Nokta Golden King User Manual English
Nokta Golden King User Manual English
Please don't keep the system box over the search coil.
Important
warnings
The quality of the received signal is related directly to its cleanness. The received
signal might be affected from many environmental factors like mineral intensive
soils, cold/hot weather, magnetic (electrical) noises etc. These factors cause the
received signal to be distorted. For this reason, we have developed a new
system called D.I.S.S that can clean the received signal no matter what the
reason of distortion is. What we get is always a clean sinusoid that is easy to
process.
Equipment Safety
Especially during transportation, do not forget that this is an electronic device and do
not expose it to harsh impacts.
Waterproofness
The system box of the equipment is not completely waterproof. It should not be exposed to
rain or soaked into water.
Proper Use
The accessories and connection components used on the equipment should be
connected and removed carefully.
Accessories and Batteries
Only use such batteries, headphones, camera recorder, gas sensor, cable and connection
components that are approved by Nokta Engineering. Use of any unapproved accessory
may damage your unit.
For consumers within the European Union: Do not dispose of this
equipment with the general household waste. The crossed wheeled bin
symbol on this equipment indicates that this unit should not be disposed
of with the general household waste but rather be recycled in compliance
with the local government regulations and the environmental requirements.
Special Regulations
Comply with the law and the regulations applicable to any given place.
Do not use the device at the protected areas and the military zones.
You should definitely inform the concerned authorities of any
cultural findings you may find during your search.
Battery
If you use another type of battery instead of that prepared by
Nokta Engineering which is equipped with protection circuits,
your unit may get damaged. Use the battery according to
the instructions written in the users manual prepared by
Nokta Engineering. Do not expose the battery to heat.
Environmental Effects
Do not let any other detector or unit that emits magnetic waves
closer than 10 meters to your device.
Installation
Your equipment is electronic and manufactured with high
technology. Because it is a sensitive device, do not attempt to install
or operate it before reading the users manual.
Use
Protect your device against external impacts.
Authorized Service
Only authorized personnel may repair your device. If the unit is
opened by the user, any third party or a repairman for any reason,
the equipment will no longer be covered under warranty.
Monitor
On the Golden King Deep Processor Radar system,
a 7 TFT screen with 800 X 480 resolution,
262.000 colors and 16-bit color depth is used.
Construction
The Golden King Deep Processor Radar is constructed with
thermoset engineering plastic. It has very high durability
and is affected by extreme hot and cold weather
conditions at a minimum level.
Ergonomics
Golden King Deep Processor Radar is designed ergonomically
for easy carriage and is appropriate for the human body.
Operating Manual
The Golden King Deep Processor Radar contains an
operating manual. The user can access the warnings about
the equipment, correct usage and other useful information by
selecting the operating manual from the settings menu.
Volume Setting
A stereo audio system is used on the Golden King
Deep Processor Radar.
Brightness Setting
On the Golden King Deep Processor Radar system, you can
set the TFT screen brightness through the brightness
setting menu.
Sensitivity
You can use the Golden King Deep Processor Radar
system at any depth you desire by setting the sensitivity
levelthrough the sensitivity menu.
Ferrous Setting
Camera Recorder
Interface Selection
Saving
Ground Balance
On the Golden King Deep Processor Radar, two alternatives
of ground balancing are provided. These are automatic and
manual ground balance menus.
Gas Sensor
Due to the gas sensor available on the Golden King Deep
Processor Radar system, you can check whether the
confined areas (caves, tunnels, cisterns, shelters) contain
methane gas or not that may adversely affect the human
health.
Signs
It is a menu which you can access through the signs menu
on the Golden King Deep Processor Radar where 406 signs
and symbols prepared by the experts are described, allowing
you to interpret the meanings of signs and symbols you may
come across during your search.
Information
On the Golden King Deep Processor Radar, whichever
menu or section you are in, when you press the info button,
you canaccess the description about that menu or section.
Contents
Unpacking
Ground balance
Equipment
1-2
Starting
Ground balance
Detection functions
Interface selection
Digital detection
Gauge detection
Result screen
Technical specifications
3
4
5
5-7
8
8
9-11
11
Start to use the camera recorder, the gas sensor, the search coils
and the headphones.
