ACW
Circuit
Protection
Molded-Case Circuit Breaker
UL 489 Listed
Disconnect
Switches
The WEG ACW Series of Molded Case Circuit Breakers are designed to
provide overload and short-circuit protection for industrial electrical
equipment. Available in four different compact frame sizes, the ACW is
a top performing, safe, reliable solution for applications from 15 to
800Amps. Common eld installable plug-in accessories simplify
selection and minimize inventory variations.
Motor
Protectors
General
Information
Circuit Protection
Standard Features
Contactors
High short-circuit interrupting ratings up to 65Ka@480V
Adjustable Thermal trip settings- 128-800A
Complete line of field installable accessories
Suitable for reverse feed applications
Compact frame
Rated
current In
Overloads
Enclosed
Starters
Relays
Pushbuttons
and Pilot
Lights
Fixed thermal and xed
magnetic (only ACW125)
Adjustable thermal and
xed magnetic
(only ACW250, 400 and
800)
Terminal
Blocks
15
20A
20
30A
30
40A
40
50A
50
60A
60
80
100A
100
125A
125
160A
160
200A
200
Code
250A
250
FTU
300A
300
400A
400
500A
500
600A
600
700A
700
800A
800
FMU
15A
80A
ACW Catalog Number Sequence
Trip unit
Power
Factor
Correction
Appendix Appendix
A
B
kA rating @
460VAC
Code
Code
35
125
ACW125
65
250
ACW250
400
ACW400
800
ACW800
Frame
Code
Number of
poles
3
Code
3
Chart intended as reference only and not to create part numbers.
6 | 1-800-ASK4WEG | www.weg.net/us
Data is subject to change without notice.
ACW
OFF
TRIP
AXa1
AXa1
AXc1
AXc1
AXb1
AXb1
Suitable for
Catalog Number
List Price
Multiplier
ACW125...800
AX ACW 125-800
$103
Z10
Alarm contact
ACW
ON
OFF
TRIP
Ala1
Alarm contact
Overloads
Alarm contact offers provisions for audio and visual indication of a tripped breaker
due to overload, short-circuit, shunt trip or under voltage release conditions. The
contact opens when the circuit breaker is reset.
Ala1
ALc1
ALc1
ALb1
ALb1
Catalog Number
List Price
Multiplier
ACW125...800
AL ACW 125-800
$103
Z10
Relays
Suitable for
Shunt release
ACW125...800
Data is subject to change without notice.
Rated voltage
Catalog Number
List Price
12VDC
SHT C02 ACW 125-800
$235
24VAC/DC
SHT E26 ACW 125-800
$235
48VAC/DC
SHT E27 ACW 125-800
$235
110-130VAC/DC
SHT E10 ACW 125-800
$235
220-240VAC/250VDC
SHT E14 ACW 125-800
$235
380-500VAC
SHT E52 ACW 125-800
$235
Multiplier
Z10
WEG Automation - Products and Solutions | 9
Power
Factor
Correction
Range of operational voltage: 0.71.1xUn
Frequency: 4565Hz
Terminal
Blocks
Pushbuttons
and Pilot
Lights
The shunt release opens the breaker in response to
an externally voltage signal.
Suitable for
Enclosed
Starters
Auxiliary contact
Disconnect
Switches
ON
Motor
Protectors
ACW
Contactors
The auxiliary contact block contains one set of form C
contacts. This contact indicates remote circuit-breaker
status ON and OFF.
Appendix Appendix
B
A
Auxiliary contact
Circuit
Protection
Internal accessories
General
Information
Circuit Protection
General
Information
Circuit Protection
ACW
Internal accessories
Circuit
Protection
Under voltage release
The under voltage release automatically opens a circuit breaker when
voltage drops to a value ranging between 35% to 70% of the line voltage.
The operation is instantaneous, and after tripping, the circuit breaker
cannot be reset until the voltage returns to 85% of line voltage.
