1. Fully charge the battery for 3-4 hours by plugging the charger into a 220V wall socket 2. Assemble the system box, extension pipe, battery box, and search coil 3. Power on the device using the on/off switch and access the menu functions using the multi-functional keypad 4. Select detection modes and additional features like the camera recorder or gas sensor to begin detecting targets
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
722 views44 pages

Nokta Golden King User Manual English

1. Fully charge the battery for 3-4 hours by plugging the charger into a 220V wall socket 2. Assemble the system box, extension pipe, battery box, and search coil 3. Power on the device using the on/off switch and access the menu functions using the multi-functional keypad 4. Select detection modes and additional features like the camera recorder or gas sensor to begin detecting targets
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 44

TECHNICAL MANUAL

Please don't keep the system box over the search coil.

Important
warnings

If these warnings are not


duly observed, your
equipment may get damaged.

During each power-up, the Golden King


Deep Processor Radar system should be
held as shown in the picture. The 'ON' key
should be pressed in this position.
After pressing the 'ON' key, keep your
position still for approximately 20
seconds. Then lower the search coil to
the normal searching height, press
'RESET' and release.
When the above process is finished you can
do the ground balancing and start your
search. During this process, the system
adopts itself to the surrounding conditions
and makes all the necessary reference
adjustments for better searching.

The quality of the received signal is related directly to its cleanness. The received
signal might be affected from many environmental factors like mineral intensive
soils, cold/hot weather, magnetic (electrical) noises etc. These factors cause the
received signal to be distorted. For this reason, we have developed a new
system called D.I.S.S that can clean the received signal no matter what the
reason of distortion is. What we get is always a clean sinusoid that is easy to
process.

The depth of the system is excessive. Therefore it can


sense the system box as a target. Keep the system box
away from the search coil.

Please keep your search coil away from

your shoes. The system can sense the metals in


your shoes as a target.

Please do not apply force to the search coil input


connector with your hand when the system is operating.
Do not stretch the cable, do not apply force to the

connection socket. In order to interpret the target signal


accurately you must follow the warnings.

Equipment Safety
Especially during transportation, do not forget that this is an electronic device and do
not expose it to harsh impacts.
Waterproofness
The system box of the equipment is not completely waterproof. It should not be exposed to
rain or soaked into water.
Proper Use
The accessories and connection components used on the equipment should be
connected and removed carefully.
Accessories and Batteries
Only use such batteries, headphones, camera recorder, gas sensor, cable and connection
components that are approved by Nokta Engineering. Use of any unapproved accessory
may damage your unit.
For consumers within the European Union: Do not dispose of this
equipment with the general household waste. The crossed wheeled bin
symbol on this equipment indicates that this unit should not be disposed
of with the general household waste but rather be recycled in compliance
with the local government regulations and the environmental requirements.

Special Regulations
Comply with the law and the regulations applicable to any given place.
Do not use the device at the protected areas and the military zones.
You should definitely inform the concerned authorities of any
cultural findings you may find during your search.

Battery
If you use another type of battery instead of that prepared by
Nokta Engineering which is equipped with protection circuits,
your unit may get damaged. Use the battery according to
the instructions written in the users manual prepared by
Nokta Engineering. Do not expose the battery to heat.

Operation of the Unit


Do not start searching before doing ground balancing.
Results obtained without ground balancing will not be accurate.

Environmental Effects
Do not let any other detector or unit that emits magnetic waves
closer than 10 meters to your device.

Hot and Cold


Do not expose your device and search coils directly to fire. Do not
keep them in a very cold environment for a long period of time.
Important Note: If the lithium polymer battery used on the
system is exposed to high heat or direct sunlight, it may get
damaged. Never leave it inside a car in hot weather. Short
circuiting of the lithium polymer battery may also cause
it to get damaged.

Installation
Your equipment is electronic and manufactured with high
technology. Because it is a sensitive device, do not attempt to install
or operate it before reading the users manual.

Use
Protect your device against external impacts.

Authorized Service
Only authorized personnel may repair your device. If the unit is
opened by the user, any third party or a repairman for any reason,
the equipment will no longer be covered under warranty.

Features of the Equipment


Language Selection

Monitor
On the Golden King Deep Processor Radar system,
a 7 TFT screen with 800 X 480 resolution,
262.000 colors and 16-bit color depth is used.

Construction
The Golden King Deep Processor Radar is constructed with
thermoset engineering plastic. It has very high durability
and is affected by extreme hot and cold weather
conditions at a minimum level.

Ergonomics
Golden King Deep Processor Radar is designed ergonomically
for easy carriage and is appropriate for the human body.

Smart Detection Heads


On the Golden King Deep Processor Radar, there are 3 types
of search coils suitable for every purpose. The search coils
detect every move of the user and minimize the negative
results due to wrong usage of the device.

The Golden King Deep Processor Radar can operate in


10 different languages: Turkish, English, Greek, Persian,
Bulgarian, French, Spanish, German, Russian and Arabic.

Operating Manual
The Golden King Deep Processor Radar contains an
operating manual. The user can access the warnings about
the equipment, correct usage and other useful information by
selecting the operating manual from the settings menu.

Volume Setting
A stereo audio system is used on the Golden King
Deep Processor Radar.

Brightness Setting
On the Golden King Deep Processor Radar system, you can
set the TFT screen brightness through the brightness
setting menu.

Sensitivity
You can use the Golden King Deep Processor Radar
system at any depth you desire by setting the sensitivity
levelthrough the sensitivity menu.

Features of the Equipment

Ferrous Setting

Camera Recorder

During your search with the Golden King Deep


Processor Radar, you can search by switching
the ferrous setting to OFF to avoid ferrous metals
(iron, nail, beverage bottle caps, etc.).

The Golden King Deep Processor Radar is equipped with


a special camera recorder as an attachable accessory which
operates at a very high display quality even 30 meters under
water, has night vision, thus allowing use both on
land and under water.

Interface Selection

Saving

When searching with the Golden King Deep Processor Radar,


you can select either the digital detection or the gauge
detection interface, whichever is more suitablefor your needs.

With the Golden King Deep Processor Radar system,


you can save the result screens and the videos you have
recorded and you can access them anytime for review
purposes.

Ground Balance
On the Golden King Deep Processor Radar, two alternatives
of ground balancing are provided. These are automatic and
manual ground balance menus.

Gas Sensor
Due to the gas sensor available on the Golden King Deep
Processor Radar system, you can check whether the
confined areas (caves, tunnels, cisterns, shelters) contain
methane gas or not that may adversely affect the human
health.

Signs
It is a menu which you can access through the signs menu
on the Golden King Deep Processor Radar where 406 signs
and symbols prepared by the experts are described, allowing
you to interpret the meanings of signs and symbols you may
come across during your search.

Information
On the Golden King Deep Processor Radar, whichever
menu or section you are in, when you press the info button,
you canaccess the description about that menu or section.

