Volum Water Hydrotest

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

TRUNK LINE CTDP

Doc. Tide

VOLUME OF WATER REO.LURED TO FILL TEST SECTION 2

I. PURPOSE

The purpose of this calculation is to determine the volume required to fill test section.

II. PARAMETER DATA

DESCRIPTION

SYMBOL

BRITISH

UNIT

METRIC

Length of test section

8,078

Inside diameter of pipe

10.02 inch

254.508 mm

Out side diameter

10.750 inch

273.050 mm

Pipe wall thickness

0.365 inch

9.271 mm

Gallon required to fill @ 0 Psi

13.000 km

mile

L*(0.31416*d2/4)

174,715.86

gallon

661.372 m 3

Test Pressure

675 Psi

46.552 bar

Temperature

168 OF

75.55555556 C

Factor to correct for the compressibility of

Fwp

water due to increasing pressure from 0 psi

Fwp

UNIT

1/(1_((4.5d1 0f(_5))*(P/14.73)))
1.002066379

to test pressure, P, Psi


Factor to correct for volume change in

Fpp

pipeline due to pressure increase from 0

Fpp

1 +

((D/t)*(0.91*P/30d10A6))I(3.6*10fS(_6)*(T_40))
1.001063831

psi to test pressure P, Psi

1((T_40)*18.2*10A(_6))

due to thermal expansion of pipe from

Fpt

base temperature of 60 F

Fpt

1.0023296

Factor to correct for thermal change in

Fwt

0.999931

specific water volume from 40 F to test


water temparature. Refer to table 1
Factor to correct for the change in water
volume and pipe volume due to change in
pipe and water temperature from base of

Fpwt
Fpwt

Fpt/Fwt

______________
1.002398766

60' F to pipe and water test temperature T-

Gallon contained in test section at test


pressure P, and temperature T- F
Incremental volume required to reach test
pressure

Vtp
Vtp

Vtp
17,683.56

V*F% p*Fpp*Fp w t
Gallon

665.0346413 m 3

Vtp - V
967.6965944Gallon

3.663130301 m3

TRUNK LINE CTDP

Doc. Title

VOLUME OF WATER REQUIRED TO FILL TEST TOTAL SECTION

I. PURPOSE
The purpose of this calculation is to determine the volume required to fill test section.

II. PARAMETER DATA

DESCRIPTION

SYMBOL

BRITISH

METRIC

UNIT

25.000 km

Length of test section

15.534 mile

Inside diameter of pipe

10.02 inch

254.508 mm

Out side diameter

10.750 inch

273.050 mm

Pipe wall thickness

0.365 inch

9,271 mm

Gallon required to fill @ 0 Psi

V
V

L(0.31416'd''2/4)
335978.7273

1271.818 m 3

gallon

Test Pressure

675 Psi

46.552 bar

Temperature

168 OF

75.55555556 C

Factor to correct for the compressibility of

Fwp

water due to increasing pressure from 0 psi

Fwp

UNIT

1/(1_((4.5*1O(_5))*(P/14.73)))

1.0020663791

to test pressure, P, Psi


Factor to correct for volume change in

Fpp

pipeline due to pressure increase from 0

Fpp

((D/t)*(0.91 *p/3*j 0A6))+(3.6*1OA(_b)*(T_40))


1.001063831

psi to test p r essu re P, Psi

1+((T_40)*18.2*IOA(_6))

due to thermal expansion of pipe from

Fpt

base temperature of 60 F

Fpt

1.0023296

Factor to correct for thermal change in

Fwt

0.999931

specific water volume from 40 F to test


water temparature. Refer to table 1
Factor to correct for the change in water

FptJFt

Fpwt

volume and pipe volume due to change in


pipe and water temperature from base of

Fpwt

1.002398766

60 F to pipe and water test temperature T-

Gallon contained in test section at test

vtp

pressure P, and temperature T-F


Incremental volume required to reach test
pressure

vtp
__

Vtp = V*F w p*Fpp*Fp w t


337,839.51

Gallon

1278.862109 m 3

Vtp - V
1860.8Sl27IGallon

7.044202289 m3