0% found this document useful (0 votes)
389 views32 pages

Mass Comparators

This document discusses precision mass metrology equipment developed by Sartorius in cooperation with various metrology institutes. It summarizes key products including a 1 kg prototype mass comparator capable of measuring mass differences of 0.1 μg under vacuum conditions. The document highlights development of automatic mass comparators and robots that can determine mass from 1 mg to 50 kg through fully automated comparisons. It provides technical specifications for the 1 kg prototype comparator and acknowledges partners that helped develop precision metrology equipment.

Uploaded by

purwanto
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
389 views32 pages

Mass Comparators

This document discusses precision mass metrology equipment developed by Sartorius in cooperation with various metrology institutes. It summarizes key products including a 1 kg prototype mass comparator capable of measuring mass differences of 0.1 μg under vacuum conditions. The document highlights development of automatic mass comparators and robots that can determine mass from 1 mg to 50 kg through fully automated comparisons. It provides technical specifications for the 1 kg prototype comparator and acknowledges partners that helped develop precision metrology equipment.

Uploaded by

purwanto
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 32

Mass Metrology

Precision Is a Matter of Having


the Right Equipment

turning science into solutions

Precision Beyond Compare


International trade requires standardized
weights and measures worldwide. Mass
plays an essential role here, as the major
part of world trade is conducted on the
basis of mass. To ensure that measurements
of mass are made on the same basis
throughout the world, each country has
a National Metrology Institute (NMI) that
compares and traces all units to guarantee
their consistent accuracy. These National
Metrology Institutes (NMIs) represent the
authority in all matters relating to physical
units of measure and national standards
they are the measure of all things.
For and in cooperation with NMIs and the
BIPM, Sartorius, a global expert in metrology, develops innovative mass comparators
of the very highest quality alongside other
groundbreaking products and systems.
In the last years alone, the following
products have been introduced in
cooperation with metrology institutes:
A variety of robot systems

At this point, we would like to specially


thank our all our partners for their outstanding cooperation in helping to make
our developments exceptionally successful.
For instance, together with the four partners listed below, we developed the most
accurate balance in the world, the CCL1007
mass comparator:
The Bureau International de Poids et
Mesures (BIPM)
The German Physikalisch-Technische
Bundesanstalt (PTB)
SIOS Messtechnik GmbH
The Technical University of Ilmenau (TUI),
Germany
With the support of the next two partners
in Austria, we developed a number of robot
systems and an innovative and fully automatic system for density determination:
The Austrian Bundesamt fr Eichund Vermessungswesen (BEV, The Federal
Office of Metrology and Surveying)

Fully automatic systems for determining


the volume of weights

The Technical University of Vienna

1 kg prototype mass comparator


with an incredibly high resolution
of 0.0000001 g

In cooperation with our two partners


below, we deleveloped a robot system
along with sophisticated metrological
software:

And many more products at the forefront


of technology

Hfner Gewichte GmbH


MARO Electronics

Products for the Determination of Mass


Page
Automatic Mass Comparators and Robots
Determination of Mass to the Very Highest Standards
From the 1 kg Prototype to Mass Standards
Robot for Fully Automated Determination of Mass from 1 mg to 50 kg
Custom-built, Fully Automatic Robot Solutions
Automatic Mass Comparators with Load Alternator

4
5
6
7
8

Manual Mass Comparators


Up to 1 kg
Up to 20 kg
Up to 300 kg
Up to 3000 kg

10
11
12
13

Summary and Product Recommendations


Application Range of Mass Comparators in Accordance with OIML R111
Application Range of Mass Comparators in Accordance with ASTM E617
Selection of Comparators for Equipping a Mass Laboratory

14
15
16

Accessories
Susceptometer A Complete Solution for Testing the Magnetic Properties
of Weights
Volume and Density Determination up to 1 kg
Density Determination up to 50 kg using the YP50K Pycnometer
Software for Mass Metrology One Software
Program for All Equipment ScalesNet32
Software for the Comparison of Mass YPR02C
Accessories for Mass Metrology

20
21
22

Technical Specifications
1 kg Prototype Mass Comparator and Robot
Mass Comparators with Load Alternator
Mass Comparators up to 1 kg
Mass Comparators from 1 kg to 10 kg
Mass Comparators from 10 kg to 60 kg
Mass Comparators from 60 kg to 300 kg
Mass Comparators from 600 kg to 3000 kg
Determination of Volume, Density, Susceptibility and Magnetism

24
25
26
27
28
29
30
31

17
18
19

Automatic Mass Comparators and Robots


Determination of Mass to the Very Highest Standards
Sartorius masters the core disciplines of
weighing like no other and sets new
standards in mass metrology. In cooperation with the Bureau International des
Poids et Mesures* and the Institute for
Process Measurement and Sensor Technology of the Technical University of Ilmenau,
Sartorius has developed a mass comparator
the CCL1007 that is capable of determining differences in mass to an accuracy
of 0.1 g for weights of 1 kg even under
high-vacuum conditions.
The mass comparator is protected from
environmental effects by a pressure-stable
aluminum chamber. In the vacuum chamber, measurements can be performed at
high vacuum up to 10-6 bar. Unlike conventional stainless steel vacuum bell jars,
the aluminum chamber does not cause any
magnetic reactions that would affect the
weighing system.

The unique three-point holder is capable


of handling both cylindrical weights and
silicon spheres efficiently.
The equipment thus meets all of the
requirements for the new definition of
the kilogram using a silicon sphere.
The scientific tests necessary to determine
the Avogadro constant can therefore be
performed conveniently and precisely.
The weigh cell is located in the upper
section of the vacuum chamber. The
weighing pan for the substitution weights
is accessed via the upper loading hatch.

All components inside the vacuum chamber


are completely resistant to high vacuum
and, therefore, will not outgas under vacuum. This prevents any contamination of the
weights. All materials used in the vacuum
chamber are solid materials with a low
vapor pressure. They are free of oil and
grease and thus ideally suited to
high-vacuum applications.

The motors that drive the load alternator


and the weight changing device are located
outside the vacuum chamber. This reduces
interference caused by temperature
fluctuations.

The more than 20 vacuum flanges enable


additional sensors to be introduced into
the vacuum chamber, which has sufficient
space to accommodate additional
measuring instruments.

Test objects and reference weights can


be introduced easily and positioned
precisely through the lower loading hatch
by means of an automatic loading device,
without the need to open the entire
vacuum chamber. The load alternator can
accommodate up to eight weights. The
position of the weight on the load alternator is assigned at the operating terminal.
The quantity and method of mass comparisons are also entered at this terminal.
After the weight has been transferred into
the interior of the vacuum chamber, a
three-point lifting mechanism picks up this
weight. This lifting mechanism determines
the center of mass of the weight fully
automatically and centers the weight on
the load alternator.

* International Bureau of Weights and


Measures (BIPM)
The vacuum chamber of the CCL1007

The driving force of these motors is transferred into the interior of the vacuum
chamber by rotary axes and vacuum couplings. The load alternator is driven by a
pulley hoist system.