11-13
Use of the camera recorder
15-16
Use of the gas sensor
17
Use of the headphones
17-19
Use of the search coils
19
Ways and speed of detection
20
20-23
23
23
24-25
25-26
27
27
Menu descriptions
28-29
Sample use
30-36
Unpacking
Make sure all the parts are present.
System box
Extension pipe
Battery box
Charger
Leather case
Surface search coil (optional)
General search coil
Deep search coil (optional)
Camera Recorder (optional)
Gas sensor (optional)
Headphones
Equipment
System box
7 TFT monitor
Multi-functional keypad
Clamping apparatus
to adjust the monitor
angle
Gas sensor
socket input
Search coils
socket input
Speakers
Equipment
System Box
Battery
compaction apparattus
Starting
Initial steps to operate the equipment
BATTERY BOX
CHARGER
System
Warning
System On Off Buttons: When the battery protection switch is ON, your battery is
ready to operate / charge. If the battery will not be used for a long time the battery
protection switch should be switched to the OFF position. This way you will avoid
the battery to consume any power. If the battery protection switch is left on the ON
position when it is not used, it will both degrade the life of the battery and the
charge/discharge performance. Keep the battery protection switch on OFF when
you are not using your battery.
Warning Leds: There are 3 different colored LEDs on your battery.
Yellow LED: Flashing of the yellow LED indicates that the battery charge is low and the
system will shut itself down. You need to charge your battery to continue.
Green LED: The constant lighting indicates that the battery is charging. When the
battery is full, the flashing of the green LED indicates that the charging operation is
completed.
Red LED: When the battery is charging, if overheating occurs, the red LED will light
upand charging will be stopped in order to protect your battery. When it reaches
normal conditions the red LED will stop lighting and it will continue to charge again.
If the red LED does not go off for a long time, this means that there is an error or
short circuit in the system. Please call our technical service.
Starting
Assembly
The extension bar to which the armlet and the joystick are connected
is removed from the bag. The search coil is attached to the bobbin
connection component on the extension bar with the bobbin clamping
screws. The connector at the end of the extension bar is inserted in its
place on the search coil and the connector next to the armlet is inserted
in its place on the system box.
Armlet
Connector
System Box
Joystick
Connector
Search coil
Starting
On / Off Switch
After charging the battery, turn the system
off by pressing the OFF button and place the
battery box in its place on the system box.
Then, in order to turn on the system,
press the ON button on the battery box.
In order to turn off the system, first you need
to press the STANDBY button on the keypad.
Then you need to press the OFF button on the
battery.
Back Key
The function of the back key is to return to the previous
menu or to exit the current operation.
Starting
Ground Balance Key
This key is used to access the ground balance menu.
You can select either the automatic or the manual
option from the ground balance menu when needed.
Brightness Setting
Once the brightness setting key is pressed, it brings up
the brightness setting menu. In this menu, you can set
the screen brightness to any level you need.
OK Key
It is the key to confirm the operations made on the
menu screens.
Delete Key
It is used to delete previously made recordings.
Furthermore, it is used to delete any wrong letter or
number typed during recording.
Minus Key
It is used to change the effect of the ground in the
negative direction in the manual ground balance screen.
Up Direction Key
It is the up direction key to go up the options on the
menu screens.
Plus Key
It is used to change the effect of the ground in the
positive direction in the manual ground balance screen.
Confirm Button
The confirm button on the joystick is used to confirm
the operations the system warns the user for.
Starting
Numeric Keys
It is the multi-functional section
of the keypad. Especially at the
time of recording, it lets you
enter the Date / Region / Name
and the Time. Press the key
until the character you desire
appears on the screen. You can
delete any letter or number by
using the DEL key. After
entering a text or a number,
press the OK key to save.
Screen
Anti Glare
Brightness 450cd/m
Contrast Rate 400:1
Starting
Accessing Menu Functions
Detection
There are 2 methods to access the menu functions of the Golden King
Deep Processor Radar.
To search with the Golden King Deep Processor Radar, you should
select one of the two interface options.
