ALC SDH Basics and Alcatel SDH System Training Presentation 46 Slide
ALC SDH Basics and Alcatel SDH System Training Presentation 46 Slide
ALC SDH Basics and Alcatel SDH System Training Presentation 46 Slide
-SDH Basics
-Alcatel SDH Systems
-Alcatel 1662SMC Introduction
-SDH Link No.17
SDH Basics
SDH Basics
STM- 4
STM- 16
STM- 64
STM-1
STM- 4
STM- 16
STM- 64
SDH
STM-1 MUX
STM- 4
SDH
STM- 16 MUX
SDH
STM- 64 MUX
STM-1
STM- 4
STM- 16
STM- 64
SDH
MUX
STM- 256
PLESIOCHRONOUS DIGITAL
HIERARCHY
SDH Basics
E1(2.047990 Mbps)
E2(8.447997 Mbps)
E3(34.367989Mbps)
E1(2.048001 Mbps)
E2(8.447989 Mbps)
E3(34.367998Mbps)
E1(2.047992 Mbps)
E1(2.048000 Mps)
PDH
MUX
E2(8.447991 Mbps)
E2(8.448000 Mbps)
PDH
MUX
E3(34.367990Mbps)
E3(34.368000Mbps)
E4(139.264000Mbps)
PDH
MUX
SDH Basics
Integrated Services:
SDH is the ideal platform for a wide range of services including POTS, ISDN,mobile radio, and data
communications (LAN, WAN, etc.). It is also able to handle more recent services such as video on demand
and digital video broadcasting via ATM.
Disadvantages of PDH
Changing from one hierarchical level to another
requires additional equipment.
For Add/drop of individual channels from the higher
order stream we have to disassemble / reassemble it
Redirection (cross-connection) of channels must be
done by hand on DDFs.
Administrative connections require separate
equipment to support Supervision, EOW and
protection switching.
Compatibility of transmission and administrative
signals between different vendor may give trouble.
SDH Basics
Note: The STM-0 is not widely used in the telecom network except for some Microwave
Links.
SDH Basics
STM-N
xN
AUG
x1
AU-4
VC4
C4
E-4(139.264Mbps)
Or
ATM(149.760Mbps)
C3
T-3(44.736Mbps)
Or
E-3(34.368Mbps)
Or
ATM(48.384Mbps)
x3
TUG-3
TU-3
VC3
x7
STM-0
AU-3
VC3
x1
TUG-2
Containers
Virtual Containers (Containers + POH)
Tributary Units/Administrative Units
(Virtual Containers + Pointers)
Tributary Unit Groups/Administrative Unit Groups
(Multiplexed structures of lower signals)
Alignment
Multiplexing
TU-2
VC2
C2
T-2(6.312Mbps)
Or
ATM(6.874Mbps)
TU-12
VC12
C12
E-1(2.048Mbps)
Or
ATM(2.144Mbps)
TU-11
VC11
C11
T-1(1.544Mbps)
Or
ATM(1.6Mbps)
x3
x4
K-TUG 3
L-TUG 2
M-TU 12
First KLM combination is 1 1 1
Last KLM combination is 3 7 3
Mapping of 63 E1s into STM1
E1 = 32 bytes/frame
C12 = 34 bytes/frame (E1 +2 stuffed bytes)
VC12 = 35 bytes/frame (C12 + 1 POH byte )
TU12 = 36 bytes/frame (VC12 +1 pointer byte)
M
So, one TU12 occupies 4 columns(36 bytes) in an STM1 frame
SDH Basics
1
1
270
RSOH
(3 x 9 Cells)
3
9 Rows 4
AU-4 POINTER
MSOH
(4 x 9 Cells)
SDH Basics
A1
A1
A2
A2
A2
J0
B1
E1
F1
D1
D2
D3
AU-4 Pointer
B2
B2
B2
K1
K2
D4
D5
D6
D7
D8
D9
D10
D11
D12
S1
X Bytes Reserved for national use.
* - Media Dependant Bytes
M1
E2
SDH Basics
Overhead Byte
Functions
A1,A2
Frame Alignment
B1,B2
D1,D2,D3
D4,..,D12
E1,E2
Voice Connections
F1
Maintenance
J0
Trace Identifier
K1,K2
S1
M1
1662SMC
1660SM
1642
Version 1(R1)
Version 2(R2)
Supports
Upto STM-4
Supports
Upto STM-16
Supports
Upto STM-1
Version 4(R4)
Supports
Upto STM-16
Version 5(R5)
Supports
Upto STM-64
Features
Shelf View
Technical Specifications
Compatible with existing plesiochronous systems as well as with the installed SDH networks,
Matrix capacity
96*96 stm-1 equivalent matrix(HO)
64*64 stm-1 equivalent matrix(LO)
Network interfaces: Stm-1/4/16
Customer interfaces: 2Mbps,34/45Mbps,140Mbps,ethernet,gigaethernet
26km
50km
49km
PONDICHERRY
CUDDALORE
TANJORE
TRICHY
54km
65km
CHIDAMBARAM
KUMBAKONAM
: 244 KMS
Fiber Owner
: BTSOL
: F no 43&44
: SDH LINK No 17
Shelf View:
ACCESS AREA-1
PORT AREA
ACCESSAREA-2
- Total Slots : 20
- Access Area 1: Slot 1-5 ( Hosts Access Cards like A63E1, A4S1, Congi ,etc).