From the 1 kg Prototype to Mass Standards


Areas of Application
Use as a 1 kg prototype weighing system
for the subdivision of the mass of the
primary reference standards of National
Metrology Institutes (NMIs) with national
mass reference standards (kilogram
prototype)
Dissemination of the mass scale of NMIs
in the range of 1 kg to 1 mg; adapter
plates are required for groups of weights
and weights < 200 g
Determination of mass for international
comparison measurements (key comparisons) and calibrations for national
institutes, calibration laboratories and
industry in accordance with the attainable measurement uncertainties specified
in the CMC tables published by the BIPM
The load alternator of the CCL1007

Experimental determination of air density


by comparison weighing of special
buoyancy artifacts in air and under
vacuum
Determination of the mass of 1 kg silicon
spheres (also suitable within the scope of
the Avogadro project for more accurate
definition of the Avogadro constants and
for new definition of the kilogram mass
unit)
Experimental research on the impact of
cleaning procedures as well as on the
effects that sorption and convection
could have on mass and on the long-term
stability of mass standards

Technical Specifications

CCL1007

Maximum capacity

1031 g

Readability

0.1 g

Repeatability, s*

s < 0.2 g

Repeatability in vacuum, s*

s < 0.1 g

Repeatability (typical), s*

s < 0.1 g

Linearity

< 1 g

Electronic weighing range

2g

Pressure range

10-6 1000 mbar

Application ranges:
OIML R111 classes
with adapter plates for groups of weights
Silicon sphere

< E1 1 kg
< E1 1 mg 1 kg
95 mm d

s* The standard deviation "s" is the repeatability calculated from 6 ABBA cycles after elimination of drift. Prerequisites for accurate calculation of the standard deviation are
good ambient conditions in accordance with OIML R111 for an E1 mass standards laboratory.

Robot for Fully Automated determination of Mass


from 1 mg to 50 kg
Robot systems with latest weighing technology guarantee highest accuracy for the
mass determination.
The fully automated mass comparison
simplifies work in the mass laboratory. This
enables complete sets of weights to be
measured efficiently within the shortest
time possible.
Comb-type weight grabber with 4 weights

Reference and test weights are positioned


in the magazine that accommodates
a high number of weights. The weighing
mode is entered on the PC, the number of
comparison cycles is defined and a direct
1:1 mass comparison or subdivision (dissemination of mass for class E1 weights) is
initiated. The robot retrieves the weights
from the magazine and starts mass comparison. Prior to mass comparison, the
robot automatically combines the groups
of weights required for dissemination of
mass according to the weighing design.

Close-up of the CCR10-1000 magazine

The comb-type weight grabbers are


designed so that any desired types of
weight wire or leaf weights or knob,
cylindrical or disk weights can be handled
efficiently.
The number of magazine positions is
specified by the customer. Up to
164 magazine positions can be provided
for the range of 1 mg to 1 kg.
The robot systems are supplied with
a PC and user-friendly control software.
Naturally, all Sartorius robot systems can
be controlled directly by ScalesNet 32 (see
YSN01C on pages 20-21). This is a software
program designed to cover all requirements
and to network all equipment in the mass
standards laboratory.

For efficient operation of the robot,


the reference weight and test weight are
placed on separate comb-type weight
grabbers. These weight grabbers accommodate a group of up to four weights. Groups
of weights are placed on the weighing pan
simultaneously, guaranteeing fast loading
of the mass comparator with reference and
test weights.

Detail of the magazine for CCR10-1000

Robot systems, CCR10-1000, for determining the


mass of weights (1 mg 1 kg)

Custom-built, Fully Automatic Robot Solutions


Two Sartorius robot systems cover the
entire application range for calibrating E1
weights from 1 mg to 50 kg, in accordance
with OIML R111. Each robot system
operates up to two weigh cells in perfect
synchrony.
This concept makes it possible for complete
sets of class E1 weights from 1 mg to 1 kg
or from 1 kg to 50 kg to be disseminated
from a single 1 kg mass standard with no
need to insert the weights into different
robot systems. The robot independently
combines the required groups of up to 4
weights.
Sartorius robot systems are customized to
meet individual requirements, and systems
can be equipped with one or two weigh
cells. The number of magazine positions is
variable.

Technical Specifications
CCR10

Detailed view of the CCR20K robot system

CCR10-1000
CCR1000

CCR10K-20K
CCR10K-50K
CCR20K
CCR10K
CCR50K

Application range (E1)

1 mg 10 g

10 g 1 kg

10 kg | 20 kg

1|2|3|5|6|10 kg

20 kg|50 kg

Maximum capacity

10.5 g

1002 g

20.05 kg

10.05 kg

51 kg

Readability

0.1 g

1 g

0.1 mg

10 g

1 mg

Repeatability, s*

< 0.3 g

< 0.3 mg

< 50 g

< 3 mg

Repeatability (typical), s*

< 0.2 g

0-100 g : < 3 g
< 8 g
< 2 g

< 0.1 mg

< 30 g

< 1 mg

Linearity

1 g

20 g

3 mg

0.3 mg

50 mg

Electronic weighing range

3.5 g

2.1 g

60 g

60 g

51 kg

Magazine positions

39

21

10

2-39

2-10

2-10

2-10

Optional magazine positions 26-65

CCR20K robot system


s* The standard deviation "s" is the repeatability calculated from 6 ABBA cycles after elimination of drift. Prerequisites for accurate calculation of the standard deviation are
good ambient conditions in accordance with OIML R111 for an E1 mass standards laboratory.

Automatic Mass Comparators with Load Alternator


Automated weight handling provides the
best repeatability.
Sartorius mass comparators with a load
alternator perform fully automatic mass
comparison of individual reference mass
standards and groups of weights in any
combination. As no additional cylindrical
or stackable weights are required, loss of
accuracy is prevented.
Relatively large objects, such as disk
weights, buoyancy artifacts and pressure
disks, can also be easily positioned for
determination of their mass.

Comparison of mass standards as groups of weights using the CC1000S-L

To determine air density, we recommend


our climate measurement station
YCM02C|YCM03C (see page 22) along with
the associated software.
The ScalesNet32 software enables all
mass and volume comparators, automatic
systems and climate measurement
stations in a mass laboratory to be networked together. The software is designed
for data acquisition, automatic equipment
control, data evaluation and storage, and
generation of calibration certificates.
ScalesNet32 covers all international
requirements placed on a professional mass
laboratory (see pages 2021).

Subdivision weighing on CC10000S-L|CC10000U-L|CC20000S-L

Comparison of a weight with a group of mass standards using the CC50001S-L

Mass comparators with a load alternator


are ideally suited for determining the mass
of class E1 weights.

The integrated centering equipment is


positioned below the weighing pan to give
the user the best possible access.

The generously sized weighing pan provides sufficient space for the calibration
of groups of weights and large-diameter
weights.

These mass comparators can also be used


as stand-alone instruments without a PC.
Networking and PC control are possible
by using external programs.

CC1000S-L
Maximum capacity:
Electronic weighing range:
Readability:
Repeatability (typical), s*:

CC10000U-L
Maximum capacity:
Electronic weighing range:
Readability:
Repeatability (typical), s*:

10.05 kg
60 g
0.01 mg
0.02 mg

CC10000S-L
Maximum capacity:
Electronic weighing range:
Readability:
Repeatability (typical), s*:

10.05 kg
60 g
0.1 mg
0.05 mg

CC20000S-L
Maximum capacity:
Electronic weighing range:
Readability:
Repeatability (typical), s*:

20.05 kg
60 g
0.1 mg
0.1 mg

1.002 kg
2g
0.001 mg
0.001 mg

CC50001S-L
Maximum capacity:
Electronic weighing range:
Readability:
Repeatability (typical), s*:

51 kg
51 kg
1 mg
2 mg

s* The standard deviation "s" is the repeatability calculated from 6 ABBA cycles after elimination of drift. Prerequisites for accurate calculation
of the standard deviation are good ambient conditions in accordance with OIML R111 for an E1 mass standards laboratory.

Manual Mass Comparators up to 1kg


The new CCE generation of manuallyoperated weighing equipment is the
ultimate in manual mass comparators.
With up to 61 million weighing steps, these
instruments are world class. The monolithic
weigh cells that are manufactured
as a single structure from a high-quality
aluminum alloy deliver results with
outstanding repeatability.

All manual CCE comparators have a fully


electronic weighing range or several
overlapping weighing ranges. As a result,
any weight value between 0 g and the
maximum capacity can be attained.

Below-balance weighing equipment in


Sartorius mass comparators makes density
determination easy. This equipment is
standard on nearly all mass comparators in
this product range.

The CCE products have an electronic


draft shield and below-balance weighing
equipment.