68
METAL
DIGITAL
30
MINERAL
GAUGE
INTERFACE SELECTION
LANGUAGE SELECT
TECHNICAL MANUAL
Starting
Saving detections
You can save the findings obtained by the Golden King Deep Processor
Radar as well as the result screen reports and graphs. In order to save
the result screens, you can use the save key on the keypad.
If you do not want to save the result screen, press the BACK key and
return to the ground balance selection screen. When you press the
SAVE key, the following window will appear on the screen. You should
enter the required information on the window.
After digital or gauge detection, if you wish to save the result screens press
the save key on the keypad.
NAME
_________
REGION
_________
Starting
Accessing the stored data
In order to access the 3D RESULT and the CAMERA recordings
press the SAVE key on the keypad. The archives screen will appear on
your monitor.
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
CAMERA
3D
RESULT
CAMERA
DATE
NAME
REGION
0 2 /0 4 /2 0 0 8
RECORD1
I STAN B U L
0 5 /0 4 /2 0 0 8
RECORD2
ADANA__
1 1 /0 4 /2 0 0 8
RECORD3
BITLIS__
1 6 /0 4 /2 0 0 8
RECORD4
HATAY_ _
2 9 /0 4 /2 0 0 8
RECORD5
EDIRNE_
ARCHIVES SCREEN
There are two tabs in the archive menu. These are the 3D RESULT tab and
the CAMERA tab. Using the right/left direction keys, you can
select one of these tabs and you can access the CAMERA or the
3D RESULT records when you press the OK key.
After selecting one of the records using the up/down direction keys and by
pressing the OK key, you can watch the video that you have recorded.
Please use the BACK key in order to exit this window. Please use the
DEL key in order to delete any of the entries after selecting it with the
up/down direction keys.
10
Starting
DATE
NAME
REGION
0 2 /0 4 /2 0 0 8
3D R E C O R D 1
I STAN B U L
0 5 /0 4 /2 0 0 8
3D R E C O R D 2
ADANA__
1 1 /0 4 /2 0 0 8
3D R E C O R D 3
BITLIS__
1 6 /0 4 /2 0 0 8
3D R E C O R D 4
HATAY_ _
2 9 /0 4 /2 0 0 8
3D R E C O R D 5
EDIRNE_
After selecting one of the records using the up/down direction keys, press
the OK key to view the 3D result screen. Please use the BACK key
in order to exit this window. Please use the DEL key in order to delete
any of the entries after selecting it by the up/down direction keys.
Use
The camera recorder with its 30m cable comes with your device,ready
for use. After you remove the camera recorder from its bag, insert the
socket at the end of the cable into the camera recorders input jack. Then,
press the camera recorder key located on the keypad. Within seconds,
your system will sense the camera recorder and transfer the image to the
monitor. After this step, your camera recorder is ready to operate.
11
PLAY
_ _ /_ _ /_ _ _ _
NAME
_________
REGION
_________
After entering the date, name and the region information and pressing the
OK key, the recording starts. In order to stop the recording, you can use
the STOP button. You can use the BACK key in order to quit without
recording and to return to the preview mode.
REC
REC BUTTON
When the REC button is pressed, the camera is switched from the preview
mode to the record mode. By selecting the REC button with the up/down
direction keys and by pressing the OK key, the record window below will
appear on the screen.
PLAY
PLAY BUTTON
In order to watch the videos you have recorded please select the PLAY
button with the up/down direction keys and press the OK button. When
you press the PLAYbutton all the videos you have recorded will appear
on the screen.
12
PAUSE
PAUSE
STOP
DATE
NAME
PAUSE BUTTON
REGION
0 2 /0 4 /2 0 0 8
RECORD1
I STAN B U L
0 5 /0 4 /2 0 0 8
RECORD2
ADANA__
1 1 /0 4 /2 0 0 8
RECORD3
BITLIS__
1 6 /0 4 /2 0 0 8
RECORD4
HATAY_ _
2 9 /0 4 /2 0 0 8
RECORD5
EDIRNE_
When viewing the saved videos, you can pause any moment
of the video indefinitely by using the PAUSE button. This way,
you can view the videos you have recorded in more detail. By pressing
the PAUSE button again, you can continue watching the video.
