Smart Line Level Tool
Smart Line Level Tool
Technical Information
Repeatability 1mm
0.4 to 50 m range
(optional)
o
Modular design
Figure 2 - Inserting tank specific details into Application and Validation Tool.
Description
The SmartLine Guided Wave Radar Level transmitter
utilizes Time Domain Reflectometry (TDR) technology
which is proven to be effective for a majority of level
measuring applications.
Modular Design
Configuration Tools
Diagnostics
SmartLine transmitters all offer digitally accessible
diagnostics which aid in providing advanced warning of
possible failure events minimizing unplanned shutdowns,
providing lower overall operational costs
System Integration
o
Transmitter messaging
Tamper reporting
General Specifications
Parameter
Description
Measurable media
Measurements performed
Vertical and horizontal cylinders, rectangular tanks, spheres, stilling / bypass wells
SIL certification
SIL 2/3
Measuring range
Liquids
Wetted materials
Material
Min Temp
Max Temp
Viton or Fluorocarbon
-26 degC
200 deg C
-40 degC
150 deg C
-20 degC
Buna-N
-40 degC
120 degC
Metallic - 17-4 PH
-60 degC
450 degC
-60 degC
450 degC
User Interface
3 button keypad
Display
Output Units
Level
Percentage Level
Distance to Level
Level Rate
Volume
Distance to Interface
Interface Level
% Interface Level
Lower Volume
Upper Volume
Language
Electrical Connections
Wiring
Mounting
Dimensions
Net Weight
Rated Condition
Operative Limits
-40 to 85
-40 to 185
-40 to 85
-40 to 185
-55 to 120
-67 to 248
SLG 720
-40 to 200
-40 to 392
-40 to 200
-40 to 392
-55 to 125
-67 to 257
SLG 726
-60 to 450
-76 to 842
-60 to 450
-76 to 842
-55 to 125
-67 to 257
Ambient Temperature1
Transportation and
Storage
Process Connector2
Humidity
%RH
0 to 100
0 to 100
Voltage at HART terminal is 14.0 to 42.0 Vdc (IS versions limited to 30 Vdc)
0 to 100
(HART)
-)
1 LCD Display operating temperature -20C to +70C . Storage temperature -30C to 80C.
2 rated Condition and Operative Limit temperatures subject to O-Ring selection and ambient temperature conditions. See Error! Reference source not found.
or details.
3 Units can withstand overpressure of 1.5 x MAWP without damage
4 Consult factory for MAWP of SLG 700 transmitter with CRN approval
Analog Output
Digital Communications:
Honeywell Standard:
3.8 20.8 mA
3.6 mA and 21.0 mA
Normal Limits:
Failure Mode:
Span
Resolution
1 mm (0.04 inch)
Accuracy
Reference conditions are
given in the table below
NAMUR NE 43 Compliance:
3.8 20.5 mA
3.6 mA and 21.0 mA
Repeatability
1 mm (0.04 inch)
1.4
Electromagnetic Compatibility
Reference Conditions
Parameter
Ambient Temperature
Process Temperature
Humidity
Flange diameter for rod, wire configurations
Reference product in the
Single
tank
Two (non-flooded)
Minimum distance to walls and obstacles
Process pressure
Unit
C
C
% RH
mm
NA
NA
mm
kPa
Reference Condition
25 1
25 1
0 - 85
>300
Air / Water
Air / Oil (DC=2) / Water
400
100 10
Probe
Type
Materials
Rod
SS 316L, C-276
Wire
SS 316
Coax
SS 316L, C-276
Range (m)
1.4
15
1.8
25
42
46
50
Centering Disk
Parameter
Min DC
Range (m)
Min DC
Range (m)
1.4
6.3
1.4
6.3
Description
Type
Centering Disk
Materials
SS 316L, C-276
MAX PRESSURE
[bar]
-30
-20
-10
10
20
30
40
50
60
70
80
85
-60
400
400
400
400
400
400
400
400
375
375
350
350
325
325
-50
400
400
400
400
400
400
400
400
375
375
350
350
325
325
400
400
400
400
400
400
400
375
375
350
350
325
325
300
50
400
400
400
400
400
400
400
375
375
350
350
325
300
300
100
400
400
400
400
400
400
375
375
350
350
325
325
300
150
400
400
400
400
400
400
375
375
350
350
325
325
300
200
400
400
400
400
400
375
375
350
350
325
325
300
250
400
400
400
400
400
375
375
350
350
325
325
300
300
400
400
400
400
375
375
350
350
325
325
300
300
350
400
400
400
400
375
375
350
350
325
325
300
400
400
400
400
375
375
350
350
325
325
300
300
450
400
400
400
375
375
350
350
325
325
300
300
NON-(IS)
Figure 7 - SLG 726 Maximum pressure based on maximum operating temperature in tabular form
10
Schedule Entries
45 maximum schedule entries
Power Supply
50 maximum Links
Software Download
Utilizes Class-3 of the Common Software Download
procedure as per FF-883 which allows the field devices of
host.
