Design of Beam: Mu B× D ×D

The document summarizes the design calculations for reinforcing steel in a concrete beam. It determines: 1) The maximum positive and negative bending moments and shear force on the beam. 2) The required area of longitudinal reinforcing steel for the positive (374.625mm2) and negative (694.125mm2) moments. 3) The required shear reinforcement of 8mm diameter stirrups spaced at 200mm centers to resist the maximum shear force of 124kN.

Uploaded by

Shashank Patole
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
87 views2 pages

Design of Beam: Mu B× D ×D

The document summarizes the design calculations for reinforcing steel in a concrete beam. It determines: 1) The maximum positive and negative bending moments and shear force on the beam. 2) The required area of longitudinal reinforcing steel for the positive (374.625mm2) and negative (694.125mm2) moments. 3) The required shear reinforcement of 8mm diameter stirrups spaced at 200mm centers to resist the maximum shear force of 124kN.

Uploaded by

Shashank Patole
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

Design of Beam

Maximum -ve Bending Moment is 99Kn-m


Maximum +ve Bending Moment is 62.416kn-m
Maximum Shear Force is 123.315kn
Calculation of +ve steel:

Mu
63 100000
=
=1.315 N /mm 2
b d d 300 400 400
From SP 16 table 3 For M25 Concrete and Fe 500 Steel
Pt = 0.333 hence

Ast =

Pt b d 0.333 300 375


=
100
100

Ast = 374.625mm2
Hence Providing 2no of 16mm dia bars for full Length of the Beam
Calculation of -ve steel:

Mu
98.074 100000
=
=2.33 N /mm 2
b d d 300 400 400

Pt = 0.617 hence

Ast=

Pt b d 0.617 300 375


=
100
100

Ast = 694.125mm2
Hence Providing 2no of 16mm dia bars for full Length of the Beam and 2no of
16mm dia bars near Supports
Calculation of Shear Reinforcement:

vu=

Vu
124 1000
=
=1.102 N /mm 2
b d 300 375

For M25

cmax=1.102 N /mm 2

For Pt = 0.60 and For M25 From SP16

Vus=

C=0.53

(vuc) b d (1.1020.53) 300 375


=
100
1000

Vus= 64.35kn

Vus 64.35
kn
=
=1.716( )
d
37.5
cm

Hence From SP16 provide 8mm dia Bars, 2 legged stirrups at 200mm c/c