June 2009
June 2009
tSN
06CS~
IIIIIIIIIII
Fifth Semester B.E. Degree Examination, June-July. 20.~
Design of Structures RCC
Max. Marks:lOO
Time: 3 hrs.
Note: 1. Answer any FIVE full questions selecting at least TWO from each part
2. Use ofIS456-2000, SP-16, JS 875 permitted. Use SP-16 for Question 6 only.
3. Assume any missing data suitably.
PART-A
a Explain the terms balanced, under reinforced and over reinforced sections.
(06 Marks)
b. A.R.C. beam of section 300 mm x 550 mm (over all) is reinforced with 4 bars of 16 mm
with an effective cover of 50 mm. The beam is simply supported over an effective span of
5m. Find the maximum load carrying capacity of the beam inclusive of its self-weight. M20
concrete and Fe500 steel are used.
(14 Marks)
(20 Marks)
A reinforced concrete beam of size 250 x 500 mm (over all) is provided with 4 bars of 20
mm at an effective cover of 40 mm. The section has to resist a BM of 60 kN-m. Determine
the crack width at the mid point of the tension edge. M20 concrete and Fe 415 steel are used.
(20 Marks)
The bars are arranged in one layer with side covers of 25 mm, clear.
a.
Discuss the design situations, which neeo the provision of doubly reinforced beams.
(06 Marks)
b. Determine the ultimate moment of resistance of a doubly reinforced beam with b = 300 mm,
D = 600 mm Ast = 6 bars of 20 mm, Ase = 6 bars of 16 mm effective cover = 50 mm for
(14 Marks)
both steels. M25 concrete and Fe 415 steel are used.
PART-B
Design. a R.C. slab for a room of clear size 4 m x 5 m. The slab is supported on walls of 300
mm thickness with two adjacent edges continuous and other two edges discontinuous. Live
load is 3 kN/m2 . Assume floor finish as 0.6 kN/m2 and ceiling finish as 0.4 kN/m2 . Use M20
concrete and Fe 415 steel. Sketch the reinforcement details.
(20 Marks)
6 . a. Design a column 4 m long restrained in position and direction at both ends to carry an axial
(10 Marks)
load of 1600 kN. Use M20 concrete and Fe 415 steel.
b. A column of size 300 mm x 400 mm has an effective length of 3.6 m and is subjected to
Pu= 1100 kN and Mu = 150 kN-m about its major axis. Design the column using M25
(10 Marks)
concrete and Fe 415 steel. Provide the steel on four sides.
Design a square footing of uniform depth for a short axially loaded column of size 300 mm
x 300 mm. The column carries an axial service load of 600 kN in compression. SBC of
2
foundation soil is 180 kN/m . Use M20 concrete and Fe 415 steel. Sketch the details of
reinforcement.
(20 Marks)
Design a dog-legged stairs for an office building in a room of clear size of 2.8 m x 5.8 rn.
The vertical distance between the floors is 3 .6 m, width of each flight is 1.25m. Take a live
load of 3 kN/m2 . The stairs are so provided that the landing slabs are supported on 230 mm
wide beams at their outer edges, leading to a structural arrangement of landing slab spanning
in the direction of going. Use M20 concrete and Fe 415 steel. Sketch the reinforcement
(20 Marks)
details.
*****