Standard Diagnostics
Qty
Execution Time
Resource
1P
NA/a
Level Transducer
1P
NA
1P
NA
Diagnostic
1P
NA
LCD Display
1P
NA
Analog Input
1P 5I
30 ms
PID w/Autotune
1P 1I
45 ms
Arithmetic
1P 1I
30 ms
Input Selector
1P 1I
30 ms
P = Permanent Block
I = Instantiable Block
CE Mark
11
Approval Certifications:
AGENCY
TYPE OF PROTECTION
CSA
cCSAus
(Canada and
USA)
COMM.
OPTION
All
FIELD
PARAMETERS
AMBIENT TEMP
(Ta)
Note 1
-50 C to 85 C
4-20 mA / HART
Note 2a
-50 C to 70 C
FOUNDATION
Fieldbus / FISCO
Note 2b/2c
4-20 mA / HART
Note 1
-50 C to 85 C
FOUNDATION
Fieldbus / FISCO
Note 1
-50 C to 85 C
All
All
-50 C to 70 C
All SLG 700 models are registered in all provinces and territories
in Canada.
All
Note 1
-50 C to 85 C
4-20 mA / HART
Note 2
-50 C to 70 C
FOUNDATION
Fieldbus / FISCO
Note 2
4-20 mA / HART
Note 1
-50 C to 85 C
FOUNDATION
Fieldbus / FISCO
Note 1
-50 C to 85 C
All
All
-50 C to 70 C
12
Note 1
-50 C to 85 C
4-20 mA / HART
Note 2a
-50 C to 70 C
FOUNDATION
Fieldbus / FISCO
Note 2b/2c
4-20 mA / HART
Note 1
-50 C to 85 C
FOUNDATION
Fieldbus / FISCO
Note 1
-50 C to 85 C
All
All
All
Intrinsically Safe:
II 1 G Ex ia IIC T4 Ga
Nonincendive with IS output:
3[1] G Ex nA[ia] IIC t4 Gb[Ga]
IECEx
(World)
SAEx
(South Africa)
KOSHA
(Korea)
-50 C to 85 C
4-20 mA / HART
Note 2a
-50 C to 70 C
FOUNDATION
Fieldbus / FISCO
Note 2b/2c
-50 C to 70 C
4-20 mA / HART
Note 1
-50 C to 85 C
FOUNDATION
Fieldbus / FISCO
Note 1
-50 C to 85 C
All
All
All
Intrinsically Safe:
Ex ia IIC T4 Ga
Intrinsically Safe:
Ex ia IIC T4 Ga
Nonincendive with IS output:
Ex nA[ia] IIC T4 Gc[Ga]
Enclosure: IP66/ IP67
(Future
Certifications)
INMETRO
-50 C to 70 C
Note 1
CCoE
(India)
All
Note 1
-50 C to 85 C
4-20 mA / HART
Note 2a
-50 C to 70 C
FOUNDATION
Fieldbus
Note 2b
-50 C to 70 C
4-20 mA / HART
Note 1
-50 C to 85 C
FOUNDATION
Fieldbus
Note 1
-50 C to 85 C
All
All
(Brazil)
GOST
(Russia)
Intrinsically Safe:
Ex ia IIC T4 Ga
Nonincendive with IS output:
Ex nA[ia] IIC T4 Gc[Ga]
Enclosure : IP 66/67
Note 1
-50 C to 85 C
4-20 mA / HART
Note 2a
-50 C to 70 C
FOUNDATION
Fieldbus
Note 2b
-50 C to 70 C
4-20 mA / HART
Note 1
-50 C to 85 C
FOUNDATION
Fieldbus
Note 1
All
All
-50 C to 85 C
-
13
Intrinsically Safe:
Ex ia IIC T4 Ga
Nonincendive with IS output:
Ex nA[ia] IIC T4 Ga/Gc
Enclosure : IP 66/67
Notes:
1.