Contents
Unpacking

Ground balance

Make sure all the parts are present.

Equipment

1-2

Keys - features and locations

Starting

Initial steps to operate the equipment


Preparing and charging the equipment
Assembly
On / Off Switch
Keys and screen
Accessing the menu functions
Detection
Saving detections

Use of Additional Features

Ground balance

Detection functions
Interface selection
Digital detection
Gauge detection
Result screen

Technical specifications
3
4
5
5-7
8
8
9-11
11

Start to use the camera recorder, the gas sensor, the search coils
and the headphones.
11-13
Use of the camera recorder
15-16
Use of the gas sensor
17
Use of the headphones
17-19
Use of the search coils
19
Ways and speed of detection

20
20-23
23
23
24-25
25-26
27
27

Menu descriptions

28-29

Sample use

30-36

Unpacking
Make sure all the parts are present.

System box
Extension pipe
Battery box
Charger
Leather case
Surface search coil (optional)
General search coil
Deep search coil (optional)
Camera Recorder (optional)
Gas sensor (optional)
Headphones

All these parts can be obtained from the


dealers of Nokta Engineering.
Please do not use any external or any
other branded item.

Equipment
System box

7 TFT monitor

Multi-functional keypad

Clamping apparatus
to adjust the monitor
angle

Gas sensor
socket input

Search coils
socket input

Speakers

Equipment

System Box

Camera recorder input

Headphones socket input

Gas sensor socket input


Battery

Search coil socket input


Battery
compaction apparattus

Battery
compaction apparattus

Plug it into a 220V wall socket.

Starting
Initial steps to operate the equipment

Preparing and charging the equipment


You are required to charge the battery before initial use.
The battery should be charged for about 3-4 hours.
Under normal conditions, the battery should allow 5-6 hours of operation.
For soils containing high density of minerals, this term reduces down
to 4-5 hours.
Note: The battery charger used on the system is equipped with a special
software. Due to this software, the battery is charged in sequence.
For the first several charging operations, the duration of the operation
will be shorter than the normal values. When it is charged again and again,
it will reach to the values indicated above.

BATTERY BOX

CHARGER

The battery box is removed by opening the clamping apparatus on the


system box. The socket of the charger is plugged into the charger input
on the battery box. The plug of the charger is inserted into the wall socket.
Charger input

The system Battery


Full
is active

System
Warning

System On/Off Buttons

System On Off Buttons: When the battery protection switch is ON, your battery is
ready to operate / charge. If the battery will not be used for a long time the battery
protection switch should be switched to the OFF position. This way you will avoid
the battery to consume any power. If the battery protection switch is left on the ON
position when it is not used, it will both degrade the life of the battery and the
charge/discharge performance. Keep the battery protection switch on OFF when
you are not using your battery.
Warning Leds: There are 3 different colored LEDs on your battery.
Yellow LED: Flashing of the yellow LED indicates that the battery charge is low and the
system will shut itself down. You need to charge your battery to continue.
Green LED: The constant lighting indicates that the battery is charging. When the
battery is full, the flashing of the green LED indicates that the charging operation is
completed.
Red LED: When the battery is charging, if overheating occurs, the red LED will light
upand charging will be stopped in order to protect your battery. When it reaches
normal conditions the red LED will stop lighting and it will continue to charge again.
If the red LED does not go off for a long time, this means that there is an error or
short circuit in the system. Please call our technical service.

Starting
Assembly

The extension bar to which the armlet and the joystick are connected
is removed from the bag. The search coil is attached to the bobbin
connection component on the extension bar with the bobbin clamping
screws. The connector at the end of the extension bar is inserted in its
place on the search coil and the connector next to the armlet is inserted
in its place on the system box.
Armlet

Connector

System Box

Joystick

Connector

After the battery is taken out of the bag, it is installed in its


place on the system box by the connection screws.

Search coil

After completion of these steps, adjust the length of the detection


system to your height by using the sleeves on the extension bar.
Now the system is ready for use.

Starting

Keys and Screen


Standby Key
It is the key to turn off the entire system.

On / Off Switch
After charging the battery, turn the system
off by pressing the OFF button and place the
battery box in its place on the system box.
Then, in order to turn on the system,
press the ON button on the battery box.
In order to turn off the system, first you need
to press the STANDBY button on the keypad.
Then you need to press the OFF button on the
battery.

Back Key
The function of the back key is to return to the previous
menu or to exit the current operation.

System On/Off Buttons

Camera Recorder Key


After the camera recorders socket is inserted into the
camera recorders input jack, the camera recorder can be
used by pressing this key.
Recording Key
When this key is pressed, recording and archive screens
appear. You can record the result screens and the videos on
this screen. Furthermore, you can use the archive section to
access the previously recorded information.
Gas Sensor Key
After the gas sensors socket is inserted into the gas
sensor jack on the system box, press this button to take
advantage of the gas sensor function.
Info Key
Whichever menu or section you are in, when you press
the info key, you will view detailed information about that
section or menu. Also in this section, the user will be
informed about the following steps.

Starting
Ground Balance Key
This key is used to access the ground balance menu.
You can select either the automatic or the manual
option from the ground balance menu when needed.

Left Direction Key


It is the left direction key to go leftward on the options
on the menu screens.

Brightness Setting
Once the brightness setting key is pressed, it brings up
the brightness setting menu. In this menu, you can set
the screen brightness to any level you need.

Right Direction Key


It is the right direction key to go rightward on the
options on the menu screens.

Sunlight Mode Key


When the sunlight is intensive and it affects the screen
image, you will see the sunlight mode of this screen
come up when this key is pressed which minimizes the
effect of the sunlight. The system switches to this mode.

OK Key
It is the key to confirm the operations made on the
menu screens.

Delete Key
It is used to delete previously made recordings.
Furthermore, it is used to delete any wrong letter or
number typed during recording.

Minus Key
It is used to change the effect of the ground in the
negative direction in the manual ground balance screen.

Up Direction Key
It is the up direction key to go up the options on the
menu screens.

Plus Key
It is used to change the effect of the ground in the
positive direction in the manual ground balance screen.

Down Direction Key


It is the down direction key to go down the options
on the menu screens.

Confirm Button
The confirm button on the joystick is used to confirm
the operations the system warns the user for.

Starting
Numeric Keys
It is the multi-functional section
of the keypad. Especially at the
time of recording, it lets you
enter the Date / Region / Name
and the Time. Press the key
until the character you desire
appears on the screen. You can
delete any letter or number by
using the DEL key. After
entering a text or a number,
press the OK key to save.

Screen

Do not expose your monitor to fire directly.

Protect your monitor against excessive hot,


excessive cold or rain.

Your monitor is fragile, please handle it gently.


7 TFT
262.000 Colors
800 X 480 Resolution
16-Bit Color Depth

Your monitor can get scratched, please handle it gently.

Anti Glare
Brightness 450cd/m
Contrast Rate 400:1

Starting
Accessing Menu Functions

Detection

There are 2 methods to access the menu functions of the Golden King
Deep Processor Radar.

