0% found this document useful (0 votes)
134 views

Tutorial Synch Generator

1) The generator has a voltage of 2200V, armature resistance of 0.5Ω, and synchronous reactance of 4.97Ω. 2) At unity power factor, the voltage regulation is 4.72% with an output voltage of 2304V. 3) At 0.8 leading power factor, the voltage regulation is -9.7% with an output voltage of 1988V. 4) At 0.8 lagging power factor, the voltage regulation is 16.6% with an output voltage of 2565V.

Uploaded by

Eyad A. Feilat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
134 views

Tutorial Synch Generator

1) The generator has a voltage of 2200V, armature resistance of 0.5Ω, and synchronous reactance of 4.97Ω. 2) At unity power factor, the voltage regulation is 4.72% with an output voltage of 2304V. 3) At 0.8 leading power factor, the voltage regulation is -9.7% with an output voltage of 1988V. 4) At 0.8 lagging power factor, the voltage regulation is 16.6% with an output voltage of 2565V.

Uploaded by

Eyad A. Feilat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Problem 5

From the following test results, determine the voltage regulation of a 2000 V, singlephase synchronous generator delivering a current of 100 A at (i) unity pf, (ii) 0,8 leading
pf and (iii) 0,8 lagging pf. The result :
Full-load current 100 A is produced on short circuit by a field excitation 2,5 A.
An emf 500 V is produced on open-circuit by the same excitation.
Armature resistance is 0,8 , and draw it phasor diagram.
Solution
Single-phase generator
V = 2200 V, Ra = 0.5 , I = 100 A

500 V

ISC
I = 100 A

If

3A
Synchronous impedance
Zs

E1 (occ )
= 500 / 100 = 5
I 1 ( scc )

Synchronous reactance
Zs2 = Ra2 + Xs2
or

X s Z s Ra

Diagram phasor

5 2 (0.5) 2 24.75 = 4.97

General form of voltage equation is

E (V cos IRa ) 2 (V sin IX s ) 2

1/ 2

positive sign for inductive load


negative sign for capacitive load
i) Unity power factor
cos = 1 ,

sin = 0

I Ra = 100 x 0.5 = 50 V
I Xs = 100 x 4.97 = 497 V

E (V cos IRa ) 2 ( IX s ) 2

1/ 2

E = [(2200 + 50)2 + 4972]1/2


E=

5309509 = 2304 V

%VR

E V
2304 2200
x100% =
x100%
V
2200

%VR = 4.72 %
ii) Pf 0.8 lead
cos = 0.8 , = 36.87o , sin = 0.6

E (V cos IRa ) 2 (V sin IX s ) 2

1/ 2

E = [(2200x0.8 + 50)2 + (2200x0.6 497)2]1/2


E = [(1760 + 50)2 + (1320 497)2]1/2
E = [(1810)2 + (823)2]1/2 = (3953429)1/2 = 1988 V

%VR

E V
1988 2200
x100% =
x100%
V
2200

%VR = - 9.7 %
iii) Pf 0.8 lag
cos = 0.8, sin = 0.6

E (V cos IRa ) 2 (V sin IX s ) 2

1/ 2

E = [(2200x0.8 + 50)2 + (2200x0.6 + 497)2]1/2


E = [(1760 + 50)2 + (1320 + 497)2]1/2
E = [(1810)2 + (1817)2]1/2 = (6577589)1/2 = 2565 V

%VR

E V
2565 2200
x100% =
x100%
V
2200

%VR = 16.6 %

Problem 6

A 3-phase, 800 kVA, 11 kV, star connected synchronous generator has resistance of 1,5
/phase and synchronizing reactance of 25 /phase. Find the percentage regulation for
a load of 600kW at 0,8 leading power factor.
Solution
3 phase generator
S = 800 kVA = 800,000 VA
VLL = 11 kV = 11,000 V
Ra = 1.5 , Xs = 25
Voltage/phase = 11000 /
3 x VLL x I

S=
or

3 = 6350 V

3V LL

800000
3 x11000

= 42 A

I Ra = 42 x 1.5 = 63 V
I Xs = 42 x 25 = 1050 V
Pf 0.8 lead
cos = 0.8 , = 36.87o , sin = 0.6

E (V cos IRa ) 2 (V sin IX s ) 2

1/ 2

E = [(6350x0.8 + 63)2 + (6350x0.6 1050)2]1/2


E = [(5080 + 63)2 + (3810 1050)2]1/2
E = [(5143)2 + (2760)2]1/2 = (34068049)1/2 = 5837 V
%VR

E V
5837 6350
x100% =
x100%
V
6350

%VR = - 8 %

You might also like