above the shoulder of the cone tip. See Fig. 1. The balance of the data, therefore, also must be evaluated. There have been methods proposed to estimate hydraulic conductivity
from excess pore water pressure measurements (10, 14, 16).
Dissipation Tests:
In general, since the groundwater ows primarily through sands and not clays, modeling the ow through the sands is most critical. The pore pressure data also can be monitored
with the sounding halted. This is called a pore pressure dissipation test. A rapidly dissipating pore pressure indicates the presence of an aquifer while a very slow dissipation
indicates the presence of an aquitard. Fig. 6 shows one proposed relationship between dissipation time, soil type, and hydraulic conductivity (11).
A pore pressure decay in a sand is almost instantaneous. The permeability (hydraulic conductivity), therefore, is very dicult to measure in a sand with a cone penetrometer. As a
result, until recently the cone penetrometer was not used very often for measuring the permeability of sands in environmental applications. Newly developed hardware and
software now allow for high resolution data collection even in rapidly dissipating sand formations (12).
A thorough study of groundwater ow also includes determining where the water cannot ow. Cone penetrometer pore pressure dissipation tests can be used very eectively to
study the permeability of aquitards (13).
The pore pressure data also can be used to estimate the depth to the water table or identify perched water zones. This is accomplished by allowing the excess pore water
pressure to equilibrate and then subtract the appropriate head pressure. Due to high excess pore pressures being generated, typical pore pressure transducers are congured to
measure pressures up to 3.5 MPa. Since transducer accuracy is a function of maximum range, this provides a relative depth to water level accuracy of about 150 mm. Better
accuracy can be achieved if the operator allows sucient time for the transducer to dissipate the heat generated while penetrating dry soil above the water table. Lower
pressure transducers are sometimes used just for the purpose of determining the depth to the water table more accurately. For example, a 175-KPa transducer would provide
accuracy that is better than 10 mm. Incorporation of a temperature transducer and appropriate calibration allows for high precision and rapid data collection. Caution must be
used, however, to prevent these transducers from being damaged due to a quick rise in excess pressure. Some newer systems allow for large burst pressure protection without
hysteresis, which enables users to collect data in highly stratied environments without as much concern for transducer damage.
When coupled with appropriate models, three dimensional gradient can be derived from nal pressure values collected from multiple CPT locations. Once gradient distributions
have been derived, and hydraulic conductivity and eective porosity distributions have been generated, seepage velocity distributions can be derived and visualized. This type
of information is critical to environmental investigations and remediation design. If contaminant concentration distributions are known, the same software can be used to derive
three dimensional distributions of contaminant mass ux.
For a complete description of a typical geotechnical electronic cone penetrometer test, see Test Method D5778.
This practice tests the soil in situ. Soil samples are not obtained. The interpretation of the results from this practice provides estimates of the types of soil penetrated.
Investigators may obtain soil samples from adjacent borings for correlation purposes, but prior information or experience in the same area may preclude the need for borings.
Certain subsurface conditions may prevent cone penetration. Penetration is not possible in hard rock and usually not possible in softer rocks, such as claystones and shales.
Coarse particles, such as gravels, cobbles, and boulders may be dicult to penetrate or cause damage to the cone or push rods. Cemented soil zones may be dicult to
penetrate depending on the strength and thickness of the layers. If layers are present which prevent direct push from the surface, rotary or percussion drilling methods can be
employed to advance a boring through impeding layers to reach testing zones.
Note 1The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities
used. Agencies that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing/sampling/inspection/etc. Users of this standard are
cautioned that compliance with Practice D3740 does not in itself assure reliable results. Reliable results depend on many factors; Practice D3740 provides a means of evaluating
some of those factors.
Practice D3740 was developed for agencies engaged in the testing or inspection of soils and rock or both. As such, it is not totally applicable to agencies performing this
practice. However, users of this practice should recognize that the framework of Practice D3740 is appropriate for evaluating the quality of an agency performing this practice.
Currently there is no known qualifying national authority that inspects agencies that perform this practice.