To search with the Golden King Deep Processor Radar, you should
select one of the two interface options.

Method 1: Is the multi-functional keypad on the system box.


You can access the menu functions by using the keys here.
GOLD

68
METAL

DIGITAL

30
MINERAL

GAUGE

INTERFACE SELECTION

Method 2: Is to access the menu functions by using the buttons on the


settings menu, the directional arrows, the OK key and the BACK key.
You can navigate among the menus by using the up/down direction keys in
the settings menu; enter the menu by using the OK key; navigate among
the options by using the right - left direction keys, and access the functions
of the option you have selected by using the OK key. When you want to
go back from the menus and the options you are in, you can return to the
previous menu by pressing the BACK key.

LANGUAGE SELECT

Select one of the options - DIGITAL or GAUGE - and activate the


option you have selected by pressing the OK key. This selection is kept in
memory at the initial use and it is used as the default detection interface
unless it is changed by the user.
NOTE: You can learn how to search using the interfaces by following
the directions in the operating manual of the Golden King Deep
Processor Radar or by reading the technical manual.

TECHNICAL MANUAL

Starting

Saving detections
You can save the findings obtained by the Golden King Deep Processor
Radar as well as the result screen reports and graphs. In order to save
the result screens, you can use the save key on the keypad.

If you do not want to save the result screen, press the BACK key and
return to the ground balance selection screen. When you press the
SAVE key, the following window will appear on the screen. You should
enter the required information on the window.

After digital or gauge detection, if you wish to save the result screens press
the save key on the keypad.

PLEASE ENTER DATE / NAME / REGION


INFO BY USING LETTERS AND NUMBERS
ON THE KEYPAD.
DATE
_ _ /_ _ /_ _ _ _

NAME
_________

REGION
_________

AFTER COMPLETION OF NAMING,


PRESS OK KEY.

Starting
Accessing the stored data
In order to access the 3D RESULT and the CAMERA recordings
press the SAVE key on the keypad. The archives screen will appear on
your monitor.

101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101

CAMERA

3D
RESULT

CAMERA

CAMERA MENU: You can watch the videos you have


previously recorded in the Golden King Deep Processor Radar
system. In order to watch a video , please press the SAVE
key on the keypad. Using the right/left direction keys
you can select the CAMERA tab and press the OK key.

DATE

NAME

REGION

0 2 /0 4 /2 0 0 8

RECORD1

I STAN B U L

0 5 /0 4 /2 0 0 8

RECORD2

ADANA__

1 1 /0 4 /2 0 0 8

RECORD3

BITLIS__

1 6 /0 4 /2 0 0 8

RECORD4

HATAY_ _

2 9 /0 4 /2 0 0 8

RECORD5

EDIRNE_

You may view any saved record by selecting it


through up/down keys and press OK key.

ARCHIVES SCREEN

There are two tabs in the archive menu. These are the 3D RESULT tab and
the CAMERA tab. Using the right/left direction keys, you can
select one of these tabs and you can access the CAMERA or the
3D RESULT records when you press the OK key.

After selecting one of the records using the up/down direction keys and by
pressing the OK key, you can watch the video that you have recorded.
Please use the BACK key in order to exit this window. Please use the
DEL key in order to delete any of the entries after selecting it with the
up/down direction keys.

10

Starting

Use of Additional Features


3D
RESULT

3D RESULT: You can view the 3D result screens you have


previously saved in the Golden King Deep Processor Radar
system. To view the 3D result screens, please press the
SAVE key on the keypad. Using the right/left direction
keys, you can select the 3D RESULT tab and press the
OK key.

DATE

NAME

REGION

0 2 /0 4 /2 0 0 8

3D R E C O R D 1

I STAN B U L

0 5 /0 4 /2 0 0 8

3D R E C O R D 2

ADANA__

1 1 /0 4 /2 0 0 8

3D R E C O R D 3

BITLIS__

1 6 /0 4 /2 0 0 8

3D R E C O R D 4

HATAY_ _

2 9 /0 4 /2 0 0 8

3D R E C O R D 5

EDIRNE_

Using the Camera Recorder


The Golden King Deep Processor Radar system is equipped with a special
camera recorder with night vision that can be used 30 meters under water, is
resistant up to 4 bars of pressure and that can record at a high display quality.
The camera recorder can also operate on land with the same display quality.
During your search in difficult areas such as wells and caves filled with water,
lakes, sea, brooks, water-filled cisterns and tunnels, you will get clear images
due to your high quality camera recorder. Also on land, you will conveniently
view the inside of tunnels, caves and cisterns without having to enter them.
?
Pick-up Device:1/4" 1/3" SONY Super HAD CCD
?
Picture Element: PAL:500(h)X582(v)
?
NTSC: 510(H)X492(V)
?
TV Systems: PAL / NTSC
?
Horizontal Resolution: 480-420 TV lines
?
Minimun Illumination: IR or 0 Lux
?
S/N Ratio: More than 48dB
?
Gamma Characteristic: 0,45
?
Back Light Compensation: Auto
?
Synchronous System: Internal Synchronization
?
Lens Mount: Board lens: 3,6/6/8/12mm
?
Video Output: 1,0Vp-p,75W,BNC Connector
?
Infrared Lamps irradiation distance: 15m
?
Auto White Balance: Auto
?
Auto Gain control:Auto

You may view any saved record by selecting it


through up/down keys and press OK key.

After selecting one of the records using the up/down direction keys, press
the OK key to view the 3D result screen. Please use the BACK key
in order to exit this window. Please use the DEL key in order to delete
any of the entries after selecting it by the up/down direction keys.

Use
The camera recorder with its 30m cable comes with your device,ready
for use. After you remove the camera recorder from its bag, insert the
socket at the end of the cable into the camera recorders input jack. Then,
press the camera recorder key located on the keypad. Within seconds,
your system will sense the camera recorder and transfer the image to the
monitor. After this step, your camera recorder is ready to operate.

11

Use of Additional Features


After the cameras socket is inserted into the camera recorders input
jack, press the camera key on the keypad. Approximately within 15-20
seconds, the interface below will come up. Here the camera is in the
preview mode and it will show the current view.

PLEASE ENTER DATE / NAME / REGION


INFO BY USING LETTERS AND NUMBERS
ON THE KEYPAD.
DATE

PLAY

_ _ /_ _ /_ _ _ _

NAME
_________

REGION
_________

AFTER COMPLETION OF NAMING,


PRESS OK KEY.
REC

After entering the date, name and the region information and pressing the
OK key, the recording starts. In order to stop the recording, you can use
the STOP button. You can use the BACK key in order to quit without
recording and to return to the preview mode.

REC

REC BUTTON

When the REC button is pressed, the camera is switched from the preview
mode to the record mode. By selecting the REC button with the up/down
direction keys and by pressing the OK key, the record window below will
appear on the screen.

