Contents
Description
Page
Introduction
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . .
SPD Series for Integration into Electrical
Distribution Equipment . . . . . . . . . . . . . . . . . . . . .
SPD Series for Mounting External to
Electrical Distribution Equipment . . . . . . . . . . . . .
SPD MAX Series Surge Protection . . . . . . . . . . . . .
SPC Surge Protective Device . . . . . . . . . . . . . . . . .
CVX050/100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SP1 Surge Protective Device. . . . . . . . . . . . . . . . . .
SP2 Surge Protective Device. . . . . . . . . . . . . . . . . .
AEGIS Powerline Filters. . . . . . . . . . . . . . . . . . . . . .
Sag Ride-Through (SRT2). . . . . . . . . . . . . . . . . . . . .
Electronic Voltage Regulator (EVR) . . . . . . . . . . . . .
Power-Sure 800 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power-Suppress 100 . . . . . . . . . . . . . . . . . . . . . . . .
2
2
2
2
2
2
2
V3-T2-5
V3-T2-7
V3-T2-11
V3-T2-16
V3-T2-20
V3-T2-24
V3-T2-27
V3-T2-29
V3-T2-31
V3-T2-36
V3-T2-40
V3-T2-42
V3-T2-46
2
2
Introduction
2
2
2
2
2
2
Current ratings up to 60 A
120 and 240 Vac units
24 and 48 Vdc units
DIN mounting available on
some models
Up to 80 kA of peak surge
protection
AC units are UL 1449 4th
Edition and UL 1283 5th
Edition listed
2
2
2
2
2
2
2
SPC Series
AEGIS Products
2
V3-T2-2
2.1
Ratings:
2
2
2
2
2
Surge Protective Devices can be
Integrated within a variety of Eaton
Electrical Assemblies
2
2
2
Copper bus
12, 18, 24, 30, 36 and
42 circuits
Bolt-on branch breakers
A full range of factory
installed modifications
and accessories
Fully rated or series rated
2
2
2
2
2
2
Power Conditioning
Sag Ride-Through (SRT2)
The sag ride-through (SRT2)
is a power conditioner that
corrects voltage sags to
maintain uptime and
productivity.
Electronic Voltage
Regulator (EVR)
The electronic voltage
regulator (EVR) is designed
to meet the needs of
customers who experience
voltage regulation problems
due to brownout conditions
from their electric utilities.
2
2
2
2
2
2
Electronic Voltage Regulator (EVR)
2
2
2
2
2
2
2
2
V3-T2-3
2.1
2
2
2
2
2
Application Description
Design build
Chain stores
Small facilities
SPC units
Light Commercial
CVX units
SP1 units
Large Projects
Commercial
Government
Schools
Institution
Military
Including:
Industrial
Including:
MCCs with SPD Series units installed protect drives from damage
OEM
Integrators
Medical equipment
CVX units
SPC units
2
2
2
2
2
SP1 units
SP2 units
AEGIS units for critical load applications
Telecommunications
Including:
Panelboards and automatic transfer switches with integrated SPD Series units
Cellular sites
Microwave
CVX units
SPC units
PCS
SP1 units
Paging systems
SP2 units
2
2
2
2
2
2
2
2
V3-T2-4
2.1
Contents
Description
Page
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Overview
SPD Series for Integration into Electrical
Distribution Equipment . . . . . . . . . . . . . . . . . . . . .
SPD Series for Mounting External to
Electrical Distribution Equipment . . . . . . . . . . . . .
SPD MAX Series Surge Protection . . . . . . . . . . . . .
SPC Surge Protective Device. . . . . . . . . . . . . . . . . .
CVX050/100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SP1 Surge Protective Device . . . . . . . . . . . . . . . . . .
SP2 Surge Protective Device . . . . . . . . . . . . . . . . . .
AEGIS Powerline Filters . . . . . . . . . . . . . . . . . . . . . .
Sag Ride-Through (SRT2) . . . . . . . . . . . . . . . . . . . . .
Electronic Voltage Regulator (EVR) . . . . . . . . . . . . .
Power-Sure 800 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power-Suppress 100 . . . . . . . . . . . . . . . . . . . . . . . .
V3-T2-2
V3-T2-7
V3-T2-11
V3-T2-16
V3-T2-20
V3-T2-24
V3-T2-27
V3-T2-29
V3-T2-31
V3-T2-36
V3-T2-40
V3-T2-42
V3-T2-46
Learn
Online
2
2
2
2
2
2
2
2
Product Description
Product Overview
Eatons SPD series surge
protective devices are the
latest and most advanced
UL 1449 4th Edition certified
surge protectors. Units are
available integrated within
Eaton electrical assemblies,
including panelboards,
switchboards, motor
control centers, switchgear,
automatic transfer switches
and bus plugs.
Safety Features
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-5
2.1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Basic
Standard
Standard with
Surge Counter
Integrated versions of
the unit are UL 1449
4th Edition recognized
components for the
United States and Canada,
covered by Underwriters
Laboratories certification
and follow-up service
Sidemount versions are
UL 1449 4th Edition listed
devices and are also
CSA approved
2
2
2
2
2
2
2
2
V3-T2-6
Technical Data
and Specifications
20 kA nominal discharge
current (In) rating
(maximum rating
assigned by UL)
50 through 400 kA surge
current capacity ratings
200 kA short-circuit current
rating (SCCR)
2.1
Contents
Description
Page
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . .
SPD Series for Integration into Electrical
Distribution Equipment
Standards and Certifications . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . .
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SPD Series for Mounting External to
Electrical Distribution Equipment . . . . . . . . . . . . .
SPD MAX Series Surge Protection . . . . . . . . . . . . .
SPC Surge Protective Device. . . . . . . . . . . . . . . . . .
CVX050/100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SP1 Surge Protective Device . . . . . . . . . . . . . . . . . .
SP2 Surge Protective Device . . . . . . . . . . . . . . . . . .
AEGIS Powerline Filters . . . . . . . . . . . . . . . . . . . . . .
Sag Ride-Through (SRT2) . . . . . . . . . . . . . . . . . . . . .
Electronic Voltage Regulator (EVR) . . . . . . . . . . . . .
V3-T2-2
V3-T2-5
V3-T2-8
V3-T2-8
V3-T2-9
V3-T2-10
V3-T2-11
V3-T2-16
V3-T2-20
V3-T2-24
V3-T2-27
V3-T2-29
V3-T2-31
V3-T2-36
V3-T2-40
2
2
2
2
2
2
2
2
2
2
Product Description
Application Description
Panelboards
Switchboards
Motor control centers
Switchgear
Automatic transfer
switches
Bus plugs
Features, Benefits
and Functions
2
2
2
2
2
2
In this installation, the SPD Series
is mounted directly to the panelboards
bus bars. This type of installation
will provide the best possible surge
protection by minimizing the
connected lead length.
2
2
2
2
2
2
2
2
2
The SPD Series is also available as an
integrated unit interfaced via a circuit
breaker resident in the electrical
assembly. This installation keeps
connected lead lengths short while
providing a means of disconnecting
power to the unit quickly and easily.
V3-T2-7
2
2
2
2.1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
kA Rating
050 = 50 kA per phase
080 = 80 kA per phase
100 = 100 kA per phase
120 = 120 kA per phase
160 = 160 kA per phase
200 = 200 kA per phase
250 = 250 kA per phase
300 = 300 kA per phase
400 = 400 kA per phase
ApplicationIntegrated Units 2
Series
SPD = Surge protective device
Voltage Code
240S = 120/240 single split-phase
208Y = 120/208 wye (4W+G)
220Y = 127/220 wye (4W+G)
400Y = 230/400 wye (4W+G)
480Y = 277/480 wye (4W+G)
600Y = 347/600 wye (4W+G)
240D = 240 delta (3W+G)
480D = 480 delta (3W+G)
600D = 600 delta (4W+G)
240H = 240 high-leg delta (4W+G) on B phase 1
Feature Package
1 = Basic
2 = Standard
3 = Standard + surge counter
Notes
1 Please consult the factory for 240 high-leg delta (4W+G) applications with high leg on C phase.
2 Units used in PRL1a, 2a, 3a and 3E panelboard applications are available in 50200 kA ratings only. Use the C option for
PRL1a, 2a, 3a and 3E panelboard applications when unit is connected through a circuit breaker.
Example: SPD250480D2J = SPD Series, 250 kA per phase, 480D voltage, standard feature package, motor control center application.
2
2
2
2
2
2
2
2
2
2
2
V3-T2-8
2.1
2
2
Specification
50, 80, 100, 120, 160, 200, 250, 300, 400 kA per phase
2
2
200 kA
SPD type
2
2
120/240
50/60 Hz
0.5 W
1.1 W
1.3 W
0.6 W
1.7 W
2.1 W
Protection modes
Single split-phase
Three-phase wye
Three-phase delta
L-G, L-L
2
2
2
600Y MCOV
240D MCOV
480D MCOV
600D MCOV
Ports
Operating temperature
Operating humidity
Operating altitude
Up to 16,000 ft (5000 m)
2
2
2
2
2
2
Meets or exceeds the requirements specified in IBC 2006, CBC 2007 and UBC Zone 4
2
2
2
2
2
2
2
V3-T2-9
2.1
2.02
(51.2)
0.95
(24.1)
2
2
3.42
(86.9)
NEUTRAL
2.52
(64.0)
SPD Series
Surge Protective Device
SURGE
GROUND
SURGE GROUND
Terminals
8.74
(222.0)
3.45
(87.6)
4x Mounting
2.52
(64.0)
SURGE GROUND
4.85
(123.2)
5.78
(146.8)
2
2
SURGE
GROUND
5.40
(137.2)
CAUTION
4.66
(118.4)
TORQUE
1.71
(43.4)
NEU/GND
36 IN. LBS.
SPD Series
Surge Protective Device
TORQUE
Mounting
3.42
(86.9)
FORM C CONTACTS
3.42
(86.9)
4x #1032 x 0.38 DP
Brass Terminals
9.50
(241.3)
NEU/GND
36 IN. LBS.
NEUTRAL
NEUTRAL
NEUTRAL
0.22
4x Mounting
(5.6)
3.42
(86.9)
0.26
(6.6)
NEUTRAL
4.66
(118.4)
NEU/GND
36 IN. LBS.
SURGE
GROUND
5.40
(137.2)
TORQUE
2
2
NEUTRAL
CAUTION
Mounting
3.42
(86.9)
2
2
2.02
(51.2)
FORM C CONTACTS
Bus 0.34
(8.6)
0.04
(1.0)
SURGE
GROUND
4.40
(111.8)
0.19
4x Mounting
(4.8)
NEUTRAL
SURGE
GROUND
Dimensions
SURGE GROUND
NEUTRAL
Terminals
8.74
(222.0)
9.50
(241.3)
Weights
50200 kA units
approximately 3.5 lb
(1.6 kg)
250400 kA units
approximately 7.0 lb
(3.2 kg)
2
2
V3-T2-10
0.22
4x Mounting
(5.6)
4x #1032 x 0.38 DP
Brass Terminals
2.1
Contents
Description
Page
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . .
SPD Series for Integration into Electrical
Distribution Equipment . . . . . . . . . . . . . . . . . . . . .
SPD Series for Mounting External to
Electrical Distribution Equipment
Catalog Number Selection . . . . . . . . . . . . . . . . .
Technical Data and Specifications. . . . . . . . . . . .
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SPD MAX Series Surge Protection . . . . . . . . . . . . .
SPC Surge Protective Device. . . . . . . . . . . . . . . . . .
CVX050/100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SP1 Surge Protective Device . . . . . . . . . . . . . . . . . .
SP2 Surge Protective Device . . . . . . . . . . . . . . . . . .
AEGIS Powerline Filters . . . . . . . . . . . . . . . . . . . . . .
Sag Ride-Through (SRT2) . . . . . . . . . . . . . . . . . . . . .
Electronic Voltage Regulator (EVR) . . . . . . . . . . . . .
Power-Sure 800 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power-Suppress 100 . . . . . . . . . . . . . . . . . . . . . . . .
V3-T2-2
V3-T2-5
V3-T2-7
2
2
2
2
V3-T2-12
V3-T2-13
V3-T2-14
V3-T2-16
V3-T2-20
V3-T2-24
V3-T2-27
V3-T2-29
V3-T2-31
V3-T2-36
V3-T2-40
V3-T2-42
V3-T2-46
2
2
2
2
2
2
2
2
2
Product Description
Features, Benefits
and Functions
2
2
2
2
All SPD Series sidemount units come
prewired and include a factoryinstalled conduit interface,
making installation very easy.
2
2
2
2
2
2
2
2
2
2
2
V3-T2-11
2.1
2
2
kA Rating
050 = 50 kA per phase
080 = 80 kA per phase
100 = 100 kA per phase
120 = 120 kA per phase
160 = 160 kA per phase
200 = 200 kA per phase
250 = 250 kA per phase
300 = 300 kA per phase
400 = 400 kA per phase
2
2
2
2
2
ApplicationSidemount Units
Series
SPD = Surge protective device
Voltage Code
240S = 120/240 single split-phase
208Y = 120/208 wye (4W+G)
220Y = 127/220 wye (4W+G)
400Y = 230/400 wye (4W+G)
480Y = 277/480 wye (4W+G)
600Y = 347/600 wye (4W+G)
240D = 240 delta (3W+G)
480D = 480 delta (3W+G)
600D = 600 delta (4W+G)
240H = 240 high-leg delta (4W+G) on B phase 1
Notes
1 Please consult the factory for 240 high-leg delta (4W+G) applications with high leg on C phase.
2 NEMA 1 flushmount units are available in 50200 kA ratings only.
Example: SPD250480D2K = SPD Series, 250 kA per phase, 480D voltage, standard feature package, housed in NEMA 1 enclosure.
K
L
M
N
O
P
Q
=
=
=
=
=
=
=
NEMA 1 enclosure
NEMA 1 flushmount enclosure 2
NEMA 1 enclosure with internal disconnect
NEMA 4 enclosure
NEMA 4 enclosure with internal disconnect
NEMA 4X enclosure (stainless steel)
NEMA 4X enclosure with internal disconnect
(stainless steel)
Feature Package
1 = Basic
2 = Standard
3 = Standard + surge counter
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-12
2.1
Specification
50, 80, 100, 120, 160, 200, 250, 300, 400 kA per phase
200 kA
SPD type
120/240
50/60 Hz
2
2
0.5 W
1.1 W
1.3 W
0.6 W
1.7 W
2.1 W
Protection modes
Single split-phase
Three-phase wye
Three-phase delta
L-G, L-L
2
2
2
600Y MCOV
240D MCOV
480D MCOV
600D MCOV
Ports
Operating temperature
40 F to 122 F (40 C to 50 C)
Operating humidity
Operating altitude
Up to 16,000 ft (5000 m)
Meets or exceeds the requirements specified in IBC 2006, CBC 2007 and UBC Zone 4
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-13
2.1
2
2
2
Dimensions
Approximate Dimensions in Inches (mm)
50200 kA Units in a NEMA 1 Rated Flushmount Enclosure,
Weight = 6.8 Lb
1.00
(25.4)
7.28
(184.9)
5.27
(133.9)
Flushmount Panel
(4) #832 Flat Hd Screws
2
2
2
10.48
(266.2)
10.48
(266.2)
12.05
(306.1)
5.24
(133.1)
2
2
0.78
(19.8)
2
2
2.00
(50.8)
3.48
(88.4)
4.41
(112.0)
0.40
(10.2)
14.00
(355.6)
0.20
(5.1)
7.47
(189.7)
12.05
(306.1)
11.25
(285.8)
0.68
(17.3)
5.24
(133.1)
0.20
(5.1)
8.00
(203.2)
11.25
(285.8)
0.68
(17.3)
1.00
(25.4)
0.78
(19.8)
2.00
(50.8)
3.48
(88.4)
4.41
(112.0)
5.00
(127.0)
7.47
(189.7)
11.00
(279.4)
0.11
(2.8)
1.76
(44.7)
0.40
(10.2)
0.98
(24.9)
9.14
(232.2)
6.69
(169.9)
2
2
2
2
2
2
12.05
(306.1)
10.48
(266.2)
2.00
(50.8)
5.76
(146.3)
6.69
(169.9)
0.20
(5.1)
0.66
(16.8)
12.30
(312.4)
7.47
(189.7)
0.40
(10.2)
0.78
(19.8)
2.75
(69.9)
0.20
(5.1)
5.76
(146.3)
6.55
(166.4)
2
2
2
2
2
2
2
2
V3-T2-14
11.50
(292.1)
10.73
(272.5)
2.61
(66.3)
0.67
(17.0)
5.24
(133.1)
0.78
(19.8)
11.25
(285.8)
11.14
(283.0)
2.1
SPD Series
Surge Protective Device
12.50
(317.5)
10.98
(278.9)
11.28
(286.5)
0.76
(19.3)
0.65
(16.5)
2.60
(66.0)
6.00
(152.4)
8.65
(219.7)
5.39
(136.9)
0.33
(8.4)
3.36
(85.3)
10.18
(258.6)
7.68
(195.1)
12.47
(316.7)
0.33
(8.4)
2
2
SPD Series
Surge Protective Device
11.75
(298.5)
0.76
(19.3)
0.65
(16.5)
4.10
(104.1)
7.68
(195.1)
SPD Series
Surge Protective Device
5.49
(139.4)
2
2
11.28
(286.5)
12.50
(317.5)
2
2
10.98
(278.9)
2
2
0.65
(16.5)
0.76
(19.3)
2
2
12.28
(311.9)
SPD Series
Surge Protective Device
5.49
(139.4)
12.75
(323.9)
11.98
(304.3)
3.12
(79.2)
11.75
(298.5)
SPD Series
Surge Protective Device
SPD Series
Surge Protective Device
6.00
(152.4)
8.65
(219.7)
2
2
0.33
(8.4)
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-15
2.1
2
Contents
SPD MAX
Description
Page
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . .
SPD Series for Integration into Electrical
Distribution Equipment . . . . . . . . . . . . . . . . . . . . .
SPD Series for Mounting External to
Electrical Distribution Equipment . . . . . . . . . . . . . .
SPD MAX Series Surge Protection . . . . . . . . . . . . . .
Catalog Number Selection. . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SPC Surge Protective Device
CVX050/100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SP1 Surge Protective Device . . . . . . . . . . . . . . . . . .
SP2 Surge Protective Device . . . . . . . . . . . . . . . . . .
AEGIS Powerline Filters . . . . . . . . . . . . . . . . . . . . . .
Sag Ride-Through (SRT2) . . . . . . . . . . . . . . . . . . . . .
Electronic Voltage Regulator (EVR) . . . . . . . . . . . . . .
Power-Sure 800. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power-Suppress 100 . . . . . . . . . . . . . . . . . . . . . . . . .
2
2
2
2
2
2
2
2
V3-T2-2
V3-T2-5
V3-T2-7
V3-T2-11
V3-T2-16
V3-T2-17
V3-T2-18
V3-T2-19
V3-T2-24
V3-T2-27
V3-T2-29
V3-T2-31
V3-T2-36
V3-T2-40
V3-T2-42
V3-T2-46
2
2
2
2
Product Description
Application Description
Features
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-16
IEEE C62.41.1
IEEE C62.41.2
IEEE C62.43-2005
IEEE C62.45-2002
IEEE C62.48-2005
IEEE C62.62-2010
2.1
2
SPM 250 480D 3 R
SPM
Application Suffix
Series
kA Rating
100 = 100 kA per phase
120 = 120 kA per phase
160 = 160 kA per phase
200 = 200 kA per phase
250 = 250 kA per phase
300 = 300 kA per phase
320 = 320 kA per phase
400 = 400 kA per phase
600 = 600 kA per phase
800 = 800 kA per phase
S =
T =
U =
V =
W=
X =
Y =
2
2
2
2
2
2
2
2
2
2
2
2
Notes
1 Please consult the factory for 240 high-leg delta (4W+G) applications with high leg on C phase.
SPD250480D3R = SPD MAX Series, 250 kA per phase, 480D voltage, standard with counter features package,
NEMA 4 enclosure with internal circuit breaker.
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-17
2.1
2
2
2
2
2
2
Specification
100 kA, 120 kA, 160 kA, 200 kA, 250 kA, 300 kA, 320 kA, 400 kA, 600 kA, 800 kA ratings available
20 kA
200 kA
SPD type
Enclosure types
Circuit breaker30 A
120/240
Single-phase
230
120/240 high leg phase wire will be identified with a tag from the factory
50/60 Hz
0.6 W
1.7 W
2.1 W
Protection modes
Single split-phase LN, LG, NG, LL, single-phase LN, LG, NG, three-phase delta LG, LL,
three-phase wye LN, LG, NG, LL, three-phase high leg delta LN, LG, NG, LL
230 V single-phase
150 V LN, 150 V LG, 150 V NG, 300 V LL, 320 V HN, 320 V HG, 470 V HL
240 V delta
480 V delta
600 V delta
Ports
1 or 2
Storage temperature
Operating altitude
Up to 16,000 ft (5000 m)
Weight
Not to exceed 52 lb
Rated 300 V, 16 A, 3012 AWG solid or stranded wire. Torque range 57 lb-in
2
2
2
2
2
15 years from the date of delivery to the purchaser, 20 years if the product is properly registered at www.eaton.com
RoHS compliant
Yes
V3-T2-18
2.1
Dimensions
Optional Entry
2 NPT Maximum
1 AWG Maximum
2.33
(59.2)
1.63
(41.4)
6.58
(167.1)
1.13
(28.7)
2
2
2
NPT Maximum
Form C Entry
12.00
(304.8)
Mounting Dimension
2
2
16.00
(406.4)
2 NPT Maximum
Optimal Entry
1 Maximum
2
2
16.75
(425.5)
Mounting
Dimension
17.50
(444.5)
17.50
(444.5)
2
2
8.00
(203.2)
2
2
Scale 1000
14.91
(378.7)
2.33
(59.2)
(4X) 0.31
(7.87)
1/420 Mounting
Hardware
2
2
NPT Maximum
Form C Entry
8.32
(211.3)
1.13
(28.7)
9.30
(236.2)
2
2
6.58
(167.1)
2.33
(59.2)
0.50
(12.7)
2
1.63
(41.4)
2 NPT Maximum
Optimal Entry
1 Maximum
13.00
(330.2)
14.00
(355.6)
2
2
2
V3-T2-19
2.1
2
Contents
SPC
Description
Page
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . .
SPD Series for Integration into Electrical
Distribution Equipment . . . . . . . . . . . . . . . . . . . . .
SPD Series for Mounting External to
Electrical Distribution Equipment . . . . . . . . . . . . . .
SPD MAX Series Surge Protection . . . . . . . . . . . . . .
SPC Surge Protective Device
Catalog Number Selection. . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CVX050/100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SP1 Surge Protective Device . . . . . . . . . . . . . . . . . .
SP2 Surge Protective Device . . . . . . . . . . . . . . . . . .
AEGIS Powerline Filters . . . . . . . . . . . . . . . . . . . . . .
Sag Ride-Through (SRT2) . . . . . . . . . . . . . . . . . . . . .
Electronic Voltage Regulator (EVR) . . . . . . . . . . . . . .
Power-Sure 800. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power-Suppress 100 . . . . . . . . . . . . . . . . . . . . . . . . .
2
2
2
2
2
2
2
2
V3-T2-2
V3-T2-5
V3-T2-7
V3-T2-11
V3-T2-16
V3-T2-21
V3-T2-22
V3-T2-23
V3-T2-24
V3-T2-27
V3-T2-29
V3-T2-31
V3-T2-36
V3-T2-40
V3-T2-42
V3-T2-46
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Application Description
Surge eventsshort-term
transients in voltage
threatening critical
downstream equipment
happen for many reasons.
The most common source,
though, is internal devices
powering on and off: motors,
transformers, photocopiers,
fluorescent lighting ballasts,
light dimmers, fax machines
and more. They can also be
generated externally by
events like lightning, grid
switching or electrical
equipment in adjacent
buildings.
V3-T2-20
Features
The best way to prevent
downtime from an electrical
surge is through facility-wide
cascaded surge protection at
all stages of the electrical
distribution system. When
properly installed, surge
protective devices can
mitigate problems with
susceptible equipment,
keeping it and its related
processes running reliably
without surge-related
disruptions.
Eatons SPC Series surge
protective device (SPD) is a
key component to your
cascaded protection strategy.
Its compact, flexible and
configurable to protect most
electrical applications,
including service entrances,
distribution panelboards and
point-of-use applications.
2.1
2
2
2
2
SPC
2
SPC 200 208Y 8 P
Series
SPC
kA Rating (Options)
050 = 50 kA per phase
080 = 80 kA per phase
100 = 100 kA per phase
120 = 120 kA per phase
150 = 150 kA per phase
160 = 160 kA per phase
200 = 200 kA per phase
Enclosure
P = NEMA 4X
120N
240N
277N
480N
240S
240D
480D
600D
240H
208Y
415Y
480Y
600Y
=
=
=
=
=
=
=
=
=
=
=
=
=
2
2
Features
1=
2=
3=
4=
5=
6=
7=
8=
Options
No options (standard configuration)
Filtering, UL 1283 5th Edition
Audible alarm
Form C relay
Audible alarm and Form C relay
Filtering and audible alarm
Filtering and Form C relay
Filtering, audible alarm and Form C relay
SPD
Application
Type 1
Type 2
Type 1
Type 1
Type 1
Type 2
Type 2
Type 2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-21
2.1
SPC
Description
Specification
20 kA
200 kA
120/240
240
50/60 Hz
Protection modes
2
2
240N, 277N
480N
240S, 208Y
240H
150 L-N, 150 L-G, 150 N-G, 300 L-L, 470 H-L, 320 H-N, 320 H-G
600Y
240D
480D
600D
Ports
Operating temperature
40 F to 140 F (40 C to 60 C)
Storage temperature
40 F to 140 F (40 C to 60 C)
Operating humidity
Operating altitude
Agency certification/listing
UL 1449 4th edition, UL 1283 6th edition, CSA C22.2 No. 269.1-14 for Type 1 SPD,
CSA C22.2 No. 269.2-13 for Type 2 SPD, CSA C22.2 no. 8-13 for EMI Filter
Passed 15,000 strikes to ANSI/IEEE C62.41 (20 kV, 10 kA) Category C Waveform
SPD type
UL 1449 4th edition and CSA Type 1 and Type 2 SPD (dependent on feature options)
Enclosure rating
NEMA 4X enclosure 1
2
2
2
2
RoHS compliant
Yes
Warranty
P2 Enclosure
120N/240N/277N/480N = 50200 kA
240S = 120200 kA
240S = 50100 kA
208Y/415Y/480Y/600Y = 120200 kA
208Y/415Y/480Y/600Y = 50100 kA
240D/480D = 120200 kA
240D/480D = 5000 kA
600D = 50200 kA
240H = 50100 kA
240H = 120200 kA
2
2
Note
1 Mounting feet required to achieve NEMA 4X rating.
V3-T2-22
2.1
Dimensions
Approximate Dimensions in Inches (mm)
P1
2
2
3.75
(95.3)
36-inch
long wires
Mounting feet
(included)
0.75 (19.1)
Locknut
3/4-14 NPS
external thread
1.00 (25.4)
6.00
(152.3)
Lid
1.12 (28.5)
ID508
5.50 (139.6)
Lid
6.62 (168.1)
4x #8 [m 4]
Flathead screw
(not included)
Overall base
including
stabilization ribs
5.56 (141.2)
2
2
2
3.19
(81.0)
2
2
7.13 (181.2)
0.16 (4.1)
Mounting feet
(included)
2
2
P2
2
3.75
(95.3)
8.50
(215.9)
Lid
2
2
36-inch
long wires
Mounting feet
(included)
7.50 (190.5) Lid
8.62 (219.0)
0.75 (19.1)
Locknut
3/4-14 NPS
external thread
1.00 (25.4)
2.38
(60.4)
4x #8 (m4)
Flathead screw
(not included)
7.56 (192.0)
overall base including
stabilization ribs
2
2
3.19
(81.1)
2
2
9.13 (232.0)
0.16 (4.1)
mounting feet
(included)
2
2
2
2
2
2
2
V3-T2-23
2.1
2
Contents
CVX050/100
Description
2
2
2
2
2
2
2
2
2
2
CVX050/100
Product Description
Application Description
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Page
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . .
SPD Series for Integration into Electrical
Distribution Equipment . . . . . . . . . . . . . . . . . . . . .
SPD Series for Mounting External to
Electrical Distribution Equipment . . . . . . . . . . . . .
SPD MAX Series Surge Protection . . . . . . . . . . . . .
SPC Surge Protective Device . . . . . . . . . . . . . . . . .
CVX050/100
Catalog Number Selection . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SP1 Surge Protective Device. . . . . . . . . . . . . . . . . .
SP2 Surge Protective Device. . . . . . . . . . . . . . . . . .
AEGIS Powerline Filters. . . . . . . . . . . . . . . . . . . . . .
Sag Ride-Through (SRT2). . . . . . . . . . . . . . . . . . . . .
Electronic Voltage Regulator (EVR) . . . . . . . . . . . . .
Power-Sure 800 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power-Suppress 100 . . . . . . . . . . . . . . . . . . . . . . . .
V3-T2-24
Residential/small business
Light industrial
Light commercial
Branch panel protection
OEM applications
Features, Benefits
and Functions
Optional Features
V3-T2-2
V3-T2-5
V3-T2-7
V3-T2-11
V3-T2-16
V3-T2-20
V3-T2-25
V3-T2-25
V3-T2-26
V3-T2-27
V3-T2-29
V3-T2-31
V3-T2-36
V3-T2-40
V3-T2-42
V3-T2-46
2.1
CVX050/100
2
CVX 050 - 240S
Per Phase Peak
Surge Current
050 = 50 kA
100 = 100 kA
2
2
2
2
2
2
2
Specification
50, 100
50
20 kA 1
100 kA
Single-phase voltages
200, 208, 220, 230, 240, 277, 380, 400, 440, 460, 480 Vac
Split-phase voltages
240 Vac
100/175, 110/190, 120/208, 127/220, 220/380, 230/400, 240/415, 277/480, 305/525, 347/600 Vac
2
2
2
2
2
2
200, 208, 220, 230, 240, 380, 400, 415, 440, 480, 525, 600 Vac
2
Protection modes
Number of ports
Specific energy
100 kJ/Ohm
Weight
Operating temperature
Vibration tested
2
2
2
2
2
2
2
Notes
1 480L, 600D and 600Y units rated 10 kA I .
n
2 DC models only available in 50 kA.
2
2
2
2
2
2
V3-T2-25
2.1
2
2
Model
UL 1449-3 VPR 1
MCOV
Nominal
System Voltage
L-L
L-N
L-G
N-G
L-L
L-N
L-G
N-G
CVX050
230L
320
640
320
1200
1200
1200
480L
550
1100
550
1800
4000
1800
240S
300
150
300
150
1200
700
1200
800
208Y
300
150
300
150
1200
700
1200
800
480Y
640
320
640
320
2500
1200
2000
1200
600Y
305/525, 347/600
840
420
840
420
2500
1500
2500
1500
240D
640
320
2000
1200
240H
240
300
150
150
640
1500
700
1200
700
480D
1100
550
3000
1800
600D
525, 600
1100
700
3000
2500
048DC
Direct current
48 Vdc 2
130
65
125DC
Direct current
125 Vdc 2
288
144
230L
320
320
320
1200
1200
1200
480L
550
550
550
1800
1800
1800
240S
300
150
150
150
1200
700
800
700
208Y
300
150
150
150
1000
600
700
700
480Y
640
320
320
320
1800
1200
1200
1200
600Y
305/525, 347/600
840
420
420
420
2500
1500
1500
1500
240D
640
320
1800
1200
240H
240
300
150
150
150
1200
700
700
700
480D
1100
550
3000
1800
Dimensions
2
2
2
4.75 (120.6)
3.39 (86.1)
2
2
Lid Removed
2
2
2
Section A-A
2
2
1.00 (25.4)
3.55 (90.2)
0.17 (4.3)
(4) Mounting Holes
Under Lid
Conduit Fitting
0.75 (19.0) Internal
Taper Pipe Threads
5.67 (144.0)
4.75 (120.6)
4.17 (106.0)
2.37 (60.2)
CVX100
2.1
Contents
Description
Page
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . .
SPD Series for Integration into Electrical
Distribution Equipment . . . . . . . . . . . . . . . . . . . . .
SPD Series for Mounting External to
Electrical Distribution Equipment . . . . . . . . . . . . .
SPD MAX Series Surge Protection . . . . . . . . . . . . .
SPC Surge Protective Device. . . . . . . . . . . . . . . . . .
CVX050/100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SP1 Surge Protective Device
Catalog Number Selection . . . . . . . . . . . . . . . . .
Technical Data and Specifications. . . . . . . . . . . .
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SP2 Surge Protective Device . . . . . . . . . . . . . . . . . .
AEGIS Powerline Filters . . . . . . . . . . . . . . . . . . . . . .
Sag Ride-Through (SRT2) . . . . . . . . . . . . . . . . . . . . .
Electronic Voltage Regulator (EVR) . . . . . . . . . . . . .
Power-Sure 800 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power-Suppress 100 . . . . . . . . . . . . . . . . . . . . . . . .
V3-T2-2
V3-T2-5
V3-T2-7
V3-T2-11
V3-T2-16
V3-T2-20
V3-T2-24
V3-T2-28
V3-T2-28
V3-T2-28
V3-T2-29
V3-T2-31
V3-T2-36
V3-T2-40
V3-T2-42
V3-T2-46
2
2
2
2
2
2
2
2
2
2
Features
Installation and operation of
the SP1 is simple. The unit
comes pre-wired with 24.00
inches of 10-gauge wire and
is mounted via the half-inch
nipple that is molded into its
enclosure. Wall or DIN rail
mounting can also be
accomplished with the
addition of an optional kit.
When powered, the units
light-emitting diode (LED)
indicator reports the status of
the protection elements and
is active when all of them are
intact and providing
protection. Any loss of
protection is signaled when
the LED extinguishes.
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-27
2.1
2
2
SP1 - XXXX
2
Series
Voltage Code
SP1
240S
208Y
480Y
600Y
240D
480D
600D
2
2
2
2
SP1
Dimensions
Approximate Dimensions in Inches (mm)
SP1
Description
Ratings
50 kA
2
2
2
2
2
2
1/2" (12.7)
Straight Pipe Thread
1.35
(34.3)
200 kA
SPD type
.79 (20.1)
120/240
Three-phase wye
Three-phase delta
3.95
(100.3)
Protection modes
Single split-phase and three-phase wye
L-N, L-L
Three-phase delta
L-G, L-L
SP1-480Y
SP1-600Y
SP1-240D
SP1-480D
SP1-600D
2.89
(73.4)
NEMA 4
Operating temperature
20 C to 50 C (4 F to 122 F)
Operating humidity
595%, noncondensing
Operating altitude
Up to 16,000 ft (5000 m)
Warranty
2 years
Catalog Number
L-N
L-G
L-L
SP1-240S
600
N/A
1000
SP1-208Y
600
N/A
1000
SP1-480Y
1200
N/A
2000
SP1-600Y
1500
N/A
2500
SP1-240D
N/A
1000
1000
SP1-480D
N/A
2000
2000
SP1-600D
N/A
2500
2500
50/60 Hz
Protection Mode
V3-T2-28
2.46
(62.5)
2.1
Contents
Description
Page
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . .
SPD Series for Integration into Electrical
Distribution Equipment . . . . . . . . . . . . . . . . . . . . .
SPD Series for Mounting External to
Electrical Distribution Equipment . . . . . . . . . . . . .
SPD MAX Series Surge Protection . . . . . . . . . . . . .
SPC Surge Protective Device. . . . . . . . . . . . . . . . . .
CVX050/100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SP1 Surge Protective Device . . . . . . . . . . . . . . . . . .
SP2 Surge Protective Device
Product Selection . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . .
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AEGIS Powerline Filters . . . . . . . . . . . . . . . . . . . . . .
Sag Ride-Through (SRT2) . . . . . . . . . . . . . . . . . . . . .
Electronic Voltage Regulator (EVR) . . . . . . . . . . . . .
Power-Sure 800 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power-Suppress 100. . . . . . . . . . . . . . . . . . . . . . . . .
V3-T2-2
V3-T2-5
V3-T2-7
V3-T2-11
V3-T2-16
V3-T2-20
V3-T2-24
V3-T2-27
V3-T2-30
V3-T2-30
V3-T2-30
V3-T2-31
V3-T2-36
V3-T2-40
V3-T2-42
V3-T2-46
Application Description
By providing surge
protection, the SP2 can
suppress the transients that
are prevalent throughout the
power distribution system to
support reliable operations in
applications including:
HVAC systems
Control panels
Automation cabinets
Pumping systems
Lighting systems
Commercial facilities
Food processing
Warehouses
Retail facilities
Manufacturing operations
2
2
2
2
2
2
2
2
2
2
Ease of installation
Compact design allows
for easy installation on an
electrical panel or meter
socket, or integrated into
control cabinets
Type 1 UL 1449 Third
Edition listed SP2s are
easily selected and
installed on the loadside
or lineside of the service
entrance overcurrent
protective device
Thermal disconnect
technology eliminates the
need for additional
overcurrent protection
Compact UV-resistant
NEMA 4X enclosure for
indoor or outdoor
applications
LED status indicators
provide surge protection
status at a glancegreen
when good, red to replace
Voltage-specific models
protect electrical systems
and equipment, improving
performance by more than
110% over one-size-fitsall economy surge
arresters
Compact enclosure takes
up less space and can be
installed in tight spaces
Can be used on singlephase, split-phase, wye,
delta, and high-leg delta
systems
All SP2 devices are
individually marked with a
serial number for easy
tracking and identification
Two-year warranty
IEEE C62.41.1
IEEE C62.41.2
IEEE C62.43-2005
IEEE C62.45-2002
IEEE C62.48-2005
IEEE C62.62-2010
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-29
2.1
Product Selection
SP2
Nominal
System
Voltage
Maximum Continuous
Operating AC Voltage
(MCOV)
System
Type
Voltage
Protection
Ratings (VPR)
120
150
Single-phase, two-wire
240
320
Single-phase, two-wire
120/240
150
240
2
2
2
Connection
Points
Catalog
Number
700 LN
SP2-120
1200 LN
SP2-240
Split-phase, three-wire
SP2-240S
320
SP2-240D
480
550
SP2-480D
120/208
150
SP2-208Y
277/480
320
SP2-480Y
347/600
420
SP2-600Y
SP2
Description
Specification
Markets
Product warranty
2 years
System types
Installation
MCOV
LN protection
LL protection
Yes
LG protection
Protection
SCCR
200 kA
10 kA
45 kA per phase
2
2
2
Response time tA
<25 ns
Overcurrent device (if required by local code) Circuit breaker or fuse sized to protect wires per
local codes
Frequency
50/60 Hz
Conductor gauge/length
Mounting
Enclosure rating
IP20 (finger-safe)
Install location
Indoor/outdoor
Circuit location
Lineside/loadside
Operating temperature
40 C to +65 C
12,000 ft (3657.6 m)
Weight
17 oz (476 g)
2
2
Dimensions
SP2 Enclosure
1.06 (26.9)
Diameter
1.69
(42.9)
3.38
(85.9)
1.69
(42.9)
2.06
(52.3)
2.06
(52.3)
4.13
(104.9)
3.19
(81.0)
4.06
(103.1)
" NPS
0.87
(22.1)
2
2
V3-T2-30
2.1
Contents
AEGIS Solutions
Description
Page
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . .
SPD Series for Integration into Electrical
Distribution Equipment . . . . . . . . . . . . . . . . . . . . .
SPD Series for Mounting External to
Electrical Distribution Equipment . . . . . . . . . . . . .
SPD MAX Series Surge Protection . . . . . . . . . . . . .
SPC Surge Protective Device. . . . . . . . . . . . . . . . . .
CVX050/100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SP1 Surge Protective Device . . . . . . . . . . . . . . . . . .
SP2 Surge Protective Device . . . . . . . . . . . . . . . . . .
AEGIS Powerline Filters
Features, Benefits and Functions . . . . . . . . . . . .
Standards and Certifications. . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . . .
Technical Data and Specifications. . . . . . . . . . . .
Sag Ride-Through (SRT2) . . . . . . . . . . . . . . . . . . . . .
Electronic Voltage Regulator (EVR) . . . . . . . . . . . . .
Power-Sure 800 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power-Suppress 100 . . . . . . . . . . . . . . . . . . . . . . . .
