CT (ACT)
SUPER MINIATURE
TWIN TYPE
AUTOMOTIVE RELAY
17.4
.685
14
.551
13.5
.531
Twin type (8 terminals)
7.2
.283
17.4
.685
13.5
.531
CT RELAYS (ACT)
FEATURES
TYPICAL APPLICATIONS
Small & slim size
Twin type: 17.4(L)14.0(W)13.5(H)mm
.685(L).551(W).531(H)inch
Slim 1c type: 17.4(L)7.2(W)13.5(H)mm
.685(L).283(W).531(H)inch
Twin (1 Form C 2)
Forward/reverse motor control is possible
with a single relay.
Simple footprint enables ease of PC
board layout
Power windows
Auto door lock
Power sunroof
Electrically powered mirrors
Powered seats
Lift gates
Slide door closers, etc.
(for DC motor forward/reverse control
circuits)
10 terminals layout
mm inch
Slim 1c type
RoHS Directive compatibility information
http://www.nais-e.com/
Contact
terminal
Coil
terminal
= 8 terminals
SPECIFICATIONS
Contact
Characteristics
Arrangement
Contact material
Initial contact resistance (Initial)
(By voltage drop 6 V DC 1 A)
Nominal switching
capacity
Rating
Max. carrying current
(N.O.)
Min. switching capacity#1
Mechanical (at 120 cpm)
Resistive load
Expected life
(min. operation) Electrical
Motor load
1 Form C2,
1 Form C
Ag alloy (Cadmium free)
Typ. 7 m (N.O.)
Typ. 10 m (N.C.)
N.O.: 20 A 14 V DC
N.C.: 10 A 14 V DC
35 A for 2 minutes,
25 A for 1 hour
(14 V, at 20C 68F)
30 A for 2 minutes,
20 A for 1 hour
(14 V, at 85C 185F)
1 A 12 V DC
Min. 107
Min. 105*1
Min. 2105*2 (free)
Min. 105*3 (lock)
Coil
Nominal operating power
800 mW
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Max. operating speed
(at nominal switching capacity)
Initial insulation resistance*4
Between open
Initial
contacts
breakdown
Between contacts
5
voltage*
and coil
Operate time*6
(at nominal voltage) (at 20C 68 F)
Release time*6
(at nominal voltage) (at 20C 68 F)
Functional*7
Shock resistance
Destructive*8
Functional*9
Vibration
resistance
Destructive*10
Ambient
Conditions for
operation, transport and temp
storage*11 (Not freezing
and condensing at low Humidity
temperature)
6 cpm
Min. 100 M (at 500 V DC)
500 Vrms for 1 min.
500 Vrms for 1 min.
Max. 10ms (Initial)
Max. 10ms (Initial)
Min. 100 m/s2 {10G}
Min. 1,000 m/s2 {100G}
10 Hz to 100 Hz,
Min. 44.1m/s2 {4.5G}
10 Hz to 500 Hz,
Min. 44.1m/s2 {4.5G}
40C to +85C
40F to +185F
5% R.H. to 85% R.H.
Approx. 8.0g .28oz (Twin type)
Approx. 4.0g .14oz (Slim 1c type)
Mass
Remarks
*1 At nominal switching capacity, operating frequency: 1s ON, 9s OFF
*2 N.O.: at 5 A (steady), 25 A (inrush)/N.C.: at 20 A (brake) 14 V DC, operating
frequency: 0.5s ON, 9.5s OFF
*3 At 25A 14 V DC (Motor lock), operating frequency: 0.5s ON, 9.5s OFF
*4 Measurement at same location as Initial breakdown voltage section
*5 Detection current: 10mA
*6 Excluding contact bounce time
*7 Half-wave pulse of sine wave: 11ms; detection: 10s
*8 Half-wave pulse of sine wave: 6ms
*9 Detection time: 10s
*10 Time of vibration for each direction;
X, Y, direction: 2 hours
Y
X
Z direction: 4 hours
Z
*11 Refer to Conditions for operation, transport and storage mentioned in AMBIENT
ENVIRONMENT .
Please inquire if you will be using the relay in a high temperature atmosphere
(110C 230F).
* If the relay is used continuously for long periods of time with coils on both sides
in an energized condition, breakdown might occur due to abnormal heating
depending on the carrying condition. Therefore, please inquire when using with
a circuit that causes an energized condition on both sides simultaneously.
All Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd.
CT (ACT)
ORDERING INFORMATION
Ex.
