Saudi Diyar Consultants: King Faisal Specialist Hospital AND Research Centre

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1

MATCH LINE SEE DWG NO. 1257B03-S105c

CLIENT

A
1

7
100800

8400

8400

8400

8400

8400

8400

KING FAISAL
SPECIALIST HOSPITAL
AND
RESEARCH CENTRE

CONSULTANT:
8400

Saudi Diyar Consultants

A.2

9000

SUB CONSULTANT:

NOTES:

A.1
19300

1.

FOR GENERAL NOTES, SEE DWG. NO. 1257B01-S001...

2.

ALL DIMENSIONS & LEVELS ARE TO BE COORDINATED


WITH ARCHITECTURAL & CIVIL DRAWINGS.

3.

ALL DIMENSIONS ARE IN MILLIMETERS.

4.

IN CASE OF ANY DISCREPANCY BETWEEN STRUCTURAL


DRAWINGS & SITE CONDITIONS, REFER TO THE
CONSULTING ENGINEER.

5.

ALL PIPE SLEEVES & OTHER BUILDER'S WORK


REQUIREMENTS FOR ELECTRO-MECHANICAL WORKS,
SHALL BE COORDINATED WITH THE APPROVED
ELECTRO-MECHANICAL SHOP DRAWINGS BEFORE
CONCRETING.

6.

ALL PERIMETER COLUMNS SHALL CONTINUE UP TO


PARAPET LEVEL, UNLESS OTHERWISE INDICATED.

7.

FOR SIZES & LOCATIONS OF SLAB OPENINGS,


TRENCHES & PITS REFER TO ELECTRO-MECH.
DRAWINGS.

8.

REINFORCING STEEL BARS SHALL BE DEFORMED HIGH


GRADE STEEL OF YIELD STRENGTH 4200 KG/SQ.CM.
(MIN.)

9.

UNLESS OTHERWISE SPECIFIED. REINFORCED


CONCRETE SHALL HAVE A MIN. 28 DAYS CYLINDER .
STRENGTH OF 400 KG/SQ.CM.

10300

400

CB10

2650

CB11

CB10

2650

B10

7b
B10

CB3

50 MM E.J.

400

10b

B10

COREDN
No. 07
& STAIR No. 06

L=3000

DN

CORE No. 10
& STAIR No. 07

650

L=4000

1200

UP

L=2000

L=4000

TOP OF BEAM
EL. + 4.90 M.

TOP OF BEAM
EL. + 5.00 M.

L=3000

2400

L=6000

3000

L=3000

2000

L=3000

2500

B1

2500

12000

L=6000

B10

L=6000

4000

B10

L=6000

1600

L=3000

B10
B10

L=

4400

TOP OF SLAB
EL. + 4.90 M.

1500

2300

1500

400

B10

B10

B10

5400

1500

B10

1500

4400

8400

B10

400

B26

4000
3000

2000

L=6000

B1

B9

B10

B10

B10

8400

B10

B10

2500

REVISED AS CLOUDED

05/17/2015

REVISED AS CLOUDED

02/03/2015

REVISED AS CLOUDED

07/23/2014

REV.NO.

4000

12

4000

TOP OF SLAB
EL. + 4.90 M.
B9

B10

B10

B10

DATE

KEY PLAN

3000

B1

DESCRIPTION

3000

L=6000

L=4000

4400

3000

8400

L=6000

4000

L=6000

B10

L=6000

4000

4000

B10

3000

L=6000

L=3000

D
B1

2500

4000

4000

3000

3000

AM

YS

SB10

CB10

4000
3000

3b

1257B03-S105b

FA

MECHANICAL
MA

ICT
ZM

CIVIL/LS

DRAWN BY

CHECKED BY

AE/HF

H.M

A.R

3000

L=6000

4000

L=6000

KING FAISAL
SPECIALIST HOSPITAL
AND
RESEARCH CENTRE
Jeddah - Saudi Arabia

4000
3000

B03 KITCHEN & LAUNDRY


DRAWING TITLE:

METERS

IC
EM

SCALE 1:100

AT

10

SC

STRUCTURAL

PROJECT TITLE:

1257B03-S105b

LEVEL-02 FRAMING PLAN - PART a


1a PARTIAL
SCALE
1:100 M.
1

3000

L=6000

L=6000

4000

4000

L=6000

L=3000

MATCH LINE SEE DWG NO. 1257B03-S105c

B9

B10

B10

8400

2500

SL

ELECTRICAL

TOP OF BEAM
EL. + 5.00 M.

B10

ARCHITECT

3000

4000

L=6000

PROJECT MANAGER

L=6000

3000

L=6000

L=6000

4000

4000

B10

L=6000

L=3000

SCALE

DATE

CAD FILE

1:100

JUNE 2014

1257B03-S105

DRAWING NUMBER

1257B03-S105a

REVISION

3
Saudi Diyar Consultants

You might also like