Product Catalogue
INDEX
6
PRODUCT RANGE
ALL OUR PRODUCTS ARE CERTIFIED ACCORDING
TO INTERNATIONAL STANDARDS
SOLAR inverters
49
79
103
113
PV-DIESEL SOLUTIONS
121
Accessories
135
139
145
REFERENCES
This catalogue has been translated into several languages. In case of discrepancy between them, the English text shall prevail.
Every technical data and/or specification included in this catalogue is for indicative purposes only and is subject to change. INGETEAM reserves the right to change, modify, alter or update any product or
services presented on this catalogue at any time and without prior notice to its customers.
MORE THAN 42 GW
SUPPLIED TO THE
RENEWABLE ENERGY
MARKET WORLDWIDE
USA
MEXICO
Energy
PANAMA
Industry
Marine
CHILE
Traction
Basic
Technologies
Services
SAUDI UAE
ROMANIA
ARABIA
CZECH
REPUBLIC GREECE TURKEY
POLAND
ITALY
JORDAN
GERMANY
UNITED KINGDOM
FRANCE
SPAIN
JAPAN
Morocco
CHINA
INDIA
PHILIPPINES
Egypt
BRAZIL
AUSTRALIA
URUGUAY
SOUTH AFRICA
Ingeteam Branch
Service
WE DESIGN AND
MANUFACTURE A WIDE
RANGE OF INVERTERS
MORE THAN 5 GW SUPPLIED TO THE
SOLAR PV MARKET WORLDWIDE
PRODUCT RANGE
ALL OUR PRODUCTS ARE CERTIFIED ACCORDING TO
INTERNATIONAL STANDARDS
Solar inverters
String Inverters
1Play TL U M
3Play TL
3Play TL M
3Play TL U M
2.5 - 6 kW
2.8 - 6 kW
10 - 33 kW
10 - 40 kW
24 - 40 kW
p. 10
p. 14
p. 18
p. 22
p. 26
1Play TL M
PowerStation SHE 22
PowerStation CON 20
p. 50
p. 54
p. 58
STORAGE 1Play
STORAGE Power
3 - 6 kW
p. 82
p. 90
p. 94
p. 98
Central Inverters
PowerMax B Series
PowerMax U B Series
PowerMax X Series
PowerMax M Series
p. 32
p. 36
p. 40
p. 44
p. 62
p. 68
p. 72
Diesel-PV Solutions
Accessories
EMS Manager
EMS Plant
Controller
Diesel-PV
Solutions
String Control
p. 106
p. 108
p. 112
p. 122
SOLAR inverters
TL M Series
10
Easy to install
The INGECON SUN 1Play TL M inverters feature fast-on connectors on the
DC side (type 4) and the AC side for a
fast and easy connection to the system.
Every country-specific configuration
and language can be easily selected
from the inverter screen. Moreover, the
INGECON SUN 1Play TL M inverters
are compatible with all the PV module
technologies on the market.
Protections
Reverse polarity.
Input and output overvoltages
with type 3 surge arresters.
Output shortcircuits and overloads.
Anti-islanding with automatic
disconnection.
Insulation failures.
Main features
Optional accessories
Compact design.
DC switch.
1Play TL M
MPP1
AC output
for grid
connection
Filter
PV input
PV input
MPP2
Optional
11
Solar inverters
1Play TL M Series
1Play TL M Series
2.5TL M
3TL M
3.2 - 4 kWp
3.3TL M
3.68TL M
Input (DC)
Recommended PV array power range(1)
Voltage range MPP1(2)
125 - 750 V
90 - 750 V
Maximum voltage(4)
850 V
11 / 11 A
1/1
MPPT
Output (AC)
Rated power
Max. temperature at rated power(6)
2.5 kW
3 kW
3.3 kW
3.68 kW
60 C
55 C
52 C
50 C
Maximum current
16 A
Rated voltage
230 V
Voltage range
122 - 265 V
Frequency
50 / 60 Hz
Power Factor
Power Factor adjustable
1
Yes. Smax=2.5 kVA
THD
<3%
Efficiency
Maximum efficiency
97.6%
97.7%
97.7%
97.8%
Euroefficiency
97.3%
97.4%
97.4%
97.5%
General Information
Refrigeration system
Air convection
Stand-by consumption(7)
<10 W
Consumption at night
0W
Ambient temperature
-25 C to +65 C
0 - 100%
Protection class
IP65
Marking
Notes: (1) Depending on the type of installation and geographical location (2) The output power will
be conditioned by the voltage and current configuration selected at each input (3) To drop to 90 V,
the other input must be at least at 125 V (4) Must not be exceeded under any circumstances.
Consider the voltage increase of the Voc at low temperatures (5) Optionally, the DC inputs could
be duplicated (6) For each C of increase, the output power will be reduced at the rate of 1.8%
(7)
Consumption from PV field (8) Related only inverters up to 16 A.
Efficiency (%)
CE
0.33
0.66
0.99
1.32
1.65
1.98
Power (kW)
470
36
0
18
12
Vdc = 680 V
100
98
95
93
90
88
85
83
80
78
75
2.31
2.64
2.97
3.3
4.6TL M
5TL M
6TL M
5.2 - 6 kWp
6.3 - 7 kWp
Input (DC)
Recommended PV array power range(1)
Voltage range MPP1(2)
125 - 750 V
90 - 750 V
Maximum voltage(4)
850 V
11 / 11 A
1/1
MPPT
Output (AC)
Rated power
Max. temperature at rated power(6)
4.6 kW
5 kW
6 kW
58 C
55 C
45 C
Maximum current
26.2 A
Rated voltage
230 V
Voltage range
122 - 265 V
Frequency
50 / 60 Hz
Power Factor
Power Factor adjustable
1
Yes. Smax=4.6 kVA
THD
<3%
Efficiency
Maximum efficiency
97.9%
98%
98%
Euroefficiency
97.5%
97.6%
97.6%
General Information
Refrigeration system
Air convection
Stand-by consumption(7)
<10 W
Consumption at night
0W
Ambient temperature
-25 C to +65 C
0 - 100%
Protection class
IP65
Marking
EMC & Security standards
Grid connection standards
CE
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, EN 62109-1, EN 62109-2, IEC62103,
EN 50178, FCC Part 15, AS3100
RD1699/2011, DIN V VDE V 0126-1-1, EN 50438, CEI 0-21, VDE-AR-N 4105:2011-08, G59/2, G83/2(8), P.O.12.3, AS4777.2, AS4777.3, IEC 62116,
IEC 61727, UNE 206007-1, ABNT NBR 16149, ABNT NBR 16150, South African Grid code, Chilean Grid Code, Romanian Grid Code,
Ecuadorian Grid Code, Peruvian Grid code, IEEE 929, Thailand MEA & PEA requirements, DEWA (Dubai) Grid Code, Jordan Grid Code
Efficiency (%)
Notes: (1) Depending on the type of installation and geographical location (2) The output power will
be conditioned by the voltage and current configuration selected at each input (3) To drop to 90 V,
the other input must be at least at 125 V (4) Must not be exceeded under any circumstances.
Consider the voltage increase of the Voc at low temperatures (5) Optionally, the DC inputs could
be duplicated (6) For each C of increase, the output power will be reduced at the rate of 1.8%
(7)
Consumption from PV field (8) Related only inverters up to 16 A.
Vdc = 680 V
100
98
95
93
90
88
85
83
80
78
75
0
0.5
1.5
2.5
3.5
4.5
Power (kW)
470
36
0
18
13
Solar inverters
1Play TL M Series
TL U M Series
UL 1741
COMPLIANT
14
use. These inverters feature an internal datalogger for several months data
storage, accessible from a PC. Every inverter can be accessed from either a
remote PC or on-site from the inverter
front touch keypad through its LCD
screen. The display also features a
number of LEDs to indicate the inverter
operating status. These LED indicators
light up whenever any incident is detected, thereby simplifying and facilitating equipment maintenance tasks.
Firmware updating
The INGECON SUN 1Play TL U M inverters allow the user to perform the
firmware (FW) updating himself. It is as
easy as to download the latest version
of the firmware from the Ingeteam website: www.ingeteam.com, and update it
using a simple SD memory card. These
photovoltaic inverters feature a SD input
slit to facilitate the firmware updating
by the user.
15
Solar inverters
1Play TL U M Series
TL U M Series
Monitoring and communication
The internal operating variables and
the internal datalogger can be monitored through a number of media such
as USB communications, supplied as
standard. Also, RS-485, Ethernet, Wi-Fi,
and GSM / GPRS communications
are available upon demand. Included
at no extra cost are the INGECON
SUN Manager, INGECON SUN
Monitor and its Smartphone version
Web Monitor -available on the App
Store- for monitoring and recording
the inverter data over the Internet.
Able to withstand extreme conditions
The INGECON SUN 1Play TL U M inverter housing is suitable for outdoor
use (NEMA 4). Likewise, it can be used
under extreme atmospheric conditions
with temperature ranges from -13 F to
+149 F, although its main cooling system is natural air convection.
SiC technology
This solar inverter presents silicon carbide (SiC) components. SiC technology allows higher efficiency levels and
also a more reliable, light and compact
equipment.
MAIN FEATURES
Optional accessories
USB communications.
Two digital inputs as standard.
Self-consumption kit.
LCD Display.
Easy maintenance.
Protections
Reverse polarity.
Compact design.
Insulation failures.
1Play TL U M
L
PV input
MPP1
AC output
for grid
connection
Filter
AFCI
MPP2
PV input
Combiner Box
(optional)
Combiner Box
The Combiner Box is supplied with two
inputs per MPPT, DC switch.
Inverter
Combiner Box
4 lbs
10.4"
DC switch.
2 MPPTs (2 inputs per MPPT).
Fuses not required, according to
NEC 2014 690.9.
16
4.7"
6. 3
5"
2.8TL U M
3.3TL U M
2.8 - 3.6 kW
3.4 - 4.3 kW
5TL U M
6TL U M
5.1 - 6.5 kW
6.1 - 7.8 kW
5 kW
6 kW
Input (DC)
Recommended PV array power range(1)
Voltage range MPP(2)
125 - 750 V
90 - 750 V
Maximum voltage(4)
850 V
11 / 11 A
1/1
MPPT
Output (AC)
Rated power
2.8 kW
3.3 kW
113 F
16 A
16 A
26.2 A
26.2 A
208 / 240 V
208 / 240 V
208 / 240 V
240 V
Frequency
60 Hz
Power Factor
Power Factor adjustable
1
Yes. Smax=2.8 kVA
THD
<3%
Efficiency
Maximum efficiency
CEC - Weighted efficiency
98.6%
98.5%
98.4%
98.9%
97%
97.5%
97.5%
98%
General Information
Refrigeration system
Forced ventilation
Stand-by consumption(6)
<10 W
Consumption at night
0W
Ambient temperature
-13 F to 149 F
0 - 100%
Protection class
NEMA 4
DC AFCI
Marking
CE, ETL
Efficiency (%)
Notes: (1) Depending on the type of installation and geographical location (2) The output power
will be conditioned by the voltage and current configuration selected at each input (3) To drop
to 90 V, the other input must be at least at 125 V (4) Must not be exceeded under any
circumstances. Consider the voltage increase of the Voc at low temperatures (5) The output
power will be reduced at the rate of 1% for each 1 F of increase (6) Consumption from PV field.
Vdc = 680 V
100
98
95
93
90
88
85
83
80
78
75
0
Power (kW)
18.5
5TL U M / 6TL U M
46.3 pounds
14
.17
9
7.0
17
Solar inverters
1Play TL U M Series
TL Series
19
Solar inverters
3Play TL Series
TL Series
Different versions to choose from
In order to satisfy its clients needs, Ingeteam has created different versions
for the INGECON SUN 3Play TL family:
Main features
Protections
MPPT system.
Reverse polarity.
S: Standard version
Digital inputs.
Insulation faults.
P: Premium version
3Play TL P+ version
Optional accesories
Display-configurable potential-free
contact, to indicate insulation fault or
grid connection.
On the other hand, the Premium version includes two options for DC connection: conventional terminal blocks
or fused and monitored PV connectors.
Benefits
Easy maintenance.
(33 kW)
Inverter
L1
L1
L2
Filter
PV input
L3
L2
L3
AC output for
connection to
the grid
Optional
N
Optional
Optional
735
70
26
20
28TL / 33TL
51.5 kg.
10TL
15TL
20TL
28TL
33TL
10.3 - 13.4 kW
15.5 - 20.1 kW
20.6 - 26.8 kW
28.9 - 37.5 kW
34 - 45 kW
52 A
61 A
Input (DC)
Recommended PV array power range(1)
Voltage range MPP(2)
560 - 820 V
560 V
Maximum voltage(3)
1,000 V
Maximum current(4)
19 A
28 A
37 A
1
5
MPPT
Output (AC)
Rated power
10 kW
15 kW
20 kW
28 kW
33 kW
55 C
55 C
55 C
51 C
51 C
Maximum current
15 A
22 A
29 A
41 A
48 A
304 - 528 V
304 - 528 V
98.3%
98.3%
400 m3/h
400 m3/h
Rated voltage
400 V
Voltage range
187 - 528 V
187 - 528 V
187 - 528 V
Frecuency
50 / 60 Hz
Power Factor
THD
<3%
Efficiency
Maximum efficiency
98.5%
Euroefficiency
98.3%
98.4%
200 m3/h
200 m3/h
98.3%
General Information
Refrigeration system
Forced ventilation
Air flow
200 m3/h
Stand-by consumption(7)
10 W
Consumption at night
1W
Ambient temperature
-25 C to 65 C
0 - 100%
Protection class
IP65
Marking
CE
Versions available
S
Standard version
S+
P
Premium version
P+
Standard version
S
Premium version
S+
P+
*
Terminal blocks
( )
( )
PV connectors
DC switch
DC surge arresters, type 2
DC and AC surge arresters, type 3
DC fuses
Current measuring kit
Terminal blocks not available for the Premium versions of the INGECON SUN 28TL and 33TL inverters.
Notes: (1) Depending on the type of installation and geographical location (2) Vmpp,min =
560 V when Vac = 400 V. Otherwise: Vmpp,min = 1.4 x Vac (3) Must not be exceeded
under any circumstances. Consider the voltage increase of the Voc at low temperatures
(4)
The maximum current per PV connector is 11 A for Premium versions (5) Branch plugs
and sockets available to connect two cables to each input (6) For each C of increase,
the output power will be reduced at the rate of 1.8% (7) Consumption from PV field
(8)
Related only to inverters up to 16 A.
(*)
Vdc = 600 V
99
98
97
96
95
94
93
92
91
90
0
10
12
14
16
18
20
Power (kW)
21
Solar inverters
3Play TL Series
TL M Series
22
Main features
Protections
Double-MPPT system.
Reverse polarity.
Digital inputs.
Insulation faults.
P: Premium version
3Play TL M P+ version
Display-configurable potential-free
contact, to indicate insulation fault
or grid connection.
Self-consumption kit.
Benefits
Easy maintenance.
Optional accesories
LCD display.
On the other hand, the Premium version includes two options for DC connection: conventional terminal blocks
or fused and monitored PV connectors.
Compact design.
Language, rated voltage and
Country Code, rated voltage
configurable by display.
(20 kW)
Inverter
L1
PV input
MPPT1
L1
Filter
L2
L2
L3
L3
MPPT2
PV input
AC output for
connection to
the grid
Optional
Optional
Optional
735
70
26
23
Solar inverters
3Play TL M Series
3Play TL M Series
400 Vac
10TL M
15TL M
20TL M
28TL M
33TL M
10.3 - 13.4 kW
15.5 - 20.1 kW
20.6 - 26.8 kW
28.9 - 37.5 kW
34 - 45 kW
40 / 40 A
40 / 40 A
5/5
5/5
Input (DC)
Recommended PV array power range(1)
Voltage range MPP1(2)
200 - 820 V
200 - 820 V
Maximum voltage(3)
1,000 V
30 / 20 A
30 / 20 A
30 / 20 A
1/1
3/2
3/2
3/2
MPPT
Output (AC)
Rated power
10 kW
15 kW
20 kW
28 kW
33 kW
55 C
55 C
55 C
51 C
51 C
Maximum current
15 A
22 A
29 A
41 A
48 A
304 - 528 V
304 - 528 V
400 m3/h
400 m3/h
Rated voltage
400 V
Voltage range
187 - 528 V
187 - 528 V
187 - 528 V
Frecuency
50 / 60 Hz
Power Factor
THD
<3%
Efficiency
Maximum efficiency
98.5%
Euroefficiency
98.3%
General Information
Refrigeration system
Forced ventilation
Air flow
200 m3/h
200 m3/h
200 m3/h
Stand-by consumption(7)
10 W
Consumption at night
1W
Ambient temperature
-25 C to 65 C
0 - 100%
Protection class
IP65
Marking
CE
Versions available
S
Standard version
S+
P
Premium version
P+
Standard version
S
Premium version
S+
P+
*
Terminal blocks
( )
( )
PV connectors
DC switch
DC surge arresters, type 2
DC and AC surge arresters, type 3
DC fuses
Current measuring kit
Terminal blocks not available for the Premium versions of the INGECON SUN 28TL M, 33TL M and 40TL M480 inverters.
