Motor Fault Simulator L Low Voltage Fault Simulation Trainer (XPO - MFS)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Motor Fault Simulator l Low voltage Fault

Simulation Trainer (XPO - MFS)

SALIENT FEATURES
u Easy and safe wiring by students due to 4mm sturdy shrouded banana patch cords and shrouded socket arrangement
for high voltage circuits.
u Facilitates easy learning about fault characteristics of ubiquitous squirrel cage induction motor.
u Teaches troubleshooting through introduction of fault switches.
u Each panel has ABS molded plastic sturdy enclosure, and colorful screw less overlays showing circuit diagram & its
connection tag numbers for easy understanding and connections.
u Set of Instructor Guide & Student Workbook.
TECHNICAL SPECIFICATIONS
A] Aluminum profile flat demo panel system (table top),
carrying various high voltage components housed in
plastic enclosures (panel) to minimize shock
possibility.
u Input 3 phase DOL Starter panel (EMT1)
l 4 pole MCB of 415 V/1A .
l DOL 9A Contactor with 230V / 50 Hz / 11VA COIL.
l Bimetallic thermal O/L relay with range 1.4A - 2.3A .
u AC voltmeter panel (EMT2)
l AC voltmeter of 0-600V for three phase voltage
measurement by selector switch.
l The selector switch facilates monitoring all three line
voltages namely RY, YB and BR as well as 1 phase voltage
monitoring.
u AC Ammeter panel (EMT3)
l AC Ammeter of 2A/6A for three phase current
measurement by selector switch.
l The selector switch facilates monitoring all the three line
currents.
l The panel also facilate single phase current monitoring
along with thermal output of rating 2A, 4A, 6A.
u FWD/REV, Star-Delta starter panel (EMT 4)
l FWD/REV, 3 pole 3 way switch with centre OFF,
6A/440V.
l Star/Delta switch 3 pole, 3 way with centre OFF,

3 Phase sequence indicator Panel (P30)


l Study 3 phase 440V Electric utility supply
Determination of over voltage, under voltage, single
phasing and reverse phasing / Displays OV, UV, SP, RP
on digital display
Motor
l 3 phase squirrel cage induction motor, HP, 4 pole,
1500RPM, 6 terminal (delta 220Vac/star 440Vac) motor
with built in thermal cutout (NC contact).

Fault simulator built on the panel on top of motor


shrouded under cover.

Study toggle switches to introduce faults.

List of faults:
1) Over current.
2) Under current.
3) High. Temperature
4) Single phasing
5) Reverse phasing
6) Under voltage.
7) Over voltage
8) Winding open

MECHANICAL SPECIFICATIONS
l

Aluminum rack of 4 X 2 matrix used as flat demo panel


system to house panels needed for the trainer ordered.
Dimensions : 500(H) X 910(L) X 300(D)mm

You might also like