In addition to the below-balance weighing


equipment, Sartorius mass comparators are
also available with the YDK01 density
determination kit.

31 g
1 g
1 g

CCE66
Maximum capacity and
electronic weighing range:
Readability:
Repeatability (typical), s*:

61 g
1 g
1 g

505 g
210 g
10 g
15 g

CCE1005
Maximum capacity:
Electronic weighing range:
Readability:
Repeatability (typical), s*:

1105 g
605 g
10 g
20 g

Reliability and speed are key features of


this new class of mass comparators.

CCE6
Maximum capacity and
electronic weighing range:
Readability:
Repeatability (typical), s*:

6.1 g
0.1 g
0.2 g

CCE36
Maximum capacity and
electronic weighing range:
Readability:
Repeatability (typical), s*:

CC111
Maximum capacity:
Electronic weighing range:
Readability:
Repeatability (typical), s*:

111 g
21 g
1 g
2 g

CC500
Maximum capacity:
Electronic weighing range:
Readability:
Repeatability (typical), s*:

s* The standard deviation "s" is the repeatability calculated from 6 ABA cycles after elimination of drift. Prerequisites for accurate calculation
of the standard deviation are good ambient conditions in accordance with OIML R111 for an E1 mass standards laboratory.

10

Manual Mass Comparators up to 20 kg


Developed for mass metrology, the integrated application software facilitates daily
work routines. This software guides the
user, while mass comparator takes over the
timing and, at the end of the ABA or ABBA
cycles, delivers the difference in mass, standard deviation and individual values.
All CCE mass comparators up to a load
range of 5 kg have a built-in motorized
calibration and adjustment weight.

The majority of Sartorius manual mass


comparators are designed so that they do
not require space-consuming centering
equipment within the weighing chamber.
The complete electronics and the power
supply for display and evaluation are
separate from the weighing system in
order to prevent heat from affecting
the results.

1.2 kg
0.1 mg
0.05 mg

CC10000S
Maximum capacity:
Electronic weighing range:
Readability:
Repeatability (typical), s*:

10.05 kg
60 g
0.1 mg
0.1 mg

CCE2004
Maximum capacity and
electronic weighing range:
Readability:
Repeatability (typical), s*:

2.5 kg
0.1 mg
0.1 mg

CC20000
Maximum capacity:
Electronic weighing range:
Readability:
Repeatability (typical), s*:

20.05 kg
60 g
1 mg
1 mg

CCE5003
Maximum capacity and
electronic weighing range:
Readability:
Repeatability (typical), s*:

5.1 kg
1 mg
0.5 mg

CCE5004
Maximum capacity and
electronic weighing range:
Readability:
Repeatability (typical), s*:

5.1 kg
0.2 mg
0.3 mg

CCE1004
Maximum capacity and
electronic weighing range:
Readability:
Repeatability (typical), s*:

Additional draft shields are available for


nearly all models. They reduce air
movement caused by air conditioning
systems and, in this way, enable excellent
repeatability to be achieved even under
unfavorable ambient conditions (for a list,
see page 23).

CCE10K3
Maximum capacity and
electronic weighing range:
Readability:
Repeatability (typical), s*:

10.1 kg
1 mg
1 mg

s* The standard deviation "s" is the repeatability calculated from 6 ABA cycles after elimination of drift. Prerequisites for accurate calculation of the standard deviation are
good ambient conditions in accordance with OIML R111 for an E1 mass standards laboratory.

11

Manual Mass Comparators up to 300 kg


All mass comparators from a load range
of 40 kg have a continuous, full-resolution
weighing range and large weighing pan.
This makes them ideal for universal use.
If necessary for below-balance weighing, a
hanger can be attached directly to the port
on the weigh cell. In this way, for example,
a simple, yet highly accurate, density measurement setup can be achieved. The integrated software supplied for density determination on all CCE models simplifies work
routines.

The single-point monolithic weigh cell


based on electromagnetic force compensation supports over 60 kg. As a result of
the direct introduction of force into the
weigh cell, unprecedented repeatabilities
of just a few milligrams are achieved with
this weighing system. Due to the direct
introduction of force, the off-center loading error (eccentricity) is extremely low,
and the stated specifications are also
achieved without the use of a Centermatic.

CCE40K3
Maximum capacity:
Readability:
Repeatability (typical), s*:

41 kg
2 mg
3 mg

CC64K
Maximum capacity:
Readability:
Repeatability (typical), s*:

64 kg
50 mg
100 mg

CCE60K2
Maximum capacity:
Readability:
Repeatability (typical), s*:

64 kg
10 mg
7 mg

CC150K
Maximum capacity:
Readability:
Repeatability (typical), s*:

151 kg
100 mg
200 mg

CCE60K3
Maximum capacity:
Readability:
Repeatability (typical), s*:

64 kg
2 mg
4 mg

CC300K
Maximum capacity:
Readability:
Repeatability (typical), s*:

303 kg
1000 mg
500 mg

Depending on the ambient conditions, the


excellent repeatabilities can be increased
still further by using a Centermatic and a
draft shield.

s* The standard deviation "s" is the repeatability calculated from 6 ABA cycles after elimination of drift. Prerequisites for accurate calculation of the standard deviation are
good ambient conditions in accordance with OIML R111 for an E1 mass standards laboratory.

12

Manual Mass Comparators up to 3000 kg


All Sartorius heavy-duty mass comparators
are made of high quality stainless steel.
This design eliminates the possibility of
magnetic reactions from magnetic weights
having an effect on comparison weighing.

Models of the CCS range are equipped


with four high-resolution strain-gauge
type load cells which are aligned with
one other. Draft shields are available
for all high-capacity mass comparators
(see page 23).

The unique sandwich construction


with integrated, strain-free weigh
cells guarantees excellent repeatabilities
even when weights are loaded in a
"heavy-handed" way.

CCT1000K
Maximum capacity:
Readability:
Repeatability (typical), s*:
Dimensions in cm,
W+D+H:
CCT2000K
Maximum capacity:
Readability:
Repeatability (typical), s*:
Dimension in cm,
W+D+H:

1200 kg
1g
2g
151+131+30

2010 kg
1g
5g
192+166+30

CCS600K
Maximum capacity:
Readability:
Repeatability (typical), s*:
Dimensions in cm,
W+D+H:
CCS1000K
Maximum capacity:
Readability:
Repeatability (typical), s*:
Dimensions in cm,
W+D+H:
CCS3000K
Maximum capacity:
Readability:
Repeatability (typical), s*:
Dimensions in cm,
W+D+H:

The innovative sturdy three-point frame of


the CCT models with three high-resolution
strain-gauge type load cells guarantees a
stable and distortion-free setup. Potential
off-center loading errors are minimized
due to the large distances between the
weigh cells.

605 kg
1g
2g
80+100+30

1510 kg
5g
5g
80+100+30

3010 kg
10 g
12 g
150+125+30

s* The standard deviation "s" is the repeatability calculated from 6 ABA cycles after elimination of drift. Prerequisites for accurate calculation of the standard deviation are
good ambient conditions in accordance with OIML R111 for an E1 mass standards laboratory.

13

Robots and automatic mass comparators

Summary and Product Recommendations


Application Range of Mass Comparators in Accordance with OIML R111
CCL1007

E1

CCR10-1000

E2

CCR10

F1

CCR1000
CCR10K-20K
CCR10K-50K
CCR10K
CCR20K
CCR50K
CC1000S-L
CC10000U-L
CC10000S-L
CC20000S-L
CC50001S-L
CCE6

E1

CCE36

E2

CCE66

F1

CC111

F2

CC500

M1

CCE1005
CCE1004
Manual mass comparators

CCE2004
CCE5004
CCE5003
CC10000S
CCE10K3
CC20000
CCE40K3
CCE60K3
CCE60K2

F1

CC64K

F2

CC150K

M1

CC300K

M2

CCS600K
CCT1000K
CCS1000K
CCT2000K

mg

5000

2000

500

1000

200

50

100

20

10

500

200

50

100

20

10

500

200

50

100

20

10

CCS3000K
Mass

kg

The chart shows the suitability of mass comparators for the OIML R111 accuracy classes.

