OW - 300 (Agar) PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

AGAR CORPORATION

Process Measurement & Control

OW-300 Series Oil/Water Meters


Liquid/Liquid Concentration
DESCRIPTION
The AGAR OW-300 Series oil/water meters measure liquidin-liquid concentrations by measuring the complex permittivity
properties of the flow stream using a multiple high frequency
method. Typical applications include crude oil and finished
product pipeline monitoring, water in slop oil, glycol and water,
and aqueous/organic measurement. The OW-300 Series is
the third-generation design, liquid/liquid analyzer developed
by Agar Corporation. Agar introduced the industrys first
0-100% oil/water meter to the market in 1985.
System Configuration
The OW-300 system consists of a primary probe, the
measurement electronics, and a data analysis system
(DAS) that can be remotely mounted from the field sensor.
The OW-300 probe is offered in a spool-type configuration
and insertion-type assembly.
The instruments are calibrated using Windows-based
software from a laptop computer. The software is also
used for troubleshooting, viewing trends, and retrieving
historical data.

OW-302 Series Installation Venezuela

The OW-300 Series utilizes a combination of explosion-proof enclosures and intrinsically-safe


electronics that provide signal outputs/inputs to the probe. The DAS is also a flow computer that
can provide net oil, net water and flow rates when flow meter input is supplied. The data system is
transmitted with 4-20mA signals, HART and MODBUS.

TYPICAL APPLICATIONS:

Pipeline BS&W measurement for refined


products

Crude pipelines
Desalter crude feed

Well testing
LACT units
Separation control
Shipping terminals

www.agarcorp.com
All Agar Corporation Instruments are covered by one or more of the following U.S. Patents: 4,503,383; 4,774,680; 5,099,697; 5,101,163; 5,101,367;
5,263,363; 5,503,004; 5,551,305; 5,589,642; 5,741,977, RE 36,597. Other patents pending in the USA and other countries.

OW-301 Spool Piece Design


DESCRIPTION
The AGAR OW-301 is a Spool Piece design available for 1 to 4
flow lines. The sensor should be mounted in a location where the
Sizes: 1 to 4
fluid will be well mixed (normal recommendation is vertical flow
upwards). The spool piece is available in an L or S shaped
design. In addition, the OW-301 will have a stable performance in common pipelines when the fluid composition changes
regularly.
The AGAR OW-300 measures hydrocarbon/water mixtures over the range of 0-40%, water (oil continuous emulsions). The
Agar OW-301 accuracy of measurement will not be affected by changing salinity, density, viscosity, and temperature of the
components being analyzed.

SYSTEM CONFIGUATION
The OW-301 system consists of an in-line probe, the measurement electronics, and a Data Analysis System (DAS)
that can be remotely mounted from the field sensor. The probe is offered in a spool type configuration.

PHYSICAL DIMENSIONS
Electrical Enclosure

Diameter: 6
Length: 12
Spool Design
for 1 to 4 pipeline sizes
Flange Rating
150#; 300#; 600#; 900#; 1500# Consult factory for others
Maximum Pressure Rating 5000PSI
Shipping Weight
Approximately 25lbs for 2 ANSI 150#

OW-301 Series

World-Class Process Measurement & Control Solutions

OW-302 Insertion Type


DESCRIPTION
Unlike other microwave, density or capacitance based
instruments; Agars OW series meters are the only devices
Sizes 6 and above
in which the accuracy of the measurement is not affected by
changing salinity, density, viscosity, temperature or velocity of
the components being analyzed. The high frequency signal
will maintain accuracy in the presence of process coatings that would be detrimental to optical instruments.
The Agar patented seal-housing connects to the isolation valve. After installation, the OW-302 probe is inserted
through the valve and nozzle into the flow line. Agars OW-302 monitor features an insertable sensor with a seal
housing for installation and retraction while the pipeline is in service and under pressure for flow lines 6 and
larger. An insertion tool is available for insertion into high pressure lines. The sensor has a blow-out preventer
to ensure that the sensor is not removed from the seal housing without the isolation valve being closed.
SYSTEM CONFIGURATION
The OW-302 system consists of a primary insertion-type probe, the measurement electronics, and a Data Analysis
System (DAS) that can be remotely mounted from the field sensor. The probe is offered in an insertion type
assembly. The OW-302 probe is mounted perpendicular to the flow in a vertical section with ascending flow at a
point where the fluids are well mixed to ensure proper measurement. Common installation requires a 2 full port
isolation valve connected directly to the nozzle on the flow line.

