.600)

* Dimensions and weights for power module; excluding switchgear and control panel

All data in this brochure is for information and is subject to change without prior notice. No rights can be obtained from the contents of this brochure. Data provided in our offerings prevail at all times.

18

A global partner you can rely on


Hitec Power Protection has its worldwide head-

Our efforts begin with a thought out technical

quarters and production & test facilities in Almelo,

recommendation targeted to your power quality

The Netherlands.

and reliability need.

Our sales and service offices are in North America

If desired, we can take care of the complete electrical

(Houston, Texas), the UK (Birmingham), Spain

and mechanical installation and commissioning.

(Barcelona), China (Beijing), Dubai (U.A.E.) and

Our commitment continues with training, instruction

Singapore. We maintain a regional support office in

and maintenance. In case of emergency, our service

Taiwan, as well as numerous representatives and

organisation is 24x7 stand by to assist you with

agents strategically placed throughout the world.

your needs.

The Netherlands
Head office
Hitec Power Protection bv
Bedrijvenpark Twente 40
7602 KB Almelo
The Netherlands
Phone: +31 546 589 589
Fax:
+31 546 589 489
e-mail: [email protected]
web:
www.hitec-ups.com
United Kingdom
Hitec Power Protection Ltd.
Unit B21a
Holly Farm Business Park
Honiley, Kenilworth
Warwickshire, CV8 1NP
UK
Phone: +44 1926 48 45 35
Fax:
+44 1926 48 43 36
e-mail: [email protected]
web:
www.hitec-ups.com

Taiwan
Hitec Power Protection Taiwan Ltd.
5F-1, No. 27, Puding Rd.,
Hsinchu 300
Taiwan
Phone: +886 (03) 56 36 781
Fax:
+886 (03) 56 37 135
e-mail: [email protected]
www.hitec-ups.com
web:
China
Hitec Power Protection (Far East) B.V.
D-1016 C, Building Top Box, No. 69
Bei Chen West Street
Chaoyang District,
Beijing 100029
China
Phone: +86 10 58 77 20 36
Fax:
+86 10 58 77 20 37
e-mail: [email protected]
web:
www.hitec-ups.com
Singapore
Hitec Power Protection BV
Blk 3 Ang Mo Kio Industrial Park 2A
#02-06 AMK Tech I
Singapore 568050
Phone: +65 67 37 68 69
Fax:
+65 67 37 68 70
e-mail: [email protected]
web:
www.hitec-ups.com

United States of America


Hitec Power Protection Inc.
12502 Exchange Drive, Suite 404
Stafford, Texas 77477
USA
Phone: +1 (281) 240 - 5335
Fax:
+1 (281) 240 - 4774
e-mail: [email protected]
web:
www.hitecusa.com

Middle East & India


Hitec Power Protection bv
P.O. Box 50048
Dubai
U.A.E.
Phone: +971 434 737 00
Fax:
+971 434 732 32
e-mail: [email protected]
web:
www.hitec-ups.com

Spain
Hitec Power Protection Ibrica S.L
Pol. Ind. Moli den Serra
C/Alt Penedes nave 4
43710 Santa Oliva (Tarragona)
Spain
Phone: +34 977 668 902
+34 977 157 334
Fax:
e-mail: [email protected]
web:
www.hitec-ups.com

Malaysia
Hitec Power Protection (Malaysia) SDN BHD
TKT 3
Komplex MITC
Jalan Konvensyen
Ayer Keroh 75450
Melaka
Malaysia
Phone: +60 12 2789490
E-mail: [email protected]

You might also like