Inline Tech Unit
Inline Tech Unit
4958
Rev. A
LINER HANGER
TECHNICAL UNIT
Hanger Packers
12-01-04
Page 2 of 3
WARNING
Use of Baker equipment contrary to
manufacturers specification may result in
property damage, serious injury or fatality.
Specification Guide
INLine Liner Hanger Specs
Liner
Casing Weight Hanging
Casing
Weight
Capacity
Range
Size
Range
(lb)
(lb/ft)
(lb/ft)
11-3/4"- 11-7/8" 60-65 and 71.8 13-3/8" - 13-5/8" 68-72 and 88.2 1,000,000
* Note: 2000 psi and 2500 psi setting pressures can be provided on request.
Based upon 125Ksi MYS Body.
Liner
Size
Setting
Pressure
psi
1,500*
Bypass Area
Casing Size
13-3/8" 68.0 lb/ft
13-3/8" 72.0 lb/ft
13-5/8" 88.2 lb/ft
Set (in.2)
5.076
4.248
4.79
Unset (in.2)
5.494
4.172
4.714
Casing
Weight
Range
(lb/ft)
Differential
Pressure
Rating
(psi)
Setting
Force
Required
for Packer
(lb)
No. of
Shear
Pins
Shear Pin
Size
Material No.
of Shear Pins
5,000
60,000
10
7/16"-14 x 7/16"
HWW-GE1F-0FB
11.000"
(H07-81736-00)
Other Specifications
Max OD
Body ID
(in.)
(in.)
12.13
10.686
400oF can be provided on request.
Operation
The INLine Liner Hanger Packer System is
operated just as if you were running a conventional ZXP/Hydraulic Set Liner Hanger system.
The running tool that is used is the 2RH Running Tool which has a right hand release mechanism. When the tool is at setting depth, drop
ball and pressure slightly over the setting pressure of the hanger which will be set for 1,500 psi
(2,000, or 2,500 psi on request). When the rupture disk ruptures, the small piston will move out
and make contact with the connecting rod. The
connecting rod is keeping a snap ring, that is
Packoff Rating
(psi)
5,000
Temperature Rating
(oF)
250
12.13
11.5
10.686
12.13
12.095
12.13
12.085
12.13