Notes: (1) Depending on the type of installation and geographical location (2) The output
power will be conditioned by the voltage and current configuration selected at each
input (3) Must not be exceeded under any circumstances. Consider the voltage increase
of the Voc at low temperatures (4) The maximum current per PV connector is 11 A for
Premium versions (5) Branch plugs and sockets available to connect two cables to each
input (6) For each C of increase, the output power will be reduced at the rate of 1.8%
(7)
Consumption from PV field (8) Related only to inverters up to 16 A.
(*)
12
16
20
Power (kW)
24
Vdc = 720 V
99
98
97
96
95
94
93
92
91
90
24
28
32
36
24TL M480
40TL M480
Input (DC)
Recommended PV array power range(1)
24.7 - 32.2 kW
41.2 - 53.6 kW
200 - 820 V
200 - 820 V
Maximum voltage(3)
1,000 V
30 / 20 A
40 / 40 A
1/1
3/2
5/5
MPPT
Output (AC)
Rated power
24 kW
40 kW
55 C
51 C
Maximum current
29 A
48 A
Rated voltage
480 V
Voltage range
187 - 528 V
304 - 528 V
Frecuency
50 / 60 Hz
Power Factor
1
Yes. Smax=24 kVA;
Qmax=24 kVAR
THD
<3%
Efficiency
Maximum efficiency
98.5%
Euroefficiency
98.3%
General Information
Refrigeration system
Forced ventilation
Air flow
200 m3/h
400 m3/h
Stand-by consumption(7)
10 W
Consumption at night
1W
Ambient temperature
-25 C to 65 C
0 - 100%
Protection class
IP65
Marking
CE
Versions available
S
Standard version
S+
P
Premium version
P+
Standard version
S
Premium version
S+
P+
*
Terminal blocks
( )
( )
PV connectors
DC switch
DC surge arresters, type 2
DC and AC surge arresters, type 3
DC fuses
Current measuring kit
Terminal blocks not available for the Premium versions of the INGECON SUN 28TL M, 33TL M and 40TL M480 inverters.
Notes: (1) Depending on the type of installation and geographical location (2) The output
power will be conditioned by the voltage and current configuration selected at each
input (3) Must not be exceeded under any circumstances. Consider the voltage increase
of the Voc at low temperatures (4) The maximum current per PV connector is 11 A for
Premium versions (5) Branch plugs and sockets available to connect two cables to each
input (6) For each C of increase, the output power will be reduced at the rate of 1.8%
(7)
Consumption from PV field (8) Related only to inverters up to 16 A.
(*)
Vdc = 72 0 V
99
98
97
96
95
94
93
92
91
90
0
12
16
20
24
28
32
36
40
Power (kW)
25
Solar inverters
480 Vac
3Play TL M Series
TL U M Series
UL 1741
COMPLIANT
Rugged design
Steel casing, especially designed for indoor and outdoor applications (NEMA
4). It with stands extreme temperatures.
The 3Play inverters have been designed
to guarantee a long life expectancy.
Software included
Included at no extra cost are the INGECON SUN Manager, INGECON
SUN Monitor and its smartphone version Web Monitor for monitoring and
recording the inverter data over the internet. In addition, users can download
the latest version of the firmware from
the Ingeteam website www.ingeteam.
com, and update it using a simple SD
memory card. RS-485 communications are supplied as standard.
Ease of maintenance
Internal datalogger for up to 3 months
data storage. Control either from a remote PC or on-site from the inverter
front keypad. Status and alarm LED
indicators. LCD screen. Integrated DC
arc-fault circuit interruption system.
Easy to operate
The INGECON SUN 3Play TL U M inverters feature a LCD screen for the
26
27
Solar inverters
3Play TL U M Series
TL U M Series
A versatile equipment
The INGECON SUN 3Play TL U M
inverters integrate an arc-fault circuit
interruption system.
The standard inverter features a double
MPPT input with terminal blocks. It also
integrates DC and AC surge arresters,
type 3. Optionally, it can be supplied
with DC surge arresters, type 2.
MAIN FEATURES
PROTECTIONS
Reverse polarity.
Double-MPPT System.
Insulation faults.
LCD display.
RS-485 communications supplied as
standard.
OPTIONAL ACCESSORIES
Display-configurable potential-free
contact, to indicate insulation fault or
grid connection.
Plug & Play technology.
Suitable for indoor and outdoor
installations (NEMA 4).
High temperature performance. Rated
power up to 131 F (55 C) for the 24 kW
inverters.
Language, rated voltage and Country
Code configurable by display.
AFCI
MPPT 1
PV input
L1
Filter
L2
AC output
for connection
to the grid
MPPT 2
L3
AFCI
Optional
Combiner Box
The Combiner Box is supplied with four
or six inputs per MPPT with fuses on
each pole and a DC switch. It can be
located immediately under the PV inverter or in a different place.
Inverter
Combiner Box
15 Ibs
23
PV input
DC switch.
2 MPPTs (4 inputs / MPPT for the 24 kW models,
and 6 inputs / MPPT for the 40 kW model).
4 fuses per pole for the 24 kW models and 6 fuses
per pole for the 40 kW model.
Max. short-circuit current per input: 12 A.
Max. current per MPPT: 30 A for the 24 kW models,
and 40 A for the 40 kW model.
28
5
14.
24TL U M480
40TL U M480
Input (DC)
Recommended PV array power range(1)
41.2 - 53.6 kW
24.7 - 32.2 kW
200 - 820 V
200 - 820 V
Maximum voltage(3)
1,000 V
40 / 40 A
27 / 27 A
1/1
MPPT
Output (AC)
Rated power
Temperature at rated power
(4)
Maximum current
24 kW
40 kW
131 F
124 F
48 A
29 A
Rated voltage
480 V
Frequency
60 Hz
Power Factor(5)
Power Factor adjustable
1
Yes. Smax=40 kVA; Qmax=24 kVAR
THD
<3%
Efficiency
Maximum efficiency
98.5%
98%
General Information
Refrigeration system
Forced ventilation
Air flow
400 m3/h
200 m3/h
10 W
Stand-by consumption(6)
Consumption at night
1W
Ambient temperature
-13 F to 149 F
0 - 100%
Protection class
NEMA 4
DC AFCI
Marking
CE, ETL
Notes: (1) Depending on the type of installation and geographical location (2) The
output power will be conditioned by the voltage and current configuration selected
at each input (3) Must not be exceeded under any circumstances. Consider the
voltage increase of the Voc at low temperatures (4) The output power will be reduced
at the rate of 1% for each 1 F of increase (5) For Pout>25% of the rated power
(6)
Consumption from PV field.
Vdc = 720 V
99
98
97
96
95
94
93
92
91
90
0
12
16
20
24
28
32
36
40
Power (kW)
28
24TL U M / 40TL U M
129 / 137.8 Ibs
29
.5
10
29
Solar inverters
3Play TL U M Series
components, such as the IGBTs, ensuring that the rated power can be delivered up to an operating temperature of
50 C (122 F).
Working in combination with the INGECON SUN EMS Plant Controller, the
inverters are able to control the active
power delivered to the grid.
Grid support
This family of central inverters performs
grid support functions and complies
with the grid connection requirements
for countries throughout the world, contributing to the quality and stability of
the electricity system.
Model versatility
These central inverters can be supplied
in a number of topologies, making them
suitable for all kinds of projects. The inverters are available in three configurations: monoblock (B series), master-slave
(X series) and multi-MPPT (M series).
Further options include indoor or outdoor models, and inverters with an integrated DC-AC cabinet or without the
AC lines.
B Series
X Series
M Series
30
Jasper PV Plant (South Africa). 75 MW PV plant with INGECON SUN PowerMax inverters
31
Solar inverters
PowerMax
B Series
Maximum protection
These three phase inverters are equipped
with a motorized DC switch to decouple
the PV generator from the inverter. Optionally, these inverters can be supplied
with an AC circuit breaker with door control, in addition to fuses, grounding kit
and input current monitoring.
Enhanced functionality
This new INGECON SUN PowerMax
range features a revamped, improved
enclosure which, together with its innovative air cooling system, makes it possible to increase the ambient operating
temperature to deliver its rated power
up to 50 C.
32
Long-lasting design
The inverters have been designed to
guarantee a long life expectancy, as
demonstrated by the stress tests they
are subjected to. Standard 5 year warranty, extendable for up to 25 years.
Grid support
The INGECON SUN PowerMax B Series has been designed to comply with
the grid connection requirements in
different countries, contributing to the
quality and stability of the electric system. These inverters therefore feature a
low voltage ride-through capability, and
can deliver reactive power and control
the active power delivered to the grid.
Ease of maintenance
All the elements can be removed or replaced directly from the inverters front
side, thanks to its new design.
Easy to operate
The INGECON SUN PowerMax inverters feature an LCD screen for the simple and convenient monitoring of the
inverter status and a range of internal
variables.
The display also includes a number of
LEDs to show the inverter operating status with warning lights to indicate any
PROTECTIONS
OPTIONAL ACCESSORIES
DC Reverse polarity.
Grounding kit.
Up to 15 pairs of fuse-holders.
Enhanced performance.
DC fuses.
Lightweight spares.
PowerMax B Series
+15
...
L1
L2
L3
Filter
+3
+2
+1
-1
-2
-3
Inverter
AC output for
connection to a
MV network
Optional
...
-15
Optional
2, 8
2,010
20
88
20
89
33
Solar inverters
PowerMax B Series
PowerMax
B Series
830TL B300
1000TL B360
1070TL B385
1110TL B400
1140TL B410
1165TL B420
440 - 820 V
524 - 820 V
560 - 820 V
580 - 820 V
595 - 820 V
610 - 820 V
Input (DC)
Recommended PV array power range(1)
Voltage Range MPP(2)
1,050 V
Maximum voltage(3)
Maximum current
2,000 A
1,00
0 Vdc
5 up to 15
Fuse dimensions
Type of connection
Power blocks
MPPT
Input protections
Overvoltage protections
DC switch
Other protections
Output (AC)
Power @35 C / @50 C(4)
300 V IT System
360 V IT System
385 V IT System
Frequency
400 V IT System
410 V IT System
420 V IT System
50 / 60 Hz
1
Power Factor(5)
Power Factor adjustable
1,600 A / 1,472 A
<3%
Output protections
Overvoltage protections
AC breaker
Anti-islanding protection
Other protections
Features
Maximum efficiency
98.7%
Euroefficiency
98.3%
98.9%
98.5%
98.5%
98.6%
98.5%
98.5%
2,500 VA
60 W
18 kWh
General Information
Ambient temperature
-20 C to +55 C
Protection class
Maximum altitude(8)
Cooling system
Air forced with temperature control (230 V phase + neutral power supply)
6,200 m3/h
Air flow
Acoustic emission
< 77 dB (A) at 1 m
Marking
CE
EN 61000-6-1, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, EN 62109-1, EN 62109-2, IEC62103, EN 50178, FCC Part 15, AS3100
IEC 62116, Arrt 23-04-2008, CEI 0-16 Ed. III, Terna A68, G59/2, BDEW-Mittelspannungsrichtlinie:2011, P.O.12.3,
South African Grid code (ver 2.6), Chilean Grid Code, Ecuadorian Grid Code, Peruan Grid code, Thailand PEA requirements, IEC61727,
UNE 206007-1, ABNT NBR 16149, ABNT NBR 16150, IEEE 1547, IEEE1547.1, GGC&CGC China, DEWA (Dubai) Grid code, Jordan Grid Code
Notes: (1) Depending on the type of installation and geographical location. Data for
STC conditions (2) Vmpp.min is for rated conditions (Vac=1 p.u. and Power Factor=1) (3) Consider the voltage increase of the Voc at low temperatures (4) For each
C of increase between 35 C and 50 C, the output power will be reduced at the
rate of 0.53%. Over 50 C, the output power will be reduced at the rate of 1.8% / C
(5)
For Pout >25% of the rated power (6) For Pout >25% of the rated power and voltage in
accordance with IEC 61000-3-4 (7) Consumption from PV field when there is PV power
available (8) Over 1,000 m temperature for rated power is reduced at the rate of 4.5
C for each 1,000 m. For installations beyond the maximum altitude, please contact
Ingeteams solar sales department.
100
200
300
400
500
600
700
Power (kVA)
34
Vdc = 650 V
100
98
96
94
92
90
88
86
84
82
800
900
B Series
1170TL B450
1400TL B540
1500TL B578
1560TL B600
1600TL B615
1640TL B630
660 - 1,300 V
786 - 1,300 V
840 - 1,300 V
870 - 1,300 V
889 - 1,300 V
915 - 1,300 V
Input (DC)
Recommended PV array power range(1)
Voltage Range MPP(2)
1,500 V
Maximum voltage(3)
Maximum current
2,000 A
1,50
0 Vdc
6 up to 15
Fuse dimensions
Type of connection
Power blocks
MPPT
Input protections
Overvoltage protections
DC switch
Other protections
Output (AC)
Power @25 C / @50 C(4)
450 V IT System
540 V IT System
578 V IT System
Frequency
615 V IT System
630 V IT System
600 V IT System
50 / 60 Hz
Power Factor(5)
Power Factor adjustable
1,500 A / 1,250 A
1
Yes. Smax=1,169 kVA
<3%
Output protections
Overvoltage protections
AC breaker
Anti-islanding protection
Other protections
Features
Maximum efficiency
98.9%
Euroefficiency
98.5%
2,500 VA
60 W
18 kWh
General Information
Ambient temperature
-20 C to +55 C
Protection class
Maximum altitude(8)
Cooling system
Air forced with temperature control (230 V phase + neutral power supply)
6,200 m3/h
Air flow
Acoustic emission
< 77 dB (A) at 1 m
Marking
CE
EN 61000-6-1, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, EN 62109-1, EN 62109-2, IEC62103, EN 50178, FCC Part 15, AS3100
IEC 62116, Arrt 23-04-2008, CEI 0-16 Ed. III, Terna A68, G59/2, BDEW-Mittelspannungsrichtlinie:2011, P.O.12.3,
South African Grid code (ver 2.6), Chilean Grid Code, Ecuadorian Grid Code, Peruan Grid code, Thailand PEA requirements, IEC61727,
UNE 206007-1, ABNT NBR 16149, ABNT NBR 16150, IEEE 1547, IEEE1547.1, GGC&CGC China, DEWA (Dubai) Grid code, Jordan Grid Code
Notes: (1) Depending on the type of installation and geographical location. Data for
STC conditions (2) Vmpp.min is for rated conditions (Vac=1 p.u. and Power Factor=1) (3) Consider the voltage increase of the Voc at low temperatures (4) For each
C of increase between 25 C and 50 C, the output power will be reduced at the
rate of 0.66%. Over 50 C, the output power will be reduced at the rate of 1.8% / C
(5)
For Pout >25% of the rated power (6) For Pout >25% of the rated power and voltage in
accordance with IEC 61000-3-4 (7) Consumption from PV field when there is PV power
available (8) Over 1,000 m temperature for rated power is reduced at the rate of 4.5
C for each 1,000 m. For installations beyond the maximum altitude, please contact
Ingeteams solar sales department.
Vdc = 1000 V
100
98
96
94
92
90
88
86
84
82
0
150
300
450
400
600
750
900
Power (kVA)
35
Solar inverters
PowerMax
U B Series
UL 1741
COMPLIANT
36
Maximum protection
These three phase inverters are
equipped with a motorized DC switch
to decouple the PV generator from the
inverter.
These inverters are supplied with an AC
circuit breaker. Optionally, they can be
supplied with DC fuses, grounding kit
and input current monitoring.
Maximum efficiency values
Through the use of innovative electronic conversion topologies, efficiency
values of up to 98.9% can be achieved.
A complete range of equipment for all
types of projects
Versions available:
Indoor inverters.
Outdoor inverters.
Symmetrical inverters, with the connection cabinet on the opposite side,
to make it possible to install two inverters facing each other, with a
common power supply point.
Enhanced functionality
This new INGECON SUN PowerMax
range features a revamped, improved
enclosure which, together with its innovative air cooling system, makes it possible to increase the ambient operating
temperature.
Long-lasting design
These inverters have been designed to
guarantee a long life expectancy. Standard 5 year warranty, extendable for up
to 25 years.
Grid support
The INGECON SUN PowerMax B
Series has been designed to comply
with the grid connection requirements
UL1741, IEEE1547 and RULE21, contributing to the quality and stability of
the electric system. These inverters
therefore feature a low voltage ridethrough capability, and can deliver
reactive power and control the active
power delivered to the grid.
Ease of maintenance
All the elements can be removed or replaced directly from the inverters front
side, thanks to its new design.
Easy to operate
The INGECON SUN PowerMax inverters feature an LCD screen for the simple and convenient monitoring of the
inverter status and a range of internal
variables. The display also includes a
number of LEDs to show the inverter ope-
rating status with warning lights to indicate any incidents. All this helps to simplify and facilitate maintenance tasks.
Monitoring and communication
Ethernet communications supplied as
standard. The following applications are
included at no extra cost: INGECON
SUN Manager, INGECON SUN Monitor and its Smartphone version Web
PROTECTIONS
OPTIONAL ACCESSORIES
DC Reverse polarity.
Grounding kit.
DC fuses.
