0% found this document useful (0 votes)
51 views6 pages

Sistem Besprekidnog Napajanja Za Industrijske Uslove Rada: Beograd 2015. Godine

This document provides an overview of an uninterruptible power supply (UPS) system intended for industrial applications. The UPS system consists of three main components - a rectifier, inverter, and static switch - housed in a single cabinet. The rectifier converts alternating current to direct current to charge the battery and power the inverter. The inverter then converts the direct current back to alternating current to power loads connected to the UPS. The static switch seamlessly transfers the load between the inverter and external power source without an interruption in power. The system provides clean, stable power to loads and protects them from issues like voltage fluctuations, outages, overvoltages and more.

Uploaded by

jandaz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
51 views6 pages

Sistem Besprekidnog Napajanja Za Industrijske Uslove Rada: Beograd 2015. Godine

This document provides an overview of an uninterruptible power supply (UPS) system intended for industrial applications. The UPS system consists of three main components - a rectifier, inverter, and static switch - housed in a single cabinet. The rectifier converts alternating current to direct current to charge the battery and power the inverter. The inverter then converts the direct current back to alternating current to power loads connected to the UPS. The static switch seamlessly transfers the load between the inverter and external power source without an interruption in power. The system provides clean, stable power to loads and protects them from issues like voltage fluctuations, outages, overvoltages and more.

Uploaded by

jandaz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

RIS31120

Sistembesprekidnognapajanjazaindustrijskeusloverada

Beograd2015.godine

Elektrotehnikiinstitut"NikolaTesla"
Centarzaauotmatikuiregulaciju
KosteGlavinia8a,11000Beograd,
tel.+381113952042email:info
@ieent.org

web:www.ieent.org

ElectricalEngineeringInstitute"NikolaTesla"
ControlDepartment
KosteGlavinica8a,Belgrade11000,Serbia

RISsistembesprekidnognapajanjajenamenjennapajanjumonofaznihnaizmeninihpotroaakoji
zahtevaju visok stepen sigurnosti napajanja zahvaljujui vanoj ulozi u okviru industrijskog procesa.
InstalacijomRISsistema,potroaisuzatieniodproblemakaotosufluktuacijanaponaifrekvencije,
propadi i nestanci napona, prenaponi atmosferskog i drugog porekla. Zatita je izvedena primenom
dvostepenekonverzije(doubleconversiononlineUPS)imejegarantovanvisokkvalitetizlaznognapona
potroaima se prua sinusni napon stabilne amplitude i frekvencije uz veliku otpornost na dinamiku
promenupotronje.
RISsistemjesastavljenodtricelinekojesusmeteneujedanormanispravlja,invertoristatika
preklopka(sarunimbajpasprebacivanjem),kaotojeprikazanonaslici1.Prioritetnonapajanjepotroaa
sevrisainvertoraprekobaterije,dokjespoljanjiizvoristovremenoirezervanapajanjausluajuotkaza
invertoraiizvorsnagezainvertor.Usluajunestankaspoljanjegnaizmeninogulazabaterijaobezbeuje
autonomiju rada u trajanju zavisno od kapaciteta spoljanje baterije. U sluaja otkaza ili iskljuenja
invertora, statika preklopka vri prebacivanje napajanja potroaa na pomoni ulaz bez pauze. U toku
servisa,runibajpasomoguavanapajanjepotroaadirektnoizpomonogizvora.

Slika 1: Blok-ema sistema RIS

Ispravlja
Ispravlja je namenjen za napajanje invertora i punjenje / odravanje u napunjenom stanju
akumulatorskebaterije.Izvedenjezasamostalanrad,bezueaoperatera.Predvienjedanapajainvertor
kod koga je bitna pouzdanost rada, dok promena napona i talasnost mogu da se kreu u odreenim
dozvoljenimgranicama.
Unormalnomradu,dokpostojinapajanjeizmree,ispravljaistovremenonapajainvertoripuni,
odnosno dopunjava spoljanju akumulatorsku bateriju. Pri nestanku mrenog napona, ulogu izvora
jednosmernognaponapreuzimaakumulatorskabaterija.Pritomenedolazidoprekidaunapajanjuinvertora,

Elektrotehnikiinstitut"NikolaTesla"
Centarzaauotmatikuiregulaciju
KosteGlavinia8a,11000Beograd,
tel.+381113952042email:info
@ieent.org

web:www.ieent.org

ElectricalEngineeringInstitute"NikolaTesla"
ControlDepartment
KosteGlavinica8a,Belgrade11000,Serbia