Disconnect
Switches
Range of voltage trip: 0.350.7xUn
MCCB reset voltage: 0.85xUn (exceed)
Frequency: 4565Hz
Suitable for
Motor
Protectors
ACW125...800
Rated voltage
Catalog Number
List Price
24VAC/DC
UVT E26 ACW 125-800
$235
48VAC/DC
UVT E27 ACW 125-800
$235
UVT E10 ACW 125-800
$235
UVT E14 ACW 125-800
$235
380-440VAC
UVT E53 ACW 125-800
$235
440-480VAC
UVT E54 ACW 125-800
$235
Contactors
110-130VAC/DC
220-240VAC/250VDC
Multiplier
Z10
Conguration of internal accessories
Overloads
Phase (side)
R (left)
Enclosed
Starters
T (right)
Accessory
AX
AL
SHT or UVT
AX
AL
ACW125
0
1
1
2
0
ACW250
1
1
1
1
0
ACW400
3
0
1
0
1
ACW800
3
0
1
0
2
Possible conguration of internal accessories
Relays
ACW125
AL
Pushbuttons
and Pilot
Lights
AX AX
ACW250
AX
ACW400
ACW800
AX
AL
SHT/UVT
AX AX AX
AX AX AX
AL AL
AL
SHT/UVT
SHT/UVT
Terminal
Blocks
SHT/UVT
Power
Factor
Correction
Appendix Appendix
A
B
10 | 1-800-ASK4WEG | www.weg.net/us
Data is subject to change without notice.
ACW
No
Yes
operations
operations
Lbs/kg
in/mm
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
4,000
4,000
2.65/1.2
3.54x6.46x3.39/90x164x86
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
4,000
4,000
2.65/1.2
4.13x7.01x3.39/105x178x86
Overloads
Yes
No
VAC
kA
Enclosed
Starters
FTU
FMU
Relays
ACW250
250
150, 160, 175, 200, 225, 250
3
600
P
W
50
100
35
65
10
18
UL 489
Pushbuttons
and Pilot
Lights
ACW125
125
15, 20, 30, 40, 50, 60, 80, 100, 125
3
600
P
W
50
100
50
100
35
65
10
14
UL 489
Terminal
Blocks
Units
Appendix Appendix
B
A
Power
Factor
Correction
Models
Frame size
Rated current In @ 40C
No. of poles
Rated operational voltage - Ue
UL interrupting rating - Icu
120VAC
240VAC
480VAC
600VAC
Reference standard
Trip unit (Thermal-magnetic)
Fixed thermal, xed magnetic
Adjustable thermal, xed magnetic
Accessories
Auxiliary contact (AX)
Alarm contact (AL)
Shunt release (SHT)
Under voltage (UVT)
Rotary handle
Flange handle
Locking devices (pad and handle lock)
Mechanical interlock block
Wiring terminals
Mechanical life
Electrical life @ 600VAC
Weight
Dimensions (width x height x depth)
Contactors
Motor
Protectors
Disconnect
Switches
Circuit
Protection
Technical Data
General
Information
Circuit Protection
Data is subject to change without notice.
