Main Pump of DL Loader
Main Pump of DL Loader
Main Pump of DL Loader
DL series
Jan., 24th,2007
Overseas P/S Team
Main pump
- Summary
Model
Pump Type
QTY
DL200
Parker
DL250
Denison
DL300
Denison
DL400
DL500
Function
Maker
Rexroth
Rexroth
2
Main pump
1) DL200 Main pump ( Parker)
Triple gear pump.
Main pump
1) DL200 Main pump ( Parker)
Pump exterior.
Main pump
1) DL200 Main pump ( Parker)
Pump schematic.
Main pump
1) DL200 Main pump ( Parker)
Gear pump oil flow (Fixed oil flow pump)
Flow
Q
Q=qXn
Let the efficiency be 1.0
Q : flow (l/min, rpm)
n : input shaft speed (rev/min)
q : displacement (cc/rev)
n
5
Main pump
2) DL250 / 300 Main pump (Dension)
Triple vane pump.
Discharge
Suction
Suction
Discharge
Main pump
2) DL250 / 300 Main pump (Dension)
Triple vane pump.
1. Pressure to insert.
3. Rotor .
5. Ring.
7. Bottom pressure.
2. Vane.
4. Rotation direction.
6. Sharper edges.
Main pump
2) DL250 / 300 Main pump (Dension)
Pump exterior.
Discharge port
Suction port
Discharge port
(For loading)
Discharge port
(For steering)
Main pump
2) DL250 / 300 Main pump (Dension)
Pump schematic.
Main pump
2) DL250 / 300 Main pump (Dension)
Pump oil flow (Fixed oil flow pump)
Flow
Q
Q=qXn
Let the efficiency be 1.0
Q : flow (l/min, rpm)
n : input shaft speed (rev/min)
q : displacement (cc/rev)
n
10
Main pump
3) DL400 / 500 Main pump (Rexroth)
Theory of orifice.
Lets think about A & B pressure depends on orifice size (Completely open, orifice & closed)
- Completely open A (
- Orifice A (
)B
- Closed A (
)B
)B
Orifice
11
Main pump
3) DL400 / 500 Main pump (Rexroth)
Theory of LS system - Flow control (Load Sensing system)
Lets think about P between P1 and P2 depends on orifice size
(Completely open, orifice & closed)
P1
P2
Max
12
Main pump
3) DL400 / 500 Main pump (Rexroth)
Theory of LS system - Pressure control (Load Sensing system)
Setting force
250 bar
Open
Min
Max
13
Main pump
3) DL400 / 500 Main pump (Rexroth)
Pump exterior ( I )
Drain port
LS Signal port
Suction port
14
Main pump
3) DL400 / 500 Main pump (Rexroth)
Pump exterior ( II )
Not use
LS
signal
Port
Suction port
Out let port
Main pump
3) DL400 / 500 Main pump (Rexroth)
Pump internal section.
Out let port
Suction port
LS Signal port
Main pump
3) DL400 / 500 Main pump (Rexroth)
Pump inner parts.
17
Main pump
3) DL400 / 500 Main pump (Rexroth)
Schematic.
LS signal port
Flow control spool
Control valve
S1
L1
18
Main pump
3) DL400 / 500 Main pump (Rexroth)
Schematic (Flow control)
0 bar LS signal
Min
S1
L1
19
Main pump
3) DL400 / 500 Main pump (Rexroth)
Schematic (Flow control)
0 bar LS signal
High LS signal :
Increase / Decrease oil flow
Min
Max
S1
L1
20
Main pump
3) DL400 / 500 Main pump (Rexroth)
Flow control curve (Related with LS pressure) - dotted line
21
Main pump
3) DL400 / 500 Main pump (Rexroth)
Schematic (Pressure control)
Above 250 bar :
Decrease (minimum) oil flow
Min
22
Main pump
3) DL400 / 500 Main pump (Rexroth)
Pressure control curve (Related with system pressure)
0 bar
250 bar
23