The results shown in the bar chart were


obtained by performing at least 3 ABBA
cycles with automatic comparators and 3
ABA cycles with manual comparators.

The diagram shows the suitability of


comparators at a confidence level of 95%
(K=2) for the application ranges.
The stated application ranges can be
extended to include smaller weights by
increasing the number of comparison
measurements.

14

Automated mass comparators even noticeably exceed the stringent requirements for
class E1 measurement uncertainty, which
makes them suitable for use in national
primary standard laboratories.

Robots and automatic mass comparators

Application Range of Mass Comparators in Accordance with ASTM E617


CCL1007

Class 0

CCR10-1000

Class 1

CCR10

Class 2

CCR1000
CCR10K-20K
CCR10K-50K
CCR10K
CCR20K
CCR50K
CC1000S-L
CC10000U-L
CC10000S-L
CC20000S-L
CC50001S-L
CCE6

Class 0

CCE36

Class 1

CCE66

Class 2

CC111

Class 3

CC500

Class 4

Manual mass comparators

CCE1005
CCE1004
CCE2004
CCE5004
CCE5003
CC10000S
CCE10K3
CC20000
CCE40K3
CCE60K3
CCE60K2
CC64K

Class 3

CC150K

Class 4

CC300K

Class 5

CCS600K
CCT1000K
CCS1000K
CCT2000K
1
2
3
5
10
20
30
50
100
200
300
500
1
2
3
5
10
20
30
50
100
200
300
500
1
2
3
5
10
20
25
30
50
100
200
300
500
1000
2000
3000

CCS3000K

mg

Mass

kg

The chart shows the suitability of mass comparators for the ASTM E617 accuracy classes.

The results shown in this bar chart are


based on a confidence level of 95% (K=2)
and the performance of at least 3 ABBA
cycles on automatic comparators and 3
ABA cycles on manual comparators.

15

Selection of Comparators for Equipping a Mass Laboratory

Class F2

10 mg

10 mg

10 mg

100 mg

100 mg

100 mg

100 mg

1 g

1 g

5 0 kg

The bar graph shows a selection of mass


comparators that we recommend for the
various areas of application.
This page shows just a few examples of
mass comparators in our broad range.

20 g

20 g

50 g

50 g

50 g

500 g

500 g

5 0 kg

2 kg

2 kg

5 kg

1 0 kg
2 0 kg

1 kg

CCE10K3

5 kg

500 g

1 kg

1 0 kg
2 0 kg
5 0 kg

CCE40K3

2 kg

200 g

5 kg
1 0 kg
2 0 kg
5 0 kg

CCE60K2

200 g

100 g

C C E2 0 0 4

100 g

200 g

1 kg

C C E1 0 0 4

20 g

CCE40K3

CC111

CC111

CCE66

10 g

C C E6 0 K 2

2 0 kg

CC20000S-L

1 0 kg

CCR20K

5 kg

CCR10K-50K

2 kg

CC50001S-L

CC10000U-L

1 kg

5 g

10 g

CCE2004

500 g

5 g

2 g

10 g

CC10000S

200 g

5 g

100 g
Automatic mass comparators with load alternator (yellow)

100 g

CC1000S-L

50 g

Robot systems (red)

20 g

2 g

CCE1005

10 g

2 g

CCE60K3

CCR10-1000

5 g

CCE66

2 g

1 g

C C E6 6

10 mg

CCE6

1 mg

CCE6

1 mg

Manual mass comparators (blue)

1 mg

CCE2004

Ma s s

CC500

Class F1

1 mg

1 g

16

Ma s s

Class E2

CC111

Ma s s

CCE5003

Class E1

Ma s s

Accessories
Susceptometer A Complete Solution for Testing the Magnetic Properties of Weights
The OIML R111 stipulates that magnetic
properties of weights be determined prior
to mass calibration. This confirms that the
requirements placed on weights no longer
only apply to geometric quantities, material density, weight, or surface qualities. In
fact, many scientific evaluations support
the demand that both the susceptibility
and magnetization of weights be
considered.

The susceptometer method measures the


interaction between a permanent magnet
and the weight to be tested as a function
of the force exerted on a mass standard. A
high-resolution balance is used for this
test. The desired magnetic properties of the
weight can be calculated on the basis of
the known properties of the test magnet,
the distance of the weight from the test
magnet and the weight's geometry.

Susceptometer Method
There are several methods for defining the
magnetic properties of weights. The
susceptometer method is stipulated in
OIML R111 for testing weights of classes
E1, E2, F1 and F2. The new YSZ01C |
YSZ02C susceptometer from Sartorius lets
you easily and conveniently determine the
susceptibility and magnetization of weights
in accordance with OIML R111.

The Sartorius susceptometer stands out


against other well-known instruments by
virtue of its highly compact design and
integrated components. An innovative
turning mechanism for adjusting the position of the test magnet and simple adjustment of the height of the loading platform
also make working with the susceptometer
simple and effective. This design significantly improves the repeatability of measurements. The susceptometer is available
in two resolution levels. The YSZ01C features a 10-g resolution; the YSZ02C has a
1-g resolution.

Technical Specifications
Susceptometer
Readability of the susceptometer
Application range in accordance
with OIMLR 111

Application Software
The software that comes standard with
the susceptometer is exceptionally easy to
use and enables data to be automatically
transferred from the unit. It also supports
the user through all required steps and
provides assistance with settings before
and during a measurement. Menu prompts
request all relevant data and guide the user
through the steps necessary for performing
a measurement. The results of the test
are recorded and can be exported to
higher-level databases.
A User-friendly, All-in-one Solution
The YSZ01C | YSZ02C susceptometer
from Sartorius rounds off the range of
accessories for high-resolution balances
and mass comparators. Along with its
specialized software, the susceptometer
provides a unique, complete solution that
enables you to ensure that the limits of
the magnetic properties of weights are
maintained.

YSZ01C
10 g

YSZ02C
1 g

E2|F1|F2

E1|E2|F1|F2

Dimensions

338 x 286

Height

249 mm

Maximum capacity

Susceptometer in a choice of versions YSZ01C, YSZ02C

Set of 3 reference magnets YSZ01RMC

50 kg

Dipole moment of the magnet

m ~ 0.1 Am2

Geometry ratio of the magnet

Height to diameter = 0.87

Z0, distance from center of magnet


to the bottom of weight in mm

Adjustable in fixed steps:


Z1 = 18 | Z2 = 20 | Z3 = 27 | Z4 = 35 | Z5 = 43

Field strength due to different


heights Z0, in A/m

2700

| 2000

| 800

| 360

| 200

Turning mechanism for magnet

Easy to operate by external rotary knob;


marking for N-S orientation of the magnet

Software

Convenient application software; standard settings


and easy, user-defined configuration possible;
quick check function; printing of reports, exporting
of results

Data transfer protocol

HTML mode and data transfer to user-specific


metrology software via CSV file format

YSZ01RMC

3 reference magnets in a wooden case for Sartorius


susceptometer YSZ01C and YSZ02C

YSZ01RSC

1 kg reference susceptibility standard in a wooden


case for Sartorius susceptometer YSZ01C and
YSZ02C with PTB magnetic susceptibility certificate
17

Volume and Density Determination up to 1 kg


Density determination is often required in
metrology and industry. The most accurate
method for determining the density of
solid objects in accordance with OIML R111
is hydrostatic mass comparison in liquid. In
this procedure, a volume reference of
known mass and volume is compared in liquid of known density with a test object of
known mass. The volume or density of the
test weights is calculated from the different buoyancies of the weights in the liquid.
Sartorius has integrated this OIML R111
method into a fully automatic volume
comparator.