CT
Product name
CT
12
Contact arrangement
Coil voltage (V DC)
1: 1 Form C
2: 1 Form C 2 (8 terminals type)
5: 1 Form C 2 (10 terminals type)
12: 12
Standard packing; 1 Form C: Carton(tube package) 30pcs. Case 1,500pcs.
1 Form C 2: Carton(tube package) 30pcs. Case 900pcs.
TYPES AND COIL DATA (at 20C 68F)
Contact
arrangement
1c
1c 2
(8 terminals type)
1c 2
(10 terminals type)
12
Pick-up
voltage,
V DC
(Initial)
Max. 7.2
Drop-out
voltage,
V DC
(Initial)
Min. 1.0
ACT212
12
Max. 7.2
ACT512
12
Max. 7.2
Part No.
Nominal
voltage,
V DC
ACT112
Coil
resistance,
Nominal operating
current,
mA
Nominal
operating power,
mW
Usable
voltage range,
V DC
18010%
66.710%
800
10 to 16
Min. 1.0
18010%
66.710%
800
10 to 16
Min. 1.0
18010%
66.710%
800
10 to 16
* Other pick-up voltage types are also available. Please contact us for details.
DIMENSIONS
17.4
.685
mm inch
14
.551
1. Twin type (8 terminals)
PC board pattern (Bottom view)
13.5
.531
0.4
.016
9.5
.374
6
.236
Max. 1.0
.039
3.5
.138
3
6.8 .118
.268 3.15
.124
*A
0.4
.016
1
.039
1
.039
Sealed by epoxy resin
1.25
.049
6
.236
0.8
.031
0.4 0.4
.016 .016
Pre-soldering
0.3
.012
9.5
.374
1
.039
4.3
.169
15
.591
1.45
.057
Schematic (Bottom view)
Dimension:
Tolerance
Max. 1mm .039 inch:
0.1 .004
1 to 3mm .039 to .118 inch: 0.2 .008
Min. 3mm .118 inch:
0.3 .012
17.4
.685
COIL
COM
0.4
.016
1.25
.049
NO
COIL
PC board pattern (Bottom view)
9.5
.374
6
.236
Max. 1.0
.039
1
.039
1
.039
9.5
.374
6
.236
4.3
.169
2.5
.098
4.3
.169
3.15
.124
0.65
6.8 .026
.268 3.15
.124
*A
0.8
.031
0.3
.012
0.4 0.4
.016 .016
Pre-soldering
+0.1
0.65
.026
4-1.1 0 dia
4-.043 +0.04
dia
0
15
.591
+0.1
0
+0.04
0
6-1.4 dia
6-.055
dia
Sealed by epoxy resin
Tolerance: 0.1 .004
4.3
.169
2.5
.098
3.15
.124
0.65
6.8
.026
.268 3.15
.124
1.45
.057
0.65 1
.026 .039
NC
COM
14
.551
13.5
.531
0.4
.016
3.5
.138
4-1.1 0 dia
4-.043 +0.04
dia
0
Tolerance: 0.1.004
* Dimensions (thickness and width) of terminal specified in this catalog is measured before pre-soldering.
Intervals between terminals is measured at A surface level.
2. Twin type (10 terminals)
+0.1
15
.591
+0.1
4-1.4 0 dia
4-.055 +0.04
dia
0
4.3
.169
2.5
.098
3
6.8 .118
.268 3.15
.124
4.3
.169
2.5
.098
4.3
.169
4.3
.169
15
.591
Schematic (Bottom view)
Dimension:
Tolerance
Max. 1mm .039 inch:
0.1 .004
1 to 3mm .039 to .118 inch: 0.2 .008
Min. 3mm .118 inch:
0.3 .012
* Dimensions (thickness and width) of terminal specified in this catalog is measured before pre-soldering.
Intervals between terminals is measured at A surface level.
All Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd.
NO
COIL
NC
COM
NO
COIL
COM
NC
CT (ACT)
3. Slim 1c type
mm inch
7.2
.283
17.4
.685
PC board pattern (Bottom view)
3-1.4 dia.
3-.055 dia.
13.5
.531
0.4
.016
Max. 1.0
.039
9.5
.374
6
.236
4.3
.169
3.15
.124
3.5
.138
*A
0.4
1
1
.016
.039
Sealed by epoxy resin .039
9.5
1.25
6
.374
.049
.236
1
.039
3.15
.124
1.45 0.65
.057 .006
+0.1
0.8
.031
0.3
.012
0.65
.026
0.4
.016
2-1.1 0 dia.
2-.043 +0.04
dia.
