Solar System Sizing

This document provides guidance on sizing standalone solar photovoltaic power systems. It outlines a six step methodology: 1) estimate solar irradiation at the site, 2) collect system loads, 3) construct a load profile, 4) size battery capacity, 5) estimate output of a single PV module, and 6) size the PV array. Key factors include solar resource availability, load requirements, battery autonomy needs, and site location. Public databases and on-site measurements can provide solar data to estimate expected PV output.

Uploaded by

Doly Damanik
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
695 views10 pages

Solar System Sizing

This document provides guidance on sizing standalone solar photovoltaic power systems. It outlines a six step methodology: 1) estimate solar irradiation at the site, 2) collect system loads, 3) construct a load profile, 4) size battery capacity, 5) estimate output of a single PV module, and 6) size the PV array. Key factors include solar resource availability, load requirements, battery autonomy needs, and site location. Public databases and on-site measurements can provide solar data to estimate expected PV output.

Uploaded by

Doly Damanik
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

07/05/2016

SolarSystemSizingOpenElectrical

SolarSystemSizing
FromOpenElectrical

Contents
1Introduction
1.1Whydothecalculation?
1.2Whentodothecalculation?
2CalculationMethodology
2.1Step1:EstimateSolarIrradiationattheSite
2.1.1BaselineSolarIrradiationData
2.1.2SolarIrradiationonanInclinedPlane
2.1.3SolarTrackers
2.1.4NonStandardApplications
2.2Step2:CollecttheSolarPowerSystemLoads
2.3Step3:ConstructaLoadProfile
2.4Step4:BatteryCapacitySizing
2.5Step5:EstimateaSinglePVModule'sOutput
2.5.1EffectivePVCellTemperature
2.5.2StandardRegulator
2.5.3MPPTRegulator
2.6Step6:SizethePVArray
2.6.1StandardRegulator
2.6.2MPPTController
3WorkedExample
3.1Step1:EstimateSolarIrradiationattheSite
3.2Step2and3:CollectLoadsandConstructaLoadProfile
3.3Step4:BatteryCapacitySizing
3.4Step5:EstimateaSinglePVModule'sOutput
3.5Step6:SizethePVArray
4ComputerSoftware
5WhatNext?

Introduction
Thiscalculationoutlinesthesizingofastandalonesolarphotovoltaic(PV)powersystem.StandalonePV
systemsarecommonlyusedtosupplypowertosmall,remoteinstallations(e.g.telecoms)whereitisn't
practicalorcostefficienttorunatransmissionlineorhavealternativegenerationsuchasdieselgensets.
AlthoughthiscalculationisbiasedtowardsstandalonesolarPVsystems,itcanalsobeusedforhybrid
systemsthatdrawpowerfrommixedsources(e.g.commercialPV,hybridwindPVsystems,etc).Loads
mustbeadjustedaccordingtothedesiredamountthatthesolarPVsystemwillsupply.
http://www.openelectrical.org/wiki/index.php?title=Solar_System_Sizing

1/10

07/05/2016

SolarSystemSizingOpenElectrical

ThiscalculationisbasedoncrystallinesiliconPVtechnology.
TheresultsmaynotholdforothertypesofsolarPV
technologiesandthemanufacturer'srecommendationswillneed
tobeconsulted.

Whydothecalculation?
ThiscalculationshouldbedonewheneverasolarPVpower
systemisrequiredsothatthesystemisabletoadequatelycater
forthenecessaryloads.Theresultscanbeusedtodetermine
theratingsofthesystemcomponents(e.g.PVarray,batteries,
etc).

Whentodothecalculation?
Thefollowingprerequisiteinformationisrequiredbefore
performingthecalculation:
LoadsrequiredtobesupportedbythesolarPV
Figure1.SolarPVarray
system
Autonomytimeorminimumtolerabledowntime
(i.e.ifthereisnosun,howlongcanthesystembeoutofservice?)
GPScoordinatesofthesite(ormeasurementsofthesolarinsolationatthesite)
Outputvoltage(ACorDC)