2.
All
Note 1
-50 C to 85 C
4-20 mA / HART
Note 2a
-50 C to 70 C
FOUNDATION
Fieldbus
Note 2b
-50 C to 70 C
4-20 mA / HART
Note 1
-50 C to 85 C
FOUNDATION
Fieldbus
Note 1
-50 C to 85 C
All
All
Operating Parameters:
Voltage= 14.0 to 42.0 V DC (HART)
Current= 4-20 mA Normal (3.5 23 mA Faults) (HART)
= 9 to 32 V (FF)
= 29.4 mA Max (FF)
Intrinsically Safe Entity Parameters
a. Analog/ HART Entity Values:
Vmax= Ui = 30 V
Imax= Ii= 225 mA
Ci = 4 nF
Li = 0
Pi =0.9 W
b. Foundation Fieldbus- Entity Values
Vmax= Ui = 30 V
Imax= Ii= 225 mA
Ci = 0 nF
Li = 0
Pi =1.0 W
c. Foundation Fieldbus (FISCO)- Entity Values
Vmax= Ui = 17.5 V
Imax= Ii= 380 mA
Ci = 0 nF
Li = 0
Pi =5.32 W
When Installed as FISCO Ta= -50C to 45C
Overfill Protection
WHG
Certificate #: Z-65.16-556. TV-tested and approved for overfill protection according to the German WHG
regulations
IEC 61508 SIL 2 for non-redundant use and SIL 3 for redundant use according to EXIDA and TV Nord Sys
Tec GmbH & Co. KG under the following standards: IEC61508-1: 2010; IEC 61508-2: 2010; IEC61508-3: 2010.
Note: Only transmitters with SIL markings are certified for SIL applications. Transmitters ordered with SIL
certification will signify the SIL Level on the SLG700 Nameplate.
14
Reference Dimensions:
millimeters
inches
Figure 9 -SLG720 SmartLine Level with BSP (British Standard Pipe) fitting
15
16
Figure 11 - SmartLine Level with remote housing option (Shown with SLG720)
17
18
19
20
21
22
23
Model Selection Guides are subject to change and are inserted into the specifications as guidance only.
Prior to specifying or ordering a model please check for the latest revision of the Model Selection Guides which are
published at: www.honeywellprocess.com/en-US/pages/default.aspx
Select the desired Key Number. The arrow to the right marks the selection available.
Make one selection from each Table (I, II and IX) using the column below the proper arrow.
SLG72 _
II
_____________
III
____
VI
VII
_____
- _ -
___
IV
___
VIII (Optional)
__,__
Application
KEY NUMBER
Selection
SLG720
High Temperature/High Pressure Liquid Level Measurement (-60 to 450C/-1 to 400 bar)
SLG726
Availability
Measurement
Min/Max Length
Meters (Feet)
316/316L
General Liquids
a. Wetted materials
and probe type
Alloy C-276
000_________ _
SRA _ _ _ _ _ _ _ _ _ _
SRB _ _ _ _ _ _ _ _ _ _
SRC _ _ _ _ _ _ _ _ _ _
SRH _ _ _ _ _ _ _ _ _ _
SRJ _ _ _ _ _ _ _ _ _ _
SRM _ _ _ _ _ _ _ _ _ _
SRN _ _ _ _ _ _ _ _ _ _
SRK _ _ _ _ _ _ _ _ _ _
SRL _ _ _ _ _ _ _ _ _ _
SWA _ _ _ _ _ _ _ _ _ _
SWB _ _ _ _ _ _ _ _ _ _
SCA _ _ _ _ _ _ _ _ _ _
SCB _ _ _ _ _ _ _ _ _ _
ARA _ _ _ _ _ _ _ _ _ _
ARD _ _ _ _ _ _ _ _ _ _
ARE _ _ _ _ _ _ _ _ _ _
ACA _ _ _ _ _ _ _ _ _ _
316/316L
c. Centering Disk
Alloy C-276
2" Centering
3" Centering
4" Centering
6" Centering
8" Centering
2" Centering
3" Centering
4" Centering
6" Centering
8" Centering
None
Weight
None
Disk (see
Disk (see
Disk (see
Disk (see
Disk (see
Disk (see
Disk (see
Disk (see
Disk (see
Disk (see
Note
Note
Note
Note
Note
Note
Note
Note
Note
Note
2
2
2
2
2
2
2
2
2
2
below)
below)
below)
below)
below)
below)
below)
below)
below)
below)
d. Seal material
Liquids
TABLE I (con't)
Selection
_____
TABLE I
b. Probe End
Treatment
IX
400 mm to 50000 mm (in 100 mm increments) (Probe length 00000 available only with table 1A selection 000.)