PLAY

PLAY BUTTON

In order to watch the videos you have recorded please select the PLAY
button with the up/down direction keys and press the OK button. When
you press the PLAYbutton all the videos you have recorded will appear
on the screen.

12

Use of Additional Features

PAUSE
PAUSE

STOP

DATE

NAME

PAUSE BUTTON

REGION

0 2 /0 4 /2 0 0 8

RECORD1

I STAN B U L

0 5 /0 4 /2 0 0 8

RECORD2

ADANA__

1 1 /0 4 /2 0 0 8

RECORD3

BITLIS__

1 6 /0 4 /2 0 0 8

RECORD4

HATAY_ _

2 9 /0 4 /2 0 0 8

RECORD5

EDIRNE_

When viewing the saved videos, you can pause any moment
of the video indefinitely by using the PAUSE button. This way,
you can view the videos you have recorded in more detail. By pressing
the PAUSE button again, you can continue watching the video.

You may view any saved record by selecting it


through up/down keys and press OK key.
PAUSE

The user can select the desired video with the up/down direction keys.
Then, the video can be watched by pressing the OK key.

STOP

PAUSE Pausing the video

13

Use of Additional Features

X BUTTON

X BUTTON
If slower viewing is needed, press the X button to watch the video
recorded on 30 fps as 7 fps.
The video will now play at 1/4 of the normal speed.

When viewing the videos you have recorded, your system is designed to
display 30 frames per second (fps). This frame speed is the standard video
format. When you want to watch the video in slow motion, the system offers
two alternatives to the user. First is the X button. With the up/down
direction keys, select the X button and activate it with the OK
key. The video will now play at half of the normal speed.
PAUSE

STOP
PAUSE

X
STOP

X
X

Slow motion of the video at of the


normal speed

Slow motion of the video at of the


normal speed

14

Use of Additional Features

Gas Sensor
The Golden King Deep Processor Radar system is equipped with a gas
sensor which measures and informs the user of the presence of methane gas
which is one of the flammable, explosive and toxic gases in confined places.

You can reach the video recordings of the regions you


have previously searched through the ARCHIVES
screen.
You can also obtain the signal map of the regions you
have searched by the archive feature of the system.
You can access all this information when needed.

The connector of the gas sensor is inserted into the gas sensor input on the
system box. Then,the gas sensor key on the keypad is pressed.
The gas sensor menu appears on the screen.

Gas sensor key

GAS SENSOR

Gas sensor menu

15

Use of Additional Features

After measuring, the user is warned by one of the two results:


First one is: SAFE METHANE LEVEL THERE MAY BE DIFFERENT
GASES, WEAR GAS MASK FOR YOUR SAFETY

The gas sensor socket input is shown in the picture below.

SAFE METHANE LEVEL


THERE MAY BE DIFFERENT
GASES, WEAR GAS MASK
FOR YOUR SAFETY

Gas sensor
socket input

GAS SENSOR

The other one is METHANE GAS LEVEL IS HIGH EXPLOSION AND


COMBUSTION DANGER; DO NOT ENTER
The gas sensor measures the methane gas level in the confined space within
an average of 5 minutes after arrival at the site and informs the user of the
result. The system starts to count down and shows the remaining time for
measuring on the screen to the user.

Remaining time for measuring result of gas detector

02:20

METHANE GAS LEVEL IS


HIGHEXPLOSION AND
COMBUSTION DANGER;
DO NOT ENTER

GAS SENSOR

GAS SENSOR
Press BACK to exit the gas sensor menu.

16

Use of Additional Features


Headphones

Use of the Search Coil


When designing the Golden King Deep Processor Radar, it was our first and
one of the most important goals to consider all the needs of the user on the
field and to provide the best results while fulfilling these needs.

Frequency range 20 ~ 20,000Hz


Impedance 32 ohm
Sensitivity 105dB 3dB(at 1kHz)
Maximum input power 100mW
Jack 3.5mm Stereo
Cable 2.5m%10

Therefore, we have developed the SMART SEARCH COIL system. These


detection heads will not only give the most accurate information to you, but
they will also check all your moves and acts which may adversely affect the
data during your search. The adverse effects of such acts on the result are
taken into consideration and the effects are minimized.
The SMART SEARCH COIL system manages and delivers all the
information - height, depth etc. - that the user needs.

The Golden King Deep Processor Radar system is equipped with


multi-functional, ergonomically designed, stereo headphones . During your
search on the field, you will easily hear all the audio-related functions of the
system. At the same time, you will be able to search in silence by avoiding the
external noises.
You can set the audio level as you need with the volume buttons which
control each headphone individually.

Volume button

There is a different search coil for every need. The Golden King Deep
Processor Radar provides you with three types of search coils. You will be
able to attach these search coils within seconds with the provided connectors
when needed.
SMART DETECTION is one of the features which makes the Golden King
Deep Processor Radar unique worlwide. When you turn on the SMART
DETECTION system, it gets activated right away and it observes all your
moves until the completion of your search. Due to the high display
technology it uses, the user can view his/her moves in real time on the monitor.

17

Use of Additional Features


Surface Search Coil (210x315mm)
This search coil which is very sensitive to small objects and to those that are
close to the surface, is capable of getting results up to 3 meters depth. It is
very ideal for single coin searches and it is very sensitive to small
metals on the surface like no other searh coil is.
You can, if you like, switch off the FERROUS mode on your system
and search whill avoiding any undesired ferrous metal (beverage bottle caps,
nails, wires or cans, etc.). The surface search coil has also high capability of
metal discrimination. No matter how small the target is, you will not miss it.

General Search Coil (360x440mm)


This search coil which has been very efficient in detecting targets up to 5
meters depth is designed to get the most accurate results both in deep places
and at the surface.
Due to its superior metal discrimination, excellent target detection and
its capability of searching whill avoiding ferrous metals, your searches
will be very pleasant.

The Smart Search Coils and the entire Golden King Deep Processor Radar
system have been developed after comprehensive R&D activities, both
electronical and chemical. Thermoset engineering plastic is used on the
entire system and on the Search Coils. They are developed perfectly to resist
the bad weather conditions such as hot, cold and humid as well as water and
moist.

18

Use of Additional Features


Deep Search Coil 600x1000mm
As you will not be able to use the RESET and the CONFIRM buttons on
the joystick once you connect this search coil, the buttons on the search
coil carrying hangers are used for performing the reset and the confirm
functions.The green button is used for the CONFIRM function and blue
button is used for the RESET function.
The Deep Search Coil is controlled by an exclusive software program which
enables the device to examine very deep target signals at a very high
resolution. With the deep search coil that is 100x60cm in size, you will be able
to get good results at up to 8 meters depth. The deep search coil has also
metal discrimination capability.
Reset

Ways and Speed of Detection


Usage speed during detection
Fast detections: 3.913 m/hour.
Normal Detections: 1.200 m/hour
Slow Detections: 664 m/hour
With the Golden King Deep Processor Radar system, you can search with or
without swaying the search coil.

