INSTALLATION MANUAL

Mini-Split Air Conditioner


YLHJZH009~BARXAFX

001056

1
2
3
4
6
5

7
8

Display board

1 Remote signal receiver


(A beeping sound is generated when a signal from remote controller isreceived.)

2 Power indicator

(Lights up when unit starts.)

3 Timer mode indicator

(Lights up whenTimer operation is selected.)

4 Operation mode indicator

(lights up when the compressor is on.)

5 Ambient temp display

When receiving the remote control signal, display the set temperature.

POWER/SOFT button is not available for 07k09k12k.

Operation
Emergency operation and test operation

Base Operation

Emergency Operation:
Remote controller

Room
Operation Designated Timer
temperature mode
temperature mode
COOLING

26 C

NO

AUTOMATIC

BELOW 23OC

HEAT

23OC

NO

AUTOMATIC

cooling only
Room temperature
O

BELOW 23 C

Press ON/OFF on the remote controller, unit starts.

2.Select operation mode

Press MODE button. For each press, operation mode


changes as follows:
Remote controller:
AUTO

COOL

DRY

FAN

HEAT

3.Select temp.setting

Press TEMP+ / TEMP- button


time the button is pressed, temp.setting
increase 1oC,if kept depressed, it will increase
rapidly
TEMP- Every time the button is pressed, temp.setting
decrease 1oC,if kept depressed, it will decrease
rapidly
Select a desired temperature.

TEMP+ Every

4.Fan speed selection

Press FAN SPEED button. For each press, fan speed


changes as follows:
Remote controller:
LOW

MED

AUTO

HI

Air conditioner is running under displayed fan speed.


When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
Operation Remote Display
Controller Board
Mode

DRY

Note
Under the mode of auto operation, air conditioner will
automatically select Cool or Heat operation according
to room temperature. When FAN is set to AUTO, the
air conditioner automatically adjusts the fan speed
according to room temperature.

In DRY mode, when room temperature becomes


lower than temp.setting+2 oC,unit will run intermittently
at LOW speed regardless of FAN setting.

HEAT

FAN

Operation Designated Timer


Air flow
mode temperature mode
O
FAN
AUTOMATIC
NO
26 C

It is not possible to operate in dry mode.

1. Unit start

COOL

Air flow

ABOVE 23 C
O

AUTO

Pi

Use this operation only when the remote controller


is defective or lost.
When the emergency operation switch is
pressed,the" Pi "sound is heard once, which
means the start of this operation.
In this operation, the system automatically selects
the operation modes,cooling or fan or heat,
according to the room. temperature.

In FAN operation mode, the unit will not operate in


COOL or HEAT mode but only in FAN mode ,AUTO is
not available in FAN mode.And temp.setting is disabled.
In FAN mode,SLEEP operation is not available.

Test operation:
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room
o

temperature is below 16 C, do not use it in the


normal operation.

Pi Pi

Continue to press the test operation


switch for more than 5 seconds . After
you hear the "Pi" sound twice, release
your finger from the switch: the cooling

operation starts with the air flow speed "Hi".

Air Flow Direction Adjustment


1.Status display of air flow
Vertical flap
Pos.1

Pos.2

Pos.3

Pos.4

Pos.5

(Auto swing)

2.Left and right air flow adjustment(manual)

Move the vertical blade by a knob on air conditioner


to adjust left and right direction referring to Fig.
Remote controller can memorize each operation status. When starting it
next time,just press ON/OFF button and unit will run in previous status.

Cautions:

When adjusting the flap by hand,turn off the unit.


When humidity is high,condensate water might occur
at air outlet if all vertical louvers are adjusted to left or
right.

It is advisable not to keep horizontal flap at downward


position for a long time in COOLor DRY mode ,
otherwise, condensate water might occur.
Note:
When restart after remote turning off, the remote
controller will automatically memorize the previous
set swing position.

