Experiment 1 - Infiltration Test
Experiment 1 - Infiltration Test
TECHNOLOGY
LABORATORY: HYDRAULICS
AND HYDROLOGY
EXPERIMENT: INFILTRATION
TEST
EDITION:
REVISION NO:
EFFECTIVE DATE:
AMENDMENT
BNP 20103
EXPERIMENT NO.
EXPERIMENT TITLE
INFILTRATION TEST
DATE
GROUP NO.
LECTURER/ INSTRUCTOR/
TUTOR
DATE OF REPORT
SUBMISSION
DISTRIBUTION OF MARKS
FOR LABORATORY REPORT
EXAMINER COMMENTS:
1)
2)
ATTENDANCE/PARTICIPATION/DISPLINE
INTRODUCTION:
PROCEDURE:
RESULTS & CALCULATIONS
ANALYSIS
DISCUSSIONS:
ADDITIONAL QUESTIONS:
CONCLUSION:
SUGGESTION & RECOMENDATIONS
/5%
/5%
/5%
/15%
/15%
/20%
/15%
/10%
/5%
REFERENCES:
/5%
TOTAL:
/100%
FACULTY: ENNGINEERING
TECHNOLOGY
LABORATORY: HYDRAULICS
AND HYDROLOGY
EXPERIMENT: INFILTRATION
TEST
EDITION:
REVISION NO:
EFFECTIVE DATE:
AMENDMENT
DATE:
I hereby declare that I have prepared this report with my own efforts. I also admit to
not accept or provide any assistance in preparing this report and anything that is in
it is true.
1) Group Leader
Name
Matrix No.
:
:
2) Group Member 1
Name
Matrix No
:
:
3) Group Member 2
__________________________________________(Signature)
__________________________________
__________________________________
__________________________________________(Signature)
__________________________________
___________________________________
__________________________________________(Signature)
FACULTY: ENNGINEERING
TECHNOLOGY
LABORATORY: HYDRAULICS
AND HYDROLOGY
EXPERIMENT: INFILTRATION
TEST
EDITION:
REVISION NO:
EFFECTIVE DATE:
AMENDMENT
DATE:
1.0 OBJECTIVE
To identify the characteristics of the infiltration rate of water into soils in the field.
.
FACULTY: ENNGINEERING
TECHNOLOGY
LABORATORY: HYDRAULICS
AND HYDROLOGY
EXPERIMENT: INFILTRATION
TEST
EDITION:
REVISION NO:
EFFECTIVE DATE:
AMENDMENT
DATE:
t is the time interval (hour). For the annular space between rings, calculate
V V A /( AA .t ) where V A is the annular space incremental infiltration
as follows; A
velocity (cm/hr), V A is the volume of water used during time interval to maintain
(cm2) and
space (cm2) and t is the time interval (hour). The infiltration rate calculated with the
inner ring should be the value used for results if the rates for the inner ring and
annular space differ. The difference in rates is due to divergent flow.
4.0 EQUIPMENTS
4.1 Two stainless steels rings measure 12 and 24 diameter x 20 high
4.2 Marriotte tube
FACULTY: ENNGINEERING
TECHNOLOGY
LABORATORY: HYDRAULICS
AND HYDROLOGY
EXPERIMENT: INFILTRATION
TEST
EDITION:
REVISION NO:
EFFECTIVE DATE:
AMENDMENT
DATE:
5.0 PROCEDURES
After a test site has been selected and the soil surfafe has been prepared, the outer.
Ring is driven into the soil using s driving cap on the top which a wood block can be used to
absorb the blow from a sledge hammer. The outer ring is inserted by moving the wood block
araound the edge of the driving cap. The ring is inserted to a depth that will (a) prevent the test
water from leaking to the ground surface surrounding the ring, and (b) be deeper than the depth
to which the innner ring will be driven. A depth of about 15cm is usually adequate.
Once the outer ring is in place, the inner ring can be centered inside the large ring
and driven to a depth that will prevent leakage of water the ground surface surrounding the
ring. A depth of about 5-10 cm is usually adequate. Both the outer and the innner ring should
be level. The soil surrounding the wall of the ring (s) should be exempt of excessive disturbance.
In case extensive carcking or heave are observed, the ring (s) should be reset to a different
location using a technique that will minimize such disturbance.
There are three ways to maintain constant head (water lever) within the inner ring
and annular space between the two ring, manually controlling the flow liquid, the use of
constant level float valves, or the use of a mariotte tube. The latter option is the preferred one
since it auto-regulates water flow to the ring. A pair or water bottle is used to fill both rings with
water to the same desired depth in each ring. The water flow from the mariotte tube can than be
initiated. As soon as the fluid level becomes constant, the water level in the inner ring and in the
annular space is measure (and recorded) to the nearest 2mm using a ruler or a tape measure.
The water level is maintained at a selected head (level) in both the inner ring annular space
between rings throughout the test to prevent flow of water from one ring to the other.
The volume of water that is added to maintain a constant head in the inner ring. And
annular space during each timing interval is determined by measuring the change in elevation of
the water level in the appropriate graduated mariotte tube. For average soils, the volume of water
used to maintain the head recorded at every 5 min intervals for at least 6 hours, or until a
relatively costant infiltration rate is achieved. The appropriate reading frenquency may be
determined only through experience and may be more frenquet for high-K meterials
FACULTY: ENNGINEERING
TECHNOLOGY
LABORATORY: HYDRAULICS
AND HYDROLOGY
EXPERIMENT: INFILTRATION
TEST
EDITION:
REVISION NO:
EFFECTIVE DATE:
AMENDMENT
DATE:
Inner
(mm)
Infiltration
Capacity
(mm)
Infiltration Rate
(mm/s)
FACULTY: ENNGINEERING
TECHNOLOGY
LABORATORY: HYDRAULICS
AND HYDROLOGY
EXPERIMENT: INFILTRATION
TEST
EDITION:
REVISION NO:
EFFECTIVE DATE:
AMENDMENT
DATE:
7.0 QUESTIONS
7.1 Plot a graphs of:
a) Infiltration capacity versus time
b) Infiltration rate versus time
7.2 From the graph in 7.1(a), please identify the basic of infiltration rate
7.3 Sketch a graphs of infiltration rate versus time for the three different characteristics
soils:
Dry soil
Wet soil
Saturated soil
Explain each of the graphs
Signature/Tandatangan:
Signature / Tandatangan :
BABA
Date / Tarikh : AUGUST 2016
FACULTY: ENNGINEERING
TECHNOLOGY
LABORATORY: HYDRAULICS
AND HYDROLOGY
EXPERIMENT: INFILTRATION
TEST
EDITION:
REVISION NO:
EFFECTIVE DATE:
AMENDMENT
DATE: