A. NURSERY (PRE-KINDERGARTEN)
NURSERY IS THE LEVEL OF EDUCATION BELOW KINDERGARTEN, THE ADMISSION AGE FOR WHICH
IS AT LEAST THREE (3) YEARS BUT NOT MORE THAN FOUR (4) YEARS OLD. AS STATED IN MEC ORDER
NO. 24, S. 1978 DATED JULY 26, 1978 THE FOLLOWING STANDARDS FOR THE ORGANIZATION AND
OPERATION OF NURSERY CLASSES ARE REQUIRED:
CLASS SIZE MAXIMUM OF 15 CHILDREN TO A CLASS
CLASS HOURS 2 HOURS DAILY
PHYSICAL STRUCTURE FLOOR AREA OF AT LEAST 7M X 9M IN A 500 TO 1,000 SQUARE
METERS LOT
a.
b.
c.
C. EQUIPMENT
A. PLAYGROUND AND GARDEN
PLAYGROUND APPARATUSES MUST BE INSTALLED IN THE SCHOOL GROUND (JUNGLE
GYM, SANDBOX, SLIDE, BALANCE BEAMS, SIMPLE OBSTACLES TIRES AND TUNNELS)
B. CLASSROOM EQUIPMENT AND FIXTURES
FURNITURE (TABLES, CHAIRS, SHELVES, LOCKERS AND CABINETS MUST CONFORM TO
THE STANDARDS BASED ON AN ANTHROPOMETRIC MEASUREMENT OF PRESCHOOL AGE
CHILDREN, BOTH IN STANDING AND SITTING POSITIONS.
BEDS AND/OR MATS MAY BE PROVIDED FOR REST PERIODS.
1. DESIGN GUIDELINES
THE FOLLOWING GENERAL GUIDELINES SHALL BE OBSERVED IN THE DESIGN OF SCHOOL
BUILDINGS:
A. A SCHOOL BUILDING SHALL BE DESIGNED IN ACCORDANCE WITH ITS FUNCTIONS, NEEDS OF ITS
USER, AND THE NATURE OF THE ENVIRONMENT.
B. IN VIEW OF SCARCE RESOURCES, A SCHOOL BUILDING SHALL BE CONCEIVED FOR ECONOMY IN
CONSTRUCTION, UTILIZATION AND MAINTENANCE.
C. THE DESIGN APPROACH SHALL BE STRAIGHT FORWARD, RELYING UPON SIMPLICITY OF
CONCEPT IN THE CONTEXT OF INNOVATION TO REFLECT ORDER AND DIGNITY, ENSURE FLEXIBILITY IN
ANTICIPATION OF EDUCATIONAL CHANGE, AND ACHIEVE STRUCTURAL STABILITY.
D. HUMAN DIMENSIONS, STATIC AND DYNAMIC, SPECIFICALLY WITH REFERENCE TO FILIPINO
CHILDREN AND YOUTH, SHALL BE THE BASIS FOR ESTABLISHING SCALE.
E. AESTHETIC ELEMENTS SHALL BE INTEGRAL TO THE OVERALL DESIGN AND EVEN GIVEN
CONTEMPORARY TREATMENT, SHALL DERIVE FROM HISTORICAL, TRADITIONAL OR NATIVE THEMES.
F. THE USE OF INDIGENOUS OR LOCALLY PRODUCED MATERIALS SHALL BE MAXIMIZED IN
CONJUNCTION WITH THE APPLICATION OF APPROPRIATE CONSTRUCTION TECHNOLOGY.
G. PROVISION FOR MOBILITY OF HANDICAPPED/DISABLED PERSONS SHALL BE GIVEN DUE
CONSIDERATION IN THE DESIGN AND CONSTRUCTION OF SCHOOL BUILDINGS AND OTHER FACILITIES IN
ACCORDANCE WITH BATAS PAMBANSA BILANG 344. (ACCESSIBILITY LAW).
THE FOREGOING GUIDELINES ARE INTENDED TO COMPLEMENT ACCEPTED ARCHITECTURAL AND
ENGINEERING PRINCIPLES, AND THE PROVISIONS OF THE NATIONAL BUILDING CODE OF THE PHILIPPINES,
AND OTHER RELEVANT RULES, REGULATIONS AND ORDINANCE PROMULGATED BY THE NATIONAL AND
LOCAL AGENCIES.
IN DESIGNING SCHOOL BUILDINGS, CONSIDERATION OF ERGONOMICS, ANTHROPOMETRICS,
THERMAL COMFORT, ILLUMINATION, ACOUSTICS AND COLORS, AS MENTIONED IN CHAPTER I IS VERY
SIGNIFICANT.
THE PREVAILING WINDS/BREEZES REFER TO THE DIRECTION IN WHICH THE COOLING BREEZES
BLOW. IN THE PHILIPPINES, ESPECIALLY DURING THE HOT SEASON, PREVAILING BREEZES GENERALLY
HAVE A NORTHEAST TO SOUTHWEST DIRECTION.
4. LAYOUT
THE LAYOUT OF SCHOOL BUILDING ON THE SCHOOL SITE REFERS TO THE LOCATION AND
ARRANGEMENT OF SCHOOL BUILDINGS TO ACHIEVE MAXIMUM FUNCTIONAL EFFICIENCY AND AESTHETIC
EFFECT. AS A GENERAL RULE, THE DIFFERENT SCHOOL BUILDINGS SHALL BE LAID OUT ACCORDING TO
FUNCTIONAL GROUPING. THE DISTANCES BETWEEN SCHOOL BUILDINGS SHALL BE SUCH THAT:
A. VENTILATION IS NOT OBSTRUCTED;
B. NATURAL ILLUMINATION IS NOT IMPEDED; AND
C. SOUNDS IN ONE BUILDING DO NOT CARRY INTO THE NEXT BUILDING.
D. THE SUGGESTED MINIMUM DISTANCES BETWEEN BUILDINGS ARE:
D.1 EIGHT (8) METERS BETWEEN ONE-STOREY BUILDINGS POSITIONED SIDE BY SIDE;
D.2 TEN (10) METERS BETWEEN TWO-STOREY ACADEMIC BUILDINGS POSITIONED SIDE
BY SIDE;
D.3 TEN (10) METERS BETWEEN NON-ACADEMIC BUILDINGS;
D.4 FOR A MAIN BUILDING FACING THE FRONT GATE, AT LEAST TEN (10) METERS
DISTANCE IS SUGGESTED.
D.5 GREATER DISTANCE THAN THE MINIMUM BETWEEN SCHOOL BUILDINGS IS
DESIRABLE. WIDER DISTANCE BETWEEN BUILDINGS ALLOWS FOR ADEQUATE FREE
SPACE TO BE UTILIZED FOR MANY SCHOOL-RELATED ACTIVITIES.
E. THE RECOMMENDED MINIMUM SETBACK OF A SCHOOL FROM THE STREET IS FIVE (5) METERS
TO MINIMIZE INTRUSIVE SOUNDS.
F. THE SCHOOL SITE DEVELOPMENT PLAN MUST BE CONSIDERED IN THE LAYING-OUT OF SCHOOL
BUILDINGS.
5. BUILDING PLANS
THERE ARE TWO TYPES OF PLANS FOR THE DESIGN AND SPECIFICATIONS OF PUBLIC
ELEMENTARY AND SECONDARY SCHOOL BUILDINGS.
A. STANDARD BUILDING PLAN. THIS IS USUALLY PREPARED BY THE ARCHITECTS AND
ENGINEERS OF THE DEPED AND THE DPWH AND APPROVED FOR GENERAL USE IN ALL SCHOOLS
THROUGHOUT THE COUNTRY.
B. SPECIAL BUILDING PLAN. THIS IS A PLAN DESIGNED SPECIFICALLY FOR A PARTICULAR
SCHOOL FOR A SPECIAL PURPOSE OR BECAUSE OF CERTAIN UNIQUE OR PECULIAR FEATURES OF
THE SCHOOL SITE. A SPECIAL BUILDING PLAN MAY ORIGINATE FROM THE FIELD.
C. THE ARCHITECTURAL AND STRUCTURAL PLANS SHALL BE SIGNED BY AN ARCHITECT AND CIVIL
ENGINEER RESPECTIVELY, DULY STAMPED WITH THEIR DRY SEALS ALONG WITH THEIR
REGISTRY NUMBERS, PROFESSIONAL TAX RECEIPTS, AND TAX IDENTIFICATION NUMBERS (TIN).
D. THE STRUCTURAL COMPUTATIONS SIGNED BY A REGISTERED CIVIL ENGINEER AND STAMPED
WITH HIS DRY SEAL SHALL BE SUBMITTED TOGETHER WITH THE PLAN FOR CHECKING. THE
REGISTRY NUMBER, PROFESSIONAL TAX NUMBER, AND TAX IDENTIFICATION NUMBER OF THE CIVIL
ENGINEER SHALL BE ALSO INDICATED.
E. THE PLAN SHALL BE SIGNED ALSO BY THE SCHOOL ADMINISTRATOR CONCERNED AND
RECOMMENDED BY THE SCHOOLS DIVISION SUPERINTENDENT AND THE DEPED REGIONAL
DIRECTOR (IN THE CASE OF LOCALLY DESIGNED SCHOOL BUILDING).