V3-T2-2
V3-T2-5
V3-T2-7
V3-T2-11
V3-T2-16
V3-T2-20
V3-T2-24
V3-T2-27
V3-T2-29
V3-T2-32
V3-T2-33
V3-T2-33
V3-T2-34
V3-T2-36
V3-T2-40
V3-T2-42
V3-T2-46
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Application Description
Instrumentation
Water treatment facilities
Pulp and paper operations
Refrigeration and heating
plants
Petrochemical and refinery
Food processing
Textiles
Automotive assembly
Manufacturing operations
Programmable logic
controllers (PLCs)
Scanning devices
Automatic teller machines
(ATMs)
Cash registers
Alarm systems
Microprocessor-controlled
OEM products
Robotics
CAD/CAM systems
Control equipment
Medical electronics and
devices
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-31
2.1
2
2
2
2
2
2
2
AEGIS Summary
Specifications
PH
PV
CF
CN
Voltage
120/240 Vac
120/240 Vac
120/240 Vac
24/48 Vdc
120/240 Vac
24/48 Vdc
Current range
320 A
15 A
1060 A
30 A
DIN mounting
Yes
Yes
Yes 1
No
Yes
Yes
Yes 2
Yes 2
No
2
2
2
Filtering
Yes
Yes
Yes
75 dB
50 dB
40 dB
N/A
Yes
Yes
Yes
Yes
60/30
40/20
80/40
80/40
5 kA
5 kA
5 kA
5 kA
330/400
330/400
500/500
500/500
5 kA
5 kA
10 kA
10 kA
Alarm contacts
Yes
No
Yes 4
No
10/15
10/15
5/10
5/10
No
No
Yes 4
No
2
2
Three-Wire Design has Normal and Common Mode Protection (L-N, L-G, N-G)
Primary
Surge
Protection
2
2
Power
Input
2
2
2
2
2
2
High
Frequenc
y
Series
Blocking
Inductors
High
Performance
Tracking Filter
Secondary
Surge
Protection
Optional
Form C
Contacts 5
Power
Output
Normal
Mode
Normal
Mode
N
G
Status
Indicator
Lights
LED
Form C
L
N
Common
Mode
Common
Mode
Notes
1 Optional on 10 A and 30 A models only.
2 120 Vac models only.
3 Ratings shown for 120 Vac models, other voltages listed in Technical Data.
4 Optional on 30 A and 60 A models only.
5 Available on the PH Series only.
2
V3-T2-32
2.1
AEGIS Products
IEEE C62.41.1
IEEE C62.41.2
IEEE C62.43-2005
IEEE C62.45-2002
IEEE C62.48-2005
IEEE C62.62-2010
2
2
2
2
2
2
2
2
AEGIS
2
AG
Product
Family/OEM
AG
2
2
Protection/Filtering
PH = Premium protection
with hybrid filtering
Voltage
120 = 120 Vac
240 = 240 Vac
PV = Premium protection
with filtering
CF = Critical protection
with filtering
CN = Critical protection
without filtering
Amperage
03 = 3 A
05 = 5 A
10 = 10 A
15 = 15 A
20 = 20 A
01 = 1 A
03 = 3 A
05 = 5 A
10 = 10 A
15 = 15 A
30 = 30 A
60 = 60 A
Options
2
2
2
DIN
DIN2
CP
RJ
=
=
=
=
DIN mount 1
DIN2 mount 2
Compact 3
Telcom protection
and Form C status
contacts 4
2
2
2
30 = 30 A
2
2
Notes
1 Not available for 10 A, 230 V or 240 V versions.
2 Only available for 10 A, 120 V or 240 V CF version.
3 Only available for 10 A, 120 V CF version.
4 Only available for 30 A and 60 A CF version.
2
2
2
2
2
2
2
2
2
V3-T2-33
2.1
2
AEGIS PH and PV
PH 120 Vac
PH 240 Vac
PV 120 Vac
Specifications
3, 5, 10, 15, 20 A
3, 5, 10, 15, 20 A
1, 3, 5 A
1, 3, 5 A
DIN mounting
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Filtering
Yes
Yes
Yes
Yes
75 dB
75 dB
50 dB
50 dB
Yes
Yes
Yes
Yes
60/30
60/30
40/20
40/20
5 kA
5 kA
5 kA
5 kA
330/400/330
600/700/600
330/400/330
600/700/600
MCOV
150
275
150
275
5 kA
5 kA
5 kA
5 kA
Alarm contacts
Yes
Yes
No
No
10/15
10/15
10/15
10/15
No
No
No
No
2
2
2
2
PV 240 Vac
AEGIS CF
CF 24 Vdc
CF 48 Vdc
CF 120 Vac
CF 240 Vac
Specifications
10 A
10 A
10 A
10 A
10 A
10 A
30 A
60 A
10 A
10 A
30 A
DIN mounting
Yes
No
Yes
No
Yes
No
Yes 1
Yes 1
Yes
No
No
Yes 1
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Filtering
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
40 dB
40 dB
40 dB
40 dB
40 dB
40 dB
40 dB
40 dB
40 dB
40 dB
40 dB
40 dB
LG, LN and NG
protection modes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
6/2
6/2
20/6
20/6
30/10
40/20
80/40
80/40
30/10
24/8
56/24
56/24
UL nominal discharge
current (In)
N/A
N/A
N/A
N/A
3 kA
5 kA
5 kA
5 kA
3 kA
N/A
N/A
N/A
N/A
N/A
N/A
N/A
500/500/500
500/500/500
500/500/500
500/500/500
900/800/900
N/A
N/A
N/A
MCOV
30
30
50
50
150
150
150
150
275
275
275
275
Short-circuit current
rating (SCCR)
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
Alarm contacts
No
No
No
No
No
No
No
No
No
No
No
No
Standard warranty /
registered warranty (years)
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
Communication line
protection (UL 497A)
No
No
No
No
No
No
Yes 1
Yes 1
No
No
Yes 1
Yes 1
2
2
2
2
2
Note
1 Optional.
2
2
2
2
V3-T2-34
60 A
2.1
AEGIS CN
24 Vdc
48 Vdc
120 Vac
240 Vac
Specifications
30 A
30 A
30 A
30 A
DIN mounting
No
No
No
No
Yes
Yes
Filtering
No
No
No
No
N/A
N/A
N/A
N/A
Yes
Yes
Yes
Yes
20/6
46/20
80/40
56/24
N/A
N/A
5 kA
N/A
N/A
N/A
500/500/500
N/A
MCOV
30
50
150
275
10 kA
10 kA
10 kA
10 kA
Alarm contacts
No
No
No
No
5/10
5/10
5/10
5/10
No
No
No
No
2
2
2
2
2
2
2
2
2
2
Model
10 kHz
100 kHz
1 MHz
10 MHz
100 MHz
Maximum
Attenuation
Frequency
AGPH120AG
30 dB
74 dB
76 dB
37 dB
36 dB
AGPV120AG
27 dB
56 dB
55 dB
36 dB
28 dB
66 dB at 0.085 MHz
AGCF12010-CP
16 dB
35 dB
62 dB
40 dB
50 dB
68 dB at 1.25 MHz
AGCF12010-DIN
16 dB
35 dB
56 dB
29 dB
51 dB
66 dB at 0.7 MHz
AGCF12010
17 dB
35 dB
64 dB
33 dB
51 dB
64 dB at 1.0 MHz
AGCF12030
24 dB
44 dB
58 dB
42 dB
53 dB
67 dB at 0.6 MHz
AGCF12060
20 dB
48 dB
53 dB
29 dB
46 dB
69 dB at 0.4 MHz
2
2
2
2
2
2
AGPH120AG
AGPV120AG
AGCF12010
AGCF12010-DIN
AGCF12010-CP
AGCF12030AGx
AGCF12060AGx
AGCN12030
IEEE Category A
100 kHz ring wave
6000 V, 200 A
25 V
30 V
150 V
300 V
300 V
150 V
90 V
400 V
IEEE Category B
100 kHz ring wave
6000 V, 500 A
35 V
40 V
330 V
400 V
400 V
330 V
230 V
500 V
IEEE Category B
combination wave
6000 V, 3000 A
(UL 1449-3 VPR)
360 V
370 V
470 V
480 V
460 V
460 V
450 V
460 V
2
2
2
2
2
2
Note
1 All tests conducted on 120 Vac units.
2
2
2
2
2
2
Volume 3Power Distribution and Control Assemblies CA08100004EAugust 2016 www.eaton.com
V3-T2-35
2.1
2
Contents
Description
2
2
2
2
2
2
2
2
2
2
2
Product Description
2
2
2
2
2
2
2
2
2
2
2
2
2
Input A
Input A
Input A
600
400
200
0
-200
-400
-600
Voltage Sags
Generation
1. Fault occurs on
the transmission
or distribution
system
Transmission
Distribution
6
5
Feeder
Breakers
End
User
2. Creates a sag
event for all
users on the
system
4
3
2
1
End User
50 0 0 5
2 1
20 10 6
2
V3-T2-36
10
V3-T2-37
V3-T2-37
V3-T2-38
V3-T2-39
V3-T2-40
V3-T2-42
V3-T2-46
V3-T2-11
V3-T2-16
V3-T2-20
V3-T2-24
V3-T2-27
V3-T2-29
V3-T2-31
30
V3-T2-7
60
Page
V3-T2-2
V3-T2-5
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . .
SPD Series for Integration into Electrical
Distribution Equipment . . . . . . . . . . . . . . . . . . . . .
SPD Series for Mounting External to
Electrical Distribution Equipment . . . . . . . . . . . . . .
SPD MAX Series Surge Protection . . . . . . . . . . . . . .
SPC Surge Protective Device . . . . . . . . . . . . . . . . . .
CVX050/100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SP1 Surge Protective Device . . . . . . . . . . . . . . . . . .
SP2 Surge Protective Device . . . . . . . . . . . . . . . . . .
AEGIS Powerline Filters . . . . . . . . . . . . . . . . . . . . . .
Sag Ride-Through (SRT2)
Application Description . . . . . . . . . . . . . . . . . . . .
Features, Benefits and Functions . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . .
Electronic Voltage Regulator (EVR) . . . . . . . . . . . . . .
Power-Sure 800. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power-Suppress 100 . . . . . . . . . . . . . . . . . . . . . . . . .
Application Description
Equipment or processes:
Semi-conductor
manufacturers
Communications
Steel mills
Petroleum and chemical
processing
Health care
Paper mills
Automotives
Textile
Printing
Plastics
Other manufacturing
Manufacturing process
controllers
Variable speed drives
Robotics
Motor conductor
Telephone systems
HID lighting
HVAC controls
Medical equipment
Computers
3-Phase
Utility
Supply
3-Phase Compensating
Voltage
Secondary
Distribution
Transformer
Primary
3-Phase
Load
Voltage
Injection
Transformer
Bypass Circuit
SRT2 Input
SRT2 Output
Voltage Source
Inverter
Complete correction
of single-phase voltage
sags down to 63% for
30 seconds
Partial correction of threephase sags down to 50%
for 30 seconds
Correction of utility voltage
unbalance (from network
side of transformer)
Attenuation of voltage
flicker
2.1
2
Continuous Regulation
The Sag Ride-Through is an
active voltage conditioner.
This means it will constantly
respond to voltage sags and
swells in the +/10% range
with a regulated output in the
+/1% range. The SRT2 can
be applied to the main service
entrance, at branch locations
or in front critical loads. The
SRT2 provides an outstanding
return on investment. It
delivers operation productivity
that is just not possible with
traditional tap switching or
ferroresonant technologies.
The SRT2 consists of a
voltage source inverter,
bypass circuit and an injection
transformer connected in
series between the incoming
utility supply and the load, as
shown in the figure below.
For the standard sag
correcting model, the
injection transformer consists
of a boost component. The
SRT2 monitors the incoming
supply voltage and when it
deviates from the nominal
voltage level the SRT2 inserts
an appropriate compensating
voltage using the IGBT
inverter and series injection
transformer. Energy is
sourced from the supply
during this time. This
regulates the load voltage
to its nominal value,
thus eliminating voltage
disturbances from the utility
supply affecting the load.
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-37
2.1
2
2
2
2
Product Selection
SRT2 1
Load Capacity at
Nominal Voltage
480 V (kVA) 2
Terminal
Cabinet 3
Fault Capacity
(kVA)
System
Efficiency (%)
Cabinet Dimensions H x W x D
in Inches (mm)
Catalog
Number 4
SRT20150480AA
150
No
40
97.5
3.8
18
150
Yes
40
97.5
3.8
18
SRT20150480AA-TC
225
No
40
97.7
5.2
18
SRT20225480AA
225
Yes
40
97.7
5.2
18
SRT20225480AA-TC
300
No
40
98.0
6.1
18
SRT20300480AA
300
Yes
40
98.0
6.1
18
SRT20300480AA-TC
SRT20450480AA
2
2
450
No
40
98.2
8.0
36
450
Yes
40
98.2
8.0
36
SRT20450480AA-TC
600
No
40
98.4
9.8
36
SRT20600480AA
600
Yes
40
98.4
9.8
36
SRT20600480AA-TC
750
No
40
98.4
12.2
54
SRT20750480AA
750
Yes
40
98.4
12.2
54
SRT20750480AA-TC
900
No
40
98.5
13.2
54
SRT20900480AA
1200
No
40
98.5
18.1
72
SRT21200480AA
1500
No
50
98.7
20.2
90
SRT21500480AA
1800
No
50
98.8
22.1
108
SRT21800480AA
2
2
2
S3
2
2
2
AC
Supply
2
2
2
2
2
2
Load
S1
SPD
S2
SRT2
Note: A terminal cabinet may be needed if a bypass cabinet is not used. SRT2 units 900 kVA and
larger do not require a terminal cabinet; however, an external three-breaker mechanical bypass with
integrated surge protection is recommended.
Notes
1 For 50 Hz international applications, consult factory.
2 480 V is standard. If additional voltage is needed, consult factory.
3 Eaton external three-breaker maintenance bypass cabinet is recommended. If a bypass is not used, a terminal cabinet may be required. Contact factory.
4 TC in the model number denotes terminal cabinet, which is not required for units of 900 kVA and larger.
2
2
2
2
2
2
V3-T2-38
2.1
SRT2 Specifications
Features
Specifications
Load Capacity
Capacity
2
2
Input Supply
480 V
Voltages up to 36 kV available as custom applications 1
Fault capacity
10% continuous
1%
2.5%
<250 s
<0.25 cycle
90% nominal
<4% typical
Efficiency of system
125%
150%
500%
2000%
<0.5 ms
<2.5% typical
Enclosure rating
NEMA 1, IP20
2
2
2
Bypass
Capacity
Maximum overload capacity (in bypass):
For 10 minutes
For 1 minute
For 1 second
For 200 milliseconds
Transfer time:
Inverter to bypass
Equivalent series impedance (in bypass)
Interface
Access protocol
Environmental
0 C
40 C
Temperature derating
Cooling:
Inverter
Transformer
Forced ventilation
Fan assisted ventilation
Humidity
<95%, noncondensing
EMC emissions
CISPR 22 level G
Noise
65 dBA
Warranty
1 year
2
2
Note
1 480 V is standard. If additional voltage is needed, consult factory.
2
Volume 3Power Distribution and Control Assemblies CA08100004EAugust 2016 www.eaton.com
V3-T2-39
2.1
2
Contents
Description
Page
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . .
SPD Series for Integration into Electrical
Distribution Equipment . . . . . . . . . . . . . . . . . . . . .
SPD Series for Mounting External to
Electrical Distribution Equipment . . . . . . . . . . . . .
SPD MAX Series Surge Protection . . . . . . . . . . . . .
SPC Surge Protective Device . . . . . . . . . . . . . . . . .
CVX050/100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SP1 Surge Protective Device. . . . . . . . . . . . . . . . . .
SP2 Surge Protective Device. . . . . . . . . . . . . . . . . .
AEGIS Powerline Filters. . . . . . . . . . . . . . . . . . . . . .
Sag Ride-Through (SRT2). . . . . . . . . . . . . . . . . . . . .
Electronic Voltage Regulator (EVR)
Catalog Number Selection . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . .
2
2
2
2
2
2
2
V3-T2-2
V3-T2-5
V3-T2-7
V3-T2-11
V3-T2-16
V3-T2-20
V3-T2-24
V3-T2-27
V3-T2-29
V3-T2-31
V3-T2-36
V3-T2-41
V3-T2-41
2
2
Product Description
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
The Solution
Prior to installing an expensive
solution, Eaton encourages
customers to monitor
incoming voltage to
determine if voltage
regulation is a problem.
The local utility may also be
able to provide information
on voltage expected at
the facility.
Using a meter, it can quickly
be determined if a voltage
regulation problem or
brownout condition exists.
The appropriate solution
would be an EVR. EVRs can
be installed at the service
entrance, branch panel or
at critical loads.
Eatons EVR is a solid-state
tap changing power
conditioner designed to
protect against brownouts
and long duration voltage
regulation problems.
2
V3-T2-40
2.1
EVR
Weight
Lb
BTUs/
hr
Bypass
010
010
015
015
025
030
045
050
075
100
125
150
225
300
500
440
520
520
600
870
890
950
1,176
1,575
2,014
2,137
2,240
3,300
4,000
5,500
1,025
1,205
1,540
1,540
2,560
3,090
4,600
7,332
9,514
11,833
14,748
17,698
23,000
30,750
51,250
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Metering
No
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Nominal Input
Voltage
(Delta Input:
L, L, L, G)
208D = 208
240D = 240
400D = 400
480D = 480
600D = 600
2
2
2
Surge Protection
X = No
S = Yes
2
2
Frequency
A = 60 Hz
B = 50 Hz
Nominal Output
Voltage
(Wye Output:
L, L, L, N, G)
2
2
208Y = 120/208
400Y = 230/400
480Y = 277/480
600Y = 347/600
2
2
Description
Technology
Input voltages
Output voltage
3% of nominal
Response time
1/2 cycle
Frequency
60 Hz, 3%
Efficiency
97% typical
Line regulation
2
2
2
2
2
2
Load regulation
Correction time
Harmonic distortion
Less than 1.0% added to the output waveform under any dynamic linear loading conditions
presented to the line regulator
Noise attenuation
Common mode
Normal mode
146 dB
3 dB down at 1000 Hz, 40 dB/decade to below 50 dB with resistive load
Turn-on characteristics
When energized, voltage overshoot will be less than 5% of nominal for 1 cycle or less
Overload rating
Ambient rating
10 to 40 C
Monitoring
Three green LEDs (phase power on indication), one red LED (alert indication)
CVX 50 kA SPD device 50 kVA and below, CVX 100 kA SPD device 75 kVA and above
Input breaker
Bypass switch
Metering (optional)
Standard metering (IQ 130)voltage and current with minimum and maximum
Warranty
2
2
2
2
Premium metering (IQ 150)voltage, current, frequency, power, energy, PF, with minimum
and maximum, communications capabilities
1-year parts
Notes
1 Bypass is standard on 50 kVA and larger units and an option on 45 kVA and smaller units. The B is not included in the part number for
units 50 kVA and larger.
All weights are approximate. Monitor option includes main input circuit breaker.
Refer to PAD for pricing and availability.
2
V3-T2-41
2.1
2
Contents
Power-Sure 800
Description
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Page
Introduction
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . .
SPD Series for Integration into Electrical
Distribution Equipment . . . . . . . . . . . . . . . . . . . . .
SPD Series for Mounting External to
Electrical Distribution Equipment . . . . . . . . . . . . .
SPD MAX Series Surge Protection . . . . . . . . . . . . .
SPC Surge Protective Device . . . . . . . . . . . . . . . . .
CVX050/100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SP1 Surge Protective Device. . . . . . . . . . . . . . . . . .
SP2 Surge Protective Device. . . . . . . . . . . . . . . . . .
AEGIS Powerline Filters. . . . . . . . . . . . . . . . . . . . . .
Sag Ride-Through (SRT2). . . . . . . . . . . . . . . . . . . . .
Electronic Voltage Regulator (EVR) . . . . . . . . . . . . .
Power-Sure 800
Catalog Number Selection . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power-Suppress 100 . . . . . . . . . . . . . . . . . . . . . . . .