Selection
20
26
___N_________
___W_________
____00_______
____S2_______
____S3_______
____S4_______
____S6_______
____S8_______
_ _ _ _ A2 _ _ _ _ _ _ _
_ _ _ _ A3 _ _ _ _ _ _ _
_ _ _ _ A4 _ _ _ _ _ _ _
_ _ _ _ A6 _ _ _ _ _ _ _
_ _ _ _ A8 _ _ _ _ _ _ _
_ _ _ _ _ _ V_ _ _ _ _ _
______K______
______E______
______B______
_ _ _ _ _ _ M_ _ _ _ _ _
______N______
u
p
q
q
q
q
q
y
y
y
y
y
u
p
q
q
q
q
q
_ _ _ _ _ _ _ M_ _ _ _ _
_ _ _ _ _ _ _ _ XXXXX
Note: All flanges are 316L; when coated or C-276 wetted materials are selected a wetted material barrier is provided.
Note 2: A drilling jig needs to be ordered when ordering centering disk for rod probes. See accessory part numbers for drilling jig part.
Note 3: For transmitters with threaded process connections and probe lengths over 2000mm, probe will need to be assembled from within the tank.
24
TABLE II
Connection Types
Material
Size
1-1/2"
2"
3"
316/316L
Flanges
ANSI B16.5 (CRN)
4"
6"
8"
1-1/2"
C-276
2"
3"
DN40
DN50
316/316L
DN80
Flanges
DIN EN 1092
DN100
DN150
DN200
DN40
DN50
C-276
DN80
DN100
Flanges
Special
316/316L
316/316L
Threaded
Fittings
ISO228 and ANS
C-276
Fisher 249B/259B
Fisher 249C
Masoneilan 7-1/2"
Rating
Selection
20
Class 150lb RF
Class 300lb RF
Class 150lb RF
Class 300lb RF
Class 600lb RF
Class 900lb RF
Class 1500lb RF
Class 600lb RTJ
Class 900lb RTJ
Class 1500lb RTJ
Class 150lb RF
Class 300lb RF
Class 600lb RF
Class 900lb RF
Class 1500lb RF
Class 600lb RTJ
Class 900lb RTJ
Class 1500lb RTJ
Class 150lb RF
Class 300lb RF
Class 600lb RF
Class 900lb RF
Class 1500lb RF
Class 600lb RTJ
Class 900lb RTJ
Class 1500lb RTJ
Class 150lb RF
Class 150lb RF
Class 150lb RF
Class 300lb RF
Class 150lb RF
Class 300lb RF
Class 150lb RF
Class 300lb RF
DN40 PN10-40
DN50 PN10/16
DN50 PN25/40
DN50 PN63
DN50 PN100
DN50 PN160
DN50 PN250
DN80 PN10/16
DN80 PN25/40
DN80 PN63
DN80 PN100
DN80 PN160
DN80 PN250
DN100 PN10/16
DN100 PN25/40
DN100 PN63
DN100 PN100
DN100 PN160
DN100 PN250
DN150 PN10/16
DN200 PN16
DN40 PN10/40
DN50 PN10/16
DN50 PN25/40
DN80 PN10/16
DN80 PN25/40
DN100 PN10/16
DN100 PN25/40
600lb
600lb
600 psi
3/4" NPT (CRN)
1" NPT (CRN)
1 - 1/2" NPT (CRN)
2" NPT (CRN)
3/4" BSP (G 3/4")
1" BSP (G 1")
1-1/2" BSP/G 1-1/2
3/4" NPT (CRN)
1" NPT (CRN)
1 - 1/2" NPT (CRN)
2" NPT (CRN)
3/4" BSP (G 3/4")
1" BSP (G 1")
1-1/2" BSP/G 1-1/2
