Avon St53 Data
Avon St53 Data
Avon St53 Data
SERIES
The Multi-Role Respiratory
Protection System
ST53
SERIES
The Multi-Role Respiratory
Protection System
Technical Data
Breathing performance in SCBA mode Breathing performance in ST PAPR mode
Breathing rate 103 liters per minute with mask pressure above ambient
Environmental range The operating range is -30C to +60C Breathing rate 125 - 165 liters per minute
End of cylinder air Able to sustain positive pressure down to 10 bar cylinder pressure
Live agent permeation performance (Data validated by ECBC, Edgewood Chemical Biological Center)
Requirements Actual NIOSH CBRN Typical
Test agent requirements performance
Max Peak Max Cumulative Max Peak Max Cumulative
Challenge chemical
(mg/m3) (mg-min/m3) (mg/m3) (mg-min/m3) Mustard (HD) 6 Hours >6 Hours
Sarin (GB) 0.6 6 0.004 0.203
Sarin (GB) 6 Hours >6 Hours
Mustard (HD) 0.087 6 0.005 0.8
Materials used
Harness on ST53 SCBA Kevlar webbing with stainless steel and nylon hardware
Harness on ST53SD SCBA Nylon Cordura
Backplate Glass reinforced polycarbonate
Cylinder valve Anodized Aluminum
ST-PAPR GE Noryl with a 10% glass fill
Weight for ST53 units (based on empty cylinders) Weight for ST53SD units (based on empty cylinders)
ST53 (excluding cylinder and mask) 6.6 lbs
Carbon fiber fully wrapped, 2216 psi, 30 minute 7.75 lbs ST53SD 11 cu.ft (includes cylinder but no mask) 5.2 lbs
ST53
microphone can be connected via the Electronic Communication Port (ECP).
Additional external communication systems can be attached via the ECP using an
The standard ST53 with full back frame appropriate lead.
OPTION
offers 30, 45 and 60 minute lightweight
carbon cylinder options
A
Cylinder Valve
The ST53 includes a nickel-plated
ST53SD
The Multi-Role Respiratory Protection System
ST53
other personal equipment. The ST- PAPR has a remote on/off switch located
OPTION on the mask hose connector enabling the With the option to mount on either side of the mask, it is unobtrusive and allows
The CDV is attached to the mask via the stan- ST- PAPR to be easily switched on and off.
dard 40mm thread connection. C A speed selector provides a high flow rate up to 165 liters per minute with
OPTION excellent integration with weapons and other personal equipment.
The CDV is attached to the mask via the standard 40mm thread connection.
Cylinder Options
Free air Approximate
a minimum flow rate of 125 Liters per minute at the lowest setting.
D Can be fitted with ST PAPR in back mounted configuration.
volume duration Lithium Sulphur Dioxide battery option with a minimum 7 hour battery life.
2216 psi, carbon wrapped 45 cu. ft. 30 minutes Lithium Ion rechargeable battery option with a minimum 6 hour battery
Free air Approximate
4500 psi, carbon wrapped 45 cu. ft. 30 minutes
life. Cylinder Options
volume duration
4500 psi, carbon wrapped 45 cu. ft. 45 minutes With the ST - PAPR the integrated CDV enables the user to switch instantly 11 cu. ft. carbon wrapped, 4500 psi 11 cu. ft 7 minutes
4500 psi, carbon wrapped 45 cu. ft. 60 minutes +
from powered air to positive pressure SCBA mode when required.
17 cu. ft. carbon wrapped, 4500 psi 17 cu.ft 12 minutes
Note: These are approximate durations that are based on MIOSH breathing rates of 40 liters per Incorporates two 40mm standard NATO thread filters. Note: These are approximate durations that are based on NIOSH breathing rates of 40 liters per minute.
minute.