V3-T2-5
V3-T2-7
V3-T2-11
V3-T2-16
V3-T2-20
V3-T2-24
V3-T2-27
V3-T2-29
V3-T2-31
V3-T2-36
V3-T2-40
V3-T2-43
V3-T2-44
V3-T2-45
V3-T2-45
V3-T2-46
Power-Sure 800
Product Description
Application Description
Features
2
2
Superior isolation
Tight voltage regulation
High immunity to distortion
Lightning and surge
protection
Protection against power
interruptions
Power factor correction
Bi-directional harmonic
filtering
K-30 rated design
Warranty: two years
2
2
2
2
2
V3-T2-42
UL 1012, UL 544
and cUL listed
Meets ANSI standards for
computers with inputs as
low as 50% of nominal
2.1
Power-Sure 800
T800 X - XXXXX X X - X
Configuration
R = Receptacles
P = Hardwired wall-/panel-mount
F = Hardwired floor-mount
VA rating
01000
01500
01600
02000
02100
02500
03000
03500
03501
05000
07500
08000
10000
15000
20000
25000
Option/Frequency
Blank = 60 Hz
5
= 50 Hz
Code
No. of Output
Panels (Max. 4)
A
B
C
D
E
F
G
H
I
J
K
L
M
N
P
R
S
T
U
V
W
X
Y
1
1
1
1
1.5
1
1
1
1
1.5
1.5
1
1.5
1
1
1
1
1
1
1
1
1
1
NEMA
Volts
(1) 5-15R
(2) 5-15R
(1) 5-20R
(2) 5-20R
(1) 5-30R
(1) 6-15R
(2) 6-15R
(1) 6-20R
(2) 6-20R
(1) 6-30R
(1) 6-50R
(1) 14-20R
(1) 14-30R
(1) L5-15R
(2) L5-15R
(1) L5-20R
(1) L5-30R
(1) L6-15R
(2) L6-15R
(1) L6-20R
(1) L6-30R
(1) L14-20R
(1) L14-30R
120
120
120
120
120
208/240
208/240
208/240
208/240
208/240
208/240
120/240
120/240
120
120
120
120
208/240
208/240
208/240
208/240
120/240
120/240
Amps
2
2
2
15
15
20
20
30
15
15
20
20
30
50
20
30
15
15
20
30
15
15
20
30
20
30
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-43
2.1
2
2
2
2
Product Selection
Input Voltage
Output Voltage
Input Interface
Output Interface
Part Number
120
120
5-15P
(4) 5-20R
T800R-01000
1600/1200
120
120
5-15P
(4) 5-20R
T800R-01600
2100/1500
120
120
5-20P
(4) 5-20R
T800R-02100
2500/1750
120
120
5-30P
(4) 5-20R
T800R-02500
3500/2450
120
120/240
5-50P
(4) 5-20R
T800R-03500
3500/2450
208/240
120/240
6-20P
(4) 5-20R
T800R-03501
5000/3500
208/240
120/240
Hardwired
Custom 1
T800R-05000
7500/5250
208/240
120/240
Hardwired
Custom 1
T800R-07500
10,000/7000
208/240
120/240
Hardwired
Custom 1
T800R-10000
15,000/10,500
208/240
120/240
Hardwired
Custom 1
T800R-15000
Range 1 24
Range 3 5
Hardwired
Hardwired
T800P-00500
750/750
Range 1 24
Range 3 5
Hardwired
Hardwired
T800P-00750
1000/1000
Range 1
24
Hardwired
Hardwired
T800P-01000
1500/1500
Range 1 24
Range 3 5
Hardwired
Hardwired
T800P-01500
2000/2000
Range 1 24
Range 3 5
Hardwired
Hardwired
T800P-02000
3000/3000
Range 1 24
Range 3 5
Hardwired
Hardwired
T800P-03000
5000/5000
Range 1 24
Range 3 5
Hardwired
Hardwired
T800P-05000
8000/8000
Range 2 34
Range 3 5
Hardwired
Hardwired
T800P-08000
10,000/10,000
Range 2 34
Range 3 5
Hardwired
Hardwired
T800P-10000
Range 3
Range 1 24
Range 3 5
Hardwired
Hardwired
T800F-05000
8000/8000
Range 2
34
Range 3 5
Hardwired
Hardwired
T800F-08000
10,000/10,000
Range 2 34
Range 3 5
Hardwired
Hardwired
T800F-10000
15,000/15,000
Range 2 34
Range 3 5
Hardwired
Hardwired
T800F-15000
20,000/20,000
Range 2 34
Range 3 5
Hardwired
Hardwired
T800F-20000
25,000/25,000
Range 2 34
Range 3 5
Hardwired
Hardwired
T800F-25000
2
2
2
Notes
1 See Catalog Numbering Selection on Page V3-T2-43; 5 panels available for distribution; HW output utilizes 1 panel, other 4 panels can be used for receptacle interface or cabling.
2 Range 1: 120/208/240/480.
3 Range 2: 208/240/480.
4 Input and output voltage is field configurable; units will ship from the factory configured as follows: Range 1120 V (input/output); Range 2240 V (input/output).
5 Range 3: 120/208/240.
2
2
2
2
2
2
2
2
V3-T2-44
2.1
Dimensions
Galvanic isolation: NEC
250.5d, 0.001 PF
Surge protection: 330 V
let-through voltage when
tested to ANSI/IEEE
62.41-Cat B3
Common mode noise
attenuation: 140 dB
Transverse mode noise
attenuation: 120 dB
Reliability: 200,000 hours
(MTBF)
Audible noise: 5256 dB
measured at 1 meter,
A scale
Efficiency: approximately
92% at full load
Operating temperature:
20 C to +40 C
2
Power-Sure 800 Models
Dimensions, W x D x H
Weight, Lb (kg)
Part Number
46 (21)
T800R-01000
62 (28)
T800R-01600
65 (29)
T800R-02100
68 (31)
T800R-02500
72 (33)
T800R-03500
73 (33)
T800R-03501
176 (80)
T800R-05000
210 (95)
T800R-07500
256 (116)
T800R-10000
314 (142)
T800R-15000
2
2
2
2
2
2
2
2
2
52 (24)
T800P-00500
60 (27)
T800P-00750
82 (37)
T800P-01000
106 (48)
T800P-01500
125 (57)
T800P-02000
157 (71)
T800P-03000
437 (198)
T800P-05000
495 (225)
T800P-08000
537 (244)
T800P-10000
2
2
407 (185)
T800F-05000
465 (211)
T800F-08000
507 (230)
T800F-10000
830 (376)
T800F-15000
950 (431)
T800F-20000
1070 (485)
T800F-25000
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-45
2.1
2
Contents
Description
2
2
2
2
2
2
2
2
2
2
Introduction
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . .
SPD Series for Integration into Electrical
Distribution Equipment . . . . . . . . . . . . . . . . . . . . .
SPD Series for Mounting External to
Electrical Distribution Equipment . . . . . . . . . . . . . .
SPD MAX Series Surge Protection . . . . . . . . . . . . . .
SPC Surge Protective Device . . . . . . . . . . . . . . . . . .
CVX050/100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SP1 Surge Protective Device . . . . . . . . . . . . . . . . . .
SP2 Surge Protective Device . . . . . . . . . . . . . . . . . .
AEGIS Powerline Filters . . . . . . . . . . . . . . . . . . . . . .
Sag Ride-Through (SRT2) . . . . . . . . . . . . . . . . . . . . .
Electronic Voltage Regulator (EVR) . . . . . . . . . . . . . .
Power-Sure 800. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power-Suppress 100
Standards and Certifications . . . . . . . . . . . . . . . .
Catalog Number Selection. . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . .
2
2
2
Power-Suppress 100
Product Description
Application Description
Features
Eatons Power-Suppress
100 ultra-isolator noise
suppressors protect sensitive
equipment from electrical
noise disturbances. Using
exclusive double shielding
techniques, the PowerSuppress 100 blocks all forms
of electrical noise including
radio frequency interface
(RFI)/ electromagnetic
interference (EMI), over a
broad range of frequencies.
Furthermore, the noise
suppression is achieved
without impeding normal
power flow.
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-46
Page
V3-T2-5
V3-T2-7
V3-T2-11
V3-T2-16
V3-T2-20
V3-T2-24
V3-T2-27
V3-T2-29
V3-T2-31
V3-T2-36
V3-T2-40
V3-T2-42
V3-T2-47
V3-T2-47
V3-T2-47
V3-T2-48
V3-T2-48
2.1
2
2
2
2
Power-Suppress 100
2
T100
Connection Method
R = Receptacles
H = Hardwired
0500
0750
1000
1800
2400
2500
5000
5001
7500
7501
Option/Frequency
Blank = 60 Hz
5
= 50 Hz
Size (VA)
= 500 VA
= 750 VA
= 1000 VA
= 1800 VA
= 2400 VA
= 2500 VA
= 5000 VA
= 5000 VA 1
= 7500 VA
= 7500 VA 1
2
2
2
2
2
2
Product Selection
2
Power-Suppress 100 Models
Input Voltages 2
Output Voltages 2
Output VA 3
Catalog Number
2
2
Line-Cord/Receptacle Models
120
120
500
5-15P/(1) 5-20R2
T100R-0500
120
120
750
5-15P/(1) 5-20R2
T100R-0750
120
120
1000
5-15P/(1) 5-20R2
T100R-1000
120
120
1800
L5-20P/(2) 5-20R2
T100R-1800
120
120
2400
L5-30P/(2) 5-20R2
T100R-2400
120/240
120/240
500
Hardwired
T100H-0500
120/240
120/240
750
Hardwired
T100H-0750
120/240
120/240
1000
Hardwired
T100H-1000
120/240
120/240
1800
Hardwired
T100H-1800
120/240
120/240
2500
Hardwired
T100H-2500
120/240
120/240
5000
Hardwired
T100H-5000
240/480
120/240
5000
Hardwired
T100H-5001 1
120/240
120/240
7500
Hardwired
T100H-7500
240/480
120/240
7500
Hardwired
T100H-7501 1
2
2
2
2
2
2
2
Notes
1 Models T100H-5001 and T100H-7501 will ship configured to 240 V input and output voltage.
2 Input and output voltages can be field configured for either 120 Vac or 240 Vac, 240 Vac or 480 Vac, as indicated above.
3 500 VA to 7500 VA hardwired models will ship configured to 120 V input and output voltage.
2
2
2
V3-T2-47
2.1
2
2
Dimensions
Approximate Dimensions in Inches (mm)
Technical Specifications
Description
Specifications
Input voltage/frequency
Dimensions, W x D x H
Common-mode noise
Line-Cord/Receptacle Models
Normal-mode noise
65 dB at100 kHz
Overload capacity
Dielectric strength
Weight, Lb (kg)
Catalog Number
22 (10)
T100R-0500
28 (13)
T100R-0750
31 (14)
T100R-1000
Frequency
60 Hz 5%
54 (24)
T100R-1800
Impedance
36% typical
58 (26)
T100R-2400
Efficiency
9397% typical
22 (10)
T100H-0500
Harmonic distortion
28 (13)
T100H-0750
31 (14)
T100H-1000
54 (24)
T100H-1800
58 (26)
T100H-2500
86 (39)
T100H-5000
92 (42)
T100H-5001
Coil insulation
200 C
Temperature rise
Electromagnetic interference
Environments
116 (53)
T100H-7500
Description
Specifications
111 (50)
T100H-7501
Audible noise
Operating temperature
0 to 40 C
Storage temperature
20 to 50 C
2
2
2
Operating altitude
Operating humidity
Line-Cord Style
5-15P Input
Line Cord
8.00 (203.2)
Input Plug
6.49
(164.8)
Output Receptacle
5001000 VA
5-15P
5-20R duplex
1.8 kVA
L5-20P
2 x 5-20R duplex
2.4 kVA
L5-30P
2 x 5-20R duplex
10.28
(261.1)
Terminal Style
Input
Fuse
6.10
(154.9)
5-20R2
Output
Receptacles
500 VA1 kVA
11.10
(281.9)
5001000 VA Rear View
L5-20 Input
Line Cord
8.00 (203.2)
2
2
Input Fuse
10.49
(266.4)
2
2
Input Fuse
5-20R2 Output
Receptacles
1.82.4 kVA
0.50 (12.7)
Input/Output
Conduit Knockouts
2
2
Note
1 480 V available for 5 and 7.5 kVA models only.
2
2
V3-T2-48
2.2
Contents
Description
Page
Product Overview
Product Selection . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNIPUMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNIPAK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AUTOVAR 300 Automatic Power Factor Correction
Capacitor Systems . . . . . . . . . . . . . . . . . . . . . . .
AUTOVAR 600 Automatic Power Factor
Correction Capacitor Systems . . . . . . . . . . . . . .
AUTOVAR FilterLV Automatic Detuned Filter . . .
Transient-Free Static Switching Power Factor
Correction Units . . . . . . . . . . . . . . . . . . . . . . . . .
HCU2 Harmonic Correction Unit . . . . . . . . . . . . . .
V3-T2-50
V3-T2-50
V3-T2-51
V3-T2-54
2
2
2
2
V3-T2-63
V3-T2-67
V3-T2-74
V3-T2-81
V3-T2-83
2
2
2
2
2
Product Overview
Product Description
Eatons power factor
correction capacitors and
harmonic filters are an
essential part of modern
electric power systems.
Power factor correction
capacitors are the simplest
and most economical
means of increasing the
capacity of any power
system, minimizing energy
losses and correcting load
power factor. In addition,
power factor penalties can
be reduced and power quality
can be greatly enhanced.
Harmonic Filtering
As the world becomes more
dependent on electric and
electronic equipment, the
likelihood that the negative
impact of harmonic distortion
increases dramatically. The
efficiency and productivity
gains from these increasingly
sophisticated pieces of
equipment have a negative
side effectincreased
harmonic distortion in the
power lines. The difficult
thing about harmonic
distortion is determining the
cause. Once this has been
determined, the solution
can be easy. Active harmonic
filtering equipment will
mitigate specific harmonic
issues, and correct poor
power factor as well.
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-49
2.2
Product Selection
2
2
2
2
2
2
kvar 1
Weight in
Lb (kg)
Catalog
Number
240
1.5
3.1 (79.5)
7.9 (200.0)
1.1 (0.5)
643PCRMB
240
3.1 (79.5)
9.4 (238.0)
1.3 (0.6)
8B43PCRMB
240
240
240
240
240
2.5
3
4
5
6.3
3.1 (79.5)
3.5 (89.5)
3.1 (79.5)
3.5 (89.5)
3.1 (79.5)
9.4 (238.0)
9.4 (238.0)
7.9 (200.0)
12.3 (313.0)
9.4 (238.0)
1.3 (0.6)
1.8 (0.8)
1.1 (0.5)
2.6 (1.2)
1.3 (0.6)
1043PCRMB
12X43PCRMB
423PCRMB
2043PCRMB
6B23PCRMB
Nameplate
Voltage
kvar
240
12.5
3.5 (89.5)
480
15.0
3.5 (89.5)
480
16.7
480
Internal
Voltage
Rating
Weight in
Lb (kg)
Catalog
Number
3.3 (1.5)
12X23PHRMB
2.6 (1.2)
1543PHRMB
3.5 (89.5)
3.3 (1.5)
16S43PHRMBS
20.0
3.5 (89.5)
3.3 (1.5)
2043PHRMB
480
25.0
3.5 (89.5)
3.3 (1.5)
2543PHRMB
600
12.3
3.5 (89.5)
2.6 (1.2)
12A63PHRMB
600
14.7
3.5 (89.5)
3.3 (1.5)
14S63PHRMB
600
16.7
3.5 (89.5)
3.3 (1.5)
16S63PHRMB
240
7.5
3.1 (79.5)
9.4 (238.0)
1.3 (0.6)
7X23PCRMB
240
8.3
3.5 (89.5)
9.4 (238.0)
3.3 (1.5)
8B23PCRMB
240
10
3.5 (89.5)
9.4 (238.0)
2.0 (0.9)
1023PCRMB
240
12.5
3.5 (89.5)
12.3 (313.0)
2.6 (1.2)
12X23PCRMB
Dimensions
240
15
3.5 (89.5)
12.3 (313.0)
2.6 (1.2)
1523PCRMB
480
1.5
2.1 (53.0)
5.0 (125.8)
0.7 (0.3)
1X43PCRMA
480
2.5 (63.5)
5.5 (140.8)
0.9 (0.4)
243PCRMA
480
2.5
2.5 (63.5)
5.5 (140.8)
0.9 (0.4)
2X43PCRMA
480
2.5 (63.5)
5.5 (140.8)
0.9 (0.4)
343PCRMA
480
2.5 (63.5)
6.5 (165.8)
0.9 (0.4)
443PCRMA
480
2.5 (63.5)
6.5 (165.8)
0.9 (0.4)
543PCRMA
480
3.1 (79.5)
7.9 (200.0)
1.1 (0.5)
643PCRMB
480
7.5
3.1 (79.5)
7.9 (200.0)
1.1 (0.5)
7X43PCRMB
480
8.3
3.1 (79.5)
9.4 (238.0)
1.3 (0.6)
8B43PCRMB
480
3.1 (79.5)
9.4 (238.0)
1.3 (0.6)
943PCRMB
480
10
3.1 (79.5)
9.4 (238.0)
1.3 (0.6)
1043PCRMB
480
12.5
3.5 (89.5)
9.4 (238.0)
1.8 (0.8)
12X43PCRMB
480
15
3.5 (89.5)
9.4 (238.0)
1.8 (0.8)
1543PCRMB
480
18
3.5 (89.5)
12.3 (313.0)
2.6 (1.2)
1843PCRMB
480
20
3.5 (89.5)
12.3 (313.0)
2.6 (1.2)
2043PCRMB
480
25
3.5 (89.5)
12.3 (313.0)
2.6 (1.2)
2543PCRMB
600
3.1 (79.5)
9.4 (238.0)
1.3 (0.6)
563PCRMB
600
7.5
3.1 (79.5)
9.4 (238.0)
1.3 (0.6)
7X63PCRMB
600
10
3.1 (79.5)
9.4 (238.0)
1.3 (0.6)
1063PCRMB
600
12.5
3.5 (89.5)
9.4 (238.0)
1.8 (0.8)
12X63PCRMB
600
15
3.5 (89.5)
12.3 (313.0)
2.6 (1.2)
1563PCRMB
600
17.5
3.5 (89.5)
12.3 (313.0)
2.6 (1.2)
17X63PCRMB
600
20
3.5 (89.5)
12.3 (313.0)
3.3 (1.5)
2063PCRMB
600
25
3.5 (89.5)
15.3 (388.0)
3.3 (1.5)
2563PCRMB
Capacitor Cell
Note
1 kvar rating standard. Standard kvar tolerance is 0% to +5%.
Part number shown is for three-phase units. Up to 5 kvar at 480 V
quick disconnect terminals are standard. Above 5 kvar at 480 V (and on
all other voltages)cage clamp terminals are standard.
2
2
2
2
2
2
V3-T2-50
2.2
Contents
UNIPUMP
Description
Page
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . .
UNIPUMP
Product Selection . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNIPAK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AUTOVAR 300 Automatic Power Factor Correction
Capacitor Systems . . . . . . . . . . . . . . . . . . . . . . .
AUTOVAR 600 Automatic Power Factor
Correction Capacitor Systems . . . . . . . . . . . . . .
AUTOVAR FilterLV Automatic Detuned Filter . . .
Transient-Free Static Switching Power Factor
Correction Units . . . . . . . . . . . . . . . . . . . . . . . . .
HCU2 Harmonic Correction Unit . . . . . . . . . . . . . .
V3-T2-49
V3-T2-52
V3-T2-53
V3-T2-54
2
2
2
2
V3-T2-63
V3-T2-67
V3-T2-74
V3-T2-81
V3-T2-83
2
2
2
2
2
UNIPUMP
Product Description
Non-fused capacitors for
outdoor irrigation and oil field
installations.
Application Description
Outdoor irrigation and oil
and gas field pumping.
Terminals: Insulated
finger-safe terminals rated
for 3 kVAC withstand
Design: Self-healing
metallized high crystalline
polypropylene with ramp
metallization film. Total
losses less than 0.45 watt
per kvar. (Dielectric losses
less than 0.2 watt per kvar)
Ramp metallization:
Provides thicker film at
higher current density
areas, allowing for reduced
internal losses, lower
operating temperatures
and longer life expectancy.
Also prevents chain
reaction breakdown by
limiting propagation of
film vaporization
Pressure sensitive
interrupter: Built-in, threephase pop-up interrupter
design. UL recognized.
Removes capacitor from
line before internal
pressure can cause case
rupture. Bulged capacitor
cell top provides easy
visual indication of
interrupter operation
Ceramic discharge
resistors: Reduce residual
voltage to less than 50 volts
within one minute of
de-energization. Selected
for 20-year nominal life.