The load alternators and weighing pans are


designed as comb-type weight grabbers so
that weights and groups of weights from
1 g to 1 kg can be transferred directly from
the load alternator to the suspended weighing pan. Adapter plates are not required.
This has a positive effect on the accuracy
of the overall measurement system.
After the data has been entered, a built-in
PC with user-friendly software takes over
fully automatic control of the volume
comparator and evaluation of density
measurement.

Sartorius offers two fully automatic


systems for density determination for
weights in the range from 1 g to 1 kg:
models VD1005 and VL1005.
Both volume comparators have a nineposition load alternator in a liquid bath.
Model VD1005 also has a second nineposition load alternator for substitution
weights in air. The load alternator operates
synchronously in that a position in air
is assigned for each position in liquid. By
using substitution weights, this innovative
dual-weight alternator design makes it
possible to directly compare the mass of
a single-volume reference (e.g. silicon
sphere) with a variety of weights in liquid.

Technical Specifications:
VD1005|VL1005
Density uncertainty*
Volume uncertainty*
Weight diameter
Maximum sphere diameter

1 kg/m3
0.00015 cm3
650 mm
95 mm

VD1005|VL1005, Volume comparator

Application
Density deterimnation of weights
in accordance with OIML R111,
Class E1
1 g1 kg
Comparator Technical Specifications
Maximum capacity
1125 g
Readability
0.01 mg
Repeatability, s*
< 40 g
Repeatability (typical), s*
< 20 g
Weighing range, electronic
350 g
Tare range (subtractive)
350 g

The dual-weight alternator on model VD1005

* Partial uncertainty of the volume comparator (without references and test weights)
s* The standard deviation "s" is the repeatability calculated from 6 ABBA cycles after elimination of drift. Prerequisites for accurate calculation of the standard deviation are
good ambient conditions in accordance with OIML R111 for an E1 mass standards laboratory.

18

Accessories for Density Determination


YVT01C

Thermostat

YWT20C

Table for VD1005 and VL1005

YDR1000SIC

1 kg silicon sphere with PTB density certificate

YCS31-612-09

Set of 1g to 1kg weights with PTB density certificate

YCS51-612-02

Set of substitution weights with DKD certificate

1 kg silicon sphere, YDR1000SIC

Thermostat, YVT01C

Table for volume comparator, YWT20C

Density Determination up to 50 kg Using the YP50K Pycnometer


Sartorius offers the YP50K pycnometer for
determining the volume of weights in the
range from 2 kg to 50 kg.
In combination with the CCE60K3 and
a PC, the pycnometer is a reliable solution
for determination of volume.
All required accessories, including a sturdy
storage and shipping case, are included
as standard equipment. A PC, mass
comparator and reference weights are
not included in the standard equipment
supplied.
Software supports the user in volume
determination.

Sartorius pyconometer, YP50K

19

Software for Mass Metrology


One Software Program for All Equipment ScalesNet32
Careful acquisition of weighing data and
associated parameters is one of the most
important criteria in mass metrology. To
ensure that ScalesNet32 meets this
requirement, it was continuously tested
throughout the entire development phase
in the DKD laboratory for correct functionality and suitability in practical daily use.
These accompanying checks were carried
out in an accredited DKD laboratory and
are not only substantially responsible for
the high degree of functionality achieved,
but also provide the user with the necessary peace of mind. ScalesNet32 meets the
requirements of all quality management
systems that use calibrated weights to supply evidence of traceability to national
standards.
The calibration of a weight is always
allocated to an order or customer, the
serial number, manufacturer, shape and
features of the weight. These details are
assigned to the test object and thus guarantee clear identification. The weight data
is stored in a database; therefore, the
history of the weight can be viewed at any
time.
The mass comparators used to calibrate
weights are monitored by ScalesNet32 and
calibrated and adjusted at specified intervals. The calibration results obtained are
stored in the database.
ScalesNet32 also monitors the mass
standard and climate stations used, along
with their associated sensors. The software
informs the user of the calibrations that
are due. The reference weight standards,
climate stations and mass comparators are
blocked from use once the tolerance interval has expired. The test intervals for the
mass comparators, reference weights and
climate equipment are set by the user in
accordance with the particular
requirements.

The following functions are available


to the user:
Calibration of customer weights
On-location calibration of customer
weights
Calibration of reference weights
Subdivision of weights
Quick comparison of weights without
printed report
Calibration of weights with raw data
output
Manual input of weighing data for comparators without RS-232 connectivity
Calibration of mass comparators,
balances and scales
Adjustment of mass comparators,
balances and scales
Recording and graphic plotting of
external parameters
The principal features of ScalesNet32:
Central SQL database for storing all
measurement values and acquired information
Automatic loading of weighing data over
the RS-232 interface of the weighing
instrument. The parameters of the interface can be generated in accordance with
the weighing instrument manufacturers
data.
Automatic detection of parameters
defining ambient conditions during
weighing cycles

ScalesNet32, YSN01C

20

Number of weighing cycles and type of


weighing procedure (ABA or ABBA) can
be configured by class
Selection of classes in accordance with
OIML R111, ASTM 617 or other national
standards
Simultaneous testing of weights from a
particular weight set on multiple mass
comparators in the laboratory
Plausibility testing after the reference
weight set and weighing instrument have
been selected (i.e., Are both the instrument and the reference suitable for this
class?)
Test records generated for each weight
tested; records include all data acquired
during testing (reference weight,
weighing instrument used, temperature,
humidity, air pressure, etc.)
The history of each weight tested can
be viewed
User-configurable certificates of verification, inspection, calibration or DKD calibration as Word templates; the data and
test results are positioned in the Word
template with bookmarks, which are
replaced by measured values or other
data when the report is printed; bilingual
DKD certificates can be generated.
Automatic generation of inventory
lists of the weighing instruments and
reference weights used
Monitoring of calibration intervals for
the mass comparators, reference weight
sets and climate stations used

Components of ScalesNet32
ScalesNet32-Desk
Module for the administration of all master
data and orders, including all printouts.
Connectivity to the ScalesNet32 database
server is provided via Ethernet.
ScalesNet32-Mass
This module is designed for handling the
calibration of test objects and mass standards as well as calibration and adjustment
of comparators. Connectivity to the
ScalesNet32 database server is provided
via Ethernet or WLAN.
Climate Station (optional)
Collects the environment data of the
weighing laboratory. The environment
parameters are called up during a
measurement cycle and combined with
the weighing data. If a climate system
that is not compatible with the system
is used, a datalogger and converter combination is required to convert climate data
into a format that ScalesNet32 can read.

RS-232C

RS-232C

Server

Climate Station
Hub
Ethernet LAN
ScalesNet32 Version IV

Software for Mass Comparison - YPR02C


This application software is designed for
highly accurate online determination of
mass using Sartorius manual mass comparators and for controlling automatic comparisons of mass in conjunction with Sartorius
automatic mass comparators. It runs on
Microsoft Windows 2000 or XP.
The software facilitates the determination
of the difference between two masses and
the determination of absolute or apparent
mass (conventional mass value), taking
buoyancy errors into account. The program
automatically implements buoyancy corrections after manual entry of the climate
data or automatic acquisition of climate
data using the climate station YCM02C or
YSM03C.

The time at which the mass comparison


takes place and the maximum uncertainty
for automatic mass comparison are
selectable.
The standard software contains a database
for reference and test weights, and
facilitates online calculation of the
standard deviation and mass difference
and the uncertainties at either the sigma 1,
sigma 2 or sigma 3 level.
The number of ABBA or ABA cycles can be
selected in the range from 0199.

Software, YPR02C

21

Accessories for Mass Metrology


Mass Standards and Weights
Sartorius offers weights and mass standards in conformance with OIML R 111
in all accuracy classes ranging from E1
to M2 and from 1 mg to 1000 kg.
M class mass standards are available up
to 1000 kg in a variety of shapes, sizes
and materials.