WEG Automation - Products and Solutions | 15
General
Information
Circuit Protection
ACW
Circuit
Protection
Disconnect
Switches
Motor
Protectors
Contactors
Overloads
Enclosed
Starters
Relays
Models
Frame size
Rated current In @ 40C
No. of poles
Rated operational voltage - Ue
UL interrupting rating - Icu
120VAC
240VAC
480VAC
600VAC
Reference standard
Trip unit (Thermal-magnetic)
Fixed thermal, xed magnetic
Adjustable thermal, xed magnetic
Accessories
Auxiliary contact (AX)
Alarm contact (AL)
Shunt release (SHT)
Under voltage (UVT)
Rotary handle
Flange handle
Locking devices (pad and handle lock)
Mechanical interlock block
Wiring terminals
Mechanical life
Electrical life @ 600VAC
Weight
Dimensions (width x height x depth)
Units
ACW400
400
300, 350, 400
3
600
UL 489
ACW800
800
500, 600, 700, 800
3
600
P
W
50
100
35
65
18
25
UL 489
FTU
FMU
No
Yes
No
Yes
operations
operations
Lbs/kg
in/mm
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Standard
5,000
1,000
12.57/5.7
5.51x11.50x4.33/140x292x110
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Standard
3,000
500
29.98/13.6
8.27x16.85x5.31/210x428x135
A
VAC
P
50
35
14
W
100
65
20
Auxiliary Contact (AX) & Alarm Contact (AL)
Pushbuttons
and Pilot
Lights
Conventional thermal current (Ith)
Rated operational current (Ie)
50/60Hz
[V]
120Vac
240Vac
480Vac
Terminal tigheting torque [lb.in (N/m)]
Shunt Release
Terminal
Blocks
[V]
Power consumption
Power
Factor
Correction
24Vac
48Vac
110-130Vac
220-240Vac
380-500Vac
Appendix Appendix
A
B
Maximum opening time [msec]
Terminal tigheting torque [lb.in (N/m)]
Undervoltage Release
Drop-out voltage [% of Vn]
Reset voltage [% of Vn]
Maximum opening time [msec]
Terminal tigheting torque [lb.in (N/m)]
16 | 1-800-ASK4WEG | www.weg.net/us
Inductive Load
3
2
1.5
Consumption
[VA]
0.58
1.22
1.36
1.8
1.15
50
7 (0.8)
[mA]
24
25
10.5
7.5
2.3
0.35 - 0.7 x Vn
0.85 x Vn
[V]
Power consumption
5A
Resistive Load
5
3
2
7 (0.8)
24Vac
48Vac
110-130Vac
220-240Vac
380-500Vac
Consumption
[VA]
0.64
1.09
0.73
1.21
1.68
50
7 (0.8)
[mA]
27
23
5.8
5.4
3.5
Data is subject to change without notice.
ACW
Models
ACW125
ACW250
Circuit
Protection
Screw mounting
ACW400
ACW800
4EA
(NO.10-24 UNC-2A, L120)
4EA
(1/4-20 UNC2A, L140)
N.A.
N.A.
N.A.
N.A.
4EA
(NO.8-32 UNC-2A, L100)
Motor
Protectors
Screw for mounting
6EA(M8L20)
Torque:
Max 197kgfcm
170lbfin
Contactors
Screw for connection of
terminals
6EA(M5L16)
Torque:
Max 78kgfcm
67.7lbfin
Overloads
Note: ACW400 and ACW800 are supplied with non-removable lugs.
Connecting terminal and conductor
Conductor (mm)
18
Enclosed
Starters
Terminal (mm)
Disconnect
Switches
Screw and connection
General
Information
Circuit Protection
23
Relays
ACW125
Pushbuttons
and Pilot
Lights
M5x16
22
Terminal
Blocks
20
Max 78kgfcm
28
>8
>8
21
M8x20
10
25
10
25
Appendix Appendix
B
A
22
Max 147kgfcm
Note: ACW400 and ACW800 are supplied with non-removable lugs.
Data is subject to change without notice.
Power
Factor
Correction
ACW250
WEG Automation - Products and Solutions | 17
General
Information
Circuit Protection
ACW
Dimensions - inch (mm)
Circuit
Protection
ACW125
Disconnect
Switches
Motor
Protectors
Contactors
Overloads
Drilling
template
Front view
cut-out
Enclosed
Starters
Relays
ACW250
Pushbuttons
and Pilot
Lights
Terminal
Blocks
Power
Factor
Correction
Appendix Appendix
A
B
Front view
cut-out
Drilling
template
32 | 1-800-ASK4WEG | www.weg.net/us
Data is subject to change without notice.
ACW
Circuit
Protection
Dimensions - inch (mm)
General
Information
Circuit Protection
Drilling
template
Overloads
Contactors
Motor
Protectors
Disconnect
Switches
ACW400
Enclosed
Starters
Front view
cut-out
Power
Factor
Correction
Terminal
Blocks
Pushbuttons
and Pilot
Lights
Relays
ACW800
Drilling
template
Data is subject to change without notice.