Exceeds NEC requirements
Capacitor operating
temperature: -40 F
(40 C) to +115 F
(+46 C)
Case: Weatherproof
aluminum housing
Warranty: The longest
in the industryfive full
years of warranty on
capacitor cells
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-51
2.2
2
2
Product Selection
UNIPUMP
UNIPUMP
Rated
Current
Case
Size
Cable
Size
Shipping Weight
in Lb (kg)
Catalog
Number
4.8
AA
14
10.0 (4.5)
223JMR
2.5
6.0
AA
14
10.0 (4.5)
2X23JMR
7.2
AA
14
10.0 (4.5)
323JMR
9.6
AA
14
11.0 (5.0)
423JMR
12.0
BB
12
11.0 (5.0)
523JMR
14.4
BB
12
15.0 (6.8)
623JMR
7.5
18.0
BB
12
15.0 (6.8)
7X23JMR
2.4
AA
14
10.4 (4.7)
243JMR
2.5
3.0
AA
14
10.4 (4.7)
2X43JMR
3.6
AA
14
10.4 (4.7)
343JMR
4.8
AA
14
10.4 (4.7)
443JMR
6.0
AA
14
10.4 (4.7)
543JMR
7.2
AA
14
10.6 (4.8)
643JMR
7.5
9.0
AA
14
10.6 (4.8)
7X43JMR
10
12.0
AA
14
10.8 (4.9)
1043JMR
12.5
15.0
BB
12
15.0 (6.8)
12X43JMR
15
18.0
BB
12
15.0 (6.8)
1543JMR
17.5
21.0
BB
15.8 (7.2)
17X43JMR
20
24.0
BB
16.8 (7.6)
2043JMR
25
30.0
BB
16.8 (7.6)
2543JMR
4.9
AA
14
10.8 (4.9)
563JMR
7.5
7.4
AA
14
10.8 (4.9)
7X63JMR
10
9.8
AA
14
10.8 (4.9)
1063JMR
12.5
12.3
BB
12
15.0 (6.8)
12X63JMR
15
14.7
BB
12
15.8 (7.2)
1563JMR
17.5
17.2
BB
16.8 (7.6)
17X63JMR
20
19.6
BB
16.8 (7.6)
2063JMR
kvar
240 Vac
480 Vac
600 Vac
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-52
2.2
Dimensions
1.84
(46.7)
Size Code
AA
11.00 (279.4)
14.20 (360.7)
12.60 (320.0)
13.20 (335.3)
BB
14.00 (355.6)
17.10 (434.3)
15.50 (393.7)
16.10 (408.9)
2
2
2
1.75
(44.5)
2
2
2
2
2
2
1.45
(36.8)
0.75
0.50
(12.7) (19.1)
0.44
(11.2)
1.50
(38.1)
5.15
(130.8)
1.55
(39.4)
2
2
0.07
(1.8)
2.56
(65.0)
1.98
(50.3)
2
2
2
2
2
5.00
(127.0)
1.75
(44.5)
2
2
2
2
2
2
V3-T2-53
2.2
2
Contents
UNIPAK
Description
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . .
UNIPUMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNIPAK
Features, Benefits and Functions . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . .
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
AUTOVAR 300 Automatic Power Factor Correction
Capacitor Systems . . . . . . . . . . . . . . . . . . . . . . .
AUTOVAR 600 Automatic Power Factor
Correction Capacitor Systems . . . . . . . . . . . . . .
AUTOVAR FilterLV Automatic Detuned Filter. . .
Transient-Free Static Switching Power Factor
Correction Units . . . . . . . . . . . . . . . . . . . . . . . . .
HCU2 Harmonic Correction Unit. . . . . . . . . . . . . .
2
2
2
2
2
2
2
2
2
UNIPAK
Product Description
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Two-year warranty on
capacitor cells (units with
standard-duty cells)
Five-year warranty on
capacitor cells (units with
heavy-duty cells)
Indoor/outdoor service
Short lead-times
Application Description
UNIPAK Low Voltage Fixed
Detuned Filters
Two-enclosure design
isolates capacitors from
high-temperature operating
reactors and allows for
flexible installation
2
2
V3-T2-54
Page
V3-T2-49
V3-T2-51
V3-T2-55
V3-T2-55
V3-T2-56
V3-T2-60
V3-T2-61
V3-T2-63
V3-T2-67
V3-T2-74
V3-T2-81
V3-T2-83
Elevated floor-mounting
feet allow access for easy
maintenance
Cover: L shaped
gasketed cover with
multiple fasteners provides
front opening for ease of
installation and service
UNIPAK operating
temperature: 40 F to
+115 F (40 C to +46 C)
UNIPAK storage
temperature: 40 F to
+131 F (40 C to +55 C)
Pressure-sensitive
interrupter: All units have
built-in UL recognized
pressure-sensitive
interrupter, and thermally
or mechanically activated
disconnecting link removes
capacitor from the supply
before dangerous pressure
buildup or excessive fault
current occurs. Bulged
capacitor cell top provides
easy visual indication of
interrupter operation
Standard fusing:
2.2
2
2
2
2
2
2
2
2
Options:
Non-fused units
available, selected sizes
Heavy-duty capacitor
cells, selected sizes
2
2
2
Enclosures: Standard
NEMA 1 enclosures have
durable baked powder coat
finish
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-55
2.2
Product Selection
UNIPAK
kvar
Rated
Current
(Amperes)
Enclosure
Shipping
Weight in
Lb (kg)
Catalog
Number
2.4
A1
18 (8)
123PMURF
1.5
3.6
A1
18 (8)
1X23PMURF
4.8
A1
19 (9)
223PMURF
2.5
A1
19 (9)
2X23PMURF
7.2
A1
19 (9)
323PMURF
9.6
A1
20 (9)
423PMURF
12
A2
29 (13)
523PMURF
14.4
A2
29 (13)
623PMURF
7.5
18
A2
30 (14)
7X23PMURF
19.2
A2
31 (14)
823PMURF
10
24
A2
31 (14)
1023PMURF
12.5
30
A2
32 (14)
12X23PMURF
15
36
A2
33 (15)
1523PMURF
17.5
42
B1
44 (20)
17X23PMURF
20
48
B1
45 (20)
2023PMURF
22.5
54
B1
46 (21)
22X23PMURF
25
60
B1
46 (21)
2523PMURF
30
72
B1
47 (21)
3023PMURF
32.5
78
C1
47 (22)
32X23PMURF
35
84
C1
48 (22)
3523PMURF
37.5
90
C1
60 (27)
37X23PMURF
40
96
C1
64 (29)
4023PMURF
42.5
102
C1
65 (30)
42X23PMURF
45
108
C1
66 (30)
4523PMURF
50
120
C1
68 (31)
5023PMURF
60
144
C1
69 (31)
6023PMURF
70
168
C2
99 (45)
7023PMURF
75
180
C2
100 (46)
7523PMURF
80
192
C2
101 (46)
8023PMURF
90
216
C2
103 (47)
9023PMURF
100
240
D1
104 (47)
10023PMURF
120
288
D1
133 (60)
12023PMURF
140
336
E1
137 (62)
14023PMURF
150
360
E1
140 (64)
15023PMURF
160
384
E1
175 (80)
16023PMURF
180
432
E1
182 (83)
18023PMURF
200
480
E1
189 (86)
20023PMURF
Notes
Multiply the 240 Vac kvar rating by 0.75 to calculate the kvar value at 208 Vac.
Fused with blown-fuse indication available standard. Non-fused and no lights also availableplease consult the factory.
Other ratings available, consult factory.
For dimensional information, refer to Page V3-T2-61.
Part Numbers:
PMURFthree fuses + three lights
PMURNnon-fused
2
2
2
2
V3-T2-56
kvar
Rated
Current
(Amperes)
1X43PMURF
18 (8)
243PMURF
7.5
A1
18 (8)
2X43PMURF
10
9.8
A1
19 (9)
343PMURF
12.5
12.3
4.8
A1
19 (9)
443PMURF
15
14.7
A1
19 (9)
543PMURF
17.5
17.2
kvar
Rated
Current
(Amperes)
1.5
2.2
Enclosure
Shipping
Weight in
Lb (kg)
Catalog
Number
1.8
A1
17 (8)
2.4
A1
2.5
3.6
4
5
Enclosure
Shipping
Weight in
Lb (kg)
Catalog
Number
4.9
A1
19 (9)
563PMURF
7.4
A1
19 (9)
7X63PMURF
A1
20 (9)
1063PMURF
A1
20 (9)
12X63PMURF
A2
29 (13)
1563PMURF
A2
29 (13)
17X63PMURF
7.2
A1
19 (9)
643PMURF
20
19.6
A2
30 (14)
2063PMURF
7.5
A1
20 (9)
7X43PMURF
22.5
22.1
B1
44 (20)
22X63PMURF
9.6
A1
20 (9)
843PMURF
25
24.5
B1
31 (14)
2563PMURF
10.8
A1
20 (9)
943PMURF
27.5
27.0
B1
44 (20)
27X63PMURF
10
12
A1
20 (9)
1043PMURF
30
29.4
B1
45 (20)
3063PMURF
12.5
15
A2
29 (13)
12X43PMURF
32.5
31.9
B1
45 (20)
32X63PMURF
15
18
A2
29 (13)
1543PMURF
35
34.3
B1
46 (21)
3563PMURF
17.5
21
A2
30 (14)
17X43PMURF
37.5
36.8
B1
46 (21)
37X63PMURF
20
24
A2
31 (14)
2043PMURF
40
39.2
B1
47 (21)
4063PMURF
22.5
27
B1
44 (20)
22X43PMURF
42.5
41.7
B1
47 (22)
42X63PMURF
25
30
A2
32 (15)
2543PMURF
45
44.1
B1
48 (22)
4563PMURF
27.5
33
B1
44 (20)
27X43PMURF
50
49.0
B1
48 (22)
5063PMURF
30
36
B1
44 (20)
3043PMURF
55
53.9
C1
64 (29)
5563PMURF
32.5
39
B1
45 (20)
32X43PMURF
60
58.8
C1
64 (29)
6063PMURF
35
42
B1
45 (20)
3543PMURF
65
63.7
C1
65 (30)
6563PMURF
37.5
45
B1
46 (21)
37X43PMURF
70
68.6
C1
65 (30)
7063PMURF
40
48
B1
46 (21)
4043PMURF
75
73.5
C1
66 (30)
7563PMURF
42.5
51
B1
47 (21)
42X43PMURF
80
78.4
C1
68 (31)
8063PMURF
45
54
B1
47 (22)
4543PMURF
85
83.3
C1
68 (31)
8563PMURF
50
60
B1
48 (22)
5043PMURF
90
88.2
C1
69 (31)
9063PMURF
55
66
C1
48 (22)
5543PMURF
100
98.0
C1
69 (31)
10063PMURF
60
72
C1
48 (22)
6043PMURF
120
117.6
C2
99 (45)
12063PMURF
65
78
C1
64 (29)
6543PMURF
125
122.5
C2
100 (46)
12563PMURF
70
84
C1
65 (30)
7043PMURF
140
137.2
C2
101 (46)
14063PMURF
75
90
C1
65 (30)
7543PMURF
150
147.0
C2
103 (47)
15063PMURF
80
96
C1
66 (30)
8043PMURF
160
156.8
D1
135 (61)
16063PMURF
85
102
C1
68 (31)
8543PMURF
180
176.4
D1
137 (62)
18063PMURF
90
108
C1
68 (31)
9043PMURF
200
196.0
D1
140 (64)
20063PMURF
100
120
C1
69 (31)
10043PMURF
225
220.5
D1
143 (65)
22563PMURF
120
144
C2
69 (31)
12043PMURF
250
245.0
E1
170 (77)
25063PMURF
125
150
C2
99 (45)
12543PMURF
300
294.0
E1
175 (80)
30063PMURF
140
168
C2
100 (46)
14043PMURF
350
343.0
E1
182 (83)
35063PMURF
150
180
C2
101 (46)
15043PMURF
400
392.0
E1
189 (86)
40063PMURF
160
192
D1
103 (47)
16043PMURF
Notes
Fused with blown-fuse indication available standard.
Non-fused and no lights also availableplease consult the factory.
Other ratings available, consult factory.
For dimensional information, refer to Page V3-T2-61.
Part Number
PMURFthree fuses + three lights
PMURNnon-fused
180
216
D1
104 (47)
18043PMURF
200
240
D1
137 (62)
20043PMURF
225
270
D1
140 (64)
22543PMURF
250
300
E1
170 (77)
25043PMURF
300
360
E1
175 (80)
30043PMURF
350
420
E1
182 (83)
35043PMURF
400
480
E1
189 (86)
40043PMURF
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-57
2.2
2
2
Harmonic Cells
kvar
Rated
Current
(Amperes)
Case
Size
Shipping
Weight in
Lb (kg)
Catalog
Number
240 V
15
36
B1
38.4 (17)
1523HURF
25
60
B1
38.4 (17)
2523HURF
30
72
C1
55.2 (25)
3023HURF
50
120
C1
57.6 (26)
5023HURF
60
144
C2
100.8 (46)
6023HURF
75
180
C2
104.4 (47)
7523HURF
100
240
D1
136.8 (62)
10023HURF
125
300
E1
189.6 (86)
12523HURF
15
18
B1
25.2 (11)
1543HURF
25
30
B1
37.2 (17)
2543HURF
30
36
B1
38.4 (17)
3043HURF
50
60
C1
39.6 (18)
5043HURF
60
72
C1
52.8 (24)
6043HURF
75
90
C2
55.2 (25)
7543HURF
100
120
C2
57.6 (26)
10043HURF
125
150
D1
100.8 (46)
12543HURF
150
180
D1
104.4 (47)
15043HURF
200
240
E1
136.8 (62)
20043HURF
250
300
E1
186.0 (84)
25043HURF
15
14.7
B1
37.2 (17)
1563HURF
25
24.5
B1
38.4 (17)
2563HURF
30
29.4
B1
39.6 (18)
3063HURF
50
49
C1
55.2 (25)
5063HURF
60
58.8
C1
57.6 (26)
6063HURF
75
73.5
C2
100.8 (46)
7563HURF
100
98
C2
104.4 (47)
10063HURF
125
122.5
D1
136.8 (62)
12563HURF
150
147
D1
136.8 (62)
15063HURF
200
196
E1
186.0 (84)
20063HURF
250
245
E1
189.6 (86)
25063HURF
480 V
600 V
Notes
Fused with blown-fuse indication standard.
Other ratings available, consult factory.
2
2
2
2
2
2
2
V3-T2-58
2.2
2
2
Capacitor
Enclosure
Size
Shipping
Weight
in Lb (kg)
Reactor
Enclosure
Case Size
Reactor
Shipping Weight
in Lb (kg)
Combined
Shipping Weight
in Lb (kg)
Catalog
Number
15
36
B1
48.4 (22.0)
90.0 (40.9)
138.4 (62.8)
15232HMURFY
25
60
B1
48.4 (22.0)
105.0 (47.7)
153.4 (69.6)
25232HMURFY
30
72
C1
65.2 (29.6)
110.0 (49.9)
175.2 (79.5)
30232HMURFY
50
120
C1
67.6 (30.7)
130.0 (59.0)
197.6 (89.7)
50232HMURFY
60
144
C2
110.8 (50.3)
160.0 (72.6)
270.8 (122.9)
60232HMURFY
75
180
C2
114.4 (51.9)
185.0 (84.0)
299.4 (135.9)
75232HMURFY
100
240
D1
146.8 (66.6)
240.0 (109.0)
386.8 (175.6)
100232HMURFY
125
300
E1
199.6 (90.6)
280.0 (127.1)
479.6 (217.7)
125232HMURFY
150
360
E1
220.0 (99.9)
280.0 (127.1)
500.0 (227.0)
150232HMURFY
15
18
B1
35.2 (16.0)
90.0 (40.9)
125.2 (56.8)
15432HMURFY
25
30
B1
47.2 (21.4)
105.0 (47.7)
152.2 (69.1)
25432HMURFY
30
36
B1
48.4 (22.0)
110.0 (49.9)
158.4 (71.9)
30432HMURFY
50
60
C1
49.6 (22.5)
130.0 (59.0)
179.6 (81.5)
50432HMURFY
60
72
C1
62.8 (28.5)
160.0 (72.6)
222.8 (101.2)
60432HMURFY
75
90
C2
65.2 (29.6)
185.0 (84.0)
250.2 (113.6)
75432HMURFY
100
120
C2
67.6 (30.7)
240.0 (109.0)
307.6 (139.7)
100432HMURFY
125
150
D1
110.8 (50.3)
280.0 (127.1)
390.8 (177.4)
125432HMURFY
150
180
D1
114.4 (51.9)
280.0 (127.1)
394.4 (179.1)
150432HMURFY
200
240
E1
146.8 (66.6)
330.0 (149.8)
476.8 (216.5)
200432HMURFY
250
300
E1
196.0 (89.0)
570.0 (258.8)
766.0 (347.8)
250432HMURFY
14.7
B1
47.2 (21.4)
90.0 (40.9)
137.2 (62.3)
15632HMURFY
kvar
2
2
240 V
480 V
600 V
15
25
24.5
B1
48.4 (22.0)
90.0 (47.7)
153.4 (69.6)
25632HMURFY
30
29.4
B1
49.6 (22.5)
105.0 (49.9)
159.6 (72.5)
30632HMURFY
50
49
C1
65.2 (29.6)
110.0 (59.0)
195.2 (88.6)
50632HMURFY
60
58.8
C1
67.6 (30.7)
130.0 (72.6)
227.6 (103.3)
60632HMURFY
75
73.5
C2
110.8 (50.3)
160.0 (84.0)
295.8 (134.3)
75632HMURFY
100
98
C2
114.4 (51.9)
185.0 (109.0)
354.4 (160.9)
100632HMURFY
150
147
D1
146.8 (66.6)
280.0 (127.1)
426.8 (193.8)
150632HMURFY
200
196
E1
196.0 (89.0)
330.0 (149.8)
526.0 (238.8)
200632HMURFY
250
245
E1
199.6 (90.6)
570.0 (258.8)
769.6 (349.4)
250632HMURFY
Notes
Other ratings available, consult factory.
Fused with blown-fuse indication standard.
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-59
2.2
2
2
Wiring Diagram
Filter Schematic with Wiring Interconnects
Power Lines from Disconnect
2
2
Lugs
Fuses
2
Reactor Enclosure
2
2
Lugs
Lugs
Capacitor Enclosure
2
2
Note
1 Refer to NEC.
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-60
2.2
Dimensions
Reactor Cabinet
Case Size
Height
Width
Depth
24.75 (628.7)
20.00 (508.0)
18.13 (460.5)
25.00 (635.0)
24.25 (616.0)
20.25 (514.4)
31.00 (787.4)
25.00 (635.0)
32.75 (831.9)
2
2
2
2
2
Case B1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
UNIPAK Enclosures
Case Size
X1
X2
X3
A1
5.30 (134.6)
8.50 (215.9)
3.50 (88.9)
3.80 (96.5)
10.60 (269.2)
17.30 (439.4)
6.80 (172.7)
2.00 (50.8)
N/A
N/A
7.70 (195.6)
7.20 (182.9)
A2
6.00 (152.4)
8.50 (215.9)
5.60 (142.2)
4.50 (114.3)
13.30 (337.8)
22.30 (566.4)
6.80 (172.7)
2.30 (58.4)
N/A
N/A
7.70 (195.6)
7.20 (182.9)
B1
11.10 (281.9)
10.10 (256.5)
5.80 (147.3)
9.60 (243.8)
15.70 (398.8)
25.30 (642.6)
8.50 (215.9)
4.10 (104.1)
4.50 (114.3)
N/A
9.30 (236.2)
8.80 (223.5)
Legend:
A = Total depth
B = Total width
D = Height of removable front cover
E = Depth of feet
F = Height of middle mounting hole in wall bracket
H = Total height
L = Width without feet and brackets
X = Depth between front and rear mounting holes in inches
Y = Width between floor mounting holes
Z = Width between wall bracket mounting holes
2
2
2
2
2
2
2
2
V3-T2-61
2.2
2
2
Case D1, E1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
UNIPAK Enclosures
Case
Size
X1
X2
X3
C1
10.60 (269.2)
12.10 (307.3)
7.10 (180.3)
9.10 (231.1)
16.20 (411.5)
26.30 (668.0)
10.40 (264.2)
3.40 (86.4)
1.10 (27.9)
3.60 (91.4)
11.30 (287.0)
10.70 (271.8)
C2
12.00 (304.8)
19.30 (490.2)
16.90 (429.3)
9.50 (241.3)
16.30 (414.0)
36.00 (914.4)
17.70 (449.6)
3.00 (76.2)
1.50 (38.1)
3.80 (96.5)
18.30 (464.8)
18.00 (457.2)
D1
16.80 (426.7)
19.30 (490.2)
16.90 (429.3)
14.60 (370.8)
N/A
36.00 (914.4)
17.70 (449.6)
5.10 (129.5)
2.40 (61.0)
5.00 (127.0)
18.30 (464.8)
N/A
E1
22.30 (566.4)
24.40 (619.8)
16.80 (426.7)
19.50 (495.3)
N/A
36.00 (914.4)
22.70 (576.6)
6.50 (165.1)
4.40 (111.8)
5.00 (127.0)
22.40 (569.0)
N/A
Legend:
A = Total depth
B = Total width
D = Height of removable front cover
E = Depth of feet
F = Height of middle mounting hole in wall bracket
H = Total height
L = Width without feet and brackets
X = Depth between front and rear mounting holes in inches
Y = Width between floor mounting holes
Z = Width between wall bracket mounting holes
2
2
2
2
2
V3-T2-62
2.2
Contents
AUTOVAR 300
Description
Page
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . .
UNIPUMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNIPAK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AUTOVAR 300 Automatic Power Factor Correction
Capacitor Systems
Product Selection . . . . . . . . . . . . . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
AUTOVAR 600 Automatic Power Factor
Correction Capacitor Systems . . . . . . . . . . . . . .
AUTOVAR FilterLV Automatic Detuned Filter . . .
Transient-Free Static Switching Power Factor
Correction Units . . . . . . . . . . . . . . . . . . . . . . . . .
HCU2 Harmonic Correction Unit . . . . . . . . . . . . . .
V3-T2-49
V3-T2-51
V3-T2-54
V3-T2-65
V3-T2-64
V3-T2-66
V3-T2-67
V3-T2-74
V3-T2-81
V3-T2-83
2
2
2
2
2
2
2
2
2
2
Product Description
Automatically switched
power factor correction
systems for low voltage
applications.
Application Description
AUTOVAR 300 is an ideal
capacitor bank to automatically
regulate power factor where
floor space is limited and
expansion of the facilitys
electrical load is not
expected.
Features
Configuration
Cabinet: Wallmounting 12
gauge steel with ANSI 61
gray, NEMA 1 (gasketed)
Fusing: 200,000 A
interrupting capacity
provided on all three
phases of each stage.
Blade-type fuses mounted
on insulator stand-offs with
cleared-fuse indicating
lights
Cleared-fuse lights:
Cleared-fuse neon
indicating lights for each
phase and stage located on
the door
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-63
2.2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Controller
Visual indication of
incorrect CT polarity
Visual indication of
insufficient kvar to reach
target power factor
Optional communications
capable controller (RS-485/
Modbus)
Standard metering
capability:
Voltage
Frequency
Individual harmonic
voltage distortion (odd
orders up to the 19th
harmonic)
Undervoltage or
overvoltage
Undercurrent or
overcurrent
Harmonic overload
Faulty step/stages
Overtemperature alarm
Contactor
UL/CSA listed
and recognized
Entire cabinet assembly is
UL 508A and CSA C22.2
No. 190 Listed
Capacitors are UL 810
recognized
Contactor is UL/CSA
recognized and IEC 6b
rated
Options
Hand-Off-Auto switches
Communications capable
controller
Support and Service
2
2
2
2
2
V3-T2-64
2.2
Product Selection
kvar
Step x
kvar
Base
Shipping Weight
in Lb (kg) 1
Rated Current
Amperes
Options
Option
Code
Description
Catalog
Number
240 V
25
5x5
60
217 (98.5)
25MCSR2313
50
5 x 10
120
255 (115.8)
50MCSR2313
2
2
75
5 x 15
180
260 (118.0)
75MCSR2313
100
5 x 20
240
270 (122.6)
100MCSR231
125
5 x 25
300
292 (132.6)
125MCSR231
480 V
Breaker
AUTOVAR Rated Size
Current Amperes (Amperes) 3
Breaker
Interrupting
Rating (kA)
Breaker
Weight
in Lb (kg)
Standard
Wire Lug Size
50
5 x 10
60
200 (90.8)
50MCSR4313
75
5 x 15
90
210 (95.3)
75MCSR4313
kvar
100
5 x 20
120
210 (95.3)
100MCSR4313
240 V
125
5 x 25
150
240 (109.0)
125MCSR4313
25
60
125
100
10 (4.5)
(1) #3350
150
5 x 30
180
240 (109.0)
150MCSR4313
50
120
250
100
10 (4.5)
(1) #3350
175
5 x 35
210
260 (118.0)
175MCSR431
75
180
250
100
10 (4.5)
(1) #3350
100
240
400
100
10 (4.5)
(2) #3/0250
125
300
600
100
25 (11.4)
(2) #3/0350
50
60
125
65
10 (4.5)
(1) #3350
75
90
125
65
10 (4.5)
(1) #3350
200
5 x 40
241
270 (122.6)
200MCSR431
225
5 x 45
270
290 (131.7)
225MCSR431
250
5 x 50
300
292 (132.6)
250MCSR431
600 V
480 V
2
2
50
5 x 10
48
200 (90.8)
50MCSR6313
100
120
250
65
10 (4.5)
(1) #3350
75
5 x 15
72
210 (95.3)
75MCSR6313
125
150
250
65
10 (4.5)
(1) #3350
100
5 x 20
96
210 (95.3)
100MCSR6313
150
180
250
65
10 (4.5)
(1) #3350
125
5 x 25
120
240 (109.0)
125MCSR6313
175
210
400
65
10 (4.5)
(2) #3/0250
150
5 x 30
144
240 (109.0)
150MCSR6313
200
240
400
65
10 (4.5)
(2) #3/0250
225
270
400
65
10 (4.5)
(2) #3/0250
250
300
600
65
25 (11.4)
(2) #3/0350
48
125
35
10 (4.5)
(1) #3350
175
5 x 35
168
260 (118.0)
175MCSR631
200
5 x 40
192
270 (122.6)
200MCSR631
225
5 x 45
216
290 (131.7)
225MCSR631
250
5 x 50
240
292 (132.6)
250MCSR631
Spare Fuses
kvar Rating/Bank
600 V
50
75
72
125
35
10 (4.5)
(1) #3350
100
96
250
35
10 (4.5)
(1) #3350
125
120
250
35
10 (4.5)
(1) #3350
150
144
250
35
10 (4.5)
(1) #3350
175
168
250
35
10 (4.5)
(1) #3350
200
192
400
35
10 (4.5)
(2) #3/0350
240 V
480 V
600 V
Amperes
Eaton Fuse
Part Number
10
10
30
SP030217-0029J
225
216
400
35
10 (4.5)
(2) #3/0350
15
20
50
SP030217-0037D
250
240
400
35
10 (4.5)
(2) #3/0350
10
20
60
SP030217-0037E
25
2530
80
SP030217-0037G
15
30
40
100
SP030217-0037J
20
40
50
125
SP030217-0037K
25
50
150
SP030217-0037L
Renewal Parts
Description
Catalog Number
SP039010-0035U
Replacement contactor, 72 A
SP039010-0014B
Replacement contactor, 32 A
SP039010-0014C
Notes
1 To calculate AUTOVAR 300 weight:
1. Obtain base unit weight from table above.
2. Add option weights as necessary:
A = 1 lb
C = 1 lb
H = 5 lb
W = 10 lb
M = 50 lb enclosure weight adder plus circuit breaker weight (see circuit breaker table)
S = Consult Eatons Technical Resource Center (TRC) at 1-800-809-2772, choose option
#4, then option #2
3
4
Heavy-duty cells, 50 Hz units, and other ratings available, please consult factory. A minimum
of one CT is required per AUTOVAR unit. kvar output is voltage and frequency dependent.
60 Hz units are shown. For other voltages and frequencies, consult Eaton Technical Resource
Center (TRC) at 1-800-809-2772, choose option #4, then option #2.
Manual control is always available through controller menu system, even if the H option is
not selected.
Breakers are sized at a minimum of 135% of the unit rated Amperes per the NEC.
See equipment drawings for actual lug sizes.
V3-T2-65
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2.2
2
Dimensions
Approximate Dimensions in Inches (mm)
Enclosure J
Front View
Side View
0.63
(16.0)
On/Off
Switch
2
2
Power
Factor
Controller
2
2
Keylock
Handle
Blown
Fuse
Lights
2
2
29.88
(759.0)
36.00
(914.4)
0.63
(16.0)
2
2
2
Description
Height A
J1
36.00 (914.4)
14.00 (355.6)
J2
60.00 (1524.0)
14.00 (355.6)
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-66
Depth B
2.2
Contents
AUTOVAR 600
Description
Page
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . .
UNIPUMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNIPAK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AUTOVAR 300 Automatic Power Factor Correction
Capacitor Systems . . . . . . . . . . . . . . . . . . . . . . .
AUTOVAR 600 Automatic Power Factor
Correction Capacitor Systems
Standards and Certifications . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
AUTOVAR FilterLV Automatic Detuned Filter . . .
Transient-Free Static Switching Power Factor
Correction Units . . . . . . . . . . . . . . . . . . . . . . . . .
HCU2 Harmonic Correction Unit . . . . . . . . . . . . . .
V3-T2-49
V3-T2-51
V3-T2-54
V3-T2-63
V3-T2-68
V3-T2-69
V3-T2-73
V3-T2-74
V3-T2-81
V3-T2-83
2
2
2
2
2
2
2
2
2
2
2
Features
Programmable to
automatically add/subtract
capacitor stages to
maintain preset target
power factor
Three-phase capacitor cell
construction
Five-year warranty of cells
against manufacturing
defects
Cool operating, 100%
copper wound, thermalprotected reactors are
sized up to 150% of rated
capacitor current (AUTOVAR
detuned filter only)
Application Description
Service entrance or
substation power factor
correction installations
requiring precise
maintenance of target
power factor (AUTOVAR 600)
Service entrance or
substation power factor
correction installations
requiring precise
maintenance of target
power factor in threephase, nonlinear, high
harmonic environments
(AUTOVAR detuned filter)
Typically connected at main
low voltage switchgear
Configuration
Fusing: UL recognized,
200,000 A interrupting
capacity provided on all
three phases of each
stage. Blade-type fuses
mounted on insulator
stand-offs
Cleared-fuse indicating
lights: LEDs located doormounted and neon at
individual fuses to facilitate
tracing of cleared fuses
Push-to-test: Allows
testing of door-mounted
LED cleared fuse indicating
lights
AutoLocate: When door is
open and bus is energized,
fuse circuit automatically
checks for cleared fuses. If
a fuse has cleared, the light
at the fuse turns on for
easy troubleshooting
Door interlock: Door
interlock automatically
turns off control circuit
when engaged. Power
continues to be provided to
the unit until disconnect is
open
Exhaust fans: Two side
louver fans per cabinet
provide cooling and reduce
operator exposure to
discharge. Replaceable
dust filtering provided.
Dust filters can be replaced
without opening cabinet
Ease of expansion:
Capacitor stage nests are
self-contained and can be
added in the field. Two
bolts mount the nest in the
field. Control wire plugs
connect to factory
standard wire harness on
the left side of the cabinet
Ease of replacement:
Cells can be easily
replaced individually by
removing the mounting
bolt and lifting out of the
nest without removal of
any other components
Thermal sensing: Built-in
thermal sensing, alarming,
and protection feature
allows the unit to operate
in optimal temperature
while alerting the user of
ambient temperature
exceeding the nominal
operating range. Stages
will be automatically
switched off if temperature
exceeds the maximum
specified temperature
Temperature range: The
operating temperature
range is 20C to +46C,
and the storage
temperature range is
40C to +55C. For
optimal equipment life, the
temperature should not
exceed 35C annual
average, and the
environment should not
exceed Pollution Degree 2
as defined in UL 61010-1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-67
2.2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Controller
Visual indication of
incorrect CT polarity
Visual indication of
insufficient kvar to reach
target power factor
Optional communications
capable controller (RS-485/
Modbus)
Voltage
Frequency
Individual harmonic
voltage distortion (odd
orders up to the 19th
harmonic)
Undervoltage or
overvoltage
Undercurrent or
overcurrent
Harmonic overload
Faulty step/stages
Overtemperature alarm
Contactor
Detuning: Standard
reactor designs are
detuned to the 4.2nd
harmonic and recommended
to protect capacitors
against harmonic resonance.
Detuning to the 4.7th
harmonic is available as an
option. The harmonic
spectrum should be
evaluated for applications
involving reactors detuned
to the 4.7th harmonic to
ensure optimal equipment
life, specifically when used
in conjunction with sixpulse motor drives
Windings: 80C
temperature rise design
100% copper windings for
minimal losses
Thermal overload
protection: Each reactor
includes three normally
closed, auto reset
thermostats that open at
180C. When thermostats
engage, the contactor
opens
Insulation: 220C
insulation system
Warranty: One-year
replacement of reactors
Additional Features
Optional molded-case main
circuit breaker
Control wiringstandard
NEC color-coded modular
bundles with quick
disconnect feature for ease
of troubleshooting or ease
of expendability. UL type
MTW/AWM, CSA TEW
105C copper wire is
standard.
2
2
2
2
V3-T2-68
2.2
Product Selection
Option
Code
Description
Remote alarm relay terminal blockrelay terminal block for a remote alarm to
indicate controller alarm status
Integrated main breaker with high interrupting rating (see breaker table
for more information), includes 100 kA busbar bracing
M1
N1
T1
T2
2
2
2
2
Notes
1 Manual control is always available through menu controller on system, even if the H option is
not selected.
2 Not available on NEMA 3R units (W option).
3 Only available on AUTOVAR 600 with heavy-duty cells and AUTOVAR detuned filters
using L + L, L + KK, and KK + KK enclosures.
4 Tuning to the 4.2nd harmonic is the preferred option. Other tunings available. Contact Eatons
Technical Resource Center (TRC) power factor application engineers at 1-800-809-2772,
choose option #4, then option #2.
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-69
2.2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
kvar 1
240 Vac
75
100
125
150
200
250
300
350
400
480 Vac
100
150
200
250
300
350
400
450
500
550
600
660
700
720
800
900
1000
1100
1200
600 Vac
100
150
200
250
300
350
400
450
500
550
600
660
700
720
800
900
1000
1100
1200
Step x
kvar
Rated
Current
Amperes
Base
Shipping
Weight
in Lb (kg)
Base
Catalog
Number
3 x 25
4 x 25
5 x 25
6 x 25
8 x 25
10 x 25
12 x 25
7 x 50
8 x 50
180
240
300
361
481
600
720
844
965
644 (292.4)
692 (314.2)
740 (336.0)
788 (357.8)
884 (401.3)
944 (428.6)
1022 (464.0)
1616 (734.0)
1704 (774.0)
75TPCSR231
100TPCSR231
125TPCSR231
150TPCSR231
200TPCSR231
250TPCSR231
300TPCSR231
350TPCSR231
400TPCSR231
2 x 50
3 x 50
4 x 50
5 x 50
6 x 50
7 x 50
8 x 50
9 x 50
10 x 50
11 x 50
12 x 50
11 x 60
7 x 100
12 x 60
8 x 100
9 x 100
10 x 100
11 x 100
12 x 100
120
180
240
300
360
420
480
540
600
660
720
792
840
864
960
1080
1200
1320
1440
588 (266.7)
632 (287.0)
676 (306.9)
720 (326.9)
764 (346.9)
808 (366.8)
852 (386.8)
896 (406.8)
944 (428.6)
984 (446.7)
1022 (464.0)
1010 (458.5)
1616 (734.0)
1050 (476.7)
1704 (774.0)
1792 (814.0)
1888 (857.0)
1966 (893.0)
2044 (928.0)
100TPCSR431
150TPCSR431
200TPCSR431
250TPCSR431
300TPCSR431
350TPCSR431
400TPCSR431
450TPCSR431
500TPCSR431
550TPCSR431
600TPCSR431
660TPCSR431
700TPCSR431
720TPCSR431
800TPCSR431
900TPCSR431
1000TPCSR431
1100TPCSR431
1200TPCSR431
2 x 50
3 x 50
4 x 50
5 x 50
6 x 50
7 x 50
8 x 50
9 x 50
10 x 50
11 x 60
12 x 50
11 x 60
7 x 100
12 x 60
8 x 100
9 x 100
10 x 100
11 x 100
12 x 100
46
144
192
240
288
336
384
432
480
528
576
634
672
692
768
864
960
1056
1152
588 (266.7)
632 (287.0)
676 (306.9)
720 (326.9)
764 (346.9)
808 (366.8)
852 (386.8)
896 (406.8)
944 (428.6)
984 (446.7)
1022 (464.0)
1010 (458.5)
1616 (734.0)
1050 (476.7)
1704 (774.0)
1792 (814.0)
1888 (857.0)
1966 (893.0)
2044 (928.0)
100TPCSR631
150TPCSR631
200TPCSR631
250TPCSR631
300TPCSR631
350TPCSR631
400TPCSR631
450TPCSR631
500TPCSR631
550TPCSR631
600TPCSR631
660TPCSR631
700TPCSR631
720TPCSR631
800TPCSR631
900TPCSR631
1000TPCSR631
1100TPCSR631
1200TPCSR631
Step x
kvar
3 x 25
4 x 25
5 x 25
6 x 25
8 x 25
10 x 25
12 x 25
7 x 50
8 x 50
L
L
L
L
L
L
L
KK
KK
L
L
L
L
L
L
L
KK
C/F
2 x 50
3 x 50
4 x 50
5 x 50
6 x 50
7 x 50
8 x 50
9 x 50
10 x 50
11 x 50
12 x 50
11 x 60
14 x 50
12 x 60
8 x 100
9 x 100
10 x 100
11 x 100
12 x 100
L
L
L
L
L
L
L
L
L
L
L
L
KK
L
KK
KK
KK
KK
KK
L
L
L
L
L
L
L
L
L
L
L
L
KK
L
C/F
C/F
C/F
C/F
C/F
2 x 50
3 x 50
4 x 50
5 x 50
6 x 50
7 x 50
8 x 50
9 x 50
10 x 50
11 x 50
12 x 50
11 x 60
14 x 50
12 x 60
8 x 100
9 x 100
10 x 100
11 x 100
12 x 100
L
L
L
L
L
L
L
L
L
L
L
L
KK
L
KK
KK
KK
KK
KK
L
L
L
L
L
L
L
L
L
L
L
L
KK
L
KK
KK
C/F
C/F
C/F
Notes
1 Other ratings available. Please consult factory. kvar output is voltage and frequency
dependent. 60 Hz units are shown. For other voltages and frequencies, consult Eaton
Technical Resource Center (TRC) at 1-800-809-2772, choose option #4, then option #2.
2 Enclosure sizing for units with integrated surge protection or bottom entry can vary
and may not be available on all kvar sizes. Contact Eatons Technical Resource Center at
1-800-809-2772, choose option #4, then option #2.