Class E1 and E2 sets are available in various


weight combinations.
All weights are available individually, with
or without DKD or PTB certification.
Please consult our separate brochure
for details or visit our website at
www.sartorius.com.

A Sampling of Our Range of Weights Offered


Nominal Value

Order No.
E1

Order No.
DKD-calibrated
E1

Order No.
DKD-calibrated
E2

1 mg 5 g

YCS011-351-00

YCS011-351-02

YCS011-352-00

1 mg 100 g

YCS011-511-00

YCS011-511-02

YCS011-512-00

1 mg 200 g

YCS011-521-00

YCS011-521-02

YCS011-522-00

1 mg 1 kg

YCS011-611-00

YCS011-611-02

YCS011-612-00

1 mg 5 kg

YCS011-651-00

YCS011-651-02

YCS011-652-00

1 g 1 kg

YCS31-611-00

YCS31-611-02

YCS31-612-00

1 g 5 kg

YCS31-651-00

YCS31-651-02

YCS31-652-00

1 g 10 kg

YCS31-711-00

YCS31-711-02

YCS31-712-00

Set of weights, YSC011-611-00

Convenient Lifting Devices


Weight forks for 500 g

YAW41

Weight forks for 1 kg

YAW42

Weight forks for 2 kg

YAW43

Weight forks for 5 kg

YAW50

Handle for lifting weights for 10 kg

YAW51

Handle for lifting weights for 20 kg

YAW52

Handle for lifting weights 50 kg

YAW53

Crane with chain hoist

YLD01C

Gripper for weights with handle

YLD02C

This climate measurement station with


continuous, simultaneous recording of air
pressure, room temperature and relative
humidity is available in two versions:
YCM02C and YCM03C.

The YCM03C climate measurement


station is a cost-effective alternative
for calibration laboratories and legal
verification authorities that calibrate
class F weights in compliance with OIML E2.

YCM02C delivers the greatest accuracy


and is preferred by national primary standard laboratories that calibrate with OIMLcompliant class E1 weights.

The YCM03C climate measurement station


contains a precision barometer combined
with a temperature and humidity sensor.
Up to nine additional temperature sensors
or combined temperature/humidity sensors
can be connected.

The YCM02C climate measurement


station consists of a psychrometer for
temperature and humidity, a precision
barometer and front display with keypad.
Up to nine additional temperature sensors
can be attached.
22

Climate measurement station, YCM02C

Order No.
Weighing Tables
Weighing table made of cast stone (L + W + H) 900 + 600 + 760 mm

YWT03

Weighing table (W + D + H) 900 x 750 x 750


with cast stone stab (W + D) 600 x 500

YWT09

Weighing table for volume comparator (W + D + H) 1500 + 800 + 600 mm YWT20C


Draft Shields
for CC6, SE2, ME5, SC2, CCE6

YDS20C

for CC21; CC50, CC111, CC310, CC500

YDS22C

for CC1201, CC2001, CC5001, CCE1004, CCE2004, CCE5004, CCE5003

YDS24C

for CCE36, CCE66, CCE1005, ME235S

YDS26C

for CC1000S-L

YDS44C

for CC64K

YDS62C

for CC150K|CC300K

YDS64C

for CCS600K|CCS1000K

YDS80C

for CCT1000K

YDS85C

for CCT2000K

YDS87C

for CCS3000K

YDS82C

for CC30002, CC50002, CCE40K3, CCE60K3, CCE60K2

YDS03C

for CCE40K3, CCE60K3, CCE60K2, CCE10K3

YDS05C

1 kg silicon sphere, YDR1000SIC

Mass comparators, CCE5004 + draft shield, YDS24C

Density Standards
1000 g silicon sphere

YDR1000SIC

500 g silicon sphere

YDR500SIC

200 g silicon sphere

YDR200SIC

1000 g Zerodur sphere

YDR1000C

500 g Zerodur sphere

YDR500C

200 g Zerodur sphere

YDR200C

Set of weights from 1g to 1kg with PTB density certificate

YCS31-612-09

Special Weighing Pans


Weighing pan with set of weighing plates for weighing
mass combinations for CC1000S-L

YWP04C

Centering pan for CC30002 |CC50002 and CCE40K3, CCE60K3|CCE60K2

YWP03C

Printers
Data printer, with real-time clock for printing out date and time, and for
statistical evaluation of weight values

YDP03-OCE

Switches
Foot switch with T-connector

YFS01

Hand switch with T-connector

YHS02

Density Determination
Hook for below-balance weighing for CC30002 |CC50002
and CCE40K3, CCE60K3 |CCE60K2

69EA0040

Density kit for CCE36, CCE66, CC111, CC500

YDK01LP
23

Technical Specifications:
1 kg Prototype Mass Comparator and Robot

CCL1007

CCR10-1000
CCR10
CCR1000

CCR10K-20K
CCR10K-50K
CCR20K
CCR10K
CCR50K

Maximum capacity

1031 g

10.5 g

1002 g

20.05 kg

10.05 kg

51 kg

Application range

1 mg1 kg

1 mg10 g

10 g1 kg

10 kg|20 kg

1|2|3|5|6|10 kg

20|50 kg

Readability

0.1 g

0.1 g

1 g

0.1 mg

10 g

1 mg

Repeatability, s*

< 0.2 g

< 0.3 g

< 0.3 mg

< 50 g

< 3 mg

Repeatability (typical), s* < 0.1 g

< 0.2 g

0-100 g : < 3 g
< 8 g
< 2 g

< 0.1 mg

< 30 g

< 1 mg

Electronic weighing|
taring range

2g

3.5 g

2g

60 g

60 g

51 kg

Magazine positions

39

21

10

Optional magazine
positions

26-65

2-39

2-10

2-10

2-10

Substitution weights

External

2+3.5 g

30|40|50|100|
100|300|400 g

10 kg

1|1|2|1|4 kg

Linearity

1 g

1 g

20 g

3 mg

0.3 mg

50 mg

Range sensitivity

0.2 g /500 mg

0.1 g /10 mg

2 g/500 mg

0.2 mg/1 g

0.03 mg/1 g

5 mg /50 g

Stabilization time in s

60

15

25

10

20

10

Cycle time ABBA in s

480

240

240

240

240

360

Calibration weight
optional

1 g Built-in

2 g|E2
YCW322-00

2 g|E2
YCW322-00

50 g|E2
YCW452-00

50 g|E2
YCW452-00

50 kg|E2
YCW752-00

Interfaces

LAN|USB|
RS-232

LAN|USB|
RS-232

LAN|USB|
RS-232

LAN|USB|
RS-232

LAN|USB|
RS-232

LAN|USB|
RS-232

Centermatic

Yes

No

Yes

Yes

Yes

Yes

Draft shield

Vacuum chamber Yes, 2+

Yes, 2+

Yes, 2+

Yes, 2+

Yes

PC|Software

Yes|Yes

Yes|Yes

Yes|Yes

Yes|Yes

Yes|Yes

Standard Accessories

Yes|Yes

Optional Accessories
Climate station

Climate station for an E1 lab.: YCM02C; climate station for an E2 lab.: YCM03C

Software for PC

ScalesNet32, metrological control and evaluation software with database, YSN01C

Miscellaneous

Vacuum pump

Additional magazine positions

Weighing pan

3-point

52+24 mm

104+68 mm

200

200

300

Sample size (D+H)

34 - 95+100 mm

18+20 mm

100+120 mm

200+300 mm

200+300 mm

330+300 mm

(W+D+H) in mm

940+840+1100

1800+1150+1800 1800+1150+1800 Customer-specific

Dimensions

Customer-specific Customerspecific

s* The standard deviation "s" is the repeatability calculated from 6 ABBA cycles after elimination of drift. Prerequisites for accurate calculation of the standard deviation are
good ambient conditions in accordance with OIML R111 for an E1 mass standards laboratory.