Enhanced performance.
Lightweight spares.
AC circuit breaker.
PowerMax B Series
+15
...
L1
L2
L3
Filter
+3
+2
+1
-1
-2
-3
AC output for
connection to a
MV network
Inverter
M
...
-15
Optional
80
35
35
37
Solar inverters
PowerMax U B Series
PowerMax U
B Series
610TL U B220
830TL U B300
1000TL U B360
1110TL U B400
1165TL U B420
440 - 820 V
440 - 820 V
524 - 820 V
580 - 820 V
610 - 820 V
Input (DC)
Recommended PV array power range(1)
Voltage Range MPP(2)
1,050 V
Maximum voltage(3)
Maximum current
2,000 A
1,00
0 Vdc
5 up to 15
Fuse dimensions
Type of connection
Power blocks
MPPT
Input protections
Overvoltage protections
DC switch
Other protections
Output (AC)
Power @95 F / @122 F(4)
220 V IT System
300 V IT System
400 V IT System
420 V IT System
360 V IT System
Frequency
50 / 60 Hz
1
Power Factor(5)
Power Factor adjustable
1,600 A / 1,472 A
Output protections
Overvoltage protections
AC breaker
Anti-islanding protection
Other protections
Features
Maximum efficiency
98.9%
CEC
98.5%
2,500 VA
60 W
18 kWh
General Information
Ambient temperature
-4 F to +149 F
Protection class
Max. altitude(8)
9,842 ft
Cooling system
Air forced with temperature control (230 V phase + neutral power supply)
22 m3/s (7,200 m3/h)
Air flow
Acoustic emission
<77 dB
Marking
CE, ETL
UL1741, FCC Part 15, IEEE C37.90.1, IEEE C37.90.2
IEC 62116, UL1741, IEEE1547, IEEE1547.1, NEC CODE, Electric Rule 21: 2015
Notes: (1) Depending on the type of installation and geographical location. Data for
STC conditions (2) Vmpp.min is for rated conditions (Vac=1 p.u. and Power Factor=1)
(3)
Consider the voltage increase of the VOC at low temperatures (4) For each degree
of increase between 95 F and 122 F, the output power will be reduced at the rate of
0.38%. Over 122 F, the output power will be reduced at the rate of 1% for each degree
of increase (5) For Pout >25% of the rated power (6) For Pout >25% of the rated power and
voltage in accordance with IEC 61000-3-4 (7) Consumption from PV field when there
is PV power available (8) Over 3,300 ft, temperature for rated power is reduced at the
rate of 2.42 F for each 3,300 ft. For installations beyond the maximum altitude, please
contact Ingeteams solar sales department.
100
200
300
400
500
600
700
Power (kVA)
38
Vdc = 650 V
100
98
96
94
92
90
88
86
84
82
800
900
B Series
1600TL U B615
1640TL U B630
Input (DC)
Recommended PV array power range(1)
Voltage Range MPP(2)
660 - 1,300 V
786 - 1,300 V
840 - 1,300 V
870 - 1,300 V
889 - 1,300 V
915 - 1,300 V
1,500 V
Maximum voltage(3)
Maximum current
2,000 A
1,50
0 Vdc
6 up to 15
Fuse dimensions
Type of connection
Power blocks
MPPT
Input protections
Overvoltage protections
DC switch
Other protections
Output (AC)
Power @77 F / @122 F(4)
450 V IT System
540 V IT System
578 V IT System
Frequency
600 V IT System
615 V IT System
630 V IT System
50 / 60 Hz
1
Power Factor(5)
Power Factor adjustable
1,500 A / 1,250 A
Yes. Smax=1,502
kVA
Yes. Smax=1,559
kVA
<3%
Output protections
Overvoltage protections
AC breaker
Anti-islanding protection
Other protections
Features
98.9%
Maximum efficiency
98.5%
CEC
Max. consumption aux. services
2,500 VA
60 W
18 kWh
General Information
Ambient temperature
-4 F to +131 F
Protection class
Max. altitude(8)
6,562 ft (2,000 m)
Cooling system
Air forced with temperature control (230 V phase + neutral power supply)
66.77 ft3/s (6,200 m3/h)
Air flow
Acoustic emission
<77 dB
Marking
CE, ETL
UL1741, FCC Part 15, IEEE C37.90.1, IEEE C37.90.2
IEC 62116, UL1741, IEEE1547, IEEE1547.1, NEC CODE, Electric Rule 21: 2015
Notes: (1) Depending on the type of installation and geographical location. Data for
STC conditions (2) Vmpp.min is for rated conditions (Vac=1 p.u. and Power Factor=1)
(3)
Consider the voltage increase of the VOC at low temperatures (4) For each degree
of increase between 77 F and 122 F, the output power will be reduced at the rate of
0.37%. Over 122 F, the output power will be reduced at the rate of 1% for each degree
of increase (5) For Pout >25% of the rated power (6) For Pout >25% of the rated power and
voltage in accordance with IEC 61000-3-4 (7) Consumption from PV field when there
is PV power available (8) Over 3,300 ft, temperature for rated power is reduced at the
rate of 2.42 F for each 3,300 ft. For installations beyond the maximum altitude, please
contact Ingeteams solar sales department.
Vdc = 650 V
100
98
96
94
92
90
88
86
84
82
0
200
400
600
800
Power (kVA)
39
Solar inverters
PowerMax U
X Series
Indoor / Outdoor
Maximum protection
These three phase inverters are equipped with a motorized DC switch to decouple the PV generator from the inverter. Optionally, the inverters can be supplied with an AC circuit breaker with
door control, in addition to fuses, grounding kit and input current monitoring.
Filter
PowerMax X DCAC
+16
...
Inverter
+3
+2
+1
-1
-2
-3
L1
L2
L3
Filter
...
AC output for
connection to a
MV network
Optional
-16
Inverter
Optional
2, 3
10
92
40
2, 9
10
92
2 blocks Outdoor
1,500 kg.
3,5
10
2, 3
10
25
3 blocks Outdoor
2,050 kg.
0
1,0
4 blocks Outdoor
2,700 kg.
2,140
2,140
2,040
2,040
4 blocks Indoor
2,500 kg.
2,140
3 blocks Indoor
1,900 kg.
2,040
2 blocks Indoor
1,300 kg.
3,5
10
2, 9
10
0
1,0
0
1,0
X Series
2 Power blocks
380TL X300
400TL X320
440TL X345
460TL X360
500TL X400
535TL X420
437 - 820 V
468 - 820 V
502 - 820 V
528 - 820 V
581 - 820 V
611 - 820 V
Input (DC)
Recommended PV array power range(1)
Voltage Range MPP(2)
1,050 V
Maximum voltage(3)
Maximum current
900 A
Fuse dimensions
Type of connection
MPPT
Input protections
Overvoltage protections
DC switch
Other protections
Output (AC)
Power @30 C / @45 C (4)
415.7 kVA /
382.4 kVA
443.4 kVA /
407.9 kVA
478 kVA /
439.8 kVA
300 V IT System
320 V IT System
345 V IT System
498.8 kVA /
458.9 kVA
582 kVA /
535.4 kVA
400 V IT System
420 V IT System
800 A / 736 A
Rated voltage
Frequency
360 V IT System
50 / 60 Hz
1
Power Factor(5)
Power Factor adjustable
THD (Total Harmonic Distortion)
554.3 kVA /
509.9 kVA
<3%
(6)
Output protections
Overvoltage protections
AC breaker
Optional AC circuit breaker with door control, remote trip or motorized (only DCAC models)
Anti-islanding protection
Other protections
Features
Maximum efficiency
98.9%
99%
99.1%
99.1%
99.1%
99.1%
Euroefficiency
98.7%
98.8%
98.8%
98.8%
98.8%
98.8%
Stand-by consumption(7)
60 W
Consumption at night
60 W
General Information
Operating temperature
-20 C to +55 C
Protection class
IP20 / IP54
3,000 m
Maximum altitude(8)
Cooling system
Air forced with temperature control (230 V phase + neutral power supply)
Air flow
Acoustic emission
Marking
CE
EN 61000-6-1, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, EN 62109-1, EN 62109-2, IEC62103, EN 50178, FCC Part 15, AS3100
IEC 62116, Arrt 23-04-2008, CEI 0-16 Ed. III, Terna A68, G59/2, BDEW-Mittelspannungsrichtlinie:2011, P.O.12.3, South African Grid code (ver 2.6),
Chilean Grid Code, Romanian Grid Code, Ecuadorian Grid Code, Peruvian Grid code, IEEE 929, Thailand MEA & PEA requirements, IEC61727,
UNE 206007-1, ABNT NBR 16149, ABNT NBR 16150, IEEE 1547, IEEE1547.1, GGC&CGC China, DEWA (Dubai) Grid Code, Jordan Grid Code
Notes: (1) Depending on the type of installation and geographical location. Data for
STC conditions (2) Vmpp.min is for rated conditions (Vac=1 p.u. and Power Factor=1)
(3)
Consider the voltage increase of the Voc at low temperatures (4) For each C of
increase between 30 C and 45 C, the output power will be reduced at the rate of
0.53% / C. Over 45 C, the output power will be reduced at the rate of 1.8% / C
(5)
For Pout >25% of the rated power (6) For Pout >25% of the rated power and voltage in
accordance with IEC 61000-3-4 (7) Consumption from PV field (8) Over 1,000 m temperature for rated power is reduced at the rate of 4.5 C for each 1,000 m. For installations beyond the maximum altitude, please contact Ingeteams solar sales department.
Vdc = 550 V
100
98
96
94
92
90
88
86
84
82
0
100
200
300
400
500
Power (kVA)
41
Solar inverters
PowerMax
PowerMax
X Series
3 Power blocks
570TL X300
605TL X320
660TL X345
690TL X360
750TL X400
805TL X420
437 - 820 V
468 - 820 V
502 - 820 V
528 - 820 V
581 - 820 V
607 - 820 V
Input (DC)
Recommended PV array power range(1)
Voltage Range MPP(2)
1,050 V
Maximum voltage(3)
Maximum current
1,350 A
12 (extendable up to 16)
Fuse dimensions
Type of connection
MPPT
Input protections
Overvoltage protections
DC switch
Other protections
Output (AC)
Power @30 C / @45 C (4)
623.5 kVA /
573.7 kVA
665.1 kVA /
611.9 kVA
717.1 kVA /
659.7 kVA
300 V IT System
320 V IT System
345 V IT System
748.2 kVA /
688.4 kVA
873 kVA /
803.1 kVA
400 V IT System
420 V IT System
1,200 A / 1,104 A
Rated voltage
Frequency
360 V IT System
50 / 60 Hz
1
Power Factor(5)
Power Factor adjustable
THD (Total Harmonic Distortion)
831.4 kVA /
764.9 kVA
<3%
(6)
Output protections
Overvoltage protections
AC breaker
Optional AC circuit breaker with door control, remote trip or motorized (only DCAC models)
Anti-islanding protection
Other protections
Features
Maximum efficiency
98.9%
99%
99.1%
99.1%
99.1%
99.1%
Euroefficiency
98.7%
98.8%
98.9%
98.8%
98.7%
98.9%
Stand-by consumption(7)
90 W
Consumption at night
90 W
General Information
Operating temperature
-20 C to +55 C
Protection class
IP20 / IP54
3,000 m
Maximum altitude(8)
Cooling system
Air forced with temperature control (230 V phase + neutral power supply)
Air flow
Acoustic emission
Marking
CE
EN 61000-6-1, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, EN 62109-1, EN 62109-2, IEC62103, EN 50178, FCC Part 15, AS3100
IEC 62116, Arrt 23-04-2008, CEI 0-16 Ed. III, Terna A68, G59/2, BDEW-Mittelspannungsrichtlinie:2011, P.O.12.3, South African Grid code (ver 2.6),
Chilean Grid Code, Romanian Grid Code, Ecuadorian Grid Code, Peruvian Grid code, IEEE 929, Thailand MEA & PEA requirements, IEC61727,
UNE 206007-1, ABNT NBR 16149, ABNT NBR 16150, IEEE 1547, IEEE1547.1, GGC&CGC China, DEWA (Dubai) Grid Code, Jordan Grid Code
Notes: (1) Depending on the type of installation and geographical location. Data for
STC conditions (2) Vmpp.min is for rated conditions (Vac=1 p.u. and Power Factor=1)
(3)
Consider the voltage increase of the Voc at low temperatures (4) For each C of
increase between 30 C and 45 C, the output power will be reduced at the rate of
0.53% / C. Over 45 C, the output power will be reduced at the rate of 1.8% / C
(5)
For Pout >25% of the rated power (6) For Pout >25% of the rated power and voltage in
accordance with IEC 61000-3-4 (7) Consumption from PV field (8) Over 1,000 m temperature for rated power is reduced at the rate of 4.5 C for each 1,000 m. For installations beyond the maximum altitude, please contact Ingeteams solar sales department.
100
200
300
400
500
Power (kVA)
42
Vdc = 550 V
100
98
96
94
92
90
88
86
84
82
600
700
800
X Series
4 Power blocks
760TL X300
800TL X320
880TL X345
920TL X360
1000TL X400
1070TL X420
437 - 820 V
468 - 820 V
502 - 820 V
528 - 820 V
581 - 820 V
611 - 820 V
Input (DC)
Recommended PV array power range(1)
Voltage Range MPP(2)
1,050 V
Maximum voltage(3)
Maximum current
1,800 A
12 (extendable up to 16)
Fuse dimensions
Type of connection
MPPT
Input protections
Overvoltage protections
DC switch
Other protections
Output (AC)
Power @30 C / @45 C (4)
831.4 kVA /
764.9 kVA
886.8 kVA /
815.9 kVA
956.1 kVA /
879.6 kVA
300 V IT System
320 V IT System
345 V IT System
997.7 kVA /
917.8 kVA
1,163.9 kVA /
1,070.8 kVA
400 V IT System
420 V IT System
1,600 A / 1,472 A
Rated voltage
Frequency
360 V IT System
50 / 60 Hz
1
Power Factor(5)
Power Factor adjustable
THD (Total Harmonic Distortion)
1,108.5 kVA /
1,019.8 kVA
<3%
(6)
Output protections
Overvoltage protections
AC breaker
Optional AC circuit breaker with door control, remote trip or motorized (only DCAC models)
Anti-islanding protection
Other protections
Features
Maximum efficiency
98.9%
99%
99.1%
99.1%
99.1%
99.1%
Euroefficiency
98.8%
98.9%
98.9%
99%
99%
98.9%
Stand-by consumption(7)
120 W
Consumption at night
120 W
General Information
Operating temperature
-20 C to +55 C
Protection class
IP20 / IP54
3,000 m
Maximum altitude(8)
Cooling system
Air forced with temperature control (230 V phase + neutral power supply)
Air flow
Acoustic emission
Marking
CE
EN 61000-6-1, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, EN 62109-1, EN 62109-2, IEC62103, EN 50178, FCC Part 15, AS3100
IEC 62116, Arrt 23-04-2008, CEI 0-16 Ed. III, Terna A68, G59/2, BDEW-Mittelspannungsrichtlinie:2011, P.O.12.3, South African Grid code (ver 2.6),
Chilean Grid Code, Romanian Grid Code, Ecuadorian Grid Code, Peruvian Grid code, IEEE 929, Thailand MEA & PEA requirements, IEC61727,
UNE 206007-1, ABNT NBR 16149, ABNT NBR 16150, IEEE 1547, IEEE1547.1, GGC&CGC China, DEWA (Dubai) Grid Code, Jordan Grid Code
Notes: (1) Depending on the type of installation and geographical location. Data for STC
conditions (2) Vmpp.min is for rated conditions (Vac=1 p.u. and Power Factor=1) (3)
Consider the voltage increase of the Voc at low temperatures (4) For each C of increase between 30 C and 45 C, the output power will be reduced at the rate of 0.53% / C.
Over 45 C, the output power will be reduced at the rate of 1.8% / C (5) For Pout >25%
of the rated power (6) For Pout >25% of the rated power and voltage in accordance with
IEC 61000-3-4 (7) Consumption from PV field (8) Over 1,000 m temperature for rated
power is reduced at the rate of 4.5 C for each 1,000 m. For installations beyond the
maximum altitude, please contact Ingeteams solar sales department.
Vdc = 625 V
100
98
96
94
92
90
88
86
84
82
100
200
300
400
500
600
700
800
900
1000 1100
Power (kVA)
43
Solar inverters
PowerMax
M Series
Indoor / Outdoor
PowerMax M DCAC
Filter
PV Input
Module 1
Inverter
L1
L2
L3
AC output for
connection to
MV grid
Optional
Filter
PV Input
Module 4
Inverter
Optional
2, 3
10
92
44
2, 9
10
92
2 blocks Outdoor
1,500 kg.
3,5
10
2, 3
10
25
3 blocks Outdoor
2,050 kg.
0
1,0
4 blocks Outdoor
2,700 kg.
2,140
2,140
2,040
2,040
4 blocks Indoor
2,500 kg.
2,140
3 blocks Indoor
1,900 kg.
2,040
2 blocks Indoor
1,300 kg.