2
2
2
kvar
240 Vac
75
100
125
150
200
250
300
350
400
480 Vac
100
150
200
250
300
350
400
450
500
550
600
700
800
900
1000
1100
1200
600 Vac
100
150
200
250
300
350
400
450
500
550
600
700
800
900
1000
1100
1200
Step x
kvar
Rated
Current
Amperes
Base
Shipping
Weight in
Lb (kg)
Base
Catalog
Number
3 x 25
4 x 25
5 x 25
6 x 25
8 x 25
10 x 25
12 x 25
7 x 50
8 x 50
180
240
300
361
481
601
720
844
965
659 (298.9)
712 (323.0)
765 (347.0)
818 (371.0)
924 (419.1)
994 (450.9)
1082 (490.8)
1686 (764.8)
1784 (809.2)
75TPHSR231
100TPHSR231
125TPHSR231
150TPHSR231
200TPHSR231
250TPHSR231
300TPHSR231
350TPHSR231
400TPHSR231
2 x 50
3 x 50
4 x 50
5 x 50
6 x 50
7 x 50
8 x 50
9 x 50
10 x 50
11 x 50
12 x 50
14 x 50
8 x 100
9 x 100
10 x 100
11 x 100
12 x 100
120
180
240
300
360
420
480
540
600
660
720
792
462
1083
1203
1323
1443
617 (279.9)
677 (307.1)
736 (333.8)
795 (360.6)
854 (387.4)
913 (414.1)
972 (440.9)
1031 (467.7)
1094 (496.2)
1149 (521.2)
1202 (545.2)
1826 (828.3)
1944 (881.8)
2062 (935.3)
2198 (997.0)
2296 (1041.4)
2404 (1090.4)
100TPHSR431
150TPHSR431
200TPHSR431
250TPHSR431
300TPHSR431
350TPHSR431
400TPHSR431
450TPHSR431
500TPHSR431
550TPHSR431
600TPHSR431
700TPHSR431
800TPHSR431
900TPHSR431
1000TPHSR431
1100TPHSR431
1200TPHSR431
2 x 50
3 x 50
4 x 50
5 x 50
6 x 50
7 x 50
8 x 50
9 x 50
10 x 50
11 x 60
12 x 50
7 x 100
8 x 100
9 x 100
10 x 100
11 x 100
12 x 100
96
144
192
240
288
336
384
432
480
529
576
672
768
864
962
1058
1155
617 (279.9)
677 (307.1)
736 (333.8)
795 (360.6)
854 (387.4)
913 (414.1)
972 (440.9)
1031 (467.7)
1094 (496.2)
1149 (521.2)
1202 (545.2)
1826 (828.3)
1944 (881.8)
2062 (935.3)
2198 (997.0)
2296 (1041.4)
2404 (1090.4)
100TPHSR631
150TPHSR631
200TPHSR631
250TPHSR631
300TPHSR631
350TPHSR631
400TPHSR631
450TPHSR631
500TPHSR631
550TPHSR631
600TPHSR631
700TPHSR631
800TPHSR631
900TPHSR631
1000TPHSR631
1100TPHSR631
1200TPHSR631
2.2
kvar
240 V
75
100
125
150
200
250
300
350
400
480 V
100
150
200
250
300
350
400
450
500
550
600
700
800
900
1000
1100
1200
600 V
100
150
200
250
300
350
400
450
500
550
600
700
800
900
1000
1100
1200
Step x
kvar
NEMA 1,
without Main
Breaker,
No Suffix
NEMA 1,
with Main
Breaker,
M Suffix
NEMA 3R,
without Main
Breaker,
W Suffix
NEMA 3R,
with Main
Breaker,
MW Suffix
3 x 25
4 x 25
5 x 25
6 x 25
8 x 25
10 x 25
12 x 25
7 x 50
8 x 50
L
L
L
L
L
L
L
L
KK
L
L
L
L
L
L
L
KK
C/F
L
L
L
L
L
L
L
KK
KK
L
L
L
L
L
L
L
KK
C/F
2 x 50
3 x 50
4 x 50
5 x 50
6 x 50
7 x 50
8 x 50
9 x 50
10 x 50
11 x 50
12 x 50
14 x 50
8 x 100
9 x 100
10 x 100
11 x 100
12 x 100
L
L
L
L
L
L
L
L
L
L
L
KK
KK
KK
KK
KK
KK
L
L
L
L
L
L
L
L
L
L
L
KK
C/F
C/F
C/F
C/F
C/F
L
L
L
L
L
L
L
L
L
L
L
KK
KK
KK
KK
KK
KK
L
L
L
L
L
L
L
L
L
L
L
KK
C/F
C/F
C/F
C/F
C/F
2 x 50
3 x 50
4 x 50
5 x 50
6 x 50
7 x 50
8 x 50
9 x 50
10 x 50
11 x 50
12 x 50
14 x 50
8 x 100
9 x 100
10 x 100
11 x 100
12 x 100
L
L
L
L
L
L
L
L
L
L
L
KK
KK
KK
KK
KK
KK
L
L
L
L
L
L
L
L
L
L
L
KK
KK
KK
C/F
C/F
C/F
L
L
L
L
L
L
L
L
L
L
L
KK
KK
KK
KK
KK
KK
L
L
L
L
L
L
L
L
L
L
L
KK
KK
KK
C/F
C/F
C/F
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Notes
1 Other ratings available. Please consult factory. kvar output is voltage and frequency
dependent. 60 Hz units are shown. For other voltages and frequencies, consult Eaton
Technical Resource Center (TRC) at 1-800-809-2772, choose option #4, then option #2.
2 Enclosure sizing for units with integrated surge protection or bottom entry can vary
and may not be available on all kvar sizes. Contact Eatons Technical Resource Center at
1-800-809-2772, choose option #4, then option #2.
C/F = Consult factory
2
2
2
2
2
V3-T2-71
2.2
2
2
kvar 1
Step x
kvar
Rated
Current
Amperes
Base
Shipping
Weight
in Lb (kg)
Base
Catalog Number
Step x
kvar
NEMA 1
without Main
Breaker,
No Suffix
NEMA 1
with Main
Breaker,
M Suffix
NEMA 3R
without Main
Breaker,
W Suffix
NEMA 3R
with Main
Breaker,
MW Suffix
240 Vac
150
6 x 25
361
1830 (830.8)
150THFSR232Y
240 V
200
8 x 25
481
2222 (1008.8
200THFSR232Y
150
6 x 25
L+L3
L+L3
L+L3
L+L3
250
10 x 25
601
2525 (1146.4)
250THFSR232Y
200
8 x 25
L+L3
L+L3
L+L3
L+L3
300
12 x 25
720
2830 (1284.8)
300THFSR232Y
250
10 x 25
L+L3
L+L3
L+L3
L+L3
350
7 x 50
844
3090 (1401.6)
350THFSR231Y
300
12 x 25
L+L3
KK
L+L3
KK
400
8 x 50
965
3560 (1614.8)
400THFSR232Y
350
7 x 50
KK
L + KK 3
L + KK 3
KK
480 Vac
400
8 x 50
L + KK 3
C/F
L + KK 3
C/F
100
2 x 50
120
1105 (501.2)
100THFSR431Y
480 V
150
3 x 50
180
1242 (564.6)
150THFSR431Y
100
2 x 50
L+L3
L+L3
200
4 x 50
240
1438 (652.9)
200THFSR431Y
150
3 x 50
L+L3
L+L3
250
5 x 50
300
1634 (741.8)
250THFSR431Y
200
4 x 50
L+L3
L+L3
300
6 x 50
360
1830 (830.8)
300THFSR432Y
L+L
L+L3
350
7 x 50
420
2026 (919.8)
350THFSR432Y
300
6 x 50
L+L
L+L
L+L3
400
8 x 50
480
2222 (1008.8)
400THFSR432Y
350
7 x 50
L+L3
L+L3
L+L3
L+L3
450
9 x 50
540
2371 (1076.4)
450THFSR432Y
400
8 x 50
L+L3
L+L3
L+L3
L+L3
500
10 x 50
600
2525 (1146.4)
500THFSR432Y
450
9 x 50
L+L3
L+L3
L+L3
L+L3
550
11 x 50
660
2750 (1248.5)
550THFSR432Y
500
10 x 50
L+L3
L+L3
L+L3
L+L3
12 x 50
720
2830 (1284.8)
600THFSR432Y
550
11 x 50
L+L
600
700
7 x 100
792
3090 (1401.6)
700THFSR431Y
600
12 x 50
L+L3
800
8 x 100
962
3560 (1614.8)
800THFSR432Y
700
7 x 100
900
9 x 100
1083
3900 (1769.0)
900THFSR432Y
800
1000
10 x 100
1203
4240 (1923.2)
1000THFSR432Y
1100
11 x 100
1323
4500 (2041.2)
1100THFSR432Y
2
2
kvar
250
5 x 50
L
3
L+L
L+L
KK
L+L
L + KK 3
KK
L+L3
L + KK 3
KK
KK
L + KK 3
L + KK 3
8 x 100
L + KK 3
C/F
L + KK 3
C/F
900
9 x 100
KK + KK 3
C/F
KK + KK 3
C/F
1000
10 x 100
KK + KK 3
C/F
KK + KK 3
C/F
1100
11 x 100
KK + KK 3
C/F
KK + KK 3
C/F
600 Vac
100
2 x 50
96
1105 (501.2)
100THFSR631Y
600 V
150
3 x 50
144
1242 (564.6)
150THFSR631Y
100
2 x 50
L+L3
L+L3
200
4 x 50
192
1438 (652.9)
200THFSR631Y
150
3 x 50
L+L3
L+L3
250
5 x 50
240
1634 (741.8)
250THFSR631Y
200
4 x 50
L+L3
L+L3
300
6 x 50
288
1830 (830.8)
300THFSR632Y
L+L
L+L3
350
7 x 50
336
2026 (919.8)
350THFSR632Y
300
6 x 50
L+L
L+L
L+L3
400
8 x 50
384
2222 (1008.8)
400THFSR632Y
350
7 x 50
L+L3
L+L3
L+L3
L+L3
450
9 x 50
432
2371 (1076.4)
450THFSR632Y
400
8 x 50
L+L3
L+L3
L+L3
L+L3
500
10 x 50
480
2525 (1146.4)
500THFSR632Y
450
9 x 50
L+L3
L+L3
L+L3
L+L3
550
11 x 50
529
2750 (1248.5)
550THFSR632Y
500
10 x 50
L+L3
L+L3
L+L3
L+L3
600
12 x 50
576
2830 (1284.8)
600THFSR632Y
11 x 50
L+L
700
7 x 100
672
3090 (1401.6)
700THFSR631Y
600
12 x 50
L+L
800
8 x 100
768
3560 (1614.8)
800THFSR632Y
700
7 x 100
KK
900
9 x 100
864
3900 (1769.0)
900THFSR632Y
800
8 x 100
L + KK 3
1000
10 x 100
962
4240 (1923.2)
1000THFSR632Y
900
9 x 100
1100
11 x 100
1058
4500 (2041.2)
1100THFSR632Y
1000
1100
250
550
5 x 50
L
3
L+L
L+L
L+L
L + KK 3
KK
L+L
L + KK 3
KK
L + KK 3
L + KK 3
L + KK 3
L + KK 3
L + KK 3
KK + KK 3
KK + KK 3
KK + KK 3
KK + KK 3
10 x 100
KK + KK 3
C/F
KK + KK 3
C/F
11 x 100
KK + KK 3
C/F
KK + KK 3
C/F
KK
Notes
1 kvar output is voltage and frequency dependent. 60 Hz units are shown. For other voltages
and frequencies, consult Eaton Technical Resource Center (TRC) at 1-800-809-2772, choose
option #4, then option #2.
2 Enclosure sizing for units with integrated surge protection or bottom entry can vary
and may not be available on all kvar sizes. Contact Eatons Technical Resource Center at
1-800-809-2772, choose option #4, then option #2.
3 Dual enclosure design requires customer installation of factory supplied interconnecting
wires.
2
2
2
2
2
V3-T2-72
2.2
Dimensions
Power
Conductor
Lugs
POWER
FACTOR
CORRECTION
69B1007G01
1
2
3
Option W NEMA 3R
Drip Shield
2
2
Exhaust
BLR-ACX
Option M
Molded-Case
Circuit Breaker
esc
PHASE A
PHASE B
PHASE C
DANGER
HIGH VOLTAGE
CAUTION
DISCONNECT
Ground
Lug
BEFORE SERVICING
78.00
(1981.2)
Copper
Busbar
2
A
A
38.50
(977.9)
41.30 (1049.0)
Mounting Holes
0.438-Inch Dia. Typ.
25.00
(635.0) 16.00
(406.4)
25.00
(635.0)
Legend
1. Controller
2. On/Off Switch
3. Cleared Fuse Indicating Lights
Notes:
1. 6-Inch Minimum Clearance Each Side
2. 45-Inch Front Clearance or per Local Code
Air Filter
Section A-A
Power
Conductor
Lugs
POWER
FACTOR
CORRECTION
69B1007G01
1
2
3
BLR-ACX
esc
PHASE A
PHASE B
2
2
Exhaust
Ground
Lug
PHASE C
Option M
Molded-Case
Circuit Breaker
78.00
(1981.2)
Copper
Busbar
2
2
A
25.00
(635.0)
77.64 (1972.0)
80.40 (2042.1)
25.00 16.00
(635.0) (406.4)
Air Filter
Air Filter
Mounting Holes
0.438-Inch Dia. Typ.
Legend
1. Controller
2. On/Off Switch
3. Cleared Fuse Indicating Lights
2
2
Notes:
1. 6-Inch Minimum Clearance Each Side
2. 45-Inch Front Clearance or per Local Code
Section A-A
V3-T2-73
2.2
2
Contents
AUTOVAR Filter
Description
Page
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . .
UNIPUMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNIPAK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AUTOVAR 300 Automatic Power Factor Correction
Capacitor Systems . . . . . . . . . . . . . . . . . . . . . . .
AUTOVAR 600 Automatic Power Factor
Correction Capacitor Systems . . . . . . . . . . . . . .
AUTOVAR FilterLV Automatic Detuned Filter
Standards and Certifications . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transient-Free Static Switching Power Factor
Correction Units . . . . . . . . . . . . . . . . . . . . . . . . .
HCU2 Harmonic Correction Unit. . . . . . . . . . . . . .
2
2
2
2
2
2
V3-T2-49
V3-T2-51
V3-T2-54
V3-T2-63
V3-T2-67
V3-T2-75
V3-T2-76
V3-T2-78
V3-T2-81
V3-T2-83
2
2
2
Product Description
2
2
2
2
2
2
2
2
Application Description
2
2
2
2
2
2
2
Programmable to
automatically add/subtract
capacitor stages to
maintain preset target
power factor
Three-phase capacitor cell
construction
Five-year warranty of cells
against manufacturing
defects
Cool operating, 100%
copper wound, thermalprotected reactors are
sized up to 150% of rated
capacitor current (AUTOVAR
detuned filter only)
Service entrance or
substation power factor
correction installations
requiring precise
maintenance of target
power factor (AUTOVAR 600)
Service entrance or
substation power factor
correction installations
requiring precise
maintenance of target
power factor in threephase, nonlinear, high
harmonic environments
(AUTOVAR detuned filter)
Typically connected at main
low voltage switchgear
2
2
V3-T2-74
Features
Configuration
Fusing: UL recognized,
200,000 A interrupting
capacity provided on all
three phases of each
stage. Blade-type fuses
mounted on insulator
stand-offs
Cleared-fuse indicating
lights: LEDs located doormounted and neon at
individual fuses to facilitate
tracing of cleared fuses
Push-to-test: Allows
testing of door-mounted
LED cleared fuse indicating
lights
AutoLocate: When door is
open and bus is energized,
fuse circuit automatically
checks for cleared fuses. If
a fuse has cleared, the light
at the fuse turns on for
easy troubleshooting
Door interlock: Door
interlock automatically
turns off control circuit
when engaged. Power
continues to be provided to
the unit until disconnect is
open
Exhaust fans: Two side
louver fans per cabinet
provide cooling and reduce
operator exposure to
discharge. Replaceable
dust filtering provided.
Dust filters can be replaced
without opening cabinet
Ease of expansion:
Capacitor stage nests are
self-contained and can be
added in the field. Two
bolts mount the nest in the
field. Control wire plugs
connect to factory
standard wire harness on
the left side of the cabinet
Ease of replacement:
Cells can be easily
replaced individually by
removing the mounting
bolt and lifting out of the
nest without removal of
any other components
Thermal sensing: Built-in
thermal sensing, alarming,
and protection feature
allows the unit to operate
in optimal temperature
while alerting the user of
ambient temperature
exceeding the nominal
operating range. Stages
will be automatically
switched off if temperature
exceeds the maximum
specified temperature
Temperature range: The
operating temperature
range is 20C to +46C,
and the storage
temperature range is
40C to +55C. For
optimal equipment life, the
temperature should not
exceed 35C annual
average, and the
environment should not
exceed Pollution Degree 2
as defined in UL 61010-1
Controller
Visual indication of
incorrect CT polarity
Visual indication of
insufficient kvar to reach
target power factor
Optional communications
capable controller (RS-485/
Modbus)
Voltage
Frequency
Individual harmonic
voltage distortion (odd
orders up to the 19th
harmonic)
Undervoltage or
overvoltage
Undercurrent or
overcurrent
Harmonic overload
Faulty step/stages
Overtemperature alarm
Contactor
Detuning: Standard
reactor designs are
detuned to the 4.2nd
harmonic and recommended
to protect capacitors
against harmonic resonance.
Detuning to the 4.7th
harmonic is available as an
option. The harmonic
spectrum should be
evaluated for applications
involving reactors detuned
to the 4.7th harmonic to
ensure optimal equipment
life, specifically when used
in conjunction with sixpulse motor drives
Windings: 80C
temperature rise design
100% copper windings for
minimal losses
Thermal overload
protection: Each reactor
includes three normally
closed, auto reset
thermostats that open at
180C. When thermostats
engage, the contactor
opens
Insulation: 220C
insulation system
Warranty: One-year
replacement of reactors
Additional Features
Optional molded-case main
circuit breaker
Control wiringstandard
NEC color-coded modular
bundles with quick
disconnect feature for ease
of troubleshooting or ease
of expendability. UL type
MTW/AWM, CSA TEW
105C copper wire is
standard.
2.2
2
2
2
2
2
2
2
2
2
2
AUTOVAR FilterReactor Cabinet
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-75
2.2
Product Selection
Description
2
2
Option
Code
Remote alarm relay terminal blockrelay terminal block for a remote alarm to
indicate controller alarm status
Integrated main breaker with high interrupting rating (see breaker table
for more information), includes 100 kA busbar bracing
M1
N1
T1
T2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
W
Y
Notes
1 Manual control is always available through menu controller on system, even if the H option is
not selected.
2 Not available on NEMA 3R units (W option).
3 Only available on AUTOVAR 600 with heavy-duty cells and AUTOVAR detuned filters
using L + L, L + KK, and KK + KK enclosures.
4 Tuning to the 4.2nd harmonic is the preferred option. Other tunings available. Contact Eatons
Technical Resource Center (TRC) power factor application engineers at 1-800-809-2772,
choose option #4, then option #2.
To calculate AUTOVAR 600 or AUTOVAR detuned filter weight:
Obtain base unit weight from table on Page V3-T2-77 (as appropriate).