Confirm

Deep search coil


carrying hangers

19

Ground Balance

AUTOMATIC GROUND BALANCE

Ground Balance
On the Golden King Deep Processor Radar system, ground balancing is done
through the GROUND BALANCE menu. You can access the ground
balance menu both from the settings section or by pressing the
GROUND BALANCE key on the keypad.

OK

What you need to do is to eliminate the soil in the box on the left side of the
screen and turn it to green and save it by pressing the OK button.
Method:
AUTOMATIC

MANUEL

GROUND SETTING
When GROUND BALANCE is selected, you will see two tabs. These tabs are
AUTOMATIC and MANUAL ground balance tabs. You may switch from one
tab to another with the right/left direction keys. You can select the one you want
by pressing the OK key. The option you select will turn to red.

Before doing automatic ground balancing, hold the search coil


about 10 centimeters above the ground and press OK.
With this operation, your equipment will take the ground as a
reference.
10cm

What you should do next is to raise the search coil about 40 centimeters
above the ground and press the RESET button.

AUTOMATIC GROUND BALANCE


MAXIMUM UPPER LEVEL

AUTOMATIC GROUND BALANCE

RESET
40cm
Reset Button

When the AUTOMATIC GROUND BALANCE is selected, you will see the
interface on the top right of the page.

40cm

20

Ground Balance
After pressing the RESET button, following the animated guide on the screen,
hold your search coil about 10cm above the ground again and press the
CONFIRM button. Please wait until the clock on the screen makes one
complete turn after pressing the CONFIRM button.

AUTOMATIC GROUND BALANCE


MAXIMUM LOWER LEVEL

Please continue these steps until the box with the soil on the left side
completely turns to green. The soil in the box will decrease each time you
follow these steps depending on the mineral composition of the ground.
The ground balance will be completed as soon as the box completely turns to
green. You can switch to the search screen by pressing the OK button.

GROUND
NOT SET

DECREASING
EFFECT

DECREASING
EFFECT

DECREASING
EFFECT

GROUND
SET

CONFIRM
10cm

10cm

What you should do now is to raise the search coil to 40cm above
the ground again. When you press the RESET button, the animated guide
will lower the search coil down to 10cm above the ground again and so should
you. Each time you lower your search coil to the ground and press the
CONFIRM button, the box with the soil on the left side of the screen will
start turning to green.These steps should continue until the box completely
turns to green as shown on the right side. When the box is completely green,
it means that the ground balancing has been completed succesfully.

Confirm Button

Reset Button

AUTOMATIC GROUND BALANCE


MAXIMUM UPPER LEVEL

RESET
40cm

The system will switch to the general detection mode when you press the
OKbutton. The system will not switch to any screen until you press the
OK button.

40cm

21

Ground Balance

Raise the search coil 40cm above the ground and press the - / + key on the
keypad for an estimated number of times to eliminate the effect.
Because the effect is in the positive direction in the example below, you should
press the + key. If the incoming effect was negative, then you would press
the - key.

MANUAL GROUND BALANCE

When MANUAL GROUND BALANCE is selected, you will see the


interface below.

NEGATIVE

POSITIVE

MANUAL GROUND BALANCE


NEGATIVE

40cm

POSITIVE

Now press the RESET button, release and lower the search coil to 10cm
above the ground again.

NEGATIVE

On this screen, there is a level indicator that can receive the effect of the
ground in both directions, - Negative and + Positive. When you hold the
search coil above the ground for the first time, the system is affected from the
mineral level of the ground in the negative or the positive direction.
The purpose is to eliminate this effect coming from the ground.
Method: Detection coil is held 10cm. above the ground. Let's say that we
we have received an effect from the ground in the positive +direction.

NEGATF

POSITIVE

10cm

You see that the effect coming from the ground is less now. Repeat these
steps until you receive no effect from the ground. When the effect is completely
eliminated, save the ground setting by pressing the OK button.

When finished, do not forget to save the ground balance setting by


pressing the OK button. When you press the OK key, the system will
switch to the general detection mode. If you do not press the OK button,
the system will not switch to another screen until you press the OK button.

POZTF

10cm

22

Ground Balance

Detection Functions

RESET BUTTON

Interface Selection
The Golden King Deep Processor Radar system offers two types of detection
interfaces. First one is DIGITAL and the second one is GAUGE interface.
The user can search by selecting the interface which he/she will use most
conveniently. These interfaces can be changed anytime through the interface
selection menu.
RESET BUTTON

The reset button will bring all the detection settings of your system to the
settings when you made the ground balance. Reset should not be used when
you are on the target signal. Otherwise, it may cause loss of depth and
misinterpretation of the signal.
The reset operation should be performed when the coil is away from the
target. You are recommended to reset after each operation.
Note:
When ground balance cannot be performed completely due to high levels
of minerals, return to the SENSITIVITY menu and reduce the sensitivity
level. Continue this operation until you can do the ground balance
completely.
Note:
Ground balance should be performed on a ground where there is no
metal or cavity. Otherwise, the equipment will detect that you are on a
metal or cavity and will warn you accordingly. In such a case, change your
location and do it again.

GOLDEN

68
METAL

DIGITAL

30
MINERAL

GAUGE

INTERFACE SELECTION

You can select the interface you want from the menu above with the
right/left direction keys. You can save the interface you have selected by
pressing theOK button.

23

Detection Functions
DIGITAL DETECTION

Nokta
ENGINEERING

GENERAL DETECTION
YOU DETECTED A TARGET!
PLEASE HOLD CONFIRM BUTTON AND PASS
OVER THE TARGET TO GET ALL INFORMATION
ABOUT THE TARGET.

SCOPE SCREEN
With the Golden King Deep Processor Radar, you will easily follow
the amplitude of the target signal in real time on the SCOPE Screen.
On this screen, you will both see the highest amplitude point of the signal
center in real time and examine the signal graphs of both the cavities and the
metal targets.

The digital detection interface named as General Detection consists of the parts
and sections below and on the right side. Now we will explain these sections
which will give you the initial data about the target signal during your searches.

SMART DETECTION COILS


Due to the Smart Detection Coils
used in the Golden King Deep
Processor Radar, you can view
your moves as well as the detected
target on the interactive search screen.

RADAR SCREEN
Another new feature of the Golden King Deep Processor Radar is the
RADAR SCREEN. Due to this screen, while the user is following the operation
of the system, he/she will also have information about the target based on the
color changes of the RADAR SCREEN when a metal / a cavity
(negative/positive) signal is detected. The RADAR SCREEN turns to red in
case of a positive (metal) signal. In case of a negative (cavity) signal,
it turns to blue. This way the user is given initial data about the target which
enables the user to search more quickly.

24

Detection Functions
YOU DETECTED A TARGET !
PLEASE HOLD CONFIRM BUTTON AND PASS
OVER THE TARGET TO GET ALL INFORMATION
ABOUT THE TARGET.