3,5
10
2, 9
10
0
1,0
0
1,0
M Series
2 Power blocks
380TL M300
400TL M320
440TL M345
460TL M360
500TL M400
535TL M420
437 - 820 V
468 - 820 V
502 - 820 V
528 - 820 V
581 - 820 V
611 - 820 V
Input (DC)
Recommended PV array power range(1)
Voltage Range MPP(2)
1,050 V
Maximum voltage(3)
Maximum current
900 A
Fuse dimensions(4)
Type of connection
MPPT(5)
Max. current at each input
Input protections
Overvoltage protections
DC switch
Other protections
Output (AC)
Power @30 C / @45 C (6)
415.7 kVA /
382.4 kVA
443.4 kVA /
407.9 kVA
478 kVA /
439.8 kVA
300 V IT System
320 V IT System
345 V IT System
498.8 kVA /
458.9 kVA
582 kVA /
535.4 kVA
400 V IT System
420 V IT System
800 A / 736 A
Rated voltage
Frequency
360 V IT System
50 / 60 Hz
1
Power Factor(7)
Power Factor adjustable
THD (Total Harmonic Distortion)
554.3 kVA /
509.9 kVA
<3%
(8)
Output protections
Overvoltage protections
AC breaker
Optional AC circuit breaker with door control, remote trip or motorized (only DCAC models)
Anti-islanding protection
Other protections
Features
Maximum efficiency
98.9%
99%
99.1%
99.1%
99.1%
99.1%
Euroefficiency
98.5%
98.6%
98.7%
98.7%
98.7%
98.6%
Stand-by consumption(9)
60 W
Consumption at night
60 W
General Information
Operating temperature
-20 C to +55 C
Protection class
IP20 / IP54
3,000 m
Maximum altitude(10)
Cooling system
Air forced with temperature control (230 V phase + neutral power supply)
Air flow
Acoustic emission
Marking
CE
EN 61000-6-1, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, EN 62109-1, EN 62109-2, IEC62103, EN 50178, FCC Part 15, AS3100
IEC 62116, Arrt 23-04-2008, CEI 0-16 Ed. III, Terna A68, G59/2, BDEW-Mittelspannungsrichtlinie:2011, P.O.12.3, South African Grid code (ver 2.6),
Chilean Grid Code, Romanian Grid Code, Ecuadorian Grid Code, Peruvian Grid code, IEEE 929, Thailand MEA & PEA requirements, IEC61727,
UNE 206007-1, ABNT NBR 16149, ABNT NBR 16150, IEEE 1547, IEEE1547.1, GGC&CGC China, DEWA (Dubai) Grid Code, Jordan Grid Code
Notes: (1) Depending on the type of installation and geographical location. Data
for STC conditions (2) Vmpp.min is for rated conditions (Vac=1 p.u. and Power
Factor=1) (3) Consider the voltage increase of the Voc at low temperatures
(4)
For other configurations, consult with Ingeteam (5) The MPPT connected to the
same transformer throught TL inverters must have the same voltage configuration
(6)
For each C of increase between 30 C and 45 C, the output power will be reduced
at the rate of 0.53% / C. Over 45 C, the output power will be reduced at the rate of
1.8% / C (7) For Pout >25% of the rated power (8) For Pout >25% of the rated power and
voltage in accordance with IEC 61000-3-4 (9) Consumption from PV field (10) Over
1,000 m temperature for rated power is reduced at the rate of 4.5 C for each 1,000
m. For installations beyond the maximum altitude, please contact Ingeteams solar
sales department.
Vdc = 650 V
100
98
96
94
92
90
88
86
84
82
0
100
200
300
400
500
Power (kVA)
45
Solar inverters
PowerMax
PowerMax
M Series
3 Power blocks
570TL M300
605TL M320
660TL M345
690TL M360
750TL M400
805TL M420
437 - 820 V
468 - 820 V
502 - 820 V
528 - 820 V
581 - 820 V
611 - 820 V
Input (DC)
Recommended PV array power range(1)
Voltage Range MPP(2)
1,050 V
Maximum voltage(3)
Maximum current
1,350 A
12 (extendable up to 16)
Fuse dimensions(4)
Type of connection
MPPT(5)
Max. current at each input
Input protections
Overvoltage protections
DC switch
Other protections
Output (AC)
Power @30 C / @45 C (6)
623.5 kVA /
573.7 kVA
665.1 kVA /
611.9 kVA
717.1 kVA /
659.7 kVA
300 V IT System
320 V IT System
345 V IT System
748.2 kVA /
688.4 kVA
873 kVA /
803.1 kVA
400 V IT System
420 V IT System
1,200 A / 1,104 A
Rated voltage
Frequency
360 V IT System
50 / 60 Hz
1
Power Factor(7)
Power Factor adjustable
THD (Total Harmonic Distortion)
831.4 kVA /
764.9 kVA
<3%
(8)
Output protections
Overvoltage protections
AC breaker
Optional AC circuit breaker with door control, remote trip or motorized (only DCAC models)
Anti-islanding protection
Other protections
Features
Maximum efficiency
98.9%
99%
99.1%
99.1%
99.1%
99.1%
Euroefficiency
98.5%
98.6%
98.7%
98.7%
98.7%
98.6%
Stand-by consumption(9)
90 W
Consumption at night
90 W
General Information
Operating temperature
-20 C to +55 C
Protection class
IP20 / IP54
3,000 m
Maximum altitude(10)
Cooling system
Air forced with temperature control (230 V phase + neutral power supply)
Air flow
Acoustic emission
Marking
CE
EN 61000-6-1, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, EN 62109-1, EN 62109-2, IEC62103, EN 50178, FCC Part 15, AS3100
IEC 62116, Arrt 23-04-2008, CEI 0-16 Ed. III, Terna A68, G59/2, BDEW-Mittelspannungsrichtlinie:2011, P.O.12.3, South African Grid code (ver 2.6),
Chilean Grid Code, Romanian Grid Code, Ecuadorian Grid Code, Peruvian Grid code, IEEE 929, Thailand MEA & PEA requirements, IEC61727,
UNE 206007-1, ABNT NBR 16149, ABNT NBR 16150, IEEE 1547, IEEE1547.1, GGC&CGC China, DEWA (Dubai) Grid Code, Jordan Grid Code
46
Notes: (1) Depending on the type of installation and geographical location. Data
for STC conditions (2) Vmpp.min is for rated conditions (Vac=1 p.u. and Power
Factor=1) (3) Consider the voltage increase of the Voc at low temperatures
(4)
For other configurations, consult with Ingeteam (5) The MPPT connected to the
same transformer throught TL inverters must have the same voltage configuration
(6)
For each C of increase between 30 C and 45 C, the output power will be reduced
at the rate of 0.53% / C. Over 45 C, the output power will be reduced at the rate of
1.8% / C (7) For Pout >25% of the rated power (8) For Pout >25% of the rated power and
voltage in accordance with IEC 61000-3-4 (9) Consumption from PV field (10) Over
1,000 m temperature for rated power is reduced at the rate of 4.5 C for each 1,000
m. For installations beyond the maximum altitude, please contact Ingeteams solar
sales department.
Vdc = 650 V
100
98
96
94
92
90
88
86
84
82
0
100
200
300
400
500
Power (kVA)
600
700
800
M Series
4 Power blocks
760TL M300
800TL M320
880TL M345
920TL M360
1000TL M400
1070TL M420
437 - 820 V
468 - 820 V
502 - 820 V
528 - 820 V
581 - 820 V
611 - 820 V
Input (DC)
Recommended PV array power range(1)
Voltage Range MPP(2)
1,050 V
Maximum voltage(3)
Maximum current
1,800 A
12 (extendable up to 16)
Fuse dimensions(4)
Type of connection
MPPT(5)
Max. current at each input
Input protections
Overvoltage protections
DC switch
Other protections
Output (AC)
Power @30 C / @45 C (6)
831.4 kVA /
764.9 kVA
886.8 kVA /
815.9 kVA
956.1 kVA /
879.6 kVA
300 V IT System
320 V IT System
345 V IT System
997.7 kVA /
917.8 kVA
1,163.9 kVA /
1,070.8 kVA
400 V IT System
420 V IT System
1,600 A / 1,472 A
Rated voltage
Frequency
360 V IT System
50 / 60 Hz
1
Power Factor(7)
Power Factor adjustable
THD (Total Harmonic Distortion)
1,108.5 kVA /
1,019.8 kVA
<3%
(8)
Output protections
Overvoltage protections
AC breaker
Optional AC circuit breaker with door control, remote trip or motorized (only DCAC models)
Anti-islanding protection
Other protections
Features
Maximum efficiency
98.9%
99%
99.1%
99.1%
99.1%
99.1%
Euroefficiency
98.5%
98.6%
98.7%
98.7%
98.7%
98.6%
Stand-by consumption(9)
120 W
Consumption at night
120 W
General Information
Operating temperature
-20 C to +55 C
Protection class
IP20 / IP54
3,000 m
Maximum altitude(10)
Cooling system
Air forced with temperature control (230 V phase + neutral power supply)
Air flow
Acoustic emission
Marking
CE
EN 61000-6-1, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, EN 62109-1, EN 62109-2, IEC62103, EN 50178, FCC Part 15, AS3100
IEC 62116, Arrt 23-04-2008, CEI 0-16 Ed. III, Terna A68, G59/2, BDEW-Mittelspannungsrichtlinie:2011, P.O.12.3, South African Grid code (ver 2.6),
Chilean Grid Code, Romanian Grid Code, Ecuadorian Grid Code, Peruvian Grid code, IEEE 929, Thailand MEA & PEA requirements, IEC61727,
UNE 206007-1, ABNT NBR 16149, ABNT NBR 16150, IEEE 1547, IEEE1547.1, GGC&CGC China, DEWA (Dubai) Grid Code, Jordan Grid Code
Notes: (1) Depending on the type of installation and geographical location. Data
for STC conditions (2) Vmpp.min is for rated conditions (Vac=1 p.u. and Power
Factor=1) (3) Consider the voltage increase of the Voc at low temperatures
(4)
For other configurations, consult with Ingeteam (5) The MPPT connected to the
same transformer throught TL inverters must have the same voltage configuration
(6)
For each C of increase between 30 C and 45 C, the output power will be reduced
at the rate of 0.53% / C. Over 45 C, the output power will be reduced at the rate of
1.8% / C (7) For Pout >25% of the rated power (8) For Pout >25% of the rated power and
voltage in accordance with IEC 61000-3-4 (9) Consumption from PV field (10) Over
1,000 m temperature for rated power is reduced at the rate of 4.5 C for each 1,000
m. For installations beyond the maximum altitude, please contact Ingeteams solar
sales department.
Vdc = 650 V
100
98
96
94
92
90
88
86
84
82
100
200
300
400
500
600
700
800
900
1000 1100
Power (kVA)
47
Solar inverters
PowerMax
SHE 22
50
Maximum stability
All the devices are anchored to the
base, to guarantee the maximum stability of the structure. The varnish used
guarantees maximum protection against
adverse weather conditions.
Complete accessibility
Thanks to its innovative design, all devices are readily accessible, thereby making it easier to inspect, maintain and repair the INGECON SUN PowerStation
SHE 22. The MV transformer compartment door is equipped with AREL safety lock with a blocking code.
Innovative ventilation system
The internal temperature of inverter compartment is controlled by high efficiency
hot air extraction plenums and centrifugal
fan systems. A number of internal and external probes guarantee a constant ambient temperature. The incoming air is
filtered through special grids mounted on
the bottom of the walls.
SHE 22 FA / NA / FA
SHE 22 FA / FA / FA
SHE 22 FA / NA / FA
SHE 22 FA / FA / FA
Main Features
Electrical Protections
Reverse polarity.
DC fuses.
Optional equipment
Fully customizable.
Standard Equipment
Meteo Station.
High-speed Ethernet / Fiber Optic
communication infrastructure for Plug & Play
connection to PV Plant Controller and
SCADA systems.
SCADA supervision, control and data
acquisition system.
PV Plant Controller compliant with the most
widely international Grid Codes.
Gateway for monitoring and control of the
PV Plant by the Grid Operator using standard
protocols (like IEC 61850, IEC 60870-5-101/104,
DNP 3.0, etc.).
HV surge arresters.
PowerStation SHE 22
Anti-rodent system.
External lighting system.
51
SHE 22
Air extraction
anti-rain covers
INGECON SUN
PowerMax inverters
up to 3280 kVA
Easily adaptable to
different ground surfaces
52
PowerStation SHE 22
SHE 22 - FA / FA / FA
SHE 22 - FA / NA / FA
General Information
Cooling system
400 W
Inverter Compartment
IP54
2,328 kVA @ 30 C
2,142 kVA @ 45 C
2,328 kVA @ 35 C
2,142 kVA @ 50 C
3,275 kVA @ 25 C
2,728 kVA @ 50 C
Forced air with temperature control
2,720 W
0W
IP54
IP21
Cooling system
Tranformer Compartment
Protection degree
Cooling system
MV Cubicle compartment(2)
Protection degree
130 W
IP55
Protection degree
Operating temperature range(3)
0 - 100%
Installation altitude(4)
Equipment
X series (Master-Slave), M series (Multi-MPPT), B series (Monoblock)
Inverter version
BT-AUX switchgear
LV / MV Transformer
MV Switchgear
0L1P, 1L1P or 2L1P cells with either fuses or circuit breaker protection
Mechanical Information
Structure Material
Steel
Insulation
Notes: (1) Equipped with oil immersed hermetically sealed LV / MV transformers (2) Including instrumentation, auxiliary services switchgear, monitoring systems (3) INGECON SUN
PowerMax, M and X series: rated output power indicated in the Technical Characteristics tables is guaranteed up to 45 C operating temperature. Derating above 45 C of 1.8% for
each C of increase until 60 C operating temperature. -30 C with optional kit (3) INGECON SUN PowerMax, B series: rated output power indicated in the Technical Characteristics
tables is guaranteed up to 50 C operating temperature. Derating above 50 C of 1.8% for each C of increase until 60 C operating temperature. -30 C with optional kit (4) Please contact
Ingeteam for altitudes higher than 1,000 m.
Length
Width
Height
Size (mm)
Body dimensions
6,750
2,450
3,050
8,760
3,950
3,050
8,560
6,750
3,050
Foundation dimensions
9,000
5,000
300
3,050
6,750
SHE 22 Wing
SHE 22 Tunnel
6,7
50
2, 4
50
8,560
3,950
6,7
2.896
3,050
8,760
50
2, 4
50
53
54
Main Features
Standard Equipment
MV switchgear.
Electrical Protections
Reverse polarity.
Output short-circuits and overloads.
DC fuses.
DC switch with door control.
AC circuit breaker with door control.
DC and AC overvoltage suppressors.
Anti-islanding monitoring system with
automatic disconnection.
Optional equipment
Meteo station.
HV surge arresters.
Anti-rodent system.
Human intrusion detection system.
External lighting system.
Oil retention tank (separately supplied).
Energy meter for auxiliary services
and/or energy production.
Insulation Monitoring Relay for continuous
monitoring of IT systems insulation.
Three-phase Capacitors with blocking
inductances for Power Factor correction.
DC and AC cable terminals.
Reactive power regulation with no
PV array power.
Ground connection of the PV array.
Painted with specific RAL upon request.
55
Easily adaptable to
different ground surfaces
Ease of maintenance
INGECON SUN
PowerMax B series Outdoor
inverters up to 2330 kVA
Oil immersed
hermetically sealed
MV Transformer
up to 36 kV
IP55
Forced Air
ventilation
MV Cubicle
and LV Auxiliary
compartment
56
General Information
Cooling system
6 kVA
Outdoor PV inverters (IP56)
Inverter Compartment
LV / MV Transformer compartment
(1)
2,328 kVA @ 35 C
2,142 kVA @ 50 C (with 2 inverters)
1,637 kVA @ 25 C
1,364 kVA @ 50 C (with 1 inverter)
Cooling system
0W
Protection degree
Cooling system
MV Cubicle compartment(2)
Protection degree
65 W
Protection degree
IP55 / NEMA 3R
Equipment
Inverter version
B series (Monoblock)
LV / MV Transformer
MV Switchgear
0L1P, 1L1P or 2L1P cells with either fuses or circuit breaker protection
Mechanical Information
Structure Material
Steel
Notes: (1) Including instrumentation, auxiliary services switchgear, monitoring systems (2) Equipped with oil immersed hermetically sealed LV / MV transformer (3) For INGECON
SUN PowerMax, B series: rated output power indicated in the Technical Characteristics tables is guaranteed up to 50 C operating temperature. Derating above 50 C
of 1.8% for each C of increase until 55 C operating temperature (4) -30 C with optional kit (5) Please contact Ingeteam for altitudes higher than 1,000 m.
Length
Width
Height
Size (mm)
Body dimensions
Overall dimensions with all doors open
Foundation dimensions
6,057
2,438
2,591
7,228.5
4,605.2
2,591
8,000
5,000
300
2,591
2,438
CON 20 NA / NA / FA
6,0
57
6,057
2,591
4,605.2
3
2,4
7,2
28
.5
.2
05
4,6
7,228.5
57
58
Complete accessibility
Thanks to its innovative design, all devices are readily accessible, thereby
making it easier to inspect, maintain
and repair the INGECON SUN PowerStation CON 40. The transformer compartment door is equipped with a safety
lock with a blocking code.