Appendix Appendix
B
A
Front view
cut-out
WEG Automation - Products and Solutions | 33
General
Information
Circuit Protection
ACW
Dimensions - inch (mm)
Circuit
Protection
Extended rotary handle - ACW125
14.5 (368.3)
Disconnect
Switches
14.5(368.3) - 12 shaft
18.5(470) - 16 shaft
26.5(673.1) - 24 shaft
Motor
Protectors
Contactors
Overloads
Enclosed
Starters
Relays
Pushbuttons
and Pilot
Lights
Panel drilling
Installation Diagram
Terminal
Blocks
Power
Factor
Correction
Appendix Appendix
A
B
34 | 1-800-ASK4WEG | www.weg.net/us
Data is subject to change without notice.
ACW
Circuit
Protection
Dimensions - inch (mm)
General
Information
Circuit Protection
Extended rotary handle - ACW250
14.54 (369.3)
Pushbuttons
and Pilot
Lights
Relays
Enclosed
Starters
Overloads
Contactors
Motor
Protectors
Disconnect
Switches
14.54 (369.3) -12 shaft
18.54 (471) - 16 shaft
26.54 (674.1) - 24 shaft
Installation Diagram
Appendix Appendix
B
A
Power
Factor
Correction
Terminal
Blocks
Panel drilling
Data is subject to change without notice.
WEG Automation - Products and Solutions | 35
General
Information
Circuit Protection
ACW
Dimensions - inch (mm)
Circuit
Protection
Extended rotary handle - ACW400
Disconnect
Switches
15.93 (404.6) -12 shaft
19.93 (506) - 16 shaft
27.93 (709.4) -24 shaft
Motor
Protectors
Contactors
Overloads
Enclosed
Starters
Relays
Pushbuttons
and Pilot
Lights
Terminal
Blocks
Panel drilling
Installation Diagram
Power
Factor
Correction
Appendix Appendix
A
B
36 | 1-800-ASK4WEG | www.weg.net/us
Data is subject to change without notice.
ACW
Circuit
Protection
Dimensions - inch (mm)
General
Information
Circuit Protection
Extended rotary handle - ACW800
Installation Diagram
Appendix Appendix
B
A
Power
Factor
Correction
Panel drilling
Terminal
Blocks
Pushbuttons
and Pilot
Lights
Relays
Enclosed
Starters
Overloads
Contactors
Motor
Protectors
Disconnect
Switches
17.42 (442.5) - 12 shaft
21.42 (541.2) - 16 shaft
29.42 (747.32) - 24 shaft
Data is subject to change without notice.
WEG Automation - Products and Solutions | 37
General
Information
Circuit Protection
ACW
Dimensions - inch (mm)
Circuit
Protection
Flange Handle ACW125
Disconnect
Switches
Motor
Protectors
Contactors
Overloads
Way of installation
Panel drilling
Set screw (5mm)
Enclosed
Starters
Relays
Pushbuttons
and Pilot
Lights
Terminal
Blocks
Table 1
Maximum "E" Dimension
Table 2
Maximum "F" Dimension
60 cable
72 cable
Power
Factor
Correction
Appendix Appendix
A
B
Enclosure
Depth
60 cable
72 cable
Enclosure
Depth
Up
Down
Up
Down
10
12
16
18
20
24
30
36
25
24
23
22
21
20
19
18
30
29
28
27
26
25
24
23
10
12
16
18
20
24
30
36
17
17
17
17
16
14
11
6
31
31
28
28
26
26
24
21
20
19
19
19
18
16
13
8
34
33
30
30
28
28
26
22
38 | 1-800-ASK4WEG | www.weg.net/us
Data is subject to change without notice.