GOLD

73
CAVITY

21
MINERAL

68
METAL

min

30

max

23

MINERAL

YOU DETECTED A TARGET !


PLEASE HOLD CONFIRM BUTTON AND PASS
OVER THE TARGET TO GET ALL INFORMATION
ABOUT THE TARGET.

REPORT SCREEN
The Golden King Deep Processor Radar communicates the initial data
received from the target signal and the following steps to be performed
through the REPORT SCREENS. The report screen not only gives information
about the target signal, but it also guides the user regarding the system
warnings as well as the following steps to be performed.
Like a private guide always at your side, the REPORT SCREEN will be a
partner working together with you throughout your searches and detections,
giving you all the information you need and checking all your actions for
accuracy.

GOLD

68
METAL
GOLD

68
METAL

GAUGE DETECTION
30

MINERAL

The Gauge option on the Golden King Deep Processor Radar system has
been designed as a convenient detection interface, considering the users old
habits about the former systems. All sections present in the general detection
(DIGITAL DETECTION) are available here but represented by a gauge system
instead.

30
MINERAL

METAL SECTION GAUGE


During your search, you will be able to follow all the data and information
received from the target signal by the GAUGE DETECTION on this screen
such as whether the metal is ferrous or non- ferrous, whether it is alloy or
gold etc. You will follow all the information through the digital gauge on the
screen and see the metal-mineral ratios in numbers. Again, you will be able
to determine whether the signal received from the target underground is alloy
or not.

25

Detection Functions
YOU DETECTED A TARGET!
PLEASE HOLD CONFIRM BUTTON AND PASS
OVER THE TARGET TO GET ALL INFORMATION
ABOUT THE TARGET.

73
CAVITY

21
MINERAL

CAVITY SECTION GAUGE


It is the section of the GAUGE DETECTION interface which gives cavity
data. In this section, you will follow the target signals and read them in
percentage figures. Due to the gauges, you will see and examine the status of
the signal received from the target in real time. You will see the cavity and the
mineral ratios in numbers.

REPORT SCREEN
Searching with the gauge screen of the Golden King Deep
Processor Radar is very clear and pleasant. While you see the clear
information received from the target signal on the report screen, you will also
be informed about the following steps to be performed.

ALTIN

min

max

23
SCOPE SCREEN
During your searches with the Golden King Deep Processor Radar, you will
easily follow the amplitude of the the target signal in real time on the
SCOPE Screen. On this screen, you will determine the highest amplitude
point of the signal center in real time and examine the signal graph of both the
cavity and the metal targets. Unlike the general detection, you can observe the
highest point of the target signal when you use the gauge detection.
The highest point that the pointer reaches represents the center of the target
signal.

73
CAVITY

21
MINERAL

68
METAL

30
MINERAL

min

max

23
YOU DETECTED A TARGET!
PLEASE HOLD CONFIRM BUTTON AND PASS
OVER THE TARGET TO GET ALL INFORMATION
ABOUT THE TARGET.

26

Technical Characteristics

Result Screen
Result Screen
You can examine the 3D graph of the target signal on the result screen of
the Golden King Deep Processor Radar in real time. On the result screen, there
are 3 graph windows. 1st window is the top view of the signal, 2nd window is
the side view of the signal and the 3rd window is the perspective view of the
signal.
On the vertical guide scale to the left of the 3D perspective image, you can see
the amplitude of the target signal. Again on the horizontal guide scale to the left,
you can see the width of the scan area. On the horizontal scale located at the
bottom part, you can see the length of the scan area.
Again by referring to these guide scales, you can see the estimated width and
length of the signal. From the report section on the right side of the result
screen, you can get information about the signal. In order to view the
3D graph in full screen please press the 1 key on the keypad. After switching
to the full screen mode, you can use the 2, 3 and4 keys to view the 3D
graph from different angles. When you press the BACK key, the system will
return to the search screen automatically.

RESULT SCREEN

TARGET SIGNAL
NONFERROUS METAL
GOLD
CAVITY SIGNAL IS RECEIVED
ALONG WITH METAL SIGNAL
TARGET SIGNAL
STARTING DEPTH
100CM
TO EXAMINE
SIGNAL ON FULL DISPLAY
YOU MAY USE 1 KEY,
TO VIEW AT DIFFERENT
ANGLES YOU MAY USE
THE KEYS 1 2 3 ON
THE NUMERATOR

METAL
MINERAL
METALLIC
DIFFUSION

YOU MAY SAVE THIS SCREEN BY


PRESSING SAVE KEY
FOR EXIT PRESS BACK

CAVITY

Detection Coil

210 x 315

360 X 440

600 X 1000

Frequency

12.5 kHz

12.5 kHz

12.5 kHz

TFT

TFT

TFT

5x5

60 cm

85 cm

80 cm

10 x 10

80 cm

110 cm

120 cm

20 x 20

115 cm

140 cm

160 cm

30 x 30

140 cm

182 cm

215 cm

40 x 40

155 cm

220 cm

245 cm

60 x 60

185 cm

270 cm

305 cm

80 x 80

225 cm

295 cm

350 cm

100 x 100

245 cm

335 cm

410 cm

Screen
WIDTH (cm)

These numbers are obtained in a lab environment. They may


differ depending on the composition of the ground

27

Menu Description

LANGUAGE SELECTION

LANGUAGE SELECTION MENU:


It consists of 10 languages:
Turkish, English, Greek, Persian,
Bulgarian, Arabic, French, Spanish,
German and Russian. Once the user
selects a language, the whole system
switches to that language instantly.

OPERATING MANUAL

OPERATING MANUAL MENU:


The operating manual is full of information
that you can refer to anytime you want. It
consists of Warnings, Correct trial,
Incorrect trial and Useful information.
You may find all kinds of information about
the use of the equipment in this menu.

+100

VOLUME MENU

VOLUME MENU:
To set the audio volume of the system, use
the volume control consisting of 10
levels in the volume menu. In this menu,
you can increase and decrease the volume
as you wish.

+100
BRIGHTNESS MENU:
In this menu, you can adjust the brightness
of the screen. You can increase or
decrease the brightness as you wish.
BRIGHTNESS SETTING

+100

SENSITIVITY MENU:
It is for setting the depth of the system to
your need. Especially when ground balance
is hard to achieve due to high levels of
minerals in the ground, reduce the sensitivity
and do the ground balancing again.

SENSITIVITY SETTING

ON

OFF

FERROUS SETTING

FERROUS SETTING MENU:


The system allows you to search while
avoiding ferrous metals (nails, irons, bottle
caps, etc.) if you like. You can switch the
on/off ferrous feature in the ferrous setting
menu.

28

Menu Descriptions

GOLD

68
METAL

DIGITAL

30
MINERAL

GAUGE

INTERFACE SELECTION

AUTOMATIC

MANUEL

GROUND BALANCE

GAS SENSOR

INTERFACE SELECTION MENU:


Interface selection consists of 2
alternatives to provide you with a more
convenient use during your search. You
can select the one you want by using the
right/left direction keys and save it by
pressing OK.