Operation
Sleep Operation

5.Set the wind speed change when sleeping If the

Before going to bed,you can simply press the SLEEP


button and unit will operate in SLEEP mode and bring
you a sound sleep.

wind speed is high or middle before setting for the


sleep, set for lowing the wind speed after sleeping.
If it is low wind, no change.

Note

When TIMER function is set, the sleeping function can't


be set up .After the sleeping function is set up,if user
resets TIMER function, the sleeping function will be
cancelled;the machine will be in the state of timing-on.

POWER/SOFT Operation

(1) POWER Operation

Use of SLEEP function

After the unit starts,set the operation status,then press


SLEEP button before which the clock must be adjusted
and time being set.

Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts,temp.will become
1OC higher than temp.setting.After another 1 hours,
temp.rises by 1OC futher.The unit will run for further
6 hours then stops Temp. is higher than temp.setting
so that room temperature wont be too low for your sleep.
SLEEP operation starts

SLEEP operation stops


Approx.6hrs
Rises 1OC

1 hr

Unit stop

In COOL, DRY mode

2. In HEAT mode

1 hours after SLEEP mode starts,temp will become


2 lower than temp.setting.After another 1 hours,
temp decrease by 2 futher. After more another 3
hours,temp.rises by 1 futher.The unit will run for
further 3 hours then stops.Temp.is lower than temp.
setting so that room temperature wont be too high
for your sleep.
Temp.setting

Unit stop

Decreases 2OC
1 hr

Decreases 2OC
3 hrs
3 hrs

SLEEP
operation starts

Rises 1OC

SLEEP
operation stops

In HEAT mode

3. In AUTO mode

The unit operaters in corresponding sleep mode adapted


to the automatically selected operation mode.

4. In FAN mode

It has no SLEEP function.

takes low speed of AUTO fan mode.

Note

During POWER operation, in rapid HEAT or COOL mode,


the room will show inhomogeneous temperature
distribution. Long period SOFT operation will cause effect
of not too cool or not too warm.
To cancel POWER or SOFT operation
Press POWER/SOFT button again ,POWER or SOFT disappears.
Cooling only unit do not have displays and functions related with heating.

Temp.setting

1 hr

In COOL mode, fan speed automatically takes high speed of


AUTO fan mode. In HEAT mode, fan speed automatically
takes medial speed of AUTO fan mode.
(2) SOFT Operation
You can use this function when silence is needed for rest or
reading. In SOFT operation mode, fan speed automatically

NOTE:

Rises 1OC

1 hr

When you need rapid heating or cooling, you can use this function.

Healthy airflow Operation


1.Press ON/OFF to starting
Setting the comf ort work conditions .
2.The setting of healthy airflow function
appears on the
1).Press the button of healthy airflow ,
display. Horizontal airflow sending. Avoid the airflow
blows direct to the body.
2).Press the button of healthy airflow again,
appears on
the display. Downward airflow sending. Avoid the airflow
blows direct to the body.
3.The cancel of the healthy airflow function
Press the button of healthy airflow again, the unit goes on
working under the condition before the setting of healthy
airflow function.
Notice: Do not direct the flap by hand. Otherwise, the
grille will run incorrectly. If the grille is not run correctly, stop
for a minute and then start, adjusting by remote
controller.
Note:
1.After setting the healthy airflow function, the position
grill is fixed.
2.In heating, it is better to select the
mode.
3.In cooling, it is better to select the
mode.
4.In cooling and dry, using the air conditioner for a long
time under the high air humidity, condensate water may
occur at the grille .

Operation
Timer On/Off On-Off Operation
Set clock correctly before starting TIMER operation.
1.After unit starts, select your desired operation mode.
2.Press TIMER button to change TIMER mode. Every
time the button is pressed, display changes as follows:
Remote controller:
BLANK
TIMER ON

TIMER OFF

TIMER ON-OFF

Then select your desired TIMER mode (TIMER ON or


TIMER OFF or TIMER ON-OFF). "
"or "
"will flash.
3.Press TIME+ /TIME- button to set time.
It can be adjusted within 24 hours.
4.After setting correct time, press SET button to confirm
"
"or"
" on the remote controller stops flashing.
5.Cancel TIMER mode
Just press TIMER button several times until TIMER mode
disappears.
Hints:
After replacing batteries or a power failure happens, time
setting should be reset.
Remote controller possesses memory function,when use
TIMER mode next time, just press SET button after mode
selecting if time setting is the same as previous one.
According to the Time setting sequence of TIMER ON or
TIMER OFF, either Start-Stop or Stop-Start can be achieved.