FIG. 2 Simplied Soil Classication Chart for Standard Electric Friction Cone (Robertson and Campanella 1986) (9)
FIG. 3 Normalized Soil Classication Chart for Standard Electric Friction Cone (Robertson 1990) (9)
Zone
Range of Permeability
k (m/s)
Sensitive ne grained
3 10-9 to 3 10-8
Organic soils
1 10-8 to 1 10-6
Clay
1 10-10 to 1 10-9
1 10-9 to 1 10-8
1 10-8 to 1 10-7
1 10-7 to 1 10-6
1 10-5 to 1 10-6
1 10-5 to 1 10-4
Sand
1 10-4 to 1 10-3
-3
10
1 10-3 to 1
11
1 10-8 to 1 10-6
12
3 10-7 to 3 10-4
FIG. 4 Estimation of Hydraulic Conductivity from Non-Normalized CPT SBT Chart (9)
Zone
Range of Permeability
k (m/s)
Sensitive ne grained
3 10-9 to 3 10-8
Organic soils
1 10-8 to 1 10-6
Clay
1 10-10 to 1 10-9
Silt mixtures
3 10-9 to 1 10-7
Sand mixtures
1 10-7 to 1 10-5
Sands
1 10-5 to 1 10-3
1 10-3 to 1
1 10-8 to 1 10-6
1 10-8 to 1 10-6
FIG. 5 Estimation of Hydraulic Conductivty from Normalized CPT VSBT Chart (9)
FIG. 6 Proposed Relationship between T50 Dissipation Time, Soil Type, and Hydraulic Conductivity (12)
1. Scope
1.1 The electronic cone penetrometer test often is used to determine subsurface stratigraphy for geotechnical and environmental site characterization purposes (1). The
geotechnical application of the electronic cone penetrometer test is discussed in detail in Test Method D5778, however, the use of the electronic cone penetrometer test in
environmental site characterization applications involves further considerations that are not discussed. For environmental site characterization, it is highly recommended to use
the Piezocone (PCPT or CPTu) option in Test Method D5778 so information on hydraulic conductivity and aquifer hydrostatic pressures can be evaluated.
1.2 The purpose of this practice is to discuss aspects of the electronic cone penetrometer test that need to be considered when performing tests for environmental site
characterization purposes.
1.3 The electronic cone penetrometer test for environmental site characterization projects often requires steam cleaning the push rods and grouting the hole. There are
numerous ways of cleaning and grouting depending on the scope of the project, local regulations, and corporate preferences. It is beyond the scope of this practice to discuss all
of these methods in detail. A detailed explanation of grouting procedures is discussed in Guide D6001.
1.4 The electronic cone penetrometer may be be combined with other direct push sampling and testing methods. Estimated soil types can be conrmed by soil sampling (Guide
D6282). Cone penetrometer tests are often used to locate aquifers for installation of wells (Practice D5092, Guide D6274). Cone penetrometers can be equipped with additional
sensors for groundwater quality evaluations (Practice D6187). Location of other sensors must conform to requirements of Test Method D5778.
1.5 This practice is applicable only at sites where chemical (organic and inorganic) wastes are a concern and is not intended for use at radioactive or mixed (chemical and
radioactive) waste sites.
1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate
safety and health practices and determine the applicability of regulatory limitations prior to use.
1.8 Standard PracticeThis practice oers a set of instructions for performing one or more specic operations. This document cannot replace education or experience and should
be used in conjunction with professional judgment. Not all aspects of this practice may be applicable in all circumstances. This ASTM standard is not intended to represent or
replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without consideration of a project's
many unique aspects. The word "Standard" in the title means only that the document has been approved through the ASTM consensus process.
2. Referenced Documents (purchase separately)
ASTM Standards
C150 Specication for Portland Cement
D653 Terminology Relating to Soil, Rock, and Contained Fluids
D3740 Practice for Minimum Requirements for Agencies Engaged in Testing and/or Inspection of Soil and Rock as Used in Engineering Design and Construction
D5088 Practice for Decontamination of Field Equipment Used at Waste Sites
D5092 Practice for Design and Installation of Ground Water Monitoring Wells
D5778 Test Method for Electronic Friction Cone and Piezocone Penetration Testing of Soils
D6001 Guide for Direct-Push Ground Water Sampling for Environmental Site Characterization
D6187 Practice for Cone Penetrometer Technology Characterization of Petroleum Contaminated Sites with Nitrogen Laser-Induced Fluorescence
Recommended
Standards Tracker
Standards Subscriptions
Related Standards:
D6187
D5778
D6001
D6282
See All
All
GO
Home
Contact
About ASTM
Policies
Site Map
Cookies
Support
Copyright/Permissions
Copyright 1996 - 2016 ASTM. All Rights Reserved. ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA, 19428-2959 USA