OW-302 Series

PHYSICAL DIMENSIONS
Electrical Enclosure
Diameter: 6
Length: 12
Probe Diameter
1.25 diameter shaft
1.8 diameter sensor
Probe Length
Active Length: 6 to 12 to match
the diameter of the pipe
Overall Length is determined by
the pipe diameter, nozzle, and
valve size with standard lengths
Insertion Design
for 6 and larger pipeline sizes
Process connection minimum 2
full port ball or gate valve
2 schedule 80 or larger ID nozzle
Flange Rating
150#; 300#; 600#; 900#; 1500#
Consult factory for others
Maximum Pressure
5000PSI
Rating
Shipping Weight
Approximately 25lbs for 2 ANSI
150#
Insertion Tool
Recommended for OW-302 when
operating pressure is over 60PSI
and flange rating is 600# or less

www.agarcorp.com

PROCESS CONDITIONS
Ambient Temperature

0F to 140F (-15C to 60C)


Optional Low Temp -40F to 140F (-40C to 60C) with insulation

Process Temperature

Standard Model 32F to 212F (0C to 100C)


High Temperature Model 32F to 450F (0C to 232C)

Wetted Parts*

Stainless Steel; Ceramic; PEEK; Viton

Options
Metallic parts: Duplex, Monel, Hastelloy, Elastomers - Teflon, PDMA
Vibration
5g at 500 Hz
* Consult factory for other available materials
POWER SUPPLY

Standard: 12 to 36 VDC 15% Isolated


Optional: 110 to 220 VAC
Others available upon request
Power Requirements: 25 Watts

MEASUREMENT CAPABILITIES & ACCURACY

Range*

Absolute
Accuracy

Repeatability
of Span

0 to 1%

0.05%

0.1%

0 to 5%

0.05%

0.1%

0 to 10%

0.1%

0.1%

0 to 20%

0.2%

0.1%

Model

OW-301/302

Optional: Solar powered and battery back-up

* Water Concentration. Contact Factory For Additional Range Options

SAFETY CERTIFICATION

ATEX: Sensor - x II 1G Ex ia IIB T4 (-20C<Ta<60C)

x II 2 G Ex d[ia] IIB T6 (-20C<Ta<60C)

DAS Enclosure -

Barrier Enclosure -

x II 2 G Ex d[ia] IIB + H2 T6 (-20C<Ta<50C)

CSA-US - Class 1, Division 1, Group C&D, T6

ROSTECHNADZOR (Russia, CIS), GOST-R, Metrology Pattern Approval


DATA OUTPUT/INPUT
Standard
Output Data:
Input Data:
User Communication:
Protocol:

Oil/water concentration, error status, and temperature standard.


Flow; 1 pulse (0-5 to 0-30 V <2KHz) or 1 analog (4-20 mA)
RS-232/422/485 Full Duplex
Modicon MODBUS: RS-232/422/485 ASCII or RTU mode; HART: 4-20mA or RS-232

Update Time:

1.0 sec

Display with four lines: %Water, Temperature, Total Oil, Total Water or Flow rates configurable
If customers flow meter input provided, Net Oil, Net Water, and Flow Rates are calculated.
Options
Pulse or Relay: 3-SPST relay isolated output (30V - .05a) - Selectable for totalizer or alarm

CAYMAN ISLAND: Agar Corporation, LTD - P.O. Box 10206 - Grand Cayman, BWI - KY1-1002 - Tel: (345) 945-5242 - [email protected]
USA
Agar Corporation
5150 Tacoma Drive
Houston, TX 77041
Tel: (832) 476-5100
Fax: (832) 476-5299
[email protected]

CANADA
Agar Canada Corp
Unit 406, 5723 10 St NE
Calgary, AB T2E 8W7
Tel: (403) 718-9880
Fax: (403) 450-8350
[email protected]

VENEZUELA
Agarcorp de Venezuela C.A.
77 Edif. 5 de Julio, Piso 4, Ofiicina
D-4, Sector Tierra Negra, Zona
Postal 4002, Maracaibo, Edo. Zulia
Tel: +58 261 324 5789
[email protected]

MALAYSIA
AgarCorp SDN. BHD.
168-1st Fl Main Rd Salak So
57100 Kuala Lumpur
Tel: 603-7980-7069
Fax: 603-7980-5369
[email protected]

ABU DHABI
Agar Corporation (ACAD)
1505, Three Sails Tower
Corniche, Khalidiya
Abu Dhabi, UAE
Tel/Fax: 971-2681-1779
[email protected]

INDONESIA
PT AgarCorp Indonesia
Jalan Teratai CB-17
Ciputat Baru, Ciputat
Tangerang 15413
Tel: 62 21 7409206
[email protected]

AGAR CORPORATION
www.agarcorp.com
ER No. 5485: ACI-A-7.2-DOC-007 Rev-00

You might also like