Grid support
These PV inverters have been designed
to comply with the most demanding international grid codes, contributing to
the quality and stability of the electric
system. Low voltage ride-through capability, reactive power deliverance and
active power control are just some of
their main features.
Main Features
Electrical Protections
Reverse polarity.
DC fuses.
Optional equipment
Meteo Station.
Standard Equipment
MV switchgear.
Auxiliary power outlet.
Fire safety kit.
Medium Voltage safety kit.
HV surge arresters.
External lighting system.
59
MV transformer compartment
with protective metal grids
Easily adaptable to
different ground surfaces
Ease of maintenance
Oil immersed
hermetically sealed
MV Transformer
up to 36 kV
IP55
forced air ventilation
Auxiliary compartment
IP55
Forced Air
ventilation
MV Cubicle
compartment
INGECON SUN
PowerMax B series
Outdoor inverters
up to 3500 kVA
IP21
high efficiency transformer compartment
with natural air ventilation
60
General Information
Cooling system
9 kVA
Outdoor PV inverters (IP56)
Inverter Compartment
LV / MV Transformer compartment
(1)
3,492 kVA @ 35 C
3,213 kVA @ 50 C (with 3 inverters)
3,275 kVA @ 25 C
2,728 kVA @ 50 C (with 2 inverters)
Cooling system
0W
Protection degree
IP21
Cooling system
MV Switchgear compartment(2)
Protection degree
65 W
Protection degree
IP55
Equipment
Inverter version
B series (Monoblock)
LV / MV Transformer
MV Switchgear
Mechanical Information
Structure Material
Steel
Insulation
Notes: (1) Equipped with oil immersed hermetically sealed LV / MV transformer (2) Including instrumentation, auxiliary services switchgear, monitoring systems (3) For INGECON SUN PowerMax, B series: rated output power indicated in the Technical Characteristics tables is guaranteed up to 50 C operating temperature. Derating above 50 C of 1.8% for each C of increase
until 55 C operating temperature (4) -30 C with optional kit (5) Please contact Ingeteam for altitudes higher than 1000 m.
Length
Width
Height
12,192
2,438
2,898
13,452
3,400
2,898
Foundation dimensions
13,500
4,450
300
Size (mm)
Body dimensions
2,898
CON40 NA / NA / FA
,19
2
2, 4
3,400
12
2,898
12,192
38
13,452
61
62
CON 40 FA / NA / FA
CON 40 FA / FA / FA
CON 40 AC-RC / NA / FA
CON 40 AC-RC / FA / FA
Main Features
Electrical Protections
Reverse polarity.
DC fuses.
Optional equipment
Meteo station.
Anti-rodent system.
63
MV transformer compartment
with protective metal grids
Easily adaptable to
different ground surfaces
INGECON SUN
PowerMax inverters
up to 3275 kVA
Ease of maintenance
Oil immersed
hermetically sealed
MV Transformer
up to 36 kV
IP55
Forced Air
ventilation
MV Cubicle
compartment
IP21
high efficiency
Natural Air ventilation
MV Transformer compartment
IP54
Inverter compartment
64
CON 40 AC / xx / FA
CON 40 RC / xx / FA
General Information
Inverter Compartment
420 W
18,000 W
IP54
IP54
IP65
Protection degree
(1)
2,328 kVA @ 30 C
2,142 kVA @ 45 C
2,328 kVA @ 35 C
2,142 kVA @ 50 C
Cooling system
LV / MV Transformer compartment
CON 40 FA or AC or RC/FA/FA
2,720 W
Protection degree
IP54
Cooling system
LV / MV Transformer compartment(3)
CON 40 FA or AC or RC/NA/FA
0W
Protection degree
IP21
Cooling system
MV Cubicle compartment
Cooling system
65 W
Protection degree
IP55
0-100%
Equipment
Inverter version
BT-AUX switchgear
LV / MV Transformer
MV Switchgear
0L1P, 1L1P or 2L1P cells with either fuses or circuit breaker protection
Mechanical Information
Structure Material
Steel
Insulation
Notes: (1) Including inverters, instrumentation, auxiliary services switchgear, monitoring systems (2) Pure Free Cooling function / Cooling function (3) Equipped with oil immersed hermetically
sealed LV / MV transformers (4) For INGECON SUN PowerMax, M and X series: rated output power indicated in the Technical Characteristics tables is guaranteed up to 45 C
operating temperature. Derating above 45 C of 1.8% for each C of increase until 60 C operating temperature (4) For INGECON SUN PowerMax, B series: rated output power indicated
in the Technical Characteristics tables is guaranteed up to 50 C operating temperature. Derating above 50 C of 1.8% for each C of increase until 60 C operating temperature (5) -30 C
with optional kit (6) Please contact Ingeteam for altitudes higher than 1,000 m (7) Not available with air conditioning.
Length
Width
Height
Body dimensions
12,192
2,438
2,896
14,400
3,700
2,896
Foundation dimensions
14,142
5,000
300
Size (mm)
5,000
CON 40
,19
2
5,000
12
2,896
14,400
2, 4
38
14,400
65
Ease of maintenance
INGECON SUN
PowerMax inverters
up to 4920 kVA
Outdoor mounted
oil immersed hermetically sealed
LV / MV Transformer up to 36 kV
IP55
Forced Air ventilation
MV Cubicle compartment
IP54
Inverter compartment
66
CON 40 AC / OD / FA
CON 40 RC / OD / FA
630 W
24,000 W
IP54
IP54
IP65
Cooling system
Inverter Compartment
Protection degree
(1)
3,492 kVA @ 30 C
3,213 kVA @ 45 C
3,492 kVA @ 35 C
3,213 kVA @ 50 C
Cooling system
MV Cubicle compartment
65 W
Protection degree
IP55
Outdoor mounting with protective perimeter metal fence
Mounting type
LV / MV Transformer
General Information
Cooling system
0-100%
Equipment
X series (Master-Slave), M series (Multi-MPPT), B series (Monoblock)(6)
Inverter version
BT-AUX switchgear
LV / MV Transformer
MV Switchgear
Mechanical Information
Structure Material
Steel
Insulation
Notes: (1) Including inverters, instrumentation, auxiliary services switchgear, monitoring systems (2) Pure Free Cooling function / Cooling function (3) For INGECON SUN PowerMax, M or
X series: rated output power indicated in the Technical Characteristics tables is guaranteed up to 45 C operating temperature. Derating above 45 C of 1.8% for each C of increase until
55 C operating temperature (3) For INGECON SUN PowerMax, B series: rated output power indicated in the Technical Characteristics tables is guaranteed up to 50 C operating
temperature. Derating above 50 C of 1.8% for each C of increase until 55 C operating temperature (4) -30 C with optional kit (5) Please contact Ingeteam for altitudes higher than 1,000
m (6) Not available with air conditioning.
Length
Width
Height
CON 40 dimensions
12,192
2,438
2,896
14,400
3,700
2,896
2,600
1,400
2,700
Foundation dimensions
14,142
7,500
300
Size (mm)
CON 40
12
2,896
2,600
1,400
,19
2
2, 4
38
14,400
67
FULL SKID
UL 1741
COMPLIANT
68
Complete accessibility
Thanks to the lack of housing, the inverters can have immediate access.
Furthermore, the design of the B Series
central inverters has been conceived to
facilitate maintenance and repair works.
Maximum protection
Ingeteams B Series central inverters integrate the latest generation electronics
and a much more efficient electronic
protecion. Apart from that, they feature the main electrical protections and
they deploy grid support functionalities,
such as low voltage ride-through capability, reactive power deliverance and
active power injection control.
PowerStation U
69
Single Inverter
Power Station
From 610 kVA up to 1,164 kVA at 1,000 Vdc.
From 1,170 kVA up to 1,637 kVA at 1,500 Vdc.
Double Inverter
Power Station
From 1,220 kVA up to 2,328 kVA at 1,000 Vdc.
From 2,340 kVA up to 3,275 kVA at 1,500 Vdc.
Triple Inverter
Power Station
From 1,830 kVA up to 3,492 kVA at 1,000 Vdc.
From 3,510 kVA up to 4,911 kVA at 1,500 Vdc.
PV inverter #1
LINE IN
Pad-mounted
Transformer
PV inverter #2
HV Protection
2
LINE OUT
PV inverter #3
Auxiliary
Services
Optional
70
4-position
T-blade switch
PowerStation U
STANDARD EQUIPMENT
Liquid-filled pad-mounted
transformer up to 35 kV class
(ask Ingeteam for transformer
details).
Metering equipment.
Remote communications.
DOE 2016 transformer.
SCADA for system supervision.
Integration of DC recombiners
(ask Ingeteam for modifications
on the power station design).
1,070 kVA
2,140 kVA
3,210 kVA
Max. power @ 25 C / 77 F
1,164 kVA
2,328 kVA
Number of inverters
Skid Size
1,00
0 Vdc
3,492 kVA
20 x 7 ft
20 x 8 ft
Transformer arrangemet
99.2%
99.31%
99.23%
15 / 25 / 35 kV
15 / 25 / 35 kV
15 / 25 / 35 kV
30 x 8 ft
Up to 3,000 m
Up to 3,000 m
Up to 3,000 m
NEMA 3
NEMA 3
NEMA 3
8 ft
8 ft
20 ft
8 ft
20 ft
30 ft
1,364 kVA
2,728 kVA
4,092 kVA
Max. power @ 25 C / 77 F
1,637 kVA
3,275 kVA
20 x 8 ft
20 x 11 ft
Transformer arrangemet
99.2%
99.31%
99.23%
15 / 25 / 35 kV
15 / 25 / 35 kV
15 / 25 / 35 kV
Skid Size
1,50
0 Vdc
4,911 kVA
30 x 11 ft
Up to 6,562 ft (2,000 m)
Up to 6,562 ft (2,000 m)
Up to 6,562 ft (2,000 m)
NEMA 3
NEMA 3
NEMA 3
8 ft
11 ft
20 ft
20 ft
11 ft
30 ft
71
CONSTRUCTION
72
CON 20 OD / OD / FA
(up to 3280 kVA)
CON 20 OD / OD / FA
(up to 4920 kVA)
CON 20 OD / OD / FA
(up to 6,560 kVA)
Main Features
Standard Equipment
MV switchgear.
Auxiliary power outlet.
(1)
Electrical Protections
Reverse polarity.
Output short-circuits and overloads.
DC fuses.
Motorized DC switches with door control.
AC thermal-magnetic breakers with door control.
DC and AC overvoltage suppressors.
Anti-islanding monitoring system with automatic
disconnection.
Insulation monitoring system.
Automatic disconnection system in case of
LV / MV transformer overheat.
Emergency disconnection button, accessible
from outside.
DGPT2 protection relay included in the transformer.
Anti-rodent system.
HV surge arresters.
Human intrusion detection system.
External lighting system.
Oil retention tank (separately supplied).
Energy meter for auxiliary services and / or
energy production.
Insulation monitoring relay for continuous
monitoring of IT systems insulation.
Three-phase capacitors with blocking
inductances for Power Factor correction.
Reactive power regulation with no PV
array power.
Ground connection of the PV array.
Painted with specific RAL upon request.
(1)
73
INGECON SUN
PowerMax B series
Outdoor inverters
Ease of maintenance
Suitable for installation
on concrete slab
MV transformer compartment
with protective metal grids
Oil immersed
hermetically sealed
MV Transformer
up to 36 kV
INGECON SUN
PowerMax inverters
up to 6560 kVA
Suitable for installation
on concrete piers
IP55
Forced Air
ventilation
MV Cubicle and
LV Auxiliary
compartment
74
Number of inverters
2,328 kVA @ 35 C
2,142 kVA @ 50 C
3,492 kVA @ 35 C
3,213 kVA @ 50 C
4,660 kVA @ 35 C
4,284 kVA @ 50 C
3,274 kVA @ 25 C
2,728 kVA @ 50 C
4,910 kVA @ 25 C
4,092 kVA @ 50 C
6,548 kVA @ 25 C
5,456 kVA @ 50 C
Cooling system
Central Inverters
5 kVA
7.5 kVA
Protection rating
0W
Protection rating
Hermetically sealed
Cooling system
LV and MV
Switchgear
compartment (1)
260 W
Protection rating
IP55
-20 to +55 C (3)
0 - 100%
Relative humidity
Installation altitude
10 kVA
IP56
Cooling system
LV / MV
Transformer
General Information
(6)
Equipment
Inverter version
LV Auxiliary Switchgear
LV / MV Transformer
MV Switchgear
0L1P, 1L1P or 2L1P cells with either fused or circuit breaker protection
Mechanical Information
Structure Material
Steel
Insulation
Notes: (1) Including instrumentation, auxiliary services switchgear, monitoring systems (2) For INGECON SUN PowerMax B series 1,000 V and 1,500 V series: rated output power indicated
in the Technical Characteristics tables is guaranteed up to 50 C operating temperature. Derating above 50 C of 1.8% for each C of increase until 55 C operating temperature (3) -30 C
with optional kit (4) Please contact Ingeteam for altitudes higher than 1,000 m.
2 inverters
3 inverters
4 inverters
Length
1,290
1,650
1,650
1,400
1,760
1,760
Width
3.25
3.25
3.25
4.66
4.66
4.66
Size (cm)
3.25
3.25
1,290
2 inverters
3.25
CON20 OD / OD / FA
1,650
3 inverters
1,650
4 inverters
75
Configuration
This system is very flexible and offers
different configuration possibilities. A
single component can control all the
elements, reducing production times,
facilitating the maintenance and making repairing processes more efficient.
National grid
administrator
+ MV
MV
MV
MV
National grid
administrator
+ MV
National grid
administrator
+ MV
MV
MV
MV
MV
MV
76
Electric diagrams
String Box 1
String Box 2
MV / LV Transformer
M
String Box n
n (2..4)
n (max 16)
MV switchgear
String Box 1
String Box 2
LV / LV Transformer
M
String Box n
n (2..4)
n (max 16)
BT-AUX
Auxiliary services
String Box 1
String Box 4
String Box n-3
String Box n
n (2..4)
MV / LV Transformer
n (8..16)
MV switchgear
String Box 1
LV / LV Transformer
String Box 4
String Box n-3
String Box n
n (2..4)
BT-AUX
n (8..16)
Auxiliary services
String Box n
MV / LV Transformer
1
n (max 15)
MV switchgear
INGECON SUN PowerMax B Series
3
String Box 1
LV / LV Transformer
String Box 2
String Box n
BT-AUX
Auxiliary services
n (max 15)
77
80
Consumption
The AC-Link
Concept
PV array
Batteries
Genset
ADVANTAGES
100.0
80.0
60.0
40.0
20.0
22:00
20:00
18:00
16:00
14:00
12:00
10:00
8:00
4:00
6:00
2:00
0.00
0:00
Power (kW)
120.0
Battery charging
81
With transformer
3/6
Single-phase battery inverter with transformer
The INGECON SUN STORAGE 1Play
battery inverter is a single-phase, twoway unit that can either be used in offgrid systems or connected to the general supply network.
PV input
INGECON SUN STORAGE 1Play inverters incorporate a PV input. Thanks
to this input, the PV array can be connected directly to the inverter.
Battery management
The INGECON SUN STORAGE 1Play
inverters feature cutting-edge technology to control the charging and discharging of the storage system in order to maximise the battery service
life. The battery temperature could be
controlled at all times, ensuring correct
battery operation and durability. The
inverter incorporates a pre-charge system to avoid battery inrush currents.
Back-up genset
The INGECON SUN STORAGE 1Play
permits the connection of a backup genset, should this be necessary.
Furthermore, the inverter can be started-up using this generator, in order to
charge the batteries when these are
completely discharged.
PROTECTIONS
PV input.
CAN communication for smart batteries.
Configurable potential-free inputs.
Configurable potential-free outputs,
some for the connection and
disconnection of the back-up genset.
DC pre-charge system.
Battery temperature measurement
circuit built-in. PT100 (3-wire) needed.
82
Back-up mode
This operating mode has been designed for grid-connected systems,
where grid outages are long and frequent, meaning that a back-up power
source is required. The INGECON
SUN STORAGE 1Play inverter operates through a connection to the AC
grid. In order to guarantee a power
source, the inverter maintains the batteries charged. During a grid outage,
the battery inverter generates the AC
network and the energy stored in the
batteries is used to power the loads.
If any renewable energy sources are
connected to the grid and the energy
generated is greater than the one demanded, then the surplus could be injected into the grid.
Self-consumption mode
This operating mode is conceived for
grid-connected systems with renewable energy sources, in order to minimise grid consumption. If the ener-
Connection Schema
Single-phase
Three-phase
DC
DC
PV array
PV array
Consumption
Batteries
INGECON SUN
STORAGE 1Play
AC
DC
AC
DC
Consumption
Batteries*
INGECON SUN
STORAGE 1Play
AC
AC
Genset or grid
Genset or grid
DC
DC
PV array
AC
AC
INGECON SUN
1Play
PV array
INGECON SUN
1Play
83
Operating modes:
Stand-alone mode
The INGECON SUN STORAGE 1Play
inverter generates a stand-alone AC grid
and acts as a grid manager, guaranteeing the correct balance between generation, consumption and the storage
system. To do so, it controls the energy
flow between the grid and the batteries,
based on the status at any given time.