ACW
Circuit
Protection
Dimensions - inch (mm)
General
Information
Circuit Protection
Overloads
Contactors
Motor
Protectors
Disconnect
Switches
Flange Handle ACW250
Enclosed
Starters
Installation Diagram
Panel drilling
Table 2
60 cable
72 cable
Enclosure
Depth
10
12
16
18
20
24
30
36
25
24
23
22
21
20
19
18
30
29
28
27
26
25
24
23
10
12
16
18
20
24
30
36
Data is subject to change without notice.
Up
17
17
17
17
16
14
11
6
Maximum "F" Dimension
60 cable
72 cable
Down
Up
Down
31
20
34
31
19
33
28
19
30
28
19
30
26
18
28
26
16
28
24
13
26
21
8
22
WEG Automation - Products and Solutions | 39
Power
Factor
Correction
Maximum "E" Dimension
Appendix Appendix
B
A
Table 1
Enclosure
Depth
Terminal
Blocks
Pushbuttons
and Pilot
Lights
Relays
Set screw (5mm)
General
Information
Circuit Protection
ACW
Dimensions - inch (mm)
Circuit
Protection
Flange Handle ACW400
Disconnect
Switches
Motor
Protectors
Contactors
Overloads
Installation Diagram
Panel drilling
Enclosed
Starters
Set screw (5mm)
Relays
Pushbuttons
and Pilot
Lights
Terminal
Blocks
Table 1
Maximum "E" Dimension
Table 2
Power
Factor
Correction
Appendix Appendix
A
B
Enclosure
Depth
60 cable
72 cable
Enclosure
Depth
10
12
16
18
20
24
30
36
25
24
23
22
21
20
19
18
30
29
28
27
26
25
24
23
10
12
16
18
20
24
30
36
40 | 1-800-ASK4WEG | www.weg.net/us
Up
17
17
17
17
16
14
11
6
Maximum "F" Dimension
60 cable
72 cable
Down
Up
Down
31
20
34
31
19
33
28
19
30
28
19
30
26
18
28
26
16
28
24
13
26
21
8
22
Data is subject to change without notice.
ACW
Circuit
Protection
Dimensions - inch (mm)
General
Information
Circuit Protection
Enclosed
Starters
Installation diagram
Panel drilling
Overloads
ACW SERIES
Contactors
Motor
Protectors
Disconnect
Switches
Flange Handle ACW800
Table 2
60 cable
72 cable
Enclosure
Depth
10
12
16
18
20
24
30
36
25
24
23
22
21
20
19
18
30
29
28
27
26
25
24
23
10
12
16
18
20
24
30
36
Data is subject to change without notice.
Maximum "F" Dimension
60 cable
72 cable
Up
Down
Up
Down
17
31
20
34
17
31
19
33
17
28
19
30
17
28
19
30
16
26
18
28
14
26
16
28
11
24
13
26
6
21
8
22
WEG Automation - Products and Solutions | 41
Power
Factor
Correction
Maximum "E" Dimension
Appendix Appendix
B
A
Table 1
Enclosure
Depth
Terminal
Blocks
Pushbuttons
and Pilot
Lights
Relays
Set screw (5mm)
General
Information
Circuit Protection
ACW
Dimensions - inch (mm)
Circuit
Protection
Mechanical interlocking device - MIT
Disconnect
Switches
Motor
Protectors
Contactors
Overloads
A (inch)
B (inch)
ACW125
3.267
3.385
ACW250
4.015
3.385
ACW400
6.614
4.330
ACW800
7.193
5.314
Enclosed
Starters
Mechanical interlocking device - Mounting dimension for MIT
Relays
Pushbuttons
and Pilot
Lights
Terminal
Blocks
Power
Factor
Correction
Appendix Appendix
A
B
42 | 1-800-ASK4WEG | www.weg.net/us
3 Pole
MCCB
C(inch)
D(inch)
E(inch)
ACW125
4.212
3.543
1.181
ACW250
4.921
4.133
1.377
ACW400
7.874
5.490
1.830
ACW800
10.944
8.267
2.755