24

Technical Specifications:
Mass Comparators with Load Alternator

CC1000S-L

CC10000U-L

CC10000S-L

CC20000S-L

CC50001S-L

1.002

10.05

10.05

20.05

51

100|200|300|500|
600|1000 g

1|2|3|5|6|10 kg

1|2|3|5|6|10 kg

10|20 kg

051 kg

0.001

0.01

0.1

0.1

Repeatability, s*
mg
Repeatability (typical), s* mg

< 0.002
< 0.001

< 0.05
< 0.02

< 0.1
< 0.05

< 0.3
< 0.1

<3
<2

Electronic weighing|
taring range

60

60

60

51000

Load alternator

pos.

Linearity

mg/g

0.02/0.5

0.3/50

0.3/50

3/50

50/50

Range sensitivity

mg/g

0.001/0.01

0.03/1

0.1/1

0.2/1

5/50

Stabilization time

25

20

10

10

10

Cycle time ABBA

240

240

240

240

720

Interfaces

RS-232C

RS-232C

RS-232C

RS-232C

RS-232C

Centermatic

Built-in

Built-in

Built-in

Built-in

Built-in

Draft shield

Integrated

Integrated

Integrated

Integrated

Integrated

Control unit

Integrated

Integrated

Integrated

Integrated

Integrated

Printer

Integrated

Integrated

Integrated

Integrated

Integrated

Climate station

YCM02C

YCM02C

YCM02C

YCM02C

YCM02C

Software for PC

YSN01C

YSN01C

YSN01C

YSN01C

YSN01C

Draft shield

YDS44C

Calibration weight

2 g|E2
YCW322-00

50 g|E2
YCW452-00

50 g|E2
YCW452-00

50 g|E2
YCW452-00

50 kg|E2
YCW752-00

Maximum capacity

kg

Application range
Readability

mg

Standard Accessories

Optional Accessories

Dimensions
Weighing pan d

mm

200

200

200

70

Sample size (D+H)

mm

70+130

320+300

320+300

320+300

320+300

Weigh cell (W+D+H)

mm

230+365+510

790+720+430

790+720+430

790+720+430

1500+670+915

Display (W+D+H)

mm

360+310+150

360+310+150

360+310+150

360+310+150

360+310+150

s* The standard deviation "s" is the repeatability calculated from 6 ABBA cycles after elimination of drift. Prerequisites for accurate calculation of the standard deviation are
good ambient conditions in accordance with OIML R111 for an E1 mass standards laboratory.

25

Technical Specifications:
Mass Comparators up to 1 kg

CCE6

CCE36 |CCE66

CC111

CC500

CCE1005

111

505

1105

Maximum capacity

6.1

31|61

Application range

06

030|060

0100

0500

01100

Readability

mg

0.0001

0.001

0.001

0.01

0.01

Repeatability, s*

Repeatability (typical), s* g

02 g : < 0.2
< 0.3
< 0.15

02 g : < 1
<3
<1

010 g : < 10
< 20
< 10

050 g : < 15
< 20
< 10

Electronic weighing|
taring range

6.1

26

205

605

Substitution weights

50|20|10

200|100

500

Linearity

6|10

10

100

100

Range sensitivity

g/mg

0.2/5

2/10

2/10

10/1000

10/2000

Stabilization time

10

15

10

15

02 g : < 1
< 2|< 3
<1
31|61

15

Standard Accessories
Interfaces

2+RS-232C

2+RS-232C

RS-232C

RS-232C

2xRS-232C

isoCAL**

Integrated

Integrated

Integrated

Below-balance
weighing

Included

Included

Included

Included

Centermatic

Draft shield

Electric

Electric

Integrated

Integrated

Electric

Application Software

Built-in

Built-in

Built-in

Climate station

YCM02C

YCM02C

YCM02C

YCM02C

YCM02C

Software for PC

YSN01C

YSN01C

YSN01C

YSN01C

YSN01C

Draft shield

YDS20C

YDS26C

YDS22C

YDS22C

YDS26C

Calibration weight

5 g|E2
YCW352-00

20 g|E2
YCW422-00

200 g|E2
YCW522-00

500 g|E2
YCW552-00

50

90

90

50+120

135+140

90+200

Included

Optional Accessories

20 g E2|50 g E2
YCW422-00|YCW452-00

Dimensions
Weighing pan d

mm

16

Sample size (D+H)

mm

16+70

Weigh cell (W+D+H)

mm

122+315+122

222+439+302

219+408+318

219+408+318

222+439+302

Display (W+D+H)

mm

254+320+106

254+320+106

213+307+107

213+307+107

254+320+106

30
30+120

s* The standard deviation "s" is the repeatability calculated from 6 ABA cycles after elimination of drift. Prerequisites for accurate calculation of the standard deviation are
good ambient conditions in accordance with OIML R111 for an E1 mass standards laboratory.
** isoCAL fully automatic internal calibration and adjustment

26

Technical Specifications:
Mass Comparators from 1 kg to 10 kg

CCE1004

CCE2004

CCE5004

CCE5003

CCE10K3

Maximum capacity

1200

2500

5100

5100

10100

Application range

01200

02500

05100

05100

010000

Readability

mg

0.1

0.1

0.2

Repeatability, s*

mg

< 0.1

< 0.2

<1

<2

Repeatability (typical), s* mg

< 0.05

< 0.1

01 kg : < 0.3
< 0.5
< 0.3

< 0.5

<1

Electronic weighing|
taring range

1200

2500

5100

5100

10100

Linearity

mg

50

Range sensitivity

mg/g

0.1/2

0.1/2

0.5/10

1/10

2/10

Stabilization time

10

10

10

10

10

Interfaces

2+RS-232C

2+RS-232C

2+RS-232C

2+RS-232C

2+RS-232C

isoCAL**

Integrated

Integrated

Integrated

Integrated

Below-balance
weighing

Included

Included

Included

Included

69EA0040
hook

Centermatic

Draft shield

Built-in

Built-in

Built-in

Built-in

Application Software

Built-in

Built-in

Built-in

Built-in

Built-in

Climate station

YCM02C

YCM02C

YCM02C

YCM02C

YCM02C

Software for PC

YSN01C

YSN01C

YSN01C

YSN01C

YSN01C

Draft shield

YDS24C

YDS24C

YDS24C

YDS24C

YDS05C

Calibration weight

1 kg|E2
YCW612-00

2 kg|E2
YCW622-00

5 kg|E2
YCW652-00

5 kg|E2
YCW652-00

10 kg|E2
YCW712-00

Standard Accessories

Optional Accessories

Dimensions
Weighing pan

mm

d 130

d 130

d 130

d 130

350+240

Sample size (D+H)

mm

130+200

130+200

130+200

130+200

200+300

Weigh cell (W+D+H)

mm

240+260+355

240+260+355

240+260+355

240+260+355

350+240+133

Display (W+D+H)

mm

254+320+106

254+320+106

254+320+106

254+320+106

254+320+106

s* The standard deviation "s" is the repeatability calculated from 6 ABA cycles after elimination of drift. Prerequisites for accurate calculation of the standard deviation are
good ambient conditions in accordance with OIML R111 for an E1 mass standards laboratory.
** isoCAL fully automatic internal calibration and adjustment