- Access Area 2: Slot 16-20 ( Hosts Access Cards like A63E1, A4S1, Sergi ,etc).
- Port(Basic area)Area: Slot 6-15 (Hosts Port Cards like SYNTH, P4S1, P63E1, etc).
1. Congi card : It the used to control the whole SDH system. It consists
of power supply&house keeping unit. the congi card is in slot no1
2. Synth4Card: It is card used to insert the optical signals from the
fms.It consists the Optical module it is named as IL- 4.2,IL-1.2,IS1.1.- these are called Optical modules. There are two synth cards its
inserted in slot no 6&15.
3. P4S1N card: P indicates Port ,S1N indicates STM1. card
4. P63E1 card : P indicates port, 63 E1 indcates Electical signals.
5. A63E1-120 : its a card corresponding to P63E1 card.A indicates
access area.
6. LSPORT/HSPROT: Its is a Low Speed/High speed protection Card.
It is used to implement EPS protection.(i.e)it implements the
connection between the access and spare card.These cards receive
the signal coming from the access card via back panel.
SLOTS
P63E1N
7,8,9,10,11,12,13,14
P4ES1N
7,8,9,10,11,12,13,14
P3E3T3
7,8,9,10,11,12,13,14
SLOTS
P4ES1N
7,8,9,10,11,12,13,14
P4E4N
7,8,9,10,11,12,13,14
LEGEND:
(1) Channel #1 (N.B.)
(2) Channel #2 (N.B.)
(3) Bicolor LED:
Red led . local unit alarm
Green led . in service unit
ACRONYM
SLOTS
CONGI
1, 20
LEGEND:
(1) Power
(2) Housekeeping and remote alarm
(3) Rack lamp (not used in slot 20)
(4) QMD Q2 (not used in slot 20)
(5) I/O BNC Q3 10base2 (not used in slot 20)
(6) RJ45 Q3 10baseT (not used in slot 20)
(7) Bicolor LED:
Red led . local unit alarm
Green led . in service unit
Alcatel
1662 SMC Introduction
Commonly Used Cards ( continues..):
ACRONYM
SLOTS
SERGI
20
Sergi card Provides reduced combination of congi and service card functions
It has Power interface,Auxillary interface,I/p o/p clock interface for NE synchronization
LEGEND:
(1) Power
(2) Auxiliary channels:
2 channels G.703
2 channels RS232
2 channels V.11
(3) Aux and Sync. 2Mbit/s
J1 . 2MHz Input (T3) or 2Mbit/s Input (T6)
J2 . 2Mbit/s Input channel
J3 . 2MHz output (T4) or 2Mbit/s output (T5)
J4 . 2Mbit/s output channel
(4) Four wire telephone extersion point (RJ11)
(5) Z1-Z4 EOW zone selection LEDs (N.B.1)
(6) L1-L2 LEDs status for selective and multiple
call (N.B.2)
(7) Telephone jack
(8) Line seizure Key
(9) EOW zone selection Key
(10) Reset command Key
(11) Bicolor LED:
Red led . local unit alarm
Green led . in service unit
SYNTH16
6,15
SYNTH16 can be EPS 1+1 Protected
Slot no:6 is main card
Slot no:15 is spare card
Synth16 card is equipped with two parts for modules
1*STM-16 signals can be processed by the SYNTH 16 card
Synth 16 card performs several fns like shelf controller,Equip controller,
Performance monitoring collection,remote inventory
Synth 16 cards have a 96*96 stm-1 Matrix capacity.
It is also called as Compact ADM16 Card
LEGEND
(1) Reset command key
(2) Channel #1 (N.B.)
(3) Lamp test pushbutton
(4) Personal Computer Connector (F interface)
(5) Red LED . Urgent Alarm (Critical or Major)
(6) Red LED . Not Urgent Alarm (Minor)
(7) Yellow LED . Alarm storing (Attended)
(8) Yellow LED . Abnormal condition
(9) Yellow LED . Indicative Alarm (Warning)
(10) Green LED . when on it means active unit
when off it means standby unit
(11) Bicolor LED:
Red led . local unit alarm (INT)
Green led . in service unit
(12) Alarm storing pushbutton (Attended)
SLOTS
SLOTS
A63E1B (120Ohm)
2,3,4,5,16,17,18,19
SLOTS
A2S1
2,3,4,5,16,17,18,19
A2S1 is the access card for the P4S1N and P4E4N port cards.