Transformerless
3TL / 6TL
Single-phase transformerless battery inverter
The INGECON SUN STORAGE 1Play
TL battery inverter is a single-phase,
two-way unit that can either be used
in off-grid systems or connected to the
general supply network.
PV input
INGECON SUN STORAGE 1Play TL inverters incorporate a PV input. Thanks
to this input, the PV array can be connected directly to the inverter.
Battery management
The INGECON SUN STORAGE 1Play
TL inverters feature cutting-edge technology to control the charging and
discharging of the storage system in
order to maximise the battery service
life. The battery temperature could be
controlled at all times, ensuring correct
battery operation and durability. The
inverter incorporates a pre-charge system to avoid battery inrush currents.
Back-up genset
The INGECON SUN STORAGE 1Play
TL permits the connection of a backup genset, should this be necessary.
Furthermore, the inverter can be started-up using this generator, in order to
charge the batteries when these are
completely discharged.
PROTECTIONS
AC overvoltages.
Insulation faults.
Output shortcircuits and overloads.
Optional accesSories
PV input.
CAN communication for smart batteries.
Configurable potential-free inputs.
Configurable potential-free outputs,
some for the connection and
disconnection of the back-up genset.
DC pre-charge system.
Battery temperature measurement
circuit built-in. PT100 (3-wire) needed.
84
Back-up mode
This operating mode has been designed for grid-connected systems,
where grid outages are long and frequent, meaning that a back-up power
source is required. The INGECON
SUN STORAGE 1Play TL inverter operates through a connection to the AC
grid. In order to guarantee a power
source, the inverter maintains the batteries charged. During a grid outage,
the battery inverter generates the AC
network and the energy stored in the
batteries is used to power the loads.
If any renewable energy sources are
connected to the grid and the energy
generated is greater than the one demanded, then the surplus could be injected into the grid.
Self-consumption mode
This operating mode is conceived for
grid-connected systems with renewable energy sources, in order to minimise grid consumption. If the ener-
Connection Schema
DC
PV array
AC
DC
Consumption
Batteries
INGECON SUN
STORAGE 1Play
AC
Genset or grid
DC
PV array
AC
INGECON SUN
1Play
85
Operating modes:
Stand-alone mode
The INGECON SUN STORAGE 1Play
TL inverter generates a stand-alone
AC grid and acts as a grid manager,
guaranteeing the correct balance between generation, consumption and
the storage system. To do so, it controls the energy flow between the grid
and the batteries, based on the status
at any given time.
PV Input (DC)
PV array max. power
7.5 kWp
11.5 kWp
300 - 480 V
300 - 480 V
330 - 480 V
330 - 480 V
550 V
550 V
Maximum current
20 A
30 A
Inputs
MPPT
40 - 300 V
40 - 300 V
40 - 450 V
40 - 450 V
50 A
50 A
Battery type
230 V
230 V
Voltage range
172 - 264 V
172 - 264 V
Rated frequency
50 / 60 Hz
50 / 60 Hz
Frequency range
40 - 70 Hz
40 - 70 Hz
0 - 13 A
0 - 26 A
11,500 W
11,500 W
Output (AC)
Rated power(3)
Power (25 C) 30 min, 2 min, 3 s(4)
3 kW
6 kW
13 A
26 A
Rated voltage(5)
Current
200 - 240 V
200 - 240 V
Rated frequency(5)
50 / 60 Hz
50 / 60 Hz
95.5%
96%
Efficiency
Maximum efficiency
General Information
Stand-by consumption
<10 W
<10 W
Ambient temperature
-20 C to +65 C
-20 C to +65 C
0-100%
0-100%
IP65
IP65
Compliance with standards: EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-12, EN 61000-3-11, EN 62109-1, EN 62109-2, IEC62103, EN 50178, FCC Part
15, AS 3100*, RD1699/2011, DIN V VDE V 0126-1-1, EN 50438, CEI 0-21*, VDE-AR-N 4105:2011-08, G59/2, G83/2(6), AS4777.2*, AS4777.3*, IEC 62116, IEC 61727, UNE 206007-1,
NRS 097-2-1.
Notes: (1) Grid-connected modes include Back-up, Self-consumption and Grid Support. Minimum voltage DC (VDC, min) for Vgrid,max = 1.1 p.u. If Vgrid,max is higher than this value, the
minimum voltage should be corrected as VDC, min * Vgrid,max / 1.1 (2) The inverters maximum power will be the battery voltage multiplied by the maximum discharge current (50 A)
(3)
AC power up to 40 C ambient temperature (4) This power is only available if the battery voltage multiplied by the maximum discharge current reaches these values (5) This parameter is
configurable through the display (6) Related only to inverters up to 16 A.
DC
PV array
AC
DC
Batteries
Consumption
INGECON SUN
STORAGE 1Play
AC
Genset or grid
470
3
43.3 kg.
6
65 kg.
3000
36
86
Transformer
0
0
14
0
18 0
32
No PV
0
20
40
60
80
100
120
...
300
...
450 VBat
6TL
PV Input (DC)
PV array max. power
7.5 kWp
11.5 kWp
300 - 480 V
300 - 480 V
330 - 480 V
330 - 480 V
550 V
550 V
Maximum current
20 A
30 A
Inputs
MPPT
40 - 300 V
40 - 300 V
40 - 450 V
40 - 450 V
50 A
50 A
Battery type
Rated voltage
230 V
230 V
Voltage range
172 - 264 V
172 - 264 V
Rated frequency
50 / 60 Hz
50 / 60 Hz
Frequency range
40 - 70 Hz
40 - 70 Hz
0 - 13 A
0 - 26 A
11,500 W
11,500 W
Output (AC)
Rated power(3)
Power (25 C) 30 min, 2 min, 3 s(4)
3 kW
6 kW
13 A
26 A
Rated voltage(5)
Current
200 - 240 V
200 - 240 V
Rated frequency(5)
50 / 60 Hz
50 / 60 Hz
95.5%
96%
Efficiency
Maximum efficiency
General Information
Stand-by consumption
<10 W
<10 W
Ambient temperature
-20 C to +65 C
-20 C to +65 C
0-100%
0-100%
IP65
IP65
Compliance with standards: EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-12, EN 61000-3-11, EN 62109-1, EN 62109-2, IEC62103, EN 50178, FCC Part
15, AS 3100*, RD1699/2011, DIN V VDE V 0126-1-1, EN 50438, CEI 0-21*, VDE-AR-N 4105:2011-08, G59/2, G83/2(6), AS4777.2*, AS4777.3*, IEC 62116, IEC 61727, UNE 206007-1,
NRS 097-2-1.
Notes: (1) Grid-connected modes include Back-up, Self-consumption and Grid Support. Minimum voltage DC (VDC, min) for Vgrid,max = 1.1 p.u. If Vgrid,max is higher than this value, the
minimum voltage should be corrected as VDC, min * Vgrid,max / 1.1 (2) The inverters maximum power will be the battery voltage multiplied by the maximum discharge current (50 A)
(3)
AC power up to 40 C ambient temperature (4) This power is only available if the battery voltage multiplied by the maximum discharge current reaches these values (5) This parameter is
configurable through the display (6) Related only to inverters up to 16 A.
DC
AC
DC
Batteries
Consumption
INGECON SUN
STORAGE 1Play
AC
Genset or grid
3TL
18.3 kg.
6TL
23.3 kg.
3000
No PV
36
0
18
20
40
60
80
100
120
...
300
...
450 VBat
87
88
proving the quality of supply and ensuring the high integration of solar energy
into the electricity system.
An energy storage system makes it possible to control the plant power output
ramps, based on pre-established values. Whenever a cloud passes over,
with the subsequent loss of irradiance,
the storage system provides the energy
required to offset the energy shortfall,
whilst the power output is progressively
reduced until it is equal to the PV power.
Once the cloud has gone, the available power increases sharply and this
is used to charge the batteries whilst
smoothly increasing the power output.
P out
Available PV power
18:30
17:30
16:30
15:30
14:30
13:30
12:30
11:30
8:30
9:30
10:30
STORAGE PowerMax
100%
1 min
1 min
8 min
Output power at an actual 1 MW PV plant on a day with scattered clouds, with and
without energy storage systems, implementing output power regulation.
20%
24 min
%
120
100
80
SOC
60
Battery State
of Charge
40
20
P pv
P ems
19:10
19:36
20:02
20:28
20:54
21:20
18:44
17:52
18:18
17:26
17:00
16:34
16:08
15:42
15:16
14:50
14:24
13:58
13:32
13:06
12:14
12:40
11:22
11:48
10:56
10:30
9:38
10:04
9:12
0
8:46
Output power on a day with scattered clouds, with and without energy storage
systems, implementing constant power control.
to either vary the diesel load balance system or to start up new generators.
DC and AC supplies together
The input and output supplies are integrated into the same cabinet, facilitating
maintenance and repair works.
Solutions available
Indoor inverters with an integrated
DCAC cabinet.
Indoor inverters with a DC cabinet.
Outdoor inverters with an integrated
DCAC cabinet.
89
With transformer
125 / 250
Three-phase battery inverter with transformer
Battery management
The INGECON SUN STORAGE Power
features high-tech battery management
in order to maximise the useful life
of the storage system. The battery temperature can be monitored at all times,
guaranteeing a correct operation.
90
Back-up genset
Furthermore, the INGECON SUN
STORAGE Power permits the connection of a back-up generator, should this
be necessary. It is possible to start-up
the inverter by using the genset, in order to charge the batteries.
Maximum compatibility
This inverter is 100% compatible with
the INGECON SUN inverters, making
it possible to integrate a solar energy
source into the AC grid. To do so, additional PV inverters are required.
Software included
The INGECON SUN Manager software
is included at no extra charge. This
can be used to monitor and record the
inverter data over the Internet. Ethernet communications are supplied
as standard.
Size (mm)
1,940
1,3
0
80
STORAGE Power
91
With transformer
Operating modes:
Stand-alone mode
The INGECON SUN STORAGE Power
generates a stand-alone AC grid and
acts as a grid manager, guaranteeing
the correct balance between generation, consumption and the storage
system. To achieve this, the INGECON
SUN STORAGE Power is able to control the energy flows between the grid
and the batteries, based on the status at any given time. The INGECON
SUN STORAGE Power inverter allows
a solar energy source to be integrated
into the grid, through the use of INGECON SUN inverters.
PROTECTIONS
Ethernet-TCP communication.
AC pre-charge system.
Optional Accessories
DC pre-charge system.
DC fuses.
Batteries
DC
AC
Consumption
AC
INGECON SUN
STORAGE Power
Optional
Genset or grid
DC
PV array
92
AC
STORAGE Power
125
250
Batteries (DC)
Voltage range for stand-alone mode
330 - 820 V
578 - 820 V
330 - 820 V
637 - 820 V
1,000 V
1,000 V
Maximum voltage(2)
Maximum current
400 A
450 A
Inputs
Type of battery
400 V
Voltage range
320 - 480 V
Frecuency
50 / 60 Hz
Frecuency Range
40 - 70 Hz
0 - 200 A
0 - 368 A
Maximum power
250 kVA
Rated power(3)
125 kVA
Maximum current
Output (AC)
250 kVA
200 A
368 A
Rated voltage
400 V
Frequency
50 / 60 Hz
Efficiency
Maximum efficiency
96.9%
97.5%
General Information
Galvanic isolation
Yes
Air cooling
2,600 m3/h
Stand-by consumption
30 W
Ambient temperature
-20 C to +65 C
0 - 95%
Maximum altitude(4)
3,000 m
Protection Class
IP20
Weight
1,162 kg
1,500 kg
Compliance with standards: EN 61000-6-1, EN 61000-6-2, EN 61000-6-4, EN 61000-3-12, EN 61000-3-11, EN 62109-1, EN 62109-2, IEC 62103, EN 50178, FCC Part 15, EN 50438,
IEC 62116, IEC 61727, VDE 0126-1-1
Notes: (1) Minimum voltage DC (Vdc,min) for Vgrid,max=1.1 p.u. and Power Factor=1. If Vgrid,max is higher than this value, the minimum voltage should be corrected as Vdc,min * Vgrid,max
/ 1.1 (2) Above 820 V, the maximum current decreases gradually (3) AC Power for 40 C ambient temperature (4) Over 1,000 m temperature for rated power is reduced at the rate of 4.5 C
for each 1,000 m.
Transformer
L1
AC Pre-charge
Battery
input
Filter
DC Pre-charge
Inverter
L2
L3
N
Optional
AC
output
for the
loads
L1
W
L2
L3
AC
input
for genset
or grid
93
B Series
Battery management
The INGECON SUN STORAGE Power
Max features a highly advanced battery control technology, ensuring the
maximum life of the storage system.
The battery temperature could be
controlled at all times ensuring an enhanced lifespan of the accumulator.
This inverter is 100% compatible with
Ingeteams PV inverters.
The INGECON SUN STORAGE PowerMax three-phase inverter complies with the
most demanding international standards.
Standard 3 year warranty, extendable
for up to 25 years
2, 8
Ethernet communication.
DC and AC surge arresters, type 2.
DC pre-charge system.
Optional Accessories
DC fuses.
DC and AC surge arresters, type 1.
AC pre-charge system.
PROTECTIONS
Insulation failures.
Outdoor inverter 1,000 Vdc
1,560 kg.
20
89
94
20
88
2, 8
Integrated Accessories
Size (mm)
2,010
Easy maintenance
String inverter philosophy has been applied in the design of this central inverter, facilitating the inverter usage. Moreover, the input and output lines are
integrated into the same cabinet, in order to make maintenance work easier.
Software included
Included at no extra cost the software
INGECON SUN Manager for monitoring and recording the inverter data
over the Internet. Ethernet communications are supplied as standard.
2,260
The INGECON SUN STORAGE PowerMax is a three-phase bidirectional battery inverter for grid-connected systems. This inverter offers a high-power
density in a single power block, providing different configurable operating
modes. Besides, it features the same
technology as Ingeteams PV inverters,
facilitating the supply of spare parts.
Frequency Regulation
In the event of an underfrequency,
an additional power injection is needed. The battery inverter will provide
this extra power for a certain period
of time.
Active Power Reserve
Some of the energy stored can be
saved in order to feed it to the grid
during short periods of time when it
is needed.
Digital Q Compensation
The battery inverter can control the
reactive power output and it can inject reactive power into the grid also
during the night.
grid operator
SCADA
DC
AC
Public Grid
INGECON SUN
PV array
Modbus TCP.
Modbus TCP; OPC
DC
AC
Battery Bank
STORAGE PowerMax
+15
...
Inverter
...
L1
AC Pre-charge
-1
-2
-3
Filter
DC Pre-charge
Battery
input
+3
+2
+1
Optional
L2
L3
AC
output for
connection
to a MV
network
Optional
-15
Optional
Optional
95
Operating modes:
The INGECON SUN STORAGE PowerMax B Series inverters usually work in
combination with Ingeteams INGECON
SUN PV inverters and INGECON SUN
EMS Plant Controller. With such a schema both inverter types (PV and batteries) could inject active and reactive
power into the grid at the same time, resulting in a much more efficient system.
STORAGE PowerMax
B Series
830TL B300
1000TL B360
480 - 820 V
574 - 820 V
1070TL B385
1110TL B400
614 - 820 V
637 - 820 V
Input (DC)
Battery voltage range(1)
Maximum voltage(2)
1,050 V
Maximum current
2,000 A
Type of battery
5 up to 15
Fuse dimensions
Type of connection
1,00
0 Vdc
Single copper bar (up to 30 cables) or mulitple copper bars with fuse holders
Input protections
Overvoltage protections
DC switch
Other protections
Up to 15 pairs of DC fuses (optional) / Insulation failure monitoring / Anti-islanding protection / Emergency pushbutton
Output (AC)
Power @ 35 C / @ 50 C(3)
Current @ 35 C / @ 50 C
Rated voltage
300 V IT System
360 V IT System
Frequency
385 V IT System
400 V IT System
50 / 60 Hz
Power Factor(4)
1,600 A / 1,472 A
(5)
Type of connection
Output protections
Overvoltage protections
AC breaker
Anti-islanding protection
Other protections
Features
Maximum efficiency
98.7%
98.9%
98.9%
98.9%
Euroefficiency
98.3%
98.5%
98.5%
98.6%
2,500 VA
18 kWh
60 W
General Information
Ambient temperature
Relative humidity (non-condensing)
Protection class
-20 C to +55 C
0 - 100%
IP50 (Indoor) / IP56 (Outdoor)
Max. altitude(7)
3,000 m
Cooling system
Forced air with temperature control (230 V phase + neutral power supply)
Air volume
Noise emission
Marking
6,200 m3/h
<77 dB(A) at 1 m
CE, ETL
IEC 62116, Arrt 23-04-2008, CEI 0-16 Ed. III, Terna A68, G59/2, BDEW-Mittelspannungsrichtlinie:2011, P.O.12.3,
South African Grid code (ver 2.6), Chilean Grid Code, Ecuadorian Grid Code, Peruvian Grid code, Thailand PEA requirements,
IEC61727, UNE 206007-1, ABNT NBR 16149, ABNT NBR 16150, IEEE 1547, IEEE1547.1, GGC&CGC China,
DEWA (Dubai) Grid code, Jordan Grid Code
Notes: (1) Minimum voltage DC (VDC, min) for Vgrid,max = 1.1 p.u. and Power Factor=1. If Vgrid,max is higher than this value, the minimum voltage should be corrected as VDC, min * Vgrid,max /
1.1 (2) Beyond 820 V, the maximum current decreases gradually (3) For each C of increase between 35 C and 50 C, the output power will be reduced at the rate of 0.53% / C. Over 50 C,
the output power will be reduced at the rate of 1.8% / C (4) For P out >25% of the rated power (5) For P out >25% of the rated power and voltage in accordance with IEC 61000-3-4
(6)
Consumption from battery (7) Over 1,000 m, temperature for rated power is reduced at the rate of 4.5 C for each 1,000 m. For installations beyond the maximum altitude, please contact
Ingeteams solar sales department.