EUROPEAN REGULATIONS
CONFORMITY FOR THE MODELS
CE

All the products are in conformity with the following


European provision:
- Low Voltage Directive 2006/95/EC
-Electomagnetic CompatibilitY 2004/108/EC

ROHS

The products are fulfilled with the requirements in the


directive 2011/65/EU of the European parliament and of
council on the Restriction of the use of Certain Hazardous
Substances in Electrical and Electronic Equipment (EU
RoHS Directive)

WEEE

In accordance with the directive 2012/19/EU of the European


parliament, herewith we inform the consumer about the disposal requirements of the electrical and electronic products.

DISPOSAL REQUIREMENTS:

Your air conditioning product is marked with this


symbol.This means that electrical and electronic
products shall not be mixed with unsorted
household waste. Do not try to dismantle the
system yourself : the dismantling of the air
conditioning system,treatment of the refrigerant, of oil and of
other part must be done by a qualified installer in accordance
with relevant local and national legislation. Air conditioners
must be treated at a specialized treatment facility for reuse,
recycling and recovery. By ensuring this product is disposed
of correctly, you will help to prevent potential negative consequences for the environment and humen health. Please
contact the installer or local authority for more information.
Battery must be removed from the remote controller and disposed of separately in accordance with relevant local and
nationl legislation.

IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED


Contains fluorinated greenhouse gases
covered by the Kyoto Protocol

R410A

1=

kg

2=

kg

1+2=

kg

1
F

A
B
C
D

This product contains fluorinated greenhouse gases covered by


the Kyoto Protocol. Do not vent into the atmosphere.
Refrigerant type:R410A
GWP* value:1975
GWP=global warming potential
Please fill in with indelible ink,
1
the factory refrigerant charge of the product
2
the additional refrigerant amount charged in the field and
1+2 the total refrigerant charge
on the refrigerant charge label supplied with the product.
The filled out label must be adhered in the proximity of the product
charging port (e.g. onto the inside of the stop value cover).
A contains fluorinated greenhouse gases covered by the Kyoto
Protocol
B factory refrigerant charge of the product: see unit name plate
C additional refrigerant amount charged in the field
D total refrigerant charge
E outdoor unit
F refrigerant cylinder and manifold for charging

Indoor Unit Installaion


Necessary Tools for Installation
Driver
Nipper
Hacksaw
Hole core drill
Spanner(17,19 and 26mm)
Gas leakage detector or
soap-and-water solution

Torque wrench
(17mm,22mm,26mm)
Pipe cutter
Flaring tool
Knife
Measuring tape
Reamer

Power Source
Before inserting power into receptacle, check the voltage without
fail.
The power supply is the same as the corresponding nameplate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable
can be reached.Do not extend the cable by cutting it.

Selection of Installation Place

Accessory Parts

Place, robust not causing vibration, where the body can be


supported sufficiently.
Place, not affected by heat or steam generated in the vicinity,
where inlet and outlet of the unit are not disturbed.
Place, possible to drain easily, where piping can be connected with the outdoor unit.
Place,
where cold air can be spread in a room entirely.

Place, nearby a power receptacle, with enough space around.


Place where the distance of more than lm from televisions,
radios, wireless apparatuses and fluorescent lamps can be
left.
In the case of fixing the remote controller on a wall, place
where the indoor unit can receive signals when the fluorescent lamps in the room are lightened.