0
15
.591
0.4
.016
Tolerance: 0.1.004
Pre-soldering
Schematic (Bottom view)
4.3
.169
15
.591
Dimension:
Tolerance
Max. 1mm .039 inch:
0.1 .004
1 to 3mm .039 to .118 inch: 0.2 .008
Min. 3mm .118 inch:
0.3 .012
NO
COIL
NC
COM
* Dimensions (thickness and width) of terminal specified in this catalog is measured before pre-soldering.
Intervals between terminals is measured at A surface level.
EXAMPLE OF CIRCUIT
Forward/reverse control circuits of DC
motor for power windows
NO
COM
12 V DC
COM
NO
NC
NC
SW A
SW B
M : Power window motor
REFERENCE DATA
1-(1). Coil temperature rise (at room
temperature
1-(2). Coil temperature rise (at 85C 185F)
Sample: ACT212, 3pcs.
Contact carrying current: 0A, 10A, 20A
Sample: ACT212, 3pcs.
Contact carrying current: 0A, 10A, 20A
140
2. Max. switching capability (Resistive load,
initial)
(N.O. side: room temperature)
60
140
120
10A
0A
80
60
20
0
14
16
Coil applied voltage, V
0A
60
20
12
10A
80
40
3. Ambient temperature and operating voltage
range
50
40
30
20
10
0
12
14
16
Coil applied voltage, V
10
20
30
40
Switching current, A
50
4. Distribution of pick-up and drop-out voltage
5. Distribution of operate and release time
Sample: ACT212, 40pcs.
Sample: ACT212, 40pcs.
* Without diode
40
50
35
35
Pick-up voltage
Drop-out voltage
20
Operate time
Release time
40
30
Frequency
Coil applied voltage, VDC
100
40
20A
25
20
Quantity, n
100
Switching voltage, VDC
120
Temperature rise, C
Temperature rise, C
20A
30
20
15
20
15
25
10
10
10
5
Pick-up voltage (Cold start)
0
40 20 0
20 40 60 80 85 100 120
Ambient temperature, C
0 1 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5
Voltage, V
All Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd.
0
1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0
Operate and release time, ms
CT (ACT)
Circuit:
Sample
Change of pick-up and drop-out voltage
10
Change of contact resistance
50
Contact welding: 0 time
Miscontact: 0 time
8
Pick-up voltage
Max.
X
Min.
4
Drop-out voltage
Max.
X
Min.
10
No. of operations, 104
Contact resistance, m
Sample: ACT212, 3pcs.
Load: 5A steady, Inrush 25A, 14V DC
Brake current: 13A 14V DC,
Power window motor actual load (free condition)
Operating frequency: (ON : OFF = 0.5s : 9.5s)
Ambient temperature: Room temperature
Pick-up and drop-out voltage, V
6-(1). Electrical life test (Motor free)
40
30
20
10
20
Max.
X
Min.
0
10
20
No. of operations, 104
Load current waveform
Inrush current: 25A, Steady current: 6A
Brake current: 13A
10A
100ms
6-(2). Electrical life test (Motor lock)
Change of pick-up and drop-out voltage
Change of contact resistance
Sample: ACT212, 3pcs.
Load: 25A 14V DC
Switching frequency: (ON : OFF = 0.5s : 9.5s)
Ambient temperature: Room temperature
Sample
50
Contact welding: 0 time
Miscontact: 0 time
Pick-up voltage
Max.
X
Min.
Drop-out voltage
Max.
X
Min.
5
No. of operations, 104
10
Contact resistance, m
Pick-up and drop-out voltage, V
10
Circuit:
40
30
20
Max.
X
Min.
10
Load current waveform
5A
100ms
All Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd.
5
No. of operations, 104
10
CT (ACT)
6-(3). Electrical life test (Motor lock)
Change of pick-up and drop-out voltage
Sample: ACT212, 3pcs.
Load: 20A 14V DC,
door lock motor actual load (Lock condition)
Switching frequency: (ON : OFF = 0.3s : 19.7s)
Ambient temperature: Room temperature
Change of contact resistance
50
Side1
M M M M M M
Side2
9
8
7
Pick-up voltage
Max.
X
Min.
5
4
Drop-out voltage
3
2
Contact resistance, m
Sample
Pick-up and drop-out voltage, V
10
Circuit:
Max.
X
Min.
40
30
20
10
1
0
10
No. of operations, 104
Relay 1
Relay 2
0.3s
9.7s
0.3s
9.7s
20s (1 cycle)
Load current waveform
5A
100ms
For Cautions for Use, see Relay Technical Information.
All Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd.
5
No. of operations, 104
Max.
X
Min.
10