The user can select the desired video with the up/down direction keys.
Then, the video can be watched by pressing the OK key.
STOP
13
X BUTTON
X BUTTON
If slower viewing is needed, press the X button to watch the video
recorded on 30 fps as 7 fps.
The video will now play at 1/4 of the normal speed.
When viewing the videos you have recorded, your system is designed to
display 30 frames per second (fps). This frame speed is the standard video
format. When you want to watch the video in slow motion, the system offers
two alternatives to the user. First is the X button. With the up/down
direction keys, select the X button and activate it with the OK
key. The video will now play at half of the normal speed.
PAUSE
STOP
PAUSE
X
STOP
X
X
14
Gas Sensor
The Golden King Deep Processor Radar system is equipped with a gas
sensor which measures and informs the user of the presence of methane gas
which is one of the flammable, explosive and toxic gases in confined places.
The connector of the gas sensor is inserted into the gas sensor input on the
system box. Then,the gas sensor key on the keypad is pressed.
The gas sensor menu appears on the screen.
GAS SENSOR
15
Gas sensor
socket input
GAS SENSOR
02:20
GAS SENSOR
GAS SENSOR
Press BACK to exit the gas sensor menu.
16
Volume button
There is a different search coil for every need. The Golden King Deep
Processor Radar provides you with three types of search coils. You will be
able to attach these search coils within seconds with the provided connectors
when needed.
SMART DETECTION is one of the features which makes the Golden King
Deep Processor Radar unique worlwide. When you turn on the SMART
DETECTION system, it gets activated right away and it observes all your
moves until the completion of your search. Due to the high display
technology it uses, the user can view his/her moves in real time on the monitor.
17
The Smart Search Coils and the entire Golden King Deep Processor Radar
system have been developed after comprehensive R&D activities, both
electronical and chemical. Thermoset engineering plastic is used on the
entire system and on the Search Coils. They are developed perfectly to resist
the bad weather conditions such as hot, cold and humid as well as water and
moist.
18
Confirm
19
Ground Balance
Ground Balance
On the Golden King Deep Processor Radar system, ground balancing is done
through the GROUND BALANCE menu. You can access the ground
balance menu both from the settings section or by pressing the
GROUND BALANCE key on the keypad.
OK
What you need to do is to eliminate the soil in the box on the left side of the
screen and turn it to green and save it by pressing the OK button.
Method:
AUTOMATIC
MANUEL
GROUND SETTING
When GROUND BALANCE is selected, you will see two tabs. These tabs are
AUTOMATIC and MANUAL ground balance tabs. You may switch from one
tab to another with the right/left direction keys. You can select the one you want
by pressing the OK key. The option you select will turn to red.
What you should do next is to raise the search coil about 40 centimeters
above the ground and press the RESET button.
RESET
40cm
Reset Button
When the AUTOMATIC GROUND BALANCE is selected, you will see the
interface on the top right of the page.
40cm
20
Ground Balance
After pressing the RESET button, following the animated guide on the screen,
hold your search coil about 10cm above the ground again and press the
CONFIRM button. Please wait until the clock on the screen makes one
complete turn after pressing the CONFIRM button.
Please continue these steps until the box with the soil on the left side
completely turns to green. The soil in the box will decrease each time you
follow these steps depending on the mineral composition of the ground.
The ground balance will be completed as soon as the box completely turns to
green. You can switch to the search screen by pressing the OK button.
GROUND
NOT SET
DECREASING
EFFECT
DECREASING
EFFECT
DECREASING
EFFECT
GROUND
SET
CONFIRM
10cm
10cm
What you should do now is to raise the search coil to 40cm above
the ground again. When you press the RESET button, the animated guide
will lower the search coil down to 10cm above the ground again and so should
you. Each time you lower your search coil to the ground and press the
CONFIRM button, the box with the soil on the left side of the screen will
start turning to green.These steps should continue until the box completely
turns to green as shown on the right side. When the box is completely green,
it means that the ground balancing has been completed succesfully.
Confirm Button
Reset Button
RESET
40cm
The system will switch to the general detection mode when you press the
OKbutton. The system will not switch to any screen until you press the
OK button.