96
STORAGE PowerMax
B Series
1170TL B450
1400TL B540
1500TL B578
1560TL B600
1600TL B615
1640TL B630
715 - 1,300 V
856 - 1,300 V
916 - 1,300 V
950 - 1,300 V
974 - 1,300 V
998 - 1,300 V
Input (DC)
Battery voltage range(1)
Maximum voltage(2)
1,500 V
Maximum current
2,000 A
Type of battery
1,50
0 Vdc
6 up to 15 (optional)
Fuse dimensions
Type of connection
Single copper bar (up to 30 cables) or multiple copper bars with fuse holders
Input protections
Overvoltage protections
DC switch
Other protections
Power @ 25 C / @ 50 C(3)
Current @ 25 C / @ 50 C
Rated voltage
450 V IT System
540 V IT System
Frequency
578 V IT System
600 V IT System
615 V IT System
630 V IT System
50 / 60 Hz
Power Factor(4)
Power Factor adjustable
1,500 A / 1,250 A
1
Yes. Smax=1,169 kVA
<3%
Connection to copper bars
Output protections
Overvoltage protections
AC breaker
Anti-islanding protection
Other protections
Features
Maximum efficiency
Euroefficiency
Max. consumption aux. services
Average energy consumption per day
Stand-by or night consumption(6)
98.9%
98.5%
2,500 VA
18 kWh
60 W
General Information
Ambient temperature
Relative humidity (non-condensing)
Protection class
-20 C to +55 C
0 - 100%
IP50 (Indoor) / IP56 (Outdoor)
Max. altitude(7)
2,000 m
Cooling system
Forced air with temperature control (230 V phase + neutral power supply)
Air volume
Noise emission
Marking
6,200 m3/h
<77 dB(A) at 1 m
CE, ETL
IEC 62116, Arrt 23-04-2008, CEI 0-16 Ed. III, Terna A68, G59/2, BDEW-Mittelspannungsrichtlinie:2011, P.O.12.3,
South African Grid code (ver 2.6), Chilean Grid Code, Ecuadorian Grid Code, Peruvian Grid code, Thailand PEA requirements,
IEC61727, UNE 206007-1, ABNT NBR 16149, ABNT NBR 16150, IEEE 1547, IEEE1547.1, GGC&CGC China,
DEWA (Dubai) Grid code, Jordan Grid Code
Notes: (1) Minimum voltage DC (VDC, min) for Vgrid,max = 1.1 p.u. and Power Factor=1. If Vgrid,max is higher than this value, the minimum voltage should be corrected as VDC, min * Vgrid,max /
1.1 (2) Beyond 820 V, the maximum current decreases gradually (3) For each C of increase between 25 C and 50 C, the output power will be reduced at the rate of 0.66% / C. Over 50 C,
the output power will be reduced at the rate of 1.8% / C (4) For P out >25% of the rated power (5) For P out >25% of the rated power and voltage in accordance with IEC 61000-3-4
(6)
Consumption from battery (7) Over 1,000 m, temperature for rated power is reduced at the rate of 4.5 C for each 1,000 m. For installations beyond the maximum altitude, please contact
Ingeteams solar sales department.
97
Output (AC)
U B Series
UL 9540
& UL 1741
COMPLIANT
Software included
Included at no extra cost the software
INGECON SUN Manager for monitoring and recording the inverter data
over the Internet. Ethernet communications are supplied as standard.The
INGECON SUN STORAGE PowerMax
three-phase inverter complies with the
most demanding international standards.
Easy maintenance
String inverter philosophy has been applied in the design of this central inverter, facilitating the inverter usage. Moreover, the input and output lines are
integrated into the same cabinet, in order to make maintenance work easier.
80
Optional Accessories
DC fuses.
AC pre-charge system.
Heating kit, for operating at an ambient
temperature of -30 C (-22 F).
PROTECTIONS
11
1
35
11
1
35
98
Ethernet communication.
89
Battery management
The INGECON SUN STORAGE Power
Max features a highly advanced battery control technology, ensuring the
maximum life of the storage system.
The battery temperature could be
controlled at all times ensuring an enhanced lifespan of the accumulator.
This inverter is 100% compatible with
Ingeteams PV inverters.
Size (inches)
Integrated Accessories
Frequency Regulation
In the event of an underfrequency,
an additional power injection is needed. The battery inverter will provide
this extra power for a certain period
of time.
Active Power Reserve
Some of the energy stored can be
saved in order to feed it to the grid
during short periods of time when it
is needed.
Digital Q Compensation
The battery inverter can control the
reactive power output and it can inject reactive power into the grid also
during the night.
grid operator
SCADA
DC
AC
Public Grid
INGECON SUN
PV array
Modbus TCP.
Modbus TCP; OPC
DC
AC
Battery Bank
STORAGE PowerMax
-1
-2
-3
Filter
DC Pre-charge
Battery
input
+3
+2
+1
Inverter
...
AC Pre-charge
+15
...
L1
L2
L3
AC
output for
connection
to a MV
network
Optional
-15
Optional
Optional
99
Operating modes:
The INGECON SUN STORAGE PowerMax B Series inverters usually work in
combination with Ingeteams INGECON
SUN PV inverters and INGECON SUN
EMS Plant Controller. With such a schema both inverter types (PV and batteries) could inject active and reactive
power into the grid at the same time, resulting in a much more efficient system.
STORAGE PowerMax U
B Series
610TL U B220
830TL U B300
1000TL U B360
1070TL U B385
1110TL U B400
438 - 820 V
480 - 820 V
574 - 820 V
614 - 820 V
637 - 820 V
Input (DC)
Battery voltage range(1)
Maximum voltage(2)
1,050 V
Maximum current
2,000 A
Type of battery
1,00
0 Vdc
5 up to 15
Fuse dimensions
Type of connection
Input protections
Overvoltage protections
DC switch
Other protections
Output (AC)
Power @ 95 F / @ 122 F(3)
Current @ 95 F / @ 122 F
Short-circuit capability
Rated voltage
385 V IT System
400 V IT System
3,440 A @ 11 ms
220 V IT System
300 V IT System
360 V IT System
Frequency
50 / 60 Hz
Power Factor(4)
Power Factor adjustable
1,600 A / 1,472 A
1
Yes. Smax=609.7 kVA
Type of connection
Output protections
Overvoltage protections
AC breaker
Anti-islanding protection
Other protections
Features
Maximum efficiency
98.9%
98.9%
98.9%
98.9%
98.9%
CEC
98.5%
98.5%
98.5%
98.5%
98.5%
2,500 VA
60 W
18 kWh
General Information
Ambient temperature
Relative humidity (non-condensing)
Protection class
-4 F to +131 F
0 - 100%
NEMA 12 (Indoor) / NEMA 3 (Outdoor)
Max. altitude(7)
9,842 ft
Cooling system
Forced air with temperature control (230 V phase + neutral power supply)
Air volume
Noise emission
Marking
IEC 62116, UL1741, IEEE 1547, IEEE 1547.1, NEC CODE, Electric Rule 21: 2015
Notes: (1) Minimum voltage DC (VDC, min) for Vgrid,max = 1.1 p.u. and Power Factor=1 If Vgrid,max is higher than this value, the minimum voltage should be corrected as VDC, min * Vgrid,max / 1.1
(2)
Beyond 820 V, the maximum current decreases gradually (3) For each F of increase between 95 F and 122 F, the output power will be reduced at the rate of 0.22%. Over 122 F,
the output power will be reduced at the rate of 1% for each 1F of increase (4) For P out >25% of the rated power (5) For P out >25% of the rated power and voltage in accordance with IEC
61000-3-4 (6) Consumption from battery (7) Over 3,300 ft, temperature for rated power is reduced at the rate of 2.42 F for each 3,300 ft.
100
STORAGE PowerMax U
B Series
1170TL U B450 1400TL U B540 1500TL U B578 1560TL U B600 1600TL U B615 1640TL U B630
Input (DC)
Battery voltage range(1)
717 - 1,300 V
858 - 1,300 V
Maximum voltage(2)
917 - 1,300 V
952 - 1,300 V
975.5 - 1,300 V
999 - 1,300 V
1,500 V
Maximum current
2,000 A
Type of battery
1,50
0 Vdc
6 up to 15 (optional)
Fuse dimensions
Type of connection
Single copper bar (up to 30 cables) or multiple copper bars with fuse holders
Input protections
Overvoltage protections
DC switch
Other protections
Current @ 77 F / @ 122 F
540 V IT System
578 V IT System
Type of connection
600 V IT System
615 V IT System
630 V IT System
50 / 60 Hz
Power Factor(4)
Power Factor adjustable
3,440 A @ 11 ms
450 V IT System
Frequency
1,500 A / 1,250 A
Short-circuit capability
Rated voltage
1
Yes. Smax=1,169 kVA
<3%
Connection to copper bars
Output protections
Overvoltage protections
AC breaker
Anti-islanding protection
Other protections
Features
Maximum efficiency
98.9%
Euroefficiency
98.5%
2,500 VA
60 W
18 kWh
General Information
Ambient temperature
Relative humidity (non-condensing)
Protection class
-4 F to +131 F
0 - 100%
NEMA 12 (Indoor) / NEMA 3 (Outdoor)
Max. altitude(7)
6,562 ft (2,000 m)
Cooling system
Forced air with temperature control (230 V phase + neutral power supply)
Air volume
Noise emission
Marking
IEC 62116, UL1741, IEEE 1547, IEEE 1547.1, NEC CODE, Electric Rule 21: 2015
Notes: (1) Minimum voltage DC (VDC, min) for Vgrid,max = 1.1 p.u. and Power Factor=1 If Vgrid,max is higher than this value, the minimum voltage should be corrected as VDC, min * Vgrid,max / 1.1
(2)
Beyond 820 V, the maximum current decreases gradually (3) For each F of increase between 77 F and 122 F, the output power will be reduced at the rate of 0.37%. Over 122 F,
the output power will be reduced at the rate of 1% for each 1F of increase (4) For PAC>25% of the rated power (5) For PAC>25% of the rated power and voltage in accordance with IEC
61000-3-4 (6) Consumption from battery (7) Over 3,300 ft, temperature for rated power is reduced at the rate of 2.42 F for each 3,300 ft.
101
Output (AC)
paneles solares
DC
AC
Communication
tion to the sun, the available roof surface area, the presence of shading, etc.)
and other factors.
4.00
3.50
100%
Self-consumption
Power (kW)
3.00
2.50
2.00
1.50
1.00
0.50
104
Battery load
23:59
22:00
20:00
18:00
16:00
14:00
12:00
10:00
8:00
4:00
6:00
2:00
0:00
0.00
Self-consumed power
80%
60%
40%
20%
0%
0:00
2:00
4:00
6:00
8:00
10:00
12:00
14:00
16:00
18:00
20:00
22:00
Self-consumption
Direct self-consumption
Self-consumption without batteries:
Ingeteam Smart Industry
The Ingeteam Smart Industry offers a
non-storage solution, based solely on
PV inverters. This is valid for net metering systems and also for those countries in which it is not permitted to feed
any excess energy produced into the
public grid. In this second case, which
is the most problematic in technical
terms, Ingeteam has implemented an
Self-consumption systems are more attractive and cost-effective when generation and consumption occur at the same
time, given the fact that the energy produced can then be consumed on the
spot, with no need for storage. For this
reason, the workplace is generally considered to be more conducive for systems
of this type, although it can also be of interest in certain domestic environments.
4.00
3.50
Self-consumption
100%
2.50
2.00
1.50
1.00
0.50
Self-consumed power
24:00
22:00
20:00
18:00
16:00
14:00
12:00
10:00
8:00
6:00
4:00
2:00
0.00
0:00
Power (kW)
3.00
80%
60%
40%
20%
0%
0:00
2:00
4:00
6:00
8:00
10:00
12:00
14:00
16:00
18:00
20:00
22:00
Self-consumption
105
Consumption management
Consumption management is the basis
of a truly effective energy management
system. Thanks to the potential-free
outputs it is possible to determine the
connection and disconnection times
for the various loads coupled to the system. This allows for the connection of
106
EMS Manager
Power supply
Input voltage
Nominal frequency
50 / 60 Hz
Power consumption
5-8W
Connectivity
Ethernet
RS-485
USB
Communication
interface with
other equipment
Ingeteam inverters
RS-485, Ethernet
Monitoring systems
Ethernet, GPRS
Power Meter
RS-485
Diesel + PV.
Diesel + PV+ Grid.
Multiple diesel gensets.
Standard 3-year warranty
2 x (250 V, 10 A)
42
110
150
Operating modes
On-line mode: a direct connection is
established with the INGECON SUN
EMS Manager device with all functionalities available to the user. Communication with the INGECON SUN
EMS Manager can either be made remotely through the Ingeteam servers
or directly by TCP / IP using the device IP address.
Off-line mode: users can view the
parameters configured and the historical data previously downloaded.
The INGECON SUN EMS Tools software is the PC application for the monitoring and configuration of self-consumption systems governed by the
INGECON SUN EMS Manager.
Configure the
INGECON SUN EMS Manager.
Individually configure each PV
plant inverter and other devices.
Control the loads.
View the plant wiring diagrams
and communications network.
View the production data.
Start-up and manage the
various PV plants from a PC.
Data capture, save a file to the
disc and get a graphic display
of the historical data.
Step 1
Installation of the software
Step 2
Configuration of the
INGECON SUN EMS Manager
Step 3
Plant configuration
and start-up
107
108
grid operator
SCADA
DC
PV array
AC
Public Grid
INGECON SUN
DC
AC
Modbus TCP.
Modbus TCP; OPC
DNP3; Modbus TCP/RTU;
IEC 60870-5-101/104.
Battery Bank
Operating mode
For the control, the INGECON SUN EMS
Plant Controller takes the following data:
Active power, reactive power, voltage and frequency at the connection point, provided by the integrated
measurement unit.
Grid operator requirements. To establish references for parameters such as
voltage at the point of connection, active and reactive power, power ramps,
active power reserve, etc. These requirements can be predetermined
either by the grid operator or by the
plant operator or dynamically modified through an external setpoint.
109
Optional
Standard version
Premium version
Regulation types
Production Control
Some of the active power control functions that can be implemented in the INGECON SUN EMS Plant Controller are:
Grid Support
Some of the reactive power control functions that can be implemented in the INGECON SUN EMS Plant Controller are:
INCLUDED ITEMS
PLC.
Power meter.
Communications switch.
Power supply.
Protections.
SYSTEM FEATURES
Digital Q compensation.
On-demand production.
Ramp rate control.
Power factor control.
Automatic voltage regulation.
COMPATIBILITY
Premium version
Power Analyzer
Voltage and current metering accuracy
10 mHz(1)
Class 0.5 S
Class 1 S
Class 0.5 S
0 ... 5 A
Other measurements
Optional
Redundancy
Not available
Optional
Power Supply
Voltage supply
Typical consumption
33 W
120 W(2)
Maximum consumption
50 W
280 W(2)
Input fuse
6.3 A
20 min(3)
Redundancy
Not available
Optional
Communication
Standard protocols
Compatible protocols
Outer connectivity
Managed communication
Redundancy
Optional
Yes, with SNMP v1/2/3, VLAN, DHCP, Flow control, STP, MAC filter
Not available
Optional
Regulation
On-Demand Production, Active Power Reserve, Ramp Rate Control, Energy Time Shifting, Peak Shaving
Grid Support
Digital Q Compensation, Power Factor Control, Automatic Voltage Regulation, Voltage Droop Control, Power Oscilations Damping
(4)
Active power
PF limitation curve
QV limitation curve, QP limitation curve
Reactive power
O&M Functions
Datalogger
Others
Web server
CPU
Typical processing time
10 ms
Clock
Surveillance system
Redundancy
Not available
Optional
General Data
Dimensions (H/W/D)
Weight
40 kg
150 kg
Protection class
IP65
Impact resistance
Overvoltage protection
Installation
IP55
IK10
Type 2
Wall
Ground
Operating temperature
Storage temperature
10 - 95%
Maximum altitude(5)
2,000 m
Marking
Standards
CE
IEC 61000-4-30, IEC 62586-1, IEC 61131-3, IEC 60204-1, IEC 61439
Notes: (1) For voltages greater than 30% of the nominal voltage (2) Values measured with the highest redundancy level (3) If the installation features an energy storage system. Otherwise, the autonomy
is 2 seconds (4) For other configurations, please contact Ingeteams solar sales department (5) For installations beyond the maximum altitude, please contact Ingeteams solar sales department.