Add option weights as necessary:
A = 1 lb (0.5 kg)
B = 10 lb (4.5 kg)
C = 1 lb (0.5 kg)
H = 10 lb (4.5 kg)
M = Circuit breaker weight (see circuit breaker table)
M1 = 10 lb (4.5 kg) hardware weight adder plus circuit breaker
weight (see circuit breaker table)
N1 = 10 lb (4.5 kg)
T1 = 5 lb (2.3 kg)
T2 = 10 lb (4.5 kg)
Q = 5 lb (2.3 kg)
W = 10 lb (4.5 kg) per door
Y = 0 lb (0 kg)
2
2
2
2
2
2
2
2
2
V3-T2-76
2.2
Step x
kvar
Rated
Current
Amperes
Base
Shipping
Weight
in Lb (kg)
Base
Catalog Number
6 x 25
361
1830 (830.8)
150THFSR232Y
240 V
200
8 x 25
481
2222 (1008.8
200THFSR232Y
150
250
10 x 25
601
2525 (1146.4)
250THFSR232Y
200
300
12 x 25
720
2830 (1284.8)
300THFSR232Y
250
350
7 x 50
844
3090 (1401.6)
350THFSR231Y
300
400
8 x 50
965
3560 (1614.8)
400THFSR232Y
350
kvar 1
kvar
240 Vac
150
Enclosure Size 2
480 Vac
NEMA 1
without Main
Breaker,
No Suffix
NEMA 1
with Main
Breaker,
M Suffix
NEMA 3R
without Main
Breaker,
W Suffix
NEMA 3R
with Main
Breaker,
MW Suffix
6 x 25
L+L3
L+L3
L+L3
L+L3
8 x 25
L+L3
L+L3
L+L3
L+L3
10 x 25
L+L3
L+L3
L+L3
L+L3
12 x 25
L+L3
KK
L+L3
KK
7 x 50
KK
L + KK 3
L + KK 3
KK
Step x
kvar
L+L3
L+L3
L+L3
L+L3
L+L
L+L3
L+L3
L+L3
L+L3
L+L3
L+L3
L+L3
L+L3
L+L3
L+L3
L+L3
8 x 50
L+L3
L+L3
L+L3
L+L3
9 x 50
L+L3
L+L3
L+L3
L+L3
10 x 50
L+L3
L+L3
L+L3
L+L3
11 x 50
L+L
600
12 x 50
700
7 x 100
900THFSR432Y
800
1000THFSR432Y
900
1100THFSR432Y
1000
L + KK
100
2 x 50
150
3 x 50
120
1105 (501.2)
100THFSR431Y
480 V
150
3 x 50
180
1242 (564.6)
150THFSR431Y
200
4 x 50
240
1438 (652.9)
200THFSR431Y
250
5 x 50
300
1634 (741.8)
250THFSR431Y
200
4 x 50
300
6 x 50
360
1830 (830.8)
300THFSR432Y
250
5 x 50
350
7 x 50
420
2026 (919.8)
350THFSR432Y
300
6 x 50
400
8 x 50
480
2222 (1008.8)
400THFSR432Y
350
7 x 50
450
9 x 50
540
2371 (1076.4)
450THFSR432Y
400
500
10 x 50
600
2525 (1146.4)
500THFSR432Y
450
550
11 x 50
660
2750 (1248.5)
550THFSR432Y
500
600
12 x 50
720
2830 (1284.8)
600THFSR432Y
550
700
7 x 100
792
3090 (1401.6)
700THFSR431Y
800
8 x 100
962
3560 (1614.8)
800THFSR432Y
900
9 x 100
1083
3900 (1769.0)
1000
10 x 100
1203
4240 (1923.2)
1100
11 x 100
1323
4500 (2041.2)
600 Vac
1100
C/F
L+L
2
2
2
2
2
KK
L+L
L + KK 3
L+L3
KK
L+L3
L + KK 3
KK
KK
L + KK 3
L + KK 3
8 x 100
L + KK 3
C/F
L + KK 3
C/F
9 x 100
KK + KK 3
C/F
KK + KK 3
C/F
10 x 100
KK + KK 3
C/F
KK + KK 3
C/F
11 x 100
KK + KK
C/F
KK + KK 3
C/F
2
2
2 x 50
96
1105 (501.2)
100THFSR631Y
600 V
150
3 x 50
144
1242 (564.6)
150THFSR631Y
100
2 x 50
L+L3
L+L3
200
4 x 50
192
1438 (652.9)
200THFSR631Y
150
3 x 50
L+L3
L+L3
250
5 x 50
240
1634 (741.8)
250THFSR631Y
200
4 x 50
L+L3
L+L3
300
6 x 50
288
1830 (830.8)
300THFSR632Y
250
5 x 50
L+L3
L+L3
L+L3
350
7 x 50
336
2026 (919.8)
350THFSR632Y
300
6 x 50
L+L3
L+L3
L+L3
L+L3
400
8 x 50
384
2222 (1008.8)
400THFSR632Y
350
7 x 50
L+L3
L+L3
L+L3
L+L3
450
9 x 50
432
2371 (1076.4)
450THFSR632Y
400
8 x 50
L+L3
L+L3
L+L3
L+L3
500
10 x 50
480
2525 (1146.4)
500THFSR632Y
450
9 x 50
L+L3
L+L3
L+L3
L+L3
550
11 x 50
529
2750 (1248.5)
550THFSR632Y
500
10 x 50
L+L
600
12 x 50
576
2830 (1284.8)
600THFSR632Y
550
11 x 50
L+L3
KK
L+L3
L + KK 3
700
7 x 100
672
3090 (1401.6)
700THFSR631Y
600
12 x 50
L+L3
KK
L+L3
L + KK 3
800
8 x 100
768
3560 (1614.8)
800THFSR632Y
700
7 x 100
KK
KK
L + KK 3
L + KK 3
900
9 x 100
864
3900 (1769.0)
900THFSR632Y
800
8 x 100
L + KK 3
L + KK 3
L + KK 3
L + KK 3
1000
10 x 100
962
4240 (1923.2)
1000THFSR632Y
900
9 x 100
KK + KK 3
KK + KK 3
KK + KK 3
KK + KK 3
1100
11 x 100
1058
4500 (2041.2)
1100THFSR632Y
1000
10 x 100
KK + KK 3
C/F
KK + KK 3
C/F
11 x 100
C/F
KK + KK 3
C/F
KK + KK
L+L
L+L
2
2
2
100
1100
L + KK
8 x 50
2 x 50
C/F
400
100
L+L
Notes
1 kvar output is voltage and frequency dependent. 60 Hz units are shown. For other voltages
and frequencies, consult Eaton Technical Resource Center (TRC) at 1-800-809-2772, choose
option #4, then option #2.
2 Enclosure sizing for units with integrated surge protection or bottom entry can vary
and may not be available on all kvar sizes. Contact Eatons Technical Resource Center at
1-800-809-2772, choose option #4, then option #2.
3 Dual enclosure design requires customer installation of factory supplied interconnecting
wires.
2
2
2
2
2
2
2
2
2
2
2
2
2
Volume 3Power Distribution and Control Assemblies CA08100004EAugust 2016 www.eaton.com
V3-T2-77
2.2
2
2
2
Dimensions
Approximate Dimensions in Inches (mm)
AUTOVAR L (Single Door) Enclosure
Standard Customer Conduit
Entry in This Area
2
2
2
2
Option W NEMA 3R
Drip Shield
Power
Conductor
Lugs
POWER
FACTOR
CORRECTION
69B1007G01
1
2
3
Exhaust
BLR-ACX
Option M
Molded-Case
Circuit Breaker
esc
PHASE A
PHASE B
PHASE C
DANGER
HIGH VOLTAGE
CAUTION
DISCONNECT
Ground
Lug
BEFORE SERVICING
78.00
(1981.2)
Copper
Busbar
2
2
38.50
(977.9)
2
2
2
41.30 (1049.0)
Mounting Holes
0.438-Inch Dia. Typ.
25.00
(635.0) 16.00
(406.4)
25.00
(635.0)
Legend
1. Controller
2. On/Off Switch
3. Cleared Fuse Indicating Lights
Air Filter
Notes:
1. 6-Inch Minimum Clearance Each Side
2. 45-Inch Front Clearance or per Local Code
2
2
Section A-A
Power
Conductor
Lugs
POWER
FACTOR
CORRECTION
69B1007G01
1
2
3
BLR-ACX
esc
PHASE A
PHASE B
Exhaust
Ground
Lug
PHASE C
Option M
Molded-Case
Circuit Breaker
78.00
(1981.2)
Copper
Busbar
2
2
2
77.64 (1972.0)
2
2
25.00
(635.0)
80.40 (2042.1)
25.00 16.00
(635.0) (406.4)
Air Filter
Air Filter
Mounting Holes
0.438-Inch Dia. Typ.
Legend
1. Controller
2. On/Off Switch
3. Cleared Fuse Indicating Lights
Notes:
1. 6-Inch Minimum Clearance Each Side
2. 45-Inch Front Clearance or per Local Code
Section A-A
2
V3-T2-78
2.2
POWER
FACTOR
CORRECTION
69B1007G01
1
2
3
Option M
Molded-Case
Circuit Breaker
BLR-CX
PHASE A
PHASE B
Power
Conductor
Lugs
Exhaust
PHASE C
DANGER
DANGER
HIGH VOLTAGE
HIGH VOLTAGE
CAUTION
CAUTION
DISCONNECT
DISCONNECT
BEFORE SERVICING
BEFORE SERVICING
Capacitor
Enclosure
Ground
Lug
78.00
(1981.2)
Reactor
Enclosure
Copper
Busbar
2
2
Dust/Air
Filter Tray
Typ.
38.50 (977.9)
25.00
16.00
(635.0)
(406.4)
Air Filter
Mounting Holes
0.438-Inch Dia. Typ.
Air Filter
Section A-A
Legend
1. Controller
2. On/Off Switch
3. Cleared Fuse Indicating Lights
41.26 (1048.0)
Notes:
1. 6-Inch Minimum Clearance Each Side
2. 45-Inch Front Clearance or per Local Code
3. 12-Inch Minimum Separation Between Enclosures
Section B-B
BLR-ACX
esc
PHASE B
Exhaust
DANGER
HIGH VOLTAGE
CAUTION
78.00
(1981.2)
BEFORE SERVICING
Capacitor
Enclosure
Reactor
Enclosure
2
2
PHASE C
DISCONNECT
2
2
Power
Conductor
Ground
Lugs
Lug
PHASE A
2
2
2
3
2
2
Copper
Busbar
2
A
B
77.64 (1972.0)
Air Filter
Section A-A
38.50 (977.9)
Dust/Air
Filter Tray Typ.
Legend
1. Controller
2. On/Off Switch
3. Cleared Fuse Indicating Lights
2
2
80.40 (2042.1)
Air Filter
Air Filter
Section B-B
Mounting Holes
0.438-Inch Dia. Typ.
Notes:
1. 6-Inch Minimum Clearance
Each Side
2. 45-Inch Front Clearance or per
Local Code
3. 12-Inch Minimum Separation
Between Enclosures
2
2
2
V3-T2-79
2.2
AUTOVAR KK + KK Enclosures
Option W NEMA 3R
Drip Shield
Exhaust
2
2
2
3
POWER
FACTOR
CORRECTION
Power
Conductor
Lugs
POWER
FACTOR
CORRECTION
69B1007G01
69B1007G01
BLR-ACX
esc
PHASE A
PHASE B
PHASE C
Ground
Lug
78.00
(1981.2)
Capacitor
Enclosure
2
2
B
Dust/Air
Filter Tray
Factory Supplied 12-Inch Conduit and
Power/Control Cables. Interconnect in Field
by Customer/Installing Contractor Required
2
2
77.64 (1972.1)
2
2
Copper
Busbar
Reactor
Enclosure
80.40 (2042.1)
25.00 16.00
(635.0)(406.4)
Air Filter
Air Filter
Section A-A
Legend
1. Controller
2. On/Off Switch
3. Cleared Fuse Indicating Lights
2
2
Air Filter
Air Filter
Mounting
Holes
0.438-Inch
Dia. Typ.
Section B-B
Notes:
1. 6-Inch Minimum Clearance Each Side
2. 45-Inch Front Clearance or per Local Code
3. 12-Inch Minimum Separation Between Enclosures
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-80
2.2
Contents
Description
Page
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . .
UNIPUMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNIPAK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AUTOVAR 300 Automatic Power Factor Correction
Capacitor Systems . . . . . . . . . . . . . . . . . . . . . . .
AUTOVAR 600 Automatic Power Factor
Correction Capacitor Systems . . . . . . . . . . . . . .
AUTOVAR FilterLV Automatic Detuned Filter . . .
Transient-Free Static Switching Power Factor
Correction Units
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
HCU2 Harmonic Correction Unit . . . . . . . . . . . . . .
V3-T2-49
V3-T2-51
V3-T2-54
2
2
2
V3-T2-63
V3-T2-67
V3-T2-74
V3-T2-82
V3-T2-83
2
2
2
2
2
2
Application Description
The FTA and FTE units
employ a fast or real-time
response, and include the
ability to switch larger steps
without creating significant
line noise. These relatively
maintenance-free units reside
in a smaller footprint and are
ideal for use in applications
such as flicker control, large
motor starting, bus voltage
stabilization, fault ridethrough solutions, power
factor correction and
many more.
Motor starting
On-site generation support
Spot welding
Wind turbines
Other dynamic loads
EMCEN50081-2,
EN50082-2, EN55011,
EN61000-4-2/3/4/5,
ENV50204, ENV50141
CE Mark73/23/EEC am.
93/68, 98/37/EC art. 4(2)
SafetyEN61010-1,
EN60439-1, EN60204
UL 508
CSA
2
2
2
2
2
2
2
2
Startup and
Commissioning by
factory trained personnel
is required for proper
operation and warranty
of this system
2
2
2
2
2
2
2
2
2
2
2
V3-T2-81
2.2
Product Selection
2
2
2
2
2
2
2
2
Type of industry
Type of application
Project objectives
2
2
2
2
2
2
Hz
(Yes/No)
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-82
2.2
Contents
Description
Page
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . .
UNIPUMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNIPAK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AUTOVAR 300 Automatic Power Factor Correction
Capacitor Systems . . . . . . . . . . . . . . . . . . . . . . .
AUTOVAR 600 Automatic Power Factor
Correction Capacitor Systems . . . . . . . . . . . . . .
AUTOVAR FilterLV Automatic Detuned Filter . . .
Transient-Free Static Switching Power Factor
Correction Units . . . . . . . . . . . . . . . . . . . . . . . . .
HCU2 Harmonic Correction Unit
Catalog Number Selection . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
V3-T2-49
V3-T2-51
V3-T2-54
2
2
2
V3-T2-63
V3-T2-67
V3-T2-74
V3-T2-81
V3-T2-84
V3-T2-84
2
2
2
2
2
Application Description
Features, Benefits
and Functions
Fast-acting harmonic
correction
NEMA 1, NEMA 2, NEMA
12, IP31, IP54 enclosures,
and chassis mount
versions available
60, 120, 200 and 300 A
units available (ampere
rating given at 380480 V)
Touchscreen human
machine interface (HMI)
Communications
connectivity
Designed for use in
environmentally controlled
conditions
Can be sized to meet
specific levels of harmonic
correction, providing
compliance with IEEE 519
recommended levels
Engineered to prevent
overloading
Scalable design can be
expanded without
impacting performance
Broad spectrum of
cancellation for robust
protection (2nd to 51st
harmonic)
Helps improve power
factor to maximize
efficiency
Reduced footprint:
Wall-mounted 480 V
NEMA 1 units are
available in 60, 120, 200
and 300 A ratings
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
UL/CSA approved
2
Volume 3Power Distribution and Control Assemblies CA08100004EAugust 2016 www.eaton.com
V3-T2-83
2.2
HCU2 060 D5 N2
2
2
Equipment Type
HCU2 = Harmonic correction unit
2
2
2
2
2
2
2
Ampere Rating
380480 V only
060 = 60 A
120 = 120 A
200 = 200 A
300 = 300 A
600 V only
047 = 47 A
094 = 94 A
157 = 157 A
235 = 235 A
690 V only
040 = 40 A
080 = 80 A
133 = 133 A
200 = 200 A
Voltage
D5 = 380480 V D7 = 3690 V
D6 = 600 V
IP00
N1
N2
N12
IP31
IP54
=
=
=
=
=
=
Enclosure Type
Chassis mount
NEMA 1 wall mount
NEMA 2 floor mount
NEMA 12 floor mount
IP31 floor mount
IP54 floor mount
Typical Uncorrected 6-Pulse Rectifier (Before) Current + HCU2 Injection Current = Corrected (After) Current
2
2
2
2
2
2
2
Recommended Placement
2
2
2
Source
Typical CT
Placement
Transformer
2
2
HCU
Load(s)
2
2
2
2
V3-T2-84
2.2
Description
Specification
Technical Specifications
Communications capability
Discrete input/outputs
Nominal frequency
Number of phases
3-phase
Description
2
2
Earthing (grounding) systems EMC filter ground switch for Isolated Terra, high resistance
Topology
Losses
Environmental Condition
Operating temperature
0 C to 40 C
Relative humidity
095%, noncondensing
Seismic rating
Operating altitude
2
2
CT VA loading
1.0 VA (5 A CT secondary)
Spectrum cancellation
Control basis
Harmonic attenuation
Closed loop: <3% THD(i); max. 20:1 THD(i) reduction with load
harmonic current above 50% of HCU2 rating
Open loop: <5% TDD
Requires 3% or higher inductive impedance per nonlinear load
Ambient temperature
protection
Harmonic operational
features
Reference Standards
Harmonic avoidance
Parallel operation
Master/master Master/slave
Multi-master/multi-slave
Same as Eaton HCUE for retrofits
2
2
2
2
Design
Protection (enclosure)
Standards compliance/
certification
2
2
2
Installation
Wall mount
Free-standing
Circuit protection
Parallel communications
AIC rating
(input circuit breaker)
Cable entry
25 s
2 cycles
PCBA protection
1/4 cycle
Cooling configuration
Display
Display parameters
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V3-T2-85
2.2
Model
Voltage (V)
Frequency (Hz)
Total Current
Amperes (rms)
HCU2060D5N1
380480
50/60
60
HCU2120D5N1
380480
50/60
120
HCU2200D5N1
380480
50/60
200
HCU2300D5N1
380480
50/60
300
7.1
UL/CSA
No
HCU2060D5IP00
380480
50/60
60
1.3
Chassis mount
UL/CSA
No
HCU2120D5IP00
380480
50/60
120
2.8
Chassis mount
UL/CSA
No
HCU2200D5IP00
380480
50/60
200
5.4
Chassis mount
UL/CSA
No
HCU2300D5IP00
380480
50/60
300
7.1
Chassis mount
UL/CSA
No
HCU2060D5IP31
380480
50/60
60
1.3
CE
Yes
HCU2120D5IP31
380480
50/60
120
2.8
CE
Yes
HCU2200D5IP31
380480
50/60
200
5.4
CE
Yes
HCU2300D5IP31
380480
50/60
300
7.1
CE
Yes
HCU2060D5N2
380480
50/60
60
1.3
UL/CSA
Yes
HCU2120D5N2
380480
50/60
120
2.8
UL/CSA
Yes
HCU2200D5N2
380480
50/60
200
5.4
UL/CSA
Yes
HCU2300D5N2
380480
50/60
300
7.1
UL/CSA
Yes
HCU2060D5N12
380480
50/60
60
1.3
UL/CSA
Yes
HCU2120D5N12
380480
50/60
120
2.8
UL/CSA
Yes
HCU2200D5N12
380480
50/60
200
5.4
UL/CSA
Yes
HCU2300D5N12
380480
50/60
300
7.1
UL/CSA
Yes
HCU2060D5IP54
380480
50/60
60
1.3
CE
Yes
HCU2120D5IP54
380480
50/60
120
2.8
CE
Yes
HCU2200D5IP54
380480
50/60
200
5.4
CE
Yes
HCU2300D5IP54
380480
50/60
300
7.1
CE
Yes
HCU2047D6IP31
600
50/60
47
1.8
CE
Yes
HCU2094D6IP31
600
50/60
94
3.9
CE
Yes
HCU2157D6IP31
600
50/60
157
7.2
CE
Yes
HCU2235D6IP31
600
50/60
235
9.9
CE
Yes
HCU2047D6N2
600
50/60
47
1.8
UL/CSA
Yes
HCU2094D6N2
600
50/60
94
3.9
UL/CSA
Yes
HCU2157D6N2
600
50/60
157
7.2
UL/CSA
Yes
HCU2235D6N2
600
50/60
235
9.9
UL/CSA
Yes
HCU2047D6IP54
600
50/60
47
1.8
CE
Yes
HCU2094D6IP54
600
50/60
94
3.9
CE
Yes
HCU2157D6IP54
600
50/60
157
7.2
CE
Yes
HCU2235D6IP54
600
50/60
235
9.9
CE
Yes
HCU2047D6N12
600
50/60
47
1.8
UL/CSA
Yes
HCU2094D6N12
600
50/60
94
3.9
UL/CSA
Yes
HCU2157D6N12
600
50/60
157
7.2
UL/CSA
Yes
2
2
2
2
Version
Integral
Disconnect
1.3
UL/CSA
No
2.8
UL/CSA
No
5.4
UL/CSA
No
HCU2235D6N12
600
50/60
235
9.9
UL/CSA
Yes
HCU2040D7IP31
690
50/60
40
2.1
CE
Yes
HCU2080D7IP31
690
50/60
80
4.5
CE
Yes
HCU2133D7IP31
690
50/60
133
8.2
CE
Yes
HCU2200D7IP31
690
50/60
200
11.4
CE
Yes
HCU2040D7N2
690
50/60
40
2.1
UL/CSA
Yes
HCU2080D7N2
690
50/60
80
4.5
UL/CSA
Yes
HCU2133D7N2
690
50/60
133
8.2
UL/CSA
Yes
HCU2200D7N2
690
50/60
200
11.4
UL/CSA
Yes
HCU2040D7IP54
690
50/60
40
2.1
CE
Yes
HCU2080D7IP54
690
50/60
80
4.5
CE
Yes
HCU2133D7IP54
690
50/60
133
8.2
CE
Yes
HCU2200D7IP54
690
50/60
200
11.4
CE
Yes
HCU2040D7N12
690
50/60
40
2.1
UL/CSA
Yes
HCU2080D7N12
690
50/60
80
4.5
UL/CSA
Yes
HCU2133D7N12
690
50/60
133
8.2
UL/CSA
Yes
HCU2200D7N12
690
50/60
200
11.4
UL/CSA
Yes