CalculationMethodology
ThecalculationislooselybasedonAS/NZS4509.2(2002)
(http://infostore.saiglobal.com/store/Details.aspx?ProductID=315646)"StandalonepowersystemsSystem
designguidelines".Themethodologyhasthefollowingsixsteps:
Step1:Estimatethesolarirradiationavailableatthesite(basedonGPScoordinatesor
measurement)
Step2:Collecttheloadsthatwillbesupportedbythesystem
Step3:Constructaloadprofileandcalculatedesignloadanddesignenergy
Step4:Calculatetherequiredbatterycapacitybasedonthedesignloads
Step5:EstimatetheoutputofasinglePVmoduleattheproposedsitelocation
Step6:CalculatesizeofthePVarray

Step1:EstimateSolarIrradiationattheSite
Thefirststepistodeterminethesolarresourceavailabilityatthesite.Solarresourcesaretypically
discussedintermsofsolarradiation,whichismoreorlessthecatchalltermforsunlightshiningona
surface.Solarradiationconsistsofthreemaincomponents:
Directorbeamradiationismadeupofbeamsofunscatteredandunreflectedlightreaching
thesurfaceinastraightlinedirectlyfromthesun
Diffuseradiationisscatteredlightreachingthesurfacefromthewholesky(butnotdirectly
http://www.openelectrical.org/wiki/index.php?title=Solar_System_Sizing

2/10

07/05/2016

SolarSystemSizingOpenElectrical

fromthesun)
Albedoradiationisislight
reflectedontothesurface
fromtheground
Solarradiationcanbequantitatively
measuredbyirradianceandirradiation.
Notethatthetermsaredistinct
"irradiance"referstothedensityofthe
powerthatfallsonasurface(W/m2)
and"irradiation"isthedensityofthe
energythatfallsonasurfaceoversome
periodoftimesuchasanhouroraday
(e.g.Wh/m2perhour/day).

Figure2.Worldsolarirradiationmap

Inthissection,wewillestimatethesolarradiationavailableatthesitebasedondatacollectedinthepast.
However,itneedstobestressedthatsolarradiationisstatisticallyrandominnatureandthereisinherent
uncertaintyinusingpastdatatopredictfutureirradiation.Therefore,wewillneedtobuildindesign
marginssothatthesystemisrobusttopredictionerror.
BaselineSolarIrradiationData
Theeasiestoptionistoestimatethesolarirradiation(orsolarinsolation)byinputtingtheGPScoordinates
ofthesiteintotheNASASurfaceMeteorologyandSolarResource(http://eosweb.larc.nasa.gov/cgi
bin/sse/sse.cgi)website.
ForanygivensetofGPScoordinates,thewebsiteprovidesfirstpassestimatesofthemonthlyminimum,
averageandmaximumsolarirradiation(inkWh/m2/day)atgroundlevelandatvarioustiltangles.Collect
thisdata,chooseanappropriatetiltangleandidentifythebestandworstmonthsoftheyearintermsof
solarirradiation.Alternatively,forUSlocationsdatafromtheNationalSolarRadiationDatabase
(http://www.nrel.gov/rredc/solar_data.html)canbeused.
Theminimum,averageandmaximumdaytimetemperaturesatthesitecanalsobedeterminedfromthe
publicdatabaseslistedabove.ThesetemperatureswillbeusedlaterwhencalculatingtheeffectivePVcell
temperature.
Actualsolarirradiationmeasurementscanalsobemadeatthesite.Providedthatthemeasurementsare
takenoveralongenoughperiod(orcrossreferenced/combinedwithpublicdata),thenthemeasurements
wouldprovideamoreaccurateestimateofthesolarirradiationatthesiteastheywouldcapturesitespecific
characteristics,e.g.anyobstructionstosolarradiationsuchaslargebuildings,trees,mountains,etc.
SolarIrradiationonanInclinedPlane
MostPVarraysareinstalledsuchthattheyfacetheequatorataninclinetothehorizontal(formaximum
solarcollection).Theamountofsolarirradiationcollectedoninclinedsurfacesisdifferenttotheamount
collectedonahorizontalsurface.Itistheoreticallypossibletoaccuratelyestimatethesolarirradiationon
anyinclinedsurfacegiventhesolarirradiationonanhorizontalplaneandthetiltangle(therearenumerous
researchpapersonthistopic,forexampletheworkdonebyLiuandJordanin1960).
http://www.openelectrical.org/wiki/index.php?title=Solar_System_Sizing