40cm
21
Ground Balance
Raise the search coil 40cm above the ground and press the - / + key on the
keypad for an estimated number of times to eliminate the effect.
Because the effect is in the positive direction in the example below, you should
press the + key. If the incoming effect was negative, then you would press
the - key.
NEGATIVE
POSITIVE
40cm
POSITIVE
Now press the RESET button, release and lower the search coil to 10cm
above the ground again.
NEGATIVE
On this screen, there is a level indicator that can receive the effect of the
ground in both directions, - Negative and + Positive. When you hold the
search coil above the ground for the first time, the system is affected from the
mineral level of the ground in the negative or the positive direction.
The purpose is to eliminate this effect coming from the ground.
Method: Detection coil is held 10cm. above the ground. Let's say that we
we have received an effect from the ground in the positive +direction.
NEGATF
POSITIVE
10cm
You see that the effect coming from the ground is less now. Repeat these
steps until you receive no effect from the ground. When the effect is completely
eliminated, save the ground setting by pressing the OK button.
POZTF
10cm
22
Ground Balance
Detection Functions
RESET BUTTON
Interface Selection
The Golden King Deep Processor Radar system offers two types of detection
interfaces. First one is DIGITAL and the second one is GAUGE interface.
The user can search by selecting the interface which he/she will use most
conveniently. These interfaces can be changed anytime through the interface
selection menu.
RESET BUTTON
The reset button will bring all the detection settings of your system to the
settings when you made the ground balance. Reset should not be used when
you are on the target signal. Otherwise, it may cause loss of depth and
misinterpretation of the signal.
The reset operation should be performed when the coil is away from the
target. You are recommended to reset after each operation.
Note:
When ground balance cannot be performed completely due to high levels
of minerals, return to the SENSITIVITY menu and reduce the sensitivity
level. Continue this operation until you can do the ground balance
completely.
Note:
Ground balance should be performed on a ground where there is no
metal or cavity. Otherwise, the equipment will detect that you are on a
metal or cavity and will warn you accordingly. In such a case, change your
location and do it again.
GOLDEN
68
METAL
DIGITAL
30
MINERAL
GAUGE
INTERFACE SELECTION
You can select the interface you want from the menu above with the
right/left direction keys. You can save the interface you have selected by
pressing theOK button.
23
Detection Functions
DIGITAL DETECTION
Nokta
ENGINEERING
GENERAL DETECTION
YOU DETECTED A TARGET!
PLEASE HOLD CONFIRM BUTTON AND PASS
OVER THE TARGET TO GET ALL INFORMATION
ABOUT THE TARGET.
SCOPE SCREEN
With the Golden King Deep Processor Radar, you will easily follow
the amplitude of the target signal in real time on the SCOPE Screen.
On this screen, you will both see the highest amplitude point of the signal
center in real time and examine the signal graphs of both the cavities and the
metal targets.
The digital detection interface named as General Detection consists of the parts
and sections below and on the right side. Now we will explain these sections
which will give you the initial data about the target signal during your searches.
RADAR SCREEN
Another new feature of the Golden King Deep Processor Radar is the
RADAR SCREEN. Due to this screen, while the user is following the operation
of the system, he/she will also have information about the target based on the
color changes of the RADAR SCREEN when a metal / a cavity
(negative/positive) signal is detected. The RADAR SCREEN turns to red in
case of a positive (metal) signal. In case of a negative (cavity) signal,
it turns to blue. This way the user is given initial data about the target which
enables the user to search more quickly.
24
Detection Functions
YOU DETECTED A TARGET !
PLEASE HOLD CONFIRM BUTTON AND PASS
OVER THE TARGET TO GET ALL INFORMATION
ABOUT THE TARGET.
GOLD
73
CAVITY
21
MINERAL
68
METAL
min
30
max
23
MINERAL
REPORT SCREEN
The Golden King Deep Processor Radar communicates the initial data
received from the target signal and the following steps to be performed
through the REPORT SCREENS. The report screen not only gives information
about the target signal, but it also guides the user regarding the system
warnings as well as the following steps to be performed.