Remote controller (1)

Drain hose (1)

R-03 dry battery (2)

Plastic cap (4)


4X25 Screw (4)

Mounting plate (1)

Air purifying filter(Optional) (1)

Selection of Pipe
FOR 09K 12K
FOR 18K
FOR 24K

Drawing for the installation of indoor units


The models adopt HFC free refrigerant R410A

more than 15 cm

Attention must be paid to


the rising up of drain hose

Arrangement of piping
directions
Rear left

more than
10cm

Rear
right

Left

Right
Below

more than 10cm


The distance between the indoor unit and the floor should be more than 2m.
Please be subject to the actual product purchased,the above picture is just for your reference.

Indoor Unit Installation


Fitting of the Mounting Plate and Positioning of the wall Hole
When the mounting plate is first fixed
1. Carry out, based on the neighboring pillars or lintels, a proper leveling
for the plate to be fixed against the wall, then temporarily fasten the plate
with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread
with a weight from the central top of the plate, then fasten securely the
plate with the attachment steel nail.
3. Find the wall hole location A using a measuring tape

[ Left Left-rear piping ]

In case of left side piping, cut away, with a nipper, the lid for left
piping.
In case of left-rear piping, bend the pipes according to the piping
direction to the mark of hole for left-rear piping which is marked on
heat insulation materials.
1. Insert the drain hose into the dent of heat insulation materials of
indoor unit.
2. Insert the indoor/outdoor electric cable from backside of indoor
unit, and pull it out on the front side, then connect them.
3. Coat the flaring seal face with refrigerant oil and connect pipes.
Cover the connection part with heat insulation materials closely,
and make sure fixing with adhesive tape
Indoor/outdoor electric cable
Heat insulation
material
Lid for right
piping
Lid for under piping pipe

Piping
Pipe supporting
plate

Lid for left piping Drain hose

Fix with adhesive tape


B= 60mm

A=125mm

A=95mm

30mm

30mm

B= 60mm

Pay attention to the following points before installation of machine:


1. Take out cushion blocks on the left
and right angle beads as shown in
the following Figure.
2. Remove 2 gaskets under the
cross-flow fan.

Indoor/outdoor electric cable and drain hose must be bound with


efrigerant piping by protecting tape.

[ Other direction piping ]


Cut away, with a nipper, the lid for piping according to the piping
direction and then bend the pipe according to theposition of wall
hole. When bending, be careful not to crash pipes.
Connect beforehand the indoor/outdoor electric cable, and then
pull out the connected to the heat insulation of connecting part
specially.

Fixing the indoor unit body

3. Clean the burr on the surface of fracture


to avoid the power wire from being scratched after removing the
virtual opening of the outgoing
line slot on the case by
hands in indoor
power-on process.

When the mounting plate is fixed side bar and lintel


Fix to side bar and lintel a mounting bar, Which is separately sold, and
then fasten the plate to the fixed mounting bar.
Refer to the previous article, When the mounting plate is fi rst fixed ,
for the position of wall hole.

Hang surely the unit body onto the upper


notches of the mounting plate. Move the body
from side to side to verify its secure fixing.
In order to fix the body onto the mounting
plate,hold up the body aslant from the
underside and then put it down perpendicularly.

mounting plate

Unloading of indoor unit body


When you unload the indoor unit,please use your hand to arise
the body to leave agraffe,then lift the bottom of the body outward
slightly and lift the unit aslant until it leaves the mounting plate.

Making a Hole on the Wall and Fitting the Piping Hole Cover
Make a hole of 70 mm in diameter, slightly descending to outside the wall
Install piping hole cover and seal it off with putty after installation
Wall hole

agraffe

70mm

mounting plate

Connecting the indoor/outdoor Electric Cable


Indoor side

(Section of wall hole)

Thickness of wall

Outdoor side

G Piping hole pipe

Installation of the Indoor Unit


Drawing of pipe

[ Rear piping ]
Draw pipes and the drain hose, then fasten them with the adhesive tape

Removing the wiring cover


Remove terminal cover at right bottom corner of
indoor unit, then take off wiring cover by removing
its screws.

Correct

When connecting the cable after installing the indoor unit


1. Insert from outside the room cable into left side of the wall
hole, in which the pipe has already existed.
2. Pull out the cable on the front side, and connect the cable
making a loop.