7. DESIGN REQUIREMENTS
THE FOLLOWING PERTINENT REQUIREMENTS PRESCRIBED IN THE NATIONAL BUILDING CODE OF
THE PHILIPPINES SHALL BE CONSIDERED IN THE DESIGN OF SCHOOL BUILDINGS:
A. WINDOWS. WINDOW OPENINGS SHALL BE EQUAL TO OR AT LEAST TEN (10) PERCENT OF THE
FLOOR AREA OF THE ROOM, PROVIDED THAT SUCH OPENING SHALL BE NOT LESS THAN ONE
SQUARE METER, EXCEPT THOSE IN TOILETS AND BATHS WHICH SHALL BE NOT LESS THAN ONETWENTIETH OF THE FLOOR AREA OF SUCH ROOMS, OR NOT LESS THAN 240 SQUARE
MILLIMETERS. STEEL CASEMENT FOR WINDOWS USING PLAIN GI SHEETS CAN BE USED TO
RESIST STRONG WIND FROM ENTERING INSIDE THE BUILDING THAT CREATES AN UPLIFT FORCE
THAT BLOW UP ROOFS. GI SHEETS ARE CONNECTED BY RIVETS AND NON-SAG MARINE EPOXY
OVER STEEL WINDOW FRAMES. ALL GLASS WINDOWS EASILY BREAKS AND CAN CAUSE INJURY
TO OCCUPANTS INSIDE WHEN BROKEN BY STRONG WINDS. (ENGR. RODEL VENERACION, PLAN
PHILIPPINES)
B. CEILING HEIGHT. THE CEILING HEIGHT OF ROOMS WITH NATURAL VENTILATION SHALL BE NOT
LESS THAN 2.70 METERS MEASURED FROM THE FLOOR TO THE CEILING; ROOMS PROVIDED WITH
ARTIFICIAL VENTILATION SHALL HAVE CEILING HEIGHTS NOT LESS THAN 2.40 METERS.
C. FLOOR CONSTRUCTION. ALL FLOORS SHALL BE SO FRAMED AND SECURED INTO THE
FRAMEWORK AND SUPPORTING WALLS SO AS TO FORM AN INTEGRAL PART OF THE WHOLE
BUILDING; THE TYPE OF FLOOR CONSTRUCTION USED SHALL PROVIDE MEANS TO KEEP THE BEAM
AND GIRDERS FROM LATERAL BUCKLING.
D. ROOF CONSTRUCTION. ALL ROOFS SHALL BE SO FRAMED AND TIED INTO THE FRAMEWORK AND
SUPPORTING WALLS SO AS TO FORM AN INTEGRAL PART OF THE WHOLE BUILDING; DARK
STOPS, ROOF DRAINS, FLUSHING, ETC., SHALL BE PROVIDED. PURLINS CAN BE MADE UP OF
ANGLE BARS INSTEAD OF THE CONVENTIONAL C-PURLINS WHERE TEXT SCREWS EASILY
LOOSENED RESULTING IN DETACHMENT OF ROOFS. THE THICKNESS OF THE ANGLE BAR SERVES
AS A KNOT, HOLDING TEXT SCREWS FIRMLY. PURLINS ARE SECURELY WELDED TO STEEL
TRUSSES CREATING A STURDY ROOF FRAMEWORK. (ENGR. RODEL VENERACION, PLAN
PHILIPPINES)
E. EXIT DOORS. AT LEAST TWO (2) EXIT DOORS ARE REQUIRED WHERE THE NUMBER OF ROOM
OCCUPANTS IS OVER 50 IN THE CASE OF CLASSROOMS, CONFERENCE ROOMS, EXHIBIT ROOMS,
GYMNASIA, SCHOOL SHOPS, VOCATIONAL INSTITUTIONS, LABORATORIES, AND AUDITORIUM; A
DOOR SHALL NOT BE LESS THAN 2.10 METERS HIGH AND 900 MILLIMETERS WIDE.
F. DOOR SHUTTERS. DOOR SHUTTERS SHALL BE SWING OUT AND BE CAPABLE OF OPENING AT
LEAST 90 DEGREES SO THAT THE CLEAR WIDTH OF THE EXIT WAY IS NOT LESS THAN 700
MILLIMETERS. NO DOOR SHUTTER SHALL EXCEED 1.20 METERS IN WIDTH.
G. CORRIDORS. EVERY CORRIDOR SHALL NOT BE LESS THAN 1.10 METERS WIDE AND SHALL BE
UNOBSTRUCTED.
H. STAIRWAYS. STAIRWAYS SERVING AN OCCUPANT LOAD OF 50 OR LESS MUST BE 1.10
METERS WIDE; THOSE SERVING MORE THAN 50 SHALL NOT BE LESS THAN 1.50 METERS. THE
RISE OF EVERY STEP SHALL NOT EXCEED 200 MILLIMETERS AND THE TREAD SHALL NOT BE
LESS THAN 250 MILLIMETERS. HANDRAILS SHALL BE PROVIDED ON EACH SIDE OF EVERY
STAIRWAY HAVING MORE THAN FOUR STEPS.