jerjesistembeznaponskepauze.Ponovnimuspostavljanjemmrenognaponaispravljasevraaureimu
komejebioprenestankamrenognapona.
Ispravlja puni bateriju po IU karakteristici. Ukoliko je baterija ispranjena ili delimino prazna,
ispravljaogranienomstrujompunjenjapunibaterijudoknaponnabaterijinedostignenaponodravanja.Tada
ispravlja preuzimaodravanjetognaponadokstruja poinje da opada. Za svevremepunjenja,stabilno
napajanjeinvertorajeobezbeeno.
Ispravljajekonstruisantakodaneprekidnovrinadzornadizlaznimveliinamaiusluajuproblemau
radupreduzimaodgovarajuuakciju,tj.zaustavljaureajiliulaziurestart,ukolikojeporemeajbioprolaznog
karaktera.
Komandovanjeispravljaemsevrilokalnodokseindikacijastanjaobezbeujelokalnoidaljinski.
Pomouinformacionogdisplejaostvarenjeuvidustanjeureaja,mereneveliine,delovanjezatitaiarhivu
dogaaja.
Invertor
Invertor koristi ulazni jednosmerni napon i pomou savremene poluprovodnike tehnologije ga
pretvaraumonofazninazimenininaponstabilneamplitudeifrekvencije220V/50Hz.Dobartalasnioblik
saizoblienjemmanjimod1%,statikastabilnostamplitudeboljaod2%zasveradnereimeidinamika
tanostunutar5%obezbeujedapotroainebuduometanipromenamaoptereenja.Tanostfrekvencijeje
odreena kristalnim oscilatorom i u slobodnom radu (bez sinhronizacije) je bolja od 50Hz 0,2%.
Sinhronizacijanapomoniulazjeosiguranauopsegu1Hzsadovoljnosporompromenomtakodanedoe
dotranzijentakojibimogaoometatipotroaeosetljivenanaglepromenefrekvencije.
Invertor je opremljen velikim brojem zatitinih funkcija od nadzora jednosmernih veliina i
iskljuenjuprinjihovomizlaskuizvanzadatihgranica,prekokontrolenazimeninihveliinanaizlazupasve
dogreakausinhronizaciji,temperaturnimradnimuslovimaidrugimradnimparametrima.Prikazradnog
stanjaipodeavanjeparametarasemoevritiprekoservisnogkomunikacionogporta.
Komandovanjeinvertoromsevrilokalnodokseindikacijastanjaobezbeujelokalnoidaljinski.
Statikapreklopka
Statikapreklopkajeprojektovanadapodriradsistemau online reimupotroaisetrajno
napajajusainvertoradokjemreniulazrezerva.Namreniulazseprelazisamousluajuzaustavljanja
invertora,preoptereenjakojeinvertornemoedapodriiliiskljuenjainvertorazbogdejstvazatite.Pri
ponovnomuspostavljanjunaponainvertora,napajanjepotroaasevraanainvertskiulaz.
Svaprebacivanjasevrebeznaponskepauze.Statikapreklopkarazlikujebezbednoprebacivanjeod
hitnog.Pribezbednomprebacivanjuvodiraunaosinhronizaciji,takodaizvornakojiseprelaziimaistu
frekvencijuifazukaoizvorkojipreuzimanapajanje.Hitnoprebacivanje(usluajuotkazailiiskljuenja)se
vritrenutno,beznaponskepauzekaobisespreiogubitaknapajanjapotroaa.
Statika preklopka stalno nadzire radne parametre invertora i mrenog ulaza. Ukoliko radni
parametri izau izvan zadatih granica, vri se automatsko prebacivanje na drugi raspoloivi izvor.
Sinhronizacijainvertoranamreujeosiguranasamoakosuradniparametrimreeunutarzadatihgranica.
Prekidaiustatikojpreklopcisuizvedeniuoblikuantiparalelnihtiristora imesepostiedobra
upravljivostuzvelikubrzinureagovanja.

Elektrotehnikiinstitut"NikolaTesla"
Centarzaauotmatikuiregulaciju
KosteGlavinia8a,11000Beograd,
tel.+381113952042email:info
@ieent.org

web:www.ieent.org

ElectricalEngineeringInstitute"NikolaTesla"
ControlDepartment
KosteGlavinica8a,Belgrade11000,Serbia

Statikapreklopkaraspolaeirunombajpaspreklopkomkojaomoguavadase,usluajuservisa,
izvrirunoprebacivanjenapajanjapotroaanamreniulaz.Tadajeomoguenoservisiranjeureajabez
uticajanaradpotroaa.
Radnistatusstatikepreklopkesedojavljujelokalnoidaljinski.
Rukovanje,komandaivizuelizacija
Sveakcijebitnezaradureajasevrerunolokalno,pomoutastera.
Indikacijastanjaprocesajeizvedenanavienaina:
pomou sinoptike table sa LED indikatorima, za pokazivanje stanja ispravnosti ulaza, izlaza i
delovasistema,
pomou tapanela na kojem je mogue stei uvid u radne reime, merenja, arhivu dogaaja i
alarma.
Daljinskasignalizacijajeizvedenapomoubeznaponskihrelejnihkontakata,zasvakideosistemaposebno.
Kontaktisupogodnizapovezivanjeukrugjednosmernogsignalnognapona220Vdc.
Runabajpaspreklopkaomoguavadase,usluajuservisa,izvrirunoprebacivanjenapajanjapotroaa
namreniulaz.Prebacivanjenapajanjapotroaasevribeznaponskepauze.Timejeomoguenobezbedno
servisiranjeureaja.