When connecting the cable before installing the indoor unit

Lean

Damage of flare

Crack

Partial

Too outside

On Drainage

Please install the drain hose so as to be downward slope without fail.


Please dont do the drainage as shown below.

side of the unit, then pull it out on the front side.

Insert the cable from the back


Loosen the screws and insert

Incorrect

the cable ends fully into terminal block, then


tighten the screws.
Pull the cable slightly to make sure the cables have been properly inserted and
tightened.
After the cable connection, never fail to fasten the connected cable with the
wiring cover.

Indoor unit

Less than
5cm
It becomes The end is imm- It waves. The gap with the
There is the bad
high midway. ersed in water.
ground is too small. smell from a ditch

Please pour water in the drain pan of the indoor unit, and confirm that
drainage is carried out surely to outdoor.

In case that the attached drain hose is in a room, please


insulation to it without fail.

To Outdoor unit

Note:

When connecting the cable, confirm the terminal number of indoor and
outdoor units carefully. If wiring is not correct, proper operation can not
be carried out and will cause defect.

Connecting wiring

4G0.75mm

Power Source Installation

The power source must be exclusively used for air conditioner.


In the case of installing an air conditioner in a moist place, please install
an earth leakage breaker.
For installation in other places, use a circuit breaker as far as possible.

Cutting and Flaring Work of Piping

Pipe cutting is carried out with a pipe cutter and burs must be removed.
After inserting the flare nut, flaring work is carried out.

Flare tool for R410A

Conventional flare tool

Clutch-type

clutch-type(Rigid-type) Wing-nut type (Imperial-type)

0~0.5mm

Flare tooling die

1.0~1.5mm

1.Cut pipe

3.Insert the flare nut

On Drainage

C od e
T rouble description
indication

1.5~2.0mm

2.Remove burs

4.Flare pipe

A nalyze and diagnose

E1

Room temperature
sensor failure

E2

H eat-exc hange
sensor failure

E4

Indoor E E P R O M
error

F au lty E E P R O M da ta;
F au lty E E P R O M ;
F au lty P C B ;

E7

C om m unication
fault betw een
indoor and outdoor
units

Indoor unit- outdoor unit signal


transm ission error du e to w iring
error;
F aulty P C B ;

Indoor fan m otor


m alfunc tion

O peration halt due to breaking


of w ire ins ide the fan m otor;
O peration halt due to breaking
of the fan m otor lead w ires;
D etection error due to faulty
indoor unit P C B ;

1. If the supply cord is damaged, it must be replaced by the manufacturer or its


service agent or a similar qualified person. The type of connecting wire is
H05RN-F or H07RN-F.
2. If the fuse on PC board is broken please change it with the type of
T.3.15A/250VAC (Indoor).
3. The wiring method should be in line with the local wiring standard.
4. After installation, the power plug should be easily reached.
5. A breaker should be incorporated into fixed wiring. The breaker should be
all-pole switch and the distance between its two contacts should be not less
than 3mm.

apply heat

E 14

F aulty connector connection;


F aulty therm istor;
F aulty P C B ;

 Check for Installation and Test Run


Please kindly explain to our customers how to
operate through the instruction manual.

Check Items for Test Run


Put check mark

in boxes

Gas leak from pipe connecting?


Heat insulation of pipe connecting?
Are the connecting wirings of indoor and outdoor firmly
inserted to the terminal block?
Is the connecting wiring of indoor and outdoor firmly fixed?
Is drainage securely carried out?
Is the earth line securely connected?
Is the indoor unit securely fixed?
Is power source voltage abided by the code?
Is there any noise?
Is the lamp normally lighting?
Are cooling and heating (when in heat pump) performed normally?
Is the operation of room temperature regulator normal?

Maintenance
For Smart Use of The Air Conditioner
Setting of proper room
temperature

Do not block the air inlet


or outlet

Remote Controller

Indoor Body

wipe the air conditioner by using a


soft and dry cloth.For serious stains,
use a neutral detergent diluted with
water.Wring the water out of the
cloth before wiping,then wipe off the
detergent completely.

