SPECIFICATION
KAPASITY (kW)
300kW
MODEL
GENSET NO.
PLATE NO.
SCANIA
B8
WBM 5852
b. Test fuel
The followings are the test fuels, according to sequence for testing
i. Test fuel #1 : Diesel (Industrial Grade) as baseline fuel
ii. Test fuel #2 : B5 (5% FGB + 95% Diesel)
iii. Test fuel #3 : B10 (10% FGB + 90% Diesel)
iv. Test fuel #4 : B15 (15% FGB + 85% Diesel)
v. Test fuel #5 : S10 (10% SGB + 90% Diesel)
Note :
Anemometer
Flow rate meter (on-site)
Load Bank Test (on-site)
Gas Analyzer
Stopwatch
Drums/ hose (on-site)
D. TEST PROCEDURES
1. Transfer test fuel #1 from storage drum into genset fuel tank. This to be done using facilities
available at refueling station on site
2. Fill up all the Load Bank Test Datasheet (Air Intake, Fuel flow rate, Generator Output and
Emission) with the test details as follows:
a. Genset No
b. Capacity
c. Model number
d. Name of data recorder
e. Date of test
f. Time of test (start)
g. Type of fuel
3. Ensure all instruments for data collection is fitted or ready for data measurement
4. Start the genset and let it run for 5 minutes. Take the readings. This will be the initial reading
without any load
5. Set the load to 60 kW. Observe the measured parameters readings to ensure all instruments
are functioning properly
6. After 5 minutes, take the first reading. Take another reading after 10, 15, 20, 25 and 30
minutes.
7. Increase the load to 120kW and repeat step #6
8. Increase the load to 180kW and repeat step #6
9. Increase the load to 240kW and repeat step#6
10. Increase the load to maximum. Record the maximum load value and all the readings for
measured parameters.
11. End of testing. The genset technician shall proceed with routine steps for test completion.
12. Repeat all the procedures above for all the test fuel.
E. TEST PROCEDURES
The followings are Test Datasheets
: ..
: ..
: ..
: ..
: ..
TIME
(min)
LOAD (kW)
0
60
120
180
240
MAX
240
MAX
5
10
15
20
25
30
B) AIR FLOW TEMPERATURE READINGS
UNIT USED
:
TIME
(min)
LOAD (kW)
0
60
120
5
10
15
20
25
30
180
: ..
: ..
: ..
: ..
: ..
TIME
(min)
LOAD (kW)
0
60
120
5
10
15
20
25
30
180
240
MAX
: ..
: ..
: ..
: ..
: ..
TIME
(min)
:
:
LOAD (kW)
60
0
VOLTAGE
RY
YB
BR
CURRENT
R
Twater
Plube
oil
VOLTAGE
RY
120
CURRENT
YB
UNITS
5
10
15
20
25
30
Twater
Plube
oil
VOLTAGE
RY
YB
BR
CURRENT
R
Twater
Plube
oil
: ..
: ..
: ..
: ..
: ..
TIME
(min)
:
:
LOAD (kW)
240
180
VOLTAGE
RY
YB
BR
CURRENT
R
Twater
Plube
oil
VOLTAGE
RY
MAX
CURRENT
YB
UNITS
5
10
15
20
25
30
Twater
Plube
oil
VOLTAGE
RY
YB
BR
CURRENT
R
Twater
Plube
oil
: ..
: ..
: ..
: ..
: ..
TIME
(min)
EMISSION DATA
60 kW
0 kW
CO2
CO
O2
TEXHAUST
CO2
CO
O2
UNIT
5
10
15
20
25
30
120 kW
TEXHAUST
CO2
CO
O2
TEXHAUST
: ..
: ..
: ..
: ..
: ..
TIME
(min)
EMISSION DATA
240 kW
180 kW
CO2
CO
O2
TEXHAUST
CO2
CO
O2
UNIT
5
10
15
20
25
30
MAX kW
TEXHAUST
CO2
CO
O2
TEXHAUST
2.
3.
Checked by
Verified by
Approved by
10