3/10

07/05/2016

SolarSystemSizingOpenElectrical

However,forthepracticalpurposeofdesigningasolarPVsystem,we'llonlylookatestimatingthesolar
irradiationattheoptimaltiltangle,whichistheinclinethatcollectsthemostsolarirradiation.Theoptimal
tiltanglelargelydependsonthelatitudeofthesite.Atgreaterlatitudes,theoptimaltiltangleishigherasit
favourssummertimeradiationcollectionoverwintertimecollection.TheHandbookofPhotovoltaicScience
andEngineering(http://www.amazon.com/HandbookPhotovoltaicScienceEngineering
Antonio/dp/0471491969)suggestsalinearapproximationtocalculatingtheoptimaltiltangle:

Where

istheoptimaltiltangle(deg)
isthelatitudeofthesite(deg)

Thehandbookalsosuggestsapolynomialapproximationforthesolarirradiationattheoptimaltiltangle:

Where

isthesolarirradiationonasurfaceattheoptimaltiltangle(Wh/m2)
isthesolarirradiationonthehorizontalplane(Wh/m2)
istheoptimaltiltangle(deg)

Alternatively,theestimatedirradiationdataontiltedplanescanbesourceddirectlyfromthevariouspublic
databaseslistedabove.
SolarTrackers
Solartrackersaremechanicaldevicesthatcantrackthepositionofthesunthroughoutthedayandorient
thePVarrayaccordingly.Theuseoftrackerscansignificantlyincreasethesolarirradiationcollectedbya
surface.Solartrackerstypicallyincreaseirradiationby1.2to1.4times(for1axistrackers)and1.3to1.5
times(for2axistrackers)comparedtoafixedsurfaceattheoptimaltiltangle.
NonStandardApplications
Asolarirradiationlossfactorshouldbeusedforapplicationswheretherearehightiltangles(e.g.vertical
PVarraysaspartofabuildingfacade)orverylowtiltangles(e.g.NorthSouthhorizontaltrackers).Thisis
becausethethesolarirradiationissignificantlyaffected(detrimentally)whentheangleofincidenceishigh
orthesolarradiationismainlydiffuse(i.e.noalbedoeffectsfromgroundreflections).Formoredetailson
thislossfactor,consultthestandardASHRAE93,"Methodsoftestingtodeterminethethermal
performanceofsolarcollectors"(http://www.techstreet.com/standards/ASHRAE/93_2010?
product_id=1703551).

Step2:CollecttheSolarPowerSystemLoads
Thenextstepistodeterminethetypeandquantityofloadsthatthesolarpowersystemneedstosupport.
http://www.openelectrical.org/wiki/index.php?title=Solar_System_Sizing

4/10

07/05/2016

SolarSystemSizingOpenElectrical

Forremoteindustrialapplications,suchasmeteringstations,theloadsarenormallyforcontrolsystemsand
instrumentationequipment.Forcommercialapplications,suchastelecommunications,theloadsarethe
telecomshardwareandpossiblysomesmallarealightingformaintenance.Forruralelectrificationand
residentialapplications,theloadsaretypicallydomesticlightingandlowpoweredapppliances,e.g.
computers,radios,smalltv's,etc.

Step3:ConstructaLoadProfile
RefertotheLoadProfileCalculationfordetailsonhowtoconstructaloadprofileandcalculatethedesign
load(
)anddesignenergy(
).Typically,the"24HourProfile"methodforconstructingaloadprofile
isusedforSolarPowerSystems.

Step4:BatteryCapacitySizing
InasolarPVpowersystem,thebatteryisusedtoprovidebackupenergystorageandalsotomaintain
outputvoltagestability.RefertotheBatterySizingCalculationfordetailsonhowtosizethebatteryforthe
solarpowersystem.

Step5:EstimateaSinglePVModule'sOutput
ItisassumedthataspecificPVmoduletype(e.gSuntechSTP070S12Bb)hasbeenselectedandthe
followingparameterscollected:
Peakmodulepower,
(Wp)
Nominalvoltage
(Vdc)
Opencircuitvoltage
(Vdc)
Optimumoperatingvoltage
(Vdc)
Shortcircuitcurrent
(A)
Optimumoperatingcurrent
(A)
Peakpowertemperaturecoefficient (%perdegC)
Manufacturer'spoweroutputtolerance
(%)
ManufacturersusuallyquotethesePVmoduleparametersbasedonStandardTestConditions(STC):an
irradianceof1,000W/m2,thestandardreferencespectralirradiancewithAirMass1.5(seetheNRELsite
(http://rredc.nrel.gov/solar/spectra/am1.5/)formoredetails)andacelltemperatureof25degC.Standard
testconditionsrarelyprevailonsiteandwhenthePVmoduleareinstalledinthefield,theoutputmustbe
deratedaccordingly.
EffectivePVCellTemperature
Firstly,theaverageeffectivePVcelltemperatureattheinstallationsiteneedstobecalculated(asitwillbe
usedinthesubsequentcalculations).ItcanbeestimatedforeachmonthusingAS\NZS4509.2equation
3.4.3.7:

http://www.openelectrical.org/wiki/index.php?title=Solar_System_Sizing

5/10

07/05/2016

Where

SolarSystemSizingOpenElectrical

istheaverageeffectivePVcelltemperature(degC)
istheaveragedaytimeambienttemperatureatthesite(degC)

StandardRegulator
Forasolarpowersystemusingastandardswitchedchargeregulator/controller,thederatedpoweroutput
ofthePVmodulecanbecalculatedusingAS\NZS4509.2equation3.4.3.9(1):

Where
(W)

isthederatedpoweroutputofthePVmoduleusingastandardswitchedchargecontroller
isthedailyaverageoperatingvoltage(Vdc)
isthemoduleoutputcurrentbasedonthedailyaverageoperatingvoltage,attheeffective
averagecelltemperatureandsolarirradianceatthesitemoreonthisbelow(A)
isthemanufacturer'spoweroutputtolerance(pu)
isthederatingfactorfordirt/soiling(Clean:1.0,Low:0.98,Med:0.97,High:0.92)

Toestimate
,youwillneedtheIVcharacteristiccurveofthePVmoduleattheeffectivecell
temperaturecalculatedabove.Foraswitchedregulator,theaveragePVmoduleoperatingvoltageis
generallyequaltotheaveragebatteryvoltagelessvoltagedropsacrossthecablesandregulator.
MPPTRegulator
ForasolarpowersystemusingaMaximumPowerPointTracking(MPPT)chargeregulator/controller,the
deratedpoweroutputofthePVmodulecanbecalculatedusingAS\NZS4509.2equation3.4.3.9(2):

Where

isthederatedpoweroutputofthePVmoduleusinganMPPTchargecontroller(W)
isthenominalmodulepowerunderstandardtestconditions(W)
isthemanufacturer'spoweroutputtolerance(pu)
isthederatingfactorfordirt/soiling(Clean:1.0,Low:0.98,Med:0.97,High:0.92)
isthetemperaturederatingfactorseebelow(pu)

ThetemperaturederatingfactorisdeterminedfromAS\NZS4509.2equation3.4.3.9(1):

Where

istemperaturederatingfactor(pu)
isthePowerTemperatureCoefficient(%perdegC)
istheaverageeffectivePVcelltemperature(degC)

http://www.openelectrical.org/wiki/index.php?title=Solar_System_Sizing

6/10

07/05/2016

SolarSystemSizingOpenElectrical

isthetemperatureunderstandardtestconditions(typically25degC)

Step6:SizethePVArray
ThesizingofthePVarraydescribedbelowisbasedonthemethodoutlinedinAS/NZS4509.2.Thereare
alternativesizingmethodologies,forexamplethemethodbasedonreliabilityintermsoflossofload
probability(LLP),butthesemethodswillnotbefurtherelaboratedinthisarticle.Thefactthatthereisno
commonlyacceptedsizingmethodologyreflectsthedifficultyofperformingwhatisaninherentlyuncertain
task(i.e.apredictionexercisewithmanyrandomfactorsinvolved).
StandardRegulator
ThenumberofPVmodulesrequiredforthePVarraycanbefoundbyusingAS\NZS4509.2equation
3.4.3.11(1):

Where

isthenumberofPVmodulesrequired
isthederatedpoweroutputofthePVmodule(W)
isthetotaldesigndailyenergy(VAh)
istheoversupplycoefficient(pu)
isthesolarirradiationafterallfactors(e.g.tiltangle,tracking,etc)havebeencaptured
(kWh/m2/day)
isthecoulombicefficiencyofthebattery(pu)

Theoversupplycoefficient isadesigncontingencyfactortocapturetheuncertaintyindesigningsolar
powersystemswherefuturesolarirradiationisnotdeterministic.AS/NZS4509.2Table1recommends
oversupplycoefficientsofbetween1.3and2.0.
Abatterycoulombicefficiencyofapproximately95%wouldbetypicallyused.
MPPTController
ThenumberofPVmodulesrequiredforthePVarraycanbefoundbyusingAS\NZS4509.2equation
3.4.3.11(2):