GROUND BALANCE MENU:


The system provides the user with two
alternatives to do ground balancing.
These are AUTOMATIC and MANUAL
ground balances. Ground balance is one of
the most important functions of the system.
The accuracy of the results you will get
depends on a good ground balance.

GAS SENSOR MENU:


A gas sensor is incorporated with the
system to ensure your safety before
entering any confined space. This sensor
detects methane -a flammable and
explosive gas present in confined areasand warns the user.

CAMERA

101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101
101010101001010101

CAMERA

3D
RESULT

ARCHIVES SCREEN

SIGNS

CAMERA RECORDER MENU:


On the system, a camera recording
system is used which can take shots
at a high display quality both on land
and under water. It can easily be used at
up to 30m depth and is resistant up to
4 bars of pressure. Due to its night vision
feature, it allows you to take shots easily
even in pitch dark environments.

SAVE SCREEN MENU:


The system saves both the 3D result
screen information and the videos you have
recorded. It enables you to access them
anytime you want.

SIGNS MENU:
The signs menu contains the meanings of
hundreds of signs you may come across
on site during your search. There are
406 symbols and signs, together with
their meanings, present in the system.

29

Exemplary Use

In this presentation, we have explained everything about the operation


of the equipment from start up to finding the target signal with
graphics and texts. You can practice searching by following this
presentation.
We, as Nokta Engineering, have focused on the ease of use for
this system. Your searches and detections with the GOLDEN KING
DEEP PROCESSOR RADAR which incorporates everything you
have dreamed about will become an extraordinary pleasure.
We wish you success in all your searches and detections.

WARNING

PLEASE PRESS THE ON BUTTON ON THE


BATTERY AT THE BACK OF THE SYSTEM
BOX IN ORDER TO TURN ON THE SYSTEM.

THE GOLDEN KING NEW GENERATION RADAR


SYSTEMS have higher depth compared to other
detector systems. Please pay attention to not holding
the detection coils too close to the system box.
Please keep your system box to the side of your body
by the help of the carrying case so that the detector
will not be affected. Do not let the search coil come
close to your shoes, belt, watch or any other metal
object you are carrying.

LANGUAGE SELECTION

PLEASE SELECT THE LANGUAGE YOU WANT


BY USING THE RIGHT-LEFT DIRECTION KEYS
AND CONFIRM BY PRESSING OK. TO EXIT
THE MENU PRESS BACK.

30

4
+100

BRIGHTNESS SETTING

PLEASE SET THE VOLUME OF YOUR SYSTEM


BY USING THE RIGHT-LEFT DIRECTION KEYS.
TO EXIT THE MENU, PRESS THE BACK KEY.

PLEASE SET THE BRIGHTNESS OF THE


SCREEN. TO EXIT THE MENU, PRESS THE
BACK KEY.

FERROUS SETTING

PLEASE SET THE SENSITIVITY LEVEL.


THE RECOMMENDED SENSITIVITY LEVEL IS
+80 UNTIL YOU GET ACCUSTOMED TO THE
EQUIPMENT. SET THE LEVEL BY USING THE
RIGHT/LEFT DIRECTION KEYS. TO EXIT THE
MENU, PRESS THE BACK KEY.

PLEASE MAKE THE FERROUS SETTING BY SELECTING


THE ON OR OFF TAB. IF YOU SELECT THE OFF
TAB, YOU CAN SEARCH WHILE AVOIDING FERROUS
METALS. YOU CAN MAKE YOUR SELECTION BY USING
THE RIGHT/LEFT DIRECTION KEYS. TO EXIT THE
MENU, PRESS THE BACK KEY.

31

GROUND BALANCE

PLEASE SELECT EITHER THE AUTOMATIC OR


THE MANUAL GROUND BALANCE USING
THE RIGHT/LEFT DIRECTION KEYS. TO EXIT
THE MENU, PRESS THE BACK KEY.

PLEASE SELECT THE DETECTION SCREEN


USING THE RIGHT/LEFT DIRECTION KEYS.
TO EXIT THE MENU, PRESS THE BACK KEY.

10

AUTOMATIC GROUND BALANCE

AUTOMATIC GROUND BALANCE

MAKSMUMUPPER
ST SEVYE
MAXIMUM
LEVEL

MAKSMUM
ST SEVYE
MXIMUM
LOWER
LEVEL

40cm

Reset Button

OK
10CM

10cm

PLEASE HOLD THE SEARCH COIL 10cm.


ABOVE THE GROUND. PRESS OK TO
TAKE THE GROUND AS A REFERENCE.

RESET
40cm

40CM

PLEASE RAISE THE SEARCH COIL TO 40CM ABOVE


THE GROUND AND PRESS THE RESET BUTTON.

32

12

11
Confirm Button

AUTOMATIC GROUND BALANCE

AUTOMATIC GROUND BALANCE

MAXIMUM LOWER LEVEL

MAXIMUM
UPPER
LEVEL
MAKSMUM
ST SEVYE

Reset Button
CONFIRM
10cm

RESET
40cm

40cm

10cm

NOW LOWER THE DETECTION COIL TO 10cm


ABOVE THE GROUND AS SHOWN IN THE
ANIMATION. AFTER PRESSING THE CONFIRM
BUTTON WAIT UNTIL THE COUNTER
COMPLETES A FULL TURN.

PLEASE RAISE YOUR SEARCH COIL TO 40cm


ABOVE THE GROUND AGAIN AND PRESS THE
RESET BUTTON.

13

14
Confirm Button

AUTOMATIC GROUND BALANCE

AUTOMATIC GROUND BALANCE

MAXIMUM LOWER LEVEL

MAKSMUM
ST SEVYE
MAXIMUM
UPPER
LEVEL

Reset Button
CONFIRM
10cm

10cm

AFTER HOLDING THE SEARCH COIL 10cm ABOVE


THE GROUND, PLEASE PRESS THE CONFIRM
BUTTON AND WAIT UNTIL THE COUNTER COMPLETES
A FULL TURN. WHEN YOU LOWER YOUR SEARCH COIL
TO THE GROUND EACH TIME, THE BOX FILLED WITH
SOIL ON THE LEFT SIDE OF THE SCREEN WILL TURN
TO GREEN.

RESET
40cm

40cm

RAISE YOUR SEARCH COIL TO 40cm ABOVE


THE GROUND AND PRESS THE RESET
BUTTON. AFTER PRESSING THE RESET
BUTTON, PLEASE LOWER THE SEARCH COIL
TO 10cm ABOVE THE GROUND AND PRESS THE
CONFIRM BUTTON.