AS1A
AS1B
AS2A
AS2B
AS2C
AS2D
AS2H
AS2J
AS2K
AS2L
AS3A
AS3B
AS3C
AS3D
AS3H
AS3J
AS3K
AS3L
AS4A
AS4B
AS4C
AS4D
AS4H
AS4J
AS4K
AS4L
AS6A
AS8A
AC1A
AC1B
AC2A
AC2B
AC3A
AC3B
DS4A
DS5A
DS5B
DS5H
DS5J
DS5K
DS5L
DS8A
DS8B
DS8H
DS8J
DS8K
DS8L
DS1A
DS1B
DS1H
DS1J
DS1K
DS1L
DS1Y
DS2A
DC4C
DC5A
DC5B
DC8A
DC8B
DC1A
DC1B
FS1C
FS1D
MS1C
NS7A
NS1A
NS5A
NS2A
GS7A
GS1A
GS5A
NC7A
NC1A
NC5A
NC2A
GC7A
GC1A
GC5A
26
TABLE III
Approvals
25
26
A_ _
B__
C__
D__
E__
F__
G__
H__
J__
K__
L__
M_ _
_H_
_F_
__0
__A
__D
__E
Selection
20
26
1____
_0___
_1___
_2___
__0__
_ _ _1 _
_ __ 2_
_ __ 3_
_ __ 4_
_ _ _5_
_ _ _6_
f
f
f
f
f
f
f
f
g
g
g
g
____ S
____ C
A
B
Selection
0__
1__
2__
_ A0
_ A2
_ A6
_ A7
_ A8
_ A9
n
n
m
n
m
n
n
m
n
m
01
02
03
04
Selection
_____
00000
TABLE IV
Connection
Lightning Protection
1/2 NPT
M20
1/2 NPT
M20
1/2 NPT
M20
1/2 NPT
M20
1/2 NPT
M20
1/2 NPT
M20
None
None
Yes
Yes
None
None
Yes
Yes
None
None
Yes
Yes
a. Electronic Housing
Material &
Connection Type
Digital Protocol
4-20mA dc
n/a
HART Protocol
Foundation Fieldbus
b. Output/ Protocol
c. Customer
Interface Selections
Indicator
Languages
None
None
Advanced
Advanced
None
Yes (Zero/Span Only)
None
Yes
None
None
EN, DE, IT, FR, SP, RU, TU
EN, DE, IT, FR, SP, RU, TU
TABLE V
CONFIGURATION SELECTIONS
Diagnostics
a. Diagnostics
Selection
0
A
B
C
D
E
F
G
H
K
L
20
Standard Diagnostics
Selection
Interface Options
b. Interface
Measurement
c. Compensations
None
Write Protect
e. General
Configuration
3
High>
Low<
High>
Low<
Disabled
Disabled
Enabled
Enabled
Enabled
Disabled
d. Output Limit,
Failsafe & Write
Protect Settings
Fail Mode
21.0mAdc
3.6mAdc
21.0mAdc
3.6mAdc
Honeywell
Honeywell
Honeywell
Honeywell
N/A
N/A
Std
Std
Std
Std
Factory Standard
Custom Configuration (Unit Data Required from customer)
TABLE VI
Accuracy and
Calibration
TABLE VII
a. Customer
Tag
b. Unassembled
Conduit
Plugs &
Adapters
TABLE VIII
Calibrated Range
ACCESSORY SELECTIONS
No customer tag
One Wired Stainless Steel Tag (Up to 4 lines 26 char/line)
Two Wired Stainless Steel Tag (Up to 4 lines 26 char/line)
No Conduit Plugs or Adapters Required
1/2 NPT Male to 3/4 NPT Female 316 SS Certified Conduit Adapter
1/2 NPT 316 SS Certified Conduit Plug
M20 316 SS Certified Conduit Plug
Certifications &
Warranty
NACE MR0175; MR0103; ISO15156 Process wetted, pressure retaining parts only