Where

isthenumberofPVmodulesrequired
isthederatedpoweroutputofthePVmodule(W)
isthetotaldesigndailyenergy(VAh)
istheoversupplycoefficient(pu)

http://www.openelectrical.org/wiki/index.php?title=Solar_System_Sizing

7/10

07/05/2016

SolarSystemSizingOpenElectrical

isthesolarirradiationafterallfactors(e.g.tiltangle,tracking,etc)havebeencaptured
(kWh/m2/day)
istheefficiencyofthePVsubsystem(pu)
Theoversupplycoefficient isadesigncontingencyfactortocapturetheuncertaintyindesigningsolar
powersystemswherefuturesolarirradiationisnotdeterministic.AS/NZS4509.2Table1recommends
oversupplycoefficientsofbetween1.3and2.0.
TheefficiencyofthePVsubsystem
isthecombinedefficienciesofthechargeregulator/controller,
batteryandtransmissionthroughthecablebetweenthePVarrayandthebattery.Thiswilldependon
specificcircumstances(forexample,thePVarrayalargedistancefromthebattery),thoughanefficiencyof
around90%wouldbetypicallyused.

WorkedExample
Asmallstandalonesolarpowersystemwillbedesignedforatelecommunicationsoutpostlocatedinthe
desert.

Step1:EstimateSolarIrradiationattheSite
Fromsitemeasurements,thesolarirradiationatthesiteduringtheworstmonthattheoptimaltitleangleis
4.05kWh/m2/day.

Step2and3:CollectLoadsandConstructaLoadProfile
Forthisexample,weshallusethesame
loadsandloadprofiledetailedinthe
EnergyLoadProfileCalculationexample.
Theloadprofileisshowninthefigure
rightandthefollowingquantitieswere
calculated:
DesignloadSd=768VA
DesignenergydemandEd=
3,216VAh

Step4:BatteryCapacitySizing
Forthisexample,weshallusethesame
batterysizescalculatedintheBattery
SizingCalculation]workedexample.The
selectednumberofcellsinseriesis62
cellsandtheminimumbatterycapacityis
44.4Ah.

Figure3.Loadprofileforthisexample

Step5:EstimateaSinglePVModule'sOutput
http://www.openelectrical.org/wiki/index.php?title=Solar_System_Sizing

8/10

07/05/2016

SolarSystemSizingOpenElectrical

APVmodulewiththefollowingcharacteristicsischosen:
Peakmodulepower,
Wp
Nominalvoltage
Vdc
Peakpowertemperaturecoefficient
Manufacturer'spoweroutputtolerance

%perdegC
%

Supposetheaveragedaytimeambienttemperatureis40C.TheeffectivePVcelltemperatureis:

degC
AnMPPTcontrollerwillbeused.Thetemperaturederatingfactoristherefore:

Givenamediumdirtderatingfactorof0.97,thederatedpoweroutputofthePVmoduleis:

Step6:SizethePVArray
Givenanoversupplycoefficientof1.1andaPVsubsystemefficiencyof85%,thenumberofPVmodules
requiredforthePVarrayforaMPPTregulatoris:

10.9588modules
ForthisPVarray,12modulesareselected.

ComputerSoftware
ItisrecommendedthatthesolarPVsystemsizedinthiscalculationissimulatedwithcomputersoftware.
Forexample,HOMER(http://www.homerenergy.com/)isapopularsoftwarepackageforsimulatingand
optimisingadistributedgeneration(DG)systemoriginallydevelopedbytheNationalRenewableEnergy
Laboratory(NREL).
ScreenshotsfromHOMERsoftware

http://www.openelectrical.org/wiki/index.php?title=Solar_System_Sizing

9/10

07/05/2016

SolarSystemSizingOpenElectrical

PVOutput

BatteryOutput

WhatNext?
Withthesizingcalculationcompleted,thesolarPVequipment(PVarray,batteries,chargecontrollers,etc)
canbespecifiedandacostestimateorbudgetenquiry/requisitionpackageissued.Theapproximate
dimensionsoftheequipment(especiallythePVarrayandbatteries)canalsobeestimatedandadesign
layoutcanbeproduced.