Like a private guide always at your side, the REPORT SCREEN will be a
partner working together with you throughout your searches and detections,
giving you all the information you need and checking all your actions for
accuracy.
GOLD
68
METAL
GOLD
68
METAL
GAUGE DETECTION
30
MINERAL
The Gauge option on the Golden King Deep Processor Radar system has
been designed as a convenient detection interface, considering the users old
habits about the former systems. All sections present in the general detection
(DIGITAL DETECTION) are available here but represented by a gauge system
instead.
30
MINERAL
25
Detection Functions
YOU DETECTED A TARGET!
PLEASE HOLD CONFIRM BUTTON AND PASS
OVER THE TARGET TO GET ALL INFORMATION
ABOUT THE TARGET.
73
CAVITY
21
MINERAL
REPORT SCREEN
Searching with the gauge screen of the Golden King Deep
Processor Radar is very clear and pleasant. While you see the clear
information received from the target signal on the report screen, you will also
be informed about the following steps to be performed.
ALTIN
min
max
23
SCOPE SCREEN
During your searches with the Golden King Deep Processor Radar, you will
easily follow the amplitude of the the target signal in real time on the
SCOPE Screen. On this screen, you will determine the highest amplitude
point of the signal center in real time and examine the signal graph of both the
cavity and the metal targets. Unlike the general detection, you can observe the
highest point of the target signal when you use the gauge detection.
The highest point that the pointer reaches represents the center of the target
signal.
73
CAVITY
21
MINERAL
68
METAL
30
MINERAL
min
max
23
YOU DETECTED A TARGET!
PLEASE HOLD CONFIRM BUTTON AND PASS
OVER THE TARGET TO GET ALL INFORMATION
ABOUT THE TARGET.
26
Technical Characteristics
Result Screen
Result Screen
You can examine the 3D graph of the target signal on the result screen of
the Golden King Deep Processor Radar in real time. On the result screen, there
are 3 graph windows. 1st window is the top view of the signal, 2nd window is
the side view of the signal and the 3rd window is the perspective view of the
signal.
On the vertical guide scale to the left of the 3D perspective image, you can see
the amplitude of the target signal. Again on the horizontal guide scale to the left,
you can see the width of the scan area. On the horizontal scale located at the
bottom part, you can see the length of the scan area.
Again by referring to these guide scales, you can see the estimated width and
length of the signal. From the report section on the right side of the result
screen, you can get information about the signal. In order to view the
3D graph in full screen please press the 1 key on the keypad. After switching
to the full screen mode, you can use the 2, 3 and4 keys to view the 3D
graph from different angles. When you press the BACK key, the system will
return to the search screen automatically.
RESULT SCREEN
TARGET SIGNAL
NONFERROUS METAL
GOLD
CAVITY SIGNAL IS RECEIVED
ALONG WITH METAL SIGNAL
TARGET SIGNAL
STARTING DEPTH
100CM
TO EXAMINE
SIGNAL ON FULL DISPLAY
YOU MAY USE 1 KEY,
TO VIEW AT DIFFERENT
ANGLES YOU MAY USE
THE KEYS 1 2 3 ON
THE NUMERATOR
METAL
MINERAL
METALLIC
DIFFUSION
CAVITY
Detection Coil
210 x 315
360 X 440
600 X 1000
Frequency
12.5 kHz
12.5 kHz
12.5 kHz
TFT
TFT
TFT
5x5
60 cm
85 cm
80 cm
10 x 10
80 cm
110 cm
120 cm
20 x 20
115 cm
140 cm
160 cm
30 x 30
140 cm
182 cm
215 cm
40 x 40
155 cm
220 cm
245 cm
60 x 60
185 cm
270 cm
305 cm
80 x 80
225 cm
295 cm
350 cm
100 x 100
245 cm
335 cm
410 cm
Screen
WIDTH (cm)
27
Menu Description
LANGUAGE SELECTION
OPERATING MANUAL
+100
VOLUME MENU
VOLUME MENU:
To set the audio volume of the system, use
the volume control consisting of 10
levels in the volume menu. In this menu,
you can increase and decrease the volume
as you wish.
