Sizing of The Swimming Pool Accessories

This document provides sizing calculations for various components of a swimming pool and gym heating system. It calculates the required volumes for the balance tank and filter beds. It determines the appropriate pump sizes, numbers of inlets/outlets, pipe diameters and heater capacity. The conclusions select component sizes and types based on the flow rates, heads and safety factors calculated from standard engineering formulas and references.

Uploaded by

AHMAD
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
100% found this document useful (5 votes)
2K views12 pages

Sizing of The Swimming Pool Accessories

This document provides sizing calculations for various components of a swimming pool and gym heating system. It calculates the required volumes for the balance tank and filter beds. It determines the appropriate pump sizes, numbers of inlets/outlets, pipe diameters and heater capacity. The conclusions select component sizes and types based on the flow rates, heads and safety factors calculated from standard engineering formulas and references.

Uploaded by

AHMAD
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 12

Sizing of balance (surge) tank of the swimming pool:

(volume = 40 liter / swimming pool surface area + 10 min of the filter flow rate + 0.01 x pool surface area )x 1.2
Pool area =
Average pool depth =
Pool volume =
Pool turn over =

23 m2
1.8 m
41.4 m3
6h

Pool flow rate =

6.9 m3/h

Surge tank volume =

2.8 m

1.9 L/s
about 10% of the pool volume

Conclusion:
We select a balance tank capacity of 6 m3
Balance tank dimensions: 1.75 x 1.75 x 2 m

Sizing of circulating pumps of the swimming pool:


Capacity =
Sand filter head loss =
Heater (heat exchanger) head loss =
Static head =
Piping and fitting head load loss =
Residual head =
Allawance factor =
Total pump head =

6.9
15
3
3
1
1
10
25

m3/h
m of water
m of water
m of water
m of water
m of water
%
m of wate

1.9 L/s
Source: Handbook of mechanical engineering calculations (page 15.51)
Source: Handbook of mechanical engineering calculations (page 15.51)

Source: Handbook of mechanical engineering calculations (page 15.51)

2.5 bar

Conclusion:
We select two identical centrifugal pumps
Type
Connection
Number
Flow rate
Head
Speed
Power

Centrifugal pumps
parallel
2 ( 1 duty and 1 standby)
20% Safety factor
2.3 L/s
2.5 bar
3500 rpm
2 Hp

Sizing of the required filter-bed area:


Filter rating =

23 m3/m2.h

Pool flow rate =

6.9 m3/h

Filter-bed area =

0.3 m2

1.9 L/s

Conclusion:
We select two identical high rate sand filters complete with face piping control valves and accessories
Flow rate
Effective filter area
Number of water inlets for the pool:

1.9 L/s
0.3 m2

Pool flow rate =


Practice flow rate through each inlet =
No. of Inlets =
Design speed =

6.9 m3/h
1 L/s
2
0.6 m/s

1.9 L/s
Source: Handbook of mechanical engineering calculations (page 15.51)

Conclusion:
We use four inlets distributed in the basin of the pool
No. of inlets

Flow rate through main return pipe

6.9 m3/h

1.9 L/s

Flow rate through each inlet


Main return pipe
Pipe connected to each inlet

3.5 m /h
3 Inch
1.5 Inch

0.5 L/s
Nominal diameter
Nominal diameter

Number of water main drain outlets for the pool:


Pool flow rate =
Main drain outlets No. =
Flow rate through each main drain =
Design speed =

6.9 m3/h
2
1.0 L/s
0.6 m/s

1.9 L/s

Conclusion:
We use two main drains at the lowest level of the pool basin
No. of main drains
2
Flow rate through main drain pipe

6.9 m3/h

1.9 L/s

Flow rate through each main drain


Main drain pipe
Pipe connected to each main drain

3.5 m3/h
3 Inch
2 Inch

1.0 L/s
nominal diameter

Checking sizing of the main pool drainage pipe to release the water in the pool:
Pool volume =
Release time =

41.4 m3
3h

Drainage flow rate =


Design speed =
Drainage main pipe diameter =

13.8 m3/h
1.2 m/s
3 Inch

3.83333 L/s

Number of overflow gutters of the pool.


Pool perimeter =
Design gutter spaced =
No. of gutters =
Design speed =
Flow rate through overflow main pipe =

30.6 m
4.6 m
7
0.6 m/s

Source: Handbook of mechanical engineering calculations (page 15.51)

5.2 m3/h

1.4 L/s

Source: Egyptian code for swimming pools page 79

Conclusion:
We use seven gutters for overflow system of the pool
No. of gutters
7
Flow rate through main overflow pipe

5.2 m3/h

1.4 L/s

Flow rate through each gutter


Main overflow pipe
Pipe connected to each gutter

0.7 m3/h
2.5 Inch
2 Inch

0.2 L/s
nominal diameter
nominal diameter

Sizing of circulating pump of the swimming pool and GYM electric heater:
Heater power =

125 kW

Temperature difference of the heater circulating water=


Flow rate of the heater circulating water =
Safety Factor=
Heater circulating pump flow rate =
Heater and heat exchanger head loss =
Piping and fitting head load loss =
Alawance factor =
Pump total head =

10
2.4
20
2.9
6
1
10
8

C
L/s
%
L/s
m of water
m of water
%
m of water

Conclusion:
We select two identical circulating pumps
Type
Connection
Number
Flow rate
Head
Speed
Power

Centrifugal pumps
parallel
2 ( 1 duty and 1 standby)
20% Safety factor
2.9 L/s
0.8 bar
1750 rpm
0.6 Hp

Sizing of the pipe that connect heat exchangers and electric heater:
Flow rate =
Speed =
Diameter =

2.9 L/s
1.2 m/s
2.5 Inch

Source: Handbook of mechanical engineering calculations (page 15.51)

0.8 bar

ng calculations (page 15.51)

Sizing of the heat exchanger of the swimming pool:


Entering water temperature =
Required pool temperature =
Pool volume =
Pool turn over =
Pool flow rate =
Heater Capacity (for storage type) =
Required time to heat up the pool =
Heater output power =
Heater input electric power =

10
27
41.4
6
6.9
1
24
34.0985
42.6231

C
C
m3
h
m3/h
m3
h
kW
kW

1.9 L/s
10 times circulating pump flow rate (l/min)
Heater output power = m*Cp*DT/time

Conclusion:
Heat exchanger has a heating capacity of 60 kW

ng pump flow rate (l/min)

wer = m*Cp*DT/time