A2S1 can host upto 2modules(optical stm-1) in the front panel.
LEGEND
(1) Channel #3 (N.B.)
(2) Channel #4 (N.B.)
(3) Bicolor LED:
Red led . local unit alarm
Green led . in service unit
SLOTS
A3E3
2,3,4,5,16,17,18,19
A3T3
2,3,4,5,16,17,18,19
LEGEND
(1) Channel #1
(2) Channel #2
(3) Channel #3
(4) Bicolor LED:
Red led . local unit alarm
Green led . in service unit
SLOTS
A4ES1
2,3,4,5,16,17,18,19
LEGENDA
(1) Channel #1
(2) Channel #2
(3) Channel #3
(4) Channel #4
(5) Bicolor LED:
Red led . local unit alarm
Green led . in service unit
EQUIPED
ON PORTS
S-1.1
P4S1N,P4ES1
ATM4X4,A2S1
SYNTH4
L-1.1
L-1.2
S-1.1
S-Stands for short haul
1-stands for stm-1
1-stands for representing 1310nm
L-1.1
L-Stands for Long haul
1-stands for stm-1
1-stands for representing 1310nm
Module types:
Stm-1 and stm-4 Optical module:SC-PC Type and Fc-Pc Type are available
Stm-1 & stm-4 Optical modules are available and it physically different
140Mbit/s-STM-1 Electrical module.
LEGENDA
(1) Multicolor LED:
Red led . local unit alarm
Orange led . temperature major than 55 C
Green led . in service unit
(2) Battery A connector
(3) Battery B connector
(4) Alarms connector for 1662SMC on the Left side of the Rack
(5) Not used
(6) Alarms connector for 1662SMC on the Right side of the Rack (6)
HWF
+ VBATT (male)
GND (female)
POWER
-VBATT (male)
The optical interfaces which have HAZARD LEVEL 3A (see Table A below ) carry the following hazard symbol
label:
Caution : Invisible Laser Radiation may be present inside the optical interfaces carrying the above label ,hence
NEVER directly view into the beam.Doing so may result in the permanent damage to the eyesight.
UNIT/PORT
OPTICAL INTERFACE
HAZARD LEVEL
STM.1
STM.1
3A
STM.1
3A
STM.4
STM.4
3A
STM.4
3A
STM.16
3A
STM.16
3A
STM.16
3A
CLASSIFICATION OF ALARMS
LCT access through Q interface for NMS access through the LAN card
Tools: Power source, power meter, OTDR (Optical Time Domain Reflectometer)
and OSA (Optical Spectrum Analyser)
Charaterisitics
P63E1
Bit rate
No. of channels
63
Line Code
HDB3
Signal amplitude
2.37 Vp on 75 Ohm
unbalance/ 3 Vp on 120
Ohm balance.
Bit Rate
No. of tributaries
Line Code
HDB3
Signal amplitude
1Vp/75ohms
Bit rate
No. of tributaries
Line Code
B3ZS
Bit rate
Line Code
CMI
Bit rate
Line Code
CMI
P3E3
P3T3
P4S1E
P4E4
STM-1
S 1.1
L 1.1
L 1.2
-15 to -8dB
0 to - 5dB
0 to 5dB
Receiver
Sensitivity
-28dB
-37dB
-37dB
Receiver Overload
-8dB
-10dB
-10dB
L 4.1
L 4.2
-15 to -8dB
2 to -3dB
2 to 3dB
Receiver
Sensitivity
-28dB
-28dB
-28dB
Receiver Overload
-8dB
-8dB
-8dB
L 16.1
L 16.2
0 to -5dB
2 to -2dB
2 to 2dB
-18dB
-27dB
-28dB
0dB
-8dB
-8dB
Trans Power
S 4.1
S 16.1
PROTECTION TYPES
EPS
Equipment
Protection
Switching
1:1
1:N
MSP
Multiplex
Section
Protection
MSP-LINEAR
MS-SP RING
SNCP/N
SNCP/I
EQUIPMENT 2
1.The 1+1 EPS Protection type means that one working equip is Protected by One Redundant Equip
2.The mode of 1+1 EPS Protection is Non Revertive.
EQUIPMENT 1
LINE 2
EQUIPMENT 1
LINE N
EQUIPMENT N
EQUIPMENT P
1)1:N Type protection means that N working Pieces of equip are protected
by just 1 Portecting Equivalent.
2)The mode of 1:N Eps protection is revertive.
1+1Protection
TX
PROTECTION
TX
LOW PRIORITY LINE WORKING
TX
TX
1:1Protection
RX
RX
WORKING
WORKING
TX
RX
PROTECTION
RX
RX
1:N Protection