Proper
temperature

Do not usewater,wipe the controller


with a dry cloth.Do not use glass
cleaner or chemical cloth.

Do not use the following for cleaning

Use the timer effectively

Close doors and windows


during operation

Gasoline,benzine, thinner or cleanser


may damage the coating of the unit.

Hot water over 40 O C(104O F) may


cause discoloring or deformation.

Air Filter cleaning

During cooling operation


prevent the penetration
of direct sunlight with
curtain or blind

Open the inlet grille by pulling it upward.


Remove the filter.

Push up the filter's center tab slightly until it is


released from the stopper, and remove the filter downward.

Use the louvers effectively

If the unit is not to be used


for a long time, turn off the
power supply main switch.

Clean the filter.

Use a vacuum cleaner to remove dust, or wash the filter with


water.After washing, dry the filter completely in the shade.

Attach the filter.

Attach the filter correctly so that the "FRONT" indication


is facing to the front.Make sure that the filter is
completely fixed behind the stopper.If the right
and left filters are not attached correctly, that
may cause defects.

OFF

Once every
two weeks

Close the inlet grille.

Replacement of Air Purifying Filter


(NOTE: Air purifying filter is optional part)
1.Open the lnlet Grille
Prop up the inlet grille by using a
small device named grille-support
which located in the right side of
the indoor unit.

2.Detach the standard air filter


Slide the knob slightly upward to
release the filter, then withdraw it.

4.Attach the standard air filter


(Necessary installation)

ATTENTION:
The white side of the photocatalyst air purifying filter
face outside,and the black side face the unit The green
side of the bacteria-killing medium air purifying filter face
outside,and the white side face the unit.

5.Close the Inlet Grille


Close the Grille surely

Detach old Air Purifying Filter

3.Attach Air Purifying Filter


Put air purifying filter appliances into the
right and left filter frames.

NOTE:

The photocatalyst air purifying filter will be solarized in fixed


time. In normal family, it will be solarized every 6 months.

The bacteria-killing medium air purifying filter will be used


for a long time,no need for replacement. But in the period
of using them ,you should remove the dust frequently by
using vacuum cleaner or flaping them lightly,otherwise ,
its performance will be affected.
Please keep the bacteria-killing medium air purifying filter in
the cool and dry conditions avoid long time directly sunshine
when you stop using it,or its ability of sterilization will be
reduced.

Cautions
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works
may cause electric shock, fire, water leakage.

When abnormality such as burnt-small found,


immediately stop the operation button and
contact sales shop.

WARNING

Use an exclusive
power source
with a circuit
breaker

STRICT
ENFORCEMENT

OFF
Connect power supply cord
to the outlet completely

STRICT
ENFORCEMENT

Use the proper voltage

STRICT
STRICT
ENFORCEMENT
ENFORCEMENT
Take care not to damage
Do not use power supply
the power supply cord.
cord in a bundle.

Do not start or stop the


operation by disconnecting
the power supply cord
and so on.

1.Do not use power supply cord extended


or connected in halfway
2.Do not install in the place where there is any
possibility of inflammable gas leakage around the unit.
3.Do not get the unit exposed
to vapor or oil steam.
PROHIBITION
Do not insert objects into the air
inlet or outlet.

PROHIBITION

PROHIBITION

PROHIBITION

Do not channel the air flow directly


at people, especially at infants or
the aged.

PROHIBITION

Do not use for the purpose of storage of


food, art work, precise equipment,
breeding, or cultivation.

PROHIBITION
Do not install the unit near a fireplace
or other heating apparatus.

PROHIBITION
Do not place animals or plants in
the direct path of the air flow

PROHIBITION
9

Check proper
installation of the
drainage securely

Do not try to repair or


reconstruct by yourself.

Connect the earth


cable.

earthing

PROHIBITION

CAUTION

Take fresh air occasionally especially


when gas appliance is running at the
same time.
STRICT
ENFORCEMENT
Check good condition of the
installation stand

Do not operate the switch with


wet hand.