33

15

16
Confirm Button

AUTOMATIC GROUND BALANCE


MAXIMUM LOWER LEVEL

CONFIRM
10cm

WHEN THE BOX COMPLETELY TURNS TO GREEN,


IT MEANS THAT THE GROUND BALANCE IS COMPLETED
SUCCESFULLY. AFTER THE GROUND BALANCE IS
COMPLETED, A MESSAGE INDICATING THE START
AND THE END SENSITIVITY LEVELS APPEARS ON THE
SCREEN. NOW YOU CAN START SEARCHING BY PRESSING
THE OK BUTTON. THE SEARCH DISTANCE FROM THE
GROUND SHOULD BE 15-20cm (ABOUT 1 HAND DISTANCE).

17

WHEN A TARGET IS DETECTED PLEASE


DETERMINE THE CENTER OF THE TARGET BY
THE SCOPE SCREEN AND PRESS THE OK KEY
ON THE KEYPAD. THEN MOVE THE SEARCH COIL
AWAY FROM THE TARGET AND PRESS AND
RELEASE THE RESET BUTTON.

18
Confirm Button

Confirm Button

WHEN YOU DETECT A TARGET AND THE TARGET


IS METAL, THE RADAR WINDOW WILL TURN TO
RED. TO GET ALL THE INFORMATION ABOUT THE
TARGET, PLEASE PRESS AND HOLD THE CONFIRM
BUTTON AND PASS OVER THE TARGET. TO EXIT
THE MENU, PRESS THE BACK KEY.

PASS OVER THE TARGET BY PRESSING AND


HOLDING THE CONFIRM BUTTON. AFTER
PASSING OVER IT, RELEASE THE CONFIRM
BUTTON. TO EXIT THE MENU, PRESS THE BACK
KEY.

34

19

20
Confirm Button

Confirm Button

YOU DETECTED A TARGET!

YOU DETECTED A TARGET!


PLEASE HOLD CONFIRM BUTTON AND PASS
OVER THE TARGET TO GET ALL INFORMATION
ABOUT THE TARGET.

Reset Button

Reset Button

PLEASE HOLD CONFIRM BUTTON AND PASS


OVER THE TARGET TO GET ALL INFORMATION
ABOUT THE TARGET.

TO CHANGE YOUR DIRECTION, PRESS THE


RESET ONCE. HOLD THE CONFIRM BUTTON
PRESSED AND PASS OVER THE TARGET FOR
THE LAST TIME. TO EXIT THE MENU, PRESS THE
BACK KEY.

PRESS THE RESETBUTTON ONCE AND PASS


OVER THE TARGET IN THE OPPOSITE DIRECTION
AGAIN BY HOLDING THE CONFIRM BUTTON
PRESSED. TO EXIT THE MENU, PRESS THE BACK
KEY.

21

22
Confirm Button

YOU DETECTED A TARGET!


PLEASE HOLD CONFIRM BUTTON AND PASS
OVER THE TARGET TO GET ALL INFORMATION
ABOUT THE TARGET.

RELEASE THE CONFIRM BUTTON. THE


SYSTEM WILL AUTOMATICALLY SWITCH TO THE
RESULT SCREEN. TO EXIT THE MENU, PRESS
THEBACK KEY.

YOU CAN VIEW ALL THE INFORMATION ABOUT THE


TARGET SIGNAL, INCLUDING DEPTH, ON THE RESULT
SCREEN. YOU CAN RETURN TO THE SEARCH
SCREEN BY PRESSING THE BACK KEY.

35

23

24
IF YOU DESIRE TO SAVE 3D RESULT
SCREEN, PRESS SAVE KEY ON THE
KEYPAD.
DATE
_ _ /_ _ /_ _ _ _

NAME
_________

REGION
_________

TO EXIT WITHOUT SAVING, PLEASE


PRESS BACK KEY.

YOU CAN VIEW THE TARGET SIGNAL ON FULL


SCREEN BY PRESSING THE 1 KEY ON THE
KEYPAD AND YOU CAN ROTATE AND EXAMINE THE
SIGNAL BY USING THE 2 - 3 - 4 KEYS. YOU CAN
EXIT THE MENU BY PRESSING BACK. YOU CAN
SAVE THE RESULT SCREEN BY HOLDING THE
SAVE KEY PRESSED.

WHEN YOU PRESS THE SAVE KEY, THE SAVE


WINDOW ON THE RESULT SCREEN WILL COME
UP. ENTER THE DATE/NAME AND REGION
INFORMATION BY USING THE KEYPAD.

25

26
PLEASE ENTER DATE / NAME / REGION
INFO BY USING LETTERS AND NUMBERS
ON THE KEYPAD.

PLEASE ENTER DATE / NAME / REGION


INFO BY USING LETTERS AND NUMBERS
ON THE KEYPAD.
DATE
_ _ /_ _ /_ _ _ _

NAME
000000001

REGION

DATE

_________

1 1 /0 1 /2 0 0 8

AFTER COMPLETION OF NAMING,


PRESS OK KEY.

WHEN NO DATA IS ENTERED, THE EQUIPMENT


WILL SAVE THE OPERATION WITH A NUMBER
IT WILL ASSIGN AUTOMATICALLY.

NAME
VIDEO 1

REGION
HAKKARI__

TO EXIT WITHOUT SAVING, PLEASE


PRESS BACK KEY.

AFTER SAVING THE INFORMATION, PRESS THE


OK KEY ON THE KEYPAD TO COMPLETE THE
SAVING OPERATION. TO EXIT WITHOUT SAVING,
PRESS THE BACK KEY.

36

ATTENTION!
The Golden King Deep Processor Radar is the best system produced so far among the systems that receive data from underground.
The detector and radar systems delivering 100% performance on land or in the sea do not operate with 100% accuracy underground.
Scientifically, it is not possible to get 100% accurate results.
With respect to the results it gives, the Golden King Deep Processor Radar is the ultimate point in technology.
Results on all these systems may vary depending on the use, weather conditions, mineral levels in the ground and the environmental effects.
Our company is not responsible for any of the above affecting the performance of the Golden King Deep Processor Radar.
On the Golden King Deep Processor Radar, the interpretations of the detections made by our system are the best interpretations allowed by the current
technology. These interpretations are for assisting the user. These results are not definite. They are accurate to the extent technologically feasible.
Data and the depth values given in the technical manual of the Golden King Deep Processor Radar system are obtained at a laboratory.
This data may vary on the search field. Metals do not emit magnetic field by themselves unless they are excited. Metals buried in the ground come into a
chemical reaction, which we also refer to as rusting, with the minerals and the metal compounds in the soil. As a result of this reaction, an electrolysis flow
occurs between the metal and the soil and the metal becomes subject to corrosion, forming a composition with the minerals or the metals of the ground.
And this phenomenon positively affects the detection distance for the detectors.
The pH value of the soil and the mineral it contains as well as the rich metal structure are factors leading to fast or slow reaction. For this reason, big metals
at depths which normally cannot be detected may be detected by the GOLDEN KING DEEP PROCESSOR RADAR at depths up to 8m provided that
the above-mentioned conditions are present.
Nokta Engineering

You might also like