111
Production Control
PV-DIESEL SOLUTIONS
Solar PV
Diesel
2002
2013
2020
PV-Diesel Solutions
Integration of photovoltaics into diesel grids
The power generation from diesel gensets plays a key role for industrial companies and rural communities all over
the world, especially in remote regions
without a good grid infrastructure. They
permit to create simple off-grid networks
with a moderate initial investment.
0.60
/ kWh
/ kWh
0.45
0.40
0.35
0.50
0.40
0.30
0.20
0.30
0.25
0.20
0.15
0.10
0.10
0.05
0.00
0.00
0.40
0.60
0.80
1.00
1.20
1.40
1.60
1,60
1.80
700
900
1.100
/l
PVCapEX= 2 - 1.5 /Wp (> 1 MW); PVOpEx:1.5% annual; Degradation: 0.4 annual; PR=0.85;
Diesel CapEX=0.3 /W (> 1 MW); O&M=3% annual; Diesel cost: actual price + 3% annual
Interest loan= 6.4%; 12 years
Time: 20 years
114
1.300
1.500
1.700
2.00 /Wp
1.50 /Wp
1.900
2.100
2.300
2.500
PV + Diesel generation
400
Power (kW)
350
300
PV
250
27%
200
150
100
50
Gen
Gen 1 = 400 kW
73%
00:00
21:00
22:30
19:30
18:00
13:30
15:00
13:30
12:00
10:30
7:30
9:00
6:00
4:30
1:30
3:00
0:00
PV
Multiple generators
400
350
300
Gen 1 = 200 kW
22:30
00:00
21:00
19:30
18:00
13:30
15:00
13:30
10:30
7:30
9:00
12:00
Gen 2 = 200 kW
PV-Diesel Solutions
Gen 1 = 400 kW
6:00
00:00
22:30
21:00
19:30
18:00
15:00
13:30
13:30
12:00
10:30
9:00
7:30
6:00
4:30
0
3:00
50
0
1:30
100
50
4:30
150
100
1:30
150
250
200
3:00
250
200
0:00
Power (kW)
350
300
0:00
Power (kW)
400
250
200
150
100
50
Gen 1 = 200 kW
00:00
22:30
21:00
19:30
18:00
15:00
13:30
13:30
12:00
10:30
9:00
7:30
6:00
4:30
3:00
1:30
0
0:00
Power (kW)
300
Gen 2 = 200 kW
115
Ingecon EMS
Manager
AC
DC
Loads
PV array
INGECON SUN
AC
Diesel Generator
Wattmeter
Operating mode
In those cases in which one or more gensets are operating permanently to satisfy the energy demand, the Ingecon
SUN EMS Manager can be used to
control the PV inverters.
System features:
Minimum diesel load
It guarantees that the diesel generator does not operate under a minimum load level, in order to ensure a
longer engine life.
Monitoring
The installation can be monitored by
using the software Ingecon SUN
EMS Tools. Also, an internal datalogger allows to store more than 30
days historical data.
Load control
The Ingecon SUN EMS Manager
allows switching loads on when the
genset load level is low and there is a
PV generation surplus.
116
SCADA
DC
AC
Loads
PV array
INGECON SUN
AC
Diesel Generator 1
AC
Operating mode
In those cases in which an external diesel controller determines the number
of operating gensets, the Ingecon
SUN EMS PV-Diesel Controller is used
to guarantee a proper PV integration in
the diesel grid.
Photovoltaic inverters inject current to
the diesel grid, being detected by the
genset as a load reduction. Ingecon
SUN EMS PV-Diesel Controller monitors
the genset units, obtaining which ones
are operating as well as their load level.
This information is used to determine the
maximum power that the solar inverters
can supply in order to guarantee the system stability, i.e. in a cloud shading event.
System features:
Minimum diesel load
It guarantees that the diesel generators do not operate under a minimum
load level, in order to ensure a longer
engine life.
PV-Diesel Solutions
Diesel Generator 2
SCADA
AC
DC
Loads
PV array
INGECON SUN
AC
DC
Batteries
INGECON SUN STORAGE
Optional
AC
Public grid
AC
Diesel Generator 1
Diesel Generator 2
118
In these installations, the storage system has to provide the energy needed
for the genset start-up.
The system can be monitored via SCADA or dedicated software.
The Ingecon SUN EMS PV-Diesel
Controller features an auto-learning algorithm that allows maximizing the PV
PV-Diesel Solutions
Operating mode
Photovoltaic inverters inject current to
the diesel grid, being detected by the
genset as a load reduction. Ingecon
SUN EMS PV-Diesel Controller monitors
the loads and determines the maximum
PV power that can be injected into the
diesel grid. Furthermore, in a cloud shading event, the Ingecon SUN EMS
PV-Diesel Controller together with the
battery inverters Ingecon SUN STORAGE PowerMax, reduce the output
power with a established ramp rate,
that will allow to the diesel controller to
switch-on the required generators.
Available PV power
119
Accessories
MULTI-OPTIONS FOR PV PLANT CONTROL
AND MONITORING
160 / 320
String current monitoring
The INGECON SUN StringControl is a
device for measuring each PV generator string current and detecting defective string currents through INGECON
SUN Manager software, INGECON
SUN SCADA and / or other monitoring
systems. String currents can be monitored through the RS-485, Ethernet
Modbus / TCP and GSM / GPRS communication interfaces.
Flexibility
Available in models ranging from 16
to 32 inputs and equipped with PV
connectors type 4 (standard) or cable glands inlet connections, the INGECON SUN StringControl provide
the maximum flexibility and expandability in system design. The compact
and rugged IP65 enclosure is designed
Main features
122
Up to 16 pairs of DC fuses.
StringControl
StringControl 160
StringControl 320
16
32(1)
Input
Max number of connectable input strings
Maximum number of measurable channels
Maximum current per string(2)
Number of protection fuses
Type of fuses
Available fuses
16
20 A
2 x 16
2 x 16
10 A, 12 A, 15 A, 16 A (15 A standard)
20 A, 25 A, 30 A (30 A standard)
Maximum DC voltage
Inlet connections
16
10 A
1,000 V
1,000 V
Output
Maximum total current(2)
Outlet connections
160 A
320 A
250 A (standard)(3)
450 A (standard)(4)
Communication
Communication interface
Protection rating
IP65
IP65
Impact strength
IK10
IK10
-20 C to +55 C
-20 C to +55 C
Inlet connection
Grounding
Grounding connection
General Information
Enclosure type
Ambient temperature
Relative humidity (non-condensing)
0 to 95%
0 to 95%
3,000 m a.s.l.
3,000 m a.s.l.
Maximum altitude(5)
DC switch handle
Weight
25 kg
25 kg
Marking
CE
LV Switchgear standards
Class II equipment
Notes: (1) Type 4 Y connectors for parallel connection of two string cables to the same input channel not included in the supply (3) Up to 50 C (3) 250 A disconnect rating for DC isolating
switch with remote tripping (optional) (4) 450 A disconnect rating for DC isolating switch with remote tripping (optional) (5) Over 1,000 m temperature for maximum current is reduced
at the rate of 4.5 C for each 1,000 m. For installations beyond the maximum altitude, please contact Ingeteams solar sales department.
Accessories
540
Size (mm)
72
23
123
Main features
Protections
OPTIONAL ACCESORIES
Up to 32 pairs of DC fuses.
124
StringBox
1,000 V
1,500 V
StringBox 160 StringBox 240 StringBox 320 StringBox 160 StringBox 240 StringBox 320
Input
Maximum number of input strings
16
24
32
16
24
32
2 x 24
2 x 32
10 A
12 A
2 x 16
2 x 24
Type of fuses
2 x 32
2 x 16
Maximum DC voltage
Inlet connections
1,000 V
1,500 V
M32 cable glands (n.4 cables entry diameter: 3.5 to 7 mm for each
cable gland) with Direct connection on fuse holders
M32 cable glands (n.4 cables entry diameter: 3.5 to 7 mm for each
cable gland) with Direct connection on fuse holders
Output
Rated total current
160 A
240 A
320 A
160 A
240 A
320 A
192 A
288 A
384 A
192 A
288 A
360 A
Outlet connections
200 A
315 A
400 A
315 A
315 A
400 A
Grounding
Grounding connection
General Information
Enclosure type
Protection rating
IP65
Impact strength
IK10
-20 C to +55 C
0 to 100%
2,000 m a.s.l.
Maximum altitude(2)
DC switch handle
Consumption
0W
Weight
27 kg
43 kg
44 kg
Marking
32 kg
46 kg
48 kg
CE
LV Switchgear standards
Class II equipment
Notes: (1) Over 50 C ambient temperature, the current will be reduced at the rate of 3.5% every C up to 55C.
(2)
Accessories
835
1,035
Size (mm)
83
63
StringBox 160
30
30
125
Outdoor installation
The Ingecon Sun WeatherBox has
been especially designed for outdoor
installation, with a protection rating of
IP65. Sensors can be connected to
measure a number of parameters such
Easy communication
Ingecon Sun WeatherBox acts as
one more slave in the communication
network, in addition to the PV inverters.
Communication with the Ingecon Sun
WeatherBox can be established either
by RS-485 or Ethernet boards.
Ethernet
146
340 g.
16
0
75
126
Wi-Fi
board
Ethernet-TCP
Board
RS-485
Board
Accessories
127
SOFTWARE FEATURES
Individual configuration
of each PV plant inverter.
On-line display of the
inverter internal variables.
Display of all the plant
inverters on a single
screen.
Irradiance*.
Ambient temperature*.
Alarm status.
Wind speed*.
128
Module temperature*.
Accessories
With the INGECON SUN Monitor software, PV plant data can be accessed
from any PC with an Internet connection (www.ingeconsunmonitor.com). Its
ease of access facilitates owner, installer or promoter plant control. This software provides information on the PV
129
PV plant dimensioning
The new INGECON SUN Planner software offers the possibility of optimally
customising each specific project. In
just three fast, simple steps users can
correctly dimension a PV plant, by
selecting the type of PV module and
Step 1
Select the INGECON SUN
Inverter
130
Step 2
Select the
PV panel
Step 3
Dimensioning of the PV
plant completed
Remote Communication
Some possible communication protocols
Interbus-S.
Profibus-DP.
CAN.
OPC DA & OPC XML Data Client
and Server.
IEC 61850 Client and Server.
IEC 61400-25 Client and Server.
Accessories
131
1Play
TL M
1Play
TL U M
3Play
TL
3Play
TL M
3Play
TL U M
PowerMax
TL B
PowerMax
TL U B
PowerMax
TL X
PowerMax
TL M
Protections
Galvanic isolation DC-AC
Reverse Polarity
Input overvoltage
(type 2 surge arresters)
Output overvoltage
(type 2 surge arresters)
Output shortcircuits and overloads
Insulation failure DC
Insulation failure AC
Anti-islanding with automatic shutdown
DC fuse-holders
DC fuses
DC switch
AC circuit breaker
Accessories
Multicontact 4
Potential-free contact
Self-consumption kit
Self-consumption kit with EMS Manager
Heating kit (-30 C / -22 F)
Grounding kit
Sync kit
Communications
RS-485
Ethernet
3G Router
USB
Wi-Fi
Plant power control(2)
Software
INGECON SUN Manager
for plant management
INGECON SUN Monitor
for plant monitoring
Notes: (1) For inter-inverter synchronization, request a quote (2) Equipment prepared. An external controller is required
integrates digital outputs and analogue inputs (5) AC protections.
132
(3)
(4)
It also
STORAGE
1Play
STORAGE
1Play TL
STORAGE
Power
STORAGE
PowerMax
TL B
STORAGE
PowerMax
TL U B
STORAGE
PowerMax
TL X
EMS
Manager
EMS
Plant
Controller
SUN
WeatherBox
SUN
StringControl
Protections
Galvanic isolation DC-AC
Reverse Polarity
Input overvoltage
(type 2 surge arresters)
Output overvoltage
(type 2 surge arresters)
Output shortcircuits and overloads
Insulation failure DC
Insulation failure AC
Anti-islanding with automatic shutdown
DC fuse-holders
DC fuses
DC switch
AC circuit breaker
Accessories
Multicontact 4
Potential-free contact
Self-consumption kit
Self-consumption kit with EMS Manager
Heating kit (-30 C / -22 F)
Grounding kit
Sync kit
Communications
RS-485
Ethernet
3G Router
USB
Wi-Fi
Plant power control(2)
Software
INGECON SUN Manager
for plant management
Accessories
Integrated
Optional
Not available
133
TRAINING COURSES
On-site courses
General and specific, commercial and technical; free and subsidised. Get more
information on the training available at: www.ingeconsuntraining.com
Tailored courses
Tell us your needs and well design a customised training program. We can even
give the course at your facilities.
Live webinars
You can also do a course from your own home or office. You simply need a computer,
Internet connection and a microphone headset.
ADDITIONAL SUPPORT
www.ingeconsuntraining.com
[email protected]
Visits
Youre welcome to visit our facilities. Wed like you to get to know our equipment
right from its origins.
Audiovisual material
Our website offers access to videos, presentations and technical documentation
with relevant information on technological developments, technical support etc.
FAQ
The FAQ section on our website allows you to check out the answers to the main
doubts raised by our customers. You even have the opportunity to ask us about
any other doubts or question you may have.
Technical articles
Keep up-to-date with technical articles on the very latest technological developments achieved by our team of engineers.
136
Efficiency
Our goal is to ensure that our inverters
deliver the highest energy efficiency rates possible. Well help you to get the
most out of our products.
Certification
Our training courses are certified by the
most reputed solar education and renewable energy training organizations
worldwide.
Flexibility
We can adapt to suit your own particular needs and circumstances, with
customised courses, either online or
face-to-face, depending on your own
specific requirements.
Excellence
Our training personnel are involved in
R&D work, and are therefore always upto-date with the very latest PV technology.
137
Choose from
a complete portfolio
of service solutions
At Ingeteam, as well as the design
and manufacture of PV plant Inverters, we are also concerned with
providing an excellent maintenance service to guarantee an increased equipment lifespan and maximum performance.
Extended warranty
140
Commissioning
Spares guarantee
Online supervision
Availability
Maintenance
Ingeteam Service
We offer you 7 service
modules to cover each
and every PV inverter
maintenance requirement. Select those modules that are best suited to your system and
combine them to ensure a reliable operation.
Manufacturers protocol.
Troubleshooting during
commissioning.
Online Supervision:
1
2
141
TAILORED SOLUTIONS
As well as designing and manufacturing the power and control electronics
for PV plants and other renewable energy generation systems, Ingeteam
has also been concerned with offering the best possible maintenance service to ensure optimum plant performance and continuous operation.
Maximum
performance
Guaranteed
optimization
Risk-free
financial returns
The PV plant must achieve maximum performance, with as few interruptions as possible. Get the most
from your PV plant through correct
maintenance.
142
Our strategy is based on an optimum all-inclusive maintenance policy, to ensure the continuous operation of your plant.
Spares always
on hand
True
adaptability
Operation
Maintenance
Spares
Production guarantee
All-incl
usive maintenance
143
referencEs
OVER 5 GW OF PV INVERTERS
SUPPLIED WORLDWIDE
Ingeteam boasts a long, proven
track record in the industrial and
energy sectors, which stretches
back to 1972, clearly demonstrating the companys ongoing policy
of technological development. In
the nineties, Ingeteam became
more involved in the development
of electrical and control systems
specific to the renewable energies
sector; this was initially directed at
the wind power and hydroelectric
sectors and then, from 2000 onwards, our company broadened its
scope to encompass the PV solar
energy sector as well.
1. ISOLUX CORSN
PV plant at San Bellino (Italia)
70 MWp (60 INGECON SUN PowerMax)
146
QUADRAN
2. PV plant at Roquefort (France)
9.7 MWp (8 INGECON SUN PowerMax)
ACCIONA SOLAR
3. PV array at Amareleja (Portugal)
46 MWp (70 INGECON SUN PowerMax)
4. Akuo Energy
PV installation with energy storage in
La Runion island (France)
9 MW PV + 9 MWh batteries
(10 INGECON SUN PowerMax,
6 INGECON SUN STORAGE PowerMax)
FRV
2. Royalla Solar Farm (Australia)
20 MW (10 INGECON SUN PowerStation)
147
REFERENCES
148
6. SINERGIA SISTEMI
7. G
eneral Electric and Moser Baer Clean Energy
10
11
12
9. CTF-Solar GmbH
11. EFACEC
149
REFERENCES
13
14
15
150
15. GRANSOLAR
16. SOLARCENTURY
16
17
18
19
17. EOSOL
18. ASSYCE
19. CEGELEC
151
REFERENCES
20
21
22
152
20. SUNEDISON
21. MARTIFER
Domestic installation at
New Jersey (USA)
25 kW (5 INGECON SUN Lite TL U)
23
24
25
26
24. SYDIS
25. SUNPOWER
153
REFERENCES
27
28
29
154
29. ABM
30
31
32
33
30. ACCIONA
32. Enerpro
Diesel-PV installation in
Baltra airport (Galapagos, Ecuador)
75 kW (3 INGECON SUN Smart U)
155