+100
BRIGHTNESS MENU:
In this menu, you can adjust the brightness
of the screen. You can increase or
decrease the brightness as you wish.
BRIGHTNESS SETTING
+100
SENSITIVITY MENU:
It is for setting the depth of the system to
your need. Especially when ground balance
is hard to achieve due to high levels of
minerals in the ground, reduce the sensitivity
and do the ground balancing again.
SENSITIVITY SETTING
ON
OFF
FERROUS SETTING
28
Menu Descriptions
GOLD
68
METAL
DIGITAL
30
MINERAL
GAUGE
INTERFACE SELECTION
AUTOMATIC
MANUEL
GROUND BALANCE
GAS SENSOR
CAMERA
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
CAMERA
3D
RESULT
ARCHIVES SCREEN
SIGNS
SIGNS MENU:
The signs menu contains the meanings of
hundreds of signs you may come across
on site during your search. There are
406 symbols and signs, together with
their meanings, present in the system.
29
Exemplary Use
WARNING
LANGUAGE SELECTION
30
4
+100
BRIGHTNESS SETTING
FERROUS SETTING
31
GROUND BALANCE
10
MAKSMUMUPPER
ST SEVYE
MAXIMUM
LEVEL
MAKSMUM
ST SEVYE
MXIMUM
LOWER
LEVEL
40cm
Reset Button
OK
10CM
10cm
RESET
40cm
40CM
32
12
11
Confirm Button
MAXIMUM
UPPER
LEVEL
MAKSMUM
ST SEVYE
Reset Button
CONFIRM
10cm
RESET
40cm
40cm
10cm
13
14
Confirm Button
MAKSMUM
ST SEVYE
MAXIMUM
UPPER
LEVEL
Reset Button
CONFIRM
10cm
10cm
RESET
40cm
40cm
33
15
16
Confirm Button
CONFIRM
10cm
17
18
Confirm Button
Confirm Button
34
19
20
Confirm Button
Confirm Button
Reset Button
Reset Button
21
22
Confirm Button
35
23
24
IF YOU DESIRE TO SAVE 3D RESULT
SCREEN, PRESS SAVE KEY ON THE
KEYPAD.
DATE
_ _ /_ _ /_ _ _ _
NAME
_________
REGION
_________
25
26
PLEASE ENTER DATE / NAME / REGION
INFO BY USING LETTERS AND NUMBERS
ON THE KEYPAD.
NAME
000000001
REGION
DATE
_________
1 1 /0 1 /2 0 0 8
NAME
VIDEO 1
REGION
HAKKARI__
36
ATTENTION!
The Golden King Deep Processor Radar is the best system produced so far among the systems that receive data from underground.
The detector and radar systems delivering 100% performance on land or in the sea do not operate with 100% accuracy underground.
Scientifically, it is not possible to get 100% accurate results.
With respect to the results it gives, the Golden King Deep Processor Radar is the ultimate point in technology.
Results on all these systems may vary depending on the use, weather conditions, mineral levels in the ground and the environmental effects.
Our company is not responsible for any of the above affecting the performance of the Golden King Deep Processor Radar.
On the Golden King Deep Processor Radar, the interpretations of the detections made by our system are the best interpretations allowed by the current
technology. These interpretations are for assisting the user. These results are not definite. They are accurate to the extent technologically feasible.
Data and the depth values given in the technical manual of the Golden King Deep Processor Radar system are obtained at a laboratory.
This data may vary on the search field. Metals do not emit magnetic field by themselves unless they are excited. Metals buried in the ground come into a
chemical reaction, which we also refer to as rusting, with the minerals and the metal compounds in the soil. As a result of this reaction, an electrolysis flow
occurs between the metal and the soil and the metal becomes subject to corrosion, forming a composition with the minerals or the metals of the ground.
And this phenomenon positively affects the detection distance for the detectors.
The pH value of the soil and the mineral it contains as well as the rich metal structure are factors leading to fast or slow reaction. For this reason, big metals
at depths which normally cannot be detected may be detected by the GOLDEN KING DEEP PROCESSOR RADAR at depths up to 8m provided that
the above-mentioned conditions are present.
Nokta Engineering