27

Technical Specifications:
Mass Comparators from 10 kg to 60 kg

CC10000S

CC20000

CCE40K3

CCE60K3|CCE60K2

Maximum capacity

kg

10.05

20.05

41

Application range

kg

1|2|3|5|6|10

10|20

041

Readability

mg

0.1

Repeatability, s*

mg

< 0.25

< 2.5

<5

Repeatability (typical), s*

mg

< 0.1

<1

<3

Electronic weighing|
taring range

60

60

41000

10 kg

70

Substitution weights

64
064
2|10
010 kg : < 4|< 10
< 7|< 10
< 4|< 7
64000

Linearity

mg/g

0.3/50

3/50

50

Range sensitivity

mg/g

0.1/1

1/1

10/100

Stabilization time

10

10

Interfaces

RS-232C

RS-232C

2+RS-232C

2+RS-232C

Below-balance
weighing

69EA0040
hook

69EA0040
hook

Centermatic

Built-in

Built-in

Draft shield

Built-in

Built-in

Application Software

Built-in

Built-in

Climate station

YCM02C

YCM02C

YCM02C

YCM02C

Software for PC

YSN01C

YSN01C

YSN01C

YSN01C

Draft shield

YDS05C

YDS05C

Calibration weight

50 g|E2
YCW452-00

50 g|E2
YCW452-00

10 kg|E2
YCW712-00

20/100
10

Standard Accessories

Optional Accessories

20 kg|E2
YCW722-00

Dimensions
Weighing pan

mm

d 200

d 200

400+300

400+300

Sample size (D+H)

mm

200+300

200+300

400+300

400+300

Weigh cell (W+D+H)

mm

230+365+470

230+365+470

400+300+120

400+300+120

Display (W+D+H)

mm

213+307+107

213+307+107

254+320+106

254+320+106

s* The standard deviation "s" is the repeatability calculated from 6 ABA cycles after elimination of drift. Prerequisites for accurate calculation of the standard deviation are
good ambient conditions in accordance with OIML R111 for an E1 mass standards laboratory.

28

Technical Specifications:
Mass Comparators from 60 kg to 300 kg

CC64K

CC150K

CC300K

Maximum capacity

kg

64

151

303

Application range

kg

064

0151

0303

Readability

0.05

0.1

Repeatability, s*
Repeatability (typical), s*

g
g

< 0.15
< 0.1

< 0.3
< 0.2

<1
< 0.5

Electronic weighing|
taring range

kg

64

151

303

Linearity

2.4

Range sensitivity

g/kg

0.3/1

0.3/1

2/1

Stabilization time

10

10

10

Interfaces

RS-232C|RS-485

RS-232C|RS-485

RS-232C|RS-485

Application Software

Centermatic

YWP03C

Climate station

YCM03C

YCM03C

YCM03C

Software for PC

YSN01C

YSN01C

YSN01C

Draft shield

YDS62C

YDS64C

YDS64C

Calibration weight

20 kg|F1
YCW723-00

50 kg|F1
YCW753-00

2+50 kg|F1
YCW753-00

Standard Accessories

Optional Accessories

Dimensions
Weighing pan (side)
or (W+D)

mm

560+450

800+600

800+600

Display (W+D+H)

mm

337+225+151

337+225+151

337+225+151

s* The standard deviation "s" is the repeatability calculated from 6 ABA cycles after elimination of drift. Prerequisites for accurate calculation of the standard deviation are
good ambient conditions in accordance with OIML R111 for an E1 mass standards laboratory.

29

Technical Specifications:
Mass Comparators from 600 kg to 3000 kg

CCS600K

CCT1000K

CCS1000K

CCT2000K

CCS3000K

Maximum capacity

kg

605

1200

1510

2010

3010

Application range

kg

0605

01200

01510

02010

03010

Readability

10

Repeatability s*
g
Repeatability (typical), s* g

< 2,5
<2

<3
<2

<6
<5

<8
<5

< 12
< 10

Electronic weighing|
taring range

kg

605

1200

1510

2010

3010

Stabilization time

20

30

20

30

20

RS-232C|RS-485

RS-232C|RS-485

RS-232C|RS-485

RS-232C|RS-485

RS-232C|RS-485

Climate station

YCM02C

YCM02C

YCM02C

YCM02C

YCM02C

Software for PC

YSN01C

YSN01C

YSN01C

YSN01C

YSN01C

Draft shield

YDS80C

YDS85C

YDS80C

YDS87C

YDS82C

Calibration weight

YCW853-02

YCW913-02

YCW913-02

YCW913-02

YCW913-02

Standard Accessories
Interfaces
Optional Accessories

Dimensions
Weighing pan (side)
or (W+D+H)

mm

800+1000+300

1510+1310+300

800+1000+300

1920+1660+300

1000+1250+300

Display (W+D+H)

mm

303+195+90

303+195+90

303+195+90

303+195+90

303+195+90

s* The standard deviation "s" is the repeatability calculated from 6 ABA cycles after elimination of drift. Prerequisites for accurate calculation of the standard deviation are
good ambient conditions in accordance with OIML R111 for an E1 mass standards laboratory.

30

Technical Specifications:
Determination of Volume, Density, Susceptibility and Magnetism

VD1005

VL1005

YP50K

YSZ01C

YSZ02C

1.125

1.125

50

50

50

1 g 1 kg

1 g1 kg

2 kg50 kg

E2|F1|F2

E1|E2|F1|F2

10

10

10

Repeatability s*
g
Repeatability (typical), s* g

< 40
< 20

< 40
< 20

< 20
< 10

<8
<5

El. weighing|taring range g

350

350

10

10

Load alternator

pos.

9 in liquid
9 in air

9 in liquid

Linearity

mg

0.12

0.12

0.1

0.05

Range sensitivity

g/g

20/1

20/1

20/1

10/1

Stabilization time

20

20

15

15

Interfaces

RS-232|USB|LAN

RS-232|USB|LAN

RS-232C

RS-232C

Draft shield

Integrated

Integrated

Integrated

Integrated

PC|Application Software

Yes|Yes

Yes|Yes

No|Yes

No|Yes

No |Yes

Miscellaneous

Air temperature sensor


Air humidity sensor
Air pressure sensor
2 temperature sensors in liquid
PT100 1 mK
Meniscus compensation

Aluminum case
Lifting aid
Metering syringe
Temperaturemeasuring device
Gloves
Test certificate

RS232 PC connection cable


Susceptometer test certificate
Neodymium-iron-boron magnet
5 different distances Z0
(gauge blocks not necessary)

Climate station

YCM02C

YCM02C

YCM03C

YCM03C

YCM02C

Software for PC

YSN01C

YSN01C

YSN01C

YSN01C

Calibration weight

200 g|E2
YCW522-00

200 g|E2
YCW522-00

10 g|E2
YCW412-00

10 g|E2
YCW412-00

Miscellaneous

YVT01C, thermostat
YWT20C, table for VD1005 & VL1005
YDR1000SIC, 1 kg silicon sphere
with PTB density certificate
YCS31-612-09, set of weights,
1g-1kg with PTB density certificate
YCS51-612-02, set of
substitution weights

CCE60K3
YLD01C, crane
up to 50 kg
YLD02C,
crane gripper
for weights

YSZ01RMC, calibration kit for the


internal magnet
YSZ01RSC, 1 kg susceptibility
standard (1kg)
YLD01C, crane up to 50 kg
YLD02C, crane gripper for weights

95+120

95+120

210+350

300+350

300+350

Measurem. unit (W+D+H) mm

600+600+1600

600+600+1600

340+300+250

340+300+250

Control unit (W+D+H)

600+600+1600

600+600+1600

160+140+40

160+140+40

Maximum capacity

kg

Application range
Readability

Standard Accessories

Optional Accessories

Dimensions
Sample size (D+H)

mm

mm

s* The standard deviation "s" is the repeatability calculated from 6 ABBA cycles after elimination of drift. Prerequisites for accurate calculation of the standard deviation are
good ambient conditions in accordance with OIML R111 for an E1 mass standards laboratory.

31

Sartorius AG
Weender Landstrasse 94108
37075 Goettingen, Germany
Phone +49.551.308.0
Fax +49.551.308.3289
www.sartorius-mechatronics.com
www.massmetrology.com

Sartorius AG reserves the right


to make changes to the technology,
features, specifications and design
of the equipment without notice
Specifications subject to change without notice.
Printed in Germany on paper that has been
bleached without any use of chlorine.
W/sart-289 G
Publication No.: W--1064-e07119
Order No.: 98649-001-54

You might also like