0% found this document useful (0 votes)
241 views

Sparger Calc Mot

This document contains calculations for determining the required surface area of a sparger used in a reactor tank. It lists input values like gas flow rate, liquid head, pressures, and agitator specifications. It then calculates the gas exit velocity and determines that a sparger area of 20.09 square feet or 1.87 square meters is needed. It also specifies designing the sparger diameter to be 50 mm and length to be 11.8859 meters.

Uploaded by

Rajesh Nare
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
241 views

Sparger Calc Mot

This document contains calculations for determining the required surface area of a sparger used in a reactor tank. It lists input values like gas flow rate, liquid head, pressures, and agitator specifications. It then calculates the gas exit velocity and determines that a sparger area of 20.09 square feet or 1.87 square meters is needed. It also specifies designing the sparger diameter to be 50 mm and length to be 11.8859 meters.

Uploaded by

Rajesh Nare
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 5

N2 Supply pressure

Pressure in reactor
Normal liquid level in reactor
Static head
Total pressure above sparger
allowable pressure drop in line

1
0.02
2400
21919.46
0.223666
0.243666
0.756334

Kg/cm2
Kg/cm2
mm
Pa
Kg/cm2
Kg/cm2
Kg/cm2

Sparger surface area calculation


Gas flow rate
Liquid head in tank
Liquid pressure at sparger
Head space pressure
Total pressure
Liquid temperature
ACFM
RPM
agitator dia
Agitator tip speed
GAS exit velocity ( from chart)
design
max
Sparger area required

Diameter of sparger
Length required

2064 m3/hr
1214.664 SCFM
3m
9.84252 ft
3.967746 PSIG
0 PSIG
3.967746 PSIG
86 degF
1004.317
64
56.69 inch
15.84349 FPS
50 FPM
150 FPM
20.09 ft2
1.87 m2
50 mm
0.05 m
11.8859 m

In tank Not agitated


Design
5 to 10
FPM
Max
25 FPM
In tank agitated
If
1 to 5 FPS

Then
Design
Max

25 FPM
50 FPM

5 to 10 FPS

Design
Max

25 FPM
100 FPM

>10 FPS

Design
Max

50 FPM
150 FPM

Sparger surface area calculation


Gas flow rate
Liquid head in tank
Liquid pressure at sparger
Head space pressure
Total pressure
Liquid temperature
ACFM
RPM
agitator dia
Agitator tip speed
GAS exit velocity ( from chart)
design
max
Sparger area required

Diameter of sparger
Length required

2064 m3/hr
1214.664 SCFM
3m
9.84252 ft
3.96774619 PSIG
0 PSIG
3.96774619 PSIG
86 degF
1004.3172137
64
56.69 inch
15.84349345 FPS
50 FPM
150 FPM
20.09 ft2
1.87 m2
50 mm
0.05 m
11.88587469 m