PROHIBITION
Do not pour water onto the unit
for cleaning

PROHIBITION

PROHIBITION
Do not place any objects on or
climb on the unit.

PROHIBITION

Do not place flower vase or water


containers on the top of the unit.

PROHIBITION

Trouble shooting
Before asking for service, check the following
first.
Phenomenon
The system
does not restart
immediately.

Noise is heard

Normal
Performance
inspection

Smells are
generated.
Mist or steam are
blown out.

In dry mode, fan


speed cant be
changed.

Cause or check points


When unit is stopped, it won't restart
immediately until 3 minutes have
elapsed to protect the system.
When the electric plug is pulled out
and reinserted, the protection circuit
will work for 3 minutes to protect the
air conditioner.
During unit operation or at stop,
a swishing or gurgling noise may
be heard.At first 2-3 minutes after
unit start, this noise is more noticeable.
(This noise is generated by
refrigerant flowing in the system.)
During unit operation, a cracking
noise may be heard.This noise is
generated by the casing expanding
or shrinking because of
temperature changes.
Should there be a big noise from
air flow in unit operation, air
filter may be too dirty.
This is because the system
circulates smells from the interior
air such as the smell of furniture,
paint, cigarettes.
During COOL or DRY operation,
indoor unit may blow out mist.
This is due to the sudden cooling
of indoor air.
In DRY mode, when room temperature
becomes lower than temp.
setting+2 oC,unit will run
intermittently at LOW speed
regardless of FAN setting.
Is power plug inserted?
Is there a power failure?
Is fuse blownout?

Multiple
check

Poor cooling

Is the air filter dirty?


Normally it should be cleaned
every 15 days.
Are there any obstacles before
inlet and outlet?
Is temperature set correctly?
Are there some doors or
windows left open?
Is there any direct sunlight
through the window during the
cooling operation?(Use curtain)
Are there too much heat sources
or too many people in the room
during cooling operation?

Cautions
Do not obstruct or cover the ventilation grille of the air
conditoner.Do not put fingers or any other things into the
inlet/outlet and swing louver.
This appliance is not intended for use by persons (including children)
with reduced physiced, sensory or mental capabilities or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of appliance by person responsible for
their safety. Children should be supervised to ensure that they do not
play with the appliance.

Specifications
The refrigerating circuit is leak-proof.

The machine is adaptive in following situation


1.Applicable ambient temperature range:

Indoor
Cooling

Maximum:D.B/W.B 46oC/26oC
18oC
Maximum:D.B
27oC
Minimum: D.B
15oC

Outdoor Minimum: D.B


Indoor

Heating

Maximum:D.B/W.B 32oC/23oC
Minimum:D.B/W.B 21oC/15oC

Outdoor

Maximum:D.B/W.B 24oC/18oC
Minimum:D.B/W.B - 7 oC/-8oC

o
o
Outdoor Maximum:D.B/W.B 24 C/18 C
(INVERTER)

Minimum:D.B

-15oC

2. If the power supply cord is damaged, it must be replaced by the


manufacturer or its service agent or a similar qualified person.
3.If the fuse of indoor unit on PC board is broken,please change
it with the type of T. 3.15A/ 250V. If the fuse of outdoor unit is
broken,change it with the type of T.25A/250V
4. The wiring method should be in line with the local wiring standard.
5. After installation, the power plug should be easily reached.
6. The waste battery should be disposed properly.
7. The appliance is not intended for use by young children or infirm
persons without supervision.
8. Young children should be supervised to ensure that they do not play
with the appliance.
9. Please employ the proper power plug, which fit into the power supply
cord.
10. The power plug and connecting cable must have acquired the local
attestation.
11.In order to protect the units,please turn off the A/C first, and at least
30 seconds later, cutting off the power.

2014 Johnson Controls, Inc.

www.johnsoncontrols.co m

U1HJZHARZ-140113

Johnso n Controls reserve the right to change product features without prior notice .