EN10204 Type 3.1 Material Traceability; pressure retaining parts
Certificate of Conformance
Calibration Test Report & Certificate of Conformance
Certificate of Origin
FMEDA (SIL 2/3) Certification
WHG Overfill Protection
PMI Certification
Extended Warranty Additional 1 year
Extended Warranty Additional 2 years
Extended Warranty Additional 3 years
Extended Warranty Additional 4 years
TABLE IX
Factory
Calibration Qty
Manufacturing Specials
Application and Validation Tool (AVT) Configuration File Reference #
Factory Default Configuration, No AVT File
Selection
Selection
00
FG
FX
F3
F1
F5
FE
WG
PM
26
MODEL RESTRICTIONS
Restriction Letter
Selection(s)
If
II
If
f
g
_S__
If
If
II
_ S_ _
IVb
_F_
If
II
_S__
If
II
j
k
II
IVb
_F_
II
NS7A, GS7A
If
II
NC7A, GC7A
If
Vd
_ _ _1 _, _ _ _2 _, _ _ _6 _
II
II
_C__
IVb
_H_
If
If
m
n
II
IVa
IVa
_C__
B_ _, D_ _, F_ _, H_ _, K _ _, M _ _
A_ _, C_ _, E_ _, G_ _, J _ , L _ _
Ia
_S__
Select only one option from this group
II
d
Table
SWA_ _ _ _ _ _ _ _ _ _,
SWB_ _ _ _ _ _ _ _ _ _,
1a,1b
SWAW _ _ _ _ _ _ _ _ _,
SWBW _ _ _ _ _ _ _ _ _,
SRA_ _ _ _ _ _ _ _ _ _,
SRB_ _ _ _ _ _ _ _ _ _,
SRH_ _ _ _ _ _ _ _ _ _,
SRJ_ _ _ _ _ _ _ _ _ _,
SRM_ _ _ _ _ _ _ _ _ _,
SRN_ _ _ _ _ _ _ _ _ _,
SRK_ _ _ _ _ _ _ _ _ _,
SRL_ _ _ _ _ _ _ _ _ _,
SRC_ _ _ _ _ _ _ _ _ _
If
II
_ S_ _
Ia
SWA_ _ _ _ _ _ _ _ _ _,
SWB_ _ _ _ _ _ _ _ _ _
If
SWA_ _ _ _ _ _ _ _ _ _,
SWB_ _ _ _ _ _ _ _ _ _,
u
Ia
If
II
_ S_ _
1a
ARA_ _ _ _ _ _ _ _ _ _,
ARD_ _ _ _ _ _ _ _ _ _,
ARE_ _ _ _ _ _ _ _ _ _
27
ACCESSORIES
Description
Part Number
50127238-501
51000000-502
Kit Number
50096657-501
50096657-502
50095191-502
50095191-510
50095191-501
50095191-509
50096656-501
50096656-502
50096656-503
50096656-504
ASIA PACIFIC
EMEA
AMERICAS
Australia
Honeywell Limited
Phone: +(61) 7-3846 1255
FAX: +(61) 7-3840 6481
Toll Free 1300-36-39-36
Toll Free Fax:
1300-36-04-70
Email: (Sales)
[email protected]
or
(TAC)
[email protected]
Email: (Sales)
[email protected]
or
(TAC)
[email protected]
Process Solutions
Honeywell
1250 W Sam Houston Pkwy S
Houston, TX 77042
Honeywell Control Systems Ltd
Honeywell House, Skimped Hill Lane
Bracknell, England, RG12 1EB
Shanghai City Centre, 100 Jungi Road
Shanghai, China 20061
www.honeywellprocess.com
34-SL-03-03
August 2016
2016 Honeywell International Inc.