Elektrotehnikiinstitut"NikolaTesla"
Centarzaauotmatikuiregulaciju
KosteGlavinia8a,11000Beograd,
tel.+381113952042email:info
@ieent.org

web:www.ieent.org

ElectricalEngineeringInstitute"NikolaTesla"
ControlDepartment
KosteGlavinica8a,Belgrade11000,Serbia

Tehnikekarakteristike

Ispravlja:
Naponnapajanja.............................................................................................................3x380V15%
Uestanostnaponanapajanja................................................................................................50Hz1%
Tipgalvanskeizolacije.......................................................................................................transformator
Nominalnastrujaispravljaa..........................................................................................................110A
Nominalninaponbaterije...........................................................................................................240Vdc
Naponpunjenjabaterije......................................................................................(2,27VPC)272V1%
Naponispranjenebaterije..................................................................................(1,85VPC)222V1%
Maksimalnastrujapunjenjabaterije.........................................................................(0,2C10)20A1%
Maksimalnastrujainvertora...................................................................................................90A1%
Izlazninaponispravljaa
prinormalnomradu(punjenje)...............................................................................272V1%
pripranjenjubaterije.......................................................................................222Vdo272V
Zatite: prenaponska,podnaponska,prekostrujnaispravljaa,prekostrujnabaterije,nestanakACfaze,
nestanakACnapona,grekaregulatora,prekidbaterije,nesimetrijatiristorskogmosta,ripl
izlaznognapona.
Radnadizelagregatu........................................................................................................................DA
Merenjalokalna................................................................................................................naponbaterije
Merenjadaljinska...............................................................................................naponbaterije,420mA
Signalizacija:...............................................................................................................lokalnoidaljinski

Invertor
Izlazninapon...............................................................................................................230Vrms2%
Izlaznafrekvencija..............................................................................50Hz0,2%uradubezmree,
50Hz1Hzureimusinhronizacije
Izlaznasnaga................................20kVA(zanominalnicos=0,8induktivnoilinearnooptereenje)
Faktorsnagepotroaa...........................................................................................0,81,0induktivno
Izoblienjeizlaznognapona........................................................1%maksimalnozanominalneuslove
Preoptereenje.........................................................................................................125%za10minuta
150%za60sekundi
ienjekratkogspoja........................................................................................3xInomza10sekundi
Promenanaponapritranzijentima.........................................................................................5%max

Elektrotehnikiinstitut"NikolaTesla"
Centarzaauotmatikuiregulaciju
KosteGlavinia8a,11000Beograd,
tel.+381113952042email:info
@ieent.org

web:www.ieent.org

ElectricalEngineeringInstitute"NikolaTesla"
ControlDepartment
KosteGlavinica8a,Belgrade11000,Serbia

Vremesmirenja..............................................................................................................................5ms
Sinhronizacijanamreniulaz............................................................................................................da
Brzinapromenefrekvencije........................................................................................................0,2Hz/s
Galvanskaizolacijaizlaza..................................................................................................transformator
Signalizacija:...............................................................................................................lokalnoidaljinski

Statikapreklopka
Ulazninaponmree...................................................................................................220Vrms15%
Ulaznafrekvencijamree..............................................................................................50Hz1,0Hz
Galvanskaizolacija............................................................................transformatornamrenomulazu
Vremeprebacivanja.....................................................................................................................2ms
Radnadizelagregatu............................................................................DA,bezsinhronizacijeinvertora
Merenjalokalna..................................................................................................naponistrujapotroaa
Merenjadaljinska.................................................................................naponistrujapotroaa,420mA
Signalizacija:...............................................................................................................lokalnoidaljinski

Optetehnikekarakteristike
Komandovanje....................................................................................runotasterima,savrataormana
Lokalnasignalizacija.......................................................................LEDindikatorinavratimaormana
tapanelzaprikazreima
Daljinskasignalizacija...................................beznaponskirelejnikontakti230Vac5A/220Vdc0.5A
Lokalnamerenja.......................................naponbaterije,naponistrujapotroaa,panelmetarDIN96
Daljinskamerenja.....................................................naponbaterije,naponistrujapotroaa,420mA
Stepeniskorienja..............................................>90%prinominalnomoptereenjupripunojbateriji
um(buka).............................................................................................................................max65dB
Radnatemperatura....................................................................................................................040C
Nainhlaenja...........................................................................................................................prirodno
Relativnavlanost.......................................................................................................................do90%
Stepenzatite..................................................................................................................................IP20
Nainmontae................................................................................................................slobodnostojei
Prilazkablova..............................................................................................................................odozdo
DimenzijeSBNa.......................................................................................800mmx800mmx2200mm

Elektrotehnikiinstitut"NikolaTesla"
Centarzaauotmatikuiregulaciju
KosteGlavinia8a,11000Beograd,
tel.+381113952042email:info
@ieent.org

web:www.ieent.org

ElectricalEngineeringInstitute"NikolaTesla"
ControlDepartment
KosteGlavinica8a,Belgrade11000,Serbia